Commission Delegated Regulation (EU) 2026/557 of 16 March 2026 supplementing Regulation (EU) 2024/3110 of the European Parliament and of the Council by determining classes of performance in relation to the essential characteristic resistance to fire

Issued by European Commission · Directorate-General for Internal Market

Research with AI Agent Chat with Document Generate Summary Translate Helpful Share Add to Project Create Task

Executive Summary & Key Takeaways

**Executive Summary** This Regulation establishes standardized classes of performance for construction products regarding their essential characteristic of resistance to fire, supplementing Regulation (EU) 2024/3110. It defines specific symbols and time-based performance categories (ranging from 15 to 360 minutes) to ensure continuity in the marketing of construction products across the European Union. The Regulation was adopted on 16 March 2026 and enters into force on the twentieth day following its publication in the Official Journal. **Key Points / Main Content** * **Classification Framework and Symbols** * Defines core performance symbols: 'R' (Load-bearing capacity), 'E' (Integrity), 'I' (Insulation), 'W' (Radiation), and 'M' (Mechanical action). * Establishes 'C' for self-closing capability, including durability categories (C0 to C5) based on cycles ranging from ≥ 1 to ≥ 200,000. * Includes specific indicators for smoke leakage ('S'), fire protection ability ('K'), and continuity of power/signal supply ('P' and 'PH'). * **Load-Bearing and Separating Elements** * Sets performance classes for load-bearing elements without fire-separating functions (e.g., beams, columns, balconies) based on duration in minutes. * Provides classifications for load-bearing elements with fire-separating functions (RE, REI, REI-M, REW) applicable to walls, floors, and roofs. * Defines requirements for products protecting structural members, such as fire-protective coatings, claddings, and reactive screens. * **Non-Loadbearing Products and Systems** * Categorizes performance for partitions, fixed windows, and facades using integrity ('E'), insulation ('EI'), and radiation ('EW') metrics. * Specific rules are established for penetration seals, linear joint seals, and air transfer grilles. * Includes requirements for fire-resisting doorsets and openable windows, including smoke control criteria (S200, Sa). * **Building Service Installations** * Classifies fire-resisting ventilation ducts and fire dampers, requiring specific leakage rates ('S') and testing from both sides. * Sets fire resistance standards for electrical, power control, and communication cables, including unprotected cables with intrinsic resistance (Pca, PHca). * Determines classes for service ducts, shafts, and chimneys, including operating temperature designations. * **Smoke and Heat Control Systems** * Defines performance for single and multi-compartment smoke control ducts and dampers. * Establishes classes for smoke barriers ('D' and 'DH') and powered smoke/heat ventilators ('F'). * Categorizes natural smoke and heat exhaust ventilators ('B'), noting they are designed to open in case of fire and do not possess an integrity ('E') classification. **Impact Analysis** **Manufacturers of Construction Products** **Impact:** Manufacturers are required to use these harmonized classes and symbols when declaring the performance of products related to fire resistance. **Action Required:** Align product testing, technical documentation, and declarations of performance with the specific categories and time-durations defined in the Regulation’s Annex. **Testing and Certification Bodies** **Impact:** These organizations must use the updated performance criteria and definitions for assessing construction products. **Action Required:** Update laboratory testing protocols and classification reports to incorporate the specific suffixes and symbols (e.g., 'incSlow', 'sn', 'ef', 've/ho') mandated by the document. **EU Member State Authorities** **Impact:** The Regulation is directly applicable across all Member States, ensuring a uniform system for the marketing of fire-resistant products. **Action Required:** Ensure market surveillance and national building regulations recognize and enforce the performance classes established under this Delegated Regulation.

Key Entities Referenced

Commission Delegated Regulation (EU) 2026/557: The primary regulation determining classes of performance for the fire resistance of construction products to supplement EU marketing rules. Regulation (EU) 2024/3110: The base legislative act laying down harmonised rules for the marketing of construction products and establishing the harmonised zone. Commission Delegated Regulation (EU) 2024/1681: The source document used to establish technical classes of performance for fire resistance to ensure system continuity. CPR Acquis Expert Group: The advisory body that provided guidance to the Commission on establishing fire resistance classes aligned with latest developments.
Official Source Record View Original Source →
See Full Document Text
Official Journal EN of the European Union L series 2026/557 3.6.2026 COMMISSION DELEGATED REGULATION(EU) 2026/557 of 16 March 2026 supplementing Regulation (EU) 2024/3110 of the European Parliament and of the Council by determining classes of performance in relation to the essential characteristic resistance to fire (Text with EEA relevance) THE EUROPEAN COMMISSION, Having regard to the Treaty on the Functioning of the European Union, Having regard to Regulation (EU) 2024/3110 of the European Parliament and of the Council of 27 November 2024 laying down harmonised rules for the marketing of construction products and repealing Regulation (EU) No 305/2011(1), and in particular Article 5(5), third subparagraph thereof, Whereas: (1) In order to enable manufacturers to declare sufficiently detailed classes of performance of products within the harmonised zone established pursuant to Article 11 of Regulation (EU) 2024/3110, it is necessary to establish classes of performance that are aligned to the latest technological and market developments. (2) Classes of performance as regards the essential characteristic resistance to fire were established by Commission Delegated Regulation (EU) 2024/1681(2)on the basis of Regulation (EU) No 305/2011 of the European Parliament and of the Council(3). However, those classes of performance are not applicable under Regulation (EU) 2024/3110. Therefore, in order to keep the continuity of the system, the CPR Acquis Expert Group advised the Commission to establish the same classes of performance set out by Delegated Regulation (EU) 2024/1681. (3) The Commission should therefore determine the classes of performance to be used for the declaration of the essential characteristic resistance to fire, HAS ADOPTED THIS REGULATION: Article 1 The classes of performance in relation to the essential characteristic resistance to fire of products shall be those set out in the Annex. (1) OJ L, 2024/3110, 18.12.2024, ELI: http://data.europa.eu/eli/reg/2024/3110/oj. (2) Commission Delegated Regulation (EU) 2024/1681 of 6 March 2024 supplementing Regulation (EU) No 305/2011 of the European Parliament and of the Council by establishing classes of performance in relation to the resistance to fire of construction products (OJ L, 2024/1681, 13.6.2024, ELI: http://data.europa.eu/eli/reg_del/2024/1681/oj). (3) Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ L 88, 4.4.2011, p. 5, ELI: http://data. europa.eu/eli/reg/2011/305/oj). ELI: http://data.europa.eu/eli/reg_del/2026/557/oj 1/13EN OJ L, 3.6.2026 Article 2 This Regulation shall enter into force on the twentieth day following that of its publication in the Official Journal of the European Union. This Regulation shall be binding in its entirety and directly applicable in all Member States. Done at Brussels, 16 March 2026. For the Commission The President Ursula VON DER LEYEN 2/13 ELI: http://data.europa.eu/eli/reg_del/2026/557/ojEN OJ L, 3.6.2026 ANNEX A.SYMBOLS For the purposes of this Annex, the following symbols apply: R Load-bearing capacity E Integrity I Insulation W Radiation M Mechanical action C Self-closing C0-5 Durability of self-closing: Use category (C) Number of cycles 5 ≥ 200 000 4 ≥ 100 000 3 ≥ 50 000 2 ≥ 10 000 1 ≥ 500 0 ≥ 1 S Smoke leakage (in context of ventilation systems)/Smoke control (in context of doors) P Continuity of power and signal supply under the standard time temperature curve PH Continuity of power and signal supply under constant temperature G/O Soot fire resistance K Fire protection ability T Temperature class expressed in maximum gas temperature in °C (operating temperature) D Stability duration under constant temperature DH Stability duration under the standard time-temperature curve F Functionality of powered smoke and heat ventilators B Functionality of natural smoke and heat ventilators B.CLASSES OF PERFORMANCE IN RELATION TO THE ESSENTIAL CHARACTERISTIC RESISTANCE TO FIRE OF PRODUCTS General The relevant definitions, tests and performance criteria are fully described or referenced in the relevant harmonised technical specifications, European assessment documents, and European resistance to fire classification and testing standards. If for asymmetrical elements the declared class of the element is only valid from one side, this information is provided. ELI: http://data.europa.eu/eli/reg_del/2026/557/oj 3/13EN OJ L, 3.6.2026 The following classes of performance are expressed in minutes unless otherwise specified: 1. Load-bearing elements without a fire-separating function Table 1 Applies to Walls, floors, raised floors, roofs, beams, columns, balconies, walkways and stairs R 15 20 30 45 60 90 120 180 240 360 2. Load-bearing elements with a fire-separating function Table 2.1 Applies to Walls RE 15 20 30 45 60 90 120 180 240 360 REI 15 20 30 45 60 90 120 180 240 360 REI-M 15 20 30 45 60 90 120 180 240 360 REW 15 20 30 45 60 90 120 180 240 360 Table 2.2 Applies to Floors, roofs, roof windows, rooflights and shutters RE 15 20 30 45 60 90 120 180 240 360 REI 15 20 30 45 60 90 120 180 240 360 C The C classification may be declared where a self-closing device is fitted, and the element or product was not manually closed for the purpose of the test. Optionally, for durability of self-closing, the C classification may be complemented by the digits 0 to 5 according to the use category where cycle testing has been carried out. Table 2.3 Applies to Raised floors RE 15 20 30 45 60 90 120 180 240 360 REI 15 20 30 45 60 90 120 180 240 360 Notes The classification is made specific depending on the exposure. The absence of the designation letter ‘r’ refers to standard temperature/time curve exposure (full fire resistance) whereas its presence refers to the constant temperature attack of 500 °C (reduced exposure). Raised floors satisfying the standard temperature/time curve exposure for a given time are considered to satisfy the reduced exposure conditions for at least the same period. 3. Products and systems for protecting load-bearing elements Table 3.1 Applies to Ceilings with no independent fire resistance Assessment of the contribution to the fire resistance of structural members: Expressed in terms of classification of the load-bearing element being protected. Notes Where the criteria with regard to the ‘semi-natural’ fire are satisfied, the symbol ‘sn’ is added to the classification. 4/13 ELI: http://data.europa.eu/eli/reg_del/2026/557/ojEN OJ L, 3.6.2026 Table 3.2 Applies to Fire protective coatings (reactive), boards (slabs and mats), renderings (sprays), claddings and screens Assessment of the contribution to the fire resistance of structural members: Expressed in terms of classification of the load-bearing element being protected. Notes For coatings, if satisfying the criteria with regard to the ‘slow heating’ curve, the symbol ‘IncSlow’ is added to the classification. 4. Non-loadbearing elements or products with a fire-separating function Table 4.1 Applies to Partitions (including partitions incorporating uninsulated portions) and fixed windows E 15 20 30 45 60 90 120 180 240 360 EI 15 20 30 45 60 90 120 180 240 360 EI-M 15 20 30 45 60 90 120 180 240 360 EW 15 20 30 45 60 90 120 180 240 360 Table 4.2 Applies to Unloaded roofs E 15 20 30 45 60 90 120 180 240 360 EI 15 20 30 45 60 90 120 180 240 360 EW 15 20 30 45 60 90 120 180 240 360 Table 4.3 Applies to Cavity barriers E 15 20 30 45 60 90 120 180 240 360 EI 15 20 30 45 60 90 120 180 240 360 Notes The classification is completed by a separate indication, if the product satisfies the sudden exposure test for cavity barriers. Table 4.4 Applies to Ceilings with independent fire resistance EI 15 20 30 45 60 90 120 180 240 360 Notes The classification is completed by indicating how the element has been tested, and refers to a fire from above ‘(a→b)’ or from below ‘(b→a)’ or both ‘(a↔b)’. ELI: http://data.europa.eu/eli/reg_del/2026/557/oj 5/13EN OJ L, 3.6.2026 Table 4.5 Applies to Facades (curtain walls) and external walls (including glazed elements) E 15 20 30 45 60 90 120 180 240 360 EI 15 20 30 45 60 90 120 180 240 360 EW 15 20 30 45 60 90 120 180 240 360 Notes The classification is completed by ‘(i→o)’; ‘(o→i)’; or ‘(i↔o)’ to indicate whether the element has been tested and fulfils the requirements from the inside only; from the outside only; or from both sides respectively. The addition of the suffix ‘ef’ indicates that the test was performed on the basis of the external fire curve. Table 4.6 Applies to Non-mechanical fire barriers for ventilation ductwork E 15 20 30 45 60 90 120 180 240 360 EI 15 20 30 45 60 90 120 180 240 360 Notes In addition to meeting the requirements related to integrity (E), the non-mechanical fire barrier must also: (a) be tested from both sides; and (b) achieve 360 m3/(m2h) maximum leakage rate with reference to nominal duct cross-sectional area during the fire test. There is no S classification for this product, as it has no ambient temperature smoke performance. ‘ve’ and/or ‘ho’ indicate that the product is intended to be used for vertical and/or horizontal use. Table 4.7 Applies to Penetration seals E 15 20 30 45 60 90 120 180 240 360 EI 15 20 30 45 60 90 120 180 240 360 Notes The classification is expressed in terms of classification of the supporting construction with fire- separating function being penetrated. The classification of pipe penetration seals is completed by the addition of ‘U/U’, ‘C/U’, ‘U/C’, or ‘C/C’ depending on the tested pipe end configuration inside the furnace and outside the furnace respectively (U – uncapped; C – capped). Table 4.8 Applies to Combined penetration seals E 15 20 30 45 60 90 120 180 240 360 EI 15 20 30 45 60 90 120 180 240 360 Notes The classification is expressed in terms of classification of the supporting construction with fire- separating function being penetrated. The classification is completed with the additional relevant classifications of combined elements as set out in this Annex. 6/13 ELI: http://data.europa.eu/eli/reg_del/2026/557/ojEN OJ L, 3.6.2026 Table 4.9 Applies to Linear joint seals E 15 20 30 45 60 90 120 180 240 360 EI 15 20 30 45 60 90 120 180 240 360 Notes The classification is completed by the addition of the symbols: — ‘H’, or ‘V’, or ‘T’ indicating that the classification is valid for the corresponding orientation (Horizontal supporting construction; Vertical supporting construction – vertical joint; Vertical supporting construction – horizontal joint respectively); — ‘M’, or ‘F’, or ‘B’ indicating the type of splices (Manufactured; Field; or Both manufactured and field respectively); — ‘X’, or ‘Mxxx’ indicating the movement capability (No movement; or Movement induced (in %) respectively), including the subscript ‘lat’ or ‘shear’ indicating the induced movement; — ‘W w1 to w2’ indicating the joint width range (in mm) for which the classification criterion is satisfied (w1 being the lower width and w2 the higher width limit). Table 4.10 Fire resisting doorsets, openable windows (in walls and roofs), openable rooflights and shutters (including those Applies to that incorporate glazing, closing devices and other building hardware) E 15 20 30 45 60 90 120 180 240 360 EI 15 20 30 45 60 90 120 180 240 360 EW 15 20 30 45 60 90 120 180 240 360 S For elements and products having passed smoke control criteria depending on test conditions fulfilled. 200 S or S For elements and products having passed smoke control criteria depending on test conditions fulfilled. a3 a4 C The C classification may be declared where a self-closing device is fitted and the element or product was not manually closed for the purpose of the test. Optionally, for durability of self-closing, the C classification may be complemented by the digits 0 to 5 according to the use category where cycle testing has been carried out. Notes The EI classification is completed by the addition of the suffix ‘1’ or ‘2’ to indicate which definition of insulation is used. In the case where the classification does not cover heating on both the closing and the opening face, it must be indicated explicitly in the classification. This table does not include or address products for smoke ventilation. Additional smoke control classification of large industrial doorsets is possible to a leakage limit of 50 m3/h. Table 4.11 Applies to Closures for conveyers and track bound transportation systems E 15 20 30 45 60 90 120 180 240 360 EI 15 20 30 45 60 90 120 180 240 360 EW 15 20 30 45 60 90 120 180 240 360 ELI: http://data.europa.eu/eli/reg_del/2026/557/oj 7/13EN OJ L, 3.6.2026 Applies to Closures for conveyers and track bound transportation systems C The C classification may be declared where a self-closing device is fitted and the element or product was not manually closed for the purpose of the test. Optionally, for durability of self-closing, the C classification may be complemented by the digits 0 to 5 according to the use category where cycle testing has been carried out. Notes The EI classification is completed by the addition of the suffix ‘1’ or ‘2’ to indicate which definition of insulation is used. An EI classification must be generated in cases where the test specimen is a pipe or duct configuration with no assessment of the closure for the conveyor system. Sustained operational capability of any clearing device and/or any separating device for a conveyor system is identified by using a ‘T’. Table 4.12 Applies to Air transfer grilles E 15 20 30 45 60 90 120 180 240 360 EI 15 20 30 45 60 90 120 180 240 360 EW 15 20 30 45 60 90 120 180 240 360 Notes If satisfying the criteria with regard to integrity during the open state, the symbol ‘resist flame’ is added to the classification. If satisfying the criteria with regard to the ‘smouldering’ curve, the symbol ‘IncSlow’ is added to the classification. Table 4.13 Applies to Service ducts and shafts E 15 20 30 45 60 90 120 180 240 360 EI 15 20 30 45 60 90 120 180 240 360 Notes The classification indicates how the element has been tested and refers to a fire from the inside ‘(i→o)’ or from the outside ‘(o→i)’ or both ‘(i↔o)’. In addition, the symbols ‘ve’ and/or ‘ho’ indicate that the product is intended to be used for vertical and/or horizontal use. Table 4.14 Applies to Chimneys G + distance in mm (e.g. G 50) or O + distance in mm (e.g. O 50) E 15 20 30 45 60 90 120 180 240 360 EI 15 20 30 45 60 90 120 180 240 360 T (operating 80 100 120 140 160 200 250 300 400 450 600 temperature) in °C Notes Distance not required for built-in products. The classification indicates how the element has been tested and refers to a fire from the outside ‘(o→i)’ or both ‘(i↔o)’. ‘ve’ and/or ‘ho’ indicate that the product is intended to be used for vertical and/or horizontal use. 8/13 ELI: http://data.europa.eu/eli/reg_del/2026/557/ojEN OJ L, 3.6.2026 Table 4.15 Applies to Wall and ceiling coverings K 10 15 20 30 45 60 90 120 180 240 360 1 K 10 15 20 30 45 60 90 120 180 240 360 2 Notes The suffixes ‘1’ and ‘2’ indicate which substrates, fire behaviour criteria and extension rules are used in this classification. 5. Products for use in ventilation systems (excluding smoke and heat exhaust ventilation) Table 5.1 Applies to Fire resisting ventilation ducts E 15 20 30 45 60 90 120 180 240 360 EI 15 20 30 45 60 90 120 180 240 360 S 10 m3/(m2h) maximum leakage rate with reference to the duct surface area during the fire test. Notes In addition to meeting the requirements related to integrity (E) the duct must also achieve 15 m3/(m2h) maximum leakage rate with reference to duct surface area during the fire test. The classification indicates how the element has been tested and refers to a fire from the inside ‘(i→o)’ or from the outside ‘(o→i)’ or both ‘(i↔o)’. ‘ve’ and/or ‘ho’ indicate that the product is intended to be used for vertical and/or horizontal use. The classification must indicate the pressure difference used in the test. Table 5.2 Applies to Fire dampers E 15 20 30 45 60 90 120 180 240 360 EI 15 20 30 45 60 90 120 180 240 360 S 200 m3/(m2h) maximum leakage rate with reference to nominal duct cross sectional area: (a) smallest size at ambient temperature; (b) largest size at ambient temperature and during the fire test. Notes In addition to meeting the requirements related to integrity (E) the fire damper must also: (a) be tested from both sides; and (b) achieve 360 m3/(m2h) maximum leakage rate with reference to nominal duct cross sectional area during the fire test. ‘ve’ and/or ‘ho’ indicate that the product is intended to be used for vertical (for example, wall mounted) and/or horizontal (for example, floor mounted) use. ‘H’ indicates a fire damper capable of satisfying integrity (E), or integrity and insulation (EI) for the classification period having a horizontal blade axis or geometry. ‘V’ indicates a fire damper capable of satisfying integrity (E), or integrity and insulation (EI) for the classification period having a vertical blade axis or geometry. ELI: http://data.europa.eu/eli/reg_del/2026/557/oj 9/13EN OJ L, 3.6.2026 6. Products to be used within electrical, power control and communication building service installations Table 6.1 Applies to Fire protective systems for cable systems and associated components P 15 20 30 45 60 90 120 180 240 360 Notes The classification must indicate: The type of cables which can be installed within the fire protective systems, that is to say any standard cable or only specific cables; and the cables configurations which can be protected and the operating voltage as follows: — either to all types of power cables (rated voltage 300/500 V) for an operating voltage up to 230/400 V (three-phase AC); — either to all types of power cables (rated voltage 450/750 V up to 0,6/1 kV) for an operating voltage up to 400/690 V (Three-phase AC); — either to all types of signal-/control cables (rated voltage up to 170 V) for an operating voltage up to 110 V; or — any combination of the above possibilities. Table 6.2 Applies to Unprotected electric, power control and communication cables with intrinsic fire resistance P 15 20 30 45 60 90 120 180 240 360 ca Notes For power cables and control cables, the classification must indicate for which rated voltage the performance criteria are satisfied. Table 6.3 Unprotected small electric, power control and communication cables with intrinsic fire resistance (< 20 mm Applies to diameter and with conductor sizes ≤ 2,5 mm2) PH 15 20 30 45 60 90 120 180 240 360 ca Notes For power cables and control cables, the classification must indicate for which rated voltage the performance criteria are satisfied. 7. Products to be used in smoke and heat control systems Table 7.1 Applies to Single compartment smoke control ducts E 15 20 30 45 60 90 120 180 240 360 600 S 5 m3/(m2h) maximum leakage rate with reference to duct surface area at ambient temperature and 5 m3/(m2h) maximum leakage rate related to the duct surface area during the fire test. Notes In addition to meeting the requirements related to integrity (E) the duct must also achieve 10 m3/(m2h) maximum leakage rate with reference to duct surface area during the fire test. The classification is completed by the suffix ‘single’ for products intended to be used for single compartment use only. ‘ve’ and/or ‘ho’ indicate that the product is intended to be used for vertical and/or horizontal use, within the compartment. ‘500’, ‘1 000’, ‘1 500’ indicate the product is intended to be used up to these values of under-pressure, measured in Pa at ambient temperature. 10/13 ELI: http://data.europa.eu/eli/reg_del/2026/557/ojEN OJ L, 3.6.2026 Table 7.2 Applies to Multi-compartment fire resistant smoke control ducts E 15 20 30 45 60 90 120 180 240 360 EI 15 20 30 45 60 90 120 180 240 360 S 5 m3/(m2h) maximum leakage rate with reference to duct surface area at ambient temperature and 5 m3/(m2h) maximum leakage rate related to the duct surface area during the fire test. Notes In addition to meeting the requirements related to integrity (E) the duct must also achieve 10 m3/(m2h) maximum leakage rate with reference to duct surface area during the fire test. The classification is completed by the suffix ‘multi’ for products intended to be used for multi- compartment use. ‘ve’ and/or ‘ho’ indicate that the product is intended to be used for vertical and/or horizontal use. ‘500’, ‘1 000’, ‘1 500’ indicate that the product is intended to be used up to these values of under- pressure, measured in Pa at ambient temperature. Table 7.3 Applies to Single compartment smoke control dampers E 15 20 30 45 60 90 120 180 240 360 600 S 200 m3/(m2h) maximum leakage rate with reference to nominal duct cross sectional area: (a) smallest size at ambient temperature; (b) largest size at ambient temperature and during the fire test. Notes In addition to meeting the requirements related to integrity (E) the single compartment smoke control damper must also: (a) be tested from both sides; (b) pass a maintenance of opening test; and (c) achieve 360 m3/(m2h) maximum leakage rate with reference to nominal duct cross sectional area during the fire test (1) smallest size at ambient temperature; and (2) largest size at ambient temperature and during the fire test. The classification is completed by the suffix ‘single’ for products intended for single compartment use. ‘ved’, ‘vew’, ‘vedw’ and/or ‘hod’, ‘how’, ‘hodw’ indicate that the product is intended to be used for vertical and/or horizontal use, together with mounting in a duct or in a wall/floor or both respectively. ‘H’ indicates a single compartment smoke control damper capable of satisfying integrity (E) for the classification period having a horizontal blade axis or geometry, ‘V’ indicates a single compartment smoke control damper capable of satisfying integrity (E) for the classification period having a vertical blade axis or geometry. ‘500’, ‘1 000’ and ‘1 500’ indicate that the product is intended to be used up to this value of under- pressure in Pa at ambient temperature. ‘AA’ denotes for use with applications providing automatic activation, ‘MA’ denotes for use with applications requiring manual intervention or providing automatic activation. ‘C ’, ‘C ’, ‘C ’ or ‘C (N)’, ‘C (N)’, ‘C (N)’ indicate the product is intended to be used in 300 10 000 MOD 300 10 000 MOD smoke control only systems, fully controlled smoke control systems and smoke control systems combined with environmental systems or modulating smoke control dampers intended to be used in any system having a controlled or variable position, tested under load, or without load (N), respectively. ‘HOT 400/30’ (High Operational Temperature) indicates that the single compartment smoke control damper has been subjected to an additional test to demonstrate that it has the ability to be opened and closed during a period of 30 minutes of temperatures up to 400 °C. ELI: http://data.europa.eu/eli/reg_del/2026/557/oj 11/13EN OJ L, 3.6.2026 Table 7.4 Applies to Multi-compartment fire resistant smoke control dampers E 15 20 30 45 60 90 120 180 240 360 EI 15 20 30 45 60 90 120 180 240 360 S 200 m3/(m2h) maximum leakage rate with reference to nominal duct cross sectional area: (a) smallest size at ambient temperature; (b) largest size at ambient temperature and during the fire test. Notes In addition to meeting the requirements related to integrity (E) or integrity and insulation (EI) the multi-compartment fire resistant smoke control damper must also: (a) be tested from both sides; (b) pass a maintenance of opening test; and (c) achieve 360 m3/(m2h) maximum leakage with reference to nominal duct cross sectional area during the fire test (1) smallest size at ambient temperature; and (2) largest size at ambient temperature and during the fire test. The classification is completed by the suffix ‘multi’ for products intended for multi-compartment use. ‘ved’, ‘vew’, ‘vedw’ and/or ‘hod’, ‘how’, ‘hodw’ indicate that the product is intended to be used for vertical and/or horizontal use, together with mounting in a duct or in a wall/floor or both respectively. ‘H’ indicates a multi-compartment fire resistant smoke control damper capable of satisfying integrity (E), or integrity and insulation (EI) for the classification period having a horizontal blade axis or geometry. ‘V’ indicates a multi-compartment fire resistant smoke control damper capable of satisfying integrity (E), or integrity and insulation (EI) for the classification period having a vertical blade axis or geometry. ‘500’, ‘1 000’ and ‘1 500’ indicate that the product is intended to be used up to this value of under- pressure in Pa at ambient temperature. ‘AA’ denotes for use with applications providing automatic activation, ‘MA’ denotes for use with applications requiring manual intervention or providing automatic activation. ‘C ’, ‘C ’, ‘C ’ or ‘C (N)’, ‘C (N)’, ‘C (N)’ indicate that the product is intended to be used 300 10 000 MOD 300 10 000 MOD in smoke control only systems, fully controlled smoke control systems and smoke control systems combined with environmental systems or modulating smoke control dampers intended to be used in any system having a controlled or variable position, tested under load, or without load (N), respectively. ‘HOT 400/30’ (High Operational Temperature) indicates that the multi-compartment fire resistant smoke control damper has been subjected to an additional test to demonstrate that it has the ability to be opened and closed during a period of 30 minutes of temperatures up to 400 °C. Table 7.5 Applies to Smoke barriers D 15 20 30 45 60 90 120 180 240 360 600 DH 15 20 30 45 60 90 120 180 240 360 12/13 ELI: http://data.europa.eu/eli/reg_del/2026/557/ojEN OJ L, 3.6.2026 Table 7.6 Applies to Powered smoke and heat control ventilators (fans), including connectors F 15 20 30 45 60 90 120 180 240 360 200 F 15 20 30 45 60 90 120 180 240 360 300 F 15 20 30 45 60 90 120 180 240 360 400 F 15 20 30 45 60 90 120 180 240 360 600 F 15 20 30 45 60 90 120 180 240 360 842 Table 7.7 Applies to Natural smoke and heat exhaust ventilators B 15 20 30 45 60 90 120 180 240 360 300 B 15 20 30 45 60 90 120 180 240 360 600 Β 15 20 30 45 60 90 120 180 240 360 θ Notes Where θ indicates the exposure condition (temperature), higher than 300 °C. These products are designed to open in case of fire and do not have an integrity (E) classification. ELI: http://data.europa.eu/eli/reg_del/2026/557/oj 13/13

Continue your research