See Full Document Text
L 49/24 EN Official Journal of the European Union 20.2.2019
Only the original UN/ECE texts have legal effect under international public law. The status and date of entry into force of this Regulation
should be checked in the latest version of the UN/ECE status document TRANS/WP.29/343, available at:
http://www.unece.org/trans/main/wp29/wp29wgs/wp29gen/wp29fdocstts.html
Regulation No 123 of the Economic Commission for Europe of the United Nations (UN/ECE) —
Uniform provisions concerning the approval of adaptive front-lighting systems (AFS) for motor
vehicles [2019/273]
Incorporating all valid text up to:
Supplement 9 to the 01 series of amendments — Date of entry into force: 10 February 2018
CONTENTS
REGULATION
A. ADMINISTRATIVE PROVISIONS
1. Definitions
2. Application for approval of a system
3. Markings
4. Approval
B. TECHNICAL REQUIREMENTS FOR SYSTEMS OR PART(S) OF A SYSTEM
5. General specifications
6. Illumination
7. Colour
C. FURTHER ADMINISTRATIVE PROVISIONS
8. Modification of the system type and extension of approval
9. Conformity of production
10. Penalties for non-conformity of production
11. Production definitively discontinued
12. Names and addresses of Technical Services responsible for conducting approval tests and of Type Approval
Authorities
13. Transitional provisions
ANNEXES
1. Communication
2. Examples of arrangements of approval marks
3. Passing-beam photometric requirements
4. Tests for stability of photometric performance of systems in operation — Tests on complete systems
5. Minimum requirements for conformity of production control procedures
6. Requirements for systems incorporating lenses of plastic material: testing of lens or material samples and complete
systems or part(s) of systems
7. Minimum requirements for sampling by an inspector
8. Passing-beam ‘cut-off’ and aiming provisions
9. Photometric measurement provisions
10. Description forms
11. Requirements for LED modules and adaptive front-lighting (AFS) including LED modules20.2.2019 EN Official Journal of the European Union L 49/25
A. ADMINISTRATIVE PROVISIONS
SCOPE
This Regulation applies to adaptive front-lighting systems (AFS) for motor vehicles of categories M and N (1).
1. DEFINITIONS
For the purpose of this Regulation:
1.1. The definitions given in Regulation No 48 and its series of amendments in force at the time of application
for type approval shall apply;
1.2. ‘Adaptive front-lighting system’ (or ‘system’) means a lighting device, providing beams with differing charac
teristics for automatic adaptation to varying conditions of use of the dipped-beam (passing-beam) and, if it
applies, the main-beam (driving-beam) with a minimum functional content as indicated in paragraph 6.1.1;
such systems consist of the ‘system control’, one or more ‘supply and operating device(s)’, if any, and the
‘installation units’ of the right and of the left side of the vehicle;
1.3. ‘Class’ of a passing-beam (C, V, E or W) means the designation of a passing-beam, identified by particular
provisions according to this Regulation and Regulation No 48 (2);
1.4. ‘Mode’ of a front-lighting function provided by a system means a beam within the provisions (see
paragraphs 6.2 and 6.3 of this Regulation) either for one of the passing-beam classes or for the main beam,
designed and specified by the manufacturer for adaptation to dedicated vehicle and ambient conditions;
1.4.1. ‘Bending mode’ means the designation of a mode of a front-lighting function with its illumination being
laterally moved or modified (to obtain an equivalent effect), designed for bends, curves or intersections of the
road, and, identified by particular photometric provisions;
1.4.2. ‘Category 1 bending mode’ means a bending mode with horizontal movement of the kink of the cut-off;
1.4.3. ‘Category 2 bending mode’ means a bending mode without horizontal movement of the kink of the cut-off;
1.5. ‘Lighting unit’ means a light emitting part of the system, which may consist of optical, mechanical and
electrical components, designed to provide or contribute to the beam of one or more front-lighting
function(s) provided by the system;
1.6. ‘Installation unit’ means an indivisible housing (lamp body) which contains one or more lighting unit(s);
1.7. ‘Right side’ respectively ‘left side’ means the combined total of the lighting units intended to be installed to
that side of the longitudinal median plane of the vehicle, relative to its forward motion;
1.8. ‘System control’ means that part(s) of the system receiving the signals from the vehicle and controlling the
operation of the lighting units automatically;
1.9. ‘Neutral state’ means the state of the system when a defined mode of the Class C passing-beam (‘basic
passing-beam’) or of the main beam, if any, in the maximum condition of activation is produced, and no AFS
control signal applies;
1.10. ‘Signal’ means any AFS control signal as defined in Regulation No 48 or, any additional control input to the
system or, a control output from the system to the vehicle;
1.11. ‘Signal generator’ means a device, reproducing one or more of the signals for system tests;
1.12. ‘Supply and operating device’ means one or more components of a system providing power to one or more
parts of the system, including such as power and/or voltage control(s) for one or more light sources as e.g.
electronic light source control gears;
1.13. ‘System reference axis’ means the intersection line of the vehicle's longitudinal median plane with the
horizontal plane through the centre of reference of one lighting unit specified in the drawings according to
paragraph 2.2.1 below;
(1) As defined in the Consolidated Resolution on the Construction of Vehicles (R.E.3.), document ECE/TRANS/WP.29/78/Rev.2, para. 2. —
www.unece.org/trans/main/wp29/wp29wgs/wp29gen/wp29resolutions.html
(2) For explanation only. The provisions of the passing-beam classes are dedicated to conditions as follows: C for the basic passing-beam,
V for use in lit areas such as towns, E for use on roads such as motorways, W for use in adverse conditions such as wet road.L 49/26 EN Official Journal of the European Union 20.2.2019
1.14. ‘Lens’ means the outermost component of an installation unit, which transmits light through the illuminating
surface;
1.15. ‘Coating’ means any product(s) applied in one or more layers to the outer face of a lens;
1.16. ‘Systems of different types’ means systems which differ in such essential respects as:
1.16.1. The trade name or mark(s):
(a) Lamps bearing the same trade name or mark but produced by different manufacturers shall be considered
as being of different types;
(b) Lamps produced by the same manufacturer differing only by the trade name or mark shall be considered
as being of the same type.
1.16.2. The inclusion or elimination of components capable of altering optical characteristics/photometric properties
of the system;
1.16.3. Suitability for right-hand or left-hand traffic or for both traffic systems;
1.16.4. The front-lighting function(s), mode(s) and classes produced;
1.16.5. The characteristic(s) of the signal(s), specified for the system.
1.17. ‘Aiming’ means the positioning of the beam or part thereof on an aiming screen according to the relevant
criteria;
1.18. ‘Adjustment’ means the use of the means provided by the system for vertical and/or horizontal aiming of the
beam;
1.19. ‘Traffic-change function’ means any front-lighting function or a mode thereof, or part(s) thereof only, or any
combination of these, intended to avoid glare and provide sufficient illumination in case where a vehicle
being equipped with a system designed for one traffic direction only is temporarily used in a country with
the opposite direction of traffic;
1.20. ‘Substitute function’ means any specified front-lighting and/or front light-signalling, be it a front-lighting
and/or a front light-signalling function, or a mode thereof, or part(s) thereof only, or any combination of it,
intended to replace a front-lighting function/mode in case of failure;
1.21. References made in this Regulation to standard (étalon) filament lamp(s) and gas-discharge light source(s)
shall refer to Regulations Nos 37 and 99 respectively, and to their series of amendments in force at the time
of application for type approval.
2. APPLICATION FOR APPROVAL OF A SYSTEM
2.1. The application for approval shall be submitted by the owner of the trade name or mark or by his duly
accredited representative.
It shall specify:
2.1.1. The front-lighting functions, which are intended to be provided by the system, for which Approval is sought
according to this Regulation;
2.1.1.1. Any other front-lighting or front light signalling function(s), provided by any lamp(s) being grouped,
combined or reciprocally incorporated to the lighting units of the system, for which approval is sought;
sufficient information for identification of the respective lamp(s) and indication of the Regulation(s),
according to which they are intended to be (separately) approved;
2.1.2. Whether the passing-beam is designed for both left-hand and right-hand traffic or for either left-hand or
right-hand traffic only;
2.1.3. If the system is equipped with one or more adjustable lighting unit(s):
2.1.3.1. The mounting position(s) of the respective lighting unit(s) in relation to the ground and the longitudinal
median plane of the vehicle;
2.1.3.2. The maximum angles above and below the normal position(s) which the device(s) for vertical adjustment can
achieve;
2.1.4. The category, as listed in Regulation No 37 or 99 and their series of amendments in force at the time of the
application for type approval, of replaceable and/or non-replaceable filament or gas discharge light source(s)
used and/or the light source module specific identification code(s) for LED modules, if available;20.2.2019 EN Official Journal of the European Union L 49/27
2.1.5. If the system is equipped with one or more non-replaceable light source(s):
2.1.5.1. Identification of the lighting unit(s) of which said light source(s) is/are a non-replaceable part;
2.1.6. The operation conditions e.g. different input voltages according to the provisions of the Annex 9 to this
Regulation, if applicable;
2.1.7. If the system is designed to provide an adaptive driving-beam;
2.2. Every application for approval shall be accompanied by:
2.2.1. Drawings in triplicate in sufficient detail to permit identification of the type, showing the position(s) intended
for the approval number(s) and the additional symbols in relation to the circle(s) of the approval mark(s), and
showing in what geometrical position the lighting units are to be mounted on the vehicle in relation to
ground and vehicle longitudinal median plane, and showing each of them in vertical (axial) section and in
front elevation, with main details of the optical design including the axis/axes of reference and the point(s) to
be taken as centre(s) of reference in the tests and any optical features, of the lens, if applicable;
If applicable and in case of LED module(s) also the space(s) reserved for the specific identification code(s) of
the module(s);
2.2.2. A concise technical description of the system specifying:
(a) The lighting function(s) and their modes to be provided by the system (3);
(b) The lighting units contributing to each of them (3) and the signals (4) with the technical characteristics
relevant to their operation;
(c) Which categories (3) of the bending mode requirements apply, if any;
(d) Which additional data set(s) of Class E passing-beam provisions according to Table 6 of Annex 3 to this
Regulation apply, if any;
(e) Which set(s) of Class W passing-beam provisions according to Annex 3 to this Regulation apply, if any;
(f) Which lighting units (4) provide or contribute to one or more passing-beam cut-off(s);
(g) The indication(s) (3) according to the provisions of paragraph 6.4.6 of this Regulation with respect to the
paragraphs 6.22.6.1.2.1 of Regulation No 48;
(h) Which lighting units are designed to provide the minimum passing-beam illumination according to the
paragraph 6.2.8.1 of this Regulation;
(i) Mounting and operation specifications for test purposes;
(j) Any other relevant information;
(k) In the case of LED module(s) this shall include:
(i) A brief technical specification of the LED module(s);
(ii) A drawing with dimensions and the basic electrical and photometric values and the objective
luminous flux and for each LED module a statement whether it is replaceable or not;
(iii) In case of electronic light source control gear, information on the electrical interface necessary for
approval testing;
(l) In the case of adaptation of the driving-beam, which lighting units (4) provide or contribute to the
gradual adaptation of the driving-beam and of the sensor system along with the technical characteristics
relevant to their operation.
2.2.2.1. The safety concept as laid down in the documentation, which, to the satisfaction of the Technical Service
responsible for type approval tests:
(a) Describe the measures designed into the system to ensure compliance with the provisions of para
graphs 5.7.3, 5.9, 6.2.5.4 below, and
(3) To be indicated in a form conforming to the model of Annex 1.
(4) To be indicated in a form conforming to the model of Annex 10.L 49/28 EN Official Journal of the European Union 20.2.2019
(b) Indicates the instructions for their verification according to paragraph 6.2.7 below; and/or
(c) Gives access to the relevant documents demonstrating the system's performance concerning sufficient
reliability and safe operation of the measures specified according to the subparagraph 2.2.2.1(a) above,
e.g. FMEA (‘Failure Mode and Effect Analysis’), FTA (‘Fault Tree Analysis’) or any similar process
appropriate to system safety considerations.
2.2.2.2. The make and type of supply and operating device(s), if any and if not being part of an installation unit;
2.2.3. One set of samples of the system, for which approval is sought, including the mounting devices, supply and
operating devices, and signal generators if any;
2.2.4. For the test of plastic material of which the lenses are made:
2.2.4.1. Fourteen lenses;
2.2.4.1.1. Ten of these lenses may be replaced by 10 samples of material at least 60 × 80 mm in size, having a flat or
convex outer surface and a substantially flat area (radius of curvature not less than 300 mm) in the middle
measuring at least 15 × 15 mm;
2.2.4.1.2. Every such lens or sample of material shall be produced by the method to be used in mass production;
2.2.4.2. A lighting element or optical assembly, if applicable, to which the lenses can be fitted in accordance with the
manufacturer's instructions;
2.2.5. For testing the resistance of the light transmitting components made of plastic material against UV radiation
of those light source(s) inside the system, which can emit UV radiation as e.g. gas discharge light sources,
LED modules, according to paragraph 2.2.4 of Annex 6 to this Regulation:
One sample of each relevant material being used in the system or one system or part(s) thereof, containing
these. Each material sample shall have the same appearance and surface treatment, if any, as intended for use
in the system to be approved;
2.2.6. The materials making up the lenses and coatings, if any, shall be accompanied by the test report of the
characteristics of these materials and coatings if they have already been tested;
2.2.7. In the case of a type of lamp differing only by the trade name or mark from a type that has already been
approved it shall be sufficient to submit:
2.2.7.1. A declaration by the lamp manufacturer that the type submitted is identical (except in the trade name or
mark) with and has been produced by the same manufacturer as, the type already approved, the latter being
identified by its approval code;
2.2.7.2. Two samples bearing the new trade name or mark or equivalent documentation.
2.2.8. In case of a system according to paragraph 4.1.7 below, a vehicle representative of the vehicle(s) indicated
according to paragraph 4.1.6 below.
3. MARKINGS
3.1. The installation units of a system submitted for approval shall bear the trade name or mark of the applicant.
3.2. They shall comprise each, on the lenses and on the main bodies spaces of sufficient size for the approval
mark and the additional symbols referred to in paragraph 4; these spaces shall be indicated on the drawings
referred to in paragraph 2.2.1 above.
3.2.1. If however the lens cannot be detached from the main body of the installation unit, one marking as per
paragraph 4.2.5 shall be sufficient.
3.3. The installation units or systems designed to satisfy the requirements both of right-hand and of left-hand
traffic shall bear markings indicating the two settings of the optical element(s) on the vehicle or of the light
source(s) on the reflector(s); these markings shall consist of the letters ‘R/D’ for the position for right-hand
traffic and the letters ‘L/G’ for the position for left-hand traffic.
3.4. In the case of an AFS with LED module(s), the corresponding installation unit(s) shall bear the marking of the
rated voltage and rated wattage and the light source module specific identification code.
3.5. LED module(s) submitted along with the approval of the AFS:
3.5.1. Shall bear the trade name or mark of the applicant. This marking shall be clearly legible and indelible;20.2.2019 EN Official Journal of the European Union L 49/29
3.5.2. Shall bear the specific identification code of the module. This marking shall be clearly legible and indelible.
This specific identification code shall comprise the starting letters ‘MD’ for ‘MODULE’ followed by the
approval marking without the circle as prescribed in paragraph 4.2.1 below and in the case several non-
identical light source modules are used, followed by additional symbols or characters. This specific identifi
cation code shall be shown in the drawings mentioned in paragraph 2.2.1 above. The approval marking does
not have to be the same as the one on the lamp in which the module is used, but both markings shall be
from the same applicant.
3.5.3. If the LED module(s) are non-replaceable, the markings for LED module(s) are not required.
3.6. If an electronic light source control gear which is not part of a LED module is used to operate a LED
module(s), it shall be marked with its specific identification code(s), the rated input voltage and wattage.
4. APPROVAL
4.1. General
4.1.1. If all the samples of a type of a system submitted pursuant to paragraph 2 above satisfy the provisions of this
Regulation, approval shall be granted.
4.1.2. Where lamps being grouped, combined or reciprocally incorporated with the system satisfy the requirements
of more than one Regulation, a single international approval mark may be affixed provided that each of the
grouped, combined or reciprocally incorporated lamps satisfies the provisions applicable to it.
4.1.3. An approval number shall be assigned to each type approved. Its first two digits shall indicate the series of
amendments incorporating the most recent major technical amendments made to the Regulation at the time
of issue of the approval. The same Contracting Party may not assign the same number to another type of
system covered by this Regulation.
4.1.4. Notice of approval or of extension or refusal or withdrawal of approval or production definitively
discontinued of a type of system pursuant to this Regulation shall be communicated to the Parties to the
1958 Agreement applying this Regulation, by means of a form conforming to the model in Annex 1 to this
Regulation, with the indications according to paragraph 2.1.3.
4.1.4.1. If the installation unit(s) is/are equipped with an adjustable reflector and if this/these installation unit(s) is/are
to be used only in mounting positions according to the indications in paragraph 2.1.3 the applicant shall be
obliged by approval to inform the user in a proper way about the correct mounting position(s).
4.1.5. In addition to the mark prescribed in paragraph 3.1, an approval mark as described in paragraphs 4.2
and 4.3 below shall be affixed in the spaces referred to in paragraph 3.2 above to every installation unit of
a system conforming to a type approved under this Regulation.
4.1.6. The applicant shall indicate in a form corresponding to the respective model in the Annex 1 to this
Regulation, the vehicle(s) for which the system is intended.
4.1.7. If approval is sought for a system which is not intended to be included as part of the approval of a vehicle
type according to Regulation No 48,
4.1.7.1. The applicant shall submit sufficient documentation to prove the capability of the system to comply with the
provisions of paragraph 6.22 of Regulation No 48 when correctly installed, and
4.1.7.2. The system shall be approved according to Regulation No 10.
4.2. Composition of the approval mark
The approval mark shall consist of:
4.2.1. An international approval marking, comprising:
4.2.1.1. A circle surrounding the letter ‘E’ followed by the distinguishing number of the country which has granted
approval (5);
4.2.1.2. The approval number prescribed in paragraph 4.1.3 above;
(5) The distinguishing numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to the Consolid
ated Resolution on the Construction of Vehicles (R.E.3), document ECE/TRANS/WP.29/78/Rev.2/Amend.3 — www.unece.
org/trans/main/wp29/wp29wgs/wp29gen/wp29resolutions.htmlL 49/30 EN Official Journal of the European Union 20.2.2019
4.2.2. The following additional symbol (or symbols):
4.2.2.1. On a system, the letter ‘X’, and those of the function(s) being provided by the system:
‘C’ for the Class C passing-beam, with the addition of symbols for the relevant other classes of passing-
beam:
‘E’ for a Class E passing-beam,
‘V’ for a Class V passing-beam,
‘W’ for a Class W passing-beam;
‘R’ for a driving-beam;
4.2.2.2. In addition to each symbol and above it a score, if the lighting function or mode thereof is provided by more
than one installation unit from one side;
4.2.2.3. In addition the symbol ‘T’, after the symbol(s) of all lighting function(s) and/or class(es) designed to comply
with the respective bend lighting provisions, with said symbol(s) arranged together and leftmost;
4.2.2.4. On a separate installation unit, the letter ‘X’, and those of the function(s) being provided by the lighting
unit(s) comprised in it;
4.2.2.5. If the installation unit on a given side is not the only contributor to a lighting function or mode of a lighting
function it shall bear a score above the symbol of the function;
4.2.2.6. On a system or part thereof meeting left-hand traffic requirements only, a horizontal arrow pointing to the
right of an observer facing the installation unit, i.e. to the side of the road on which the traffic moves;
4.2.2.7. On a system or part thereof designed to meet the requirements of both traffic systems e.g. by means of an
appropriate adjustment of the setting of the optical element or the light source, a horizontal arrow with
a head on each end, the heads pointing respectively to the left and to the right;
4.2.2.8. On an installation unit incorporating a lens of plastic material, the group of letters ‘PL’ to be affixed near the
symbols prescribed in paragraphs 4.2.2.1 to 4.2.2.7 above;
4.2.2.9. On an installation unit contributing to fulfil the requirements of this Regulation in respect of the driving-
beam, an indication of the maximum luminous intensity expressed by the reference mark, as defined in
paragraph 6.3.2.1.2 below, placed near the circle surrounding the letter ‘E’;
4.2.3. In every case the relevant operating mode used during the test procedure according to paragraph 1.1.1.1 of
Annex 4 and the permitted voltage(s) according to paragraph 1.1.1.2 of Annex 4 shall be stipulated on the
approval forms and on the communication forms transmitted to the countries which are Contracting Parties
to the Agreement and which apply this Regulation.
In the corresponding cases, the system or part(s) thereof shall be marked as follows:
4.2.3.1. On an installation unit meeting the requirements of this Regulation which is so designed that the light
source(s) of the passing-beam shall not be lit simultaneously with that of any other lighting function with
which it may be reciprocally incorporated: an oblique stroke (/) shall be placed after the passing-beam
symbol(s) in the approval mark.
4.2.3.2. On an installation unit meeting the requirements of Annex 4 to this Regulation only when supplied with
a voltage of 6 V or 12 V, a symbol consisting of the number 24 crossed out by an oblique cross (X), shall be
placed near the holders of the light source(s).
4.2.4. The two digits of the approval number which indicate the series of amendments incorporating the most
recent major technical amendments made to the Regulation at the time of issue of the approval and, if
necessary, the required arrow may be marked close to the above additional symbols.
4.2.5. The marks and symbols referred to in paragraphs 4.2.1 and 4.2.2 above shall be clearly legible and be
indelible. They may be placed on an inner or outer part (transparent or not) of the installation unit which
cannot be separated from its light-emitting surface(s). In any case it shall be visible when the installation
unit(s) is/are fitted on the vehicle. The displacement of a movable part of the vehicle is permitted to fulfil this
requirement.20.2.2019 EN Official Journal of the European Union L 49/31
4.3. Arrangement of the approval mark
4.3.1. Independent lamps
Annex 2, Figures 1 to 10, to this Regulation gives examples of arrangements of the approval mark with the
above-mentioned additional symbols.
4.3.2. Grouped, combined or reciprocally incorporated lamps
4.3.2.1. Where lamps being grouped, combined or reciprocally incorporated with the system have been found to
comply with the requirements of several Regulations, a single international approval mark may be affixed,
consisting of a circle surrounding the letter ‘E’ followed by the distinguishing number of the country which
has granted the approval, and an approval number. This approval mark may be located anywhere on the
grouped, combined or reciprocally incorporated lamps, provided that:
4.3.2.1.1. It is visible as per paragraph 4.2.5;
4.3.2.1.2. No part of the grouped, combined or reciprocally incorporated lamps that transmit light can be removed
without at the same time removing the approval mark.
4.3.2.2. The identification symbol for each lamp appropriate to each Regulation under which approval has been
granted, together with the corresponding series of amendments incorporating the most recent major
technical amendments to the Regulation at the time of issue of the approval, and if necessary, the required
arrow shall be marked:
4.3.2.2.1. Either on the appropriate light-emitting surface,
4.3.2.2.2. Or in a group, in such a way that each of the grouped, combined or reciprocally incorporated lamps may be
clearly identified (see for possible examples in Annex 2).
4.3.2.3. The size of the components of a single approval mark shall not be less than the minimum size required for
the smallest of the individual marks by the Regulation under which approval has been granted.
4.3.2.4. An approval number shall be assigned to each type approved. The same Contracting Party may not assign the
same number to another type of grouped, combined or reciprocally incorporated lamps covered by this
Regulation.
4.3.2.5. Annex 2, Figures 11 and 12, to this Regulation give examples of arrangements of approval marks for
grouped, combined or reciprocally incorporated lamps with all the above mentioned additional symbols, and
relating to a system with functions provided by more than one installation unit per side of the vehicle.
4.3.2.6. Annex 2, Figure 13, to this Regulation gives examples of approval marks relating to the complete system.
B. TECHNICAL REQUIREMENTS FOR SYSTEMS OR PART(S) OF A SYSTEM
Unless otherwise specified, photometric measurements shall be carried out according to the provisions set
out in the Annex 9 to this Regulation.
5. GENERAL SPECIFICATIONS
The requirements contained in sections 5 ‘General specifications’ and 6 ‘Individual specifications’ and in the
Annexes referenced in the said sections of UN Regulation No 48, and their series of amendments in force at
the time of application for the lamp type approval shall apply to this Regulation.
The requirements pertinent to each lamp and to the category/ies of vehicle on which the lamp is intended to
be installed shall be applied, where its verification at the moment of lamp type approval is feasible.
5.1. Each sample, when its approval is sought for right-hand traffic only, shall conform to the specifications set
forth in paragraphs 6 and 7 below; if, however, its approval is sought for left-hand traffic, the provisions of
paragraph 6 below, including the relevant annexes to this Regulation, apply with the inversion of right to left
and vice versa.
Correspondingly, the designation of the angular positions and elements is adjusted by exchanging ‘R’ for ‘L’
and vice versa.
5.1.2. Systems or part(s) thereof, shall be so made as to retain their prescribed photometric characteristics and to
remain in good working order when in normal use, in spite of the vibrations to which they may be
subjected.L 49/32 EN Official Journal of the European Union 20.2.2019
5.2. Systems or part(s) thereof, shall be fitted with a device enabling them to be so adjusted on the vehicle as to
comply with the rules applicable to them.
5.2.1. Such adjustment device(s) need not be fitted on systems or part(s) thereof, provided that their use is confined
to vehicles on which the setting can be adjusted by other means or no such means are needed according to
the applicant's system description.
5.3. Replaceable and non-replaceable light sources and LED modules:
5.3.1. The system shall only be equipped with one or a combination of:
5.3.1.1. Light sources that are approved according to Regulation No 37 and its series of amendments in force at the
time of application for type approval and for which no restriction on the use is made;
5.3.1.2. Light sources that are approved according to Regulation No 99;
5.3.1.3. LED module(s).
5.3.2. If a light source is replaceable:
5.3.2.1. The lamp holder shall conform to the characteristics given on the data sheet of IEC Publication No 60061, as
referred to in the relevant light source Regulation.
5.3.2.2. The design of the device shall be such that the filament lamp can be fixed in no other position but the
correct one.
5.3.3. The Class C (basic) passing-beam shall be equipped only with replaceable light sources or replaceable or non-
replaceable LED modules.
5.3.4. In the case of replaceable LED module, the removal and replacement of this LED module, as described in
Annex 11, paragraph 1.4.1, shall be demonstrated to the satisfaction of the Technical Service.
5.4. System(s) or part(s) thereof, designed to satisfy the requirements both of right-hand and of left-hand traffic
may be adapted for traffic on a given side of the road either by an appropriate initial setting when fitted on
the vehicle or by selective setting by the user. In any case, only two different and clearly distinct settings, one
for right-hand and one for left-hand traffic, shall be possible, and the design shall preclude inadvertent
shifting from one setting to the other or setting in an intermediate state.
5.5. Complementary tests shall be done according to the requirements of Annex 4 to this Regulation to ensure
that in use there is no excessive change in photometric performance.
5.6. If the lens of a lighting unit is of plastic material, tests shall be done according to the requirements of
Annex 6 to this Regulation.
5.7. On a system or part(s) of, designed to provide alternately the driving-beam and the passing-beam, any
mechanical, electro-mechanical or other device incorporated in the lighting unit(s), for switching from one to
the other beam shall be so constructed that:
5.7.1. The device is robust enough to withstand 50 000 operations under normal conditions of use. In order to
verify compliance with this requirement, the Technical Service responsible for approval tests may:
(a) Require the applicant to supply the equipment necessary to perform the test;
(b) Forego the test if the headlamp presented by the applicant is accompanied by a test report, issued by
a Technical Service responsible for approval tests for headlamps of the same construction (assembly),
confirming compliance with this requirement.
5.7.2. Except in the case of adaptation of the driving-beam, either the passing-beam or the driving-beam shall
always be obtained, without any possibility of remaining in an intermediate or undefined state; if this is not
possible, such a state must be covered by the provisions according to paragraph 5.7.3 below;
5.7.3. In the case of failure it must be possible to obtain automatically a passing beam or a state with respect to the
photometric conditions which yields values not exceeding 1 300 cd in the zone III b as defined in Annex 3
to this Regulation and at least 3 400 cd in a point of ‘segment I ’, by such means as e.g. switching off,
max
dimming, aiming downwards, and/or functional substitution;
When performing the tests to verify compliance with these requirements, the Technical Service responsible
for approval tests shall refer to the instructions supplied by the applicant.20.2.2019 EN Official Journal of the European Union L 49/33
5.7.4. The user cannot, with ordinary tools, change the shape or position of the moving parts, or influence the
switching device.
5.8. Systems shall provide means allowing them to be used temporarily in a territory with the opposite direction
of driving than that for which approval is sought, without causing undue dazzle to the oncoming traffic. For
these purposes the system(s) or part(s) thereof shall:
5.8.1. Be capable of providing a selective setting by the user according to paragraph 5.4 above, without special
tools; or
5.8.2. Provide means to achieve a traffic-change function, meeting the values shown in the following table when
tested according to paragraph 6.2 below with the adjustment left unchanged compared to that for the
original traffic direction;
5.8.2.1. Passing-beam designed for right-hand traffic and adapted to left-hand traffic:
At 0,86 D —1,72 L at least 2 500 cd
At 0,57 U — 3,43 R not more than 880 cd
5.8.2.2. Passing-beam designed for left-hand traffic and adapted to right-hand traffic:
At 0,86 D — 1,72 R at least 2 500 cd
At 0,57 U — 3,43 L not more than 880 cd
5.9. The system shall be so made that, if a light source and/or a LED module has failed, a failure signal in order to
comply with the relevant provisions of Regulation No 48 shall be provided.
5.10. The component(s) to which a replaceable light source is assembled shall be so made that the light source fits
easily and, even in darkness, can be fitted in no position but the correct one.
5.11. In the case of a system according to paragraph 4.1.7 above.
5.11.1. The system shall be accompanied by a copy of the form according to paragraph 4.1.4 above and instructions
to enable its installation according to the provisions of Regulation No 48.
5.11.2. The Technical Service responsible for type approval shall verify that:
(a) The system can be correctly installed according to said instructions;
(b) The system, when installed in the vehicle, complies with the provisions of paragraph 6.22 of Regulation
No 48.
To confirm compliance with the provisions of paragraph 6.22.7.4 of Regulation No 48 a test drive is
mandatory, which comprises any situation relevant to the system control on the basis of the applicant's
description. It shall be notified whether all modes are activated, performing and de-activated according to the
applicant's description; obvious malfunctioning, if any, to be contested (e.g. angular excess or flicker).
5.12. The AFS, if equipped with LED module(s), and the LED module(s) themselves shall comply with the relevant
requirements specified in Annex 11 to this Regulation. The compliance with the requirements shall be tested.
5.13. In case of an AFS incorporating light sources and/or LED module(s) producing the basic passing-beam and
having a total objective luminous flux of the lighting units as indicated under item 9.2.3 of the communi
cation form conforming to the model in Annex 1 which exceeds 2 000 lumens per side a reference shall be
made in item 9.2.3 of the communication form in Annex 1. The objective luminous flux of LED module(s)
shall be measured as described in paragraph 5 of Annex 11.
5.14. In the case of the basic passing-beam in the neutral state being produced exclusively by LED modules, the
total objective luminous flux of these LED modules shall be equal or greater than 1 000 lumen per side,
when measured as described in paragraph 5 of Annex 11.
5.15. A LED module shall be:
(a) Only removable from its device with the use of tools, unless it is stated in the communication sheet that
the LED module is non-replaceable and,
(b) So designed that regardless of the use of tool(s), it is not mechanically interchangeable with any
replaceable approved light source.L 49/34 EN Official Journal of the European Union 20.2.2019
6. ILLUMINATION
6.1. General provisions
6.1.1. Each system shall provide a Class C passing-beam according to paragraph 6.2.4 below and one or more
passing-beam(s) of additional class(es); it may incorporate one or more additional modes within each class of
passing-beam and the front-lighting functions according to paragraph 6.3 and/or 2.1.1.1 of this Regulation.
6.1.2. The system shall provide automatic modifications, such, that good road illumination is achieved and no
discomfort is caused, neither to the driver nor to other road users.
6.1.3. The system shall be considered acceptable if it meets the relevant photometric requirements of paragraphs 6.2
and 6.3.
6.1.4. Photometric measurements shall be performed according to the applicant's description:
6.1.4.1. At neutral state according to paragraph 1.9 of this Regulation;
6.1.4.2. At V-signal, W-signal, E-signal, T-signal according to paragraph 1.10 of this Regulation, whichever apply;
6.1.4.3. If applicable, at any other signal(s) according to paragraph 1.10 of this Regulation and combinations of them,
according to the applicant's specification.
6.1.4.4. In case of a headlamp using a gas-discharge light source with the ballast not integrated with the light source,
four seconds after ignition of a headlamp that has not been operated for 30 minutes or more:
6.1.4.4.1. At least 37 500 cd shall be attained at point HV, for a system producing driving-beam only.
6.1.4.4.2. At least 3 100 cd shall be attained at point 50 V when the Class C passing-beam is activated, for systems
producing passing-beam only or alternately producing passing-beam and driving-beam functions as described
in paragraph 5.7 of this Regulation.
6.1.4.4.3. In either case the power supply shall be sufficient to secure the required rise of the high current pulse.
6.2. Provisions concerning the passing-beam
The system shall, prior to the subsequent test procedures, be set to the neutral state, emitting the Class C
passing-beam.
6.2.1. For each side of the system (vehicle) the passing-beam in its neutral state shall produce from at least one
lighting unit a ‘cut-off’ as defined in Annex 8 to this Regulation or,
6.2.1.1. The system shall provide other means, e.g. optical features or temporary auxiliary beams, allowing for
unambiguous and correct aiming.
6.2.1.2. Annex 8 does not apply to the traffic-change function as described in paragraph 5.8 through 5.8.2.1 above.
6.2.2. The system or part(s) thereof shall be aimed according to the requirements of Annex 8 so that the position
of the cut–off complies with the requirements indicated in the Table 2 of Annex 3 to this Regulation.
6.2.3. When so aimed, the system or part(s) thereof, if its approval is sought solely for provision of the passing-
beam, needs to comply with the requirements set out in the relevant paragraphs below; if it is intended to
provide additional lighting or light signalling functions according to the scope of this Regulation, it shall
comply in addition with the requirements set out in the relevant paragraphs below, if not being adjustable in
dependently.
6.2.4. When emitting a specified mode of the passing beam, the system shall meet the requirements in the
respective section (C, V, E, W) of part A of Table 1 (photometric values) and in Table 2 (I and ‘cut-off’
max
positions) of Annex 3 to this Regulation, as well as section 1 (‘cut-off’ requirements) of Annex 8 to this
Regulation.
6.2.5. A bending mode may be emitted, provided that:
6.2.5.1. The system meets the respective requirements of part B of Table 1 (photometric values) and item 2.2 of
Table 2 (‘cut-off’ provisions) of Annex 3 to this Regulation, when measured according to the procedure
indicated in Annex 9, relevant to the category (either category 1 or category 2) of the bending mode, for
which approval is sought;20.2.2019 EN Official Journal of the European Union L 49/35
6.2.5.2. When the T-signal corresponds to the vehicle's smallest turn radius to the left (or right), the sum of the
luminous intensity values provided by all contributors of the right or the left side of the system shall be at
least 2 500 cd at one or more points in the zone extending from H-H to 2 degrees below H-H and from 10
to 45 degrees left (or right).
6.2.5.3. If approval is sought for a category 1 bending mode, the use of the system is restricted to vehicles where
provisions are taken such that the horizontal position of the ‘kink’ of the ‘cut-off’ which is provided by the
system, complies with the relevant provisions of paragraph 6.22.7.4.5(i) of Regulation No 48;
6.2.5.4. If approval is sought for a category 1 bending mode, the system is designed so that, in the case of a failure
affecting the lateral movement or modification of the illumination, it must be possible to obtain automatically
either photometric conditions corresponding to paragraph 6.2.4 above or a state with respect to the
photometric conditions which yields values not exceeding 1 300 cd in the zone IIIb, as defined in Annex 3
to this Regulation, and at least 3 400 cd in a point of ‘segment I ’;
max
6.2.5.4.1. However, this is not needed if, for positions relative to the system reference axis up to 5 degrees left, at
0,3 degree up from H-H, and greater than 5 degrees left, at 0,57 degree up, a value of 880 cd is in no case
exceeded.
6.2.6. The system shall be checked on the basis of the relevant instructions of the manufacturer, indicated in the
safety concept according to paragraph 2.2.2.1 above.
6.2.7. A system or part(s) thereof, designed to meet the requirements of both right-hand and left-hand traffic must,
in each of the two setting positions according to 5.4 above meet the requirements specified for the
corresponding direction of traffic.
6.2.8. The system shall be so made that:
6.2.8.1. Any specified passing-beam mode provides at least 2 500 cd at point 50 V from each side of the system;
The mode(s) of the Class V passing-beam are exempted from this requirement;
6.2.8.2. Other modes:
When signal inputs according to paragraph 6.1.4.3 of this Regulation apply, the requirements of the
paragraph 6.2 above shall be fulfilled.
6.3. Provisions concerning the driving-beam
The system shall, prior to the subsequent test procedures, be set to the neutral state.
6.3.1. The lighting unit(s) of the system shall be adjusted, according to the instructions of the manufacturer, such
that the area of maximum illumination is centred on the point (HV) of intersection of the lines H-H and V-V;
6.3.1.1. Any lighting unit(s) which is/are not independently adjustable, or, for which the aiming was done with
respect to any measurements under paragraphs 6.2., shall be tested in its/their unchanged position.
6.3.2. When measured according to the provisions laid down in Annex 9 to this Regulation the illumination shall
meet the following requirements:
Angular coordinates Required luminous intensity
Test point
(degrees) (cd)
Min
Im 40 500
H-5L 0,0, 5,0 L 5 100
H-2,5L 0,0, 2,5 L 20 300
H-2,5R 0,0, 2,5 R 20 300
H-5R 0,0, 5,0 R 5 100
6.3.2.1. The point of intersection (HV) of lines h-h and v-v shall be situated within the isolux 80 per cent of
maximum luminous intensity (I )
max
6.3.2.1.1. The maximum value (I ) shall in no circumstances exceed 215 000 cd.
ML 49/36 EN Official Journal of the European Union 20.2.2019
6.3.2.1.2. The reference mark (I′ ) of this maximum intensity, referred to in paragraph 4.2.2.9 above, shall be obtained
M
by the ratio:
I′ = I /4 300
M M
This value shall be rounded off to the value of: 5 – 10 – 12,5 – 17,5 – 20 – 25 – 27,5 – 30 – 37,5 – 40 –
45 – 50.
6.3.3. The illumination or part thereof emitted by the system may be automatically laterally moved (or modified to
obtain an equivalent effect), provided that:
6.3.3.1. The system meets the requirements of the paragraphs 6.3.2.1.1 and 6.3.2.1.2 above with each lighting unit
measured according to the relevant procedure indicated in Annex 9.
6.3.4. The system shall be so made that:
6.3.4.1. The lighting unit(s) of the right side and of the left side each provide at least 16 200 cd at the point HV.
6.3.5. If the specified beam requirements are not met, a re-aiming of the beam position within 0,5 degree up or
down and/or 1 degree to the right or left, with respect to its initial aiming is allowed; in the revised position
all photometric requirements shall be met. These provisions do not apply to lighting units as indicated under
paragraph 6.3.1.1 of this Regulation.
6.3.6. In the case of adaptation of the driving-beam function the system shall meet the requirements of the above
paragraphs only when it is in the maximum condition of activation.
6.3.7. During adaptation, the driving-beam function shall meet the requirements for all the cases of right-hand and
left-hand traffic specified in Part A of Table 7 in Annex 3 to this Regulation. These requirements shall be
verified during the type approval testing in conjunction with a signal generator to be provided by the
applicant. This signal generator shall reproduce the signals provided by the vehicle and cause the adaptation
of the driving-beam and in particular shall represent the settings so that the photometric compliance can be
verified.
6.3.7.1. If the driving-beam function meets the requirements in Part A of Table 7 in Annex 3 to this Regulation
specified for line 1 to line 3 for oncoming and preceding vehicles (symmetrical beam) the relevant
information shall be noticed in the communication document in Annex 1, item 18.5.
6.3.7.2. If the requirements of paragraph 6.3.7 above can be met for right-hand traffic or left-hand traffic only, the
relevant information shall be reported in the communication document in Annex 1, item 18.5.
6.4. Other provisions
In the case of a system or part(s) thereof with adjustable lighting units the requirements of paragraphs 6.2
(passing-beam) and 6.3 (driving-beam) are applicable for each mounting position indicated according to
paragraph 2.1.3 of this Regulation (adjustment range). For verification the following procedure shall be used:
6.4.1. Each applied position is realized on the test goniometer with respect to a line joining the centre of reference
and point HV on an aiming screen. The adjustable system or part(s) thereof is then moved into such
a position that the light pattern on the screen corresponds to the relevant aiming prescriptions;
6.4.2. With the system or part(s) thereof initially fixed according to paragraph 6.4.1 above, the device or part(s)
thereof must meet the relevant photometric requirements of paragraphs 6.2 and 6.3 above;
6.4.3. Additional tests shall be made after the reflector/system or part(s) thereof has been moved vertically ± 2
degrees or at least into the maximum position if less than 2 degrees, from its initial position by means of the
system or part(s) thereof adjusting device. Having re-aimed the system or part(s) thereof as a whole (by
means of the goniometer for example) in the corresponding opposite direction the light output in the
following directions shall be controlled and lie within the required limits:
6.4.3.1. Passing beam: points B50L and 75R, or 50R if applicable;
Driving beam: I and point HV (percentage of I );
M M
6.4.4. If the applicant has indicated more than one mounting position, the procedure of paragraphs 6.4.1 to 6.4.3
above shall be repeated for all other positions;20.2.2019 EN Official Journal of the European Union L 49/37
6.4.5. If the applicant has not asked for special mounting positions, the system or part(s) thereof shall be aimed for
measurements of paragraphs 6.2 (passing-beam) and 6.3 above (driving-beam) with the relevant adjusting
device(s) of the system or part(s) thereof in its mean position. The additional test of paragraph 6.4.3 above
shall be made with the system or part(s) thereof, moved into its extreme positions (instead of ± 2 degrees) by
means of the relevant adjusting device(s).
6.4.6. It shall be stated by means of a form conforming to the model in Annex 1 to this Regulation, which lighting
unit(s) provide a ‘cut-off’ as defined in Annex 8 to this Regulation, that projects into a zone extending from
6 degrees left to 4 degrees right and upwards from a horizontal line positioned at 0,8 degree down.
6.4.7. It shall be stated by means of a form conforming to the model in Annex 1 to this Regulation, which Class E
passing-beam mode(s), if any, comply with a ‘data set’ of Table 6 of Annex 3 to this Regulation.
7. COLOUR
7.1. The colour of the light emitted shall be white.
C. FURTHER ADMINISTRATIVE PROVISIONS
8. MODIFICATION OF THE SYSTEM TYPE AND EXTENSION OF APPROVAL
8.1. Every modification of the system type shall be notified to the Type Approval Authority which approved the
system type. The said Authority may then either:
8.1.1. Consider that the modifications made are unlikely to have appreciable adverse effects and that in any event
the system still complies with the requirements; or
8.1.2. Require a further test report from the Technical Service responsible for conducting the tests.
8.2. Confirmation or refusal of approval, specifying the alterations, shall be communicated by the procedure
specified in paragraph 4.1.4 above to the Contracting Parties to the Agreement which apply this Regulation.
8.3. The Type Approval Authority issuing the extension of approval shall assign a series number to each
communication form drawn up for such an extension and inform thereof the other Parties to the
1958 Agreement applying this Regulation by means of a communication form conforming to the model in
Annex 1 to this Regulation.
9. CONFORMITY OF PRODUCTION
The conformity of production procedures shall comply with those set out in the Agreement, Appendix 2
(E/ECE/324-E/ECE/TRANS/505/Rev.2) with the following requirements:
9.1. A system approved under this Regulation shall be so manufactured as to conform to the type approved by
meeting the requirements set forth in paragraphs 6 and 7 above.
9.2. The minimum requirements for conformity of production control procedures set forth in Annex 5 to this
Regulation shall be complied with.
9.3. The minimum requirements for sampling by an inspector set forth in Annex 7 to this Regulation shall be
complied with.
9.4. The Type Approval Authority which has granted type approval may at any time verify the conformity control
methods applied in each production facility. The normal frequency of these verifications shall be once every
two years.
9.5. Systems or part(s) thereof with apparent defects are disregarded.
9.6. The reference mark is disregarded.
10. PENALTIES FOR NON-CONFORMITY OF PRODUCTION
10.1. The approval granted in respect of a type of system pursuant to this Regulation may be withdrawn if the
requirements are not complied with or if a system or part(s) thereof bearing the approval mark does not
conform to the type approved.
10.2. If a Contracting Party to the Agreement applying this Regulation withdraws an approval it has previously
granted, it shall forthwith so notify the other Contracting Parties applying this Regulation by means of
a communication form conforming to the model in Annex 1 to this Regulation.L 49/38 EN Official Journal of the European Union 20.2.2019
11. PRODUCTION DEFINITIVELY DISCONTINUED
11.1. If the holder of the approval completely ceases to manufacture a type of system approved in accordance with
this Regulation, he shall so inform the Type Approval Authority, which granted the approval. Upon receiving
the relevant communication, that Authority shall inform thereof the other Contracting Parties to the 1958
greement applying this Regulation by means of a communication form conforming to the model in Annex 1
to this Regulation.
12. NAMES AND ADDRESSES OF TECHNICAL SERVICES RESPONSIBLE FOR CONDUCTING APPROVAL TESTS AND OF
TYPE APPROVAL AUTHORITIES
12.1. The Contracting Parties to the 1958 Agreement applying this Regulation shall communicate to the United
Nations Secretariat the names and addresses of the Technical Services responsible for conducting approval
tests and of the Type Approval Authorities which grant approval and to which forms certifying approval or
extension or refusal or withdrawal of approval, or production definitively discontinued, issued in other
countries, are to be sent.
13. TRANSITIONAL PROVISIONS
13.1. From the date of entry into force of the 01 series of amendments to this Regulation, no Contracting Party
applying it shall refuse to grant approvals under this Regulation as amended by the 01 series of amendments.
13.2. Until 60 months after the date of entry into force of the 01 series of amendments to this Regulation with
regard to the changes introduced by the 01 series of amendments concerning the photometric testing
procedures involving the use of the spherical coordinate system and the specification of luminous intensity
values, and in order to allow the Technical Services to update their testing equipment, no Contracting Party
applying this Regulation shall refuse to grant approvals under this Regulation as amended by the 01 series of
amendments where existing testing equipment is used with suitable conversion of the values, to the
satisfaction of the authority responsible for type approval.
13.3. As from 60 months after the date of entry into force of the 01 series of amendments, Contracting Parties
applying this Regulation shall grant approvals only if the system meets the requirements of this Regulation as
amended by the 01 series of amendments.
13.4. Existing approvals for systems already granted under this Regulation before the date of entry into force of the
01 series of amendments shall remain valid indefinitely.
13.5. Contracting Parties applying this Regulation shall not refuse to grant extensions of approvals to the preceding
series to this Regulation.20.2.2019 EN Official Journal of the European Union L 49/39
ANNEX 1L 49/40 EN Official Journal of the European Union 20.2.201920.2.2019 EN Official Journal of the European Union L 49/41L 49/42 EN Official Journal of the European Union 20.2.2019
ANNEX 2
EXAMPLES OF ARRANGEMENTS OF APPROVAL MARKS
Example 1
a ≥ 8 mm (on glass)
a ≥ 5 mm (on plastic material)
Figure 1 Figure 2
The installation unit of a system, bearing one of the above approval marks has been approved in the Netherlands (E 4)
pursuant to this Regulation under approval number 19243, meeting the requirements of this Regulation in its original
form (00). The passing-beam is designed for right-hand traffic only. The letters ‘CT’ (Figure 1) indicate that it concerns
a passing-beam with bending mode and the letters ‘CWR’ (Figure 2) indicate that it concerns a Class C passing-beam and
a Class W passing-beam and a driving-beam.
Number 30 indicates that the maximum luminous intensity of the driving-beam is between 123 625 and
145 125 candelas.
Note: The approval number and additional symbols shall be placed close to the circle surrounding the letter ‘E’ and either
above or below that letter ‘E’, or to the right or left of that letter. The digits of the approval number shall be on the
same side of that letter ‘E’ and face in the same direction.
The use of Roman numerals as approval numbers should be avoided so as to prevent any confusion with other symbols.
Example 2
Figure 3 Figure 4a20.2.2019 EN Official Journal of the European Union L 49/43
Figure 4b
The installation unit of a system, bearing the above approval mark, meets the requirements of this Regulation in respect
of both the passing-beam and the driving-beam and is designed:
Figure 3: Class C passing-beam with Class E passing-beam for left-hand traffic only.
Figures 4a and 4b: Class C passing-beam with Class V passing-beam for both traffic systems by means of an appropriate
adjustment of the setting of the optical element or the light source on the vehicle, and a driving-beam. Class C passing-
beam, Class V passing-beam and driving-beam comply to bending lighting provisions, as indicated by the letter ‘T’. The
score above the letter ‘R’ indicates that the driving-beam function is provided by more than one installation unit on that
side of the system.
Example 3
Figure 5 Figure 6
The installation unit, bearing the above approval mark is incorporating a lens of plastic material and meeting the
requirements of this Regulation in respect of the passing-beam only and is designed:
Figure 5: Class C passing-beam and Class W passing-beam for both traffic systems.
Figure 6: Class C passing-beam with bending mode for right-hand traffic only.
Example 4
Figure 7 Figure 8
Figure 7: The installation unit, bearing this approval mark is meeting the requirements of this Regulation in respect of
the Class C passing-beam with Class V passing-beam and designed for left-hand traffic only.
Figure 8: The installation unit, bearing this approval mark is a (separate) installation unit of a system, meeting the
requirements of this Regulation in respect of the driving-beam only.L 49/44 EN Official Journal of the European Union 20.2.2019
Example 5
Identification of an installation unit incorporating a lens of plastic material meeting the requirements of this Regulation.
Figure 9 Figure 10
Figure 9: In respect to the Class C passing-beam, the Class W passing-beam both with bending modes and a driving-
beam, and designed for right-hand traffic only.
The passing-beam and its modes shall not be operated simultaneously with the driving-beam in and/or another
reciprocally incorporated headlamp.
Figure 10: In respect to the Class E passing-beam, the Class W passing-beam, designed for right-hand traffic only and
a driving-beam. The score above the letters ‘E’ and ‘W’ indicates that these passing-beam classes are provided on that
side of the system by more than this installation unit.
Example 6
Simplified marking for grouped, combined or reciprocally incorporated lamps, when approved according to other than
this Regulation (Figure 11). (The vertical and horizontal lines schematise the shape of the light-signalling device. They
are not part of the approval mark.)
These two examples correspond to two installation units on one side of a system, bearing an approval mark comprising
(Model A and B):
Installation unit 1
A front position lamp approved in accordance with the 02 series of amendments of Regulation No 7;
One or more lighting unit(s), with a Class C passing-beam with bending mode provided to work with one or more other
installation unit(s) on the same side of the system (as indicated by the score above the letter ‘C’) and a Class V passing-
beam, both designed for right- and left-hand traffic and a driving-beam with a maximum intensity comprised between
123 625 and 145 125 candelas approved in accordance with the requirements of this Regulation in its original form
(00) and incorporating a lens of plastic material;
A daytime running light approved in accordance with the original version of Regulation No 87;
A front direction indicator lamp of category 1a approved in accordance with the 01 series of amendments to Regulation
No 6.
Installation unit 3
A front fog lamp approved in accordance with the 02 series of amendments to Regulation No 19, or a Class C passing-
beam with bending mode, designed for right- and left-hand traffic, provided to work with one or more other installation
unit(s) on that side of the system, as indicated by the score above the letter ‘C’.20.2.2019 EN Official Journal of the European Union L 49/45
Figure 11
Installation unit 1 of the system
Installation unit 3 of the system
Example 7
Arrangement of approval marks relative to a system (Figure 12)
Figure 12L 49/46 EN Official Journal of the European Union 20.2.2019
These two examples correspond to an adaptive front-lighting system composed of two installation units (providing the
same functions) per side of the system (units 1 and 3 for the left side, and units 2 and 4 for the right side).
The installation unit 1 (or 2) of the system bearing the above approval marks meeting the requirements of this
Regulation (00 series of amendments) in respect of both a Class C passing-beam for left-hand traffic and a driving-beam
with a maximum luminous intensity comprised between 123 625 and 145 125 candelas (indicated by the number 30),
grouped with a front direction indicator lamp of category 1a, approved in accordance with the 01 series of amendments
of Regulation No 6.
In example 7a: the installation unit 1 (or 2) of the system comprises a Class C passing-beam with bending mode,
a Class W passing-beam, a Class V passing-beam and a Class E passing-beam. The score above the letter ‘C’ indicates that
the Class C passing-beam is provided by two installation units on that side of the system.
The installation unit 3 (or 4) is designed to provide a second part of the Class C passing-beam on that side of the system
as indicated by the score above ‘C’.
In example 7b: the installation unit 1 (or 2) of the system is designed to provide a Class C passing-beam, a Class W
passing-beam and a Class E passing-beam. The score above the letter ‘W’ indicates that the Class W passing-beam is
provided by two installation units on that side of the system. The letter ‘T’ to the right, following the listed symbols (and
left of the approval number) indicates that each, the Class C passing-beam, the Class W passing-beam, the Class E
passing-beam, and the driving-beam are providing a bending mode.
The installation unit 3 (or 4) of the system is designed to provide the second part of the Class W passing-beam on that
side of the system (as indicated by the score above the letter ‘W’), and the Class V passing-beam.
Example 8
Arrangement of approval marks relative to both sides of a system (Figure 13)
This example corresponds to an adaptive front-lighting system composed of two installation units for the left side of the
vehicle and one installation unit for the right side.
Figure 13
Right side of the system/vehicle Left side of the system/vehicle
The system bearing the above approval marks meets the requirements of this Regulation (original version of the
Regulation) in respect of both a passing-beam for left-hand traffic and a driving-beam with a maximum intensity
comprised between 86 250 and 101 250 candelas (as indicated by the number 30) grouped with a front direction
indicator lamp of category 1a, approved in accordance with the 01 series of amendments of Regulation No 6 and
a front position lamp approved in accordance with the 02 series of amendments of Regulation No 7.
The installation unit 1 of the system (left side) is designed to contribute to the Class C passing-beam and the Class E
passing-beam. The score above the letter ‘C’ indicates that on that side more than one installation unit contributes to the
Class C passing-beam. The letter ‘T’ to the right following the listed symbols indicates that each, the Class C passing-
beam and the Class E passing-beam are providing a bending mode.20.2.2019 EN Official Journal of the European Union L 49/47
The installation unit 3 of the system (left side) is designed to provide the second part of the Class C passing-beam of
that side (as indicated by the score above the letter ‘C’) and a Class W passing-beam.
The installation unit 2 of the system (right side) is designed to contribute to the Class C passing-beam, a Class E passing-
beam, both with bending mode and a Class W passing-beam.
Note: In the above examples Nos 6 and 7, the different installation units of the system shall bear the same approval
number.
Figure 14
LED modules
MD E3 17325
The LED module bearing the light source module identification code shown above has been approved together with an
AFS initially approved in Italy (E 3) under approval number 17325.L 49/48 EN Official Journal of the European Union 20.2.2019
ANNEX 3
PASSING-BEAM PHOTOMETRIC REQUIREMENTS (*)
For the purpose of this annex:
‘above it’ means vertically above, only;
‘below it’ means vertically below, only.
Angular positions are expressed in deg up (U) or down (D) from H-H respectively right (R) or left (L) from V-V.
Figure 1
Angular positions of passing beam photometric requirements (indicated for right-hand traffic)
(*) Note: Measurement procedure prescribed in Annex 9 to this Regulation.Table 1
Passing-beam photometric requirements
Position/deg Passing-beam
Tabled requirements expressed in cd
horizontal vertical Class C Class V Class E Class W
No Element at/ from to at min max min max min max min max
A
traP
1 B50L L 3,43 U 0,57 50(4) 350 50 350 50 625(7) 50 625
2 HV V H 50(4) 625 50 625 50 50
3 BR R 2,5 U 1 50(4) 1 750 50 880 50 1 750 50 2 650
4 Segment BRR R 8 R 20 U 0,57 50(4) 3 550 880 3 550 5 300
5 Segment BLL L 8 L 20 U 0,57 50(4) 625 880 880 880
6 P L 7 H 63 63
7 Zone III (as specified by Table 3 of 625 625 880 880
this annex)
8a S50 + S50LL + S50RR(5) U 4 190(6) 190(6) 190(6)
9a S100 + S100LL + S100RR(5) U 2 375(6) 375(6) 375(6)
10 50 R R 1,72 D 0,86 5 100
11 75 R R 1,15 D 0,57 10 100 15 200 20 300
12 50 V V D 0,86 5 100 5 100 10 100 10 100
13 50 L L 3,43 D 0,86 3 550 13 200(8) 3 550 13 200(8) 6 800 6 800 26 400(8)
14 25 LL L 16 D 1,72 1 180 845 1 180 3 400
15 25 RR R 11 D 1,72 1 180 845 1 180 3 400
16 Segment 20 and below it L 3,5 V D 2 17 600(2)
17 Segment 10 and below it L 4,5 R 2,0 D 4 12 300(1) 12 300(1) 12 300(1) 7 100(2)
18 I (3) 16 900 44 100 8 400 44 100 16 900 79 300(7) 29 530 70 500(2)
max
20.2.2019
EN
Official
Journal
of
the
European
Union
L
49/49Position/deg Passing-beam
Tabled requirements expressed in cd
horizontal vertical Class C Class V Class E Class W
No Element at/ from to at min max min max min max min max
Part B (bending modes): Table 1 Part A applies, however with the lines Nos 1, 2, 7, 13 and 18 being replaced by those listed hereunder
B
traP
1 B50L L 3,43 U 0,57 50(4) 530 530 790
2 HV(4) 50(4) 880 880
7 Zone III (as specified by Table 3 of 880 880 880 880
this annex)
13 50L L 3,43 D 0,86 1 700 1 700 3 400 3 400
18 I 10 100 44 100 5 100 44 100 10 100 79 300(7) 20 300 70 500(2)
max
(1) Max 15 900 cd, if the system is designed to provide also a Class W passing-beam.
(2) Requirements according to the provisions indicated in Table 4 below apply in addition
(3) Requirements according to the provisions of Table 2 below (‘Segment I ’) apply in addition
max
(4) The contribution of each side of the system (for segment BLL and BRR: of at least one point), when measured according to the provisions of Annex 9 to this Regulation shall not be less than 50 cd.
(5) Position requirements according to the provisions of Table 5 below.
(6) One pair of position lamps, being incorporated with the system or being intended to be installed together with the system may be activated according to the indications of the applicant.
(7) Requirements according to the provisions indicated in Table 6 below apply in addition.
(8) The max. value may be multiplied by 1,4, if it is guaranteed according to the manufacturer's description that this value will not be exceeded in use, either by means of the system or, if the system's use is con
fined to vehicles, providing a corresponding stabilization/limitation of the system's supply, as indicated in the communication form.
L
49/50
EN
Official
Journal
of
the
European
Union
20.2.201920.2.2019 EN Official Journal of the European Union L 49/51
Table 2
Passing beam elements angular position/extend, additional requirements
Class C passing-beam Class V passing-beam Class E passing-beam Class W passing-beam
Beam part designation and require
No horizontal vertical horizontal vertical horizontal vertical horizontal vertical
ment
2.1. Angular position/extend in deg 0,5 L to 0,3 D to 0,3 D to 0,5 L to 0,1 D to 0,5 L to 0,3 D to
for segment I 3 R 1,72 D 1,72 D 3 R 1,72 D 3 R 1,72 D
max
The maximum luminous inten
sity in ‘Segment I ’ as indi
max
cated in this table shall be
within the limits as prescribed
in Table 1, Line No 18.
2.2. The ‘cut-off’ and part(s) of shall:
(a) comply with the requirements of paragraph 1 of Annex 8 to this Regulation and
(b) be positioned with its ‘flat at V = not above not above not above
horizontal part’ 0,57 D 0,57 D 0,23 D(1) 0,23 D
not below not below not below
1,3 D 0,57 D 0,57 D
(1) Requirements according to the provisions indicated in Table 6 below apply in addition.
Table 3
Passing-beam zones III, defining corner points
Angular Position in Deg Corner Point No 1 2 3 4 5 6 7 8
Zone III a horizontal 8 L 8 L 8 R 8 R 6 R 1,5 R V-V 4 L
for Class C or Class V Passing
Beam vertical 1 U 4 U 4 U 2 U 1,5 U 1,5 U H-H H-H
Zone III b horizontal 8 L 8 L 8 R 8 R 6 R 1,5 R 0,5 L 4 L
for Class W or Class E Passing
Beam vertical 1 U 4 U 4 U 2 U 1,5 U 1,5 U 0,34 U 0,34 U
Table 4
Additional provisions for Class W passing-beam, expressed in cd
4.1. Definition and requirements for segments E, F1, F2, and F3 (not shown in Fig. 1 above).
Not more than 175 cd is allowed: (a) on a segment E extending at U 10 deg from L 20 to R 20 deg and (b) on three vertical
segments F1, F2 and F3 at horizontal positions L10 degrees, V and R 10 degrees, each extending from U 10 to U 60 de
grees.
4.2. Alternative/Additional set of requirements for I , segment 20 and segment 10:
max
Table 1 Part A or B applies, however with the max requirements in lines No 16, 17 and 18 being replaced by those indicated
hereunder.
If, according to the applicants specification according to paragraph 2.2.2(e) of this Regulation a Class W passing-beam is de
signed to produce on segment 20 and below it not more than 8 800 cd and on segment 10 and below it not more than
3 550 cd, the design value for I of that beam shall not exceed 88 100 cd.
maxL 49/52 EN Official Journal of the European Union 20.2.2019
Table 5
Overhead sign requirements, angular position of measurement points
Point designation S50LL S50 S50RR S100LL S100 S100RR
Angular position in degrees 4 U/8 L 4 U/V-V 4 U/8 R 2 U/4 L 2 U/V-V 2 U/4 R
Table 6
Additional provisions for Class E passing-beam
Table 1 Part A or B and Table 2 above apply, however with the lines No 1 and 18 of Table 1 and item 2.2 of Table 2 being replaced
as indicated hereunder.
Item Designation Line 1 of Table 1 above, Line 18 of Table 1 above, Item 2.2 of Table 2 above
Part A or B Part A or B
No Data Set EB50L in cd I in cd cut-off flat part aimed in
max
degrees
max max not above
6.1. E1 530 70 500 0,34 D
6.2. E2 440 61 700 0,45 D
6.3. E3 350 52 900 0,57 D
Table 7
Requirements concerning the adaptation of the driving-beam according to paragraph 6.3.7 of this
Regulation
Position/Deg. Max. intensity(**)
Part A
Test point
Horizontal Vertical (cd)
Line 1 Left
Oncoming vehicle at 50 m in the case of 4,8° L to 2° L 0,57° Up 625
right-hand traffic
Line 1 Right
Oncoming vehicle at 50 m in the case of 2° R to 4,8° R 0,57° Up 625
left-hand traffic
Line 2 Left
Oncoming vehicle at 100 m in the case of 2,4° L to 1° L 0,3° Up 1 750
right-hand traffic
Line 2 Right
Oncoming vehicle at 100 m in the case of 1° R to 2,4° R 0,3° Up 1 750
left-hand traffic
Line 3 Left
Oncoming vehicle at 200 m in the case of 1,2° L to 0,5° L 0,15° Up 5 450
right-hand traffic
Line 3 Right
Oncoming vehicle at 200 m in the case of 0,5° R to 1,2° R 0,15° Up 5 450
left-hand traffic20.2.2019 EN Official Journal of the European Union L 49/53
Position/Deg. Max. intensity(**)
Part A
Test point
Horizontal Vertical (cd)
Line 4 1,7° L to1,0° R 1 850
Preceding vehicle at 50 m in the case of
right-hand traffic > 1,0° R to 1,7° R 2 500
0,3° Up
Line 4 1,7° R to1,0° L 1 850
Preceding vehicle at 50 m in the case of
left-hand traffic > 1,0° L to 1,7° L 2 500
Line 5 0,9° L to 0,5° R 5 300
Preceding vehicle at 100 m in the case of
right-hand traffic > 0,5° R to 0,9° R 7 000
0,15° Up
Line 5 0,9° R to 0,5° L 5 300
Preceding vehicle at 100 m in the case of
left-hand traffic > 0,5° L to 0,9° L 7 000
Line 6
Preceding vehicle at 200 m in the case of 0,45° L to 0,45° R 0,1° Up 16 000
left-hand traffic and right-hand traffic
Part B Position/degrees(*) Min, Intensity(**)
Test Point
Horizontal Vertical (cd)
50R 1,72 R D 0,86 5 100
50V V D 0,86 5 100
50L 3,43 L D 0,86 2 550
25LL 16 L D 1,72 1 180
25RR 11 R D 1,72 1 180
(*) Angular positions are indicated for right-hand traffic.
(**) The photometric requirements for each single measuring point (angular position) of this lighting function apply to half of the sum
of the respective measured values from all lighting units of the system applied for this function.
Each of the lines defined in part A of Table 7, in conjunction with the test points as prescribed in part B of Table 7 shall be mea
sured individually corresponding to the signal provided by the signal generator.
In the case where the passing-beam, which meets the requirements of paragraph 6.2 of this Regulation, is continuously operated in
conjunction with the adaptation of the driving-beam, the photometric requirements in Part B of the Table 7 shall not be applied.L 49/54 EN Official Journal of the European Union 20.2.2019
ANNEX 4
TESTS FOR STABILITY OF PHOTOMETRIC PERFORMANCE OF SYSTEMS IN OPERATION — TESTS ON
COMPLETE SYSTEMS
Tests on complete systems
Once the photometric values have been measured according to the prescriptions of this Regulation, in the
point of I for driving beam and in points 25L, 50V and B50L (or R), whichever applies for passing beam,
max
a complete system sample shall be tested for stability of photometric performance in operation.
For the purpose of this annex:
(a) ‘Complete system’ shall be understood to mean the complete right and left side of a system itself including
electronic light source control-gear(s) and/or supply and operating device(s) and those surrounding body
parts and lamps which could influence its thermal dissipation. Each installation unit of the system and
lamp(s) and/or LED module, if any, of the complete system may be tested separately;
(b) ‘Test sample’ in the following text means correspondingly either the ‘complete system’ or the installation
unit under test;
(c) The expression ‘light source’ shall be understood to comprise also any single filament of a filament lamp,
LED modules or light emitting parts of a LED module.
The tests shall be carried out:
(a) In a dry and still atmosphere at an ambient temperature of 23 °C ± 5 °C, the test sample being mounted
on a base representing the correct installation on the vehicle;
(b) In case of replaceable light sources: using a mass production filament light source, which has been aged for
at least one hour, or a mass production gas-discharge light source, which has been aged for at least
15 hours or a mass production LED module which has been aged for at least 48 hours and cooled down
to ambient temperature before starting the tests as specified in this Regulation. The LED modules supplied
by the applicant shall be used;
(c) In the case of a system providing an adaptation of the driving-beam, the driving-beam shall be in the
maximum condition if activated.
The measuring equipment shall be equivalent to that used during type approval tests of the test samples of the
system. The system or part(s) thereof shall, prior to the subsequent tests, be set to the neutral state.
The test sample shall be operated on passing-beam without being dismounted from or readjusted in relation to
its test fixture. The light source used shall be a light source of the category specified for that headlamp.
1. Test for stability of photometric performance
1.1. Clean test sample
Each test sample shall be operated for 12 hours as described in paragraph 1.1.1 and checked as prescribed in
paragraph 1.1.2 below.
1.1.1. Test procedure
1.1.1.1. Test sequence
(a) In the case where a test sample is designed to provide only one lighting function (driving-beam or passing-
beam) and not more than one class in case of passing-beam, the corresponding light source(s) is/are lit for
the time (1) specified in paragraph 1.1 above;
(1) When the ‘test sample’ is grouped and/or reciprocally incorporated with signalling lamps, the latter shall be lit for the duration of the test,
except for a daytime running lamp. In the case of a direction indicator lamp, it shall be lit in flashing operation mode with an on/off time
ratio of approximately one to one.20.2.2019 EN Official Journal of the European Union L 49/55
(b) In the case where a test sample provides more than one function or class of passing-beam according to
this Regulation: if the applicant declares that each specified function or class of passing-beam of the test
sample has its own light source(s), being exclusively lit (2) at a time, the test shall be carried out in
accordance with this condition, activating (3) the most power consuming mode of each specified function
or class of passing-beam successively for the same (equally divided) part of the time specified in
paragraph 1.1 above.
In all other cases (3) (2), the test sample shall be subjected to the following cycle test for each, the mode(s)
of Class C passing-beam, the Class V passing-beam, the Class E passing-beam and the Class W passing-
beam, whatever is provided or partly provided by the test sample, for the same (equally divided) part of
the time specified in paragraph 1.1:
15 minutes, first, e.g. Class C passing-beam mode lit with its most power-consuming mode for straight
road conditions;
5 minutes, same passing-beam mode lit as before and, additionally, all light sources (4) of the test sample,
which are possible to be lit at the same time, according to the applicant's declaration;
After having reached the said (equally divided) part of the time specified in paragraph 1.1 above, the above
cycle test shall be performed with the second, third and fourth class of passing-beam, if applicable, in the
above order;
(c) In the case where a test sample includes other grouped lighting function(s), all the individual functions
shall be lit simultaneously for the time specified in (a) or (b) above for individual lighting functions,
according to the manufacturer's specifications;
(d) In the case of a test sample designed to provide a passing-beam bending mode or a mode or function
which is activated for a short time with an additional light source being energized, said light source shall
simultaneously be switched on for 1 minute, and switched off for 9 minutes during the activation of the
passing-beam only, specified in (a) or (b) above.
1.1.1.2. Test voltage
The voltage shall be applied to the terminals of the test sample as follows:
(a) In case of replaceable filament light source(s) operated directly under vehicle voltage system conditions: the
test shall be performed at 6,3 V, 13,2 V or 28,0 V as applicable, except if the applicant specifies that the
test sample may be used at a different voltage. In this case, the test shall be carried out with the filament
light source operated at the highest voltage that can be used.
(b) In case of replaceable gas discharge light source(s): The test voltage for the electronic light source control-
gear is 13,2 + 0,1 volts for 12 V vehicle voltage system, or otherwise specified in the application for
approval.
(c) In the case of non-replaceable light source operated directly under vehicle voltage system conditions: All
measurements on lighting units equipped with non-replaceable light sources (filament light sources and/or
others) shall be made at 6,3 V, 13,2 V or 28,0 V or at other voltages according to the vehicle voltage
system as specified by the applicant respectively.
(d) In the case of light sources, replaceable or non-replaceable, being operated independently from vehicle
supply voltage and fully controlled by the system, or, in the case of light sources supplied by a supply and
operating device, the test voltages as specified above shall be applied to the input terminals of that device.
The test laboratory may require from the manufacturer the supply and operating device or a special power
supply needed to supply the light source(s).
(2) Should additional light sources be simultaneously lit when headlamp flashing is used, this shall not be considered as being normal use of
the light sources simultaneously.
(3) When the ‘test sample’ is grouped and/or reciprocally incorporated with signalling lamps, the latter shall be lit for the duration of the test,
except for a daytime running lamp. In the case of a direction indicator lamp, it shall be lit in flashing operation mode with an on/off time
ratio of approximately one to one.
(4) All light sources of lighting functions even if no approval is sought according to this Regulation must be taken into account, except those
covered by footnote 2.L 49/56 EN Official Journal of the European Union 20.2.2019
(e) LED module(s) shall be measured at 6,3 V, 13,2 V or 28 V respectively, if not otherwise specified within
this Regulation. LED module(s) operated by an electronic light source control gear, shall be measured as
specified by the applicant.
(f) Where signalling lamps are grouped, combined or reciprocally incorporated into the test sample and
operating at voltages other than the nominal rated voltages of 6 V, 12 V or 24 V respectively, the voltage
shall be adjusted as declared by the manufacturer for the correct photometric functioning of that lamp.
1.1.2. Test results
1.1.2.1. Visual inspection:
Once the test sample has been stabilized to the ambient temperature, the test sample lens and the external
lens, if any, shall be cleaned with a clean, damp cotton cloth. It shall then be inspected visually; no distortion,
deformation, cracking or change in colour of either the test sample lens or the external lens, if any, shall be
noticeable.
1.1.2.2. Photometric test:
To comply with the requirements of this Regulation, the photometric values shall be verified in the following
points:
Class C passing-beam, and each specified other passing-beam class: 50V, B50L, and 25RR, if applicable.
Driving-beam, under neutral state conditions: point of I .
max
Another aiming may be carried out to allow for any deformation of the test sample base due to heat (the
change of the position of the cut-off line is covered in paragraph 2 of this annex).
Except for points B50L, a 10 per cent discrepancy between the photometric characteristics and the values
measured prior to the test is permissible including the tolerances of the photometric procedure. The value
measured at point B50L shall not exceed the photometric value measured prior to the test by more than
170 cd.
1.2. Dirty test sample
After being tested as specified in paragraph 1.1 above, the test sample shall be operated for one hour as
described in paragraph 1.1.1 for each function or class of passing-beam (5), after being prepared as prescribed
in paragraph 1.2.1, and checked as prescribed in paragraph 1.1.2; after each test a sufficient cooling down
period must be assured.
1.2.1. Preparation of the test sample
Test mixture
1.2.1.1. For a system or parts thereof with the outside lens in glass, a mixture of water and polluting agent to be
applied to the test sample shall be composed of:
9 parts by weight of silica sand with a particle size of 0-100 micro meter;
1 part by weight of vegetable carbon dust produced from beech wood with a particle size of 0-100 micro
meter;
0,2 parts by weight of NaCMC (6), and
5 parts by weight of sodium chloride (pure at 99 per cent);
an appropriate quantity of distilled water with a conductivity of less than 1 µS/m.
(5) The Class W passing-beam, if any, is disregarded for lighting units providing or contributing to any other passing-beam class or lighting
function.
(6) NaCMC represents the sodium salt of carboxymethylcellulose, customarily referred to as CMC. The NaCMC used in the dirt mixture shall
have a degree of substitution (DS) of 0,6-0,7 and a viscosity of 200-300 cP for a 2 per cent solution at 20 °C.20.2.2019 EN Official Journal of the European Union L 49/57
1.2.1.2. For a system or parts thereof with the outside lens in plastic material, the mixture of water and polluting agent
to be applied to the test sample shall be composed of:
(a) 9 parts by weight of silica sand with a particle size of 0-100 μm;
(b) 1 part by weight of vegetal carbon dust produced from beech wood with a particle size of 0-100 μm;
(c) 0,2 part by weight of NaCMC (7);
(d) 5 parts by weight of sodium chloride (pure at 99 per cent);
(e) 13 parts by weight of distilled water with a conductivity of ≤ 1 mS/m;
(f) 2 ± 1 drops of surfactant (8).
1.2.1.3. The mixture must not be more than 14 days old.
1.2.1.4. Application of the test mixture to the test sample
The test mixture shall be uniformly applied to the entire light-emitting surface(s) of the test sample and then
left to dry. This procedure shall be repeated until the illuminating value has dropped to 15-20 per cent of the
values measured for each following point under the conditions described in this annex:
Point I in driving beam, under neutral state conditions;
max
50V for a class C passing beam, and each specified passing beam mode.
2. Test for change in vertical position of the ‘cut-off’ line under the influence of heat
This test consists of verifying that the vertical drift of the cut-off line under the influence of heat does not
exceed a specified value for a system or part(s) of emitting a Class C (basic) passing-beam, or each specified
passing-beam mode.
If the test sample consists of more than one lighting unit or more than one assembly of lighting units which
provide a cut-off, each of these is understood to be a test sample for the purpose of this test and must be
tested separately.
The test sample tested in accordance with paragraph 1 above shall be subjected to the test described in
paragraph 2.1 below, without being removed from or readjusted in relation to its test fixture.
If the test sample has a moving optical part, only the position closest to the average vertical angular stroke
and/or the initial position according to the neutral state is chosen for this test.
The test is confined to signal input conditions corresponding to a straight road, only.
2.1. Test
For the purpose of this test, the voltage shall be adjusted as specified in paragraph 1.1.1.2 above.
The test sample shall be operated and tested on Class C passing-beam, Class V passing-beam, Class E passing-
beam and Class W passing-beam, whatever applies.
The position of the cut-off line in its horizontal part between VV and the vertical line passing through
point B50L (or R) shall be verified 3 minutes (r ) and 60 minutes (r ) respectively after operation.
3 60
The measurement of the variation in the cut-off line position as described above shall be carried out by any
method giving acceptable accuracy and reproducible results.
2.2. Test results
2.2.1. The result expressed in milliradians (mrad) shall be considered as acceptable for a passing beam headlamp
when the absolute value Δ r = | r – r | recorded on the headlamp is not more than 1,0 mrad (Δ r
1 3 60 1
≤ 1,0 mrad) upward and not more than 2,0 mrad (Δ r ≤ 2,0 mrad) downwards.
1
(7) NaCMC represents the sodium salt of carboxymethylcellulose, customarily referred to as CMC. The NaCMC used in the dirt mixture shall
have a degree of substitution (DS) of 0,6-0,7 and a viscosity of 200-300 cP for a 2 per cent solution at 20 °C.
(8) The tolerance on quantity is due to the necessity of obtaining dirt that correctly spreads out on all types of plastic lensL 49/58 EN Official Journal of the European Union 20.2.2019
2.2.2. However, if this value is:
Movement
Upward more than 1,0 mrad but not more than 1,5 mrad
(1,0 mrad < Δr ≤ 1,5 mrad)
I
Downward more than 2,0 mrad but not more than 3,0 mrad
(2,0 mrad < Δr ≤ 3,0 mrad)
I
A further sample of a headlamp mounted on a test fixture representative of the correct installation on the
vehicle shall be tested as described in paragraph 2.1 after being subjected three consecutive times to the cycle
as described below, in order to stabilize the position of mechanical parts of the headlamp:
(a) Operation of the passing beam for one hour (the voltage shall be adjusted as specified in para
graph 1.1.1.2);
(b) One hour period with the lamp switched off.
After these three cycles, the headlamp type shall be considered as acceptable if the absolute values Δr
measured according to paragraph 2.1 above on this further sample meet the requirements in paragraph 2.2.1
above.20.2.2019 EN Official Journal of the European Union L 49/59
ANNEX 5
MINIMUM REQUIREMENTS FOR CONFORMITY OF PRODUCTION CONTROL PROCEDURES
1. GENERAL
1.1. The conformity requirements shall be considered satisfied from a mechanical and a geometrical standpoint, if
the differences do not exceed inevitable manufacturing deviations within the requirements of this Regulation.
This condition also applies to colour.
1.2. With respect to photometric performances, the conformity of mass- produced systems shall not be contested if,
when testing photometric performances of any system chosen at random and equipped with a light source
energized, and if applicable corrected, as prescribed in paragraphs 1 and 2 of Annex 9 to this Regulation:
1.2.1. No value measured and corrected according to the prescriptions of paragraph 2 of Annex 9 to this Regulation
deviates unfavourably by more than 20 per cent from the value prescribed in this Regulation:
1.2.1.1. For the following values of the passing beam and its modes, the maximum unfavourable deviation may be
respectively:
(a) Maximum values at point B50L 170 cd equivalent 20 per cent and 255 cd equivalent 30 per cent;
(b) Maximum values at zone III and segment BLL: 255 cd equivalent 20 per cent and 380 cd equivalent 30 per
cent;
(c) Maximum values at segments E, F1, F2 and F3: 170 cd equivalent 20 per cent and 255 cd equivalent
30 per cent;
(d) Minimum values at BR, P, at the groups S 50+ S 50LL+ S 50RR, S 100+ S 100LL+ S 100RR, and those
required by footnote 4 of Table 1 in Annex 3 of this Regulation (B50L, BR, BRR, BLL): half of the required
value equivalent 20 per cent and three quarter of the required value equivalent 30 per cent.
1.2.1.2. For the driving-beam, HV being situated within the isolux 0,75 I , a tolerance of +20 per cent for maximum
max
values and -20 per cent for minimum values is observed for the photometric values at any measuring point
specified in paragraph 6.3.2 of this Regulation.
1.2.2. If the results of the test described above do not meet the requirements, the alignment of the system may be
changed, provided that the axis of the beam is not displaced laterally by more than 0,5 degree to the right or
left and not by more than 0,2 degree up and down, each independently and with respect to the first aiming.
These provisions do not apply to lighting units as indicated under paragraph 6.3.1.1 of this Regulation.
1.2.3. If the results of the tests described above do not meet the requirements, tests shall be repeated using another
standard (étalon) light source and/or another supply and operating device.
1.3. With respect to the verification of the change in vertical position of the ‘cut-off’ line for passing-beam under
the influence of heat, the following procedure shall be applied:
One of the sampled systems shall be tested according to the procedure described in paragraph 2.1 of Annex 4
after being subjected three consecutive times to the cycle described in paragraph 2.2.2 of Annex 4.
The system shall be considered as acceptable if Δr does not exceed 1,5 mrad.
If this value exceeds 1,5 mrad but is not more than 2,0 mrad, a second sample shall be subjected to the test
after which the mean of the absolute values recorded on both samples shall not exceed 1,5 mrad.
1.4. The chromaticity coordinates shall be conformed to.
2. MINIMUM REQUIREMENTS FOR VERIFICATION OF CONFORMITY BY THE MANUFACTURER
For each type of system the holder of the approval mark shall carry out at least the following tests, at
appropriate intervals. The tests shall be carried out in accordance with the provision of this Regulation.
If any sampling shows non-conformity with regard to the type of test concerned, further samples shall be taken
and tested. The manufacturer shall take steps to ensure the conformity of the production concerned.L 49/60 EN Official Journal of the European Union 20.2.2019
2.1. Nature of tests
Tests of conformity in this Regulation shall cover the photometric characteristics and the verification of the
change in vertical position of the cut-off line for passing-beam under the influence of heat.
2.2. Methods used in tests
2.2.1. Tests shall generally be carried out in accordance with the methods set out in this Regulation.
2.2.2. In any test of conformity carried out by the manufacturer, equivalent methods may be used with the consent of
the competent authority responsible for approval tests. The manufacturer is responsible for proving that the
applied methods are equivalent to those laid down in this Regulation.
2.2.3. The application of paragraphs 2.2.1 and 2.2.2 above requires regular calibration of test apparatus and its
correlation with measurement made by a competent authority.
2.2.4. In all cases the reference methods shall be those of this Regulation, particular for the purpose of administrative
verification and sampling.
2.3. Nature of sampling
Samples of systems shall be selected at random from the production of a uniform batch. A uniform batch
means a set of systems of the same type, defined according to the production methods of the manufacturer.
The assessment shall, in general, cover series production from individual factories. However, a manufacturer
may group together records concerning the same type from several factories provided these operate under the
same quality system and quality management.
2.4. Measured and recorded photometric characteristics
The sampled headlamps shall be subjected to photometric measurements at the points provided for in the
Regulation, the reading being limited:
To points I , HV (1), ‘HL’ and ‘HR’ (2) in the case of a driving beam;
max
To points B50L, 50L, 50V, 75R if applicable, and 25LL in the case of the passing beam(s) (see Figure 1 in
Annex 3).
2.5. Criteria governing acceptability
The manufacturer is responsible for carrying out a statistical study of the test results and for defining, in
agreement with the Type Approval Authority, criteria governing acceptability of his products in order to meet
the specification laid down for verification of conformity of products in paragraph 9.1 of this Regulation.
The criteria governing acceptability shall be such that, with a confidence level of 95 per cent, the minimum
probability of passing a spot check in accordance with Annex 7 (first sampling) would be 0,95.
(1) When the driving beam is reciprocally incorporated with the passing beam, HV in the case of the driving beam shall be the same
measuring point as in the case of the passing beam.
(2) ‘HL’ and ‘HR’: points on ‘H-H’ located at 2,6 degrees to the left and to the right of point HV respectively.20.2.2019 EN Official Journal of the European Union L 49/61
ANNEX 6
REQUIREMENTS FOR SYSTEMS INCORPORATING LENSES OF PLASTIC MATERIAL: TESTING OF LENS OR
MATERIAL SAMPLES AND COMPLETE SYSTEMS OR PART(S) OF SYSTEMS
1. GENERAL SPECIFICATIONS
1.1. The samples supplied pursuant to paragraph 2.2.4 of this Regulation shall satisfy the specifications indicated in
paragraphs 2.1 to 2.5 below.
1.2. The set of samples of complete systems or part thereof supplied pursuant to paragraph 2.2.3 of this Regulation
and incorporating lenses of plastic material shall, with regard to the lens material, satisfy the specifications
indicated in paragraph 2.6 below.
1.3. The samples of lenses of plastic material or samples of material shall be subjected, with the reflector to which
they are intended to be fitted (where applicable), to approval tests in the chronological order indicated in Table
A reproduced in Appendix 1 to this annex.
1.4. However, if the system manufacturer can prove that the product has already passed the tests prescribed in
paragraphs 2.1 to 2.5 below, or the equivalent tests pursuant to another Regulation, those tests do not need to
be repeated; only the tests prescribed in Appendix 1, Table B, shall be mandatory.
1.5. If the system or part thereof is designed for right-hand installation only, or for left-hand installation only, tests
pursuant to this annex may be done on one sample only, at the choice of the applicant.
2. TESTS
2.1. Resistance to temperature changes
2.1.1. Tests
Three new samples (lenses) shall be subjected to five cycles of temperature and humidity (RH = relative
humidity) change in accordance with the following programme:
3 hours at 40 °C ± 2 °C and 85-95 per cent RH;
1 hour at 23 °C ± 5 °C and 60-75 per cent RH;
15 hours at – 30 °C ± 2 °C;
1 hour at 23 °C ± 5 °C and 60-75 per cent RH;
3 hours at 80 °C ± 2 °C;
1 hour at 23 °C ± 5 °C and 60-75 per cent RH;
Before this test, the samples shall be kept at 23 °C ± 5 °C and 60-75 per cent RH for at least four hours.
Note: The periods of one hour at 23 °C ± 5 °C shall include the periods of transition from one temperature to
another which are needed in order to avoid thermal shock effects.
2.1.2. Photometric measurements
2.1.2.1. Method
Photometric measurements shall be carried out on the samples before and after the test.
These measurements shall be made according to Annex 9 to this Regulation, at the following points:
B50L and 50V for the class C passing beam lighting;
I for the driving beam of a system.
max
2.1.2.2. Results
The variation between the photometric values measured on each sample before and after the test shall not
exceed 10 per cent including the tolerances of the photometric procedure.L 49/62 EN Official Journal of the European Union 20.2.2019
2.2. Resistance to atmospheric and chemical agents
2.2.1. Resistance to atmospheric agents
Three new samples (lenses or samples of material) shall be exposed to radiation from a source having a spectral
energy distribution similar to that of a black body at a temperature between 5 500 K and 6 000 K.
Appropriate filters shall be placed between the source and the samples so as to reduce as far as possible
radiation with wave lengths smaller than 295 nm and greater than 2 500 nm. The samples shall be exposed to
an energetic illumination of 1 200 W/m2 ± 200 W/m2 for a period such that the luminous energy that they
receive is equal to 4 500 MJ/m2 ± 200 MJ/m2. Within the enclosure, the temperature measured on the black
panel placed on a level with the samples shall be 50 °C ± 5 °C. In order to ensure a regular exposure, the
samples shall revolve around the source of radiation at a speed between 1 and 5 min– 1.
The samples shall be sprayed with distilled water of conductivity lower than 1 mS/m at a temperature of
23 °C ± 5 °C, in accordance with the following cycle:
Spraying: 5 minutes; drying: 25 minutes.
2.2.2. Resistance to chemical agents
After the test described in paragraph 2.2.1 above and the measurement described in paragraph 2.2.3.1 below
have been carried out, the outer face of the said three samples shall be treated as described in
paragraph 2.2.2.2 with the mixture defined in paragraph 2.2.2.1 below.
2.2.2.1. Test mixture
The test mixture shall be composed of 61,5 per cent n-heptane, 12,5 per cent toluene, 7,5 per cent ethyl
tetrachloride, 12,5 per cent trichloroethylene and 6 per cent xylene (volume per cent).
2.2.2.2. Application of the test mixture
Soak a piece of cotton cloth (as per ISO 105) until saturation with the mixture defined in paragraph 2.2.2.1
above and, within 10 seconds, apply it for 10 minutes to the outer face of the sample at a pressure of
50 N/cm2, corresponding to an effort of 100 N applied on a test surface of 14 × 14 mm.
During this 10-minute period, the cloth pad shall be soaked again with the mixture so that the composition of
the liquid applied is continuously identical with that of the test mixture prescribed.
During the period of application, it is permissible to compensate the pressure applied to the sample in order to
prevent it from causing cracks.
2.2.2.3. Cleaning
At the end of the application of the test mixture, the samples shall be dried in the open air and then washed
with the solution described in paragraph 2.3 (Resistance to detergents and hydrocarbons) at 23 °C ± 5 °C.
Afterwards the samples shall be carefully rinsed with distilled water containing not more than 0,2 per cent
impurities at 23 °C ± 5 °C and then wiped off with a soft cloth.
2.2.3. Results
2.2.3.1. After the test of resistance to atmospheric agents, the outer face of the samples shall be free from cracks,
scratches, chipping and deformation, and the mean variation in transmission Δt = (T – T )/T measured on the
2 3 2
three samples according to the procedure described in Appendix 2 to this annex shall not exceed 0,020
(Δt < 0,020).
m
2.2.3.2. After the test of resistance to chemical agents, the samples shall not bear any traces of chemical staining likely
to cause a variation of flux diffusion, whose mean variation Δd = (T – T )/T measured on the three samples
5 4 2
according to the procedure described in Appendix 2 to this annex shall not exceed 0,020 (Δd < 0,020).
m
2.2.4. Resistance to light source radiation
If necessary the following test shall be done:
Flat samples of each light transmitting plastic component of the system are exposed to the light of the light
source. The parameters such as angles and distances of those samples shall be the same as in the system. These
samples shall have the same colour and surface treatment, if any, as the parts of the system.20.2.2019 EN Official Journal of the European Union L 49/63
After 1 500 hours of continuous exposure, the colorimetric specification of the transmitted light must be met
with a new light source, and the surface of the samples shall be free of cracks, scratches, scaling or
deformation.
The UV-resistance testing of internal materials to light source radiation is not necessary if light sources
according to Regulation No 37 and/or low-UV-type gas discharge light sources and/or low-UV-type LED
modules are being applied or if provisions are taken, to shield the relevant system components from UV
radiation, e.g. by glass filters.
2.3. Resistance to detergents and hydrocarbons
2.3.1. Resistance to detergents
The outer face of three samples (lenses or samples of material) shall be heated to 50 °C ± 5 °C and then
immersed for five minutes in a mixture maintained at 23 °C ± 5 °C and composed of 99 parts distilled water
containing not more than 0,02 per cent impurities and one part alkylaryl sulphonate.
At the end of the test, the samples shall be dried at 50 °C ± 5 °C. The surface of the samples shall be cleaned
with a moist cloth.
2.3.2. Resistance to hydrocarbons
The outer face of these three samples shall then be lightly rubbed for one minute with a cotton cloth soaked in
a mixture composed of 70 per cent n-heptane and 30 per cent toluene (volume per cent), and shall then be
dried in the open air.
2.3.3. Results
After the above two tests have been performed successively, the mean value of the variation in transmission
Δt = T – T )/T measured on the three samples according to the procedure described in Appendix 2 to this
2 3 2
annex shall not exceed 0,010 (Δt ≤ 0,010).
m
2.4. Resistance to mechanical deterioration
2.4.1. Mechanical deterioration method
The outer face of the three new samples (lenses) shall be subjected to the uniform mechanical deterioration test
by the method described in Appendix 3 to this annex.
2.4.2. Results
After this test, the variations:
In transmission: Δt = (T – T )/T
2 3 2
And in diffusion: Δd = (T – T )/T
5 4 2
Shall be measured according to the procedure described in Appendix 2 in the area specified in
paragraph 2.2.4.1.1 of this Regulation. The mean value of the three samples shall be such that:
Δt ≤ 0,100; Δd ≤ 0,050.
m m
2.5. Test of adherence of coatings, if any
2.5.1. Preparation of the sample
A surface of 20 mm × 20 mm in area of the coating of a lens shall be cut with a razor blade or a needle into
a grid of squares approximately 2 mm × 2 mm. The pressure on the blade or needle shall be sufficient to cut at
least the coating.
2.5.2. Description of the test
Use an adhesive tape with a force adhesion of 2 N/(cm of width) ± 20 per cent measured under the
standardized conditions specified in Appendix 4 to this annex. This adhesive tape, which shall be at least
25 mm wide, shall be pressed for at least five minutes to the surface prepared as prescribed in paragraph 2.5.1
above.
Then the end of the adhesive tape shall be loaded in such a way that the force of adhesion to the surface
considered is balanced by a force perpendicular to that surface. At this stage, the tape shall be torn off at
a constant speed of 1,5 m/s ± 0,2 m/s.L 49/64 EN Official Journal of the European Union 20.2.2019
2.5.3. Results
There shall be no appreciable impairment of the gridded area. Impairments at the intersections between squares
or at the edges of the cuts shall be permitted, provided that the impaired area does not exceed 15 per cent of
the gridded surface.
2.6. Tests of the complete system incorporating a lens of plastic material
2.6.1. Resistance to mechanical deterioration of the lens surface
2.6.1.1. Tests
The lens of system sample No 1 shall be subjected to the test described in paragraph 2.4.1 above.
2.6.1.2. Results
After the test, the results of photometric measurements carried out on the system or part thereof in accordance
with this Regulation shall not exceed by more than 30 per cent the maximum values prescribed at point B50L
and not be more than 10 per cent below the minimum values prescribed at point 75R, if applicable.
2.6.2. Test of adherence of coatings, if any
The lens of installation unit sample No 2 shall be subjected to the test described in paragraph 2.5 above.
3. VERIFICATION OF THE CONFORMITY OF PRODUCTION
3.1. With regard to the materials used for the manufacture of lenses, the installation units of a series shall be
recognized as complying with this Regulation if:
3.1.1. After the test for resistance to chemical agents and the test for resistance to detergents and hydrocarbons, the
outer face of the samples exhibits no cracks, chipping or deformation visible to the naked eye (see
paragraphs 2.2.2, 2.3.1 and 2.3.2 of this annex);
3.1.2. After the test described in paragraph 2.6.1.1 above, the photometric values at the points of measurement
considered in paragraph 2.6.1.2 are within the limits prescribed for conformity of production by this
Regulation.
3.2. If the test results fail to satisfy the requirements, the tests shall be repeated on another sample of systems
selected at random.20.2.2019 EN Official Journal of the European Union L 49/65
Appendix 1
CHRONOLOGICAL ORDER OF APPROVAL TESTS
A. TESTS ON PLASTIC MATERIALS (LENSES OR SAMPLES OF MATERIAL SUPPLIED PURSUANT TO PARAGRAPH 2.2.4 OF THIS
REGULATION)
Samples Lenses or samples of material Lenses
Tests 1 2 3 4 5 6 7 8 9 10 11 12 13 14
1.1. Limited photometry (para. 2.1.2) X X X
1.1.1. Temperature change (para. 2.1.1) X X X
1.2. Limited photometry (para. 2.1.2) X X X
1.2.1. Transmission measurement X X X X X X X X X
1.2.2. Diffusion measurement X X X X X X
1.3. Atmospheric agents (para. 2.2.1) X X X
1.3.1. Transmission measurement X X X
1.4. Chemical agents (para. 2.2.2) X X X
1.4.1. Diffusion measurement X X X
1.5. Detergents (para. 2.3.1) X X X
1.6. Hydrocarbons (para. 2.3.2) X X X
1.6.1. Transmission measurement X X X
1.7. Deterioration (para. 2.4.1) X X X
1.7.1. Transmission measurement X X X
1.7.2. Diffusion measurement X X X
1.8. Adherence (para. 2.5) X
1.9. Resistance to light source radiation
X
(para. 2.2.4)
B. TESTS ON COMPLETE SYSTEMS OR PART(S) THEREOF (SUPPLIED PURSUANT TO PARAGRAPH 2.2.3 OF THIS REGULATION).
Complete systems
Tests Sample No
1 2
2.1. Deterioration (para. 2.6.1.1) X
2.2. Photometry (para. 2.6.1.2) X X
2.3. Adherence (para. 2.6.2)L 49/66 EN Official Journal of the European Union 20.2.2019
Appendix 2
METHOD OF MEASUREMENT OF THE DIFFUSION AND TRANSMISSION OF LIGHT
1. EQUIPMENT (see Figure 1 below)
The beam of a collimator K with a half divergence β/2 = 17,4 × 10 – 4 rad is limited by a diaphragm D with an
τ
opening of 6 mm against which the sample stand is placed.
A convergent achromatic lens L , corrected for spherical aberrations links the diaphragm D with the receiver R; the
2 τ
diameter of the lens L shall be such that it does not diaphragm the light diffused by the sample in a cone with a half
2
top angle of β/2 = 14 degrees.
An annular diaphragm D , with angles α/2 = 1 deg and α /2 = 12 degrees is placed in an image focal plane of the
D o max
lens L .
2
The non-transparent central part of the diaphragm is necessary in order to eliminate the light arriving directly from
the light source. It shall be possible to remove the central part of the diaphragm from the light beam in such
a manner that it returns exactly to its original position.
The distance L D and the focal length F of the lens L shall be so chosen that the image of D completely covers the
2 τ 2 2 τ
receiver R.
For L it is recommended to use a focal distance of about 80 mm.
2
When the initial incident flux is referred to 1 the absolute precision of each reading shall be better than 0,001.
Figure 1
Optical set up for measurement of variations in diffusion and transmission
2. MEASUREMENTS
The following readings shall be taken:
Reading With sample With central part of D Quantity represented
D
T No No Incident flux in initial reading
1
Yes Flux transmitted by the new material in a field of
T No
2 (before test) 24 degrees
Yes Flux transmitted by the tested material in a field
T No
3 (before test) of 24 degrees
Yes
T Yes Flux diffused by the new material
4 (before test)
Yes
T Yes Flux diffused by the tested material
5 (before test)20.2.2019 EN Official Journal of the European Union L 49/67
Appendix 3
SPRAY TESTING METHOD
1. TEST EQUIPMENT
1.1. Spray gun
The spray gun used shall be equipped with a nozzle 1,3 mm in diameter allowing a liquid flow rate of
0,24 ± 0,02 l/minute at an operating pressure of 6,0 bars – 0/+ 0,5 bar.
Under these operation conditions the fan pattern obtained shall be 170 mm ± 50 mm in diameter on the surface
exposed to deterioration, at a distance of 380 mm ± 10 mm from the nozzle.
1.2. Test mixture
The test mixture shall be composed of:
Silica sand of hardness 7 on the Mohs scale, with a grain size between 0 and 0,2 mm and an almost normal
distribution, with an angular factor of 1,8 to 2;
Water of hardness not exceeding 205 g/m3 for a mixture comprising 25 g of sand per litre of water.
2. TEST
The outer surface of the lamp lenses shall be subjected once or more than once to the action of the sand jet
produced as described above. The jet shall be sprayed almost perpendicular to the surface to be tested.
The deterioration shall be checked by means of one or more samples of glass placed as a reference near the lenses
to be tested. The mixture shall be sprayed until the variation in the diffusion of light on the sample or samples
measured by the method described in Appendix 2, is such that: Δd = (T – T )/T = 0,0250 ± 0,0025.
5 4 2
Several reference samples may be used to check that the whole surface to be tested has deteriorated homoge
neously.L 49/68 EN Official Journal of the European Union 20.2.2019
Appendix 4
ADHESIVE TAPE ADHERENCE TEST
1. PURPOSE
This method allows to determine under standard conditions the linear force of adhesion of an adhesive tape to
a glass plate.
2. PRINCIPLE
Measurement of the force necessary to unstick an adhesive tape from a glass plate at an angle of 90 degrees.
3. SPECIFIED ATMOSPHERIC CONDITIONS
The ambient conditions shall be at 23 °C ± 5 °C and 65 ± 15 per cent relative humidity.
4. TEST PIECES
Before the test, the sample roll of adhesive tape shall be conditioned for 24 hours in the specified atmosphere (see
paragraph 3 above).
Five test pieces each 400 mm long shall be tested from each roll. These test pieces shall be taken from the roll after
the first three turns were discarded.
5. PROCEDURE
The test shall be performed under the ambient conditions specified in paragraph 3 above.
Take the five test pieces while unrolling the tape radially at a speed of approximately 300 mm/s, then apply them
within 15 seconds in the following manner:
Apply the tape to the glass plate progressively with a slight length- wise rubbing movement of the finger, without
excessive pressure, in such a manner as to leave no air bubble between the tape and the glass plate.
Leave the assembly in the specified atmospheric conditions for 10 minutes.
Unstick about 25 mm of the test piece from the plate in a plane perpendicular to the axis of the test piece.
Fix the plate and fold back the free end of the tape at 90 degrees. Apply force in such a manner that the separation
line between the tape and the plate is perpendicular to this force and perpendicular to the plate.
Pull to unstick at a speed of 300 mm/s ± 30 mm/s and record the force required.
6. RESULTS
The five values obtained shall be arranged in order and the median value taken as a result of the measurement. This
value shall be expressed in Newton per centimetre of width of the tape.20.2.2019 EN Official Journal of the European Union L 49/69
ANNEX 7
MINIMUM REQUIREMENTS FOR SAMPLING BY AN INSPECTOR
1. GENERAL
1.1. The conformity requirements shall be considered satisfied from a mechanical and a geometrical standpoint, if
the differences do not exceed inevitable manufacturing deviations within the requirements of this Regulation.
This condition also applies to colour.
1.2. With respect to photometric performances, the conformity of mass- produced systems shall not be contested
if, when testing photometric performances of any system chosen at random and equipped with a light source
energized, and if applicable corrected, as prescribed in paragraphs 1 and 2 of Annex 9 to this Regulation:
1.2.1. No value deviates unfavourably by more than 20 per cent from the value prescribed in this Regulation;
1.2.1.1. For the following values of the passing beam and its modes, the maximum unfavourable deviation may be
respectively:
(a) Maximum values at point B50L 170 cd equivalent 20 per cent and 255 cd equivalent 30 per cent;
(b) Maximum values at zone III and segment BLL: 255 cd equivalent 20 per cent and 380 cd equivalent
30 per cent;
(c) Maximum values at segments E, F1, F2 and F3: 170 cd equivalent 20 per cent and 255 cd equivalent
30 per cent;
(d) Minimum values at BR, P, at the groups S50 + S50LL + S50RR, S100 + S100LL + S100RR, and those
required by footnote 4 of Table 1 in Annex 3 of this Regulation (B50L, BR, BRR, BLL): half of the required
value is equivalent to 20 per cent and three quarters of the required value equivalent to 30 per cent.
1.2.1.2. For the driving-beam, HV being situated within the isolux 0,75 I , a tolerance of + 20 per cent for maximum
max
values and -20 per cent for minimum values is observed for the photometric values at any measuring point
specified in paragraph 6.3.2 of this Regulation.
1.2.2. If the results of the test described above do not meet the requirements, the alignment of the system may be
changed, provided that the axis of the beam is not displaced laterally by more than 0,5 degree to the right or
left and not by more than 0,2 degree up and down. These provisions do not apply to lighting units as
indicated under paragraph 6.3.1.1 of this Regulation.
1.2.3. If the results of the tests described above do not meet the requirements, tests shall be repeated using another
standard (étalon) light source and/or another supply and operating device.
1.2.4. Systems with apparent defects are disregarded.
1.2.5. The reference mark is disregarded.
2. FIRST SAMPLING
In the first sampling four systems are selected at random. The first sample of two is marked A, the second
sample of two is marked B.
2.1. The conformity is not contested
2.1.1. Following the sampling procedure shown in Figure 1 of this annex the conformity of mass-produced systems
shall not be contested if the deviations of the measured values of the systems in the unfavourable directions
are:
2.1.1.1. Sample A
A1: one system 0 per cent
one system not more than 20 per cent
A2: both systems more than 0 per cent
but not more than 20 per cent
Go to sample BL 49/70 EN Official Journal of the European Union 20.2.2019
2.1.1.2. Sample B
B1: both systems 0 per cent
2.1.2. Or if the conditions of paragraph 1.2.2 above for sample A are fulfilled.
2.2. The conformity is contested
2.2.1. Following the sampling procedure shown in Figure 1 of this annex the conformity of mass-produced systems
shall be contested and the manufacturer requested to make his production meet the requirements (alignment) if
the deviations of the measured values of the systems are:
2.2.1.1. Sample A
A3: one system not more than 20 per cent
one system more than 20 per cent
but not more than 30 per cent
2.2.1.2. Sample B
B2: in the case of A2
one system more than 0 per cent
but not more than 20 per cent
one system not more than 20 per cent
B3: in the case of A2
one system 0 per cent
one system more than 20 per cent
but not more than 30 per cent
2.2.2. Or if the conditions of paragraph 1.2.2 above for sample A are not fulfilled.
2.3. Approval withdrawn
Conformity shall be contested and paragraph 10 of this Regulation applied if, following the sampling
procedure shown in Figure 1 of this annex, the deviations of the measured values of the systems are:
2.3.1. Sample A
A4: one system not more than 20 per cent
one system more than 30 per cent
A5: Both systems more than 20 per cent
2.3.2. Sample B
B4: in the case of A2
one system more than 0 per cent
but not more than 20 per cent
one system more than 20 per cent
B5: in the case of A2
both systems more than 20 per cent
B6: in the case of A2
one system 0 per cent
one system more than 30 per cent
2.3.3. Or if the conditions of paragraph 1.2.2 above for samples A and B are not fulfilled.20.2.2019 EN Official Journal of the European Union L 49/71
3. REPEATED SAMPLING
In the case of A3, B2, B3 a repeated sampling, third sample C of two systems and fourth sample D of two
systems, selected from stock manufactured after alignment, is necessary within two months' time after the
notification.
3.1. The conformity is not contested
3.1.1. Following the sampling procedure shown in Figure 1 of this annex the conformity of mass-produced shall not
be contested if the deviations of the measured values of the systems are:
3.1.1.1. Sample C
C1: one system 0 per cent
one system not more than 20 per cent
C2: both systems more than 0 per cent
but not more than 20 per cent
Go to sample D
3.1.1.2. Sample D
D1: in the case of C2
both systems 0 per cent
3.1.2. Or if the conditions of paragraph 1.2.2 above for sample C are fulfilled.
3.2. The conformity is contested
3.2.1. Following the sampling procedure shown in Figure 1 of this annex the conformity of mass-produced systems
shall be contested and the manufacturer requested to make his production meet the requirements (alignment) if
the deviations of the measured values of the systems are:
3.2.1.1. Sample D
D2: in the case of C2
one system more than 0 per cent
but not more than 20 per cent
one system not more than 20 per cent
3.2.1.2. Or if the conditions of paragraph 1.2.2 for sample C are not fulfilled.
3.3. Approval withdrawn
Conformity shall be contested and paragraph 10. of this Regulation applied if, following the sampling
procedure shown in Figure 1 of this annex, the deviations of the measured values of the systems are:
3.3.1. Sample C
C3: one system not more than 20 per cent
one system more than 20 per cent
C4: both systems both systems both systems
3.3.2. Sample D
D3: in the case of C2
one system 0 per cent
or more than 0 per cent
one system more than 20 per cent
3.3.3. Or if the conditions of paragraph 1.2.2 above for samples C and D are not fulfilled.
4. CHANGE OF THE VERTICAL POSITION OF THE CUT-OFF LINE FOR PASSING-BEAM
With respect to the verification of the change in vertical position of the cut-off line for passing-beam under
the influence of heat, the following procedure shall be applied:
One of the systems of sample A after sampling procedure in Figure 1 of this annex shall be tested according to
the procedure described in paragraph 2.1 of Annex 4 after being subjected three consecutive times to the cycle
described in paragraph 2.2.2 of Annex 4.L 49/72 EN Official Journal of the European Union 20.2.2019
The system shall be considered as acceptable if Δr does not exceed 1,5 m rad upwards and does not exceed
2,5 mrad downwards.
If this value exceeds 1,5 mrad but is not more than 2,0 mrad upwards or exceeds 2,5 mrad but is not more
than 3,0 mrad downwards, the second system of sample A shall be subjected to the test after which the mean
of the absolute values recorded on both samples shall not exceed 1,5 m rad upwards and shall not exceed
2,5 mrad downwards.
However, if this value of 1,5 mrad upwards and 2,5 mrad downwards on sample A is not complied with, the
two systems of sample B shall be subjected to the same procedure and the value of Δr for each of them shall
not exceed 1,5 mrad upwards and shall not exceed 2,5 mrad downwards.
Figure 1
Note: ‘device’ in this figure means ‘system’.20.2.2019 EN Official Journal of the European Union L 49/73
ANNEX 8
PASSING-BEAM ‘CUT-OFF’ AND AIMING PROVISIONS
1. CUT-OFF DEFINITION
The ‘cut-off’, when projected on the aiming screen shall be sufficiently sharp to permit aiming; it shall comply
with the following requirements.
1.1. Shape (see Figure 1)
The ‘cut-off’ shall provide:
(a) A straight ‘horizontal part’ towards the left;
(b) A raised ‘elbow – shoulder’ part towards the right.
In each case the ‘elbow – shoulder’ part shall have a sharp edge.
2. VISUAL AIMING PROCEDURE
2.1. The system shall, prior to the subsequent test procedures, be set to the neutral state. The instructions below apply
to the beams of those lighting units, which are specified by the applicant to be aimed.
2.2. The beam shall be visually aimed by means of the ‘cut-off’ (see Figure 1 below). The aiming shall be carried out
using a flat vertical screen set up at a distance of 10 m or 25 m (as indicated in section 9 of Annex 1) forward of
the headlamp and at right angles to the H-V axis. The screen shall be sufficiently wide to allow examination and
adjustment of the ‘cut-off’ of the passing-beam over at least 5° on either side of the V-V line.
2.3. For vertical adjustment: the horizontal part of the ‘cut-off’ is moved upward from below line B and adjusted to its
nominal position one per cent (25 cm) below the H-H line.
Figure 1
Note: The scales are different for vertical and horizontal lines.
2.4. For horizontal adjustment: the ‘elbow–shoulder’ part of the ‘cut-off’ shall be moved:
For right hand traffic:
(a) From right to left and shall be horizontally positioned after its movement so that:
(i) Above the line 0,2° D its ‘shoulder’ shall not exceed the line A to the left, andL 49/74 EN Official Journal of the European Union 20.2.2019
(ii) On the line 0,2° D or below its ‘shoulder’ should cross the line A, and
(iii) The kink of the ‘elbow’ is basically located within +/- 0,5 degree to the left or right of the V-V line.
Or
For left hand traffic:
(b) From left to right and shall be horizontally positioned after its movement so that:
(i) Above the line 0,2° D its ‘shoulder’ shall not exceed the line A to the right, and
(ii) On the line 0,2° D or below its ‘shoulder’ should cross the line A, and
(iii) The kink of the ‘elbow’ is basically located within +/- 0,5 degree to the left or right of the V-V line.
2.5. Where a headlamp so aimed does not meet the requirements set out in Annex 3 its alignment may be changed,
provided that the axis of the beam is not displaced:
Horizontally, from line A by more than: 0,5° to the left or 0,75° to the right;
Vertically not more than 0,25° up or down from line B.
2.6. If, however, vertical adjustment cannot be performed repeatedly to the required position within the tolerances
described in paragraph 2.5 above, the instrumental method described in paragraph 3 below shall be applied to
test compliance with the required minimum quality of the ‘cut-off’ (as defined in paragraph 2.7 below) and to
perform the vertical and horizontal adjustment of the beam.
2.7. Measurement of the quality of the ‘cut-off’
To determine the minimum sharpness, measurements shall be performed by vertically scanning through the
horizontal part of the ‘cut-off’ in angular steps of 0,05° at either a measurement distance of:
(a) 10 m with a detector having a diameter of approximately 10 mm or
(b) 25 m with a detector having a diameter of approximately 30 mm.
The measuring distance at which the test was carried out shall be recorded in item 9.8 of the communication
form (see Annex 1 to this Regulation).
To determine the maximum sharpness, measurements shall be performed by vertically scanning through the
horizontal part of the ‘cut-off’ in angular steps of 0,05° exclusively at a measurement distance of 25 m and with
a detector having a diameter of approximately 30 mm.
The ‘cut-off’ quality shall be considered acceptable if the requirements of paragraph 2.1 to 2.3 above comply with
at least one set of measurements.
2.7.1. Not more than one ‘cut-off’ shall be visible (1).
2.7.2. Sharpness of ‘cut-off’
The sharpness factor G is determined by scanning vertically through the horizontal part of the ‘cut-off’ at 2,5°
from the V-V where:
G = (log Ε - log E ) where β = the vertical position in degrees.
β (β + 0,1°)
The value of G shall not be less than 0,13 (minimum sharpness) and not greater than 0,40 (maximum
sharpness).
2.7.3. Linearity
The part of the horizontal ‘cut-off’ that serves for vertical adjustment shall be horizontal between 1,5° and 3,5°
from the V-V line (see Figure 1a of paragraph 3 below):
(a) The inflection points of the ‘cut-off’ gradient at the vertical lines at 1,5°, 2,5° and 3,5° shall be determined by
the equation:
(d2 (log E)/dβ2 = 0).
(b) The maximum vertical distance between the inflection points determined shall not exceed 0,2°.
(1) This paragraph should be amended when an objective test method is available.20.2.2019 EN Official Journal of the European Union L 49/75
2.8. If a partial beam provides a horizontal ‘cut-off’ only: no special requirements for horizontal adjustment apply if
not specified by the applicant.
2.9. Any ‘cut-off’ of a lighting unit not designed to be separately aimed, according to the applicants specification,
must comply with the relevant requirements.
2.10. Lighting units when aimed using a method specified by the applicant in accordance with the provisions of the
paragraphs 5.2 and 6.2.1.1 of this Regulation: the shape and position of the ‘cut-off’, if any, shall comply with
the respective requirements of Table 2 of Annex 3 to this Regulation.
2.11. For each further mode of passing-beam, the shape and position of the ‘cut-off’, if any, shall comply automatically
with the respective requirements of Table 2 of Annex 3. to this Regulation.
2.12. A separate initial aiming and/or adjustment process according to the applicant's specification, based on the
provisions of paragraphs 2.1 through 2.6 above, may apply to lighting units intended to be installed separately.
3. VERTICAL AND HORIZONTAL ADJUSTMENT
If the ‘cut-off’ complies with the quality requirements of paragraph 2 of this Annex, the beam adjustment may be
performed instrumentally.
Figure 1a
Measurement of ‘cut-off’ quality
Note: The scales are different for vertical and horizontal lines.
3.1. Vertical adjustment
Moving upward from below the line B (see Figure 2 below), a vertical scan is carried out through the horizontal
part of the ‘cut-off’ at 2,5° from V-V. The inflection point (where d2 (log E)/dv2 = 0) is determined and positioned
on the line B situated one per cent below H-H.
3.2. Horizontal adjustment
The applicant shall specify one of the following horizontal aim methods:
(a) The ‘0,2 D line’ method (see Figure 2 below).
A single horizontal line at 0,2° D shall be scanned from 5° left to 5° right after the lamp has been aimed
vertically. The maximum gradient ‘G’ determined using the formula G = (log Ε – log E ) where β is the
β (β + 0,1°)
horizontal position in degrees, shall not be less than 0,08.
The inflection point found on the 0,2 D line shall be positioned on the line A.L 49/76 EN Official Journal of the European Union 20.2.2019
Figure 2
Instrumental vertical and horizontal adjustment — Horizontal line scan method
Note: The scales are different for vertical and horizontal lines.
(b) The ‘3 line’ method (see Figure 3 below)
Three vertical lines shall be scanned from 2° D to 2° U at 1° R, 2° R, and 3° R after the lamp has been aimed
vertically. The respective maximum gradients ‘G’ determined using the formula:
G = (log Ε – log E )
β (β + 0,1°)
Where β is the vertical position in degrees shall not be less than 0,08. The inflection points found on the
three lines shall be used to derive a straight line. The intersection of this line and the line B found while
performing vertical aim shall be placed on the V line.
Figure 3
Instrumental vertical and horizontal adjustment — Three line scan method
Note: The scales are different for vertical and horizontal lines.20.2.2019 EN Official Journal of the European Union L 49/77
ANNEX 9
PHOTOMETRIC MEASUREMENT PROVISIONS
1. GENERAL PROVISIONS
1.1. The system or part(s) thereof shall be mounted on a gonio(photo)meter system.
1.2. The luminous intensity values shall be determined by means of a photoreceptor contained within a square of
65 mm side and set up to a distance of at least 25 m forward of the centre of reference of each lighting unit
perpendicular to the measurement axis from the origin of the gonio(photo)meter system.
1.3. During photometric measurements, stray reflections should be avoided by appropriate masking.
1.4. The luminous intensities are measured at a nominal distance of 25 m.
1.5. The angular coordinates are specified in degrees on a sphere corresponding to a gonio(photo)meter system as
defined in Regulation No 48 (see Diagram 1).
Diagram 1
1.6. Any equivalent photometric method is acceptable, if the accordingly applicable correlation is observed.
1.7. Any offset of the centre of reference of each lighting unit, with respect to the goniometer rotation axes, should
be avoided. This applies especially to the vertical direction and to lighting units producing a ‘cut-off’.
An aiming screen shall be used and may be located at a shorter distance than that of the photoreceptor.
1.8. The photometric requirements for each single measuring point (angular position) of a lighting function or
mode as specified in this Regulation apply to half of the sum of the respective measured values from all
lighting units of the system applied for this function or mode, or, from all lighting units as indicated in the
respective requirement;L 49/78 EN Official Journal of the European Union 20.2.2019
1.8.1. However in those cases where a provision is specified for one side only, the division by the factor of 2 does not
apply. These cases are: paragraphs 6.2.5.2, 6.2.8.1, 6.3.2.1.1, 6.3.2.1.2, 6.3.4.1, 6.4.6 and footnote 4 of Table 1
of Annex 3.
1.9. The lighting units of the system shall be measured individually; however, simultaneous measurements may be
performed on two or more lighting units of an installation unit, being equipped with the same light source
types with respect to their power supply (either power controlled or not), if they are sized and situated such,
that their illuminating surfaces are completely contained in a rectangle of not more than 300 mm in horizontal
extend and not more than 150 mm vertical extend, and, if a common centre of reference is specified by the
manufacturer.
1.10. The system shall prior to the subsequent test procedures be set to the neutral state.
1.11. The system or part(s) thereof shall be so aimed before starting the measurements that the position of the ‘cut-
off’ complies with the requirements indicated in the Table 2 of Annex 3 to this Regulation. Parts of a system
measured individually and having no ‘cut-off’ shall be installed on the goniometer under the conditions
(mounting position) specified by the applicant.
2. MEASUREMENT CONDITIONS WITH RESPECT TO LIGHT SOURCES
2.1. In the case of replaceable filament lamps operated directly under vehicle voltage system conditions:
The system or parts thereof shall be checked by means of an uncoloured standard (étalon) filament lamp(s)
designed for a rated voltage of 12 V. During checking of the system or part of, the voltage at the terminals of
the filament lamp(s) shall be regulated so as to obtain the reference luminous flux 13,2 volts as indicated at the
relevant data sheet of Regulation No 37.
For the measurements, the flux of this filament lamp may differ from the reference luminous flux at 13,2 V
specified in Regulation No 37. In this case, the luminous intensity shall be corrected accordingly by the
individual factor of the standard (étalon) filament lamp (F = Φ ./Φ (Voltage)).
obj
The system or parts thereof shall be considered acceptable if the requirements of paragraph 6. of this
Regulation are met with at least one standard (étalon) filament lamp, which may be submitted with the system.
2.2. In the case of a replaceable gas-discharge light source:
The voltage applied at the terminals of the ballast(s) or at the terminals of the light source(s) in case the ballast
is integrated with the light source, is 13,2 V +/- 0,1 for 12 V systems.
The system or parts thereof using a replaceable gas-discharge light source shall comply with the photometric
requirements set out in the relevant paragraphs of this Regulation with at least one standard (étalon) light
source, which has been aged during at least 15 cycles, as specified in Regulation No 99. The luminous flux of
this gas-discharge light source may differ from the objective luminous flux specified in Regulation No 99.
In this case, the measured photometric values shall be corrected accordingly.
2.3. In the case of a non-replaceable light source operating directly under vehicle voltage system conditions:
All measurements on lamps equipped with non-replaceable light sources (filament lamps and other) shall be
made at 6,3 V, 13,2 V or 28,0 V, or at a voltage as specified by the applicant with respect to any other vehicle
voltage system.
2.4. In the case of a light source, replaceable or non-replaceable, which is operated independently from vehicle
supply voltage and fully controlled by the system, or in the case of a light source supplied by a special power
supply, the test voltage as specified in paragraph 2.3 above shall be applied to the input terminals of that
system/power supply. The test laboratory may require from the manufacturer this special power supply needed
to supply the light sources.
2.5. LED module(s) shall be measured at 6,3 V, 13,2 V or 28,0 V respectively, if not otherwise specified within this
Regulation. LED module(s) operated by an electronic light source control gear, shall be measured as specified by
the applicant.20.2.2019 EN Official Journal of the European Union L 49/79
3. MEASUREMENT CONDITIONS WITH RESPECT TO BENDING MODES
3.1. In the case of a system or part(s) thereof, which provide a bending mode, the requirements of paragraphs 6.2
(passing-beam), and/or 6.3 (driving-beam) of this Regulation apply for all states, corresponding to the turn
radius of the vehicle. For verification with respect to the passing-beam and the driving-beam the following
procedure shall be used:
3.1.1. The system shall be tested in the neutral state (central/straight), and, in addition in the state(s) corresponding to
the smallest turn radius of the vehicle in both directions using the signal generator, if applicable.
3.1.1.1. Compliance with the requirements of paragraphs 6.2.5.2 and 6.2.5.4.1 of this Regulation shall be checked for
both Category 1 and Category 2 bending modes without additional horizontal re-aim.
3.1.1.2. Compliance with the requirements of paragraphs 6.2.5.1 and 6.3 of this Regulation, whichever applies, shall be
checked:
(a) In case of a category 2 bending mode: without additional horizontal re-aim;
(b) In case of a category 1 or a driving-beam bending mode: after having horizontally re-aimed the relevant
installation unit (by means of the goniometer for example) in the corresponding opposite direction.
3.1.2. When testing a category 1 or category 2 bending mode, for a turn radius of the vehicle other than specified in
paragraph 3.1.1 above: it shall be observed whether the light distribution is substantially uniform and no
undue glare occurs. If this cannot be confirmed the compliance with the requirement laid down in Table 1 of
Annex 3 to this Regulation shall be checked.ANNEX 10
DESCRIPTION FORMS
Maximum format: A4 (210 × 297 mm)
ADAPTIVE FRONT-LIGHTING SYSTEM DESCRIPTION FORM NO 1
AFS control signals relevant to the lighting functions, and modes of functions provided by the system
Function/mode(s) of, being influenced by the signal(1)
Passing-beam maeb-gnivirD
AFS Control Signal
C
ssalC
V
ssalC
E
ssalC
W
ssalC
L 49/80 EN Official Journal of the European Union 20.2.2019
Technical characteristics(2)
(use separate sheet, if needed)
None/default
V-Signal
E-Signal
W-Signal
T-Signal
Other Signals(3)
(1) Mark in the respective box(es) with a cross (X) the combination(s) which apply.
(2) To be indicated in terms of:
(a) Physical nature (electrical current/voltage, optical, mechanical, hydraulic, pneumatic, ...).
(b) Information type (continuous/analogous, binary, digitally coded, ...).
(c) Time dependent properties (time constant, resolution, ...).
(d) Signal status when the respective conditions according to paragraph 6.22.7.4 of Regulation No 48 are fulfilled.
(e) Signal status in case of failure (with reference to the system input).
(3) According to the applicants description; use separate sheet, if needed.
ADAPTIVE FRONT-LIGHTING SYSTEM DESCRIPTION FORM NO 2
Cut-off status, adjustment devices and adjustment procedures relevant to the lighting units
Cut-off status(2) Adjustment device
The lighting unit provides or con
tributes to one or more passing- vertical horizontal
Characteristics
beam cut-off(s),
Lighting unit & additional
No(1) provisions (if
and provisions
any)(5)
as defined in of paragraph linked to linked to
Individual Individual
Annex 8 of this 6.4.6 of this ‘master’ unit ‘master’ unit
(‘master’)(3)(6) (‘master’)(3)(6)
Regulation(3) Regulation No(4) No(4)
apply(3)
1 yes/no yes/no yes/no .. .. yes/no .. ..
2 yes/no yes/no yes/no .. .. yes/no .. ..
3 yes/no yes/no yes/no .. .. yes/no .. ..
4 yes/no yes/no yes/no .. .. yes/no .. ..
5 yes/no yes/no yes/no .. .. yes/no .. ..20.2.2019 EN Official Journal of the European Union L 49/81
Cut-off status(2) Adjustment device
The lighting unit provides or con
tributes to one or more passing- vertical horizontal
Characteristics
beam cut-off(s),
Lighting unit & additional
No(1) provisions (if
and provisions
any)(5)
as defined in of paragraph linked to linked to
Individual Individual
Annex 8 of this 6.4.6 of this ‘master’ unit ‘master’ unit
(‘master’)(3)(6) (‘master’)(3)(6)
Regulation(3) Regulation No(4) No(4)
apply(3)
6 yes/no yes/no yes/no .. .. yes/no .. ..
7 yes/no yes/no yes/no .. .. yes/no .. ..
(1) Designation of each individual lighting unit of the system as indicated in Annex 1 to this Regulation and as shown in the drawing according to
paragraph 2.2.1 of this Regulation; use separate sheet(s) if needed.
(2) Relevant to provisions of paragraph 6.22.6.1.2 of Regulation No 48.
(3) Strike out what does not apply.
(4) Indicate corresponding lighting unit(s) number(s), if applicable.
(5) Information such as e.g.: the order of adjustment of lighting units or assemblies of lighting units, any additional provisions for the adjustment pro
cess.
(6) The adjustment of a ‘master’ lighting unit may also adjust (an) other lighting unit(s).L 49/82 EN Official Journal of the European Union 20.2.2019
ANNEX 11
REQUIREMENTS FOR LED MODULES AND ADAPTATIVE FRONT-LIGHTING (AFS) INCLUDING LED
MODULES
1. GENERAL SPECIFICATIONS
1.1. Each LED module sample submitted shall conform to the relevant specifications of this Regulation when
tested with the supplied electronic light source control-gear(s), if any.
1.2. LED module(s) shall be so designed as to be and to remain in good working order when in normal use. They
shall moreover exhibit no fault in design or manufacture. A LED module shall be considered to have failed if
any one of its LEDs has failed.
1.3. LED module(s) shall be tamperproof.
1.4. The design of removable LED module(s) shall be such that:
1.4.1. When the LED module is removed and replaced by another module provided by the applicant and bearing
the same light source module identification code, the photometric specifications of the AFS shall be met;
1.4.2. LED modules with different light source module identification codes within the same lamp housing, shall not
be interchangeable.
2. MANUFACTURE
2.1. The LED(s) on the LED module shall be equipped with suitable fixation elements.
2.2. The fixation elements shall be strong and firmly secured to the LED(s) and the LED module.
3. TEST CONDITIONS
3.1. Application
3.1.1. All samples shall be tested as specified in paragraph 4. below.
3.1.2. The kind of light sources on a LED MODULE shall be light-emitting diodes (LED) as defined in Regulation No
48 paragraph 2.7.1 in particular with regard to the element of visible radiation. Other kinds of light sources
are not permitted.
3.2. Operating conditions
3.2.1. LED module operating conditions
All samples shall be tested under the conditions as specified in paragraph 2.5 of Annex 9. to this Regulation.
If not specified differently in this annex LED modules shall be tested inside the AFS as submitted by the
manufacturer.
3.2.2. Ambient temperature
For the measurement of electrical and photometric characteristics, the AFS shall be operated in a dry and still
atmosphere at an ambient temperature of 23 °C ± 5 °C.
3.3. Ageing
Upon the request of the applicant the LED module shall be operated for 15 hours and cooled down to
ambient temperature before starting the tests as specified in this Regulation.20.2.2019 EN Official Journal of the European Union L 49/83
4. SPECIFIC SPECIFICATIONS AND TESTS
4.1. Colour rendering
4.1.1. Red content
In addition to measurements as described in paragraph 7 of this Regulation:
The minimum red content of the light of a LED module or AFS incorporating LED module(s) tested at 50
V shall be such that:
78R0 nm
EðλÞ VðλÞ dðλÞ
e
k ¼λ ¼ 610 nm �0,05
red 78R0 nm
EðλÞ VðλÞ dðλÞ
e
λ ¼ 380 nm
Where:
E(λ) (unit: W) is the spectral distribution of the irradiance;
e
V(λ) (unit: 1) is the spectral luminous efficiency;
(λ) (unit: nm) is the wavelength.
This value shall be calculated using intervals of one nanometre.
4.2. UV-radiation
The UV-radiation of a low-UV-type LED module shall be such that:
40R0 nm
EðλÞ SðλÞ dðλÞ
e
k ¼ λ ¼ 250 nm � 10 − 5 W=lm
UV 78R0 nm
k EðλÞ VðλÞ dðλÞ
m e
λ ¼ 380 nm
Where:
S(λ) (unit: 1) is the spectral weighting function;
k = 683 lm/W is the maximum value of the luminous efficacy of radiation.
m
(For definitions of the other symbols see paragraph 4.1.1 above).
This value shall be calculated using intervals of one nanometre. The UV-radiation shall be weighted according
to the values as indicated in the Table UV below:
Table UV
Values according to ‘IRPA/INIRC Guidelines on limits of exposure to ultraviolet radiation’. Wavelengths (in na
nometres) chosen are representative; other values should be interpolated.
λ S(λ) λ S(λ) λ S(λ)
250 0,430 305 0,060 355 0,000 16
255 0,520 310 0,015 360 0,000 13
260 0,650 315 0,003 365 0,000 11L 49/84 EN Official Journal of the European Union 20.2.2019
λ S(λ) λ S(λ) λ S(λ)
265 0,810 320 0,001 370 0,000 09
270 1,000 325 0,000 50 375 0,000 077
275 0,960 330 0,000 41 380 0,000 064
280 0,880 335 0,000 34 385 0,000 053
285 0,770 340 0,000 28 390 0,000 044
290 0,640 345 0,000 24 395 0,000 036
295 0,540 350 0,000 20 400 0,000 030
300 0,300
4.3. Temperature stability
4.3.1. Illuminance
4.3.1.1. For each existing class of passing-beam and for the driving-beam, a photometric measurement shall be
carried out after one minute of operation of the respective lighting units and for the following test points:
Passing-beam: 25 RR
Driving-beam: HV
4.3.1.2. Operation of the lighting units mentioned in paragraph 4.3.1.1 above shall then be continued until
photometric stability has occurred; this condition is considered to be fulfilled if the variation of the
illuminance for the test points indicated in paragraph 4.3.1.1 above is less than 3 per cent within any
15 minutes period. After photometric stability has occurred, aiming for complete photometry shall be
performed and the photometric values at all required test points shall be determined.
4.3.1.3. The ratio between the photometric values measured after one minute of operation and those measured after
photometric stability has occurred shall be calculated for the test points indicated in paragraph 4.3.1.1 above.
This ratio shall then be applied to all other applicable test points to determine their photometric values after
one minute of operation.
4.3.1.4. The illuminance values determined after one minute of operation and after occurrence of photometric
stability shall comply with applicable photometric requirements.
4.3.2. Colour
The colour of the light emitted measured after one minute and measured after photometric stability has been
obtained, as described in paragraph 4.3.1.2 of this annex, shall both be within the required colour
boundaries.
5. THE MEASUREMENT OF THE OBJECTIVE LUMINOUS FLUX OF LED MODULE(S) PRODUCING THE CLASS C (BASIC)
PASSING-BEAM SHALL BE CARRIED OUT AS FOLLOWS:
5.1. The LED module(s) shall be in the configuration as described in the technical specification as defined in
paragraph 2.2.2 of this Regulation. Optical elements (secondary optics) shall be removed by the Technical
Service at the request of the applicant by the use of tools. This procedure and the conditions during the
measurements as described below shall be described in the test report.
5.2. One module of each type shall be submitted by the applicant with the light source control gear, if applicable,
and sufficient instructions.
Suitable thermal management (e.g. heat sink) may be provided, to simulate similar thermal conditions as in
the corresponding headlamp application.
Before the test the LED module shall be aged at least for seventy-two hours under the same conditions as in
the corresponding headlamp application.20.2.2019 EN Official Journal of the European Union L 49/85
In the case of use of an integrating sphere, the sphere shall have a minimum diameter of one meter, and at
least ten times the maximum dimension of the LED module, whichever is the largest. The flux measurements
can also be performed by integration using a goniophotometer. The prescriptions in CIE – Publication 84 –
1989, regarding the room temperature, positioning, etc., shall be taken into consideration.
The LED module shall be burned in for approximately one hour in the closed sphere or goniophotometer.
The flux shall be measured after stability has occurred, as explained in paragraph 4.3.1.2 of this annex.