Date: 2025-04-21 Category: Extra Ordinary State: Union Government Country: India

Gas meter Rules

Issued by Ministry of Consumer Affairs, Food and Public Distribution · Department of Consumer Affairs

Research with AI Agent Chat with Document Generate Summary Translate Helpful Share Add to Project Create Task

Executive Summary & Key Takeaways

**Report: Analysis of Amendment to the Legal Metrology General Rules, 2011 Concerning Gas Meters** **1. Executive Summary:** This report analyzes an amendment to the Legal Metrology General Rules, 2011, specifically concerning gas meters. The amendment, titled "Legal Metrology General Second Amendment Rules, 2025," introduces a new rule (27A) regarding the reverification schedule for various types of gas meters and introduces Part XI concerning gas meters. It defines reverification periods for volumetric meters, mass flow meters, base pressure and temperature conversion devices or recording devices and other meter devices and installations. The amendment also establishes comprehensive metrological and technical requirements, performance tests and metrological controls for gas meters. The core purpose is to ensure the continued accuracy and reliability of gas meters used in trade and commerce. **2. Introduction:** This report provides an informative analysis of the "Legal Metrology General Second Amendment Rules, 2025," an amendment to the Legal Metrology General Rules, 2011. The analysis is based solely on the provided policy text and aims to inform stakeholders about the key changes and their potential impact. **3. Policy Overview:** * This report analyzes an amendment to the Legal Metrology General Rules, 2011. * **Core Objective(s):** Based on the provided text, the amendment's core objectives include: * Establishing a specific reverification schedule for different types of gas meters (volumetric, mass flow, etc.). * Specifying metrological and technical requirements for gas meters based on any measurement technology or principle. * Defining terminology related to gas meters and their constituents. * Setting rated operating conditions, accuracy classes and maximum permissible errors (MPE) for gas meters. * Defining marking and inscription requirements for gas meters. * Providing requirements for software controlled gas meters. * Providing metrological controls and performance tests for gas meters. **4. Background and Rationale:** The amendment likely addresses the need for periodic verification of gas meters to account for wear and tear, environmental factors, and technological advancements. By setting specific reverification schedules, the amendment aims to ensure that gas meters maintain their accuracy over time, safeguarding the interests of consumers and ensuring fair trade practices. The introduction of Part XI establishes more detailed, technology-specific requirements for gas meters, suggesting a need to update existing regulations to cover a wider range of meter types and functionalities. **5. Key Provisions / Changes:** The key changes introduced by the amendment are: * **Insertion of Rule 27A: Special provision for reverification:** * **What is Changed:** Adds a new rule mandating specific reverification schedules for gas meters. * **New Provision:** The new rule establishes reverification periods for different types of gas meters, including volumetric meters (Diaphragm, Rotary Pressure body, Turbine, etc.), mass flow meters (NGV Dispenser Coriolis System, Thermal), and base pressure and temperature conversion devices (Chart Recorder, Mechanical type Rotary meter Volume Conversion modules Device, Electronic type Volume Conversion Device, Flow Computer, Transducer or Transmitter). The reverification periods vary depending on the type of meter and whether it's the initial or subsequent reverification. * **Effect of Change:** This change introduces a legally binding requirement for periodic reverification, ensuring the accuracy of gas meters over their operational life. It clarifies the frequency of reverification, which might not have been explicitly addressed or consistently applied in the original rules. * **Insertion of PART XI: GAS METERS:** * **What is Changed:** Adds a new part defining metrological and technical requirements for gas meters. * **New Provision:** This part outlines terminology, metrological characteristics, operating conditions, test conditions, and electronic equipment requirements. It establishes accuracy classes, maximum permissible errors (MPE), and requirements for construction, inscriptions, operating instructions, sealing, and testing suitability. Annexure I includes requirements for software-controlled gas meters. * **Effect of Change:** This addition provides comprehensive guidelines and standards for the manufacture, installation, and operation of gas meters, likely modernizing and strengthening the regulatory framework. **6. Target Audience and Stakeholders:** The primary target audience includes: * Manufacturers of gas meters * Suppliers and distributors of gas meters * Gas companies and utilities * Consumers of gas * Legal metrology authorities and testing laboratories **7. Implementation Aspects (Inferred):** * **Responsible Agency/Bodies:** The Department of Consumer Affairs, under the Ministry of Consumer Affairs, Food and Public Distribution, is responsible for implementing and enforcing these rules. * **Timelines/Procedures:** * The amendment comes into force on September 1, 2025. * Reverification must be carried out according to the timelines specified in Tables 1, 2, 3 and 4 of the amended rule 27A. * Meter inspections are mandated at the operational location during reverification. * Detailed test procedures and programs will be necessary to verify compliance with the new metrological and technical requirements in Part XI. **8. Expected Outcomes / Impact of Changes:** The expected outcomes of these changes include: * Improved accuracy and reliability of gas meters in use. * Enhanced consumer protection through fair and transparent measurement of gas consumption. * Standardized testing and verification procedures for gas meters. * Increased compliance with legal metrology requirements by manufacturers and users. * Modernization of the legal metrology framework for gas meters, accommodating new technologies and measurement principles. * Assurance of the integrity of stored, transmitted, and indicated data by software control. **9. Conclusion:** The "Legal Metrology General Second Amendment Rules, 2025" represents a significant update to the regulatory framework for gas meters in India. By introducing mandatory reverification schedules and comprehensive technical standards, the amendment seeks to enhance the accuracy, reliability, and fairness of gas measurement. The changes are likely to have a broad impact on manufacturers, suppliers, gas companies, and consumers, ultimately contributing to a more efficient and transparent energy market. The amendment's emphasis on software control also reflects the increasing role of technology in modern metering systems.

Key Entities Referenced

Legal Metrology Act 2009: Act under which the rules are being exercised. section 52: Section of the Legal Metrology Act 2009, providing the powers to make rules. Legal Metrology General Rules, 2011: The rules being amended. Legal Metrology General Second Amendment Rules, 2025: Title of the amendment rules. 1st day of September, 2025: Date when the new rules come into force. PART XI GAS METERS: Part of the Eighth Schedule being inserted related to gas meters. Qmax: Maximum flow rate. Qmin: Minimum flow rate. Qt: Transitional flow rate. MPE: Maximum Permissible Error. WME: Weighted Mean Error. 10 Hz 150 Hz, 1.6 ms2, 0.05 m2s3: Vibration limits. 3dBoctave: Another specification related to vibration. 40C, 25C, 10C, 00C: Low Ambient Temperature Range. 5C: Low Ambient Temperature Range. 30C,40C,55C, 650C: High Ambient Temperature Range. 70C: High Ambient Temperature Range. 86 kPa 106 kPa: Atmospheric pressure range. 3 GHz: Upper frequency limit for radiated radio frequency test. 10 Vm: Electric field strength used in immunity tests for electromagnetic fields. 80MHz: Upper frequency limit for conducted common mode currents generated by radio frequency electromagnetic fields. 6 kV: Electrostatic discharge voltage for contact discharge test. 8 kV: Electrostatic discharge voltage for air discharge test. 5 kHz: Repetition rate for bursts transients on signal, data and control lines tests. 0.5 kV: Surge amplitude on signal, data and control lines. 1.0 kV: Surge amplitude for line to ground. 2.0 kV: Surge amplitude on AC and DC Mains for line to ground 2 kV: Amplitude for Bursts transients on AC and DC mains. 50 Hz 60 Hz: AC mains frequency. Ministry of Consumer Affairs, Food and Public Distribution Department of Consumer Affairs: The ministry and department responsible for this notification. G.S.R. 242E: Notification number. V: volume m: mass SI units: International System of Units I: mechanical sealing II: electronic sealing U 10 nom: lower voltage limit. U 15 nom: upper voltage limit. f 2 nom: upper frequency limit. f 2 nom: lower frequency limit. III: flow disturbance D L.3300499: Registration number. NEW DELHI, MONDAY, APRIL 21, 2025: Place and date of publication. VAISAKHA 01, 1947: Corresponding date in the Indian national calendar. chart recorder: devices used for recordng data. flow computer: device used for measurement. Massflow meters: types of meters. NGV: types of meters.
Official Source Record View Original Source →
See Full Document Text
रजिस्ट्री स.ं डी.एल.- 33004/99 REGD. No. D. L.-33004/99 xxxGIDHxxx ससीी..जजीी..--डडीी..एएललxx..x--GअअID..--E22x55xx00 4422002255--226622665522 CCGG--DDLL--EE--2255004422002255--226622665522 असाधारण EXTRAORDINARY भाग II—खण् ड 3—उप-खण्ड (i) PART II—Section 3—Sub-section (i) प्राजधकार स ेप्रकाजित PUBLISHED BY AUTHORITY स.ं 203] िई दिल्ली, सोमर्ार, अप्रैल 21, 2025/र्िै ाख 01, 1947 No. 203] NEW DELHI, MONDAY, APRIL 21, 2025/VAISAKHA 01, 1947 उपभोक्त ा मामल,े खाद्य और सार्िव जिक जर्तरण मत्रं ालय (उपभोक्त ा मामल े जर्भाग) अजधसचू िा िई दिल् ली, 21 अप्रैल 2025 सा.का.जि. 242.—केंद्रीय सरकार, जर्जधक मापजर्ज्ञाि अजधजियम, 2009 (2010 का ।) की धारा 52 की उपधारा (2) के खंड (ग), (च), (झ) और (ध) के साथ पठित उपधारा (1) द्वारा प्रित् त िजियों का प्रयोग करत े हुए जर्जधक माप जर्ज्ञाि (साधारण) जियम, 2011 म ेंऔर संिोधि करिे के जलए,जिम्नजलजखत जियम बिाती ह,ै अथावत:् - 1. सजं िप्त िाम और प्रारंभ.– (1) इि जियमों का संजिप्त िाम जर्जधक मापजर्ज्ञाि (साधारण) िसू रा संिोधि जियम, 2025 ह।ै (2) य ेजसतम्बर, 2025 के पहले दिि से प्रभार्ी होंगें। 2. जर्जधक माप जर्ज्ञाि (साधारण) जियम, 2011 (जिसे इसके पश्चात उि जियम कहा िाएगा) में जियम 27 के पश्चात जिम्नजलजखत जियम अंतर्र्वष्ट दकया िाएगा, अथावत:- “27क. पिु ः सत्यापि के जलए जर्िेष उपबंध - जिम्नजलजखत मीटरों का पुिः सत्यापि िीचे िी गई सारणी में जिर्िवष्ट अर्जध के पूरा होि े पर दकया िाएगा, अथावत:- (क) र्ॉल्यूमेठरक मीटर के जलए,- 2642 GI/2025 (1)2 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] सारणी 1. क्रम स.ं प्रकार उप-प्रकार प्रारंजभक पिु ः सत्यापि पश्चातर्ती पिु ः अर्जध सत्यापि अर्जध (1) (2) (3) (4) (5) 1. डायाफ्राम मीटर 7 र्ष व 5 र्ष व 2. रोटरी प्रेिर बॉडी 20 र्षव 17 र्षव 3. टरबाइि सभी प्रकार 6 र्ष व 4 र्ष व 4. जिद्र प्लेट, दिटटंग, ट्यूब और फ्लो कंडीििर 6 र्ष व 4 र्ष व 5. अल्रासोजिक अल्रासोजिक गैस मीटर 6 र्ष व 4 र्ष व 6. द्रर्ीय-िोलि सभी प्रकार 6 र्ष व 4 र्ष व 7. भंर्र सभी प्रकार 6 र्ष व 4 र्ष व 8. िंकु के आकार का अंतर सभी प्रकार िबार् 6 र्ष व 4 र्ष व (ख) मास-फ्लो मीटर के जलए,- सारणी 2. क्रम स.ं प्रकार उप-प्रकार प्रारंजभक पिु ः सत्यापि पश्चातर्ती पिु ः अर्जध सत्यापि अर्जध (1) (2) (3) (4) (5) 9. कोठरओजलस एििीर्ी जडस्ट्पेंसर जसस्ट्टम 1 र्षव 1 र्षव अन्य सभी प्रकार 6 र्ष व 4 र्ष व 10. थमवल सभी प्रकार 6 र्ष व 4 र्ष व (ग) आधार िबार् और तापमाि रूपांतरण उपकरणों या ठरकॉर्डगिं उपकरणों के जलए,- सारणी 3 क्रम स.ं प्रकार उप-प्रकार प्रारंजभक पिु ः सत्यापि पश्चातर्ती पिु ः अर्जध सत्यापि अर्जध (1) (2) (3) (4) (5) 11. चाटव ठरकॉडवर सभी प्रकार होस्ट्ट मीटर के समाि होस्ट्ट मीटर के समाि 12. मैकेजिकल-टाइप रोटरी मीटर मॉड्यूल 7 र्ष व 5 र्ष व र्ॉल्यूम कन्र्िवि जडर्ाइस[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 3 सभी अन्य प्रकार 13. इलेक्रॉजिक प्रकार का सभी प्रकार 7 र्ष व 5 र्ष व र्ॉल्यूम कंर्िेंस उपकरण 14. फ्लो कंप्यूटर सभी प्रकार 6 र्ष व 4 र्षव 15. रांसड्यूसर या रांसमीटर सभी प्रकार 7 र्ष व 5 र्षव (घ) अन्य मीटरों, उपकरणों और सस्ट्ं थापिाओं के जलए,- मीटर उपकरण और संस्ट्थापिाएं िो उपरोि क्रमांक 1 से 15 म ें िाजमल िहीं ह।ैं सारणी 4. क्रम स.ं प्रकार उप-प्रकार प्रारंजभक पिु ः सत्यापि पश्चातर्ती पिु ः अर्जध सत्यापि अर्जध (1) (2) (3) (4) (5) 16. गैस जर्श्लेषक या सभी प्रकार 1 र्ष व 1 र्ष व क्रोमैटोग्राि 17. ऊिाव घित्र् सभी प्रकार 1 र्ष व 1 र्ष व 18. सापेि घित्र् सभी प्रकार 1 र्ष व 1 र्ष व 19. प्रर्ाह कंडीििर जिदद्रत प्लेट होस्ट्ट मीटर के समाि होस्ट्ट मीटर के समाि ट्यूब बंडल (सीधा होस्ट्ट मीटर के समाि होस्ट्ट मीटर के समाि करिे र्ाली पंखुज़ियााँ) 20. सुधार उपकरण सभी प्रकार (2) होस्ट्ट मीटर के समाि होस्ट्ट मीटर के समाि 21. ठटकट प्प्रंटर सभी प्रकार होस्ट्ट मीटर के समाि होस्ट्ट मीटर के समाि 22. टेलीमीटटरंग जडर्ाइस सभी प्रकार होस्ट्ट मीटर के समाि होस्ट्ट मीटर के समाि या जसस्ट्टम 23. मीटटरंग इंस्ट्टॉलेिि िबार् कारक मापि होस्ट्ट मीटर के समाि होस्ट्ट मीटर के समाि (पीएिएम) सभी अन्य प्रकार होस्ट्ट मीटर के समाि होस्ट्ट मीटर के समाि ठटप्पण (1): पिु ः सत्यापि अर्जध ऊपर बताई गई अर्जध के अिुसार होगी तथा मीटर के पिु ः सत्यापि के समय उपकरणों का उिके पठरचालि स्ट्थाि पर जिरीिण दकया िाएगा। ठटप्पण (2): "रैजखकीकरण" फंक्िि को या तो इलेक्रॉजिक र्ॉल्यूमेठरक मीटर या फ्लो कंप्यूटर के सर्कवट जडजाइि म ें िाजमल दकया िा सकता ह,ै या एक अलग सुधार उपकरण म ेंिाजमल दकया िा सकता ह।ै ठटप्पण (3): अन्य उपकरणों (िैसे इलेक्रॉजिक प्रकार के र्ॉल्यूम रूपांतरण उपकरण, फ्लो कंप्यूटर और रांसड्यूसर या रांसमीटर) का सत्यापि या पिु ः सत्यापि दकया िाएगा िो माप को प्रभाजर्त कर सकते ह।ैं4 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] 3. उि जियमों की आिर्ीं अिुसूची में, भाग X के पश्चात् जिम्नजलजखत भाग अंतर्र्वष्ट दकया िाएगा, अथावत:- “भाग XI गैस मीटर भाग 1 मेरोलॉजिकल और तकिीकी अपेिाएं 1. ित्रे .– (1) यह भाग दकसी भी माप तकिीक या जसद्ांत के आधार पर गैस मीटर पर लाग ू होता ह ै जिसका उपयोग ऑपरेटटंग पठरजस्ट्थजतयों में मीटर स े गुिरिे र्ाली गैस की मात्रा को मापिे के जलए दकया िाता ह।ै गसै की मात्रा को आयति या द्रव्यमाि की इकाइयों म ेंव्यि दकया िा सकता ह।ै (2) यह भाग गैस मीटरों पर लागू होता ह ै जििका उद्देश्य गैसीय ईंधि या अन्य गैसों की मात्रा को मापिा ह।ै यह सीएििी जडस्ट्पेंसर म ें उपयोग की िािे र्ाली तरलीकृत अर्स्ट्था, बहु-चरण, भाप और संपीज़ित प्राकृजतक गैस (सीएििी) म ें गैसों के जलए उपयोग दकए िाि े र्ाले मीटर को कर्र िहीं करता ह।ै (3) यह भाग अंतर्िवर्मवत सुधार उपकरणों, आतं ठरक तापमाि िजतपूर्तव उपकरणों पर लागू होता ह ै तथा इसम ें गैस मीटर स े िु़िा कोई भी अन्य इलेक्रॉजिक उपकरण िाजमल होता ह।ै 2. िब्िार्ली.– 2(1) गसै मीटर और उसके घटक,– (i) गैस – मीटर,– प्रर्ाह सेंसर से गुिरि े र्ाली गसै की मात्रा को मापिे, याि रखिे और प्रिर्िवत करि े र्ाला उपकरण; (ii) मापि,– मापी िािे र्ाली इजछित मात्रा; (iii) सेंसर,– मापिे की प्रणाली का र्ह तत्र् िो मापी िािे र्ाली मात्रा ले िािे र्ाली दकसी रीजत, माध्यम या पिाथ व से सीध े प्रभाजर्त होता ह;ै (iv) मापिे र्ाला रांसड्यूसर,– माप में उपयोग दकया िािे र्ाला उपकरण, िो इिपुट मात्रा के साथ एक जिर्िष्टव संबंध रखते हुए आउटपुट मात्रा प्रिाि करता ह;ै (v) कैलकुलेटर,– गैस मीटर का र्ह भाग िो मापिे र्ाल े रांसड्यूसर और संबंजधत माप उपकरणों स े आउटपटु जसग्नल प्राप्त करता है, उन्ह ें पठरर्र्तवत करता ह ै और पठरणामों को मेमोरी म ें तब तक सग्रं हीत करता ह ै िब तक उिका उपयोग िहीं दकया िाता ह।ै इसके अजतठरि, कैलकुलेटर सहायक उपकरणों के साथ िोिों तरीकों से संचार करिे म ेंसिम हो सकता है; (vi) संकेत या जडस्ट्प्ल े करि े र्ाला उपकरण,– गैस मीटर का र्ह भाग िो जिरंतर या मांग पर माप पठरणाम प्रिर्िवत करता ह;ै ठटप्पण: एक मुद्रण उपकरण, िो माप के अंत म ेंएक संकेत प्रिाि करता ह,ै एक संकेत उपकरण िहीं ह।ै[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 5 (vii) सुधार उपकरण,– फंक्िि म ें ज्ञात त्रुठटयों के सधु ार के जलए अजभप्रेत उपकरण, उिाहरण के जलए प्रर्ाह िर, रेिॉल््स संख्या (र्क्र रैजखकीकरण), घित्र्, िबार् या तापमाि या इिके संयोिि म;ें (viii) सहायक उपकरण,– एक जर्िेष कायव करिे र्ाला उपकरण, िो सीधे माप पठरणामों को जर्स्ट्तृत करिे, प्रसाठरत करिे या प्रिर्ितव करि े के जलए होता ह;ै मुख्य सहायक उपकरण ह,ैं – (क) िोहरािे र्ाला संकेत उपकरण; (ख) मुद्रण उपकरण; (ग) मेमोरी जडर्ाइस; और (घ) संचार उपकरण। ठटप्पण 1: एक सहायक उपकरण को मेरोलॉजिकल जियंत्रण के अधीि होिा अपेजित िहीं ह।ै ठटप्पण 2: गैस मीटर में एक सहायक उपकरण आज्ञापक दकया िा सकता ह।ै (ix) संबंजधत मापि उपकरण,– सुधार करि े के उद्देश्य स ेकुि गसै गुणों को मापि े के जलए कैलकुलेटर या सुधार उपकरण से ि़िु ा उपकरण; (x) परीिणाधीि उपकरण (ईक्यूपमेंट अडं र टेस्ट्ट),– गैस मीटर या संबंजधत उपकरणों या िोिों का र्ह भाग िो दकसी परीिण के संपकव म ेंआता है; (xi) गैस मीटर र्ग,व – जर्जभन्न आकारों या जर्जभन्न प्रर्ाह िरों या उिके संयोिि के गैस मीटरों का समूह, जिसमें सभी मीटरों म ें जिम्नजलजखत जर्िेषताएं होंगी; अथावत:- • समाि जर्जिमावता; • मापिे र्ाल ेभाग की ज्याजमतीय समािता; • एक ही मीटटरंग जसद्ांत; • लगभग एक ही अिुपात क्यूमक्ै स/क्यूजमि और क्यूमैक्स/क्यूटी; • एक ही सटीकता र्ग;व • प्रत्येक मीटर आकार के जलए एक ही इलेक्रॉजिक उपकरण [परै ा 2 के उप- परै ा (5) का खडं (ii) म ें जर्जिर्िवष्टािुसार] और उि घटकों के जलए एक ही मेरोलॉजिकल सॉफ़्टर्ेयर रूटीि (यदि लाग ू हो) का उपयोग करिा िो मीटर के प्रििवि के जलए महत्र्पूण व हैं; • जडजाइि और घटक असेंबली का एक समाि मािक; और • उि घटकों के जलए एक ही सामग्री िो मीटर के प्रििवि के जलए महत्र्पूणव हैं।6 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] 2 मेरोलॉजिकल जर्िेषताएं,- (i) गैस की मात्रा,– समय के साथ गैस मीटर स े गजु रिे र्ाल े प्रर्ाह को एकीकृत करके प्राप्त गैस की कुल मात्रा, जिसे आयति ‘V’ या द्रव्यमाि ‘m’ के रूप म ें व्यि दकया िाता है, समय की परर्ाह दकए जबिा। गैस की मात्रा संबंजधत माप ह ै [परै ा 2 का उप-पैरा (1) का खंड (ii) में यथा पठरभाजषत]; (ii) ििावया गया मल्ू य (मात्रा का),– दकसी मात्रा का माि Y, िैसा दक मीटर द्वारा ििावया गया है; i (iii) गैस मीटर का चक्रीय आयति (केर्ल धिात्मक जर्स्ट्थापि गैस मीटर),– मीटर के अंिर गजतिील भागों के एक पूण व चक्कर (कायव चक्र) के अिरूु प गैस का आयति; (iv) त्रुठट,– मापी गई मात्रा माि घटार् संिभव मात्रा माि; (v) भाठरत माध्य त्रुठट (डब्लूएमई),– इस जियम के अंतगवत भाठरत माध्य त्रुठट (डब्लूएमई) को इस प्रकार पठरभाजषत दकया गया ह:ै WME = with k = for Q ≤ 0.7 Q i i max k = 1.4- for 0.7 Q ≤ Q ≤ Q i max i max िहााँ: k = प्रर्ाह िर Q पर भार कारक; i i E = प्रर्ाह िर Q पर त्रुठट। i i (vi) आंतठरक त्रुठट,– संिभव जस्ट्थजतयों के अधीि जिधाठव रत त्रुठट; (vii) िोष,– संकेत की त्रुठट और माप उपकरण की आंतठरक त्रुठट के बीच का अंतर; ठटप्पण 1: व्यर्हार म ेंयह परीिण के िौराि या उसके बाि िखे ी गई मीटर की त्रुठट और संिभव जस्ट्थजतयों के अधीि दकए गए इस परीिण से पहल े मीटर की त्रुठट के बीच का अंतर ह।ै ठटप्पण 2: "मापि उपकरण" की व्याख्या "गैस मीटर" के रूप म ेंकी िािी चाजहए। (viii) अजधकतम स्ट्र्ीकायव त्रुठट (एमपीई),– दकसी ज्ञात संिभव मात्रा माि के संबंध में माप त्रुठट का चरम माि, दकसी दिए गए माप, माप उपकरण या माप प्रणाली के जलए जर्जििेिों या जर्जियमों द्वारा अिुमत;[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 7 (ix) सटीकता श्रणे ी,– माप उपकरणों या माप प्रणाजलयों की श्रेणी िो जिर्िष्टव माप सबं ंधी अपेिाओं को पूरा करता है, जिसका उद्देश्य माप त्रुठटयों या उपकरण अजिजश्चतताओं को जिर्िवष्ट पठरचालि जस्ट्थजतयों के अधीि जिर्िष्टव सीमाओं के भीतर रखिा है; (x) स्ट्थाजयत्र्,– यह दकसी मापक उपकरण की उपयोग की अर्जध में अपिी प्रििवि जर्िेषताओं को बिाए रखिे की िमता को संिर्भवत करता ह;ै (xi) माप पठरिुद्ता,– जिर्िवष्ट जस्ट्थजतयों के अधीि समाि या समाि र्स्ट्तओंु पर िोहराए गए मापों द्वारा प्राप्त संकेतों या मापी गई मात्रा मूल्यों के बीच समझौते की जिकटता; (xii) पुिरार्ृजि,– यह माप की पिु रार्ृजि जस्ट्थजतयों के एक सेट के अधीि माप पठरिुद्ता को संिर्भवत करता है; (xiii) त्रुठट की पुिरार्ृजि,– यह संिभव जस्ट्थजतयों के अधीि पिु रार्ृजि और माप के बीच प्रर्ाह िर में पठरर्तवि ि करि े को संिर्भवत करता है; (xiv) पुिरुत्पािकता,– यह माप की पिु रुत्पािकता की जस्ट्थजत के अधीि माप सटीकता को संिर्भवत करता ह;ै (xv) त्रुठट की पुिरुत्पािकता,– यह संिभव जस्ट्थजतयों के अधीि पिु रुत्पािकता और माप के बीच प्रर्ाह िर को बिलि े को संिेय; (xvi) संचालि की जस्ट्थजत,– गैस की जस्ट्थजत (तापमाि, िबार् और गैस संरचिा) जिस पर गैस की मात्रा मापी िाती ह ै (xvii) रेटेड पठरचालि जस्ट्थजतयााँ,– मापि और प्रभार् मात्राओं के मािों की सीमा िेि े र्ाली उपयोग की जस्ट्थजतयााँ, जिसके जलए गैस मीटर की त्रुठटयों को अजधकतम स्ट्र्ीकायव त्रुठट की सीमा के भीतर होिा अपेजित ह;ै (xviii) अपेजित जस्ट्थजतयााँ,– गैस मीटर के प्रििवि का परीिण करि े या माप के पठरणामों की अंतर-तलु िा के जलए जिधावठरत संिभव मािों या प्रभार् मात्राओं की संिभव सीमाओं का सेट; (xix) आधार जस्ट्थजतयााँ,– र्े जस्ट्थजतयााँ जििम ेंगैस की मापी गई मात्रा को पठरर्र्तवत दकया िाता ह ै(उिाहरण: आधार तापमाि और आधार िबार्)।8 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] ठटप्पण: पठरचालि और आधार जस्ट्थजतया ं केर्ल मापी िािे र्ाली या संकेजतत की िाि े र्ाली गैस की मात्रा स े संबंजधत ह ैं और इन्ह ें "रेटेड पठरचालि जस्ट्थजतयों" और "संिभ व जस्ट्थजतयों" के साथ भ्रजमत िहीं दकया िािा चाजहए, िो प्रभार् मात्राओं को संिर्भवत करत े ह।ैं (xx) परीिण तत्र् (संकेतक उपकरण का),– मापी गई गैस मात्रा का सटीक र्ाचि करिे म ेंसिम उपकरण; (xxi) संकल्प (जडस्ट्प्ल े उपकरण का),– प्रिर्िवत संकेतों के बीच सबसे िोटा अंतर जिसे साथवक रूप स ेपहचािा िा सकता है। ठटप्पण: जडजिटल उपकरण के जलए, यह संकेत म ें पठरर्तवि ह ै िब सबसे कम महत्र्पूणव अकं एक किम से बिलता ह।ै एिालॉग जडर्ाइस के जलए, यह बाि के स्ट्केल जचह्िों के बीच का आधा अंतर ह।ै (xxii) इन्स्ट्ूमेंटल बहार्,– मापि यंत्र के माप संबंधी गुणों में पठरर्तवि के कारण संकेत में समय के साथ जिरंतर या र्ृजद्िील पठरर्तवि (3) पठरचालि जस्ट्थजतया,ाँ - गैस की जस्ट्थजतयााँ (तापमाि, िबार् और गैस संरचिा) जिि पर गैस की मात्रा मापी िाती ह;ै (i) प्रर्ाह िर (क्य)ू ,– गैस मीटर स े गुिरि े र्ाली गसै की र्ास्ट्तजर्क मात्रा और इस मात्रा को गैस मीटर से गिु रि े म ें लगि े र्ाल े समय का भागिल; (ii) अजधकतम प्रर्ाह िर (क्यू ),– मेक्स उच्चतम प्रर्ाह िर जिस पर गसै मीटर को अपिी अजधकतम अिुमेय त्रुठट की सीमाओं के भीतर काम करिा अपेजित है, िबदक इसे इसकी रेटेड पठरचालि जस्ट्थजतयों के भीतर संचाजलत दकया िा रहा ह;ै (iii) न्यिू तम प्रर्ाह िर (क्यू ),– जमि न्यूितम प्रर्ाह िर जिस पर गसै मीटर को अपिी अजधकतम अिुमेय त्रुठट की सीमाओं के भीतर काम करिा अपेजित है, िबदक इसे इसकी रेटेड पठरचालि जस्ट्थजतयों के भीतर संचाजलत दकया िा रहा ह;ै (iv) संक्रमणकालीि प्रर्ाह िर (क्यू ),– टी र्ह िर िो अजधकतम प्रर्ाह िर क्यू और न्यिू तम प्रर्ाह िर क्यूजमि के बीच होती ह ै िो प्रर्ाह िर सीमा को िो िेत्रों, मेक्स "ऊपरी िेत्र" और "जिचला िेत्र" म ेंजर्भाजित करती ह,ै जििम ेंसे प्रत्येक की अपिी अजधकतम अिुमेय त्रुठट होती ह;ै (v) काय वतापमाि (टी ),– डब्ल्यू गैस मीटर पर मापा िाि े र्ाला गैस का तापमाि; (vi) न्यूितम कायव तापमाि (t ) और अजधकतम कायव तापमाि (t ),– min max न्यूितम और अजधकतम गैस तापमाि जिसे एक गैस मीटर अपिी जिधावठरत पठरचालि जस्ट्थजतयों के भीतर, अपि े मेरोलॉजिकल प्रििवि म ेंअस्ट्र्ीकायव जगरार्ट के जबिा झले सकता है; (vii) जिर्िवष्ट तापमाि (t ),– sp[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 9 अंतर्िवजहत रूपांतरण उपकरणों र्ाले गैस मीटरों के जलए औसत तापमाि, लाग ू पठरचालि तापमाि सीमा के जिधावरण के जलए संिभव के रूप में उपयोग दकया िाता ह;ै ठटप्पण: t और गैस तापमाि के बीच का अंतर अजधकतम सभं ाजर्त त्रुठट के मूल्य पर प्रभार् डालता ह।ै sp (viii) कायव िबार् (p ),– w गैस मीटर पर मापी िाि े र्ाली गैस का िबार्; (ix) न्यूितम कायव िबार् (p ) और अजधकतम कायव िबार् (p ),– min max न्यूितम और अजधकतम आंतठरक िबार् जिसे गैस मीटर अपिी जिधावठरत पठरचालि जस्ट्थजतयों के भीतर, अपि े मेरोलॉजिकल प्रििवि म ेंजगरार्ट के जबिा झेल सकता ह ै (x) स्ट्थैजतक िबार् हाजि या िबार् अंतर(Δp),– गैस प्रर्ाजहत होि े के िौराि गैस मीटर के इिलेट और आउटलेट पर िबार्ों के बीच अंतर; (xi) कायव घित्र्, (ρw),– गैस मीटर के माध्यम से प्रर्ाजहत गैस का घित्र्, ρ और t के अिरूु प। w w (4) परीिण ित,ें – (i) प्रभार् मात्रा,– र्ह मात्रा िो प्रत्यि माप में, र्ास्ट्तर् में मापी गई मात्रा को प्रभाजर्त िहीं करती ह,ै लेदकि िो संकेत और माप पठरणाम के बीच के संबंध को प्रभाजर्त करती ह;ै (ii) बाधा,– प्रभार् मात्रा जिसका माि इस भाग में जिर्िवष्ट सीमाओं के भीतर है, लदे कि गैस मीटर की जिर्िवष्ट रेटेड पठरचालि जस्ट्थजतयों के बाहर ह;ै ठटप्पण: एक प्रभार् मात्रा एक बाधा ह ैयदि उस प्रभार् मात्रा के जलए रेटेड पठरचालि जस्ट्थजतयााँ जिर्िवष्ट िहीं ह।ैं (iii) ओर्रलोड जस्ट्थजतया,ाँ – रेटेड पठरचालि जस्ट्थजतयों (प्रर्ाह िर, तापमाि, िबार्, आद्रवता और जर्द्युत चुम्बकीय हस्ट्तिपे सजहत) के बाहर की जस्ट्थजतयााँ जिन्ह ेंगैस मीटर को अपि ेप्रिििव म ेंजगरार्ट के जबिा झेलिा अपेजित ह।ै (iv) परीिण,– परीिण के अधीि उपकरण (ईदिपमेंट अडं र टेस्ट्ट) की कुि अपेिाओं के साथ अिुपालि को सत्याजपत करि े के जलए संचालि की श्रृंखला; (v) परीिण प्रदक्रया,– परीिण संचालि का जर्स्ट्तृत जर्र्रण;10 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (vi) परीिण कायवक्रम,– दकसी जर्िेष प्रकार के उपकरण के जलए परीिणों की श्रृंखला का जर्र्रण; (vii) प्रिििव परीिण,– परीिण जिसका आिय यह सत्याजपत करिा ह ै दक परीिण के अंतगवत उपकरण (ईदिपमेंट अडं र टेस्ट्ट) अपिे इजछित कायों को पूरा करिे म ेंसिम ह ैया िहीं। (5) इलेक्रॉजिक उपकरण,– (i) इलेक्रॉजिक गैस मीटर,- इलेक्रॉजिक उपकरणों से सुसजित गैस मीटर। ठटप्पण: इस भाग के प्रयोििों के जलए सहायक उपकरण, िहााँ तक यह मेरोलॉजिकल जियंत्रण के अधीि ह,ै गैस मीटर का भाग मािा िाता ह,ै िब तक दक सहायक उपकरण को अलग से अिुमोदित और सत्याजपत िहीं दकया िाता ह।ै (ii) इलेक्रॉजिक उपकरण,– इलेक्रॉजिक उप-असेंबली का उपयोग करि े र्ाला और एक जर्जिष्ट काय व जिष्पादित करि े र्ाला उपकरण। इलेक्रॉजिक उपकरणों को साधारणतया पर अलग-अलग इकाइयों के रूप में जिर्मवत दकया िाता ह ै और स्ट्र्तंत्र रूप स े परीिण दकए िािे में सिम होते ह;ैं (iii) इलेक्रॉजिक घटक,– इलेक्रॉजिक उपकरण में सबसे िोटी भौजतक इकाई जिसका उपयोग दकसी माध्यम या र्ैक्यूम के माध्यम से इलेक्रॉिों और/या उिके संबंजधत िेत्रों को प्रभाजर्त करि े के जलए दकया िाता ह।ै 3. माप की इकाइया.ाँ – (1) माप इकाइयााँ,– सभी मात्राएाँ SI इकाइयों में व्यि की िाएगाँ ी। 4. मरे ोलॉजिकल अपिे ाएं.– (1) रेटेड पठरचालि ित,ें– सारणी क. गसै मीटर के जलए जिधाठव रत पठरचालि जस्ट्थजतया ंजिम्नािसु ार होंगी: (1) (2) (3) (क) पठरर्ेि का तापमाि (चिु ी गई तापमाि जिम्न –40°स,े –25°स,े –10°से, 00से और +5°से (1) सीमा कम से कम 50 K को कर्र करेगी) उच्च +30°स,े +40°स,े +55°से, 650से और +70°स े(1) (ख) पठरर्ेि सापेि आद्रवता जर्जिमावता द्वारा जिर्िवष्ट; कम स ेकम 93% तक (ग) र्ायुमंडलीय िबार् जर्जिमावता द्वारा जिर्िवष्ट; कम स ेकम 86 kPa – 106 kPa को कर्र करिा (घ) से कम कंपि 10 Hz – 150 Hz, 1.6 ms-2, 0.05 m2s-3[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 11 (ङ) डीसी मेि र्ोल्टेि (3) -3dB/ऑक्टेर् (च) एसी मेि र्ोल्टेि (3) जर्जिमावता द्वारा जिर्िवष्ट (ि) एसी मेि आर्ृजि (3) U – 15% से U + 10% nom nom (ि) प्रर्ाह िर सीमा f – 2% स े f + 2% nom nom (झ) गैसों का प्रकार Q से Q समार्ेिी min max (ञ) कायव िबार् सीमा: प्राकृजतक गैसों, औद्योजगक गैसों या सुपरदक्रठटकल गैसों का पठरर्ार; जर्जिमावता द्वारा जिर्िष्टव दकया िािा ह ै(2), (1) िेि की जर्जभन्न िलर्ायु पठरजस्ट्थजतयों के आधार पर तापमाि के जर्जभन्न मािों की अिुमजत ह।ै (2) सुपरदक्रठटकल से तात्पयव उस जस्ट्थजत से ह ैिहा ाँद्रर् की गैसीय और द्रर्ीभूत अर्स्ट्था के बीच कोई अतं र िहीं होता है (3) यदि लाग ूहो (2) Q , Q और Q के माि,– max t min गैस मीटर की प्रर्ाह िर जर्िेषताओं को Q , Q और Q के मािों द्वारा पठरभाजषत दकया िाएगा। उिके अिपु ात और max t min संबंध सारणी 1 म ेंबताई गई सीमाओं के भीतर होंग:े सारणी 1. प्रर्ाह िर जर्िेषताएाँ Q / Q Q / Q max min max t (1) (2) ≥ 50 ≥ 10 ≥ 5 and <50 ≥ 5 (3) सटीकता र्गव और अजधकतम स्ट्र्ीकायव त्रुठटयााँ (एमपीई),– (i) साधारण,– गैस मीटर को इस तरह से जडजाइि और जिर्मवत दकया िाएगा दक इसकी त्रुठटयााँ रेटेड ऑपरेटटंग जस्ट्थजतयों के अधीि लाग ू एमपीई से अजधक ि हों; (ii) सटीकता र्ग,व – गैस मीटर को तीि सटीकता र्गों 0.5, 1 और 1.5 में जर्भाजित दकया िा सकता ह।ै गैस मीटर को इिम ें से दकसी एक र्ग व में इसकी सटीकता के अिुसार र्गीकृत दकया िाएगा। एमपीई का माि िीच े सारणी 2 म ें जर्जिर्िवष्टािुसार लाग ू सटीकता र्गव पर जिभवर करता ह;ै (iii) ज्ञात त्रुठटयों के जलए सुधार,– गैस मीटर को एक सुधार उपकरण से सुसजित दकया िा सकता है, जिसका आिय त्रुठटयों को िून्य माि के जितिा संभर् हो सके उतिा कम करिा ह।ै इस तरह के सुधार उपकरण का उपयोग पूर्व-अिुमाजित बहार् के सुधार के जलए िहीं दकया िाएगा; (iv) अजधकतम स्ट्र्ीकायव त्रुठटयााँ (एमपीई),–12 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] सारणी 2. गैस मीटर की अजधकतम स्ट्र्ीकायव त्रुठटयााँ प्रर्ाह िर Q मॉडल अिुमोिि और प्रारंजभक सत्यापि के पुिः सत्यापि और सेर्ाकाल के िौराि िौराि सटीकता र्गव सटीकता र्गव 0.5 1 1.5 0.5 1 1.5 Q ≤ Q <Q ± 1 % ± 2 % ± 3 % ± 2 % ± 4 % ± 6 % min t Q ≤ Q ≤ Q ± 0.5 % ± 1 % ± 1.5 % ± 1 % ± 2 % ± 3 % t max (v) अंतर्िवर्मवत रूपांतरण जडर्ाइस र्ाला गैस मीटर,– अंतर्िवजहत रूपांतरण जडर्ाइस र्ाले गैस मीटर के जलए और केर्ल आधार जस्ट्थजतयों पर आयति प्रिर्िवत करि े के जलए, सारणी 2 में जर्जिर्िवष्ट की गई अजधकतम अिुमेय त्रुठटयााँ (tsp – 15) °C से (tsp + 15) °C के तापमाि रेंि में 0.5% तक बढ़ िाती ह।ैं इस तापमाि रेंि के बाहर 10 °C के अजतठरि अंतराल पर इस जर्स्ट्ताठरत एमपीई म ें 0.5% की अजतठरि र्ृजद् की अिुमजत ह।ै तापमाि tspis जर्जिमावता द्वारा जिर्िष्टव दकया िाता ह।ै ठटप्पण 1: रूपांतरण तापमाि या िबार् माप या िोिों पर आधाठरत हो सकता ह।ै ठटप्पण 2: र्ास्ट्तजर्क आयति और आधार जस्ट्थजतयों पर आयति िोिों को ििाविे र्ाल े गैस मीटर को गैस मीटटरंग जसस्ट्टम मािा िाता ह।ै (4) भाठरत माध्य त्रुठट (डब्लूएमई),– भाठरत औसत त्रुठट (डब्लूएमई) सारणी 3 में दिए गए मािों के भीतर होगी। सारणी 3. अजधकतम स्ट्र्ीकायव भाठरत औसत त्रुठट प्रर्ाह िर Q मॉडल अिुमोिि और प्रारंजभक सत्यापि के पुिः सत्यापि और सेर्ाकाल के िौराि िौराि सटीकता र्गव सटीकता र्गव 0.5 1 1.5 0.5 1 1.5 (1) (2) (3) (4) (5) (6) (7) डब्लूएमई ± 0.2 % ± 0.4 % ± 0.6 % - - - (5) सील की मरम्मत और िजत,– गैस मीटर के घटकों की मरम्मत के बाि िो मेरोलॉजिकल व्यर्हार को प्रभाजर्त करते ह ैं या सील को िुकसाि पहुचाँ ािे के बाि, अजधकतम स्ट्र्ीकायव त्रुठट प्रारंजभक सत्यापि पर त्रुठटयों के अिरूु प होगी िैसा दक सारणी 2 में जर्जिर्िवष्ट ह,ै साथ ही अजधकतम स्ट्र्ीकायव भाठरत औसत त्रुठट िैसा दक सारणी 3 में जर्जिर्िवष्ट ह;ै (6) पिु रुत्पािकता,– Q के बराबर या उससे अजधक प्रर्ाह िरों के जलए, जर्जिष्ट प्रर्ाह िर पर त्रुठट की पुिरुत्पािकता अजधकतम स्ट्र्ीकायव त्रुठट t के एक जतहाई से कम या उसके बराबर होगी;[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 13 (7) पिु रार्ृजि,– जर्जिष्ट प्रर्ाह िर पर लगातार तीि मापों की त्रुठट की पिु रार्ृजि अजधकतम स्ट्र्ीकायव त्रुठट के एक जतहाई से कम या उसके बराबर होगी; (8) कायव िबार्,– पैरा 4 के उप-पैरा (3) में उजल्लजखत अपेिाओं को पूरे कायव िबार् रेंि में पूरा दकया िाएगा; (9) तापमाि,– पैरा 4 के उप-परै ा (3) में उजल्लजखत अपिे ाओं को परू े तापमाि रेंि म ें पूरा दकया िाएगा, िहााँ पठरर्ेि का तापमाि 5 °C के भीतर गैस के तापमाि के बराबर होता ह।ै केर्ल आधार जस्ट्थजतयों पर आयति ििावि े र्ाले गैस मीटरों के जलए, Q के बराबर या उससे अजधक प्रर्ाह िरों के जलए t अजधकतम स्ट्र्ीकायव त्रुठट सीमाएाँ तब लाग ू होती ह ैं िब पठरर्िे का तापमाि गैस के तापमाि से 20 °C या उससे अजधक जभन्न होता ह।ै (10) स्ट्थाजयत्र्,– गैस मीटर 0.8 Q और Q के बीच की िर र्ाल े प्रर्ाह के अधीि होि े के बाि जिम्नजलजखत अपेिाओं को परू ा करेगा, max max जिसमें 2000 घंटों की अर्जध के िौराि Q पर प्रर्ाह के बराबर मात्रा िाजमल ह,ै अथावत्:- max (i) पिु ः सत्यापि और प्रयोग के जलए सारणी 2 में जिर्िष्टव अजधकतम स्ट्र्ीकायव त्रुठटयााँ; और (ii) Q स ेQ तक प्रर्ाह िरों के जलए जिम्न से कम या बराबर की खराबी,– t max - र्ग व1.5 के जलए मॉडल अिुमोिि के िौराि लाग ूअजधकतम स्ट्र्ीकायव त्रुठट का 1.0 गुिा या - अन्य र्गों के जलए मॉडल अिमु ोिि के िौराि लाग ूअजधकतम स्ट्र्ीकायव त्रुठट का 0.5 गिु ा। (11) ओर्रलोड प्रर्ाह,– 1 घंटे की अर्जध के जलए 1.2 Q के ओर्रलोड के संपकव में आिे के बाि, एक गैस मीटर जिम्नजलजखत अपिे ाओं का max अिुपालि करेगा,– (i) परै ा 4 के उप-पैरा (3) में उजल्लजखत अजधकतम स्ट्र्ीकायव त्रुठटयााँ; और (ii) अजधकतम स्ट्र्ीकायव त्रुठट के एक जतहाई से कम या बराबर की खराबी। (12) कंपि और झटके,– एक गैस मीटर जिम्नजलजखत जर्जििेिों के साथ कंपि और झटकों का सामिा करेगा:14 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (i) कंपि,– कुल आर्ृजि रेंि: 10 हर्टि व – 150 हर्टि व कुल आरएमएस स्ट्तर: 7 m.s-2 एएसडी स्ट्तर 10 हर्टिव – 20 हर्टिव: 1 m2s-3 एएसडी स्ट्तर 20 हर्टिव – 150 हर्टिव: –3 dB/ऑक्टेर् (ii) झटके,– िॉल की ऊंचाई: 50 mm कंपि और िॉक्स के प्रयोग के बाि िोष अजधकतम स्ट्र्ीकायव त्रुठट के 0.5 गुिा से कम या उसके बराबर होगा। (13) जिर्िष्टव प्रकार के गैस मीटरों के जलए मापजर्ज्ञाि जर्जिष्ट अपेिाएं,– (i) अजभजर्न्यास,– यदि मीटर का जर्जिमावता जिर्िवष्ट करता ह ै दक मीटर केर्ल कुि जिजश्चत अजभजर्न्यासों में स्ट्थाजपत होिे पर ही सही ढगं स े काम करेगा और यदि मीटर को इस प्रकार जचजह्ित दकया गया है, तो पैरा 4 के उप-पैरा (3) और (4) में जर्जिर्िवष्ट माप संबंधी अपेिाएं केर्ल इि अजभजर्न्यासों के जलए पूरी की िाएगं ी; ऐसे जचह्िों की अिपु जस्ट्थजत में मीटर सभी अजभजर्न्यासों के जलए इि अपेिाओं को परू ा करेगा; (ii) प्रर्ाह दििा,– यदि मीटर को िोिों दििाओं म ें प्रर्ाह को मापि े म ें सिम के रूप में जचजह्ित दकया गया है, तो परै ा 4 के उप-परै ा (3) और (4) म ेंजर्जिर्िवष्ट माप संबंधी अपेिाएं प्रत्येक दििा के जलए अलग-अलग परू ी की िाएगं ी; (iii) प्रर्ाह बाधा,– गैस मीटर के प्रकारों के जलए जििकी सटीकता प्रर्ाह ग़िब़िी से प्रभाजर्त होती है, इि ग़िबज़ियों के कारण त्रुठट का बिलार् अजधकतम स्ट्र्ीकायव त्रुठट के एक जतहाई से अजधक िहीं होगा। यदि ऐसे गैस मीटर को केर्ल हल्की प्रर्ाह ग़िब़िी पैिा करिे र्ाली जर्जिष्ट पाइप्पंग व्यर्स्ट्था म ें स्ट्थाजपत करि े के जलए जिर्िवष्ट दकया िाता है, तो मीटर को इस तरह से जचजह्ित दकया िाएगा और केर्ल उि जर्जिष्ट पाइप्पगं जर्न्यासों में स्ट्थाजपत दकया िा सकता ह ै जििके जलए इसकी सटीकता इस अपेिा के भीतर रहिे के जलए जसद् हुई ह;ै (iv) ड्राइर् िाफ्ट (टॉकव),– एक या अजधक ड्राइर् िाफ्ट र्ाले गैस मीटर के प्रकारों के जलए, जिमावता द्वारा जिर्िवष्ट अजधकतम टॉकव के आर्ेिि स े होि े र्ाली कोई भी खराबी अजधकतम स्ट्र्ीकायव त्रुठट के एक जतहाई से अजधक िहीं होगी; (v) जर्जभन्न गैसें,– जर्जभन्न गैसों के जलए उपयोग दकए िािे र्ाले गैस मीटर के प्रकार, गैसों की पूरी श्रृंखला के जलए पैरा 4 के उप-पैरा (3) म ें उजल्लजखत मापजर्ज्ञाि संबंधी अपेिाओं का अिुपालि करेंगे, जििके जलए उन्ह ेंजर्जिमावता द्वारा जिर्िवष्ट दकया गया ह;ै[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 15 (vi) जर्जिमेय घटक,– ऐसे गैस मीटरों के जलए जििके कुि घटकों को पठरचालि उद्देश्यों (िैसे अल्रासोजिक रांसड्यूसर या मीटर कार्ट्रवि) के जलए जर्जिमेय बिाया गया ह,ै ऐस े घटक के जर्जिमेय होिे के कारण होिे र्ाली खराबी प्रकार मूल्यांकि के िौराि लाग ू अजधकतम स्ट्र्ीकायव त्रुठट के एक जतहाई से अजधक िहीं होगी, िबदक त्रुठट दकसी भी मामले में उस सीमा के जलए अजधकतम स्ट्र्ीकायव त्रुठट से अजधक िहीं होगी; (vii) इलेक्रॉजिक्स,– यदि दकसी गैस मीटर में इलेक्रॉजिक घटक िाजमल ह,ैं तो सारणी 4 और सारणी 5 म ेंजर्जिर्िवष्ट अपेिाएं लाग ूहोती ह;ैं (viii) सहायक उपकरणों स ेप्रभाजर्त,– सहायक उपकरणों से युि गैस मीटरों को इस प्रकार जडिाइि दकया िाएगा दक सहायक उपकरणों के सभी कायव (िैस े संचार उद्देश्यों के जलए उपबंध) मेरोलॉजिकल व्यर्हार को प्रभाजर्त ि करें। सारणी 4. इलक्े रॉजिक घटकों र्ाल ेगसै मीटरों के जलए अपिे ाएं स ं प्रभार् कारक रेंि त्रुठट सीमा (1) (2) (3) (4) (क) िुष्क ऊष्मा ऊपरी तापमाि जिर्िष्टव एमपीई (ख) िंडी ऊष्मा ऊपरी तापमाि जिर्िष्टव एमपीई (ग) िम ऊष्मा, जस्ट्थर अर्स्ट्था(गैर- ऊपरी तापमाि जिर्िष्टव , एमपीई संघिक) 93% सापेि आद्रतव ा (घ) डीसी मेि र्ोल्टेि जभन्नता (1) जर्जिमावता द्वारा जिर्िवष्ट एमपीई (ङ) एसी मेि र्ोल्टेि जभन्नता (1) रेटेड र्ोल्टेि का 85% और 110% एमपीई (च) आंतठरक बैटरी का कम र्ोल्टेि (1) जर्जिमावता द्वारा जिर्िवष्ट एमपीई (1) यदि लागू हो सारणी 5. इलक्े रॉजिक घटकों र्ाल ेगसै मीटरों के जलए प्रजतरिा अपिे ाएाँ स ं बाधा अपजे ित प्रजतरिा िोष सीमा / परीिण ित(ें 3) (1) (2) (3) (4) (क) िम गमी चक्रीय ऊपरी तापमाि, जिर्िवष्ट 93% सापेि आद्रतव ा ½ एमपीई / एिएसएिए (संघिक) (ख) कंपि (यािजृ छिक) कुल आर्ृजि रेंि: 10 हर्टि व – 150 हर्टि व ½ एमपीई / एिएसएिए कुल आरएमएस स्ट्तर: 7 मी.से-2 एएसडी स्ट्तर 10 हर्टिव–20 हर्टिव: 1 मी2.स-े3 एएसडी स्ट्तर 20 हर्टिव–150 हर्टिव: –3डीबी/ऑक्टेर् (ग) यांजत्रक झटका 50 जममी ½ एमपीई / एिएसएिए (घ) जर्दकरजणत रेजडयो 10 V/m, 3 GHz तक एमपीई / एिएसएिए दफ्रिेंसी, जर्द्युत चुम्बकीय16 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] ित्रे (ङ) रेजडयो दफ्रिेंसी, जर्द्युत 10 V (e.m.f.), 80MHz तक एमपीई / एिएसएिए चुम्बकीय िेत्रों द्वारा उत्पन्न संचाजलत (साधारण मोड) धाराएं (च) इलेक्रोस्ट्टैठटक जडस्ट्चाि व 6 kV संपकव जिर्वहि ½ एमपीई / एिएसएिए+डी 8 kV र्ायु जिर्वहि (ि) संकेत, डेटा और जियंत्रण आयाम 1 kV ½ एमपीई / एिएसएिए रेखाओं पर जर्स्ट्िोट पुिरार्ृजि िर 5 kHz (िजणक) (ि) संकेत, डेटा और जियंत्रण असमजमत रेखाएाँ: ½ एमपीई / एिएसएिए रेखाओं पर सि व लाइि स ेलाइि 0.5 kV लाइि स ेग्राउंड 1.0 kV समजमत रेखाएाँ: लाइि स ेलाइि एिए लाइि स ेग्राउंड 1.0 kV पठररजित इिपुट/ऑउटपुट और संचार रेखाए:ाँ लाइि स ेलाइि एिए लाइि स ेग्राउंड 0.5 kV (झ) एसी मेि र्ोल्टेि जडप्स ½ चक्र 0 % ½ एमपीई / एिएसएिए और िॉटव इंटरप्ट(1) 1 चक्र 0 % 10/12(2) चक्र 40 % 25/30(2) चक्र 70 % 250/300(2) चक्र 80 % (ञ) डीसी मेि र्ोल्टेि जडप्स 0.1 सेकंड के िौराि रेटेड र्ोल्टेि का 40% ½ एमपीई / एिएसएिए और िॉटव इंटरप्ट(1) और 70% तथा 0.01 सेकंड के िौराि रेटेड र्ोल्टेि का 0% (ट) एसी और डीसी मेि पर आयाम 2 kV ½ एमपीई / एिएसएिए जर्स्ट्िोट (िजणक) पुिरार्ृजि िर 5 kHz (ि) एसी और डीसी मेि पर लाइि स ेलाइि 1.0 kV ½ एमपीई / एिएसएिए+डी उिाल लाइि स ेिमीि 2.0 kV (ड) डीसी मेि पार्र पर िाममात्र डीसी र्ोल्टेि का 2% ½ एमपीई / एिएसएिए तरंग(1) (1) यदि लाग ूहो (2) क्रमिः 50 हर्टिव/60 हर्टिव के जलए (3)एिएसएिए: बाधा के बाि कोई महत्र्पूणव िोष िहीं होगा। एिएसएिडी: बाधा के िौराि कोई महत्र्पूणव िोष िहीं होगा। क्रम संख्या (ङ) (ि) और (ि) म ेंजर्जिर्िवष्ट परीिण गरै -मख्ु य किेक्टेड गैस मीटर के जलए लाग ूिहीं ह।ैं क्रम संख्या (ट) और (ि) म ेंपरीिण लाग ूिहीं होत े ह ैंयदि मीटर एसी या डीसी मेन्स से ि़िु ा िहीं ह।ै[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 17 5. तकिीकी अपिे ाए.ं – (1) जिमाणव ,– (i) सामग्री,– गैस मीटर ऐसी सामग्री स े बिा होगा और इस तरह से बिाया िाएगा दक र्ह भौजतक, रासायजिक और तापीय पठरजस्ट्थजतयों का सामिा कर सके, जिससे र्ह प्रभाजर्त हो सकता ह ै और अपिे परू े िीर्िकाल म ें अपिे इजछित प्रयोििों को सही ढंग स ेपूरा कर सके; (ii) केस की मिबूती,– गैस मीटर का केस राष्ट्रीय या अंतराष्ट्रव ीय मािकों और सुरिा संबंधी अपेिाओं के अिुसार जिर्िवष्ट गैस-टाइट होिा चाजहए और गैस मीटर के अजधकतम कायव िबार् से कम से कम 1.5 गिु ा तक होिा चाजहए। यदि मीटर को खुली हर्ा में स्ट्थाजपत दकया िािा ह ैतो यह बहते पािी के जलए अभेद्य होिा चाजहए; (iii) संघिि/िलर्ायु उपबधं ,– जर्जिमावता उि िगहों पर संघिि को कम करिे के जलए उपकरणों को िाजमल कर सकता है, िहां संघिि उपकरण के प्रििवि को प्रजतकूल रूप से प्रभाजर्त कर सकता ह;ै (iv) बाहरी हस्ट्तिेप से सुरिा,– गैस मीटर का जिमावण और स्ट्थापिा इस तरह से की िाएगी दक इसकी सटीकता को प्रभाजर्त करिे म ें सिम यांजत्रक हस्ट्तिेप या गैस मीटर या सत्यापि जचह्िों या सुरिा जचह्िों को स्ट्थायी रूप से दिखाई िेिे र्ाले िुकसाि को रोका िा सके; (v) संकेत उपकरण,– संकेतक उपकरण को मीटर बॉडी से भौजतक रूप से या िरू से िो़िा िा सकता ह।ै बाि के मामले में प्रिर्िवत दकए िािे र्ाल े डेटा को गैस मीटर म ेंसंग्रहीत दकया िाएगा; ठटप्पण: ग्राहकों और उपभोिाओं के जलए डेटा तक पहुचं के उपबंध होंगे। (vi) सुरिा उपकरण,– गैस मीटर को एक सुरिा उपकरण से सुसजित दकया होगा, िो भूकंप या आग िैसी आपिाओं की जस्ट्थजत में गैस के प्रर्ाह को बंि कर िेता ह।ै गैस मीटर स े एक सरु िा उपकरण िो़ििा होगा, परंत ु दक यह मीटर की मेरोलॉजिकल अखडं ता को प्रभाजर्त ि करे। भूकंप सेंसर और जर्द्युत चाजलत र्ाल्र् से सुसजित एक यांजत्रक गैस मीटर को इलेक्रॉजिक गैस मीटर िहीं मािा िाता है; (vii) इलेक्रॉजिक भागों के बीच किेक्िि,– इलेक्रॉजिक भागों के बीच किक्े िि जर्श्वसिीय और ठटकाऊ होिे चाजहए;18 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (viii) घटक,– मीटर के घटकों को जबिा पिु ः सत्यापि के तभी बिला िा सकता ह ै िब मॉडल अिुमोिि यह स्ट्थाजपत करता ह ै दक मीटर के मेरोलॉजिकल गुण और जर्िषे रूप से सटीकता संबंजधत घटकों के आिाि-प्रिाि से प्रभाजर्त िहीं होती ह ै[पैरा 4 के उप- पैरा (13) का खडं (vi) िेख]ें । ऐसे घटकों को जर्जिमावता द्वारा उिके अपि े जर्जिष्ट भाग सख्ं या या पहचािकतावओं द्वारा पहचािा िाएगा। ठटप्पण: इि घटकों को मीटर के मॉडल (मॉडल) के साथ जचजह्ित दकया िाएगा, जिससे उन्ह ें िो़िा िा सकता ह ै और उन्ह ें बिलिे की अपेिा हो सकती ह।ै (ix) िन्ू य प्रर्ाह,– िब प्रर्ाह िर िून्य होती ह,ै तो गैस मीटर का समग्रीकरण िहीं बिलगे ा और संस्ट्थापि की जस्ट्थजतयााँ प्रर्ाह स्ट्पंिि से मिु होती ह।ैं ठटप्पण: यह अपेिा जस्ट्थर पठरचालि जस्ट्थजतयों को संिर्भवत करती ह।ै यह जस्ट्थजत गैस मीटर की बिली हुई प्रर्ाह िरों पर प्रजतदक्रया को संिर्भवत िहीं करती ह।ै (2) प्रर्ाह दििा,– (i) गैस प्रर्ाह की दििा,– एक गैस मीटर पर िहां संकेत उपकरण गैस प्रर्ाह की केर्ल एक दििा के जलए सकारात्मक रूप से पंिीकृत होता ह,ै इस दििा को एक ऐसी जर्जध द्वारा इंजगत दकया िाएगा जिसे स्ट्पष्ट रूप से समझा िा सके, िैसे दक एक तीर। यदि गैस प्रर्ाह की दििा जिमावण द्वारा जिधावठरत की िाती ह ैतो इस संकेत की अपिे ा िहीं ह;ै (ii) प्लस और माइिस जचह्ि,– जर्जिमावता यह जिर्िष्टव करेगा दक गैस मीटर जद्व-दििात्मक प्रर्ाह को मापि े के जलए जडजाइि दकया गया ह ै या िहीं। जद्व- दििात्मक प्रर्ाह के मामले में धिात्मक और ऋणात्मक जचह्ि के साथ िो जसर र्ाला तीर इस्ट्तेमाल दकया िाएगा, जिसस े यह संकेत जमलता ह ैदक दकस प्रर्ाह दििा को क्रमिः सकारात्मक और िकारात्मक मािा िाता ह;ै (iii) जद्व-दििात्मक प्रर्ाह की ठरकॉर्डिंग,– यदि मीटर जद्व-दििात्मक उपयोग के जलए जडजाइि दकया गया ह,ै तो ठरर्सव फ्लो के िौराि प्रर्ाजहत गैस की मात्रा को या तो संकेजतत मात्रा स े घटाया िाएगा या अलग से ठरकॉडव दकया िाएगा। अजधकतम स्ट्र्ीकायव त्रुठटयााँ आग े और पीिे िोिों प्रर्ाह के जलए पूरी की िाएंगी; (iv) ठरर्सव फ्लो,– यदि मीटर ठरर्सव फ्लो को मापिे के जलए जडजाइि िहीं दकया गया ह,ै तो मीटर या तो ठरर्सव फ्लो को रोक िगे ा, या यह आग े के प्रर्ाह माप के संबंध म ें अपि े मेरोलॉजिकल गणु ों में जगरार्ट या पठरर्तवि के जबिा आकजस्ट्मक या आकजस्ट्मक ठरर्सव फ्लो का सामिा करेगा; (v) संकेतक उपकरण,– गैस मीटर म ें एक उपकरण लगाया िा सकता है, जिससे िब भी गैस अिजधकृत दििा में प्रर्ाजहत हो, तो संकेतक उपकरण को काम करिे स ेरोका िा सके;[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 19 (3) संकेतक उपकरण,– (i) साधारण उपबंध: गैस मीटर से ि़िु ा संकेतक उपकरण, मापी गई गैस की मात्रा को आयति या द्रव्यमाि में संगत इकाइयों में ििावएगा। रीप्डगं स्ट्पष्ट और साि होिी चाजहए। संकेत उपकरण हो सकता ह,ै– (क) पैरा 5 के उप-पैरा (3) के खडं (iv) म ेंजर्जिर्िवष्ट एक यांजत्रक संकेत उपकरण; (ख) पैरा 5 के उप-पैरा (3) के (v) म ेंजर्जिर्िवष्ट एक इलेक्रोमैकेजिकल या इलेक्रॉजिक संकेत उपकरण; (ग) (क) और (ख) का संयोिि। संकेत िेि े र्ाल े उपकरण रीसेट िहीं दकय े िा सकेंग े और र्ाष्पिील िहीं होंग े अथावत ् र् े उपकरण के बीच म ें आई जर्द्युत जर्िलता से उबरि े के बाि अंजतम सग्रं हीत संकेत दिखािे में सिम होंगे। िहां संकेत िेि े र्ाला उपकरण मापी गई मात्रा के ििमलर् उपगुणकों को दिखाता है, इस अिं को पूणािंक माि स े स्ट्पष्ट ििमलर् जचह्ि द्वारा अलग दकया िाएगा। अन्य संकेतों के जलए भी एक जडस्ट्प्ल े का उपयोग करिा संभर् हो सकता है, िब तक दक यह स्ट्पष्ट हो दक कौि सी मात्रा प्रिर्िवत की िा रही ह।ै (ii) संकेत सीमा,– संकेतक उपकरण अजधकतम प्रर्ाह िर Q पर कम स े कम 1000 घंटों के संचालि के अिरूु प गैस की संकेजतत max मात्रा को ठरकॉडव करि े और प्रिर्िवत करिे म ेंसिम होगा, जबिा मूल रीप्डगं पर र्ापस आए। (iii) संकल्प,– सबसे कम महत्र्पूणव अंक के अिुरूप मात्रा Q पर एक घंटे के िौराि प्रर्ाजहत गैस की मात्रा से अजधक िहीं होगी। min यदि सबसे िोटा महत्र्पूणव अंक (अंजतम ड्रम में) मापी गई मात्रा का ििमलर् गुणक ििावता है, तो इलेक्रॉजिक जडस्ट्प्ल े के िेसप्लेट पर जिम्नजलजखत अंदकत होगा: (क) या तो अंजतम ड्रम या अंक एक या िो या तीि आदि जिजश्चत िून्य के बाि; या (ख) अंकि: "× 10" या "× 100", या "× 1000", आदि, तादक रीप्डंग हमेिा पैरा 3 के उप-पैरा (1) में जर्जिर्िवष्ट इकाइयों में हो। (iv) यांजत्रक संकेति उपकरण,– अंकों की न्यूितम ऊंचाई 4.0 जममी तथा उिकी न्यूितम चौ़िाई 2.4 जममी होगी। यांजत्रक संकेति युजि का अंजतम तत्र् (अथावत सबसे कम महत्र्पूणव पैमाि े अंतराल र्ाला ििक) अन्य ििकों स े प्रििवि के तरीके में जभन्न हो सकता ह।ै ड्रम संकेति युजि के मामले म ें दकसी भी क्रम की आकृजत की एक इकाई द्वारा अजग्रम परू ी तरह से तब होगी िब तुरंत िीच े के क्रम की आकृजत अपिे कोसव के अंजतम िसर्ें भाग स ेगुजरेगी।20 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (v) इलक्े रोमैकेजिकल या इलेक्रॉजिक संकेतक उपकरण,– माप की अर्जध के िौराि गैस की मात्रा का जिरंतर प्रिििव आज्ञापक िहीं ह।ै इलेक्रॉजिक संकेतक उपकरण को जडस्ट्प्ल े टेस्ट्ट के साथ प्रिाि दकया िाएगा। (vi) ठरमोट इंजडकेटटंग उपकरण,– यदि इंजडकेटटंग उपकरण का उपयोग ठरमोट तरीके स े दकया िाता है, जिससे संबंजधत गैस मीटर को स्ट्पष्ट रूप से पहचािा िाएगा। यंत्र और इंजडकेटटंग उपकरण के बीच संचार की प्रामाजणकता की िााँच की िाएगी। ठटप्पण: संबंजधत गैस मीटर की सीठरयल संख्या का उपयोग स्ट्पष्ट पहचाि के जलए दकया िा सकता ह।ै (4) परीिण तत्र्,– (i) साधारण,– गैस मीटर को इस प्रकार जडिाइि और जिर्मवत दकया िाएगा,– (क) एक अजभन्न परीिण तत्र्; या (ख) एक पल्स ििरेटर; या (ग) एक पोटेबल परीिण इकाई के किेक्िि की अिुमजत िेि े र्ाली व्यर्स्ट्था। (ii) इंटीग्रल परीिण तत्र्,– इंटीग्रल परीिण तत्र् में यांजत्रक संकेत उपकरण का अंजतम तत्र् जिम्नजलजखत में से दकसी एक रूप म ें िाजमल हो सकता ह,ै– (क) एक जिरंतर गजतिील ड्रम जिसमें एक पैमािा होता ह,ै िहााँ ड्रम पर प्रत्येक उपजर्भािि को परीिण तत्र् की र्ृजद् के रूप में मािा िाता ह;ै (ख) एक जिजश्चत डायल पर एक स्ट्केल के साथ घूमिे र्ाला पॉइंटर, या एक जिजश्चत संिभ व जचह्ि स े आग े बढ़ि े र्ाल े स्ट्केल के साथ एक जडस्ट्क, िहा ं डायल या जडस्ट्क पर प्रत्येक उपजर्भािि को परीिण तत्र् की र्ृजद् के रूप में मािा िाता ह।ै परीिण तत्र् के क्रमांदकत स्ट्केल पर पॉइंटर के एक पणू व चक्कर का माि इस रूप म ेंििावया िाएगा: "1 चक्कर = m3 या kg या …… <इकाई>"। स्ट्केल की िरुु आत िून्य अंक से ििावई िाएगी। स्ट्केल अंतराल 1 जममी से कम िहीं होगा तथा परू े स्ट्केल में जस्ट्थर रहगे ा। स्ट्केल अतं राल 1 × 10n, 2 × 10n, या 5 × 10n m3 या दकग्रा या …… <इकाई> (n एक धिात्मक या ऋणात्मक पणू व संख्या या िून्य ह)ै के रूप म ेंहोगा। पैमािे के जििाि बारीक और एक समाि रूप से खींचे िाि े चाजहए। इलेक्रॉजिक संकेत उपकरण के साथ अंजतम अंक को अजभन्न परीिण तत्र् के रूप में उपयोग दकया िाता ह।ै भौजतक या इलेक्रॉजिक माध्यम से एक जर्जिष्ट परीिण मोड ििव दकया िा सकता ह ै जिसमें अंकों की संख्या बढ़ाई िा सकती ह ै या संकल्प प्राप्त करि े के जलए कुि र्ैकजल्पक जर्जध लागू की िा सकती ह।ै[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 21 यदि गैस मीटर पर लागू हो, तो परीिण तत्र् चक्रीय आयति के प्रायोजगक जिधावरण की अिमु जत िेगा। चक्रीय आयति के मापे गए माि और उसके िाममात्र माि के बीच का अंतर संिभव जस्ट्थजतयों में बाि के माि के 5% से अजधक िहीं होिा चाजहए; (iii) पल्स ििरेटर,– यदि गैस मीटर पर आयति या द्रव्यमाि की इकाइयों म ें व्यि एक पल्स का माि अंदकत है, तो पल्स ििरेटर को परीिण तत्र् के रूप में इस्ट्तेमाल दकया िा सकता ह।ै गैस मीटर का जिमावण इस प्रकार दकया िाएगा दक पल्स माि को प्रयोगात्मक रूप स े िांचा िा सके। पल्स माि के माप े गए माि और गैस मीटर पर ििावए गए माि के बीच का अंतर, बाि र्ाले माि के 0.05% से अजधक िहीं होगा; (iv) सलं ग्न परीिण उपकरण,– संकेतक उपकरण म ें पूरक तत्र्ों (िैसे स्ट्टार व्हील या जडस्ट्क) को िाजमल करके परीिण के जलए उपबंध िाजमल हो सकत े हैं, िो संलग्न परीिण उपकरण के जलए संकेत प्रिाि करत े ह।ैं संलग्न परीिण उपकरण का उपयोग परीिण तत्र् के रूप म ें दकया िा सकता ह ै यदि एक पल्स का माि, मात्रा या द्रव्यमाि की इकाइयों में व्यि दकया िाता ह,ै गैस मीटर पर अंदकत दकया िाता ह;ै (v) परीिण तत्र् या पल्स की र्ृजद्,– परीिण तत्र् या पल्स की र्ृजद् Q पर कम से कम हर 60 सके ंड में होगी। min (5) सहायक उपकरण,– (i) साधारण,– गैस मीटर म ें सहायक उपकरण िाजमल हो सकत े हैं, जिन्ह ें स्ट्थायी रूप स े िाजमल दकया िा सकता ह ै या अस्ट्थायी रूप स े िो़िा िा सकता ह।ै अिुप्रयोगों के उिाहरण इस प्रकार हैं,– (क) संकेत उपकरण पर स्ट्पष्ट रूप से दिखाई िेिे से पहल े प्रर्ाह का पता लगािा; (ख) परीिण, सत्यापि और िरू स्ट्थ रीप्डंग के जलए साधि; (ग) पूर्व भुगताि; सहायक उपकरण उपकरण के सही संचालि को प्रभाजर्त िहीं करेंगे। यदि कोई सहायक उपकरण जर्जधक माप जर्ज्ञाि जियंत्रण के अधीि िहीं ह,ै तो इसे स्ट्पष्ट रूप से इंजगत दकया िािा चाजहए; (ii) ड्राइर् िाफ्ट की सुरिा,– िब संलग्न सहायक उपकरण स े किेक्ट िहीं दकया िाता ह,ै तो ड्राइर् िाफ्ट के उिागर जसरों को उजचत रूप स े संरजित दकया िाएगा; (iii) टॉकव ओर्रलोड,– मापि रांसड्यूसर और मध्यर्ती जगयटरंग के बीच किेक्िि टूटेगा या बिलेगा िहीं, यदि परै ा 6 के उप-परै ा (1) के खडं (iii) के उप-खंड (ख) और पैरा 6 के उप-पैरा (1) के खंड (iii) के उप-खंड (ग) में संकेजतत अिुमेय टॉकव से तीि गिु ा अजधक टॉकव लगाया िाता ह।ै22 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (6) जबिली स्रोत,– (i) जबिली स्रोतों के प्रकार,– गैस मीटर को जिम्न द्वारा संचाजलत दकया िा सकता ह,ै अथावत्:- (क) मुख्य जबिली स्रोत; (ख) गैर-प्रजतस्ट्थापिीय जबिली स्रोत; या (ग) प्रजतस्ट्थापिीय जबिली स्रोत। इि तीि प्रकार के जबिली स्रोतों का उपयोग अकेल ेया संयोिि में दकया िा सकता ह।ै ठटप्पण: इस भाग के प्रयोिि के जलए, ठरचािेबल जबिली स्रोतों को प्रजतस्ट्थापिीय मािा िाता ह।ै (ii) मख्ु य जबिली,– इलेक्रॉजिक गैस मीटर को यह सुजिजश्चत करते हुए इस तरह स ेजडजाइि दकया िाएगा दक मुख्य जबिली जर्िलता (एसी या डीसी) की जस्ट्थजत म,ें जर्िलता से िीक पहल े गैस की मात्रा का मीटर संकेत खो ि िाए, और जर्िलता के बाि जबिा दकसी कठििाई के पढ़ि े के जलए सलु भ रह।े जर्द्युत आपूर्तव म ेंरुकार्ट स ेमीटर के दकसी अन्य गुण या परै ामीटर पर कोई प्रभार् िहीं प़िगे ा। ठटप्पण: इस अपेिा का अिुपालि यह सुजिजश्चत करेगा दक गसै मीटर जबिली की जर्िलता (यांजत्रक असेंबली के माध्यम से हो सकता ह)ै के िौराि गैस मीटर से गुिरिे र्ाली गैस की मात्रा को पंिीकृत करिा िारी रखेगा। मुख्य जर्द्युत स्रोत से किेक्िि को िे़ििा़ि से सुरजित रखा िाएगा। (iii) गैर-प्रजतस्ट्थापिीय जबिली स्रोत,– जिमावता यह सुजिजश्चत करेगा दक जबिली स्रोत का संकेजतत िीर्िकाल यह गारंटी िते ा ह ै दक मीटर कम स े कम मीटर के पठरचालि िीर्िकाल तक सही ढंग से कायव करता ह ैजिसे मीटर पर जचजह्ित दकया िाएगा या र्ैकजल्पक रूप से, समय की इकाइयों में िेष बैटरी िमता को इलेक्रॉजिक संकेत उपकरण पर प्रस्ट्तुत दकया िा सकता ह।ै (iv) प्रजतस्ट्थापिीय जबिली स्रोत,– यदि उपकरण प्रजतस्ट्थापिीय जबिली स्रोत द्वारा संचाजलत ह,ै तो जिमावता इसके प्रजतस्ट्थापि के जलए जर्स्ट्तृत जर्जििेि िेगा। जिस जतजथ तक जबिली स्रोत को प्रजतस्ट्थाजपत दकया िािा ह,ै र्ह मीटर पर इंजगत की िाएगी। र्ैकजल्पक रूप से, जबिली स्रोत का अिुमाजित िषे िीर्ि प्रिर्िवत दकया िाएगा या चेतार्िी िी िाएगी िब जबिली स्रोत का अिुमाजित िेष िीर्ि 10% या उससे कम हो। जबिली स्रोत के प्रजतस्ट्थापि के िौराि मीटर के गुण और परै ामीटर प्रभाजर्त िहीं होंगे। मेरोलॉजिकल सील को तो़ि े जबिा जबिली स्रोत को बिलिा सभं र् होगा। जबिली स्रोत के कम्पाटवमेंट को िे़ििा़ि से सुरजित दकया िा सकेगा।[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 23 (7) इलक्े रॉजिक गसै मीटर के जलए िाचाँ , सीमाएाँ और अलाम,व– (i) िाचाँ ,– इलेक्रॉजिक गैस मीटर को जिम्नजलजखत की िााँच करिे की अपिे ा होती है,– (क) रांसड्यूसर और महत्र्पूणव उपकरणों की उपजस्ट्थजत और सही कायवप्रणाली; (ख) सग्रं हीत, प्रेजषत और संकेजतत डेटा की अखंडता; और (ग) पल्स रांसजमिि (यदि लाग ूहो)। ठटप्पण: पल्स रांसजमिि िााँच गायब पल्स, या हस्ट्तिपे के कारण अजतठरि पल्स पर ध्याि केंदद्रत करती ह।ै उिाहरण स्ट्र्रूप डबल पल्स जसस्ट्टम, थ्री-पल्स जसस्ट्टम या पल्स टाइप्मंग जसस्ट्टम। (ii) सीमाए,ाँ – गैस मीटर में यह पता लगािे और उस पर कारवर्ाई करिे की िमता भी हो सकती ह:ै (क) ओर्रलोड प्रर्ाह की जस्ट्थजत; (ख) माप पठरणाम िो रांसड्यसू र के अजधकतम और न्यिू तम मूल्यों से बाहर हैं; (ग) मापी गई मात्राएाँ िो कुि पूर्व-प्रोग्राम की गई सीमाओं से बाहर ह,ैं और (घ) ठरर्सव फ्लो। यदि गैस मीटर सीमा पहचाि से सुसजित है, तो प्रकार मल्ू याकं ि के िौराि सही कायवप्रणाली का परीिण दकया िाएगा। (iii) अलाम,व – यदि पैरा 5 के उप-परै ा (7) के खंड (i) में ििावए अिुसार आइटम की िााँच करते समय खराबी ििव की िाती ह ै या यदि परै ा 5 के उप-पैरा (7) के खडं (ii) म ेंििावई गई जस्ट्थजतया ाँपाई िाती ह,ैं तो जिम्नजलजखत कारवर्ाई की िाएाँगी, अथावत:- (क) एक िश्ृ यमाि या श्रव्य अलामव या िोिों, िो अलामव की पुजष्ट होिे और अलामव के कारण को िबाि े तक जर्द्यमाि रहता ह;ै (ख) अलामव के िौराि जर्जिष्ट अलाम व रजिस्ट्टरों (यदि लाग ू हो) म ें पंिीकरण िारी रखिा, जिस जस्ट्थजत म ें िबार्, तापमाि, संपी़िििीलता या घित्र् के जलए जडफॉल्ट मािों का उपयोग दकया िा सकता है; और (ग) लॉग में पंिीकरण (यदि लागू हो)। (8) सॉफ्टर्ेयर,– गैस मीटर में प्रयिु सॉफ्टर्ेयर से संबंजधत आज्ञापक अपेिाए ंउपाबंध I म ेंिी गई ह।ैं 6. जिललालेख.- (1) जचह्िांकि और जिलालेख,–24 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] सभी जचह्िांकि उपयोग की जिधावठरत जस्ट्थजतयों के अंतगवत आसािी से सुपाठ्य और अजमट होिे चाजहए। मॉडल अिुमोिि िस्ट्तार्ेज में जिधावठरत जचह्िांकि के अलार्ा कोई भी जचह्िांकि भ्रम उत्पन्न िहीं करेगा। आर्रण या पहचाि प्लेट पर जिम्नजलजखत िािकारी अंदकत की िाएगी। र्ैकजल्पक रूप से, तारांकि (*) के साथ प्रस्ट्तुत जचह्िांकि को इलेक्रॉजिक संकेत उपकरण के माध्यम स ेस्ट्पष्ट और अस्ट्पष्ट तरीके से िश्ृ यमाि करिा होगा। (i) गैस मीटर के जलए साधारण लाग ूजचह्ि जिम्नािुसार होंगे (क) मॉडल अिुमोिि जचह्ि (जियमों के अिुसार); (ख) जर्जिमावता का िाम या रेडमाकव; (ग) मॉडल पििाम; (घ) गैस मीटर की सीठरयल संख्या और उसके जर्जिमावण का र्षव; (ड.) सटीकता र्गव; (च) अजधकतम प्रर्ाह िर Q = … <SI इकाई>; max (ि) न्यिू तम प्रर्ाह िर Q = … <SI इकाई>; min (ि) संक्रमण प्रर्ाह िर Q = … < एसआई इकाई> (*); t (झ) गैस तापमाि सीमा और िबार् सीमा जिसके जलए गैस मीटर की त्रुठटयााँ अजधकतम स्ट्र्ीकायव त्रुठट की सीमा के भीतर होंगी, जिसे इस प्रकार व्यि दकया िाता ह:ै t – t = … - … < एसआई इकाई> (*); min max p – p = … - … < एसआई इकाई> (*); min max (ञ) घित्र् सीमा जिसके भीतर त्रुठटयााँ अजधकतम स्ट्र्ीकायव त्रुठट की सीमाओं का अिुपालि करेंगी, इंजगत की िा सकती है, और इसे इस प्रकार व्यि दकया िाएगा: ρ = … - … <एसआई इकाई> (*) यह अंकि कायविील िबार्ों की सीमा को प्रजतस्ट्थाजपत कर सकता है िब तक दक कायविील िबार् अंकि दकसी अंतर्िवर्मवत रूपांतरण उपकरण को संिर्भवत ि करे; (ट) एचएि और एलएि आर्जृ ि आउटपुट के पल्स माि (imp/< एसआई इकाई>, pul/< एसआई इकाई>, < एसआई इकाई>/imp) (*);[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 25 ठटप्पण: पल्स माि कम स े कम िह साथवक अंकों को दिया िाता है, िब तक दक यह प्रयुि इकाई के पूणािंक गुणक या ििमलर् अंि के बराबर ि हो। (ि) र्णव V या H, िैसा लागू हो, यदि मीटर को केर्ल ऊध्र्ावधर या िैजति जस्ट्थजत में संचाजलत दकया िा सकता है; (ड) प्रर्ाह दििा का संकेत, उिाहरण के जलए एक तीर (यदि लागू हो, तो पैरा 5 के उप-परै ा (2) का खंड (i) और पैरा 5 के उप-पैरा (2) का खंड (ii) िेखें); (ढ) र्ण व M, िैसा लाग ू हो, यदि मीटर को केर्ल पाइप्पगं व्यर्स्ट्था म ें स्ट्थाजपत करि े के जलए जडजाइि दकया गया ह ै िहा ाँ केर्ल हल्के प्रर्ाह व्यर्धाि हो सकते ह;ैं (ण) परै ा 9 के उप-पैरा (1) के खंड (iv) के अिुसार कायव िबार् के जलए माप प्बंि;ु तथा (त) पयावर्रण तापमाि, यदि र्े पैरा 6 के उप-परै ा (1) खडं (i) उप-खंड (i) में उजल्लजखत गैस तापमाि से जभन्न ह ैं(*). (ii) केर्ल एक संकेतक उपकरण र्ाले अंतर्िवर्मवत रूपांतरण उपकरण र्ाल े गैस मीटरों के जलए अजतठरि जचह्िों में जिम्नजलजखत िाजमल होंगे, अथातव :- (क) आधार तापमाि t = … < एसआई इकाई> (*); b (ख) आधार िबार् p =.... < एसआई इकाई> (यदि लागू हो) (*); b (ग) तापमाि t = … < एसआई इकाई> जर्जिमावता द्वारा पैरा 4 के उप-पैरा (3) के खडं (v) के अिुसार जिर्िवष्ट दकया गया sp ह ै(*)। (iii) आउटपुट ड्राइर् िाफ्ट र्ाले गैस मीटर के जलए अजतठरि जचह्िों मे जिम्नजलजखत िाजमल होंगे, अथावत:- (क) आउटपुट ड्राइर् िाफ्ट या जडटैचेबल अजतठरि उपकरणों के संचालि के जलए अन्य सुजर्धाओं से सुसजित गैस मीटर म ें प्रत्येक ड्राइर् िाफ्ट या अन्य सुजर्धा में इसके जस्ट्थरांक (C) के संकेत के रूप म ें “1 रेर् = … < एसआई इकाई>” और रोटेिि की दििा होगी। (“रेर्” िब्ि “रेर्ोल्यिू ि”) का संजिप्त रूप ह;ै (ख) यदि केर्ल एक ड्राइर् िाफ्ट ह ै तो अजधकतम स्ट्र्ीकायव टॉकव को “M = … N. ”; के रूप म ें जचजह्ित दकया max mm िाएगा; (ग) यदि कई ड्राइर् िाफ्ट ह,ैं तो प्रत्येक िाफ्ट को “M , M , …M ”; के रूप म ें सबजस्ट्क्रप्ट के साथ M अिर द्वारा जचजह्ित 1 2 n दकया िाएगा; (घ) गैस मीटर पर जिम्नजलजखत सूत्र दिखाई िगे ा: k M + k M + … + k M ≤ A N.mm; 1 1 2 2 n n िहााँ:26 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] A उच्चतम जस्ट्थरांक के साथ ड्राइर् िाफ्ट पर लाग ू अजधकतम अिुमेय टॉकव का संख्यात्मक माि है, िहा ाँ टॉकव केर्ल इस िाफ्ट पर लाग ूहोता ह;ै इस िाफ्ट को प्रतीक M1 द्वारा जचजह्ित दकया िाएगा, k (i= 1, 2, … n) एक संख्यात्मक माि ह ैजिसे जिम्न प्रकार स ेजिधावठरत दकया िाता ह:ै ki = C1 / Ci, i M (i= 1, 2, … n) प्रतीक M द्वारा जचजह्ित ड्राइर् िाफ्ट पर लागू टॉकव ह,ै i i C (i= 1, 2, … n) प्रतीक M द्वारा जचजह्ित ड्राइर् िाफ्ट के जलए जस्ट्थरांक को ििावता Mi ह।ै i i (iv) इलेक्रॉजिक उपकरणों के साथ गैस मीटर के जलए अजतठरि जचह्िों म ेजिम्नजलजखत िाजमल होंगे, अथावत:- (क) बाहरी जबिली आपूर्तव के जलए: िाममात्र र्ोल्टेि और िाममात्र आर्ृजि; (ख) गरै -प्रजतस्ट्थापि योग्य जबिली स्रोत के जलए: मापि े र्ाल े उपकरण का पठरचालि िीर्िकाल या, र्ैकजल्पक रूप से, समय की इकाइयों में िषे बैटरी िमता को इलेक्रॉजिक संकेत उपकरण पर जर्जिर्िवष्ट दकया िा सकता है (*); (ग) बिली िा सकिे र्ाली बैटरी के जलए: बैटरी को बिलि े की अंजतम तारीख या, र्ैकजल्पक रूप स,े िषे बैटरी िमता को इलेक्रॉजिक संकेतक जडर्ाइस पर जर्जिर्िवष्ट करिा होगा (*); ठटप्पण: यदि बैटरी िीर्ि 10% से कम होिे पर स्ट्र्चाजलत अलामव संकेत िेता ह,ै तो उपरोि जचह्िों की अपेिा िहीं ह।ै (घ) िमवर्ेयर की सॉफ्टर्ेयर पहचाि (*)। 7. संचालि जििेि.– (1) जििेि पुजस्ट्तका,– िब तक मापि यंत्र की सरलता इसे अिार्श्यक ि बिा िे, प्रत्येक व्यजिगत यंत्र के साथ उपयोगकता व के जलए जिििे पुजस्ट्तका होगी। तथाजप, एक ही ग्राहक को जर्तठरत दकए िािे र्ाल े समाि मापि यंत्रों के समूहों के जलए अलग-अलग जििेि पुजस्ट्तकाओं की अपेिा िहीं होती ह।ै जििेि पुजस्ट्तका अग्रं ेिी भाषा में होगी (अग्रं ेिी भाषा के अजतठरि िेर्िागरी जलजप म ें प्हिं ी या अन्य भारतीय िेत्रीय भाषाओं का उपयोग दकया िा सकता ह)ै । मैिुअल म ेंजिम्नजलजखत िाजमल होंग,े अथावत्:- (क) संचालि जििेि; (ख) अजधकतम और न्यूितम भडं ारण तापमाि;[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 27 (ग) रेटेड संचालि जस्ट्थजतया;ं (घ) जर्द्युत िजि चालू करिे के बाि र्ामव-अप समय (यदि लागू हो); (ङ) अन्य सभी सुसंगत यांजत्रक और जर्द्युत चुम्बकीय पयावर्रणीय जस्ट्थजतया;ं (च) बाहरी जबिली स्रोत द्वारा संचाजलत उपकरणों के जलए अपेजित र्ोल्टेि (-रेंि) और आर्ृजि (-रेंि) का जर्जििेि; (ि) कोई जर्जिष्ट स्ट्थापिा ित,ें उिाहरण के जलए जसग्नल, डटे ा और जियंत्रण लाइिों की लंबाई की सीमा; (ि) यदि लाग ूहो: बैटरी के जर्जििेि; (झ) स्ट्थापिा, रखरखार्, मरम्मत, भंडारण, पठरर्हि और अिुमेय समायोिि के जलए जििेि (यह एक अलग िस्ट्तार्ेज में हो सकता ह,ै उपयोगकताव या स्ट्र्ामी के जलए अजभप्रेत िहीं ह)ै ; (ञ) इंटरिेस, उप-असेंबली (मॉड्यलू ) या अन्य माप उपकरणों के साथ संगतता के जलए ितें। (2) संस्ट्थापिा की ित,ें – जर्जिमावता जिम्नजलजखत के संबंध में संस्ट्थापिा की ित ें (िैसा लाग ूहो) जिर्िष्टव करेगा, अथावत:् - (क) गैस के कायव तापमाि को मापि े की जस्ट्थजत; (ख) दफल्टटरंग; (ग) समतलीकरण और अजभजर्न्यास; (घ) प्रर्ाह ग़िब़िी (न्यूितम अपस्ट्रीम और डाउिस्ट्रीम पाइप लंबाई सजहत); (ङ) स्ट्पंिि या ध्र्जिक हस्ट्तिेप; (च) तेज िबार् पठरर्तिव ; (ि) यांजत्रक तिार् की अिुपजस्ट्थजत (टॉकव और झुकिे के कारण); (ि) गैस मीटर के बीच पारस्ट्पठरक प्रभार्; (झ) माउंटटंग जििेि; (ञ) गैस मीटर और किेप्क्टंग पाइप कायव के बीच अजधकतम स्ट्र्ीकायव व्यास अंतर; (ट) अन्य सुसंगत स्ट्थापिा की ितें।28 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] 8. सीप्लंग.– (1) सत्यापि जचह्ि और सुरिा उपकरण,– (i) साधारण उपबंध,– मीटर के मेरोलॉजिकल गुणों की सुरिा हाडवर्ेयर (मैकेजिकल) सीप्लंग और िहा ाँ भी संभर् हो इलेक्रॉजिक सीप्लंग के माध्यम से की िाती ह।ै दकसी भी मामल े म,ें मापी गई गैस की याि की गई मात्रा (मात्रा या द्रव्यमाि) को अिजधकृत पहुचाँ को रोकि े के जलए सील दकया िाएगा। (ii) सत्यापि जचह्ि,– सत्यापि जचह्ि यह ििावते ह ैंदक गैस मीटर ि े प्रारंजभक सत्यापि सिलतापूर्वक पास कर जलया ह।ै (iii) हाडवर्ेयर सीप्लगं (यदि लागू हो),– हाडवर्ेयर सीप्लंग के मामले म,ें जचह्िों का स्ट्थाि इस तरह स े चुिा िाएगा दक इिम ें से दकसी एक जचह्ि द्वारा सील दकए गए भाग को हटाि े से इस सील को स्ट्थायी रूप से दिखाई िेि े र्ाला िुकसाि हो। सत्यापि या सुरिा जचह्िों के साथ सील दकए िाि े र्ाल ेस्ट्थाि जिम्नजलजखत उपकरण पर प्रिाि दकए िाएंग,े अथावत:् - (क) उि सभी प्लेटों पर जिि पर इस जर्जििेि द्वारा जिधावठरत िािकारी हो; ठटप्पण: यह अपिे ा केर्ल तभी अपेजित ह ैिब िेमप्लेट को मीटर से अलग दकया िा सके। (ख) केस के उि सभी भागों पर जिन्ह ें माप की सटीकता को प्रभाजर्त करिे र्ाल े हस्ट्तिेप स ेअन्यथा संरजित िहीं दकया िा सकता ह;ै तथा (ग) सील बाहरी पठरजस्ट्थजतयों का सामिा करिे म ेंसिम होंगी। (iv) इलेक्रॉजिक सीप्लगं (यदि लाग ूहो),– (क) िब माप के पठरणामों के जिधावरण में योगिाि िेिे र्ाले मापिंडों तक पहुचं को संरजित करिे की अपिे ा होती है, और इलेक्रॉजिक सीप्लगं की अिुमजत जर्जधक माप जर्ज्ञाि जिििे क द्वारा िी िाती है, तो सरु िा जिम्नजलजखत जस्ट्थजतयों को पूरा करेगी, अथावत्:- (क) केर्ल अजधकृत व्यजि को ही सुरजित साधिों िैसे कोड या पासर्डव या जर्िेष उपकरण िैसे (हाडव की,आदि) का उपयोग करके इि मापिडं ों को संिोजधत करि े के जलए कॉजन्फगरेिि मोड म ें प्रर्ेि करिे की अिुमजत होगी,–[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 29 (I) मापिंडों को बिलिे से पहले पहुचं के जलए, जिसके बाि उपकरण को जबिा दकसी प्रजतबंध के दिर स े "सीलबंि जस्ट्थजत म"ें उपयोग म ेंलाया िा सकता ह,ै या (II) मापिंडों को बिलिे के बाि पुजष्ट के जलए, उपकरण को “सीलबिं जस्ट्थजत में” (िास्त्रीय या यांजत्रक सीप्लंग के समाि) सेर्ा में र्ापस लाि े के जलए; (ख) कोड (पासर्ड)व को बिला िा सकता ह;ै (ग) उपकरण को या तो स्ट्पष्ट रूप से यह इंजगत करिा चाजहए दक यह कब कॉजन्फगरेिि मोड म ें ह ै (जर्जधक मापजर्ज्ञाि जियंत्रण के अधीि िहीं), यह इस मोड में काम िहीं करेगा। यह जस्ट्थजत तब तक बिी रहगे ी िब तक दक उपकरण को परै ाग्राि 8 के उप-पैराग्राि (1) के खंड (iv) के उप-खडं (क) के मि (क) के अिुसार "सीलबंि जस्ट्थजत म"ें उपयोग म ेंिहीं लाया िाता ह;ै (घ) सबसे हाल के हस्ट्तिपे स े संबंजधत पहचाि डेटा को इर्ेंट लॉगर में ििव दकया िाएगा। ठरकॉडव म ें कम स े कम जिम्नजलजखत िाजमल होंग,े– (I) हस्ट्तिेप को लागू करिे र्ाले अजधकृत व्यजि की पहचाि, और (II) आंतठरक घ़िी द्वारा उत्पन्न हस्ट्तिेप की घटिा काउंटर या जतजथ और समय। (ङ) उपयुवि डेटा के अलार्ा जिम्नजलजखत डेटा सग्रं हीत दकया िािा है,– (I) पठरर्र्तवत परै ामीटर का परु ािा माि; और (II) रजिस्ट्टरों का योग। सबसे हाल के हस्ट्तिेप की रेसजबजलटी सुजिजश्चत की िाएगी। यदि एक से अजधक हस्ट्तिेप के ठरकॉडव को संग्रहीत करिा संभर् ह,ै और यदि िए ठरकॉड वकी अिुमजत ििे े के जलए जपिल े हस्ट्तिेप को हटािा अपेजित है, तो सबसे परु ािा ठरकॉड व हटा दिया िाएगा। (ख) जिि गैस मीटरों के कुि भाग अलग दकए िा सकते हैं, उिके जलए जिम्नजलजखत जस्ट्थजतयों को परू ा करिा होगा, अथावत:् - (क) माप के पठरणामों के जिधावरण में योगिाि ििे े र्ाल े मापिंडों तक पहुचं जडस्ट्किेक्टेड पोटव के माध्यम से तब तक संभर् िहीं होगी िब तक दक उप-परै ा (1) के खंड (iv) की ितें परू ी ि हो िाएं; (ख) दकसी भी ऐसे उपकरण का उपयोग, िो सटीकता को प्रभाजर्त कर सकता ह,ै को इलेक्रॉजिक और डेटा प्रोसेप्संग प्रजतभूजतयों के माध्यम से या, यदि संभर् ि हो तो, मकैजिकल साधिों द्वारा रोका िाएगा; (ग) ऐसे गैस मीटरों को ऐसे प्रार्धािों से सुसजित दकया िाएगा िो मीटर को संचाजलत करि े की अिुमजत िहीं िेंगे यदि भागों को जिमावता के जर्जििेिों के अिुसार समिरूु प िहीं दकया गया है; ठटप्पण: अिजधकृत जर्योिि (िैसे दक उपयोगकताव द्वारा) को रोका िा सकता है, उिाहरण के जलए एक उपकरण के माध्यम से िो जर्योिि करि े और पिु ः िो़ििे करिे के बाि दकसी भी माप के जिष्पािि को अर्रुद् कर िेता ह।ै30 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] 9. परीिण के जलए उपयिु ता.– उपकरण को इस प्रकार जडिाइि दकया िािा चाजहए दक प्रारंजभक सत्यापि, पुिः सत्यापि तथा जिरीिण एर्ं मापजर्ज्ञाि संबंधी पयवर्ेिण दकया िा सके। (1) प्रिे र टैप्पगं ,– (i) साधारण,- यदि गैस मीटर को 0.15 MPa के पूणव िबार् से ऊपर संचाजलत करिे के जलए जडजाइि दकया गया है, तो जिमावता को या तो मीटर को प्रेिर टैप्पंग से सुसजित करिा होगा, या इंस्ट्टॉलेिि पाइप कायव म ें प्रेिर टैप्पंग की जस्ट्थजत जिर्िष्टव करिी होगी। दकसी भी मामले में उि टैप्पंग को संभाजर्त संघिि के प्रभार् से बचिे के जलए जडजाइि दकया िािा चाजहए; ठटप्पण: प्रत्यि द्रव्यमाि माप र्ाले मीटरों या अंतर्िवर्मवत िबार् सेंसर र्ाल ेमीटरों के जलए यह अपेिा आज्ञापक िहीं ह।ै (ii) बोर,– प्रेिर टैप्पगं का बोर इतिा ब़िा होिा चाजहए दक सही िबार् मापि हो सके; (iii) क्लोजर,– प्रेिर टैप्पगं को गैस-रोधी बिािे के जलए बंि करि े का साधि उपलब्ध कराया िाए; (iv) मार्किंग,– कायविील िबार् [पैरा 2 के उप-पैरा (3) के खंड (viii)] को मापिे के जलए गैस मीटर पर िबार् टैप्पंग को स्ट्पष्ट रूप से और अजमट रूप से “p ” (अथावत ् िबार् माप प्बंि)ु या “p” (अथावत ् िबार् संिभव प्बंि)ु और अन्य िबार् टैप्पंग को “p” के रूप म ें m r जचजह्ित दकया िाएगा। उपबधं I: सॉफ्टर्ये र जियजं त्रत गसै मीटर के जलए अपिे ाएं गसै मीटर (आज्ञापक) 1 साधारण अपिे ाए.ं – (1) सॉफ्टर्ये र की पहचाि,– गैस मीटर या उसके घटकों या िोिों के सॉफ्टर्ेयर के सुसंगत भागों को सॉफ्टर्ेयर संस्ट्करण या दकसी अन्य टोकि स े स्ट्पष्ट रूप से पहचािा िािा चाजहए। पहचाि कम से कम एक भाग पर लाग ूहोगी। पहचाि सॉफ्टर्ेयर स ेअजभन्न रूप से ि़िु ी होगी और इसे,– (i) आिेि पर प्रस्ट्तुत या मुदद्रत करिा होगा; या (ii) संचालि के िौराि प्रिर्िवत करिा होगा; या (iii) उि गैस मीटरों के जलए जस्ट्र्च-ऑि पर प्रिर्िवत करिा होगा जिन्ह ेंचाल ू और बंि दकया िा सकता ह।ै[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 31 यदि गैस मीटर के दकसी घटक पर कोई जडस्ट्प्ल े िहीं ह,ै तो पहचाि को संचार इंटरिेस के माध्यम स े दकसी अन्य जडर्ाइस पर भेिा िाएगा तादक र्ह उस जडर्ाइस पर प्रिर्ितव हो सके। अपर्ाि के रूप में, गैस मीटर पर सॉफ्टर्ेयर पहचाि की िाप एक स्ट्र्ीकायव समाधाि होगी यदि यह जिम्नजलजखत ितों को पूरा करती ह:ै - (क) उपयोगकताव इंटरफेस म ें जडस्ट्प्ले पर सॉफ़्टर्ेयर पहचाि के संकेत को सदक्रय करिे के जलए कोई जियंत्रण िमता िहीं ह,ै या जडस्ट्प्ल े तकिीकी रूप से एिालॉग सूचक जडर्ाइस या इलेक्रोमैकेजिकल काउंटर को दिखाए िािे र्ाल े सॉफ़्टर्ेयर की पहचाि की अिमु जत िहीं िते ा ह।ै (ख) गैस मीटर में सॉफ्टर्ेयर पहचाि संप्रेजषत करि े के जलए कोई इंटरिेस िहीं ह।ै (ग) गैस मीटर के उत्पािि के बाि सॉफ्टर्ेयर में पठरर्तवि संभर् िहीं है, या केर्ल तभी संभर् ह,ै िब हाडर्व ेयर या हाडवर्ेयर घटक को भी बिला िाए। सॉफ्टर्ेयर पहचाि और पहचाि के साधि मॉडल अिुमोिि प्रमाणपत्र में बताए िाएंगे। (2) एल्गोठरिम और कायों की सत्यता,– गैस मीटर और/या उसके घटकों के मापि एल्गोठरिम और काय वउपयुि और कायावत्मक रूप से सही होंगे। एल्गोठरिम और कायों की िांच मापजर्ज्ञाि परीिण, सॉफ्टर्ेयर परीिण या सॉफ्टर्ेयर परीिा द्वारा करिा संभर् होगा। (3) धोखाध़िी के जर्रुद् सॉफ्टर्ये र सरु िा,– सॉफ़्टर्ेयर भाग को मेमोरी जडर्ाइस को स्ट्र्ैप करके अिजधकृत संिोधि, लोप्डगं या पठरर्तविों के जर्रुद् सुरजित दकया िाएगा। यांजत्रक सीप्लंग के अलार्ा, ऑपरेटटंग जसस्ट्टम या सॉफ़्टर्ेयर लोड करिे के जर्कल्प से लैस गैस मीटर की सरु िा के जलए तकिीकी का उपयोग दकया िाएगा। उपयोगकताव इंटरिेस द्वारा केर्ल स्ट्पष्ट रूप स े प्रलेजखत कायों को ही सदक्रय करिे की अिुमजत है, जिन्ह ें इस तरह स े कायावजन्र्त दकया िाएगा दक यह धोखाध़िीपूण व उपयोग को सुजर्धाििक ि बिाए। गैस मीटर की ऐसी जर्िेषताओं को जिधावठरत करि े र्ाल े मापिडं ों को अिजधकृत संिोधि के जर्रुद् सुरजित दकया िाएगा। सत्यापि के उद्देश्य से, र्तवमाि पैरामीटर सेटटंग का प्रिििव सभं र् होगा। ठटप्पण: उपकरण-जर्जिष्ट मापिंड केर्ल उपकरण के जर्िेष पठरचालि मोड म ें समायोज्य या चयि योग्य हो सकते ह।ैं इि मापिंडों को उि मापिंडों के रूप म ें र्गीकृत दकया िा सकता ह ै जिन्ह ें सुरजित दकया िािा चाजहए (अपठरर्तविीय) और जिन्ह ें दकसी अजधकृत व्यजि द्वारा एक्सेस दकया िा सकता है (पठरर्तविीय पैरामीटर), िैसे दक उपकरण का माजलक या उत्पाि जर्क्रेता। सॉफ्टर्ेयर संरिण म ें मकैजिकल, इलेक्रॉजिक या दक्रप्टोग्रादिक साधिों या ऐस े साधिों के संयोिि द्वारा उजचत सीप्लगं िाजमल ह,ै जिससे अिजधकृत हस्ट्तिेप असंभर् या स्ट्पष्ट हो िाता ह।ै32 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (i) िॉल्ट का पता लगाि े में सहायता,– िााँच सुजर्धाओं द्वारा महत्र्पूणव िोषों का पता लगािे का काम सॉफ्टर्ेयर द्वारा दकया िाएगा। ऐसे मामले में, यह पता लगाि े र्ाला सॉफ्टर्ेयर सुसंगत मािा िाता ह।ै मॉडल अिुमोिि के जलए प्रस्ट्ततु दकए िािे र्ाले िस्ट्तार्ेज में उि जर्संगजतयों की सूची होिी चाजहए िो महत्र्पूणव िॉल्ट का कारण बि सकती ह ैं लेदकि जिन्ह ें सॉफ्टर्ेयर द्वारा पता लगाया िाएगा। िस्ट्तार्ेज में अपेजित प्रजतदक्रया के बारे म ें िािकारी िाजमल होिी चाजहए और यदि यह इसके संचालि को समझि े के जलए अपेजित है, तो पता लगाि े र्ाल े एल्गोठरिम का जर्र्रण भी िाजमल होिा चाजहए। 2 जर्जिष्ट समिरूु प के जलए अपिे ाएं.– (1) ससु गं त भागों को जिर्िष्टव करिा और अलग करिा तथा भागों के इंटरिेस जिर्िष्टव करिा,– गैस मीटर के मापजर्ज्ञाि संबंधी सुसंगत भाग, चाह े सॉफ्टर्ेयर हो या हाडवर्ेयर, गैस मीटर के अन्य भागों द्वारा अस्ट्र्ीकायव रूप से प्रभाजर्त िहीं होंगे। यह अपेिा तब लागू होती ह ै िब गैस मीटर और/या उसके घटकों में अन्य इलेक्रॉजिक उपकरणों, उपयोगकताव या मापजर्ज्ञाि रूप स ेमहत्र्पूणव भागों के बगल में अन्य सॉफ्टर्ेयर भागों के साथ संचार करि े के जलए इंटरिेस होते ह।ैं (i) गैस मीटर के घटकों का पृथक्करण,– (क) गैस मीटर के घटक िो जर्जधक माप जर्ज्ञाि से संबंजधत कायव करत े हैं, उिकी पहचाि की िाएगी, उन्ह ें स्ट्पष्ट रूप से पठरभाजषत दकया िाएगा तथा उिका िस्ट्तार्ेिीकरण दकया िाएगा और ये गैस मीटर का सुसंगत भाग बिेंगे; (ख) यह प्रिर्िवत दकया िाएगा दक घटकों के सुसंगत काय व और डेटा को इंटरिेस के माध्यम से प्राप्त आििे ों द्वारा अस्ट्र्ीकायव रूप से प्रभाजर्त िहीं दकया िा सकता ह।ै इसका अजभप्राय यह ह ैदक घटक में सभी आरंजभक कायों या डटे ा पठरर्तविों के जलए प्रत्येक कमांड का एक स्ट्पष्ट अश्यपवि ह।ै (ii) सॉफ्टर्ेयर भागों का पथृ क्करण,– (क) सभी सॉफ्टर्ेयर मॉड्यलू (प्रोग्राम, सबरूटीि, ऑब्िेक्ट, आदि) िो डेटा डोमेि सजहत जर्जधक माप जर्ज्ञाि से संबंजधत कायव करते ह,ैं उन्ह ेंगैस मीटर का जर्जधक माप जर्ज्ञाि से संबंजधत सॉफ्टर्ेयर भाग मािा िाता ह।ै इस भाग को उपाबंध I के पैरा (1) के उप-पैरा (1) में जिर्िवष्ट अिुसार पहचाि योग्य बिाया िाएगा। यदि सॉफ्टर्ेयर का पथृ क्करण सभं र् िहीं है, तो सभी सॉफ्टर्ेयर को सुसंगत मािा िाता ह।ै (ख) यदि सुसगं त सॉफ़्टर्ेयर भाग अन्य सॉफ़्टर्ेयर भागों के साथ संचार करता है, तो एक सॉफ़्टर्ेयर इंटरफेस पठरभाजषत दकया िाएगा। सभी संचार जर्िेष रूप से इस इंटरफेस के माध्यम स े दकए िाएगं े। संबंजधत सॉफ़्टर्ेयर भाग और इंटरफेस को स्ट्पष्ट रूप से प्रलेजखत दकया िािा चाजहए। सॉफ़्टर्ेयर के सभी सुसंगत फंक्िि और डेटा डोमेि का र्णवि दकया िािा चाजहए जिससे जििेिक (जर्जधक माप जर्ज्ञाि) यह तय कर सकें दक यह सॉफ़्टर्ेयर पयावप्त रूप से अलग ह ैया िहीं।[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 33 इंटरिेस म ें प्रोग्राम कोड और समर्पवत डेटा डोमेि िाजमल ह।ैं पठरभाजषत कोडेड कमांड या डेटा को सॉफ्टर्ेयर भागों के बीच एक सॉफ्टर्ेयर भाग द्वारा समर्पवत डेटा डोमेि में संग्रहीत करके और िसू रे द्वारा इसे पढ़कर आिाि-प्रिाि दकया िािा ह।ै प्रोग्राम कोड जलखिा और पढ़िा सॉफ्टर्ेयर इंटरिेस का भाग मािा िाता ह।ै सॉफ्टर्ेयर इंटरफेस बिािे र्ाले डेटा डोमेि को स्ट्पष्ट रूप से पठरभाजषत और प्रलेजखत दकया िािा चाजहए और इसमें र्ह कोड िाजमल होिा चाजहए िो दकसी सुसंगत भाग से इंटरफेस में जियावत करता ह ैऔर र्ह कोड िो इंटरफेस स ेसुसंगत भाग में आयात करता ह।ै घोजषत सॉफ्टर्ेयर इंटरफेस को िरदकिार िहीं दकया िाएगा। जर्जिमावता को इि बाधाओं का सम्माि करते हुए उपरोि ितों का अिुपालि सुजिजश्चत करिा होगा। दकसी प्रोग्राम को इंटरफेस को िरदकिार करिे या जिपे हुए कमांड को प्रोग्राम करिे से रोकि े के तकिीकी साधि (िैसे सीप्लगं ) संभर् िहीं होंगे। सॉफ़्टर्ेयर भाग के प्रोग्रामर को जर्जिमावता द्वारा इि अपेिाओं स ेसंबंजधत जििेि प्रिाि दकए िाएंगे। (ग) सॉफ़्टर्ेयर के संबंजधत भाग में सभी आरंजभक कायों या डटे ा पठरर्तविों के जलए प्रत्येक कमांड का एक स्ट्पष्ट असाइिमेंट होिा चाजहए। सॉफ़्टर्ेयर इंटरफेस के माध्यम स े संचार करि े र्ाल े कमांड घोजषत और प्रलेजखत दकए िाि े चाजहए। केर्ल प्रलेजखत कमांड को ही सॉफ़्टर्ेयर इंटरफेस के माध्यम स े सदक्रय करि े की अिमु जत ह।ै जर्जिमावता कमांड के िस्ट्तार्ेजीकरण की पूणवता को बताएगा। (घ) िहां जर्जधक मापजर्ज्ञाि स े संबंजधत सॉफ्टर्ेयर को गैर-प्रासंजगक सॉफ्टर्ेयर स े अलग दकया गया ह,ै र्हां जर्जधक मापजर्ज्ञाि से संबंजधत सॉफ्टर्ेयर को गरै -सुसंगत सॉफ्टर्ेयर की तुलिा में संसाधिों का उपयोग करिे म ें प्राथजमकता िी िाएगी। माप कायव (जर्जधक मापजर्ज्ञाि से संबंजधत सॉफ्टर्ेयर भाग द्वारा दकया गया) अन्य कायों द्वारा जर्लंजबत या अर्रुद् िहीं होिा चाजहए। जर्जिमावता को इि ितों का अिुपालि सुजिजश्चत करिा होगा। गैर-प्रासंजगक प्रोग्राम को सुसंगत कायों में बाधा डालिे स े रोकिे के जलए तकिीकी साधि उपलब्ध कराए िाएंगे। संबजं धत सॉफ्टर्ेयर भाग के प्रोग्रामर के साथ-साथ जर्जधक माप जर्ज्ञाि गैर-सुसंगत भाग के प्रोग्रामर को जिमावता द्वारा इि अपेिाओं से संबंजधत जििेि प्रिाि दकए िाएंगे। (2) साझा सकं ेत,– जर्जधक माप-पद्जत के जलए सॉफ्टर्ेयर के सुसंगत भाग तथा अन्य िािकारी प्रस्ट्तुत करि े के जलए एक जडस्ट्प्ल े का उपयोग दकया िाएगा। मापि मािों और अन्य सुसंगत िािकारी का संकेत िेि े र्ाला सॉफ्टर्ेयर सुसंगत भाग का गिि करेगा। (3) सचं ार प्रणाजलयों के माध्यम स ेडेटा का सग्रं ह और पारेषण,– यदि माप के मािों का उपयोग माप के स्ट्थाि से अलग दकसी स्ट्थाि पर या माप के समय से बाि में दकया िाता है, तो उन्ह ें गैस मीटर से प्राप्त करिे और उपयोग करि े से पहले असुरजित र्ातार्रण में संग्रहीत या प्रेजषत करिे की अपेिा हो सकती ह।ै ऐसे मामले म ेंजिम्नजलजखत ितें लाग ूहोंगी, अथावत्:- (i) संग्रहीत या प्रेजषत माप मूल्य के साथ भजर्ष्य म ेंउपयोग के जलए अपेजित सभी सुसंगत िािकारी संलग्न होिी चाजहए;34 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (ii) माप के समय से संबंजधत िािकारी की प्रामाजणकता, अखडं ता और, यदि अपेजित हो, तो िुद्ता की गारंटी िेि े के जलए डेटा को सॉफ्टर्ेयर के माध्यम से संरजित दकया िाएगा। माप मूल्यों और साथ के डेटा को प्रिर्िवत या आग े संसाजधत करि े र्ाला सॉफ्टर्ेयर असुरजित स्ट्टोरेि से उन्ह ें पढ़िे के बाि या असुरजित पारेषण चिै ल से उन्ह ें प्राप्त करिे के बाि डेटा के माप, प्रामाजणकता और अखडं ता का समय िांचेगा। मेमोरी जडर्ाइस में िांच सुजर्धा होिी चाजहए तादक यह सुजिजश्चत दकया िा सके दक यदि कोई अजियजमतता पाई िाती है, तो डेटा को हटा दिया िाएगा या अिुपयोगी के रूप म ेंजचजह्ित दकया िाएगा। सॉफ्टर्ेयर मॉड्यूल िो भंडारण या भेििे के जलए डेटा तैयार करते हैं, या पढ़ि े या प्राप्त करि े के बाि डेटा की िांच करत े हैं, उन्ह ेंसॉफ्टर्ेयर का भाग मािा िाता ह।ै (iii) ओपि िेटर्कव के माध्यम से मापि मािों को स्ट्थािांतठरत करत े समय, दक्रप्टोग्रादिक जर्जधयों को लाग ू करिा अपेजित होगा। इस उद्देश्य के जलए उपयोग दकए िािे र्ाल े गोपिीयता की-कोड को मापि े र्ाले उपकरणों, इलक्े रॉजिक उपकरणों या िाजमल उप-संयोििों में गप्तु और सरु जित रखा िािा चाजहए। सुरिा साधि प्रिाि दकए िािे चाजहए जिससे इि की को केर्ल तभी इिपुट या पढ़ा िा सके िब सील टूटी हो। (iv) पारेषण में जर्लंब,– मापि रांसजमिि में जर्लंब से प्रभाजर्त िहीं होगा। (v) पारेषण म ेंरुकार्ट,– यदि संचार िेटर्कव सेर्ाएं अिुपलब्ध हो िाती ह,ैं तो कोई माप डेटा िष्ट िहीं होगा। माप डेटा की हाजि को रोका िाएगा। (4) स्ट्र्चाजलत सग्रं ह,– िब अिुप्रयोग पर जर्चार करत े हुए, डेटा संग्रहण की अपिे ा होती है, तो माप डेटा स्ट्र्चाजलत रूप से संग्रजहत दकया िािा चाजहए, अथातव िब अंजतम माि सृजित हो गया हो। संग्रहण जडर्ाइस म ें पयावप्त स्ट्थाजयत्र् होिा चाजहए, जिससे यह सुजिजश्चत हो सके दक साधारण संग्रहण जस्ट्थजतयों म ें डेटा िष्ट ि हो। दकसी जर्िेष प्रयोग के जलए पयावप्त मेमोरी स्ट्टोरेि होिी चाजहए। गणिा के जलए अपेजि सभी डेटा अंजतम मल्ू य के साथ स्ट्र्चाजलत रूप से सग्रं हीत कर जलए िाएंगे। (5) डेटा का लोप करिा,– हस्ट्तांतरण के बाि संग्रहीत डेटा का लोप िा सकता ह।ै केर्ल जिपटाए गए लेिििे के जलए और यदि क्रजमक डेटा के भंडारण के जलए अपयावप्त मेमोरी िमता उपलब्ध है, तो जिम्नजलजखत ितों की पूर्तव के अधीि याि दकए गए डेटा का लोप की अिुमजत है, अथावत: - (क) डेटा को हटािे का क्रम ठरकॉर्डगिं क्रम के समाि होगा और जर्िेष अिुप्रयोग के जलए स्ट्थाजपत जियमों के अिुसार होगा;[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 35 (ख) अपेजित जर्लोपि या तो स्ट्र्चाजलत रूप स ेया जर्जिष्ट मैन्युअल ऑपरेिि के बाि िरूु हो िाएगा। 3 रखरखार् और पिु ः समिरूु प.– सेर्ा में लगे गैस मीटर के सॉफ्टर्ेयर को अद्यति करिा इस प्रकार मािा िाएगा,- (क) सॉफ्टर्ेयर को दकसी अन्य स्ट्र्ीकृत संस्ट्करण के साथ बिलते समय गैस मीटर में संिोधि; (ख) उसी संस्ट्करण को पुिः इंस्ट्टॉल करते समय गैस मीटर की मरम्मत। सेर्ा के िौराि संिोजधत या मरम्मत दकय े गय ेगैस मीटर का पिु ः सत्यापि आर्श्यक होगा। यह खंड ऐस े सॉफ्टर्ेयर पर लागू िहीं ह ै जिसका गैस मीटर के मापजर्ज्ञाि सुसंगत कायों या कायवप्रणाली पर कोई प्रभार् िहीं प़िता ह ैया िहीं प़िगे ा। भाग 2 मापजर्ज्ञाि जियत्रं ण और प्रिििव परीिण 10. मापजर्ज्ञाि जियत्रं ण.– (1) साधारण प्रदक्रयाएं,– (i) पठरिण जर्जध,– सभी परीिण परीिण दकए िािे र्ाल े मीटर के प्रकार के आपूर्तवकता व द्वारा जिधावठरत इंस्ट्टॉलेिि जस्ट्थजतयों (मीटर के अपस्ट्रीम और डाउिस्ट्रीम में पाइप्पंग के सीधे खंड, प्रर्ाह कंडीििर, आदि) के अधीि दकए िाएंगे। परीिण प्रदक्रया के जिष्पािि के भाग के रूप में उपयोग दकए गए और िाजमल दकए गए सभी उपकरण परीिण के अधीि मीटर के परीिण के जलए उपयुि होंगे। सभी उपकरणों और संिभव मािकों की कायव सीमा परीिण के अधीि मीटर के बराबर या उससे अजधक होगी। उपयोग दकए गए सभी संिभव मािक, माप के राष्ट्रीय या अंतरावष्ट्रीय मािकों के अिुसार होि े चाजहए। यदि मीटरों का परीिण श्रृंखला में दकया िािा ह,ै तो मीटरों के बीच कोई महत्र्पणू व अंतःदक्रया िहीं होिी चाजहए। इस जस्ट्थजत को श्रृंखला के प्रत्येक मीटर का लाइि म ेंप्रत्येक स्ट्थाि पर एक बार परीिण करके सत्याजपत दकया िा सकता ह।ै परीिणों के िौराि, परीिण और संिभव मािक के अधीि मीटरों के बीच तापमाि और िबार् के अंतर के जलए संिोधि दकए िाएंगे; अन्यथा इि अतं रों को अजिजश्चतता गणिाओं में ध्याि में रखिा होगा। तापमाि और िबार् माप परीिण के अधीि मीटर और संिभव मािक पर एक प्रजतजिजध जस्ट्थजत में दकया िािा चाजहए। (ii) अजिजश्चतता,– िब परीिण दकया िाता ह,ै तो मापी गई गैस मात्रा की त्रुठटयों के जिधावरण की जर्स्ट्ताठरत अजिजश्चतता जिम्नजलजखत जर्जििेिों को पूरा करेगी, अथातव ् (क) मॉडल अिुमोिि के जलए : लागू MPE के पांचर्ें भाग स ेकम; (ख) सत्यापि के जलए : लागू MPE के तीसरे भाग से कम36 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] तथाजप, यदि उपयुवि माििडं परू े िहीं दकए िा सकते ह,ैं तो लागू होिे र्ाली अजधकतम स्ट्र्ीकायव त्रुठटयों को अजिजश्चतताओं की अजधकता के साथ कम करके परीिण के पठरणामों को र्कै जल्पक रूप से अिुमोदित दकया िा सकता ह।ै इस मामले में जिम्नजलजखत स्ट्र्ीकृजत माििडं ों का उपयोग दकया िाएगा, अथातव ्: (क) मॉडल अिुमोिि के जलए : ± ( ⋅MPE −U) (ख) सत्यापि के जलए : ± ( ⋅MPE −U) िब U≤ MPE जर्स्ट्ताठरत अजिजश्चतता U का अिुमाि लगभग 95% के जर्श्वास स्ट्तर के साथ लगाया गया ह।ै उिाहरण: िब यह मािा िाए दक सटीकता र्गव 1 गैस मीटर के मॉडल अिुमोिि के जलए परीिण के िौराि परीिण पठरणाम में जर्स्ट्ताठरत अजिजश्चतता U, 0.3% (k = 2) ह,ै तो त्रुठट ± (6/5 × 1.0 - 0.3)% = ± 0.9% के बीच होिे पर परीिण पठरणाम स्ट्र्ीकार दकए िा सकते ह।ैं 11. प्रकार मल्ू याकं ि.– (1) साधारण,– मूल्यांकि के जलए प्रस्ट्ततु दकया गया गैस मीटर मॉडल अिुमोिि प्रदक्रया के अधीि होता ह।ै मॉडल अिुमोिि प्रमाणपत्र द्वारा कर्र िहीं दकए गए दकसी भी अिुमोदित प्रकार म ें कोई भी संिोधि होि े पर उस प्रकार का पुिमूवल्यांकि करिा होगा। गैस मीटर का कैलकुलेटर (सकं ेतक उपकरण सजहत) और मापिे र्ाला रांसड्यूसर (प्रर्ाह, आयति या द्रव्यमाि सेंसर सजहत), िो समाि या अलग जडजाइि के अन्य कैलकुलेटर और मापिे र्ाल े रांसड्यूसर के साथ अलग-अलग और जर्जिमेय दकए िा सकते ह,ैं इि भागों का अलग-अलग प्रकार में मल्ू यांकि दकया िा सकता ह।ै मॉडल अिुमोिि प्रमाणपत्र केर्ल संपणू व गैस मीटर के जलए िारी करिा होगा। (2) िस्ट्तार्जे ीकरण,– (i) गैस मीटर के मॉडल अिुमोिि के जलए आर्ेिि के साथ जिम्नजलजखत िस्ट्तार्ेि संलग्न दकए िािे चाजहए, अथावत:् - (क) प्रकार की पहचाि, जिसमें िाजमल ह,ै– (I) जिमावता का िाम या रेडमाकव और प्रकार पििाम; (II) हाडवर्ेयर और सॉफ्टर्ेयर का संस्ट्करण; (III) िाम प्लेट का जचत्रण। (ख) मीटर की मापजर्ज्ञाि जर्िषे ताएं, जििम ेंिाजमल ह,ैं – (I) माप के जसद्ांतों का जर्र्रण;[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 37 (II) सटीकता र्गव और रेटेड पठरचालि जस्ट्थजतयों िैसे मापजर्ज्ञाि जर्जििेि; (III) मीटर का परीिण करि े से पहल े दकए िाि े र्ाले कोई भी चरण। (ग) मीटर के जलए तकिीकी जर्जििेि, जिसमें िाजमल ह,ैं– (I) घटकों और उपकरणों के कायावत्मक जर्र्रण के साथ एक ब्लॉक आरेख; (II) इंटरलॉक सजहत जिमावण और संचालि की व्याख्या करिे र्ाले जचत्र, आरेख और साधारण सॉफ्टर्ेयर िािकारी; (III) सील या सुरिा के अन्य साधिों का जर्र्रण और जस्ट्थजत; (IV) स्ट्थाजयत्र् जर्िेषताओं स ेसंबंजधत िस्ट्तार्ेि; (V) जिर्िष्टव घ़िी आर्ृजि; (VI) कोई भी िस्ट्तार्ेज या अन्य साक्ष्य िो इस धारणा का समथवि करता ह ै दक मीटर का जडजाइि और जिमावण अपेिाओं का अिुपालि करता ह।ै (घ) उपयोगकताव मैन्यअु ल; (ङ) अर्स्ट्थापि मैन्यअु ल; (च) यदि लाग ूहो तो महत्र्पूणव िॉल्ट को रोकिे के जलए िांच सुजर्धाओं का जर्र्रण। (ii) इसके अजतठरि, यदि सॉफ्टर्ेयर उपयोग म ेंह ैतो िस्ट्तार्ेि म ेंजिम्नजलजखत िाजमल होंगे,- (क) सुसंगत सॉफ़्टर्ेयर का जर्र्रण और अपिे ाओं को कैस ेपूरा दकया िाता है, जिसमें िाजमल ह,ैं– (I) सुसंगत भाग से संबंजधत सॉफ्टर्ेयर मॉड्यलू ों की सूची, जिसमें यह घोषणा भी िाजमल ह ै दक जर्र्रण म ें सभी सुसंगत कृत्य िाजमल ह;ैं (II) सुसंगत सॉफ्टर्ेयर भाग के सॉफ्टर्ेयर इंटरिेस का जर्र्रण और इस इंटरिेस के माध्यम स े कमांड और डेटा प्रर्ाह का जर्र्रण जिसमें पणू वता का जर्र्रण भी िाजमल ह;ै (III) सॉफ्टर्ेयर पहचाि के संस्ट्करण का जर्र्रण; (IV) चुिी गई सत्यापि जर्जध के आधार पर: सोसव कोड; (V) सरं जित दकए िाि े र्ाल ेमापिंडों की सूची और सुरिा साधिों का जर्र्रण; (ख) उपयिु हाडवर्ेयर जसस्ट्टम कॉजन्िगरेिि का जर्र्रण और सॉफ्टर्ेयर को इजछित रूप से संचाजलत करिे के जलए न्यिू तम अपेजित संसाधिों का जर्र्रण; (ग) ऑपरेटटंग जसस्ट्टम म ेंप्रर्ेि करिे से बचि े के जलए सुरिा साधिों का जर्र्रण (पासर्डव, आदि यदि लाग ूहो); (घ) सॉफ्टर्ेयर सीप्लंग जर्जधयों का जर्र्रण; (ङ) जसस्ट्टम हाडवर्ेयर का अर्लोकि, िैसे टोपोलॉिी ब्लॉक आरेख, कंप्यूटर का प्रकार, िेटर्कव का प्रकार, आदि;38 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (च) उि हाडवर्ेयर घटकों की पहचाि िो सुसंगत कायव करत ेहैं; (ि) एल्गोठरिम की सटीकता का जर्र्रण (उिाहरण के जलए A/D रूपांतरण पठरणामों की दिल्टटरंग, मल्ू य गणिा, राउंप्डंग एल्गोठरिम, आदि); (ि) उपयोगकताव इंटरिेस, मेिू और संर्ािों का जर्र्रण; (झ) सॉफ्टर्ेयर की पहचाि और उपयोग म ेंआि े र्ाल ेउपकरण से यह पहचाि प्राप्त करिे के जििेि; (ञ) मापि उपकरण (या उसके घटकों) के प्रत्येक हाडवर्ेयर इंटरिेस के कमाडं की सूची जिसमें पूणतव ा का जर्र्रण िाजमल ह;ै (ट) संभाजर्त महत्र्पूण व त्रुठटयों की सूची जिन्ह ें सॉफ्टर्ेयर द्वारा पता लगाया िाएगा और उि पर कारवर्ाई की िाएगी और यदि समझिे के जलए अपेजित हो, तो पता लगािे र्ाले एल्गोठरिम का जर्र्रण; (ि) संग्रहीत या रांसजमट दकए गए डेटा सेट का जर्र्रण; (ड) यदि सॉफ्टर्ेयर म ें िॉल्ट का पता लगाया िाता है, तो पता लगाए गए िॉल्ट की एक सूची और पता लगाि े र्ाले एल्गोठरिम का जर्र्रण; (ढ़) ऑपरेटटंग मैिुअल। (3) जडजाइि जिरीिण,– प्रस्ट्तुत दकए गए प्रत्येक प्रकार के गैस मीटर का बाहरी जिरीिण दकया िाएगा, जिससे यह सुजिजश्चत दकया िा सके दक यह इि अपेिाओं के सुसंगत पूर्वर्ती खंडों के उपबंधों का अिुपालि करता ह।ै (4) िमिू ों की सख्ं या,– आर्ेिक को, प्रकार के अिरूु प जिर्मवत गैस मीटरों के िमूिों की अिुरोजधत संख्या, प्रकार मूल्याकं ि के जलए जिििे क (जर्जधक माप जर्ज्ञाि) के पास िमा करािी होगी। यदि प्रकार मूल्यांकि के जलए जिम्मेिार जििेिक (जर्जधक माप जर्ज्ञाि) द्वारा ऐसा अिुरोध दकया िाता है, तो इि मीटरों म ें एक से अजधक आकार (अजधमाितः सभी आकार) िाजमल होंगे, यदि गैस मीटरों के एक पठरर्ार के एक साथ अिुमोिि का अिुरोध दकया िाता ह ै(िेखें उपाबंध घ: गैस मीटरों के एक पठरर्ार का मॉडल अिुमोिि)। परीिणों के पठरणामों के आधार पर, मॉडल अिुमोिि के जलए जिम्मेिार जििेिक (जर्जधक माप जर्ज्ञाि) अजतठरि िमूिों का अिुरोध कर सकते ह।ैं[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 39 परीिण प्रदक्रया में तेिी लाि े के जलए, परीिण प्रयोगिाला जर्जभन्न इकाइयों पर एक साथ जर्जभन्न परीिण कर सकती ह।ै इस मामले म,ें परीिण प्रयोगिाला यह सुजिजश्चत करेगी दक सभी प्रस्ट्तुत उपकरण एक ही प्रकार के हों। साधारणतया सभी सटीकता और प्रभार् परीिण एक ही इकाई पर दकए िाएंगे, लेदकि अजतठरि उपकरणों पर ग़िब़िी परीिण दकए िा सकत े ह।ैं इस मामले में, परीिण प्रयोगिाला यह तय करती ह ैदक दकस इकाई पर कौि सा परीिण दकया िािा ह।ै यदि कोई िमूिा दकसी जर्जिष्ट परीिण म ें पास िहीं होता ह ै और पठरणामस्ट्र्रूप उस े संिोजधत या मरम्मत करि े की अपेिा होती ह,ै तो आर्ेिक परीिण के जलए प्रस्ट्ततु सभी िमूिों पर यह संिोधि लाग ू करेगा। इि संिोजधत िमिू ों को दिर से इस जर्िेष परीिण के अधीि दकया िाएगा। यदि परीिण प्रयोगिाला के पास यह माििे के जलए िोस कारण ह ैं दक संिोधि का दकसी अन्य परीिण या पहले स े दकए गए परीिणों के पठरणाम पर िकारात्मक प्रभार् प़ि सकता है, तो इि परीिणों को भी िोहराया िाएगा। (5) मॉडल अिमु ोिि प्रदक्रया,– (i) सॉफ्टर्ेयर मूल्यांकि,– सॉफ्टर्ेयर मूल्यांकि प्रदक्रया, भाग 1 उपाबधं I म ें र्र्णवत अपेिाओं के अिुपालि के मूल्याकं ि से संबंजधत ह ै और इसमें जर्श्लेषण और सत्यापि जर्जधयों और परीिणों का संयोिि िाजमल है, िैसा दक सारणी 6 में दिखाया गया ह।ै प्रयिु संजिप्तीकरणों का स्ट्पष्टीकरण और जर्जधयों से संबंध, िैसा दक जर्स्ट्तार स ेर्र्णवत ह,ै सारणी 7 में दिखाया गया ह।ै सारणी 6. अिुपालि के सत्यापि के जलए लाग ूसॉफ्टर्ेयर सत्यापि प्रदक्रयाएं क्रम अपिे ाएं मल्ू याकं ि प्रदक्रया सं. (1) (2) (3) (4) (क) उपाबंध I के पैरा.1 का उप- सॉफ्टर्ेयर पहचाि AD + VFTSw पैरा (1) (ख) उपाबंध I के पैरा.1 का उप- एल्गोठरिम की सत्यता AD + VFTSw पैरा (2) (ग) उपाबंध I के पैरा.1 का उप- कपट से सुरिा AD + VFTSw + DFA/CIWT/SMT1 पैरा (3) (घ) पैरामीटर सुरिा AD + VFTSw + DFA/CIWT/SMT1 (ङ) उपाबंध I के पैरा.2 का उप- इलेक्रॉजिक उपकरणों और उप- AD पैरा (1) असेंबली का पथृ क्करण (च) उपाबंध I के पैरा.2 का उप- सॉफ्टर्ेयर भागों का पृथक्करण AD पैरा (2) (ि) उपाबंध I के परै ा.2 का (3) डेटा का सग्रं हण, संचार प्रणाजलयों AD + VFTSw + CIWT/SMT1 के माध्यम से रांसजमिि (ि) उपाबंध I के पैरा. 2 के उप- माप के समय के संबंध म ें डेटा AD + VFTSw + SMT1 पैरा (3) का खंड (i) सुरिा (झ) उपाबंध I के पैरा.2 का उप- स्ट्र्चाजलत संग्रहण AD + VFTSw पैरा (4) (ञ) उपाबंध I के पैरा .2 के उप- रांसजमिि में जर्लंब AD + VFTSw40 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] पैरा (3) का खंड (iv) (ट) उपाबंध I के परै ा.2 के उप- रांसजमिि में रुकार्ट AD + VFTSw पैरा (3) का खंड (v) (ि) टाइम स्ट्टैंप AD + VFTSw सारणी 7. उपाबंध ड. में र्र्णतव मूल्यांकि प्रदक्रयाओं के क्रॉस संिभव क्रम सजं िप्त रूप जर्र्रण सबं जं धत उपाबधं ञ सं. (1) (2) (3) (4) (क) AD िस्ट्तार्ेजीकरण का जर्श्लेषण और जडजाइि का उपाबंध ङ (ङ1) सत्यापि (ख) VFTM मापजर्ज्ञाि िंक्िि के कायावत्मक परीिण द्वारा उपाबंध ङ (ङ2) सत्यापि (ग) VFTSw सॉफ्टर्ेयर िंक्िि के कायावत्मक परीिण द्वारा उपाबंध ङ (ङ3) सत्यापि (घ) DFA1 मापजर्ज्ञाि डेटा प्रर्ाह जर्श्लेषण उपाबंध ङ (ङ4) (ङ) CIWT1 कोड जिरीिण और र्ॉकथ्र ू उपाबंध ङ (ङ5) (च) SMT1 सॉफ्टर्ेयर मॉड्यलू परीिण उपाबंध ङ (ङ6) (1) यदि िीचे दिए गए तीि प्रकरणों में से कोई एक लागू होता है, तो मल्ू यांकि जर्जधयों डीएिए, सीआईडब्ल्यूटी और एसएमटी का जिष्पािि अपेजित िहीं ह:ै मामला 1: गैस मीटर म ेंकोई डटे ा रांसजमिि इंटरिेस िाजमल िहीं है, या मामला 2: एक रांसजमिि इंटरिेस िाजमल दकया गया ह ै लेदकि यह केर्ल गैस मीटर से माप डेटा आउटपुट प्रिाि करता ह,ै या मामला 3: ओपि जसस्ट्टम में मापि डेटा का रांसजमिि संभर् िहीं ह।ै (ii) हाडवर्ेयर मूल्यांकि,– (क) संिभ वित,ें – परीिण की िा रही प्रभाजर्त करिे र्ाली मात्रा को िो़िकर सभी प्रभाजर्त करिे र्ाली मात्राओं को गैस मीटर पर मॉडल अिुमोिि परीिणों के िौराि जिम्नजलजखत मािों पर रखा िाएगा: र्र्किंग (गैस/र्ायु) तापमाि: (20.0 ± 5.0) °C; पठरर्ेि का तापमाि: (20.0 ± 5.0) °C;[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 41 पठरर्ेिी र्ायुमंडलीय िबार्: 86 kPa – 106 kPa; पठरर्ेि सापेि आद्रवता: 60 % ± 25 %; पार्र र्ोल्टेि (एसी/डीसी मेन्स): * यदि एक िॉजमिल र्ोल्टेि जिर्िवष्ट की गई ह:ै यह जिर्िवष्ट िॉजमिल र्ोल्टेि (U ); nom * यदि र्ोल्टेि रेंि जिर्िवष्ट ह:ै इस सीमा के भीतर एक जर्जिष्ट र्ोल्टेि, जिस पर जर्जिमावता और परीिण प्रयोगिाला के बीच बातचीत की िाएगी; पार्र र्ोल्टेि (बैटरी): एक िई या परू ी तरह से चािव की गई बैटरी का िॉजमिल र्ोल्टेि (चािव के अंतगवत िहीं); पार्र फ्रीिेंसी (एसी मन्े स): िॉजमिल फ्रीिेंसी (f ) nom ठटप्पण: उच्च िबार् परीिण संिभव जस्ट्थजतयों के अलार्ा अन्य जस्ट्थजतयों में भी दकया िा सकता ह।ै (ख) फ्लो रेट,– फ्लो रेट, जिस पर गैस मीटरों की त्रुठटयों को जिधावठरत करिे की अपेिा है, को जियजमत अंतराल पर माप सीमा में जर्तठरत दकया िाएगा और इसमें Q और Q और आिि व रूप से Q िाजमल होंगे। min max t प्रजत ििक तीि परीिण प्बंिओंु के आधार पर परीिण प्बंिओंु की न्यूितम संख्या (N), i= 1 स े i= N तक की रैंककंग की गणिा जिम्न के अिुसार की िा सकती ह:ै N = 1+3. Log िहााँ N ≥ 6, और जिकटतम पणू ािंक तक पूणािंदकत दकया िाता ह।ै िो ििक या उससे अजधक अर्जध के फ्लो रेट के जलए जिम्नजलजखत सूत्र i= 1 से i= N–1 और Q = Q के जलए फ्लो रेट N min का पयावप्त जियजमत जर्तरण प्रस्ट्तुत करता ह।ै Q= ( )1-i.Q i max (ग) परीिण के जलए गैसें,– (I) मॉडल अिुमोिि परीिणों के जलए अपेजित गैस ें पैरा 11 के उप-परै ा (6) म ें सूचीबद् सभी परीिण हर्ा या पैरा 4 उप-पैरा (1) में बताई गई रेटेड पठरचालि जस्ट्थजतयों के अधीि जर्जिमावता द्वारा जिर्िष्टव दकसी अन्य गैस के साथ दकए िा सकते ह।ैं पैरा 11 उप-परै ा (6) के खंड (vii) में तापमाि परीिणों के जलए यह महत्र्पूण व ह ैदक गैस सूखी हो।42 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] जर्जभन्न गैसों को मापि े के जलए अजभप्रेत गैस मीटरों (िैसा दक पैरा 11 के उप-परै ा (6) के खडं (xii) म ें बताया गया ह)ै का परीिण जर्जिमावता द्वारा जिर्िष्टव गैसों के साथ दकया िािा चाजहए। (II) सत्यापि के िौराि र्ैकजल्पक परीिण गैस के उपयोग का मूल्यांकि,– िब गैस मीटरों को (प्रारंजभक या पुिः सत्यापि पर) र्ायु के साथ सत्याजपत दकया िािा हो, तो परै ा 11 के उप-परै ा (6) का खंड (xiii) में बताए गए मॉडल अिुमोिि परीिण में र्ायु िाजमल होगी। िब गैस मीटरों को पठरचालि जस्ट्थजतयों से जभन्न दकसी गैस के प्रकार के साथ सत्याजपत दकया िािा हो, तो परै ा 11 के उप- पैरा (6) का खंड (iii) में बताए गए मॉडल अिुमोिि परीिण में उस प्रकार की गैस िाजमल होगी। उपरोि िोिों मामलों म ें इजछित परीिण गैस और उपयोग की िािे र्ाली गैस के त्रुठट र्क्रों के बीच अजधकतम अंतर की गणिा की िाती ह ै और सत्यापि परीिण के िौराि सुधार कारकों का उपयोग करि े की अपिे ा (परै ा 12 के उप-परै ा (1) के खंड (iv) का उप-खडं (ग) िखे ें) जिम्नािुसार स्ट्थाजपत की िाती ह:ै (क) यदि ये अतं र 1/3 एमपीई के भीतर रहते ह,ैं तो र्ैकजल्पक गैस के साथ प्रारंजभक त्रुठट-सत्यापि दकया िा सकता ह।ै (ख) यदि ये अंतर 1/3 एमपीई से अजधक ह,ैं तो र्ैकजल्पक गैस के साथ प्रारंजभक या पुिः सत्यापि तभी दकया िाएगा, िब अंतरों के जलए सुधार लागू दकया गया हो। मॉडल अिुमोिि के जलए जिम्मेिार जििेिक (जर्जधक माप जर्ज्ञाि) यह िस्ट्तार्ेि तैयार करेगा दक क्या प्रारंजभक या पुिः सत्यापि हर्ा [या अन्य गैसों] के साथ दकया िा सकता ह ैऔर क्या सुधार कारक लाग ूदकए िािे चाजहए। (6) मॉडल अिमु ोिि परीिण,– मॉडल अिुमोिि के िौराि गैस मीटरों का परीिण परै ा 4 में बताई गई अपेिाओं को लाग ूकरते हुए दकया िाता ह।ै उपाबंध ग जर्जभन्न माप जसद्ांतों के जलए अपेजित परीिणों का अर्लोकि दिखाता ह।ै (i) त्रुठटया,ं – गैस मीटर की त्रुठट का जिधावरण, पैरा 11 के उप-पैरा (5) के खडं (ii) का उप-खडं (ख) में बताए गए जििेिों के अिुसार फ्लो रेट का उपयोग करत े हुए दकया िाएगा। त्रुठट र्क्र और साथ ही डब्ल्यूएमई [ पैरा 2 के उप-परै ा (2) के खडं (v)] क्रमिः परै ा 4 का उप-परै ा (3) और परै ा 4 का उप-पैरा (4) म ेंजिर्िवष्ट अपिे ाओं के अिुसार होंगे। यदि प्रेिणों से र्क्र दिट बिाया िाता ह,ै तो न्यूितम 6 जडग्री स्ट्र्तंत्रता की अपेिा होती ह।ै ठटप्पण: प्रेिणों की संख्या और र्क्र दिट के जलए अपेजित मापिंडों या गणु ांकों की संख्या के बीच का अतं रे स्ट्र्तंत्रता की जडग्री की संख्या होता ह।ै उिाहरण के जलए, यदि 4 गुणांकों के साथ एक बहुपि र्क्र दिटटंग का उपयोग दकया िाता है, तो न्यूितम 6 जडग्री स्ट्र्तंत्रता प्राप्त करिे के जलए कम से कम 10 माप प्बंि ुअपेजित ह।ैं गैस मीटर पर लागू सटीकता परीिण के िौराि, जिम्नजलजखत मात्राएं जिधावठरत की िाएंगी,– (क) यदि लाग ूहो, तो पैरा 5 के उप-पैरा (4) का खंड (ii) म ेंअंजतम र्ाक्य के उपबंधों के अिुसार गैस मीटर का चक्रीय आयति। (ख) यदि लाग ूहो, तो पैरा 5 के उप-पैरा (4) का खंड (iii) के प्रार्धािों के अिुसार गैस मीटर का पल्स िैक्टर।[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 43 (ii) पुिरुत्पािकता,– पैरा 4 के उप-परै ा (6) म ें बताई गई त्रुठट की पिु रुत्पािकता की अपेिा का अिुपालि पैरा 11 के उप-परै ा (5) के खंड (ii) के उप-खंड (ख) के अिरूु प फ्लो रेट पर अर्धाठरत दकया िाता है, िो Q के बराबर या उससे अजधक ह।ै इिमें से प्रत्येक t फ्लो रेट के जलए, त्रुठटयों को साधारण रूप से िह बार स्ट्र्तत्रं रूप से जिधावठरत दकया िाएगा, िबदक प्रत्येक क्रजमक माप के बीच फ्लो रेट में बिलार् दकया िाएगा। प्रत्येक फ्लो रेट पर त्रुठट की पुिरुत्पािकता जिधावठरत की िाएगी। यदि पहल े तीि मापों की त्रुठट की पुिरुत्पािकता 1/6 एमपीई के बराबर या उससे कम ह,ै तो अपेिा परू ी मािी िाएगी। ठटप्पण: उच्च िबार् पर उपयोग दकए िाि े र्ाल े गैस मीटरों के जलए, यह परीिण न्यिू तम पठरचालि िबार् पर दकया िािा चाजहए। (iii) पुिरार्तिव ीयता,– पैरा 4 के उप-परै ा (7) में बताई गई त्रुठट की पुिरार्ृजि की अपेिा का अिुपालि Q , Q, और Q की फ्लो रेट पर min t max अर्धाठरत दकया िाता ह।ै इिमें से प्रत्येक फ्लो रेट पर, त्रुठटयों को तीि बार अर्धाठरत दकया िाता ह ै और न्यूितम और अजधकतम मापी गई त्रुठट के बीच अंतर की गणिा की िाती ह।ै ठटप्पण: उच्च िबार् पर उपयोग दकए िाि े र्ाल े गैस मीटरों के जलए, यह परीिण न्यिू तम पठरचालि िबार् पर दकया िािा चाजहए। (iv) अजभजर्न्यास,– िब तक जर्जिमावता द्वारा यह जिर्िवष्ट ि दकया िाए दक गैस मीटर का उपयोग केर्ल कुि जिजश्चत माउंटटंग अजभजर्न्यासों में ही दकया िािा ह,ै तब तक यह स्ट्थाजपत दकया िािा चाजहए दक मीटर का अजभजर्न्यास माप व्यर्हार को प्रभाजर्त करता ह ैया िहीं। जिम्नजलजखत अजभजर्न्यासों में परीिण दकया िाएगा,– (क) िैजति, (ख) ऊध्र्ावधर प्रर्ाह-ऊपर, (ग) ऊध्र्ावधर प्रर्ाह-िीच,े और पैरा 11 के उप-परै ा (6) के खंड (i) में बताए गए सटीकता माप इि अजभजर्न्यासों में दकए िाते ह।ैं यदि जर्जिमावता द्वारा केर्ल कुि जिजश्चत अजभजर्न्यास जिधाठव रत दकए गए ह ैं तो केर्ल उन्हीं अजभजर्न्यासों में परीिण दकया िाएगा। जर्जभन्न सटीकता मापों के पठरणामों का मूल्यांकि पैरा 4 के उप-पैरा (13) के खडं (i) में जिधावठरत अपेिाओं के अिुसार मध्यर्ती समायोिि के जबिा दकया िाता ह।ै यदि मध्यर्ती समायोिि के जबिा सभी जिधावठरत अजभजर्न्यासों के जलए अपेिाओं को परू ा िहीं दकया िाता है, तो मीटर को केर्ल एक जिजश्चत अजभजर्न्यास में उपयोग करिे के जलए जचजह्ित दकया िाएगा, िैसा दक पैरा 6 के उप-पैरा (1) के खंड (i) के उप-खंड (ि) में ििावया गया ह।ै44 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (v) फ्लो की दििा,– यदि लागू हो, तो परै ा 11 के उप-पैरा (6) के खंड (i) में बताए गए सटीकता माप फ्लो की िोिों दििाओं में होंगे। जर्जभन्न सटीकता मापों के पठरणामों का मूल्यांकि मध्यर्ती समायोििों के जबिा पैरा 4 के उप-परै ा (13) के खडं (ii) म ें जिर्िष्टव अपेिाओं के साथ दकया िाएगा। यदि मध्यर्ती समायोिि के जबिा फ्लो की िोिों दििाओं दििाओं के जलए अपेिाओं को पूरा िहीं दकया िाता है, तो मीटर को केर्ल एक जिजश्चत दििा म ें उपयोग करि े के जलए जचजह्ित दकया िाएगा, िैसा दक पैरा 5 के उप-परै ा (2) म ें ििावया गया ह।ै (vi) कायविील िबार्,– पैरा 11 के उप-परै ा (6) म ें खडं (i) में बताए गए सटीकता माप कम स े कम न्यूितम और अजधकतम कायविील िबार् पर दकए िाते ह।ैं जर्जभन्न सटीकता मापों के पठरणामों का मूल्यांकि मध्यर्ती समायोिि के जबिा पैरा 4 के उप-पैरा (8) में जिधावठरत अपेिाओं के साथ दकया िाता ह।ै यदि मध्यर्ती समायोिि के जबिा कायविील िबार् सीमा की अपेिाओं को पूरा िहीं दकया िाता है, तो उपयोग में लात े समय या तो कायविील िबार् सीमा को कम दकया िाएगा या कायविील िबार् सीमा को कई श्रेजणयों में जर्भाजित दकया िाएगा। र्ैकजल्पक रूप से िबार् सुधार लाग ूदकया िाएगा। ऐसी प्रौद्योजगदकयों के जलए िो िबार् या डायाफ्राम मीटर के प्रजत असंर्ेिििील साजबत हुई हैं, यह परीिण लागू िहीं होता ह।ै (vii) तापमाि,– (क) गैस मीटर की तापमाि जिभवरता का मूल्यांकि िीचे बताए गए तरीकों में से एक द्वारा जर्जिमावता द्वारा जिर्िवष्ट तापमाि सीमा में दकया िाएगा। इि रीजतयों को जिम्नजलजखत आिि व क्रम में क्रमबद् दकया गया ह,ै िामत:- (I) जर्जभन्न तापमािों पर फ्लो परीिण,– फ्लो परीिण पैरा 11 के उप-पैरा (6) के खडं (vii) के उप-खंड (क) में जिर्िष्टव पठरर्ेिी तापमाि के बराबर गैस तापमाि पर दकए िाते ह।ैं केर्ल मलू जस्ट्थजतयों पर आयति दिखाि े र्ाल े अतं र्िवर्मवत रूपांतरण उपकरण र्ाल े गैस मीटरों के जलए भी प्रर्ाह परीिण परै ा 11 के उप-पैरा (6) के खंड (vii) के उप-खंड (ख) में जिर्िवष्ट पठरर्ेिी तापमाि से जभन्न गैस तापमाि के साथ दकए िाि े चाजहए। (II) जर्जभन्न तापमािों पर िो-फ्लो जस्ट्थजतयों में मीटर के अप्रजतबंजधत फ्लो रेट आउटपुट की जिगरािी,– िो-फ्लो जस्ट्थजतयों में, मीटर के अप्रजतबंजधत फ्लो रेट आउटपुट का उपयोग मीटर की सटीकता पर तापमाि के प्रभार् को जिधावठरत करिे के जलए दकया िाता ह।ै परीिण कम से कम संिभव तापमाि पर और न्यूितम और अजधकतम कायविील तापमाि पर दकया िाता ह।ै मीटर र्क्र पर फ्लो रेट में बिलार् के प्रभार् को ध्याि में रखते हुए, जर्जभन्न तापमािों पर माप के पठरणामों का मूल्यांकि पैरा 4 के उप-पैरा (9) म ें जिधावठरत अपेिाओं के अिुसार दकया िाता ह।ै उिाहरण: सटीकता र्गव 1 गैस मीटर का अप्रजतबंजधत फ्लो रेट आउटपुट तापमाि जभन्नता के कारण +1 L/h के साथ बिल िाता ह।ै इस मीटर की संिभव जस्ट्थजतयों म ें प्रारंजभक त्रुठट 200 L/h के Q पर +0.3% थी। Q पर तापमाि जभन्नता के min min[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 45 कारण प्रभार् 1/200 × 100% = + 0.5% ह।ै + 0.8% का अंजतम माि लाग ू अजधकतम स्ट्र्ीकायव त्रुठट की सीमाओं के भीतर रहता ह।ै ठटप्पण: अप्रजतबंजधत फ्लो रेट र्ह फ्लो रेट होता ह ैजिस पर जिम्न प्रर्ाह कट-ऑि (यदि मौििू हो) सदक्रय िहीं होता ह।ै (III) मीटर के जिमावण का मल्ू यांकि,– ऐसे मामलों में िब तापमाि के प्रभार् को जिधावठरत करिे के जलए मीटर का परीिण िहीं दकया िा सकता है, तो मीटर जिमावण पर तापमाि के अपेजित प्रभार् से उत्पन्न अजिजश्चतता का मल्ू यांकि दकया िाएगा। आर्ासीय मीटरों के जलए प्रर्ाह परीिण आज्ञापक ह ै िैसा दक अिछु िेि 11 के उप-अिुछिेि (6) के खडं (vii) के उप-खंड (क) के मि (I) में जिर्िष्टव ह।ै (ख) समाि गैस और पठरर्ेि तापमाि के साथ फ्लो परीिण फ्लो परीिण परै ा 11 के उप-परै ा (5) के खंड (ii) के उप-खडं (ख) म ें जिधावठरत प्रर्ाह िरों पर Q स े Q तक की सीमा म ें t max दकए िाते ह,ैं जिसम ें गैस का तापमाि पठरर्ेि के तापमाि (5° C के भीतर) के बराबर होता है, जिसका क्रजमक रूप इस प्रकार होता ह,ै– (I) संिभव तापमाि; (II) अजधकतम पठरर्ेि तापमाि; (III) न्यिू तम पठरर्ेि तापमाि; (IV) संिभव तापमाि। समाि गैस और पठरर्ेि तापमाि के जलए परै ा 4 के उप-पैरा (9) म ेंजिर्िवष्ट अपेिाओं का अिुपालि दकया िाएगा। (ग) असमाि गैस और पठरर्ेि तापमाि के साथ फ्लो परीिण,– प्रर्ाह परीिण, परीिणाधीि गैस मीटर को संिभव तापमाि के बराबर जस्ट्थर पठरर्ेिी तापमाि पर रखत े हुए और इस क्रम में दकया िाता ह,ै िामत:- (I) गैस का तापमाि 40° C; (II) गैस का तापमाि 0° C। त्रुठट Q और Q पर जिधावठरत की िाती ह।ै त्रुठटयों का जिधावरण गैस के तापमाि के जस्ट्थर होिे के बाि ही दकया िाएगा। t max पैरा 4 के उप-पैरा (9) में जिधावठरत असमाि गैस और पठरर्ेि के तापमाि की अपेिाओं का अिुपालि दकया िाएगा। ठटप्पण: उपयुवि तापमाि परीिण के जसर्ाए, र्ैकजल्पक रूप से जिम्नजलजखत तापमाि जस्ट्थजतयों का उपयोग करत े हुए परीिण दकया िा सकता ह:ै 1. गैस का तापमाि 20° C और गैस मीटर का तापमाि 40° C; 2. गैस का तापमाि 20° C और गैस मीटर का तापमाि 0 °C।46 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (viii) फ्लो म ेंग़िब़िी,– जिि गैस मीटरों की सटीकता फ्लो म ें ग़िब़िी से प्रभाजर्त होती है, उन्ह ें उपाबंध ख में जिर्िवष्ट परीिणों के जलए प्रस्ट्तुत दकया िाएगा। परीिणों के िौराि मीटरों को जर्जिमावता के जर्जििेिों के अिुसार इंस्ट्टॉल दकया िाएगा। यदि ऐसे गैस मीटर जिर्िवष्ट दकए गए ह ैं और जचजह्ित दकए गए ह ैं दक उन्ह ें गंभीर ग़िब़िी पैिा करिे र्ाली पाइप्पगं व्यर्स्ट्था में िहीं डाला िािा चाजहए, तो उिका परीिण केर्ल उपाबंध ख ख2 (फ्लो में हल्की ग़िब़िी) के अिुसार दकया िािा चाजहए। सारणी ख.1 में जिर्िष्टव पाइप्पगं व्यर्स्ट्था का पालि दकया िाएगा, उि सारणी में (क) से (ि) तक दिए गए परीिणों को केर्ल हल्के प्रर्ाह ग़िब़िी पैिा करिे र्ाला मािा िाता ह।ै पैरा 4 के उप-पैरा (13) का खडं (iii) में जिधावठरत अपेिाएं लागू होंगी। (ix) स्ट्थाजयत्र्,– आंतठरक गजतमाि भागों र्ाल ेसभी गैस मीटर और आतं ठरक गजतमाि भागों के जबिा गैस मीटर जििका अजधकतम समतल्ु य आयति फ्लो रेट 25 m3/h तक ह,ै स्ट्थाजयत्र् परीिण के जलए प्रस्ट्तुत दकए िाते ह।ैं इस परीिण म,ें मीटर का उपयोग जिि गैसों के जलए दकया िािा ह ै अपेजित समयार्जध के िौराि उि गैसों के जिरंतर फ्लो के सपं कव म ें रहिा िाजमल ह।ै यदि जर्जिमावता िे प्रिर्ितव दकया ह ै दक गैस मीटर की सामग्री संरचिा गैस संरचिा के प्रजत पयाप्तव रूप से असंर्ेिििील है, तो मॉडल अिुमोिि के जलए उिरिायी जििेिक (जर्जधक मापजर्ज्ञाि) हर्ा या दकसी अन्य उपयुि प्रकार की गैस के साथ स्ट्थाजयत्र् परीिण करि े का जिणवय ल े सकता ह।ै लागू फ्लो रेट कम स े कम 0.8 Q होता ह।ै यह परीिण न्यिू तम max कायविील िबार् पर करिा होगा। परीिण से पहले और बाि म ेंएक ही संिभव उपकरण का उपयोग करिा होगा। मॉडल अिुमोिि के जलए जिम्मेिार जििेिक (जर्जधक मापजर्ज्ञाि) आर्ेिक के परामिव से सारणी 8 में दिए गए जर्कल्पों म ें से स्ट्थाजयत्र् परीिण के जलए प्रस्ट्तुत दकए िािे र्ाले समाि प्रकार के मीटरों की संख्या का चयि करेगा। यदि जर्जभन्न आकार िाजमल दकए िाते ह,ैं तो प्रस्ट्ततु दकए िािे र्ाल े मीटरों की कुल संख्या जर्कल्प 2 म ें बताई गई संख्या के अिुसार होगी। सारणी 8. परीिण दकये िाि ेर्ाले मीटरों की संख्या क्रम सं. अजधकतम समतल्ु य आयति फ्लो रेट [m3/h] परीिण दकये िािे र्ाल ेमीटरों की संख्या जर्कल्प 1 जर्कल्प 2 (1) (2) (3) (4) (क) Q ≤ 25 3 6 max (ख) 25 < Q ≤ 100 2 4 max (ग) Q > 100 1 3 max स्ट्थाजयत्र् परीिण के बाि गैस मीटरों का परीिण परै ा 11 के उप-पैरा (5) के खडं (ii) का उप-खंड (ख) म ें जिधावठरत प्रर्ाह िरों पर दकया िाता ह।ै[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 47 गैस मीटर परै ा 4 के उप-परै ा (10) म ें जिधावठरत अपेिाओं का अिपु ालि करेंग े (उिम ें स े एक को िो़िकर, यदि स्ट्थाजयत्र् परीिण जर्कल्प 2 के अिुसार कई गैस मीटरों पर दकया गया ह)ै । (x) ड्राइर् िाफ्ट (टॉकव),– 1.2 kg/m3 के घित्र् पर गैस का उपयोग करत े हुए, ड्राइर् िाफ्ट र्ाले गैस मीटर को अजधकतम संभर् टॉकव पर रखा िाता ह।ै िॉल्ट का मल्ू यांकि Q पर दकया िाता ह।ै min पैरा 4 के उप-पैरा (13) के खडं (iv) म ेंजिधावठरत अपेिाओं को लाग ूकरिा होगा। िब एक प्रकार के गैस मीटर में जर्जभन्न आकार िाजमल होते हैं, तो यह परीिण केर्ल सबसे िोटे आकार पर ही दकया िािा चाजहए, ककंतु दक ब़िे गैस मीटर के जलए समाि टॉकव जिर्िवष्ट दकया गया हो और बाि र्ाले के ड्राइर् िाफ्ट का आउटपुट जस्ट्थरांक समाि या अजधक हो। (xi) ओर्रलोड फ्लो,– आंतठरक गजतिील भागों र्ाल े गैस मीटर ओर्रलोड फ्लो के परीिण के अधीि होत े ह।ैं ओर्रलोड स े पहल े और बाि म ें गैस मीटर की त्रुठट पैरा 11 के उप-पैरा (5) के खडं (ii) का उप-खंड (ख) के अिुसार इसकी संपूण व फ्लो रेट सीमा के जलए जिधावठरत की िाती ह।ै पैरा 4 के उप-पैरा (11) में जिधावठरत अपिे ाएं लाग ूहोंगी। (xii) जर्जभन्न गैस,ें – गैस मीटर िो जर्जभन्न गैसों के जलए उपयोग दकए िाि े के जलए अजभप्रते हैं, उन्ह ें जर्जिमावता द्वारा जिर्िष्टव गैसों के साथ पैरा 11 के उप-पैरा (6) के खडं (i) में बताए अिुसार सटीकता माप के जलए प्रस्ट्तुत दकया िाता ह।ै जर्जिमावता के प्रस्ट्तार् को ध्याि म ें रखत े हुए, मॉडल अिुमोिि के जलए उिरिायी जििेिक (जर्जध माप जर्ज्ञाि) परीिण के िौराि उपयोग की िाि े र्ाली गैसों का जिणवय लेंगे, िो परीिण के अधीि गैस मीटर के अिुप्रयोग उद्दश्े य पर जिभरव करेगा। पैरा 4 के उप-पैरा (13) के खडं (v) में जिधावठरत अपेिाओं का अिुपालि करिा होगा। यदि मध्यर्ती समायोिि के जबिा सभी जर्जभन्न गैसों के जलए अपेिा ए ं पूरी िहीं होती हैं, तो मॉडल अिुमोिि के जलए जिम्मेिार जििेिक (जर्जधक मापजर्ज्ञाि) इस अर्लोकि की ठरपोटव करेगा और ऑपरेटटंग गैसों की इस श्रेणी को जिर्िवष्ट करेगा जिसके जलए गैस मीटर ि े अपेिाओं को परू ा दकया ह।ै (xiii) कंपि और झटके,– अजधकतम 10 दकलोग्राम र्िि र्ाले गैस मीटर कंपि और झटकों के परीिण के अधीि होत े ह।ैं इस र्िि से अजधक र्िि र्ाले गैस मीटर के जलए मीटर के केर्ल इलेक्रॉजिक भाग का परीिण दकया िािा ह।ै इि परीिणों से पहल े और बाि म ें गैस मीटर की आंतठरक त्रुठट पैरा 11 के उप-परै ा (5) के खडं (ii) के उप-खंड (ख) के अिुसार परू े फ्लो रेट रेंि पर जिधावठरत की िाती ह।ै पैरा 4 के उप-पैरा (12) में जिधावठरत अपिे ाओं का अिुपालि करिा होगा। (xiv) जर्जिमेय घटक,– गैस मीटरों के जलए जििके कुि घटकों को जर्जिमेय मािा िाता है, िैसा दक जिमावता द्वारा जिर्िवष्ट दकया गया है, जर्जिमेयता का प्रभार् Q पर जिधावठरत दकया िाएगा। t48 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] ठटप्पण: ऊपरी फ्लो रेंि की अजधकतम स्ट्र्ीकायव त्रुठट सीमाएं लाग ूहोंगी। (Q ≥ Q) t यह सटीकता परीिण जिम्नजलजखत क्रम म ेंतीिों चरणों म ेंसे प्रत्येक पर करिा होगा: (क) प्रारंजभक कॉजन्िगरेिि का उपयोग करते समय; (ख) घटक के आिाि-प्रिाि के बाि; (ग) मूल घटक को पिु ः स्ट्थाजपत करिे के बाि। तीिों सटीकता परीिणों म ें से दकसी के पठरणामों के बीच अजधकतम अंतर की गणिा करके िॉल्ट स्ट्थाजपत करिा होगा। पैरा 4 के उप-पैरा (13) के खडं (vi) म ेंजिधावठरत अपेिाएं लाग ूहोंगी। (xv) इलेक्राजिक्स,– इलेक्रॉजिक घटकों र्ाल े गैस मीटरों के जलए, पैरा 4 के उप-परै ा (13) के खंड (vii) म ें जिर्िष्टव अपेिाओं का भी अिुपालि दकया िाएगा। भाग 2 में जिर्िष्टव परीिण जर्जधयों का उपयोग करके प्रिििव परीिण जिष्पादित दकए िाएंगे, और सारणी 4 और सारणी 5 म ें जिर्िवष्ट अपिे ाओं का अिुपालि सुजिजश्चत दकया िाएगा। प्रत्येक परीिण के बाि यह सत्याजपत दकया िाएगा दक डेटा की कोई हाजि िहीं हुई ह।ै यदि गैस मीटर के इलेक्रॉजिक उपकरण एक अलग हाउप्संग म ें जस्ट्थत हैं, तो उिके इलेक्रॉजिक कायों का परीिण मीटर की रेटेड पठरचालि जस्ट्थजतयों का प्रजतजिजधत्र् करि े र्ाले िकली संकेतों द्वारा गैस मीटर के मापक रांसड्यूसर से स्ट्र्तंत्र रूप स े दकया िा सकता ह।ै इस मामल ेमें इलेक्रॉजिक उपकरणों का परीिण उिके अंजतम हाउप्संग म ेंदकया िाएगा। सभी मामलों म,ें सहायक उपकरणों का अलग से परीिण दकया िा सकता ह।ै सारणी 4 और सारणी 5 म ेंजर्जिर्िवष्ट परीिण जिम्नजलजखत जस्ट्थजतयों में करिा होगा, अथावत्:- (क) कंपि और मकैजिकल झटका परीिण करिे के समय के अलार्ा, परीिण के अधीि मीटर को चालू रखा िाता है; (ख) गैस मीटर के प्रििवि की जिभवरता का मल्ू यांकि िीचे बताए गए फ्लो मोड म ें से एक में दकया िाएगा, जिस े जिम्नजलजखत आििव क्रम में रैंक दकया िाएगा:- (I) र्ास्ट्तजर्क फ्लो के िौराि, या (II) मीटर के अप्रजतबंजधत फ्लो रेट आउटपुट की जिगरािी करत े समय जबिा फ्लो की जस्ट्थजत में। बाि के मामल े में, मीटर र्क्र पर फ्लो रेट बिलार् के प्रभार् को ध्याि म ें रखते हुए सारणी 4 और सारणी 5 म ें इंजगत अपेिाओं के अिुपालि की िाचं की िाती ह।ै ठटप्पण: अजधकांि इलेक्रॉजिक मीटर में कम फ्लो रेट के जलए कट-ऑि होता ह।ै इस परीिण के जलए इस कट-ऑि को बंि दकया िािा चाजहए, जिससे फ्लो रेट आउटपुट अप्रजतबंजधत फ्लो रेट के अिरूु प हो। (xvi) सहायक उपकरणों स ेप्रभार्,–[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 49 जर्जिष्ट िंक्िि को लाग ू करके और उसके जबिा, सहायक उपकरणों के सभी कायों का प्रभार् Q पर एक सटीकता min परीिण करके जिधावठरत दकया िाता ह।ै प्रभार् िगण्य (=< 0.1MPE) होगा। (7) मॉडल अिमु ोिि प्रमाणपत्र,– मॉडल अिुमोिि प्रमाणपत्र पर जिम्नजलजखत िािकारी और डेटा प्रिर्िवत होंगे, िामत:- (क) उस कंपिी का िाम और पता जिसे मॉडल अिुमोिि प्रमाणपत्र िारी दकया गया है; (ख) जर्जिमावता का िाम; (ग) गैस मीटर का प्रकार या र्ाजणजज्यक पििाम; (घ) प्रमुख माप-संबंधी और तकिीकी जर्िेषताएं िैसे दक सटीकता र्गव, माप की इकाइयां, Q , Q और Q के max min t माि, पैरा 5 के उप-परै ा (1) म ें जिधावठरत पठरचालि जस्ट्थजतया,ं अजधकतम कायविील िबार्, किेप्क्टंग टुक़िों का िॉजमिल आंतठरक व्यास और र्ॉल्यूमेठरक गैस मीटर के मामले में, चक्रीय आयति का िॉजमिल माि; (ङ) मॉडल अिुमोिि जचह्ि; (च) मॉडल अिुमोिि की र्ैधता अर्जध (यदि लाग ूहो); (ि) ड्राइर् िाफ्ट से सुसजित मीटरों के जलए: ड्राइर् िाफ्ट की जर्िेषताएं; (ि) पयावर्रण र्गीकरण; (झ) पैरा 6 के उप-पैरा (1) में अपेजित जचह्िों और इंजस्ट्क्रप्िि के स्ट्थाि की िािकारी, प्रारंजभक सत्यापि जचह्ि और मुहरें (िहा ंलागू हो, िोटोग्राि या जचत्र के रूप में); (ञ) मॉडल अिुमोिि प्रमाणपत्र के साथ संलग्न िस्ट्तार्ेिों की सूची; (ट) कोई जर्िेष ठटप्पणी। 12 प्रारंजभक सत्यापि और पिु ः सत्यापि.– (1) साधारण,– प्रारंजभक सत्यापि का उद्देश्य, सेर्ा में लािे से पहल,े व्यजिगत गैस मीटर की जिम्नजलजखत अपिे ाओं के साथ अिुपालिा को सत्याजपत करिा ह,ै- (i) ऐसे आकलि के िौराि उपयुि एर्ं पयावप्त सटीक माप संिभों का उपयोग दकया िाएगा। (ii) इि संिभों का अंिांकि र्ैध होगा तथा राष्ट्रीय और अंतरावष्ट्रीय मापि मािकों के अिरूु प उिकी पहचाि प्रमाजणत होगी। (iii) लागू परीिाएं और परीिण गसै मीटर के उत्पािि संयंत्र में, अंजतम माउंटटंग स्ट्थाि पर या दकसी अन्य मध्यर्ती परीिण स्ट्थल पर दकए िा सकते ह ैं िो अपेजित परीिाए ं और परीिण करि े के जलए उजचत और पयावप्त साधि प्रिाि करता ह।ै (iv) सत्यापि के जलए जिम्नजलजखत उपाय दकए िाएंगे,- (क) अिुमोदित प्रकार के अिुरूपता: गैस मीटर की िांच यह पता लगािे के जलए की िाएगी दक क्या यह अपिे अिुमोदित प्रकार के अिरूु प ह;ै (ख) प्रस्ट्ततु ीकरण: प्रारंजभक सत्यापि के जलए प्रस्ट्तुत दकए िाि े पर गैस मीटर चालू होिा चाजहए तथा सत्यापि जचह्ि और सील लगाि े के जलए मीटर पर अपेजित स्ट्थाि उपलब्ध होिा चाजहए;50 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (ग) परीिण की जस्ट्थजतयां: पैरा 4 के उप-पैरा (3) और पैरा 4 के उप-परै ा (4) की सटीकता अपेिाओं को सत्याजपत दकया िाएगा िबदक गैस की जस्ट्थजत को उपयोग म ेंलािे के बाि मीटर की इजछित पठरचालि जस्ट्थजतयों (िबार्, तापमाि, गैस प्रकार) के यथासंभर् करीब रखा िाएगा। सत्यापि उस प्रकार की गैस (िसै े र्ायु) के साथ भी दकया िा सकता है, जिसके जलए मीटर का उपयोग करिे का आिय ह,ै यदि सत्यापि के जलए उिरिायी अजधकाठरयों को यकीि ह ै दक जर्जभन्न गैसों के साथ मल्ू यांकि परीिण के पठरणाम से [परै ा 11 के उप-पैरा (5) के खडं (ii) का उप-खडं (ग) िेखें] या परीिण के अधीि मीटर के तकिीकी जिमावण से तुलिीय पठरणाम प्राप्त होंगे। यदि अपेजित हो, तो गैसों के बीच अंतर के जलए सुधार कारक लाग ूदकए िाएंगे। (घ) फ्लो रेट: गैस मीटर का परीिण पैरा 11 के उप-परै ा (5) के खंड (ii) के उप-खंड (ख) में जिर्िवष्ट फ्लो रेट पर दकया िाएगा। प्रारंजभक सत्यापि कम फ्लो रेट पर दकया िा सकता है, परंतु यह जर्कल्प सत्यापि करिे के जििेिों द्वारा समर्थवत हो [पैरा 11 का उप-परै ा (8) िेख]ें । ठटप्पण 1: डायाफ्राम गैस मीटरों का सत्यापि सभी मामलों में फ्लो रेट Q , 0.2·Q और Q पर परीिणों max max min के प्रििवि तक सीजमत ह।ै ठटप्पण 2: रोटरी जपस्ट्टि गैस मीटर से संबंजधत परीिण प्बंिओंु की संख्या जििेिक(जर्जधक मापजर्ज्ञाि) के जििेि पर कम की िा सकती ह।ै (ङ) अजभजर्न्यास और फ्लो की दििा: यदि गैस मीटर का उपयोग एक से अजधक फ्लो की दििा या मीटर अजभजर्न्यास में दकया िा सकता है, तो सत्यापि िोिों फ्लो की दििाओं और जर्जिमावता द्वारा जिर्िष्टव मीटर अजभजर्न्यासों में दकया िाएगा, िब तक दक मॉडल अिुमोिि के िौराि इसकी िाचं िहीं की गई हो, यह साजबत िहीं हुआ हो और अिुमोिि प्रमाणपत्र में ठरपोटव िहीं की गई हो दक मीटर का प्रििवि मीटर अजभजर्न्यास (पैरा 4 उप-िैरा (13) के खंड (i) अपेिा परू ी हो गई ह)ै या फ्लो की दििा (पैरा 4 के उप-परै ा (13) के खडं (ii) अपेिा परू ी हो गई ह)ै स ेस्ट्र्तंत्र ह।ै (च) समायोिि: यदि त्रुठट र्क्र या डब्ल्यूएमई क्रमिः परै ा 4 के उप-परै ा (3) और पैरा 4 के उप-परै ा (4) में जिर्िवष्ट अपेिाओं को पूरा िहीं करता ह,ै तो गैस मीटर को इस तरह समायोजित दकया िाएगा दक डब्ल्यूएमई समायोिि और अजधकतम स्ट्र्ीकायव त्रुठट के अिुसार िून्य के करीब हो। ठटप्पण 1: एकल प्बंि ु समायोिि का उपयोग करते समय समायोिि बिलि े के बाि सभी परीिणों को िोहरािा अपेजित िहीं ह।ै एक फ्लो रेट पर एक परीिण को िोहरािा और जपिले र्ाले स े अन्य त्रुठट मािों की गणिा करिा पयावप्त ह।ै ठटप्पण 2: उच्च िबार् अिप्रु योगों के जलए ऑपरेटटंग जस्ट्थजतयों को ध्याि म ें रखते हुए समायोिि दकया िाता ह।ै (ि) आउटपुट िाफ्ट: यदि गैस मीटर में आउटपुट िाफ्ट द्वारा संचाजलत सहायक उपकरणों को िाजमल करिे का इरािा ह,ै तो इि उपकरणों को सत्यापि के िौराि िो़िा िाएगा, िब तक दक सत्यापि के बाि संलग्न करिा स्ट्पष्ट रूप स ेअजधकृत ि हो।[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 51 (2) सेर्ाकालीि जिरीिण या पुिः सत्यापि हते ु अजतठरि अपेिाओं के प्रयोिि के जलए, जिम्नजलजखत मीटरों म ें िाजमल होंगे,- (i) र्ॉल्यूमेठरक मीटर म ें एकीकृत पल्स आरंभक, ठरमोट रजिस्ट्टर (इंडेक्स), ठरमोट मीटर-रीप्डगं या स्ट्र्चाजलत मीटर- रीप्डंग (एएमआर) जडर्ाइस, सुधार जडर्ाइस या रैजखकीकरण फंक्िि (रैजखकीकरण फंक्िि को इलक्े रॉजिक र्ॉल्यूमेठरक मीटर या फ्लो कंप्यूटर के सर्कवट जडजाइि म ेंया एक अलग सुधार जडर्ाइस म ेंिाजमल दकया िा सकता ह)ै , इर्ेंट लॉगर और ऑजडट रेल फंक्िि और इलेक्रॉजिक र्ॉल्यूम रूपांतरण फंक्िि िाजमल ह।ैं (ii) मास-फ्लो मीटर में एकीकृत पल्स इजिजिएटर, ठरमोट इंडेक्स, ठरमोट मीटर-रीप्डंग या स्ट्र्चाजलत मीटर-रीप्डगं (एएमआर) जडर्ाइस और इर्ेंट लॉगर िाजमल ह।ैं (iii) आधार िबार् और तापमाि रूपांतरण उपकरण या ठरकॉर्डिंग उपकरण म ें एकीकृत पल्स इजिजिएटर, ठरमोट-मीटर- रीप्डंग या स्ट्र्चाजलत-मीटर-रीप्डंग उपकरण, और इर्ेंट लॉगर और ऑजडट रेल फंक्िि िाजमल ह।ैं उपाबधं क: इलक्े रॉजिक उपकरणों या जडर्ाइस के जलए पयार्व रण परीिण (आज्ञापक) 1. साधारण,– यह उपाबंध इलेक्रॉजिक्स और उिके सहायक उपकरणों र्ाल े गैस मीटरों और जर्जिर्िवष्ट र्ातार्रण एर्ं जर्जिर्िवष्ट जस्ट्थजतयों में उिके द्वारा दकए िा सकिे र्ाले कायों को सत्याजपत करि े के जलए अजभप्रेत प्रििवि परीिणों को जर्जिर्िवष्ट करता ह।ै प्रत्येक परीिण, िहा ाँउपयुि हो, त्रुठट जिधावठरत करिे के जलए संिभव जस्ट्थजतयों को इंजगत करता ह।ै ये परीिण दकसी अन्य जिधावठरत परीिण के परू क ह।ैं िब एक प्रभार् मात्रा के प्रभार् का मूल्यांकि दकया िा रहा हो, तो अन्य सभी प्रभार् मात्राओं को संिभव जस्ट्थजतयों की सीमा के भीतर रखा िािा चाजहए। 2. परीिण स्ट्तर,– प्रत्येक परिॉमेंस टेस्ट्ट के जलए, जर्जिष्ट परीिण जस्ट्थजतयााँ जर्जिर्िवष्ट की गई ह।ैं ये िलर्ायु और यांजत्रक पयावर्रण जस्ट्थजतयों के अिरूु प ह ैंजििके संपकव में उपकरण साधारणतया आत े ह।ैं परीिण प्रयोगिाला इि पयावर्रणीय जस्ट्थजतयों के अिरूु प परीिण स्ट्तरों पर जिष्पािि परीिण करेगी। 3. सिं भ वित,ें – पैरा 11 के उप-पैरा (5) के खडं (ii) के उप-खंड (क) मे जर्जिर्िष्टव ािुसार। 4. अिपु ालि परीिण (िलर्ाय ुसबं धं ी),– (1) जस्ट्थर तापमाि,– सारणी 1. (i) िष्ु क ऊष्मा (गरै -सघं िक): प्रभार् परीिण,– परीिण का उद्देश्य उच्च पयावर्रणीय तापमाि की जस्ट्थजतयों के अधीि अिुपालि का सत्यापि। (1) (2) संिेप में परीिण प्रदक्रया परीिण में जिर्िष्टव समय के जलए "फ्री एअर" जस्ट्थजतयों के अधीि जिर्िष्टव उच्चतम तापमाि के संपकव में आिा िाजमल ह ै (जिर्िष्टव समय ईयूटी के तापमाि जस्ट्थरता तक पहुचं िे के बाि का समय ह)ै ।52 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] गमव और िंडा करि े के िौराि तापमाि में पठरर्तिव 1 जडग्री सेजल्सयस/जमिट से अजधक िहीं होिा चाजहए। परीिण र्ातार्रण की पूण व आद्रतव ा 20 ग्राम/घि मीटर से अजधक िहीं होिी चाजहए। िब परीिण 35 जडग्री सेजल्सयस से कम तापमाि पर दकया िाता ह,ै तो सापेि आद्रवता 50% स ेअजधक िहीं होिी चाजहए। तापमाि जिर्िवष्ट उच्चतम तापमाि ° सेजल्सयस अर्जध 2 एच सारणी 2. (ii) िीत: प्रभार् परीिण,– परीिण का उद्देश्य जिम्न पयावर्रणीय तापमाि की जस्ट्थजतयों के अधीि अिपु ालि का सत्यापि। (1) (2) संिेप में परीिण प्रदक्रया परीिण म ें जिर्िवष्ट समय के जलए " फ्री एअर " जस्ट्थजतयों के अधीि जिर्िष्टव जिम्नतम तापमाि के संपकव म ें आिा िाजमल ह ै (जिर्िवष्ट समय परीिण के अधीि उपकरण के तापमाि जस्ट्थरता तक पहुचं िे के बाि का समय ह)ै । गमव और िंडा करि े के िौराि तापमाि में पठरर्तिव 1 जडग्री सेजल्सयस/जमिट से अजधक िहीं होिा चाजहए। अंतराष्ट्रव ीय इलेक्रोटेदिकल आयोग जर्जिर्िवष्ट करता ह ै दक तापमाि बढ़ि े स े पहल े परीिण के अधीि उपकरण की जबिली बंि कर िी िाएगी। तापमाि जिर्िवष्ट जिम्नतम तापमाि ° सेजल्सयस अर्जध 2 एच (2) िमी र्ाली उष्मा,– सारणी 3. (i) िमी र्ाली उष्मा, जस्ट्थर-अर्स्ट्था (गरै सघं िक): प्रभार् परीिण,– परीिण का उद्देश्य उच्च पयावर्रणीय आद्रवता और जस्ट्थर तापमाि की जस्ट्थजतयों के अधीि अिुपालि का सत्यापि। (1) (2) संिेप में परीिण प्रदक्रया परीिण में एक जिजश्चत जिधावठरत अर्जध के जलए जिर्िष्टव तापमाि और जिर्िवष्ट जस्ट्थर सापेि आद्रवता का िोजखम िाजमल होता ह।ै परीिण के अधीि उपकरण को इस तरह से संभाला िाएगा दक उस पर पािी का कोई संघिि ि हो। गैस मीटर को 3 बार सटीकता परीिण से गुिरिा होगा: - तापमाि में र्ृजद् स ेपहल,े संिभव जस्ट्थजतयों पर; - उच्चतम तापमाि चरण के अंत में; - संिभव जस्ट्थजतयों म,ें तापमाि में जगरार्ट के 24 घंटे बाि। तापमाि जिर्िवष्ट उच्चतम तापमाि ° सेजल्सयस सापेजिक आद्रवता (आरएच) 93 % अर्जध 4 एच[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 53 सारणी 4. (ii) िमी र्ाली उष्मा, चक्रीय (सघं िक): बाधा परीिण,– परीिण का उद्देश्य चक्रीय तापमाि पठरर्तिव के साथ संयुि उच्च पयावर्रणीय आद्रतव ा की जस्ट्थजतयों के अधीि अिुपालि का सत्यापि। (1) (2) संिेप में परीिण प्रदक्रया परीिण म ें 25 जडग्री सेजल्सयस और उजचत उच्चतम तापमाि के बीच चक्रीय तापमाि जभन्नता के संपकव में आिा िाजमल ह,ै िबदक तापमाि पठरर्तवि और जिम्नतम तापमाि चरणों के िौराि सापेि आद्रवता 95% से ऊपर और उच्चतम तापमाि चरणों में 93% या उससे अजधक बिाए रखिा िाजमल ह।ै तापमाि र्ृजद् के िौराि परीिण के अधीि उपकरण पर सघं िि होिे की संभार्िा होती ह।ै 24 घंटे के चक्र म ेंिाजमल ह:ैं (1) 3 घंटे के िौराि तापमाि म ेंर्ृजद्। (2) चक्र की िरुु आत से 12 घंटे तक तापमाि उच्चतम तापमाि स्ट्तर पर बिा रहता ह।ै (3) 3 स े 6 घंटे की अर्जध के भीतर तापमाि जिम्नतम तापमाि स्ट्तर तक जगर गया, पहले डेढ़ घंटे के िौराि जगरार्ट की िर ऐसी थी दक जिम्नतम तापमाि का स्ट्तर 3 घंटे में पहुचं िाएगा। (4) 24 घंटे का चक्र पूरा होि ेतक तापमाि को जिम्नतम तापमाि स्ट्तर पर बिाए रखा िाता ह।ै सायजक्लक एक्सपोिर स े पहल े की जस्ट्थरीकरण अर्जध और बाि की पिु प्रावजप्त अर्जध ऐसी होगी दक परीिण के अधीि उपकरण के सभी भागों का तापमाि इसके अंजतम मूल्य के 3 जडग्री सेजल्सयस के भीतर हो। परीिण के िौराि उपकरण चालू दकया िाता ह;ै गैस प्रर्ाह की अपेिा िहीं होती ह।ै गैस मीटर को िोिों सटीकता परीिणों के अध्यधीि दकया िाएगा:- (क) संिभ वजस्ट्थजतयों म,ें तापमाि बढ़ि े से पहले और (ख) संिभ व ितों पर, अंजतम चक्र के कम स ेकम 4 घंटे बाि। उच्चतम तापमाि जिर्िवष्ट उच्चतम तापमाि ° सेजल्सयस अर्जध 2 चक्र 5. अिपु ालि परीिण (याजं त्रक),– सारणी 5. (1) कंपि (यािजृ छिक): बाधा परीिण,– परीिण का उद्देश्य यािजृ छिक कंपि की ितों के अधीि अिुपालि का सत्यापि। (1) (2) संिेप में परीिण प्रदक्रया परीिण में जिर्िष्टव समय के जलए कंपि के स्ट्तर का प्रििवि िाजमल ह।ै इसके बाि, परीिण के अधीि उपकरण का परीिण उसके साधारण माउंटटंग साधिों द्वारा एक किोर जस्ट्थरता पर लगाए गए तीि परस्ट्पर लंबर्त अिों म ें दकया िाएगा।54 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] परीिण के अधीि उपकरण को आम तौर पर इस तरह से स्ट्थाजपत दकया िाएगा दक गुरुत्र्ाकषवण र्ेक्टर उसी दििा म ें इंजगत करेगा िैसा दक यह साधारण उपयोग म ें होगा। िहां, मीटटरंग जसद्ांत के आधार पर गुरुत्र्ाकषवण बल के प्रभार् को िगण्य मािा िा सकता ह,ै र्हा ं परीिण के अधीि उपकरण को दकसी भी जस्ट्थजत म ें स्ट्थाजपत दकया िा सकता ह।ै उिाहरण: एक डायाफ्राम गैस मीटर का परीिण हमेिा एक सीधी जस्ट्थजत में दकया िािा चाजहए, प्रत्येक दििा के जलए जिसमें मीटर का परीिण दकया िािा ह।ै परीिण के िौराि उपकरण को चालू (जस्ट्र्छड ऑि) करि े की अपेिा िहीं ह।ै कुल आर्ृजि रेंि 10 हर्टि व – 150 हर्टि व कुल आरएमएस स्ट्तर 7 एम·एस-2 एएसडी स्ट्तर 10 हर्टि व - 20 1 एम2·एस-3 हर्टि व एएसडी स्ट्तर 20 हर्टिव - 150 –3 डीबी/ऑक्टेर् हर्टि व अिो की संख्या 3 प्रजत अि अर्जध 2 जमिट सारणी 6. (2) याजं त्रक िॉक: बाधा परीिण,– परीिण का उद्देश्य यांजत्रक िॉक की ितों के अधीि अिपु ालि का सत्यापि। (1) (2) संिेप में परीिण प्रदक्रया किोर सतह पर उपयोग की अपिी साधारण जस्ट्थजत में रखे गए परीिण के अधीि उपकरण को एक जिचले दकिारे की ओर झुकाया िाता ह ै और दिर परीिण सतह पर स्ट्र्तंत्र रूप से जगरि े दिया िाता ह।ै िीचे जगरिे की ऊंचाई जर्परीत दकिारे और परीिण सतह के बीच की िरू ी ह।ै तथाजप, िीचे और परीिण सतह द्वारा बिाया गया कोण 30° से अजधक िहीं होिा चाजहए। परीिण के िौराि उपकरण चालू िहीं हो। िीचे जगरिे की ऊंचाई 50 एमएम िीचे जगरिे की संख्या (प्रत्येक 1 जिचले दकिारे पर) 6. प्रििवि परीिण (इलेजक्रकल, साधारण),– (1) रेजडयो फ्रीिेंसी प्रजतरिा परीिण,– सारणी 7. (i) जर्दकरजणत, आरएि, जर्द्यतु चम्ु बकीय ित्रे : बाधा परीिण,– परीिण का उद्देश्य रेजडयो आर्ृजि जर्द्युत चुम्बकीय िेत्रों के संपकव में रहते हुए परीिण के अधीि उपकरण के अिुपालि का सत्यापि। (1) (2) संिेप में परीिण प्रदक्रया परीिण के अधीि उपकरण जर्द्युत चुम्बकीय िेत्रों के संपकव में ह ै जिसमें जिर्िवष्ट अपेजित िेत्र िजि स्ट्तर और जिर्िवष्ट मािक में पठरभाजषत ित्रे एकरूपता ह।ै[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 55 परीिण के अधीि उपकरण को संग्राहक तरंग िेत्र के संपकव म ें लाया िाएगा। फ़्रीिेंसी स्ट्र्ीप केर्ल रेजडयो आर्ृजि जसग्नल स्ट्तर को समायोजित करिे या यदि अपेजित हो तो रेजडयो आर्ृजि-ििरेटर, एम्पलीिायरों और एंटेिा को जस्ट्र्च करिे के जलए रुककर दकया िाएगा। िहां फ़्रीिेंसी रेंि र्ृजद्िील रूप से स्ट्र्ीप की िाती है, चरण का आकार पूर्वर्ती फ़्रीिेंसी माि के 1% स ेअजधक िहीं होिा चाजहए। प्रत्येक आर्ृजि पर आयाम सग्रं ाहक र्ाहक का िहरार् समय परीिण के अधीि उपकरण के प्रयोग और प्रजतदक्रया िेिे के जलए अपेजित समय स े कम िहीं होगा, लेदकि दकसी भी जस्ट्थजत म ें 0.5 सेकेंड स े कम िहीं होगा। अपेजित सबस े महत्र्पूण व आर्ृजियों (िैसे घ़िी आर्ृजियों) का अलग स ेजर्श्लेषण दकया िाएगा। (1) आर्ृजि रेंि 80 मेगाहर्टि व – 3 जगगाहर्टिव (2), (4) 26 मेगाहर्टि व – 3 जगगाहर्टिव (3) िील्ड की िमता 10 र्ी/एम मॉडुलि 80 % एएम, 1 केहर्टिव, साइि र्ेर् ठटप्पण (1) आमतौर पर, इि संर्ेिििील आर्ृजियों से परीिण के अधीि उपकरण द्वारा उत्सर्िवत आर्ृजियों की आिा की िा सकती ह।ै (2) यह परीिण केर्ल 80 मगे ाहर्टिव से ऊपर के परीिण स्ट्तर को जिर्िवष्ट करता ह।ै जिचली रेंि म ें आर्ृजियों के जलए संचाजलत रेजडयो आर्ृजि बाधा के जलए परीिण जर्जधयों को प्राथजमकता िी िाती ह ै (उपाबंध क. के पैरा 6 के उप-परै ा (1) का खंड (ii) िेख)ें । (3) परीिण के अधीि ऐसे उपकरण के जलए जिसमें उपाबंध क के पैरा 6 के उप-पैरा (1) के खंड (ii) म ें जिर्िष्टव परीिण को लाग ू करि े के जलए अपेजित केबप्लंग का अभार् ह,ै इस परीिण के जलए जिचली आर्ृजि सीमा (परै ा 6 के उप-पैरा (1) का खंड (i) िेखें) 26 मगे ाहर्टिव होगी (अन्य सभी मामलों में उपाबंध क के पैरा 6 के उप-पैरा (1) का खंड (i) और खंड (ii) िोिों लाग ूहोगा)। (4) आर्ृजि रेंि 26 मेगाहर्टिव - 80 मगे ाहर्टिव के जलए, परीिण प्रयोगिाला या तो उपाबंध क. के परै ा 6 के उप-पैरा (1) के खंड (i) के अिुसार या उपाबंध क. के परै ा 6 के उप-परै ा (1) के खंड (ii) के अिुसार परीिण कर सकती ह।ै ककंतु जर्र्ाि की जस्ट्थजत म,ें उपाबंध क. के परै ा 6 के उप-परै ा (1) के खंड (ii) के अिुसार पठरणाम मान्य होंगे। सारणी 8. (ii) सचं ाजलत रेजडयो-आर्जृ ि ित्रे : प्रभार् परीिण,– परीिण का उद्देश्य रेजडयो आर्ृजि जर्द्युत चुम्बकीय िेत्रों के संपकव में रहते हुए परीिण के अधीि उपकरण के अिुपालि का सत्यापि। (1) (2) संिेप में परीिण प्रदक्रया रेजडयो आर्ृजि इलेक्रो-मैग्नेठटक करंट, इलेक्रो-मग्नै ेठटक फील्ड के प्रभार् का अिुकरण करते हुए, संिर्भवत मािक में पठरभाजषत कपप्लगं /जडकॉउप्लगं उपकरणों का उपयोग करके परीिण के अधीि उपकरण के पार्र पोटव और इिपुट/ऑउटपुट पोटव में िो़िा या इंिेक्ट दकया िाएगा। रेजडयो आर्ृजि ििरेटर, (डी-)कपप्लंग जडर्ाइस, एटेन्यूएटसव इत्यादि से युि परीिण उपकरण के प्रिििव को सत्याजपत दकया िाएगा। आरएि एम्प्लीट्यडू (50 Ω ) 10 र्ी (ई.एम.एि.)56 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] आर्ृजि रेंि 0.15 – 80 मगे ाहर्टि व मॉडुलि 80 % एएम, 1 केहर्टिव, साइि र्ेर् ठटप्पण (1) यह परीिण तब लागू िहीं होता िब परीिण के अधीि उपकरण में कोई मुख्य जबिली आपूर्त व या अन्य तांबे के तार र्ाला इिपुट/आउटपुट पोटव ि हो। (2) यदि परीिण के अधीि उपकरण म ें कई जडर्ाइस िाजमल हैं, तो परीिण केबल के प्रत्येक िोर पर दकया िाएगा यदि िोिों जडर्ाइस परीिण के अधीि उपकरण का भाग ह।ैं (3) आर्ृजि रेंि 26 मेगाहर्टिव - 80 मगे ाहर्टिव के जलए, परीिण प्रयोगिाला या तो उपाबंध क. के परै ा 6 के उप-पैरा (1) के खंड (i) के अिुसार या उपाबंध क. के परै ा 6 के उप-परै ा (1) के खंड (ii) के अिुसार परीिण कर सकती ह।ै लेदकि जर्र्ाि की जस्ट्थजत म,ें उपाबंध क. के पैरा 6 के उप-पैरा (1) के खंड (ii) के अिुसार पठरणाम मान्य होंगे। सारणी 9. (2) इलक्े रोस्ट्टैठटक जडस्ट्चाि:व बाधा परीिण परीिण का उद्देश्य परीिण के अधीि उपकरण के आस-पास म ें ऐसे जडस्ट्चाि व के परीिण के अधीि उपकरण पर इलेक्रोस्ट्टैठटक चािव र्ाली र्स्ट्तुओं या व्यजियों के जडस्ट्चािव के सीध े संपकव के मामल े में अिुपालि का सत्यापि। (1) (2) संिेप में परीिण प्रदक्रया संिर्भवत मािक में पठरभाजषत एक इलेक्रो स्ट्टैठटक जडस्ट्चािव ििरेटर का उपयोग दकया िाएगा और परीिण सेटअप इस मािक म ें जिर्िवष्ट आयामों, प्रयिु सामजग्रयों और ितों का अिुपालि करेगा। परीिण िुरू करिे से पहल,े ििरेटर के अिुपालि का सत्यापि दकया िाएगा। परीिण के अधीि उपकरण पर प्रत्येक पूर्व-चयजित जडस्ट्चािव स्ट्थाि पर कम से कम 10 जडस्ट्चािव प्रयिु दकए िाएगं े। क्रजमक जडस्ट्चािव के बीच का समय अंतराल कम स े कम 1 सेकंड होिा चाजहए। ग्राउंड टर्मविल से सुसजित िहीं होिे र्ाले परीिण के अधीि उपकरण के जलए, ईएसडी ििरेटर का उपयोग करके प्रयोज्य जडस्ट्चाि व के बीच परीिण के अधीि उपकरण को पूरी तरह से जडस्ट्चािव दकया िाएगा। कॉन्टैक्ट जडस्ट्चाि व पसंिीिा परीिण जर्जध ह।ै एयर जडस्ट्चािव कम पुिरुत्पादित होत े ह ैं और इसजलए इसका उपयोग केर्ल र्हीं दकया िाएगा िहां कॉन्टैक्ट जडस्ट्चािव प्रयुि िहीं दकया िा सकता ह।ै प्रत्यि प्रयोग: प्रर्ाहकीय सतहों पर दकए िाि े र्ाले कॉन्टैक्ट जडस्ट्चािव मोड में, इलेक्रोड परीिण के अधीि उपकरण के संपकव में होगा। इंसुलेटेड सतहों पर एयर जडस्ट्चािव मोड में, इलेक्रोड को परीिण के अधीि उपकरण के पास लाया िाता ह ैऔर स्ट्पाकव द्वारा जडस्ट्चािव होता ह।ै अप्रत्यि प्रयोग: जडस्ट्चािव को कॉन्टैक्ट मोड म ें परीिण के अधीि उपकरण के आसपास लग े कपप्लगं प्लेन्स पर लगाया िाता ह।ै[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 57 परीिण र्ोल्टेि कॉन्टैक्ट जडस्ट्चािव (1) 6 केर्ी एयर जडस्ट्चािव (1) 8 केर्ी ठटप्पण (1) कॉन्टैक्ट जडस्ट्चािव प्रर्ाहकीय सतहों पर लगाए िाएंगे। एयर जडस्ट्चािव को गैर-प्रर्ाहकीय सतहों पर प्रयिु दकया िाएगा। सारणी 10. (3) जसग्नल, डेटा और कंरोल लाइिों पर बस्ट्टव (िजणक): बाधा परीिण,– परीिण का उद्देश्य उि जस्ट्थजतयों के जलए परीिण के अधीि उपकरण के अिुपालि का सत्यापि िहा ं इलेजक्रकल बस्ट्टव को इिपुट/ऑउटपुट और कम्यूिकेिि पोर्टसव पर लगाया िाता है। (1) (2) संिेप में परीिण प्रदक्रया संिर्भवत मािक में पठरभाजषत बस्ट्टव ििरेटर का उपयोग दकया िाएगा। परीिण के अधीि उपकरण को िो़ििे स े पहल े ििरेटर की जर्िेषताओं को सत्याजपत दकया िाएगा। परीिण में र्ोल्टेि स्ट्पाइक्स के जर्स्ट्िोटों के संपकव में आिा िाजमल ह ै जिसके जलए आर्गे ों की पुिरार्ृजि आर्ृजि और 50 Ω और 1,000 Ω लोड पर आउटपुट र्ोल्टेि के जिखर माि िाजमल ह।ैं परीिण के अधीऩ उपकरण को िो़िि े स े पहले ििरेटर की जर्िेषताओं को सत्याजपत दकया िाएगा। ब्रस्ट्ट की सकारात्मक और िकारात्मक िोिों ध्रुर्ताएं प्रयिु की िाएंगी। परीिण की अर्जध प्रत्येक आयाम और ध्रुर्ता के जलए 1 जमिट से कम िहीं होगी। इिपुट/ऑउटपुट और कम्यूिकेिि लाइिों में बस्ट्टव के कपप्लंग के जलए, मािक म ें पठरभाजषत कैपेजसठटर् कपप्लंग क्लैंप का उपयोग दकया िाएगा। माप समय के िौराि परीिण पल्सों को लगातार प्रयिु दकया िाएगा। परीिण र्ोल्टेि एम्प्लीट्यूड (पीक र्ल्ै य)ू 1 केर्ी पुिरार्तवि आर्ृजि 5 केहर्टिव सारणी 11. (4) जसग्नल, डेटा और कंरोल लाइिों पर सि:व बाधा परीिण,– परीिण का उद्देश्य उि जस्ट्थजतयों के िौराि अिुपालि का सत्यापि िहां जर्द्युत सिव इिपुट/ऑउटपुट और कम्यूिकेिि पोर्टसव पर लगाए िाते ह।ैं (1) (2) संिेप में परीिण प्रदक्रया सिव ििरेटर का उपयोग दकया िाएगा। परीिण के अधीि उपकरण को िो़ििे स े पहले ििरेटर की जर्िेषताओं को सत्याजपत दकया िाएगा। परीिण म ें उिालों के संपकव को िाजमल दकया िाता है, जिसके जलए र्ृजद् समय, पल्स चौ़िाई, उच्च/जिम्न प्रजतबाधा भार पर आउटपुट र्ोल्टेि/धारा के जिखर माि और िो क्रजमक पल्सों के बीच न्यूितम समय अंतराल को यहां जिर्िवष्ट दकया िाता ह।ै कम से कम 3 सकारात्मक और 3 िकारात्मक सिव प्रयिु दकए िाएंगे। लागू इंिेक्िि िेटर्कव उस र्ायटरंग के प्रकार पर जिभवर करता ह ैजिसमें सिव को िो़िा गया है, िैसा दक यहां जिर्िवष्ट दकया गया ह।ै माप समय के िौराि परीिण पल्सों को लगातार प्रयिु दकया िाएगा।58 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] परीिण र्ोल्टेि असमजमत रेखाए ाँ लाईि स ेलाईि: 0.5 लाईि स ेभूतल : 1.0 केर्ी केर्ी समजमत रेखाए ाँ लाईि स ेलाईि: एिए लाईि स ेभूतल: 1.0 केर्ी पठररजित इिपुट/ऑउटपुट लाईि स ेलाईि: एिए लाईि स ेभूतल: 0.5 केर्ी और कम्यूिकेिि लाइि ें 7. अिपु ालि परीिण (जर्द्यतु , मिे पॉर्र),– सारणी 12. (1) डीसी मख्ु य र्ोल्टेि जभन्नता: प्रभार् परीिण,– परीिण का उद्देश्य उच्चतम और जिम्नतम सीमा के बीच डीसी मेि िेटर्कव पठरर्तवि की जस्ट्थजतयों के िौराि अिुपालि का सत्यापि। (1) (2) संिेप में परीिण प्रदक्रया परीिण म ें तापमाि जस्ट्थरता प्राप्त करिे पर और बाि में अपेजित माप करिे के जलए पयावप्त अर्जध के जलए जिर्िवष्ट जबिली आपूर्तव की जस्ट्थजत का परिॉमेंस िाजमल ह।ै जसर्ेठरटी परीिण उच्चतम सीमा डीसी स्ट्तर ह ै जिस पर परीिण के अधीि उपकरण क्लेम दकया िाता ह ै और यह साजबत होता ह ै दक उच्च-स्ट्तरीय जस्ट्थजतयों का स्ट्र्चाजलत रूप स े पता लगािे के जलए इसका जिमाणव दकया गया ह।ै जिम्नतम सीमा डीसी स्ट्तर ह ै जिस पर परीिण के अधीि उपकरण को क्लेम दकया िाता ह ै और यह साजबत होता ह ै दक जिम्न स्ट्तर की जस्ट्थजतयों का स्ट्र्चाजलत रूप स े पता लगाि े के जलए इसका जिमावण दकया गया ह।ै उपकरण िो स्ट्तरों के बीच आपर्ू तव र्ोल्टेि स्ट्तर पर जिर्िवष्ट अजधकतम अिुमेय त्रुठट का अिुपालि करेगा सारणी 13. (2) एसी मख्ु य र्ोल्टेि जभन्नता: प्रभार् परीिण,– परीिण का उद्देश्य उच्चतम और जिम्नतम सीमा के बीच एसी मेि िेटर्कव र्ोल्टेि पठरर्तवि की जस्ट्थजतयों के िौराि अिुपालि का सत्यापि। (1) (2) संिेप में परीिण प्रदक्रया परीिण में तापमाि जस्ट्थरता प्राप्त करि े और अपेजित माप करि े के जलए पयावप्त अर्जध के जलए जिर्िष्टव जबिली की जस्ट्थजत का अिुपालि िाजमल ह।ै मेन्स र्ोल्टेि (1), (2) उच्चतम सीमा U + 10 % nom जिम्नतम सीमा U – 15 % nom ठटप्पण (1) तीि-िेि जबिली आपूर्तव के मामले में, र्ोल्टेि जभन्नता प्रत्यके चरण के जलए क्रजमक रूप से लागू होगी। (2) यू का माि मापक यंत्र पर अंदकत होता ह।ै यदि कोई सीमा जिर्िवष्ट ह,ै तो "-" न्यूितम माि से संबंजधत ह ैऔर "+" श्रेणी के उच्चतम माि से सबं ंजधत ह।ै[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 59 सारणी 14. (3) एसी मिे र्ोल्टेि म ेंजगरार्ट और िोटी रुकार्टें: बाधा परीिण,– परीिण का उद्देश्य कम समय के मेि र्ोल्टेि कटौती की जस्ट्थजतयों के िौराि अिपु ालि का सत्यापि। (1) (2) संिेप में परीिण प्रदक्रया एक परीिण ििरेटर का उपयोग दकया िािा ह ै िो अपेजित समय के जलए एसी मिे र्ोल्टेि के एजम्प्लट्यडू को कम करिे के जलए उपयुि ह।ै परीिण के अधीि उपकरण को िो़ििे से पहले परीिण ििरेटर के परिॉमेंस को सत्याजपत दकया िाएगा। मेि र्ोल्टेि कटौती परीिणों को परीिणों के बीच कम से कम 10 सेकंड के अंतराल के साथ 10 बार िोहराया िािा चाजहए। माप समय के िौराि परीिण पल्सों को लगातार प्रयिु दकया िाएगा। परीिण (1, 2) परीिण परीिण परीिण परीिण घ परीिण इकाई क ख ग ़ि र्ोल्टेि में कटौती कटौती 0 0 40 70 80 % अर्जध 0.5 1 10/12(1) 25/30 (2) 250/300(1) cycles ठटप्पण (1) ये माि क्रमिः 50 हर्टजव/60 हर्टजव के जलए ह।ैं (2) सभी 5 परीिण (क, ख, ग, घ और ़ि) लाग ूह;ैं यह संभर् ह ैदक कोई भी परीिण जर्िल हो िाए िबदक अन्य परीिण पास हो िाएं। सारणी 15. (4) डीसी मिे पार्र बाधा टेस्ट्ट पर र्ोल्टेि म ेंजगरार्ट, िोटी रुकार्टें और र्ोल्टेि जभन्नता,– परीिण का उद्देश्य डीसी मेि र्ोल्टेि जडप्स, बिलार् और कम समय की कटौती की जस्ट्थजतयों के िौराि अिुपालि का सत्यापि। (1) (2) संिेप में परीिण प्रदक्रया एक परीिण ििरेटर का उपयोग दकया िाएगा। परीिण िुरू करि े से पहले, ििरेटर की परिॉमेंस जर्िेषताओं को सत्याजपत दकया िाएगा। प्रत्येक परीिण घटिा के बीच तीि जडप्स/रुकार्टों के अिुक्रम और कम से कम 10 सेकंड के अतं राल का उपयोग करके, परीिण के अधीि उपकरण को एजम्प्लट्यूड और अर्जध के प्रत्येक चयजित संयोिि के जलए र्ोल्टेि जडप्स और िोटी रुकार्टों के संपकव में लाया िाएगा। प्रत्येक जिर्िवष्ट र्ोल्टेि जभन्नता के जलए परीिण के अधीि उपकरण के सबसे साधारण ऑपरेटटंग मोड का 10 सेकंड के अंतराल पर तीि बार परीिण दकया िाएगा। यदि परीिण के अधीि उपकरण एक एकीकृत उपकरण ह,ै तो माप समय के िौराि परीिण पल्सों को लगातार प्रयिु दकया िाएगा। जसर्ेठरटी स्ट्तर परीिण जिम्नजलजखत स्ट्तर लाग ू होंग:े इकाई र्ोल्टेि एम्प्लीट्यूड 40 और 70 रेटेड र्ोल्टेि का % जडप्स अर्जध(1) 10; 30; 100 ms िॉटव इंटरप्सि परीिण उच्च प्रजतबाधा और/या जिम्न60 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (4) जस्ट्थजत प्रजतबाधा एम्प्लीट्यूड 0 रेटेड र्ोल्टेि का % अर्जध(1) 1; 3; 10 ms र्ोल्टेि र्ैठरएिि एम्प्लीट्यूड 85 और 120 रेटेड र्ोल्टेि का % अर्जध(1) 0.1; 0.3; 1; 3; 10 s ठटप्पण (1) सभी अंतरालों का परीिण दकया िािा है सारणी 16. (5) एसी और डीसी मिे बस्ट्ट व(िजणक): बाधा परीिण,– परीिण का उद्देश्य उि जस्ट्थजतयों के िौराि अिुपालि का सत्यापि िहां इलेजक्रकल ब्रस्ट्ट मेिए र्ोल्टेि पर आरोजपत होते ह।ैं (1) (2) संिेप में परीिण प्रदक्रया बस्ट्टव ििरेटर का उपयोग दकया िाएगा। परीिण के अधीि उपकरण को िो़िि े स े पहले ििरेटर की जर्िेषताओं को सत्याजपत दकया िाएगा। परीिण म ें र्ोल्टेि स्ट्पाइक्स के बस्ट्टव का िोजखम िाजमल ह ै जिसके जलए 50 Ω और 1 000 Ω लोड पर आर्ेगों की पिु रार्ृजि दफ्रिेंसी और आउटपुट र्ोल्टेि के चरम मल्ू यों को संिर्भवत मािक में पठरभाजषत दकया गया ह।ै बस्ट्टव की सकारात्मक और िकारात्मक िोिों ध्रुर्ताएं प्रयिु की िाएंगी। परीिण की अर्जध प्रत्येक एम्प्लीट्यडू और ध्रुर्ता के जलए 1 जमिट से कम िहीं होगी। मेि पर इंिेक्िि िेटर्कव म ें बस्ट्टव ऊिा व को मेि में िष्ट होि े से रोकिे के जलए ब्लॉककंग दिल्टर होि े चाजहए। माप समय के िौराि परीिण पल्सों को लगातार प्रयिु दकया िाएगा। एम्प्लीट्यूड (पीक र्ल्ै य)ू 2 केर्ी पुिरार्ृजि िर 5 केहर्टिव सारणी 17. (6) मिे एसी और डीसी पर सि:व बाधा परीिण,– परीिण का उद्देश्य उि जस्ट्थजतयों के िौराि अिुपालि का सत्यापि िहां इलेजक्रकल सिव मिे र्ोल्टेि पर आरोजपत होते ह।ैं (1) (2) संिेप में परीिण प्रदक्रया सिव ििरेटर का उपयोग दकया िाएगा। परीिण के अधीि उपकरण को िो़िि े स े पहले ििरेटर की जर्िेषताओं को सत्याजपत दकया िाएगा। परीिण में जर्द्युतीय सिव के संपकव में आिा िाजमल ह ै जिसके जलए र्ृजद् समय, पल्स चौ़िाई, उच्च/जिम्न प्रजतबाधा भार पर आउटपुट र्ोल्टेि/र्तवमाि के जिखर माि और िो क्रजमक पल्स के बीच न्यूितम समय अंतराल िाजमल ह।ै[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 61 कम से कम 3 सकारात्मक और 3 िकारात्मक सिव प्रयिु दकए िाएंगे। एसी मुख्य आपूर्त व लाइिों पर, सिव एसी आपूर्तव आर्ृजि के साथ समकाजलक होंग े और इस तरह िोहराए िाएंग े दक 0°, 90°, 180° और 270° के सभी 4 चरण जिफ्टों पर मेि दफ्रिेंसी के साथ सिव का इंिेक्िि कर्र हो िाए। इंिेक्िि िेटर्कव सर्कवटरी उि प्रयोज्य कंडक्टरों पर जिभवर करती ह ै जििमें सिव को िो़िा िाता ह।ै माप समय के िौराि परीिण पल्स को लगातार प्रयिु दकया िाएगा। परीिण र्ोल्टेि लाईि स ेलाईि: 1.0 केर्ी लाईि स ेभूतल: 2.0 केर्ी सारणी 18. (7) डीसी मिे पार्र ठरपल,– परीिण का उद्देश्य उि जस्ट्थजतयों के िौराि अिुपालि का सत्यापि िहां इलेजक्रकल सिव मिे र्ोल्टेि पर आरोजपत होते ह।ैं (1) (2) संिेप में परीिण प्रदक्रया एक परीिण ििरेटर का उपयोग दकया िाएगा। परीिण िरूु करिे से पहले, ििरेटर के अिुपालि को सत्याजपत दकया िाएगा। परीिण म ें परीिण के अधीि उपकरण को ठरपल र्ोल्टेि के अधीि करिा िाजमल ह ै िैसे दक पारंपठरक रेजक्टिायर जसस्ट्टम या डीसी जबिली आपूर्तव स्रोतों पर ओर्रलेइंग सहायक सेर्ा बैटरी चािवर द्वारा उत्पन्न र्ोल्टेि। ठरपल र्ोल्टेि की दफ्रिेंसी प्रयोज्य पॉर्र दफ्रिेंसी या उसके गुणक (2, 3 या 6) ह,ै िो मेि के जलए उपयोग दकए िािे र्ाले रेजक्टिायर जसस्ट्टम पर जिभवर करती ह।ै परीिण ििरेटर के आउटपुट पर ठरपल के तरंगरूप म ेंएक साइिसॉइड लाइिर कैरेक्टर होता ह।ै परीिण को कम से कम 10 जमिट या परीिण के अधीि उपकरण के पठरचालि अिुपालि के पूणव सत्यापि की अिुमजत िेिे के जलए अपेजित समय अर्जध के जलए प्रयुि दकया िाएगा। िाममात्र डीसी र्ोल्टेि का 2 प्रजतित (1) ठटप्पण (1) परीिण स्ट्तर एक पीक-टू-पीक र्ोल्टेि ह ै जिस े िाममात्र डीसी र्ोल्टेि के प्रजतित के रूप में व्यि दकया िाता ह।ै (2) यह परीिण जस्ट्र्च मोड कन्र्टवसव को िाजमल करिे र्ाले बैटरी चािवर जसस्ट्टम से िु़िे उपकरणों पर प्रयुि िहीं होता ह।ै 8. अिपु ालि परीिण (बटै री चाजलत उपकरण),– सारणी 19 क.8 आतं ठरक बटै री का कम र्ोल्टेि (मिे पॉर्र स ेि़िु ा िहीं): प्रभार् परीिण,– परीिण का उद्देश्य कम बैटरी र्ोल्टेि जस्ट्थजतयों के िौराि अिुपालि का सत्यापि। (1) (2) संिेप में परीिण प्रदक्रया परीिण में तापमाि जस्ट्थरता प्राप्त करि े और अपेजित माप करि े के जलए पयावप्त अर्जध के िौराि जर्जिष्ट जिम्न बैटरी स्ट्तर की जस्ट्थजत में परीिण के अधीि उपकरण का62 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] एक्सपोिर िाजमल ह।ै बैटरी की अजधकतम आंतठरक प्रजतबाधा और न्यूितम बैटरी आपूर्तव र्ोल्टेि स्ट्तर (U ) उपकरण के जर्जिमावता द्वारा जिर्िवष्ट दकया िािा ह।ै bmin र्ैकजल्पक जबिली आपूर्तव स्रोत िैसे दक बेंच परीिण का उपयोग करके बैटरी का अिुकरण करि े के मामले म,ें जिर्िवष्ट प्रकार की बैटरी की आतं ठरक प्रजतबाधा का भी अिुकरण दकया िाएगा। र्ैकजल्पक जबिली आपूर्तव प्रयोज्य आपूर्त व र्ोल्टेि पर पयावप्त करंट िेि ेमें सिम होगी। परीिण क्रम इस प्रकार ह:ै - जबिली की आपूर्तव को रेटेड पठरचालि जस्ट्थजतयों के अिुसार पठरभाजषत र्ोल्टेि पर जस्ट्थर होिे ि ेंऔर माप या लोप्डंग जस्ट्थजत प्रयिु करें। - अजभलेख: (क) तारीख, समय और पयावर्रणीय जस्ट्थजतयों सजहत र्ास्ट्तजर्क माप जस्ट्थजतयों को पठरभाजषत करि े र्ाला डेटा, (ख) र्ास्ट्तजर्क जबिली आपूर्तव र्ोल्टेि। माप करें और त्रुठटयों तथा अन्य सुसंगत अिपु ालि मापिंडों को ठरकॉडव करें। (क) अपेिाओं के अिुपालि की पुजष्ट करें (ख) उपरोि प्रदक्रया को यूबीजमि पर र्ास्ट्तजर्क आपूर्त व र्ोल्टेि के साथ िोहराए ं और दिर 0.9 यूबीजमि पर िोहराएं (ग) अपेिाओं के अिुपालि की पुजष्ट करें। बैटरी की अजधकतम आंतठरक प्रजतबाधा उपकरण के जर्जिमावता द्वारा जिर्िवष्ट की िािी ह।ै र्ोल्टेि की जिम्नतम सीमा सबसे कम र्ोल्टेि जिस पर उपकरण जर्जििेिों के अिुसार िीक से काम करता ह।ै चक्रों की संख्या प्रत्येक कायावत्मक मोड के जलए कम से कम एक परीिण चक्र। उपाबधं ख: प्रर्ाह बाधा परीिण (आज्ञापक) 1. साधारण,– (1) इस उपाबंध में जिर्िष्टव परीिण र्ायुमंडलीय िबार् में हर्ा के साथ 0.25 Q , 0.4 Q और Q की प्रर्ाह िर max max max पर दकया िाएगा। र्ैकजल्पक रूप से, एक परीिण गैस मीटर की िबार् सीमा के भीतर िबार् पर उपयुि गैस के साथ करिा होगा। (2) यदि गैस मीटर के प्रकार का जडजाइि सभी पाइप आकारों के जलए समाि है, तो यह एक ही आकार पर परीिणों का पूरा सेट करिे के जलए पयावप्त ह ैजिसे मीटर र्ग वके जलए सबसे खराब जस्ट्थजत मािा िाता ह।ै यदि अपेजित समझा िाए तो अन्य आकारों पर भी परीिण दकया िािा चाजहए। 2. मध्यम प्रर्ाह बाधा,– (1) प्रर्ाह बाधा परीिण प्रत्येक प्रयोज्य पाइप्पगं कॉजन्फगरेिि का उपयोग करके जिष्पादित दकया िाएगा िैसा दक सारणी ख.1 में प्रस्ट्ततु दकया गया ह,ै मीटर के अपस्ट्रीम पर लगाया गया है, जिसे मीटर जर्जिमावता के माउंटटंग जर्जििेिों के अिुसार संस्ट्थाजपत दकया गया ह।ै[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 63 (2) सारणी ख.1 म ें परीिण ितें ङ, च और ि उि गैस मीटरों पर लागू िहीं होती ह ैं जििका उपयोग आर्ासीय िेत्रों म ें दकया िािा ह।ै सारणी ख.1 में अन्य सभी परीिण ित ें पयावर्रण (आर्ासीय और गैर-आर्ासीय िोिों) की परर्ाह दकए जबिा लाग ूहोती ह।ैं (3) उपाबंध ख. के पैरा 2 के उप-पैरा (1) म ें जर्जिर्िवष्ट प्रत्येक परीिण के िौराि गैस मीटर के त्रुठट र्क्र का बिलार् परै ा 4 के उप-परै ा (13) के खंड (iii) म ेंजर्जिर्िवष्ट अपेिा को पूरा करेगा। अपेिाओं को परू ा करि े के जलए जर्जिमावता के जर्जििेिों के अिुसार फ्लो कंडीििर का उपयोग दकया िा सकता ह।ै ऐसे मामले में फ्लो कंडीििर को मॉडल अिुमोिि प्रमाणपत्र म ेंजिर्िवष्ट दकया िाएगा। (4) यदि उपाबंध ख. के पैरा 2 के उप-परै ा (3) में जर्जिर्िवष्ट अपेिा को परू ा करिे के जलए सीधे अपस्ट्रीम पाइप्पंग एलजमि की एक जर्जिष्ट न्यूितम लंबाई अपेजित है, तो इस एलजमि को परीिणों के िौराि प्रयुि दकया िाएगा और इसका मूल्य मॉडल अिुमोिि प्रमाणपत्र में जिर्िवष्ट होगा। (5) अल्रासोजिक गैस मीटरों के जलए पैरा 4 के उप-पैरा (13) के खंड (iii) में जर्जिर्िवष्ट अपेिाओं को भी परू ा दकया िाएगा िब उपाबंध ख के परै ा 2 के उप-पैरा (1) म ें जर्जिर्िवष्ट प्रत्येक परीिण के जलए सीध े अपस्ट्रीम पाइप्पगं एलजमि की न्यिू तम लंबाई में अजतठरि 10 डी सीध े पाइप की लंबाई िो़िी िाएगी। 3. गभं ीर प्रर्ाह बाधा,– (1) गंभीर बाधा परीिणों के जलए सारणी ख.1 म ें जिर्िवष्ट पाइप का जर्न्यास ग और घ का उपयोग अजतठरि आध े पाइप िेत्र प्लेट के साथ दकया िाएगा, प्रयोज्य परीिण पाइप का जर्न्यास और इस पहल े मो़ि के बाहरी जत्रज्या की ओर अधव-चंद्र के खुल े िो़ि के साथ पहल े मो़ि के बाि अपस्ट्रीम संस्ट्थाजपत दकया गया ह,ै जिसे सारणी ख.1 में + के रूप म ें दिखाया गया ह ै। (2) उपाबंध ख के पैरा 2 के उप-पैरा (2), (3), (4) और (5) के उपबंध तििुसार लाग ूहोते ह।ैं सारणी ख.1. प्रर्ाह म ेंबाधा के जलए पाइप का जर्न्यास पाइप का परीिण परीिण पठरजस्ट्थजत ठटप्पण क स जर्न्यास ि इ ि जॉस ाम ल स ाब र ट ार ल् अ मव थ क् ेट ॉर् (1) (2) (3) (4) (5) (6) (7) (8) लगभग 80 डी सीधी लाइि × × × (क) संिभव पठरजस्ट्थजत लगभग 10 डी सीधी लाइि × (िोट िेख)ें64 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (ख) एक एकल 90° मो़ि रेजडयस एलबो: 1.5 डी × × × × रोटेटटंग राईट समलत मो़ि म ेंसे िोहरा मो़ि (ग) × × × × रेजडयस एलबो : 1.5 डी रोटेटटंग लेफ्ट; (घ) समलत मो़ि म ेंसे िोहरा मो़ि × × × × रेजडयस एलबो :1.5 डी पाइप व्यास का एक किम अतं र (ङ) एक्सपैंडर × × × लाग ूदकया िाता ह ै जर्स्ट्तार/कमी भाग का कोण: ≤ 15° (च) ठरड्यूिर × × × अपस्ट्रीम फ्लन्ि पर डायामीटर लगभग +3 % (ि) × × × स्ट्टेप और –3 % िजर् पाइप्पंग में पहला मो़ि और + हाल्ि पाइप एठरया प्लेट अधवचन्द्राकार प्लेट की संस्ट्थापिा × × दिखाती ह ै ठटप्पण: दकसी भी टरबाइि मीटर को अपस्ट्रीम जहस्ट्से म ें फ्लो डायरेक्टर (स्ट्रेटिर और िोि कोि) स े लैस करि े की अपेिा होगी। इस कारण स ेअपस्ट्रीम भाग को 10 डी माि स ेपरे एक सीधी रेखा के साथ जर्स्ट्ताठरत करिे का प्रभार् िगण्य होगा। उपाबधं ग: जर्जभन्न मीटटरंग जसद्ातं ों के जलए अपिे ाओं और प्रयोज्य परीिणों का अर्लोकि (आज्ञापक) 1. साधारण,– यह उपाबंध कई अलग-अलग मीटटरंग जसद्ांतों के जलए िरूरी अपेिाओं और प्रयोज्य परीिणों को ििावता ह।ै यह अपेिाएाँ सभी मीटटरंग जसद्ांतों पर लाग ू होती ह।ैं संबंजधत परीिण करिे की िरुरत अपेिा में जर्जिर्िवष्टािुसार घटिा के प्रजत ऐसे भौजतक मीटटरंग जसद्ांत की संर्ेिििीलता पर जिभवर करती ह।ै दकसी परीिण को केर्ल तभी िो़िा िाएगा िब घटिा के प्रजत मापि जसद्ांत की असंर्ेिििीलता का स्ट्र्तंत्र, अंतरराष्ट्रीय स्ट्तर पर स्ट्र्ीकृत और प्रकाजित साक्ष्य मौिूि हो। उि मीटटरंग जसद्ांतों के जलए िो सारणी म ें सूचीबद् िहीं हैं, प्रत्येक परीिण की प्रयोज्यता जिधावठरत की िाएगी। सारणी ग.1 में डायाफ्राम गैस मीटर, टेम्प्रेचर कंपिसेटेड (टीसी) डायाफ्राम गैस मीटर, रोटरी जपस्ट्टि गैस मीटर और टरबाइि गैस मीटर को जर्िुद् मैकाजिकल मीटर मािा िाता ह।ै यदि इि मैकाजिकल मीटरों में इलेक्रॉजिक्स, सॉफ्टर्ेयर और/या सहायक उपकरण िो़िे िाते ह,ैं तो इलेक्रॉजिक्स, सॉफ्टर्ेयर और/या सहायक उपकरणों पर परीिण भी लाग ूहोते ह।ैं[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 65 सारणी ग.1. जर्जभन्न मीटटरंग जसद्ांतों के जलए अपेिाओं और प्रयोज्य मूल्यांकि परीिणों का अर्लोकि मूल्यांकि जर्षय ि अ खप ंडेि ा परीिण खंड म ा फ्र ा य ा ड ट स्ट् प ज ी र ट ो र ि इ ा ब र क ि ज ॉ स ा र ल् स ल ज ो य र ठ ॉ क स ॉम ल मव थ स क् ेट ॉ र् ट अ (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) पैरा 11 का जडिाइि जिरीिण पैरा 5 उप-पैरा (3) × × × × × × × पैरा 4 का × × × × × × × उप-पैरा (3), पैरा 11 के पैरा 4 का उप-पैरा (6) त्रूठट उप-पैरा (4) का खंड (i) पैरा 11 के पैरा 4 का उप-पैरा (6) ठरप्रोड्यूजसबीजलटी उप-पैरा (6) का खंड (ii) × × × × × × × पैरा 11 के पैरा 4 का उप- उप-पैरा (6) ठरजपटेटबीजलटी पैरा (7) का खंड(iii) × × × × × × × पैरा 4 के उप- पैरा 11 के पैरा (13) का उप-पैरा (6) ओठरएंटेसि खंड (i) का खंड (iv) - × × - × - - पैरा 4 के उप- पैरा 11 के पैरा (13) का उप-पैरा (6) फ्लो डारेक्िि खंड (ii) का खंड (v) - × × × × - - पैरा 11 के पैरा 4 का उप-पैरा (6) र्र्किंग प्रेिर उप-पैरा(8) का खंड (vi) - × × × × × × पैरा 11 के पैरा 4 का उप-पैरा (6) तापमाि उप-पैरा (9) का खंड (vii) × × × × × × × पैरा 4 के उप-पैरा 11 के फ्लो बाधा - - × × - × × पैरा (13) का उप-पैरा (6)66 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] खंड (iii) का खंड(viii) यदि प्रयोज्य यदि पैरा 11 के हो प्रयोज्य हो पैरा 4 का उप-पैरा (6) ड्यूराबीजलटी उप-पैरा (10) का खंड(ix) × × × - - ड्राइर् िाफ्ट टेस्ट्ट पैरा 4 के उप- यदि यदि पैरा (13) का प्रयोज्य हो प्रयोज्य हो पैरा 11 के खंड उप-पैरा (6) (iv) का खंड (x) - - - - - (टॉकव) पैरा 11 के ओर्रलोड फ्लो पैरा 4 का उप-पैरा (6) टेस्ट्ट उप-पैरा (11) के खंड (xi) × × × - - - - जर्जभन्न गैस पैरा 4 के उप- पैरा 11 के पैरा (13) का उप-पैरा (6) खंड (v) का खंड (xi) × × × × × × × (यदि प्रयोज्य हो) कंपि और िॉक्स पैरा 11 के पैरा 4 का उप-पैरा (6) उप-पैरा (12) का खंड (xiii) × × × × × × × जर्जिमेय घटक पैरा 4 के उप- पैरा 11 के यदि यदि यदि पैरा (13) का उप-पैरा (6) प्रयोज्य हो प्रयोज्य हो प्रयोज्य हो खंड (vi) का खंड (xiv) - - - - पैरा 4 के उप- 0 + पैरा (13) का खंड (vii) - - - × × × × इलेक्राजिक्स उपाबंध -क पैरा 4 के उप-पैरा 11 के पैरा (13) का उप-पैरा (6) सहायक उपकरणों खंड (viii) का खंड (xvi) - - - × × × × से इलेक्रॉजिक्स का प्रभार् उपाबधं घ: गसै मीटरों के एक र्ग वमॉडल का अिमु ोिि[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 67 (आज्ञापक) 1. गसै मीटर के र्ग,व – यह उपाबंध यह तय करि े में जििेिक (जर्जधक मापजर्ज्ञाि) द्वारा लागू दकए िाि े र्ाल े माििडं ों का र्णिव करता ह ैदक क्या मॉडल अिुमोिि उद्देश्यों के जलए गैस मीटरों के समूह को एक ही र्गव से मािा िा सकता है, जिसके जलए मीटर आकार के केर्ल चयजित िमूिों का परीिण दकया िािा ह।ै 2. पठरभाषा,– मीटरों का एक र्गव जर्जभन्न आकारों या जर्जभन्न प्रर्ाह िर र्ाले गैस मीटरों का एक समूह है, जिसमें सभी मीटरों म ें जिम्नजलजखत जर्िेषताएं होंगी, अथावत:- (क) र्ही जर्जिमावता; (ख) गैस के संपकव में आि े र्ाले भागों की ज्याजमतीय समािता; (ग) र्ही मीटटरंग जसद्ांत; (घ) समाि सटीकता र्गव; (ङ) समाि तापमाि रेंि; (च) प्रत्येक मीटर आकार के जलए समाि इलेक्रॉजिक उपकरण; (ि) जडजाइि और घटक असेंबली का एक समाि मािक; (ि) उि घटकों के जलए समाि सामग्री िो मीटर के परिामेंस के जलए महत्र्पूण व हैं; (झ) मीटर आकार के सापेि समाि संस्ट्थापिा अपिे ाएाँ, उिाहरणाथ व मीटर के अपस्ट्रीम म ें सीध े पाइप का 10 डी (पाइप व्यास) और मीटर के डाउिस्ट्रीम म ेंसीधे पाइप का 5 डी। 3. मीटर चयि,– गैस मीटरों के र्ग व के दकस आकार का परीिण दकया िािा चाजहए, इस पर जर्चार करत े समय जिम्नजलजखत जियमों का पालि दकया िाएगा, अथातव :- (क) जििेिक (जर्जधक मापजर्ज्ञाि) परीिण म ें जर्िेष मीटर आकारों को िाजमल करि े और हटािे के कारणों की घोषणा करेगा; (ख) मीटरों के दकसी भी र्ग वमें सबसे िोटे मीटर का हमेिा परीिण दकया िाएगा; (ग) जिि मीटरों म ें एक र्ग व के भीतर सबसे चरम ऑपरेटटंग परै ामीटर हैं, उन्ह ेंपरीिण के जलए जर्चार दकया िाएगा, उिाहरण के जलए सबसे ब़िी प्रर्ाह िर सीमा, चलायमाि भागों की उच्चतम पठरधीय गजत, आदि; (घ) यदि व्यार्हाठरक हो, तो मीटरों के दकसी भी र्ग व म ें सबसे ब़िे मीटर का हमिे ा परीिण दकया िािा चाजहए। तथाजप, यदि सबसे ब़ि ेमीटर का परीिण िहीं दकया गया है, तो परीिण दकए गए सबसे ब़ि ेमीटर क्यूमैक्स> 2 × क्यूमैक्स र्ाल ेदकसी भी मीटर को संबंजधत र्गव का जहस्ट्सा िहीं मािा िाएगा; (ङ) स्ट्थाजयत्र् परीिण उि मीटरों पर लाग ूदकया िाएगा िहां सबसे अजधक जघसार् की आिंका ह;ै (च) माप रांसड्यूसर म ें जबिा जहलिे र्ाल े जहस्ट्सों र्ाले मीटरों के जलए, स्ट्थाजयत्र् परीिण के जलए सबसे िोटे आकार का चयि दकया िाएगा; (ि) प्रभार् मात्रा से संबंजधत सभी परिॉमेंस परीिण मीटरों के एक र्गव स ेएक आकार पर दकए िाएंगे; (ि) जचत्र घ.1 म ेंरेखांदकत र्गव की इकाईयों को परीिण के जलए एक उिाहरण मािा िा सकता ह ै (ठटप्पण: प्रत्येक पंजि एक र्ग वका प्रजतजिजधत्र् करती ह,ै मीटर 1 सबसे िोटा ह)ै ।68 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] 1 1 2 1 2 3 1 2 3 4 1 2 3 4 5 1 2 3 4 5 6 जचत्र घ.1: मीटर जपराजमड का र्ग व उपाबधं ङ: चयजित सत्यापि जर्जधयों का जर्र्रण 1. िस्ट्तार्जे ीकरण और जडजाइि का जर्जििेिि और सत्यापि (एडी),– (1) प्रयोग,– आधारभूत प्रदक्रया, सभी सॉफ़्टर्ेयर सत्यापि मल्ू यांकि के िौराि प्रयुि होती ह।ै (2) िस्ट्तार्ेजीकरण और जर्जििेि के जर्श्लेषण और जडिाइि के सत्यापि के जलए पूर् वितें,- यह प्रदक्रया मापिे र्ाल ेउपकरण के जर्जिमावता के िस्ट्तार्ेजीकरण पर आधाठरत ह।ै िस्ट्तार्ेज में जिम्नजलजखत िाजमल होंगे, अथावत:- (i) साधारण रूप म ें उपकरण के बाहरी रूप स े सुलभ कायों की जर्जिष्टता (जडस्ट्प्ल े को िो़िकर जबिा दकसी इंटरिेस र्ाल े सरल उपकरणों के जलए उपयुि, कायावत्मक परीिण द्वारा सत्यापि योग्य सभी सुजर्धाएं, धोखाध़िी का कम िोजखम); (ii) सॉफ्टर्ेयर काय व और इंटरफेस की जर्जिष्टता इंटरफेस र्ाल े उपकरणों के जलए और ऐस े उपकरण कायव के जलए अपेजित ह ैजििका कायावत्मक परीिण िहीं दकया िा सकता ह ै और धोखाध़िी के बढ़त े िोजखम के मामल े में। यह जर्र्रण उि सभी सॉफ़्टर्ेयर कायव को स्ट्पष्ट करेगा और व्याख्या करेगा िो मापजर्ज्ञाि सुजर्धाओं पर प्रभार् डाल सकते ह ैं (iii) इंटरिेस के संबंध में, िस्ट्तार्ेि में उि आििे ों या संकेतों की पूरी सूची िाजमल होगी जिन्ह ें सॉफ्टर्ेयर समझिे में सिम ह ैतथा प्रत्येक आिेि का प्रभार् जर्स्ट्तार से बताया िाएगा। जिस रीजत स ेउपकरण अप्रलेजखत आिेिों पर प्रजतदक्रया करता ह ैउसका र्णवि दकया िाएगा; (iv) यदि सॉफ़्टर्ेयर कायों को समझिे और उिका मल्ू यांकि करिे के जलए अपेजित हो, तो िठटल माप एल्गोठरिम, दक्रप्टोग्रादफक कायव, या महत्र्पूणव समय बाधाओं के जलए सॉफ़्टर्ेयर का अजतठरि िस्ट्तार्ेजीकरण प्रिाि दकया िाएगा; (v) िब दकसी सॉफ्टर्ेयर प्रोग्राम के कायव को मान्य करि े की प्रदक्रया स्ट्पष्ट िहीं ह,ै तो परीिण जर्जध जर्कजसत करि े का िाजयत्र् जर्जिमावता पर डाला िाएगा। इसके अजतठरि, प्रश्नों के उिर िेि े के उद्देश्य स े परीिक को प्रोग्रामर की सेर्ाएाँ उपलब्ध करायी िािी चाजहए।[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 69 िांच के जलए एक साधारण पर्ू व ितव िस्ट्तार्ेजीकरण की पणू वता और परीिण के अधीि उपकरण की स्ट्पष्ट पहचाि ह,ै अथावत् सॉफ्टर्ेयर पकै ेि िो मापजर्ज्ञाि कायों में योगिाि करते ह ैं। (3) जर्र्रण,– परीिण प्रयोगिाला पाठ्य और ग्रादिकल प्रस्ट्ततु ीकरण में र्णिव का उपयोग करके माप उपकरण के कायों और जर्िेषताओं का मल्ू यांकि करती ह ै और अपिे ाओं के अिुपालि के संबंध में जिणवय लते ी ह।ै मापर्ैज्ञाजिक अपेिाओं के साथ-साथ सॉफ्टर्ये र-कायावत्मक अपेिाओं (िैसे धोखाध़िी संरिण, समायोिि मापिंडों की सुरिा, अस्ट्र्ीकृत कायव, अन्य उपकरणों के साथ संचार, सॉफ्टर्ेयर का अद्यति, गलती का पता लगािा, आदि) पर जर्चार और मूल्यांकि दकया िािा चाजहए। (4) पठरणाम,– यह प्रदक्रया माप उपकरण की सभी जर्िेषताओं के जलए एक पठरणाम िेती है, परंत ु दक जर्जिमावता द्वारा उजचत िस्ट्तार्ेि प्रस्ट्ततु दकया गया हो। पठरणाम को सॉफ़्टर्ेयर मूल्यांकि ठरपोटव में सॉफ़्टर्ेयर से संबंजधत अिुभाग में प्रलेजखत दकया िािा चाजहए। (5) पूरक प्रदक्रयाएाँ,– यदि िस्ट्तार्ेज की िांच से प्रमाजणत सत्यापि पठरणाम िहीं जमल पाते हैं, तो अजतठरि प्रदक्रयाएं प्रयुि की िािी चाजहए। अजधकांि मामलों में "कायावत्मक परीिण द्वारा मापर्ैज्ञाजिक कायों को मान्य करिा" (ङ.2 िेख)ें एक पूरक प्रदक्रया ह।ै 2. मापजर्ज्ञाि कायों के कायावत्मक परीिण द्वारा सत्यापि (र्ीएिटीएम),– (1) प्रयोग,– रॉ डेटा स े माप मूल्य की गणिा करिे के जलए एल्गोठरिम की िुद्ता को सत्याजपत करि े के जलए, एक जर्िेषता के लाइिराइिेिि के जलए, पयावर्रणीय प्रभार्ों का मुआर्िा, मल्ू य गणिा में पूणाकिं ि, आदि। (2) पूर्व ित,ें – ऑपरेटटंग मैिअु ल, कायवप्रणाली पैटि,व मापजर्ज्ञाि संिभ वऔर परीिण उपकरण। (3) जर्र्रण,– अजधकांि मल्ू यांकि और परीिण जर्जधयााँ जर्जभन्न पठरजस्ट्थजतयों में संिभव माप पर आधाठरत होती ह।ैं उिका अिुप्रयोग उपकरण की एक जिजश्चत तकिीक तक ही सीजमत िहीं ह।ै तथाजप इसका उद्दश्े य मुख्य रूप स े सॉफ़्टर्ेयर को मान्य करिा िहीं ह,ै परीिण के पठरणामों की व्याख्या सॉफ़्टर्ेयर के कुि जहस्ट्सों के सत्यापि के रूप में की िा सकती ह,ै साधारणतया र्े िो मापर्ैज्ञाजिक रूप से सबसे महत्र्पूणव ह।ैं यदि परीिण उपकरण की सभी मापर्ैज्ञाजिक रूप के सुसगं त जर्िेषताओं को कर्र करते हैं, तो संबंजधत सॉफ़्टर्ेयर भागों को मान्य मािा िा सकता ह।ै साधारणतया, मापिे र्ाल े उपकरण की मापर्ैज्ञाजिक जर्िेषताओं को मान्य करिे के जलए कोई अजतठरि सॉफ़्टर्ेयर जर्श्लषे ण या परीिण लागू िहीं करिा प़िता ह।ै70 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (4) पठरणाम,– एल्गोठरिम की िुद्ता र्ैध या अमान्य ह।ै सभी पठरजस्ट्थजतयों में माप माि अजधकतम अिुज्ञेय त्रुटी के भीतर ह ैंया िहीं। (5) पूरक प्रदक्रयाएाँ,– यह जर्जध साधारणतः उपाबंध ङ के पैरा 1 का संर्द्िव ह।ै कुि मामलों म ें गजतिील माप के जलए सोसव कोड (उपाबंध ङ के परै ा 5 म ें जर्जिर्िवष्टािुसार) के आधार पर या इिपुट जसग्नल (उपाबंध ङ के परै ा 6 म ें जर्जिर्िवष्टािुसार) का अिुकरण करके परीिाओं के साथ जर्जध को िो़ििा आसाि या अजधक प्रभार्ी हो सकता ह।ै 3. सॉफ़्टर्ये र काय वके कायावत्मक परीिण द्वारा सत्यापि (र्ीएिटीएसडब्ल्यू),– (1) प्रयोग,– उिाहरण के सत्यापि के जलए मापिंडों की सुरिा, सॉफ़्टर्ेयर पहचाि का संकेत, सॉफ़्टर्ेयर समर्थवत िोष का पता लगािा, जसस्ट्टम का कॉजन्फगरेिि (जर्िेषकर सॉफ़्टर्ेयर र्ातार्रण का), आदि। (2) पूर्व ित,े – ऑपरेटटंग मैिअु ल, कायवप्रणाली पैटि,व माप-तौल संिभव और परीिण उपकरण अपेजित ह।ैं (3) जर्र्रण,– ऑपरेटटंग मैिअु ल, उपकरण िस्ट्तार्ेजीकरण या सॉफ़्टर्ेयर िस्ट्तार्ेजीकरण में र्र्णवत अपेजित सुजर्धाओं का अभ्यास में परीिण दकया िाता ह।ै यदि सॉफ़्टर्ेयर जियंजत्रत ह ैऔर सही ढगं स ेकाम कर रहा ह,ै तो उन्ह ें जबिा दकसी सॉफ़्टर्ेयर जर्श्लेषण के मान्य मािा िाएगा। (4) पठरणाम,– जर्चाराधीि सॉफ्टर्ेयर जियंजत्रत सुजर्धा सही ह ैया िहीं, इसकी िांच करिा। (5) पूरक प्रदक्रयाएाँ,– सॉफ़्टर्ेयर जियंजत्रत उपकरण की कुि जर्िेषताओं या कायों को र्णवि के अिुसार व्यार्हाठरक रूप से मान्य िहीं दकया िा सकता ह।ै यदि उपकरण म ेंइंटरफेस है, तो केर्ल यािजृ छिक रूप स ेकमांड आजमाकर अिजधकृत कमांड का पता लगािा आम तौर पर संभर् िहीं ह।ै इि आिेिों को उत्पन्न करि े के जलए भी एक प्रेषक की अपेिा होती ह।ै साधारण सत्यापि स्ट्तर जर्जध के जलए उपाबंध ङ. के पैरा 1 में जर्जिर्िवष्टािुसार, जर्जिमावता की घोषणा सजहत, इस अपेिा को कर्र कर सकता ह।ै जर्स्ट्ताठरत परीिा स्ट्तर के जलए, उपाबंध ङ. के परै ा 4 या उपाबंध ङ. के पैरा 5 िैसा सॉफ़्टर्ेयर जर्श्लेषण अपेजित ह।ै 4. मापर्ज्ञै ाजिक डाटा-फ्लो जर्श्लषे ण (डीएिए),– (1) प्रयोग,– डेटा डोमेि के माध्यम से माप मूल्यों के डेटा प्रर्ाह के जियंत्रण से संबंजधत सॉफ़्टर्ेयर जडजाइि के जर्श्लेषण के जलए, िो सॉफ़्टर्ेयर पृथक्करण की परीिा सजहत जर्जधक जियत्रं ण के अधीि ह।ै (2) पूर्व ित,ें – सॉफ़्टर्ेयर िस्ट्तार्ेजीकरण, सोसव कोड, संपािक, पाि खोि प्रोग्राम या जर्िेष उपकरण। प्रोग्राप्मंग भाषाओं का ज्ञाि।[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 71 (3) जर्र्रण,– इस जर्श्लेषण का उद्देश्य सॉफ्टर्ेयर के उि सभी भागों को ढूंढिा ह ैिो माप मूल्यों की गणिा म ेंिाजमल ह ैंया िो इस पर प्रभार् डाल सकत े ह।ैं (4) पठरणाम,– यह सत्याजपत दकया िा सकता ह ै दक उपाबंध ङ के पैरा 2 के जर्जिर्िवष्टािुसार सॉफ़्टर्ेयर पथृ क्करण िीक ह ै या िहीं। (5) पूरक प्रदक्रयाएाँ,– इस जर्जध का उपयोग तब दकया िाएगा िब सॉफ्टर्ेयर पृथक्करण को साकार दकया िािा हो और उच्च अिुरूपता या हरे िेर के जर्रुद् मिबूत सुरिा की अपेिा हो। 5. कोड जिरीिण और र्ॉल्क थ्र ू(सीआईडब्ल्यटू ी),– (1) प्रयोग,– यदि एंहस्ट्ै ड एक्साजमिेिि इंटेंजसट को अपेजित मािा िाता ह ै तो सॉफ़्टर्ेयर की दकसी भी सुजर्धा को इस पद्जत से मान्य दकया िा सकता ह।ै (2) कोड जिरीिण और र्ॉकथ्रू के जलए पूर् वितें,- स्रोत कोड, टेक्स्ट्ट एजडटर, टूल्स और प्रोग्राप्मंग भाषाओं का ज्ञाि अपेजित ह।ै (3) जर्र्रण,– परीिण प्रयोगिाला स्रोत कोड के प्रत्येक भाग का मूल्यांकि करती है, तथा यह जिधावठरत करती ह ै दक क्या अपेिाएं परू ी हुई ह,ैं तथा क्या प्रोग्राम के कायव और जर्िेषताए ंिस्ट्तार्ेजीकरण के अिरूु प ह।ैं परीिण प्रयोगिाला उि एल्गोठरिम या कायों पर भी ध्याि केंदद्रत कर सकती ह ै जिन्ह ें िठटल, त्रुठट-प्रर्ण, अपयावप्त रूप स ेप्रलेजखत आदि के रूप में पहचािा गया ह,ै तथा जर्श्लेषण और िााँच करके स्रोत कोड के संबंजधत भाग का जिरीिण कर सकती ह।ै (4) पठरणाम,– यह िांचिे के जलए दक क्या कायावन्र्यि सॉफ्टर्ेयर िस्ट्तार्ेज के साथ संगत ह ैऔर अपेिाओं के अिपु ालि म ें ह।ै (5) पूरक प्रदक्रयाएाँ,– यह उपाबंध ङ. के पैरा 1 और उि उपाबंध के पैरा 4 के अजतठरि एक उन्नत जर्जध ह।ै साधारणतया इस े केर्ल स्ट्पॉट िांच में ही प्रयुि दकया िाता ह।ै 6. सॉफ्टर्अे र मॉड्यलू पठरिण (एसएमटी),– (1) प्रयोग,– केर्ल तभी िब धोखाध़िी के जर्रुद् उच्च स्ट्तरीय सरु िा और संरिण की अपेिा हो। यह जर्जध तब प्रयिु की िाती ह ैिब दकसी प्रयोग की रूठटि की िांच जर्िेष रूप स े जलजखत िािकारी के आधार पर िहीं की िा सकती ह ैऔर यह गजतिील माप एल्गोठरिम को मान्य करि े में उजचत और आर्थवक रूप से लाभप्रि ह।ै (2) पूर्व ित,े – सोसव कोड, जर्कास उपकरण (कम से कम एक कंपाइलर), परीिण के अधीि सॉफ्टर्ेयर मॉड्यलू का कायविील र्ातार्रण, इिपुट डटे ा सेट और संबंजधत सही संिभ वआउटपुट डेटा सेट या स्ट्र्चालि के जलए उपकरण, चिा प्रौद्योजगकी में कौिल, प्रोग्राप्मंग भाषाओं का ज्ञाि और परीिण के अधीि मॉड्यूल के प्रोग्रामर के साथ सहयोग अपेजित ह।ै (3) जर्र्रण,–72 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] परीिण के अधीि सॉफ्टर्ेयर मॉड्यूल एक परीिण र्ातार्रण में एकीकृत होता है, अथावत् एक जर्जिष्ट टेस्ट्ट प्रोग्राम मॉड्यलू िो परीिण के अधीि मॉड्यूल को कॉल करता ह ैऔर इस ेसभी अपेजित इिपटु डेटा प्रिाि करता ह।ै परीिण प्रो अपेजित संिभव मािों के साथ परीिण के अधीि मॉड्यलू से आउटपुट डेटा की तुलिा करता ह।ै (4) पठरणाम,– यह िांचिे के जलए दक मापि एल्गोठरथ्म या अन्य परीिजणत फंक्िि सही ह ैंया िहीं। (5) पूरक प्रदक्रयाएाँ,– यह एक उन्नत जर्जध ह,ै िो उपाबंध ङ. के परै ा 2 या उि उपाबंध के पैरा 5 के अजतठरि ह।ै “ [िा. स.ं डब्ल्यूएम-9(39)/2015] अिुपम जमश्रा, संयिु सजचर् ठटप्पण:- मूल जियम भारत के रािपत्र, असाधारण, भाग II, खंड 3, उपखंड (i) म ें अजधसूचिा संख्या सा.का.जि. 71(अ), तारीख 7 िरर्री, 2011 द्वारा प्रकाजित दकए गए थ े और अंजतम बार अजधसूचिा संख्या सा.का.जि. 34(अ), तारीख 14 ििर्री, 2025 द्वारा संिोजधत दकए गए थे। MINISTRY OF CONSUMER AFFAIRS, FOOD AND PUBLIC DISTRIBUTION (DEPARTMENT OF CONSUMER AFFAIRS) NOTIFICATION New Delhi, the 21st April, 2025 G.S.R. 242(E).— In exercise of the powers conferred by sub-section (1) read with clauses (c), (f), (h), (i) and (s) of sub-section (2) of section 52 of the Legal Metrology Act 2009, (1 of 2010), the Central Government hereby makes the following rules, further to amend the Legal Metrology (General) Rules, 2011, namely:- 1. Short title and commencement.- (1) These rules may be called the Legal Metrology (General) Second Amendment Rules, 2025. (2) They shall come into force on the 1st day of September, 2025. 2. In the Legal Metrology (General) Rules, 2011 (hereinafter referred to as the said rules), after rule 27, the following rule shall be inserted, namely:- “27A. Special provision for re-verification.-The re- verification of the following meters shall be carried out on the completion of the period specified in the following Table below, namely:- (a) for Volumetric Meters,- Table 1. Serial No. Type Sub-type Initial re-verification period Subsequent re- verification period (1) (2) (3) (4) (5) 1. Diaphragm Meter 7 years 5 years 2. Rotary Pressure body 20 years 17 years 3. Turbine All types 6 years 4 years 4. plate, fitting, tubes, and flow Orifice conditioner 6 years 4 years 5. Ultrasonic gas Ultrasonic meter 6 years 4 years 6. Fluidic- oscillation All types 6 years 4 years 7. Vortex All types 6 years 4 years 8. Cone- shaped All types 6 years 4 years[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 73 differential pressure (b) for Mass-flow Meters,- Table 2. Serial No. Type Sub-type Initial re-verification period Subsequent re- verification period (1) (2) (3) (4) (5) 9. NGV Dispenser Coriolis System 1 year 1 year All Other types 6 years 4 years 10. Thermal All types 6 years 4 years (c) for Base Pressure and temperature conversion devices or Recording devices,- Table 3. Serial No. Type Sub-type Initial re-verification period Subsequent re- verification period (1) (2) (3) (4) (5) 11. Chart Recorder All types same as the host meter same as the host meter 12. Mechanical- type Rotary meter 7 years 5 years Volume Conversion modules Device All other types 13. Electronic- type All types 7 years 5 years Volume Conversion Device 14. Flow Computer All types 6 years 4 years 15. Transducer or All types 7 years 5 years Transmitter (d) for other Meters, devices, and installations,- Meter devices and installation not covered in serial numbers 1 to 15 above. Table 4. Serial No. Type Sub-type Initial re-verification period Subsequent re- verification period (1) (2) (3) (4) (5) 16. Gas Analyser or All types 1 year 1 year Chromatograph 17. Energy Density All types 1 year 1 year 18. Relative Density All types 1 year 1 year 19. Flow Conditioner Perforated plate same as the host meter same as the host meter Tube bundle same as the host meter same as the host meter (straightening vanes) 20. Correction Device All types (2) same as the host meter same as the host meter 21. Ticket printer All types same as the host meter same as the host meter 22. Telemetering Device All types same as the host meter same as the host meter or System 23. Metering Installations Pressure factor same as the host meter same as the host meter metering (PFM) All other types same as the host meter same as the host meter Note (1): Re-verification period shall be as stated above and the devices shall be inspected at their operational location at the time of re-verification of meter. Note (2): The “linearisation” function may either be incorporated into the circuit design of an electronic volumetric meter or a flow computer, or in a separate correcting device.74 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] Note (3): The verification or re-verification of other devices (such as Electronic- type Volume Conversion Devices, Flow computers and Transducer or Transmitter) which may affect the measurement shall be done.”. 3. In the Eighth Schedule to the said rules, after PART X the following PART shall be inserted, namely.- “PART XI GAS METERS Part 1 Metrological and technical requirements 1. Scope.- (1) This part applies to gas meters based on any measurement technology or principle that is used to measure the quantity of gas that has passed through the meter at operating conditions. The quantity of gas can be expressed in units of volume or mass. (2) This part applies to gas meters intended to measure quantities of gaseous fuels or other gases. It does not cover meters used for gases in the liquefied state, multi-phase steam and compressed natural gas used in compressed natural gas dispensers. (3) This part applies to built-in correction devices, devices for internal temperature compensation and includes any other electronic device that may be attached to the gas meter. 2. Terminology.- (1) Gas meter and its constituents,- (i) gas meter,- The instrument intended to measure, memorise and display the quantity of gas passing the flow sensor; (ii) measurand,- The quantity intended to be measured; (iii) sensor,- An element of a measuring system that is directly affected by a phenomenon, body, or substance carrying a quantity to be measured; (iv) measuring transducer,- The device used in measurement that provides an output quantity having a specified relation to the input quantity; (v) calculator,- The part of the gas meter which receives the output signals from the measuring transducer and associated measuring instruments, transforms them and stores the results in memory until they are used. In addition, the calculator may be capable of communicating both ways with ancillary devices; (vi) indicating or displaying device,- The part of the gas meter which displays the measurement results, either continuously or on demand; Note: A printing device which provides an indication at the end of the measurement is not an indicating device. (vii) correction device,- The device intended for correction of known errors in the function, for instance in the flow rate, Reynolds number (curve linearisation), density, pressure or temperature or a combination thereof; (viii) ancillary device,-[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 75 The device intended to perform a particular function, directly involved in elaborating, transmitting or displaying measurement results. The main ancillary devices are,- (a) repeating indicating device; (b) printing device; (c) memory device; and (d) communication device. Note 1: An ancillary device is not necessarily subject to metrological control. Note 2: An ancillary device may be integrated in the gas meter. (ix) associated measuring instrument,- The instrument connected to the calculator or the correction device for measuring certain gas properties for the purpose of making a correction; (x) equipment under test (equipment under test),- The part of the gas meter or associated devices or both which is exposed to one of the tests; (xi) family of gas meters,- The group of gas meters of different sizes or different flow rates or a combination thereof, in which all the meters shall have the following characteristics; namely:- (a) the same manufacturer; (b) geometric similarity of the measuring part; (c) the same metering principle; (d) roughly the same ratios Qmax/Qmin and Qmax/Qt; (e) the same accuracy class; (f) the same electronic device [as specified in clause (ii) of sub-paragraph (5) of paragraph 2] for each meter size and using the same metrological software routines (if applicable) for those components that are critical to the performance of the meter; (g) a similar standard of design and component assembly; and (h) the same materials for those components that are critical to the performance of the meter. (2) Metrological characteristics, - (i) quantity of gas,- The total quantity of gas obtained by integrating the flow passed through the gas meter over time, which is expressed as volume ‘V’ or mass ‘m’, disregarding the time taken. The quantity of gas is the measurand concerned [as defined in clause (ii) of sub-paragraph (1) of paragraph 2]; (ii) indicated value (of a quantity),- The value Y of a quantity as indicated by the meter; i (iii) cyclic volume of a gas meter (positive displacement gas meters only) ,- The volume of gas corresponding to one full revolution of the moving parts inside the meter (working cycle); (iv) error,- The measured quantity value minus a reference quantity value; (v) weighted mean error (WME),- The weighted mean error (WME) within this rule is defined as: WME = with k = for Q ≤ 0.7 Q i i max76 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] k = 1.4- for 0.7 Q ≤ Q ≤ Q i max i max where: k = weighting factor at the flow rate Q; i i E = the error at the flow rate Q. i i (vi) intrinsic error,- The error determined under reference conditions; (vii) fault,- The difference between the error of indication and the intrinsic error of a measuring instrument. Note 1: In practice this is the difference between the error of the meter observed during or after a test and the error of the meter prior to this test, performed under reference conditions. Note 2: “measuring instrument” is to be interpreted as a “gas meter”. (viii) maximum permissible error (MPE) ,- The extreme value of measurement error, with respect to a known reference quantity value, permitted by specifications or regulations for a given measurement, measuring instrument, or measuring system; (ix) accuracy class,- The class of measuring instruments or measuring systems which meet the stated metrological requirements that are intended to keep measurement errors or instrumental uncertainties within specified limits under specified operating conditions; (x) durability,- It refers to the ability of a measuring instrument to maintain its performance characteristics over a period of use; (xi) measurement precision,- The closeness of agreement between indications or measured quantity values obtained by replicate measurements on the same or similar objects under specified conditions; (xii) repeatability,- It refers to the measurement precision under a set of repeatability conditions of measurement; (xiii) repeatability of error,- It refers to the repeatability under reference conditions and not changing the flow rate between the measurements; (xiv) reproducibility,- It refers to the measurement precision under reproducibility condition of measurement; (xv) reproducibility of error,- It refers to the reproducibility under reference conditions and changing the flow rate between the measurements; (xvi) operating conditions,- The conditions of the gas (temperature, pressure and gas composition) at which the quantity of gas is measured; (xvii) rated operating conditions,- The conditions of use giving the range of values of the measurand and the influence quantities for which the errors of the gas meter are required to be within the limits of the maximum permissible error; (xviii) reference conditions,-[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 77 The set of reference values, or reference ranges of influence quantities prescribed for testing the performance of a gas meter or for the intercomparison of the results of measurements; (xix) base conditions,- The conditions to which the measured volume of gas is converted (examples: base temperature and base pressure). Note: Operating and base conditions relate to the volume of gas to be measured or indicated only and should not be confused with “rated operating conditions” and “reference conditions” which refer to influence quantities. (xx) test element (of an indicating device),- The device to enable precise reading of the measured gas quantity; (xxi) resolution (of a displaying device),- The smallest difference between displayed indications that can be meaningfully distinguished. Note: For a digital device, if significant the change in the indication when the least significant digit changes by one step. For an analogue device, this is half the difference between subsequent scale marks. (xxii) instrumental drift,- The continuous or incremental change over time in indication, due to changes in the metrological properties of a measuring instrument. (3) Operating conditions,- The conditions of the gas (temperature, pressure and gas composition) at which the quantity of gas is measured; (i) flow rate (Q),- The quotient of the actual quantity of gas passing through the gas meter and the time taken for this quantity to pass through the gas meter; (ii) maximum flow rate (Q ,- max) The highest flow rate at which a gas meter is required to operate within the limits of its maximum permissible error whilst being operated within its rated operating conditions; (iii) minimum flow rate (Q ,- min) The lowest flow rate at which a gas meter is required to operate within the limits of its maximum permissible error whilst being operated within its rated operating conditions; (iv) transitional flow rate (Q ,- t) The rate which occurs between the maximum flow rate Q and the minimum flow rate Q that max min divides the flow rate range into two zones, the “upper zone” and the “lower zone”, each characterised by its own maximum permissible error; (v) working temperature (t ),- w The temperature of the gas to be measured at the gas meter; (vi) minimum working temperature (t )and maximum working temperature (t ),- min max The minimum and maximum gas temperature that a gas meter can withstand, within its rated operating conditions, without unacceptable deterioration of its metrological performance; (vii) specified temperature (t ),- sp The median temperature for gas meters with built-in conversion devices used as a reference for the determination of the applicable operating temperature range. Note: The difference between t and the gas temperature has an influence on the value of the maximum sp permissible error. (viii) working pressure (p ),- w The pressure of the gas to be measured at the gas meter; (ix) minimum working pressure (p )and maximum working pressure (p ),- min max78 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] The minimum and maximum internal pressure that a gas meter can withstand, within its rated operating conditions, without deterioration of its metrological performance; (x) static pressure loss or pressure differential (Δp),- The difference between the pressures at the inlet and outlet of the gas meter while the gas is flowing; (xi ) working density (ρ ),- w The density of the gas flowing through the gas meter, corresponding to ρ and t . w w (4) Test conditions,- (i) influence quantity,- The quantity that in a direct measurement does not affect the quantity that is actually measured but affects the relation between the indication and the measurement result; (ii) disturbance,- The influence quantity having a value within the limits specified in this part but outside the specified rated operating conditions of the gas meter. Note: An influence quantity is a disturbance if for that influence quantity the rated operating conditions are not specified. (iii) overload conditions,- The conditions outside the rated operating conditions (including flow rate, temperature, pressure, humidity and electromagnetic interference) that a gas meter is required to withstand without deterioration of its performance; (iv) test,- The series of operations intended to verify the compliance of the equipment under test (equipment under test) with certain requirements; (v) test procedure,- The detailed description of the test operations; (vi) test program,- The description of a series of tests for a certain type of equipment; (vii) performance test,- The test intended to verify whether the equipment under test (equipment under test) is capable of accomplishing its intended functions. (5) Electronic equipment,- (i) electronic gas meter,- The gas meter equipped with electronic devices. Note: For the purposes of this part ancillary equipment, as far as it is subject to metrological control, is considered part of the gas meter, unless the ancillary equipment is approved and verified separately. (ii) electronic device,- The device employing electronic sub-assemblies and performing a specific function. Electronic devices are usually manufactured as separate units and are capable of being tested independently; (iii) electronic component,- The smallest physical entity in an electronic device used to affect electrons and/or their associated fields in their movement through a medium or vacuum. 3. Units of measurement.- (1) Measurement units,- All quantities shall be expressed in SI units.[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 79 4. Metrological requirements.- (1) Rated operating conditions,- Table A. Rated operating conditions for a gas meter shall be as follows: (1) (2) (3) (a) Ambient temperature (Temperature Low –40°C, –25°C, –10°C, 00C and +5°C (1) range chosen shall at least cover 50 High +30°C,+40°C,+55°C, 650C and +70°C (1) K) (b) Ambient relative humidity As specified by the manufacturer; at least up to 93% (c) Atmospheric pressure As specified by the manufacturer; at least covering 86 kPa – 106 kPa (d) Vibration less than 10 Hz – 150 Hz, 1.6 ms-2, 0.05 m2s-3, -3dB/octave (e) DC mains voltage (3) As specified by the manufacturer (f) AC mains voltage (3) U – 15% to U + 10% nom nom (g) AC mains frequency (3) f – 2 % to f + 2% nom nom (h) Flow rate range Q to Q inclusive min max (i) Type of gases The family of natural gases, industrial gases, or supercritical gases; to be specified by the manufacturer (2), (j) Working pressure range: p to p inclusive min max (1) Different values of temperature are allowed depending on the different climatic conditions of the country. (2) Supercritical refers to the situation where there is no distinction between the gaseous and liquefied state of the fluid (3) If applicable (2) Values of Q , Q and Q ,- max t min The flow rate characteristics of a gas meter shall be defined by the values of Q Q and Q . Their max, t min ratios and relations shall be within the ranges as specified in Table 1: Table 1. Flow rate characteristics Q / Q Q / Q max min max t (1) (2) ≥ 50 ≥ 10 ≥ 5 and <50 ≥ 5 (3) Accuracy classes and maximum permissible errors (MPE),- (i) General,- A gas meter shall be designed and manufactured such that its errors do not exceed the applicable MPE under rated operating conditions; (ii) Accuracy classes,- Gas meters may be divided in three accuracy classes 0.5, 1 and 1.5. A gas meter shall be classified according to its accuracy in one of these classes. The value of the MPE is dependent on the applicable accuracy class as specified in Table 2 below; (iii) Correction for known errors,- A gas meter may be equipped with a correction device, intended to reduce the errors as close as possible to the zero value. Such a correction device shall not be used for the correction of a pre-estimated drift; (iv) Maximum permissible errors (MPE),- Table 2. Maximum permissible errors of gas meters Flow rate Q During model approval and During re-verification and in-service initial verification Accuracy class Accuracy class 0.5 1 1.5 0.5 1 1.580 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (1) (2) (3) (4) (5) (6) (7) Q ≤ Q <Q ± 1 % ± 2 % ± 3 % ± 2 % ± 4 % ± 6 % min t Q ≤ Q ≤ Q ± 0.5 % ± 1 % ± 1.5 % ± 1 % ± 2 % ± 3 % t max (v) Gas meter with a built-in conversion device,- For a gas meter with a built-in conversion device and displaying the volume at base conditions only, the maximum permissible errors as specified in Table 2 are increased by 0.5 % in the temperature range of (t – 15) °C to sp (t + 15) °C. Outside this temperature range an additional increase of 0.5 % per additional interval of 10 °C is sp permitted to this extended MPE. The temperature t is specified by the manufacturer. sp Note 1: The conversion may be based on temperature or pressure measurements or both. Note 2: Gas meters indicating both actual volume and volume at base conditions are considered gas metering systems. (4) Weighted mean error (WME),- The weighted mean error (WME) shall be within the values as specified in Table 3. Table 3. Maximum permissible weighted mean error Flow rate Q During model approval and During re-verification initial verification and in-service Accuracy class Accuracy class 0.5 1 1.5 0.5 1 1.5 (1) (2) (3) (4) (5) (6) (7) WME ± 0.2 % ± 0.4 % ± 0.6 % - - - (5) Repair and damage of seals,- After repair of components of the gas meter which affect the metrological behavior or after damage to the seals, the maximum permissible error shall comply with the errors on initial verification as specified in Table 2, as well as the maximum permissible weighted mean error as specified in Table 3. (6) Reproducibility,- For flow rates equal to or greater than Q the reproducibility of error at the specific flow rate shall be less t, than or equal to one third of the maximum permissible error. (7) Repeatability,- The repeatability of error of three consecutive measurements at the specific flow rate shall be less than or equal to one third of the maximum permissible error. (8) Working pressure,- The requirements as mentioned in sub-paragraph (3) of paragraph 4 shall be fulfilled over the whole working pressure range. (9) Temperature,- The requirements as mentioned in sub-paragraph (3) of paragraph 4 shall be fulfilled over the whole temperature range, where the ambient temperature equals the gas temperature within 5°C. For gas meters indicating the volume at base conditions only, the double maximum permissible error limits for flow rates equal to or above Q apply when the ambient temperature differs by 20 °C or more from the gas t temperature. (10) Durability,-[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 81 A gas meter shall meet the following requirements after being subjected to a flow with rate between 0.8 Q max and Q comprising a quantity that is equivalent to a flow at Q during a period of 2000 hours, namely:- max max (i) the maximum permissible errors as specified in Table 2 for re-verification and in use; and (ii) for flow rates from Q up to Q a fault of less than or equal to,- t max - 1.0 times the maximum permissible error applicable during model approval for class 1.5 or - 0.5 times the maximum permissible error applicable during model approval for other classes. (11) Overload flow,- A gas meter shall comply with the following requirements, after being exposed to an overload of 1.2 Q for a max period of 1 hour, - (i) the maximum permissible errors as mentioned in sub-paragraph (3) of paragraph 4; and (ii) a fault of less than or equal to one-third of the maximum permissible error. (12) Vibrations and shocks,- A gas meter shall withstand vibrations and shocks with the following specifications: (i) vibrations,- total frequency range: 10 Hz – 150 Hz total RMS level: 7 m.s-2 ASD level 10 Hz – 20 Hz: 1 m2s-3 ASD level 20 Hz – 150 Hz: –3 dB/octave (ii) shocks,- height of fall: 50 mm The fault after the application of vibrations and shocks shall be less than or equal to 0.5 times the maximum permissible error. (13) Metrological requirements specific to certain types of gas meters,- (i) Orientation,- If the manufacturer of the meter specifies that the meter will only operate correctly while installed in certain orientations and if the meter is marked as such, the metrological requirements specified in sub-paragraph (3) and (4) of paragraph 4 shall be fulfilled for these orientations only; In the absence of such marks the meter shall fulfill these requirements for all orientations; (ii) Flow direction,- If the meter is marked as being able to measure the flow in both directions, the metrological requirements specified in sub-paragraph (3) and (4) of paragraph 4 shall be fulfilled for each direction separately; (iii) Flow disturbance,- For types of gas meters of which the accuracy is affected by flow disturbances, the shift of the error due to these disturbances shall not exceed one third of the maximum permissible error. In case such a gas meter is specified to be installed in specific piping arrangements producing only mild flow disturbances, the meter shall be marked as such and may only be installed in those specific piping configurations for which its accuracy has proven to stay within this requirement; (iv) Drive shaft (torque),- For types of gas meters with one or more drive shafts, any fault which results from the application of the maximum torque, as specified by the manufacturer, shall not be more than one third of the maximum permissible error; (v) Different gases,-82 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] The types of gas meters which are intended to be used for different gases shall comply with the metrological requirements as mentioned in sub-paragraph (3) of paragraph 4 over the whole range of gases for which they are specified by the manufacturer; (vi) Interchangeable components,- For types of gas meters of which some components are intended to be interchangeable for operational purposes (e.g. ultrasonic transducers or meter cartridges), the fault due to the interchange of such a component shall not be more than one third of the maximum permissible error applicable during type evaluation, while the error shall in no case exceed the maximum permissible error for that range; (vii) Electronics,- If a gas meter includes electronic components, the requirements as specified in Table 4 and Table 5 shall apply; (viii) Influences from ancillary devices,- Gas meters provided with ancillary devices shall be designed such that all functions of the ancillary devices (e.g. provisions for communication purposes) do not affect the metrological behavior. Table 4. Requirements for gas meters containing electronic components Serial Influence factor Range Error limit No. (1) (2) (3) (4) (a) Dry heat Upper temperature specified MPE (b) Cold heat Upper temperature specified MPE (c) Damp heat, steady state upper temperature specified, MPE (non-condensing) 93 % relative humidity (d) DC mains voltage as specified by the manufacturer MPE variation (1) (e) AC mains voltage 85 % & 110 % of the rated voltage MPE variation (1) (f) Low voltage of internal as specified by the manufacturer MPE battery (1) (1) If applicable Table 5. Immunity requirements for gas meters containing electronic components: Serial Disturbance Required immunity Fault limit / test No. condition (3) (1) (2) (3) (4) (a) Damp heat cyclic upper temperature, specified ½ MPE / NSFa (condensing) 93 % relative humidity (b) Vibrations (random) total frequency range: 10 Hz – 150 Hz ½ MPE / NSFa total RMS level: 7 m.s-2 ASD level 10 Hz–20 Hz: 1 m2.s-3 ASD level 20 Hz–150 Hz: –3dB/octave (c) Mechanical shock 50 mm ½ MPE / NSFa (d) Radiated radio frequency, 10 V/m, up to 3 GHz MPE / NSFd electromagnetic fields (e) Conducted (common 10 V (e.m.f.), up to 80MHz MPE / NSFd mode) currents generated by radio frequency electro magnetic fields (f) Electrostatic discharges 6 kV contact discharge ½ MPE / NSFa+d 8 kV air discharge (g) Bursts (transients) on Amplitude 1 kV ½ MPE / NSFd signal, data and Repetition rate 5 kHz[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 83 controllines (h) Surges on signal, data and unsymmetrical lines: ½ MPE / NSFd control lines line to line 0.5 kV line to ground 1.0 kV symmetrical lines: line to line NA line to ground 1.0 kV shielded input/ output and communication lines: line to line NA line to ground 0.5 kV (i) AC mains voltage dips ½ cycle 0 % ½ MPE / NSFd and short interruptions (1) 1 cycle 0 % 10/12(2) cycles 40 % 25/30(2) cycles 70 % 250/300 (2) cycles 80 % (j) DC mains voltage dips 40 % and 70 % of the rated voltage during ½ MPE / NSFd and short interruptions (1) 0.1 s and 0% of rated voltage during 0.01 s (k) Bursts (transients) on AC Amplitude 2 kV ½ MPE / NSFd and DC mains Repetition rate 5 kHz (l) Surges on AC and DC line to line 1.0 kV ½ MPE / NSFa+d Mains line to ground 2.0 kV (m) Ripple on DC mains 2 % of nominal DC voltage ½ MPE / NSFd power (1) (1) If applicable (2) For 50 Hz/ 60 Hz respectively (3)NSFa: No significant fault shall occur after the disturbance. NSFd: No significant fault shall occur during the disturbance. Tests specified in serial number (e) (g) and (h) are not applicable for non-mains connected gas meters. Tests mentioned in serial number in (k) and (l) are not applicable, if meter is not connected by AC or DC mains. 5. Technical requirements.- (1) Construction,- (i) Materials,- A gas meter shall be made of such materials and be so constructed to withstand the physical, chemical and thermal conditions to which it is likely to be subjected and to correctly fulfill its intended purposes throughout its life; (ii) Soundness of cases,- The case of a gas meter shall be gas-tight as specified according to national or international standards and requirements concerning safety and at least up to 1.5 times of the maximum working pressure of the gas meter. If a meter is to be installed in the open air it shall be impermeable to run-off water; (iii) Condensation and climate provisions,- The manufacturer may incorporate devices for the reduction of condensation, where condensation may adversely affect the performance of the device; (iv) Protection against external interference,- A gas meter shall be constructed and installed in such a manner that mechanical interference capable of affecting its accuracy is either prevented, or results in permanently visible damage to the gas meter or to the verification marks or protection marks; (v) Indicating device,- The indicating device can be connected to the meter body physically or remotely. In the latter case the data to be displayed shall be stored in the gas meter; Note: There shall be provisions to access the data for customers and consumers. (vi) Safety device,-84 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] The gas meter shall be equipped with a safety device that shuts off the gas flow in the event of calamities, such as an earthquake or a fire. A safety device shall be connected to the gas meter, provided that it does not influence the metrological integrity of the meter. A mechanical gas meter equipped with an earthquake sensor plus an electrical powered valve is not considered to be an electronic gas meter; (vii) Connections between electronic parts,- Connections between electronic parts shall be reliable and durable; (viii) Components,- Components of the meter may only be exchanged without re-verification if the model approval establishes that the metrological properties and especially the accuracy of the meter are not influenced by the exchange of the components concerned [see clause (vi) of sub-paragraph (13) of paragraph 4]. Such components shall be identified by the manufacturer by their own unique part numbers or identifiers. Note: These components shall be marked with the model of the meter to which they may be attached and may require exchange. (ix) Zero flow,- The gas meter totalisation shall not change when the flow rate is zero and the installation conditions are free from flow pulsations. Note: This requirement refers to stationary operating conditions. This condition does not refer to the response of the gas meter to changed flow rates. (2) Flow direction,- (i) Direction of the gas flow,- On a gas meter where the indicating device registers positively for only one direction of the gas flow, this direction shall be indicated by a method which is clearly understood, e.g. an arrow. This indication is not required if the direction of the gas flow is determined by the construction; (ii) Plus and minus sign,- The manufacturer shall specify whether or not the gas meter is designed to measure bi- directional flow. In the case of bi-directional flow a double-headed arrow with a plus and minus sign shall be used to indicate which flow direction is regarded as positive and negative respectively; (iii) Recording of bi-directional flow,- If a meter is designed for bi-directional use, the quantity of gas passed during reverse flow shall either be subtracted from the indicated quantity or be recorded separately. The maximum permissible error shall be met for both forward and reverse flow; (iv) Reverse flow,- If a meter is not designed to measure reverse flow, the meter shall either prevent reverse flow, or it shall withstand incidental or accidental reverse flow without deterioration or change in its metrological properties concerning forward flow measurements; (v) Indicating device,- A gas meter may be provided with a device to prevent the indicating device from functioning whenever gas is flowing in an unauthorised direction. (3) Indicating device,- (i) General provisions,- The indicating device associated with the gas meter shall indicate the quantity of gas measured in volume or mass in the corresponding units. The reading shall be clear and unambiguous. The indicating device may be,- (a) a mechanical indicating device as specified in clause (iv) of sub-paragraph (3) of paragraph 5; (b) an electromechanical or electronic indicating device as specified in clause (v) of sub-paragraph (3) of paragraph 5; (c) a combination of (a) and (b).[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 85 Indicating devices shall be non-resettable and non-volatile i.e. they shall be able to show the last stored indication after the device has recovered from an intervening power failure. Where the indicating device shows decimal submultiples of the quantity measured, this fraction shall be separated from the integer value by a clear decimal sign. It may be possible to use one display for other indications as well, as long as it is clear which quantity is being displayed. (ii) Indicating range,- The indicating device shall be able to record and display the indicated quantity of gas corresponding to at least 1000 hours of operation at the maximum flow rate Qmax, without returning to the original reading. (iii) Resolution,- The quantity corresponding to the least significant digit shall not exceed the quantity of gas passed during one hour at Q . min If the least significant digit (e.g. last drum) shows a decimal multiple of the quantity measured, the face plate or electronic display shall bear: (a) either one or two, or three, etc. fixed zero after the last drum or digit; or (b) the marking: "× 10" or "× 100", or "× 1000", etc., so that the reading is always in the units specified in sub-paragraph (1) of paragraph 3. (iv) Mechanical indicating device,- The minimum height of the numerals shall be 4.0 mm and their minimum width shall be 2.4 mm. The last element (i.e. the decade with the least significant scale interval) of a mechanical indicating device may deviate in manner of display from the other decades. In the case of drum indicating devices, the advance by one unit of a figure of any order shall take place completely while the figure of an order immediately below passes through the last tenth of its course; (v) Electromechanical or electronic indicating device,- The continuous display of the quantity of gas during the period of measurement is not mandatory. The electronic indicating device shall be provided with a display test; (vi) Remote indicating device,- If an indicating device is used remotely, the associated gas meter shall be clearly identified. The integrity of the communication between the instrument and the indicating device shall be checked. Note: The serial number of the associated gas meter can be used for a clear identification. (4) Test element,- (i) General,- A gas meter shall be designed and constructed incorporating the following, namely:- (a) an integral test element; or (b) a pulse generator; or (c) arrangements permitting the connection of a portable test unit. (ii) Integral test element,- The integral test element may consist of the last element of the mechanical indicating device in one of the following forms, namely:- (a) a continuously moving drum bearing a scale, where each subdivision on the drum is regarded as an increment of the test element; (b) a pointer moving over a fixed dial with a scale, or a disk with a scale moving past a fixed reference mark, where each sub-division on the dial or disk is regarded as an increment of the test element. On the numbered scale of a test element the value of one complete revolution of the pointer shall be indicated in86 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] the form: "1 revolution = m3 or kg or ……<unit>". The beginning of the scale shall be indicated by the figure zero. The scale spacing shall not be less than 1 mm and shall be constant throughout the whole scale. The scale interval shall be in the form 1 × 10n, 2 × 10n, or 5 × 10n m3 or kg or ……<unit> (n being a positive or negative whole number or zero). The scale marks shall be fine and uniformly drawn. With an electronic indicating device the last digit is used as the integral test element. Through either physical or electronic means, a specific test mode may be entered in which the number of digits may be increased or some alternative method may be applied for gaining resolution. If applicable to the gas meter, the test element shall allow the experimental determination of the cyclic volume. The difference between the measured value of the cyclic volume and its nominal value shall not exceed 5 % of the latter at reference conditions; (iii) Pulse generator,- A pulse generator may be used as a test element if the value of one pulse, expressed in units of volume or mass, is marked on the gas meter. The gas meter shall be constructed in such a way that the pulse value can be checked experimentally. The difference between the measured value of the pulse value and its value indicated on the gas meter shall not exceed 0.05 % of the latter; (iv) Attachable test device,- An indicating device may include provisions for testing by inclusion of complementary elements (e.g. star wheels or discs), which provide signals for an attachable test device. The attachable test device may be used as a test element if the value of one pulse, expressed in units of volume or mass, is marked on the gas meter; (v) Increment of test element or pulse,- The increment of the test element or pulse shall occur at least every 60 seconds at Q . min (5) Ancillary devices,- (i) General,- The gas meter may include ancillary devices, which may be permanently incorporated or added temporarily. Examples of applications are,- (a) flow detection before this is clearly visible on the indicating device; (b) means for testing, verification and remote reading; (c) prepayment; Ancillary devices shall not affect the correct operation of the instrument. If an ancillary device is not subject to legal metrology control this shall be clearly indicated; (ii) Protection of drive shafts,- When not connected to an attachable ancillary device, the exposed ends of the drive shaft shall be suitably protected; (iii) Torque overload,- The connection between the measuring transducer and the intermediate gearing shall not break or alter if a torque of three times the permissible torque as indicated in sub-clause (b) of clause (iii) of sub-paragraph (1) of paragraph 6 and sub-clause (c) of clause (iii) of sub-paragraph (1) of paragraph 6 is applied. (6) Power sources,- (i) Types of power sources,- Gas meters may be powered by the following, namely:-[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 87 (a) mains power sources; (b) non-replaceable power sources; or (c) replaceable power sources. These three types of power source may be used alone or in combination. Note: For the purpose of this part, rechargeable power sources are considered replaceable. (ii) Mains power,- An electronic gas meter shall be designed to ensure that in the event of a mains power failure (AC or DC), the meter indication of the quantity of gas just before failure is not lost, and remains accessible for reading after failure without any difficulty. Any other properties or parameters of the meter shall not be affected by an interruption of the electrical supply. Note: Compliance with this requirement will ensure that the gas meter will continue to register the quantity of gas that passed through the gas meter during a power failure (may be through a mechanical assembly). The connection to the mains power source shall be secured from tampering. (iii) Non-replaceable power source,- The manufacturer shall ensure that the indicated lifetime of the power source guarantees that the meter functions correctly for at least as long as the operational lifetime of the meter which shall be marked on the meter or, alternatively, the remaining battery capacity in units of time can be presented on the electronic indicating device. (iv) Replaceable power source,- If the instrument is powered by a replaceable power source, the manufacturer shall give detailed specifications for the replacement thereof. The date by which the power source is to be replaced shall be indicated on the meter. Alternatively, the estimated remaining life of the power source shall be displayed or a warning shall be given when the estimated remaining life of the power source is 10% or below. The properties and parameters of the meter shall not be affected during replacement of the power source. It shall be possible to replace the power source without breaking the metrological seal. The compartment of the power source shall be capable of being secured from tampering. (7) Checks, limits and alarms for electronic gas meters,- (i) Checks,- An electronic gas meter is required to check,- (a) the presence and correct functioning of transducers and critical devices; (b) the integrity of stored, transmitted and indicated data; and (c) the pulse transmission (if applicable). Note: Pulse transmission checks focus on missing pulses, or additional pulses due to interference. Examples are double pulse systems, three-pulse systems or pulse timing systems. (ii) Limits,- The gas meter may also have the capability to detect and act upon: (a) overload flow conditions; (b) measurement results that are outside the maximum and minimum values of the transducers; (c) measured quantities that are outside certain pre-programmed limits; and (d) reverse flow.88 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] If the gas meter is equipped with limit detection, the correct functioning shall be tested during the type evaluation. (iii) Alarms,- If malfunctions are registered while checking the items as indicated in clause (i) of sub-paragraph (7) of paragraph 5 or if the conditions as indicated in clause (ii) of sub-paragraph (7) of paragraph 5 are detected, the following actions shall be performed, namely:- (a) a visible or audible alarm or both, which remains present until the alarm is acknowledged and the cause of the alarm is suppressed; (b) continuation of the registration in specific alarm registers (if applicable) during the alarm, in which case default values may be used for the pressure, temperature, compressibility, or density; and (c) registration in a log (if applicable). (8) Software,- The requirements concerning the software applied in the gas meters are made in the mandatory Annexure I. 6. Inscriptions.- (1) Markings and inscriptions,- All markings shall be easily legible and indelible under rated conditions of use. Any marking other than those prescribed in the model approval document shall not lead to confusion. The following information shall be marked on the casing or on an identification plate. Alternatively, the markings presented with an asterisk (*) shall be made visible via the electronic indicating device in a clear and unambiguous manner. (i) The following shall be the general applicable markings for gas meters, namely:- (a) Model approval mark (according to Rules); (b) Name or trade mark of the manufacturer; (c) Model designation; (d) Serial number of the gas meter and its year of manufacture; (e) Accuracy class; (f) Maximum flow rate Qmax= … <SI unit>; (g) Minimum flow rate Qmin= … <SI unit>; (h) Transition flow rate Q = … <SI unit> (*); t (i) Gas temperature range and pressure range for which the errors of the gas meter shall be within the limits of the maximum permissible error shall be expressed as: t – t = … - … <SI unit> (*); min max p – p = … - … <SI unit> (*); min max (j) The density range within which the errors shall comply with the limits of the maximum permissible error may be indicated and shall be expressed as: ρ = … - … <SI unit> (*) This marking may replace the range of working pressures unless the working pressure marking refers to a built- in conversion device; (k) Pulse values of HF and LF frequency outputs (imp/<SI unit>, pul/<SI unit>, <SI unit>/imp) (*);[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 89 Note: The pulse value is given to at least six significant figures, unless it is equal to an integer multiple or decimal fraction of the used unit. (l) Character V or H, as applicable, if the meter can be operated only in the vertical or horizontal position; (m) Indication of the flow direction, e.g. an arrow (if applicable, see clause (i) of sub-paragraph (2) of paragraph 5 and clause (ii) of sub-paragraph (2) of paragraph 5; (n) Character M, as applicable, if the meter is designed only to be installed in piping arrangements where only mild flow disturbances may occur; (o) Measurement point for the working pressure according to clause (iv) of sub-paragraph (1) of paragraph 9; and (p) Environmental temperatures, if they differ from the gas temperature as mentioned in sub-clause (i) of clause (i) of sub-paragraph (1) of paragraph 6(*). (ii) Additional markings for gas meters with a built-in conversion device having only one indicating device shall include the following, namely:- (a) Base temperature t = … <SI unit> (*); b (b) Base pressure p =.... <SI unit> (if applicable) (*); b (c) Temperature t = … <SI unit> specified by the manufacturer according to clause (v) of sub-paragraph (3) of sp paragraph 4 (*). (iii) Additional markings for gas meters with output drive shafts shall include the following, namely:- (a) Gas meters fitted with output drive shafts or other facilities for operating detachable additional devices shall have each drive shaft or other facility characterised by an indication of its constant (C) in the form “1 rev = … <SI unit>” and the direction of rotation (“rev” means “revolution”); (b) If there is only one drive shaft the maximum permissible torque shall be marked in the form “M = … max N.mm”; (c) If there are several drive shafts, each shaft shall be characterized by the letter M with a subscript in the form “M , M , …M ”; 1 2 n (d) The following formula shall appear on the gas meter: k M + k M + … + k M ≤ A N.mm; 1 1 2 2 n n where: A is the numerical value of the maximum permissible torque applied to the drive shaft with the highest constant, where the torque is applied only to this shaft; this shaft shall be characterized by the symbol M , 1 k (i= 1, 2, … n) is a numerical value determined as follows: k = C / C, i i 1 i M (i= 1, 2, … n) is the torque applied to the drive shaft characterized by the symbol M, i i C (i= 1, 2, … n) represents the constant for the drive shaft characterized by the symbol M. i i (iv) Additional markings for gas meters with electronic devices shall include the following, namely:- (a) For an external power supply: the nominal voltage and nominal frequency; (b) For a non-replaceable power source: the operational lifetime of the measuring device or, alternatively, the remaining battery capacity in units of time can be specified on the electronic indicating device (*); (c) For a replaceable battery: the latest date by which the battery is to be replaced or, alternatively, the remaining battery capacity shall be specified on the electronic indicating device (*); Note: In case an automatic alarm indicates when the battery life is below 10 %, the above markings are not required.90 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (d) Software identification of the firmware (*). 7. Operating instructions.- (1) Instruction manual,- Unless the simplicity of the measuring instrument makes this unnecessary, each individual instrument shall be accompanied by an instruction manual for the user. However, groups of identical measuring instruments delivered to the same customer do not necessarily require individual instruction manuals. The instruction manual shall be in English language (in addition to English language, Hindi in Devanagri script or other Indian regional languages may be used). The manual shall include the following, namely:- (a) an operating instructions; (b) maximum and minimum storage temperatures; (c) rated operating conditions; (d) warm-up time after switching on the electrical power (if applicable); (e) all other relevant mechanical and electromagnetic environmental conditions; (f) a specification of the required voltage (-range) and frequency (-range) for instruments powered by an external power source; (g) any specific installation conditions, for instance a limitation of the length of signal, data and control lines; (h) if applicable, the specifications of the battery; (i) instructions for installation, maintenance, repair, storage, transport and permissible adjustments (this can be in a separate document, not intended for the user or owner); and (j) conditions for compatibility with interfaces, sub-assemblies (modules) or other measuring instruments. (2) Installation conditions,- The manufacturer shall specify the installation conditions (as applicable) with respect to the following, namely:- (a) the position to measure the working temperature of the gas; (b) filtering; (c) leveling and orientation; (d) flow disturbances (including minimum upstream and downstream pipe lengths); (e) pulsations or acoustic interference; (f) rapid pressure changes; (g) absence of mechanical stress (due to torque and bending); (h) mutual influences between gas meters; (i) mounting instructions; (j) maximum allowable diameter differences between the gas meter and connecting pipe work; (k) other relevant installation conditions. 8. Sealing.-[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 91 (1) Verification marks and protection devices, - (i) General provision,- Protection of the metrological properties of the meter is accomplished via hardware (mechanical) sealing and via electronic sealing wherever possible. In any case, memorised quantities of gas measured (volume or mass) shall be sealed to prevent unauthorised access. (ii) Verification marks,- Verification marks indicate that the gas meter has successfully passed the initial verification; (iii) Hardware sealing (if applicable),- In case of hardware sealing, the location of the marks shall be chosen in such a way that the dismantling of the part sealed by one of these marks results in permanently visible damage to this seal. Locations to be sealed with verification or protection marks shall be provided on the instrument on the following, namely:- (a) On all plates which bear information prescribed by this specification; Note: This requirement is only necessary if the nameplate can be detached from the meter. (b) On all parts of the case which cannot be otherwise protected against interference likely to affect the accuracy of the measurement; and (c) Seals shall be able to withstand outdoor conditions. (iv) Electronic sealing (if applicable),- (a) When the access to parameters that contribute in the determination of result of measurements needs to be protected, and electronic sealing is permitted by the Director of Legal Metrology, the protection shall fulfill the following conditions, namely:- (A) Only the authorised person shall be allowed to enter the configuration mode to modify these parameters using secured means such as a code or password or special device for example (hard key, etc.),- (I) for access prior to changing the parameters after which the instrument may be put into use “in a sealed condition” again without any restriction, or (II) for confirmation after the parameters have been changed, in order to bring the instrument back into service “in sealed condition” (similar to classical or mechanical sealing); (B) The code or password shall be alterable; (C) The device shall either clearly indicate when it is in the configuration mode (not under legal metrological control), or it shall not operate while in this mode. This status shall remain until the instrument has been put into use “in sealed condition” in accordance with item (A) of sub-clause (a) of clause (iv) of sub- paragraph (1) of paragraph 8; (D) Identification data concerning the most recent intervention shall be recorded in an event logger. The record shall include at least,- (I) an identification of the authorised person that implemented the intervention, and (II) an event counter or date and time of the intervention as generated by the internal clock. (E) In addition to the above-mentioned data, the following data is to be stored,- (I) the old value of the changed parameter; and (II) the totals of the registers. The traceability of the most recent intervention shall be assured. In case it is possible to store the records of more than one intervention, and if deletion of a previous intervention must occur to permit a new record, the oldest record shall be deleted.92 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (b) For gas meters of which parts may be disconnected, the following conditions shall be fulfilled, namely:- (A) Access to the parameters that contribute to the determination of results of measurements shall not be possible via a disconnected port unless the conditions in clause (iv) of sub- paragraph (1) are fulfilled; (B) Interposing any device which may influence the accuracy shall be prevented by means of electronic and data processing securities or, if not possible, by mechanical means; (C) Such gas meters shall be equipped with provisions which shall not permit the meter to operate if the parts are not configured in accordance with the manufacturer’s specifications; Note: An unauthorised disconnection (such as by the user) shall be prevented, for example by means of a device that blocks the execution of any measurement after disconnecting and reconnecting. 9. Suitability for testing.- The instrument shall be designed such as to allow initial verification, re-verification and inspection and metrological supervision. (1) Pressure tappings,- (i) General,- If a gas meter is designed to operate above an absolute pressure of 0.15 MPa, the manufacturer shall either equip the meter with pressure tappings, or specify the position of pressure tappings in the installation pipe work. In any case those tappings shall be designed to avoid the effect of potential condensation; Note: This requirement is not mandatory for meters for direct mass measurement or for meters with a built-in pressure sensor. (ii) Bore,- The bore of the pressure tappings shall be large enough to allow correct pressure measurements; (iii) Closure,- Pressure tappings shall be provided with a means of closure to make them gas-tight; (iv) Markings,- The pressure tapping on the gas meter for measuring the working pressure [clause (viii) of sub- paragraph (3) of paragraph 2] shall be clearly and indelibly marked “p ” (the pressure measurement point) or “p” (the pressure m r reference point) and other pressure tappings “p”. Annexure I: Requirements for software controlled Gas Meters (Mandatory) 1 General requirements.- (1) Software identification,- The relevant parts of the software of a gas meter or its constituents or both shall be clearly identified with the software version or any other token. The identification shall apply to at least one part. The identification shall be inextricably linked to the software and shall be,- (i) presented or printed on command; or (ii) displayed during operation; or (iii) displayed at switch-on for those gas meters that can be switched on and off. If a constituent of the gas meter has no display, the identification shall be sent to some other device via a communication interface in order to be displayed on this device.[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 93 As an exception, an imprint of the software identification on the gas meter shall be an acceptable solution if it satisfies the following conditions:- (a) the user interface does not have any control capability to activate the indication of the software identification on the display, or the display does not technically allow the identification of the software to be shown analogue indicating device or electromechanical counter. (b) the gas meter does not have an interface to communicate the software identification. (c) after production of the gas meter a change of the software is not possible, or only possible if the hardware or a hardware component is also changed. The software identification and the means of identification shall be stated in the model approval certificate. (2) Correctness of algorithms and functions,- The measuring algorithms and functions of the gas meter and/or its constituents shall be appropriate and functionally correct. It shall be possible to examine algorithms and functions either by metrological tests, software tests or software examination. (3) Software protection against fraud, - The software part shall be secured against unauthorised modification, loading, or changes by swapping the memory device. In addition to mechanical sealing, technical shall be used to protect gas meters equipped with an operating system or an option to load software. Only clearly documented functions are allowed to be activated by the user interface, which shall be realised in such a way that it does not facilitate fraudulent use. Parameters that fix such characteristics of the gas meter shall be secured against unauthorised modification. For the purpose of verification, displaying of the current parameter settings shall be possible. Note: Device-specific parameters shall be adjustable or selectable only in a special operational mode of the instrument. They may be classified as those that should be secured (unalterable) and those that may be accessed (alterable parameters) by an authorised person, e.g. the instrument owner or product vendor. Software protection comprises appropriate sealing by mechanical, electronic or cryptographic means or a combination of such means making an unauthorised intervention impossible or evident. (i) Support of fault detection, - The detection by the checking facilities of significant faults shall be achieved by software. In such a case, this detecting software is considered relevant. The documentation to be submitted for model approval shall contain a list of the anomalies that might result in a significant fault but that will be detected by the software. The documentation shall include information on the expected reaction and in case the same is essential for understanding its operation, a description of the detecting algorithm. 2. Requirements for specific configurations.- (1) Specifying and separating parts and specifying interfaces of parts,- Metrologically relevant parts of a gas meter, whether software or hardware, shall not be inadmissibly influenced by other parts of the gas meter. This requirement applies if the gas meter and/or its constituents have interfaces for communicating with other electronic devices, with the user, or with other software parts next to the metrological critical parts. (i) Separation of constituents of a gas meter,- (a) constituents of a gas meter that perform functions which are relevant to legal metrology shall be identified, clearly defined, and documented and these shall form the relevant part of the gas meter;94 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (b) it shall be demonstrated that the relevant functions and data of constituents cannot be inadmissibly influenced by commands received via an interface. This implies that there is an unambiguous assignment of each command to all initiated functions or data changes in the constituent. (ii) Separation of software parts,- (a) all software modules (programs, subroutines, objects, etc.) that perform functions which are relevant to legal metrology including data domains are considered to be legal metrology relevant software part of a gas meter. This part shall be made identifiable as specified in sub-paragraph (1) of paragraph (1) of Annexure I. If the separation of the software is not possible, all software is considered relevant. (b) if the relevant software part communicates with other software parts, a software interface shall be defined. All communication shall be performed exclusively via this interface. The relevant software part and the interface shall be clearly documented. All relevant functions and data domains of the software shall be described to enable Director (Legal Metrology) to decide whether this software is sufficiently separated. The interface comprises program code and dedicated data domains. Defined coded commands or data are to be exchanged between the software parts through storing to the dedicated data domain by one software part and reading from it by the other. Writing and reading program code is considered part of the software interface. The data domain forming the software interface shall be clearly defined and documented and include the code that exports from a relevant part to the interface and the code that imports from the interface to the relevant part. The declared software interface shall not be circumvented. The manufacturer shall ensure the compliance of the above conditions respecting these constraints. Technical means (such as sealing) of preventing a program from circumventing the interface or programming hidden commands shall not be possible. The programmer of software part shall be provided with instructions concerning these requirements by the manufacturer. (c) there shall be an unambiguous assignment of each command to all initiated functions or data changes in the relevant part of the software. Commands that communicate through the software interface shall be declared and documented. Only documented commands are allowed to be activated through the software interface. The manufacturer shall state the completeness of the documentation of commands. (d) where legal metrology relevant software has been separated from non-relevant software, the legal metrology relevant software shall have priority using the resources over non-relevant software. The measurement task (realised by the legal metrology relevant software part) must not be delayed or blocked by other tasks. The manufacturer shall ensure the compliance of these conditions. Technical means for preventing a non-relevant program from disturbing relevant functions shall be provided. The programmer of the relevant software part as well as the programmer of the legal metrology non-relevant part shall be provided with instructions concerning these requirements by the manufacturer. (2) Shared indications,- A display shall be employed for presenting information for legal metrology relevant part of software and other information. Software that realises the indication of measurement values and other relevant information shall constitute the relevant part. (3) Storage of data, transmission via communication systems,- If measurement values are used at a location different from the place of measurement or at a stage later than the time of measurement, they may need to be retrieved from the gas meter and be stored or transmitted in an insecure environment before they are used. In such case the following conditions shall apply, namely:-[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 95 (i) The measurement value stored or transmitted shall be accompanied by all relevant information necessary for the future use; (ii) The data shall be protected by software means to guarantee the authenticity, integrity and, if necessary, the correctness of the information concerning the time of measurement. The software that displays or further processes the measurement values and the accompanying data shall check the time of measurement, authenticity, and integrity of the data after having read them from the insecure storage or after having received them from an insecure transmission channel. The memory device shall be fitted with a checking facility to ensure that if an irregularity is detected, the data shall be discarded or marked unusable. Software modules that prepare data for storing or sending, or that check data after reading or receiving are considered part of the software. (iii) When transferring measurement values through an open network, it shall be necessary to apply cryptographic methods. Confidentiality key-codes employed for this purpose shall be kept secret and secured in the measuring instruments, electronic devices, or sub-assemblies involved. Security means shall be provided whereby these keys can only be input or read if a seal is broken. (iv) Transmission delay,- The measurement shall not be influenced by a transmission delay. (v) Transmission interruption,- If communication network services become unavailable, no measurement data shall be lost. The loss of measurement data shall be prevented. (4) Automatic storage,- When, considering the application, data storage is required, measurement data must be stored automatically, i.e. when the final value has been generated. The storage device must have sufficient permanency to ensure that the data are not corrupted under normal storage conditions. There shall be sufficient memory storage for any particular application. All data that are necessary for the calculation shall be automatically stored with the final value. (5) Deleting of data,- Stored data may be deleted when the transaction is settled. Only for settled transaction and in case insufficient memory capacity is available for storage of successive data, it is permissible to delete memorised data subject to the fulfillment of the following conditions, namely:- (a) the sequence of deletion of data shall be in the same order as the recording order and in accordance with the rules established for the particular application; (b) the required deletion shall start either automatically or after a specific manual operation. 3. Maintenance and re-configuration.- Updating the software of a gas meter in service shall be considered as,- (a) a modification of the gas meter, when exchanging the software with another approved version; (b) a repair of the gas meter, when re-installing the same version. A gas meter which has been modified or repaired while in service shall require re-verification. This clause is not applicable to software which has or will have no influence on metrological relevant functions or functioning of the gas meter.96 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] Part 2 Metrological controls and performance tests 10. Metrological controls.- (1) General procedures,- (i) Test method,- All tests shall be carried out under the installation conditions (straight sections of piping upstream and downstream of the meter, flow conditioners, etc.) stipulated by the supplier of the type of meter to be tested. All equipment used and incorporated as part of the execution of the test procedure shall be suitable for the testing of the meter under test. The working range of all equipment and reference standards shall be equal to or exceed that of the meter under test. All reference standards used shall be traceable to national or international standards of measurement. If meters are to be tested in series, there shall be no significant interaction between the meters. This condition shall be verified by testing every meter of the series once at each position in the line. During the tests, corrections shall be made for temperature and pressure differences between the meter under test and the reference standard, otherwise these differences have to be taken into account in the uncertainty calculations. The temperature and pressure measurements have to be performed at a representative position on the meter under test and on the reference standard. (ii) Uncertainty,- When a test is conducted, the expanded uncertainty of the determination of errors of the measured gas quantity shall meet the following specifications, namely:- (a) for model approval : less than one-fifth of the applicable MPE; (b) for verifications : less than one-third of the applicable MPE. However, if the above-mentioned criteria cannot be met, the test results can be approved alternatively by reducing the applied maximum permissible errors with the excess of the uncertainties. In this case the following acceptance criteria shall be used, namely:- (a) for model approval : ± ( ⋅MPE −U) (b) for verifications : ± ( ⋅MPE −U) while U≤ MPE The estimation of the expanded uncertainty U is made with a level of confidence of approx. 95 %. Example: When assuming that during testing for model approval of an accuracy class 1 gas meter the test result has an expanded uncertainty U of 0.3 % (k = 2), the test results may be accepted if the error is between ± (6/5 × 1.0 – 0.3) % = ± 0.9 %. 11. Type evaluation.- (1) General,- A gas meter which is submitted for evaluation is subject to the model approval procedure. Any modification to an approved type not covered by the model approval certificate shall lead to a re-evaluation of the type. The calculator (including the indicating device) and the measuring transducer (including flow, volume or mass sensor) of a gas meter, where they are separable and interchangeable with other calculators and measuring transducers of the same or different designs, may be the subject of separate type evaluations of these parts. A model approval certificate shall be issued only for the complete gas meter. (2) Documentation, -[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 97 (i) Applications for model approval of a gas meter shall be accompanied by the following documents, namely:- (a) Identification of the type, including,- (I) name or trademark of the manufacturer and type designation; (II) version of hardware and software; (III) drawing of name plate. (b) Metrological characteristics of the meter, including,- (I) a description of the principle of measurement; (II) metrological specifications such as accuracy class and rated operating conditions; (III) any steps which should be performed prior to testing the meter. (c) The technical specification for the meter, including,- (I) a block diagram with a functional description of the components and devices; (II) drawings, diagrams and general software information, explaining the construction and operation, including interlocks; (III) description and position of seal or other means of protection; (IV) documentation related to durability characteristics; (V) specified clock frequency; (VI) any document or other evidence that supports the assumption that the design and construction of the meter complies with the requirements. (d) user manual; (e) installation manual; (f) a description of the checking facilities to prevent occurring of significant faults, if applicable. (ii) In addition, if software is in use the documentation shall include,- (a) a description of the relevant software and how the requirements are met, comprising of,- (I) a list of software modules that belong to the relevant part including a declaration that all relevant functions are included in the description; (II) a description of the software interfaces of the relevant software part and of the commands and data flows via this interface including a statement of completeness; (III) a description of the generation of the software identification; (IV) depending on the validation method chosen, the source code; (V) a list of parameters to be protected and description of protection means; (b) a description of a suitable hardware system configuration and minimal required resources for the software to operate as intended; (c) a description of security means for protection of entering the operating system (password, etc. if applicable); (d) a description of the software sealing method; (e) an overview of the system hardware, e.g. topology block diagram, type of computers, type of network, etc.; (f) identification of those hardware components that perform relevant functions; (g) a description of the accuracy of the algorithms (e.g. filtering of A/D conversion results, price calculation, rounding algorithms, etc.); (h) a description of the user interface, menus and dialogues; (i) identification of the software and instructions for obtaining this identification from an instrument in use; (j) list of commands of each hardware interface of the measuring instrument (or its constituents) including a statement of completeness;98 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (k) list of potential significant errors that will be detected and acted upon by the software and if necessary for understanding, a description of the detecting algorithms; (l) a description of data sets stored or transmitted; (m) if fault detection is realised in the software, a list of faults that are detected and a description of the detecting algorithm; (n) the operating manual. (3) Design inspection,- Each type of gas meter submitted shall be inspected externally to ensure that it complies with the provisions of the relevant preceding clauses of these requirements. (4) Number of specimens,- The applicant shall deliver the requested number of specimens of gas meters, manufactured in conformity with the type, at the disposal of the Director (Legal Metrology) for type evaluation. If so requested by the Director (Legal Metrology) responsible for the type evaluation, these meters shall include more than one size (preferably all the sizes) if simultaneous approval of a family of gas meters is requested (See Annexure D: Model approval of a family of gas meters). Depending on the results of the tests, the Director (Legal Metrology) responsible for the model approval may request further specimens. In order to accelerate the test procedure, the testing laboratory may carry out different tests simultaneously on different units. In this case, the testing laboratory shall ensure that all submitted instruments are of the same type. In general all accuracy and influence tests shall be performed on the same unit, but disturbance tests may be carried out on additional instruments. In this case, the testing laboratory decides which test to be carried out on which unit. If a specimen does not pass a specific test and as a result needs to be modified or repaired, the applicant shall apply this modification to all the specimens submitted for the test. These modified specimens shall again be subjected to this particular test. If the testing laboratory has well-founded reasons to believe that the modification could have a negative impact on the result of another test or tests already performed, these tests shall be repeated as well. (5) Model approval procedures,- (i) Software evaluation,- The software evaluation procedure concerns evaluation of compliance to the requirements as specified in part 1 of Annexure I and comprises a combination of analysis and validation methods and tests as specified in Table 6. The explanation of the abbreviations used and the relation to the methods as described in detail is specified in Table 7. Table 6. Software validation procedures applicable for verification of compliance Serial Requirement Evaluation procedure No. (1) (2) (3) (4) (a) Sub-paragraph (1) of Software identification AD + VFTSw paragraph 1 of Annexure I (b) sub-paragraph (2) of Correctness of algorithms AD + VFTSw paragraph 1 of Annexure I (c) sub-paragraph (3) of Fraud protection AD+VFTSw+DFA/CIWT/SMT1 paragraph 1 of Annexure I (d) Parameter protection AD+VFTSw+DFA/CIWT/SMT1[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 99 (e) sub-paragraph (2) of Separation of electronic devices and AD paragraph 2 of sub-assemblies Annexure I (f) sub-paragraph (3) of Separation of software parts AD paragraph 2 of Annexure I (g) sub-paragraph (3) of Storage of data, transmission via AD + VFTSw + CIWT/SMT1 paragraph 2 of communication systems Annexure I (h) clause(i) of sub- Data protection with respect to time of AD + VFTSw + SMT1 paragraph (3) of measurement paragraph 2 of Annexure I (i) sub-paragraph (4) of Automatic storage AD + VFTSw paragraph 2 of Annexure I (j) clause(iv) of sub- Transmission delay AD + VFTSw paragraph (3) of paragraph 2 of Annexure I (k) clause(v) of sub- Transmission interruption AD + VFTSw paragraph (3) of paragraph 2 of Annexure I (l) Time stamp AD + VFTSw Table 7. Cross references of evaluation procedures to those specified in Annexure E Serial No. Abbreviation Description Related Annex E (1) (2) (3) (4) (a) AD Analysis of the documentation and Annexure E (E1) validation of the design (b) VFTM Validation by functional testing of Annexure E (E2) metrological functions (c) VFTSw Validation by functional testing of software Annexure E (E3) functions (d) DFA1 Metrological data flow analysis Annexure E (E4) (e) CIWT1 Code inspection and walkthrough Annexure E (E5) (f) SMT1 Software module testing Annexure E (E6) (1) If one of the three cases below applies, the execution of the evaluation methods DFA, CIWT and SMT is not necessary,- Case 1: no data transmission interface is incorporated in the gas meter, or Case 2: a transmission interface is incorporated but only provides measurement data output from the gas meter, or Case 3: no transmission of measurement data in open systems is possible. (ii) Hardware evaluation,- (a) Reference conditions,- All influence quantities, except for the influence quantity being tested, shall be kept to the following values during model approval tests on a gas meter: Working (gas/air) temperature: (20.0 ± 5.0) °C; Ambient temperature: (20.0 ± 5.0) °C;100 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] Ambient atmospheric pressure: 86 kPa – 106 kPa; Ambient relative humidity: 60 % ± 25 %; Power voltage (AC/DC mains),- *if one nominal voltage is specified: this specified nominal voltage (U ); nom *if a voltage range is specified: a typical voltage within this range, to be negotiated between the manufacturer and the testing laboratory; Power voltage (battery): the nominal voltage of a new or fully charged battery (not under charge); Power frequency (AC mains): nominal frequency (f ). nom Note: High pressure tests may be performed at conditions other than reference conditions. (b) Flow rates,- The flow rates at which the errors of the gas meters need to be determined shall be distributed over the measuring range at regular intervals and include Q and Q and preferably Q. min max t Based on three test points per decade the minimum number (N) of test points, ranking from i= 1 to i= N can be calculated according to,- N = 1+3. Log Where N ≥ 6, and rounded to the nearest integer. For flow rates covering two decades or more, the following formula presents an adequate regular distribution of flow rates for i= 1 to i= N–1 and Q = Q . N min Q= ( )1-i.Q i max (c) Test gases,- (I) Required gases for model approval tests,- All the tests listed in sub-paragraph (6) of paragraph 11 may be performed with air or any other gas as specified by the manufacturer under the rated operating conditions stated in sub-paragraph (1) of paragraph 4. For the temperature tests in clause (vii) of sub-paragraph (6) of paragraph 11, it is important that the gas be dry. Gas meters intended to measure different gases (as stated in clause (xii) of sub-paragraph (6) of paragraph 11) are to be tested with the gases specified by the manufacturer. (II) Evaluation for the use of an alternative test gas during verification,- When gas meters are to be verified (at initial or re-verification) with air the model approval test as stated in clause (xiii) of sub-paragraph (6) of paragraph 11 shall include air. When gas meters are to be verified with a type of gas different from that at operating conditions, the model approval test as stated in clause (iii) of sub-paragraph (6) of paragraph 11 shall include such type of gas. In both the above cases the maximum differences between the error curves of the intended test gas and the gas in-use are calculated and the need to use correction factors during verification test (see sub-clause (c) of clause (iv) of sub-paragraph (1) of paragraph 12) is established as follows,- (a) If these differences stay within 1/3 MPE, the initial error-verification may be performed with the alternative gas. (b) If these differences exceed 1/3 MPE, the initial or re-verification shall be performed with the alternative gas if a correction for the differences is applied.[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 101 The Director (Legal Metrology) responsible for model approval shall document whether the initial or re- verification may be performed with air [or the other gases] and whether correction factors must be applied. (6) Model approval tests,- During the model approval gas meters are tested while applying the requirements as stated in paragraph 4. Annexure C shows an overview of the required tests for different measurement principles. (i) Error,- The error of the gas meter shall be determined, while using the flow rates according to the prescriptions stated in sub-clause (b) of clause (ii) of sub-paragraph (5) of paragraph 11. The error curve as well as the WME [clause (v) of sub-paragraph (2) of paragraph 2] shall be within the requirements as specified in sub-paragraph (3) of paragraph 4 and sub-paragraph (4) of paragraph 4, respectively. If a curve fit is made out of the observations, a minimum of 6 degrees of freedom is required. Note: The number of degrees of freedom is the difference between the number of observations and the number of parameters or coefficients needed for the curve fit. For example, if a polynomial curve fitting is used with 4 coefficients, at least 10 measuring points are necessary in order to obtain a minimum of 6 degrees of freedom. During the accuracy test applied on the gas meter, the following quantities shall be determined,- (a) the cyclic volume of the gas meter, if applicable, according to the provisions of the last sentence in clause (ii) of sub-paragraph (4) of paragraph 5. (b) the pulse factor of the gas meter, if applicable, according to the provisions of clause (iii) of sub-paragraph (4) of paragraph 5. (ii) Reproducibility,- Compliance with the reproducibility of error requirement stated in sub-paragraph (6) of paragraph 4 is determined at the flow rates in conformity with sub-clause (b) of clause (ii) of sub-paragraph (5) of paragraph 11, equal to or greater than Q. For each of these flow rates, the errors shall normally be determined six times t independently, while varying the flow rate between each consecutive measurement. The reproducibility of error at each flow rate shall be determined. In case the reproducibility of error of the first three measurements is equal to or smaller than 1/6 MPE the requirement is deemed to be met. Note: For gas meters which are intended to be used at high pressures, this test may be performed at the lowest operating pressure. (iii) Repeatability,- Compliance with the repeatability of error requirement stated in sub-paragraph (7) of paragraph 4 is determined at the flow rates Q , Q, and Q . At each of these flow rates, the errors are determined three times and the min t max difference between the minimum and maximum measured error is calculated. Note: For gas meters which are intended to be used at high pressures, this test may be performed at the lowest operating pressure. (iv) Orientation, - Unless specified by the manufacturer that the gas meter is to be used only in certain mounting orientations, it shall be established whether the orientation of the meter influences the measuring behavior. The following orientations shall be examined,- (a) horizontal, (b) vertical flow-up, (c) vertical flow-down, and the accuracy measurements as stated in clause (i) of sub-paragraph (6) of paragraph 11 are performed in these orientations. If only certain orientations are stipulated by the manufacturer only those orientations shall be examined.102 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] The results of the different accuracy measurements are evaluated with the requirements as specified in clause (i) of sub-paragraph (13) of paragraph 4 without intermediate adjustments. If the requirements are not fulfilled for all prescribed orientations without intermediate adjustments, the meter shall be marked in order to be used in a certain orientation only, as specified in sub-clause (l) of clause (i) of sub- paragraph (1) of paragraph 6. (v) Flow direction,- The accuracy measurements as stated in clause (i) of sub-paragraph (6) of paragraph 11 shall be performed in both flow directions, if applicable. The results of the different accuracy measurements shall be evaluated with the requirements as specified in clause (ii) of sub-paragraph (13) of paragraph 4 without intermediate adjustments. If the requirements are not fulfilled for both flow directions without intermediate adjustments, the meter shall be marked in order to be used in a certain direction only, as specified in sub-paragraph (2) of paragraph 5. (vi) Working pressure,- The accuracy measurements as stated in clause (i) of sub-paragraph (6) of paragraph 11 are performed at least at the minimum and at the maximum operating pressure. The results of the different accuracy measurements are evaluated with the requirements as specified in sub- paragraph (8) of paragraph 4 without intermediate adjustments. If the requirements are not fulfilled for the operating pressure range without intermediate adjustments, when putting into use either the operating pressure range shall be reduced or the operating pressure range shall be split into several ranges. Alternatively pressure correction shall be applied. For technologies that are proven to be insensitive to pressure or diaphragm meters, this test is not applicable. (vii) Temperature,- (a) The temperature dependency of the gas meter shall be evaluated in the temperature range specified by the manufacturer, by one of the methods stated below, ranked in the following preferred order, namely:- (I) flow tests at different temperatures,- The flow tests are performed with a gas temperature equal to the ambient temperature as specified in sub- clause (b) of clause (vii) of sub-paragraph (6) of paragraph 11. For gas meters with a built-in conversion device showing the volume at base conditions only also the flow tests are to be performed with a gas temperature different from the ambient temperature as specified in sub-clause (c) of clause (vii) of sub- paragraph (6) of paragraph 11. (II) monitoring the unsuppressed flow rate output of the meter at no-flow conditions at different temperatures,- At no-flow conditions, the unsuppressed flow rate output of the meter is used in order to determine the temperature influence on the meter accuracy. The examination is performed at least at the reference temperature, and at the minimum and maximum operating temperatures. The results of the measurements at the different temperatures are evaluated with the requirements as specified in sub-paragraph (9) of paragraph 4, while taking into account the influence of the flow rate shift on the meter curve. Example: The unsuppressed flow rate output of an accuracy class 1 gas meter is changed with +1 L/h due to temperature variations. The initial error at reference conditions of this meter was +0.3 % at a Q of 200 min L/h. The influence due to temperature variations at Q is 1/200 × 100 % = + 0.5 %. The final value of + min 0.8 % remains within the limits of the applicable maximum permissible error. Note: The unsuppressed flow rate is defined as the flow rate at which the low flow cut-off (if present) is not active. (III) evaluation of the construction of the meter,-[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 103 In cases when the meter cannot be tested to determine the effect of temperature, the uncertainty resulting from the expected influence of temperature on the meter construction shall be evaluated. For residential meters, flow tests are mandatory as specified in item (I) of sub-clause (a) of clause (vii) of sub-paragraph (6) of paragraph 11. (b) flow tests with equal gas and ambient temperatures,- The flow tests are performed at the flow rates specified in sub-clause (b) of clause (ii) of sub-paragraph (5) of paragraph 11, in the range Q up to Q , with the gas temperature equal to the ambient temperature t max (within 5 °C), sequentially at, - (I) reference temperature; (II) maximum ambient temperature; (III) minimum ambient temperature; (IV) reference temperature. The requirements as specified in sub-paragraph (9) of paragraph 4 for equal gas and ambient temperature shall be complied. (c) flow tests with unequal gas and ambient temperatures,- The flow tests are performed while keeping the gas meter under test at a constant ambient temperature equal to the reference temperature and sequentially, namely:- (I) the gas temperature at 40° C; (II) the gas temperature at 0 °C. The error is determined at Qt and Qmax. Determination of errors shall be performed only after the temperature of the gas is stabilised. The requirements for unequal gas and ambient temperature as specified in sub-paragraph (9) of paragraph 4 shall be complied. Note: Instead of the above-mentioned temperature test, alternatively the test may be performed while using the following temperature conditions: 1. gas temperature at 20 °C and the gas meter at 40° C; 2. gas temperature at 20 °C and the gas meter at 0 °C. (viii) Flow disturbance,- Gas meters of which the accuracy is affected by flow disturbances shall be submitted to the tests as specified in Annexure B. During the tests the meters shall be installed according to the manufacturer’s specifications. If such gas meters are specified and marked not to be inserted in piping arrangements producing severe disturbances they shall only be tested according to Annexure B B2 (Mild flow disturbances). The piping arrangements as specified in Table B.1 shall be followed, tests given at (a) to (g) in the said table are considered to produce only mild flow disturbances. The requirements as specified in clause (iii) of sub-paragraph (13) of paragraph 4 shall be complied. (ix) Durability,- All gas meters with internal moving parts and gas meters without internal moving parts having a maximum equivalent volume flow rate up to and including 25 m3/h are submitted to the durability test. This test comprises exposure to a continuous flow during the required period of time, while using gases for which the meters are intended to be used. In case the manufacturer has demonstrated that the material composition of the gas meter is sufficiently insensitive to the gas composition, the Director (Legal Metrology) responsible for the model approval may decide to perform the durability test with air or another suitable type of gas. The applied flow rate is at least 0.8 Q . This test shall be performed at the minimum working pressure. max Before and after the test, the same reference equipment shall be used.104 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] Director (Legal Metrology) responsible for the model approval shall choose the number of meters of the same type to be submitted for the durability test from the options given in Table 8 in consultation with the applicant. If different sizes are included, the total number of meters to be submitted shall be as specified in option 2. Table 8. Number of meters to be tested Serial Maximum equivalent volume flow Number of meters to be tested No. rate [m3/h] Option 1 Option 2 (1) (2) (3) (4) (a) Q ≤ 25 3 6 max (b) 25 <Q ≤ 100 2 4 max (c) Q > 100 1 3 max After the durability test the gas meters are tested at flow rates as determined in sub-clause (b) of clause (ii) of sub-paragraph (5) of paragraph 11. The gas meters shall comply with the requirements specified in sub-paragraph (10) of paragraph 4 (with the exception of one of them if the durability test has been carried out on a number of gas meters according to option 2). (x) Drive shaft (torque),- Gas meters with drive shafts are submitted to the maximum possible torque, while using a gas at a density of 1.2 kg/m3. The fault is evaluated at Qmin. The requirements as specified in clause (iv) of sub-paragraph (13) of paragraph 4 shall be complied. Where a type of gas meter includes various sizes, this test only needs to be carried out on the smallest size, provided that the same torque is specified for the larger gas meters and the drive shaft of the larger gas meter has the same or greater output constant. (xi) Overload flow,- Gas meters with internal moving parts are submitted to the overload flow. Before and after the overload, the error of the gas meter is determined for its whole flow rate range in accordance with sub-clause (b) of clause (ii) of sub-paragraph (5) of paragraph 11. The requirements as specified in sub-paragraph (11) of paragraph 4 shall be complied. (xii) Different gases,- Gas meters which are intended to be used for different gases are submitted to accuracy measurements as specified in clause (i) of sub-paragraph (6) of paragraph 11 with the gases specified by the manufacturer. Taking into consideration the manufacturer’s proposal, the Director (Legal Metrology) responsible for the model approval shall decide the gases that are to be used during the examination, depending on the application purpose of the gas meter under test. The requirements as specified in clause (v) of sub-paragraph (13) of paragraph 4 shall be complied. If the requirements are not fulfilled for all different gases without intermediate adjustments, the Director (Legal Metrology) responsible for model approval shall report on this observation and specify this range of operating gases for which the gas meter has fulfilled the requirements. (xiii) Vibration and shocks,- Gas meters having a maximum mass of 10 kg are submitted to vibrations and shocks. For gas meters exceeding this weight only the electronic part of the meter is to be tested. Before and after these tests the added intrinsic error of the gas meter is determined according to sub-clause (b) of clause (ii) of sub- paragraph (5) of paragraph 11 over the whole flow rate range. The requirements as specified in sub-paragraph (12) of paragraph 4 shall be complied. (xiv) Interchangeable components,-[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 105 For gas meters of which some components are intended to be interchangeable, as specified by the manufacturer, the influence of interchange shall be determined at Q. t Note: The maximum permissible error limits of the upper flow range apply. (Q ≥ Q) t This accuracy test shall be performed at each of the three stages in the following sequence,- (a) while using the starting configuration; (b) after interchange of the component; (c) after reinstalling the original component. The fault shall be established by calculating the maximum difference between the results of any of the three accuracy tests. The requirements as specified in clause (vi) of sub-paragraph (13) of paragraph 4 shall be complied. (xv) Electronics,- For gas meters containing electronic components, the requirements as specified in clause (vii) of subparagraph (13) of paragraph 4 shall also be complied. Performance tests shall be executed using the test methods specified in Part 2, and ensuring compliance of the requirements specified in Table 4 and Table 5. After each test it shall be verified that no loss of data has occurred. If the electronic devices of a gas meter are located in a separate housing, their electronic functions shall be tested independently of the measuring transducer of the gas meter by simulated signals representing the rated operating conditions of the meter. In this case the electronic devices shall be tested in their final housing. In all cases, ancillary equipment may be tested separately. The tests as specified in Table 4 and Table 5 shall be performed under the following conditions, namely:- (a) the meter under test is powered up, except when performing the vibration and mechanical shock test; (b) the dependency of the gas meter’s performance shall be evaluated in one of the flow modes stated below, ranked in the following preferred order:- (I) during actual flow, or (II) at no-flow conditions while monitoring the unsuppressed flow rate output of the meter. In the latter case, compliance with the requirements indicated in Table 4 and Table 5 is checked while taking into account the influence of the flow rate shift on the meter curve. Note: Most electronic meters have a cut-off for low flow rates. This cut-off must be switched off for this test so that the flow rate output corresponds to the unsuppressed flow rate. (xvi) Influences from ancillary devices, - The effect of all functions of ancillary devices is determined by performing an accuracy test at Q , with min and without applying the specific function. The effect shall be negligible (=< 0.1MPE). (7) Model approval certificate,- The following information and data shall appear on the model approval certificate, namely:- (a) name and address of the company to whom the model approval certificate is issued; (b) name of the manufacturer; (c) type of the gas meter or commercial designation; (d) principal metrological and technical characteristics, such as accuracy class, units of measurement, values of Qmax, Qmin and Qt, the rated operating conditions as specified in sub-paragraph (1) of paragraph 5, maximum working pressure, nominal internal diameter of the connecting pieces and, in the case of volumetric gas meters, the nominal value of the cyclic volume;106 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (e) model approval mark; (f) period of validity of the model approval (if applicable); (g) for meters equipped with drive shafts, the characteristics of the drive shafts; (h) environmental classification; (i) information on the location of the marks and inscriptions required in sub-paragraph (1) of paragraph 6, initial verification marks and seals (where applicable, in the form of photographs or drawings); (j) list of the documents accompanying the model approval certificate; (k) any special comments. 12. Initial verification and re-verification.- (1) General,- The object of the initial verification is to verify the compliance of the individual gas meter with the following requirements before putting the same into service,- (i) suitable and sufficient accurate measurement references shall be used during such assessments. (ii) the calibration of these references shall be valid and traceable to national and international measurement standards. (iii) applicable examinations and tests may be carried out at the production plant of the gas meter on the ultimate mounting location or on any other intermediate testing site that provides sufficient and adequate means for performing the required examinations and tests. (iv) the following measures shall be carried out for verification,- (a) conformity with the approved type: A gas meter shall be examined to ascertain whether it conforms to its approved type; (b) submission: A gas meter shall be operational when submitted for initial verification and the required space shall be available on the meter for placing the verification mark and sealing; (c) test conditions: The accuracy requirements of sub-paragraph (3) of paragraph 4 and sub-paragraph (4) of paragraph 4 shall be verified while the gas conditions are kept as close as possible to the intended operating conditions (pressure, temperature, gas type) of the meter after being put into use. The verification may also be performed with a type of gas (e.g. air) other than the type for which the meter is intended to be used, if the authorities responsible for the verification are convinced that comparable results will be gained by either the outcome of the evaluation test with different gases [see sub-clause (c) of clause (ii) of sub-paragraph (5) of paragraph 11] or by the technical construction of the meter under test. If needed, correction factors for the differences between the gases shall be applied; (d) flow rates: A gas meter shall be tested at the flow rates specified in sub-clause (b) of clause (ii) of sub-paragraph (5) of paragraph 11.[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 107 The initial verification may be performed at a reduced number of flowrates, provided this option is supported by instructions for performing the verifications [see sub-paragraph (8) of paragraph 11]. Note 1: Verification of diaphragm gas meters in all cases is restricted to performance of tests at the flow rates Q , 0.2·Q and Q . max max min Note 2: The number of test points concerning rotary piston gas meters may be reduced on the direction of Director (Legal Metrology). (e) orientation and flow direction: If the gas meter can be used in more than one flow direction or meter orientation, the verification shall be performed in both flow directions and the meter orientations specified by the manufacturer, unless during the model approval it was examined, proven and reported in the approval certificate that the meter performance is independent from the meter orientation (requirement of clause (i) of sub-paragraph (13) of paragraph 4 is fulfilled) or the flow direction or both (requirement of clause (ii) of sub-paragraph (13) of paragraph 4 is fulfilled). (f) adjustments: If the error curve or the WME does not fulfill the requirements specified in sub- paragraph (3) of paragraph 4 and sub-paragraph (4) of paragraph 4 respectively, the gas meter shall be adjusted such that the WME is as close to zero as the adjustment and the maximum permissible error allow. Note 1: After changing the adjustment while using single point adjustment it is not necessary to repeat all the tests. It is sufficient to repeat a test at one flow rate and calculate the other error values from the previous ones. Note 2: For high pressure applications, adjustment is performed while taking into account the operating conditions. (g) output shafts: If the gas meter is intended to incorporate ancillary devices operated by the output shafts, these devices shall be attached during the verification, unless attachment after verification is explicitly authorised. (2) For the purpose of additional requirements for in-service inspections or re- verifications, the following meters shall include,- (i) Volumetric Meters includes those with integrated pulse initiators, remote registers (indexes), remote meter- reading or automatic meter-reading (AMR) devices, correction devices or linearisation functions (the “linearisation” function may either be incorporated into the circuit design of an electronic volumetric meter or a flow computer, or in a separate correcting device), event loggers and audit trail functions, and electronic volume conversion functions. (ii) Mass-flow Meters includes those with integrated pulse initiators, remote indexes, remote meter-reading or automatic meter-reading (AMR) devices, and event loggers. (iii) Base Pressure and Temperature Conversion devices or Recording devices includes those with integrated pulse initiators, remote-meter-reading or automatic-meter-reading devices, and those incorporating event loggers and audit trail functions. Annexure A: Environmental tests for electronic instruments or devices (Mandatory) 1. General,- This annexure specifies the performance tests intended to verify the gas meters containing electronics and their ancillary devices and the functions they may perform in the specified environment and under specified conditions. Each test indicates, where appropriate, the reference conditions for determining the error. These tests supplement any other prescribed tests. When the effect of one influence quantity is being evaluated, all other influence quantities are to be kept within the limits of the reference conditions.108 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] 2. Test levels,- For each performance test, typical test conditions are specified. These correspond to the climatic and mechanical environment conditions to which instruments are usually exposed. The testing laboratory shall carry out performance tests at the test levels corresponding to these environmental conditions. 3. Reference conditions,- As specified in sub-clause (a) of clause (ii) of sub-paragraph (5) of paragraph 11. 4. Performance tests (climatic),- (1) Static temperatures,- Table 1. (i) Dry heat (non-condensing): influence test,- Object of the test Verification of compliance under conditions of high environmental temperature. (1) (2) Test procedure in brief The test comprises exposure to the specified high temperature under “free air” conditions for the time specified (the time specified is the time after the equipment under test has reached temperature stability). The change of temperature shall not exceed 1 °C/min during heating up and cooling down. The absolute humidity of the test atmosphere shall not exceed 20 g/m3. When testing is performed at temperatures lower than 35 °C, the relative humidity shall not exceed 50 %. Temperature upper temperature specified °C Duration 2 H Table 2. (ii) Cold: influence test,- Object of the test Verification of compliance under conditions of low environmental temperature. (1) (2) Test procedure in brief The test comprises exposure to the specified low temperature under “free air” conditions for the time specified (the time specified is the time after the equipment under test has reached temperature stability). The change of temperature shall not exceed 1 °C/min during heating up and cooling down. International Electrotechnical Commission specifies that the power to the equipment under test shall be switched off before the temperature is raised. Temperature lower temperature specified °C Duration 2 H (2) Damp heat,- Table 3. (i) Damp heat, steady-state (non condensing): influence test,- Object of the test Verification of compliance under conditions of high environmental humidity and constant temperature. (1) (2) Test procedure in brief The test comprises exposure to the specified temperature and the specified constant relative humidity for a certain fixed period of time. The equipment under test shall be handled such that no condensation of water occurs on it. The gas meter shall be subjected 3 times to an accuracy test: - at reference conditions, before the increase of temperature; - at the end of the upper temperature phase;[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 109 - at reference conditions, 24 hours after the decrease of temperature. Temperature upper temperature specified °C Relative humidity (RH) 93 % Duration 4 H Table 4. (ii) Damp heat, cyclic (condensing): disturbance test,- Object of the test Verification of compliance under conditions of high environmental humidity combined with cyclic temperature changes. (1) (2) Test procedure in brief The test comprises exposure to cyclic temperature variation between 25 °C and the appropriate upper temperature while maintaining the relative humidity above 95 % during the temperature change and low temperature phases, and at or above 93 % at the upper temperature phases. Condensation is expected to occur on the equipment under test during the temperature rise. The 24 hours cycle consists of: (1) Temperature rise during 3 hours. (2) Temperature maintained at upper temperature level until 12 hours from the start of the cycle. (3) Temperature lowered to the lower temperature level within a period of 3 to 6 hours, the rate of fall during the first hour and a half being such that the lower temperature level would be reached in 3 hours. (4) Temperature maintained at lower temperature level until the 24 hours cycle is completed. The stabilizing period before and recovery period after the cyclic exposure shall be such that the temperature of all parts of the equipment under test is within 3 °C of its final value. During the test the instrument is switched on, gas flow is not required. The gas meter shall be subjected to an accuracy test both,- (a) at reference conditions, before the increase of temperature, and (b) at reference conditions, at least 4 hours after the last cycle. Upper temperature upper temperature specified °C Duration 2 Cycles 5. Performance tests (mechanical),- Table 5. (1) Vibration (random): disturbance test,- Object of the test Verification of compliance under conditions of random vibration. (1) (2) Test procedure in brief The test comprises exposure to the level of vibration for the time specified. The equipment under test shall, subsequently, be tested in three mutually perpendicular axes mounted on a rigid fixture by its normal mounting means. The equipment under test shall normally be mounted in such a way that the gravity vector points in the same direction as it would do in normal use. Where, based on the metering principle the effect of gravitational force can be assumed negligible the equipment under test may be mounted in any position. Example: a diaphragm gas meter always has to be tested in an upright position, for each direction in which the meter has to be tested. During the test the instrument is not required to be powered up (switched on).110 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] Total frequency range 10 Hz – 150 Hz Total RMS level 7 m·s-2 ASD level 10 Hz – 20 Hz 1 m2·s-3 ASD level 20 Hz – 150 Hz –3 dB/octave Number of axes 3 Duration per axis 2 minutes Table 6. (2) Mechanical shock: disturbance test,- Object of the test Verification of compliance under conditions of mechanical shocks. (1) (2) Test procedure in brief The equipment under test, placed in its normal position of use on a rigid surface, is tilted towards one bottom edge and is then allowed to fall freely onto the test surface. The height of fall is the distance between the opposite edge and the test surface. However, the angle made by the bottom and the test surface shall not exceed 30°. During the test the instrument is not powered up. Height of fall 50 mm Number of falls (on each 1 bottom edge) 6. Performance tests (electrical, general),- (1) Radio frequency immunity tests,- Table 7. (i) Radiated, radio frequency, electromagnetic fields: disturbance test,- Object of the test Verification of compliance of the equipment under test while being exposed to radio frequency electromagnetic fields. (1) (2) Test procedure in brief The equipment under test is exposed to electromagnetic fields having the required field strength level specified and the field uniformity as defined in the reference standard. The equipment under test shall be exposed to the modulated wave field. The frequency sweep shall be performed only pausing to adjust the radio frequency signal level or to switch radio frequency-generators, amplifiers and antennas if necessary. Where the frequency range is swept incrementally, the step size shall not exceed 1 % of the preceding frequency value. The dwell time of the amplitude modulated carrier at each frequency shall not be less than the time necessary for the equipment under test to be exercised and to respond, but shall in no case be less than 0.5 s. The expected most critical frequencies (e.g. clock frequencies) shall be analyzed separately (1). Frequency range 80 MHz – 3 GHz (2), (4) 26 MHz – 3 GHz (3) Field strength 10 V/m Modulation 80 % AM, 1 kHz, sine wave Notes (1) Usually, these sensitive frequencies can be expected to be the frequencies emitted by the equipment under test. (2)This test only specifies test levels above 80 MHz. For frequencies in the lower range the test methods for conducted radio frequency disturbances are preferred (see clause (ii) of sub-paragraph (1) of paragraph 6 of Annexure A). (3) For equipment under test lacking any cabling as is needed for applying the test[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 111 specified in clause (ii) of sub-paragraph (1) of paragraph 6 of Annexure A, the lower frequency limit for this test (see clause (i) of sub-paragraph (1) of paragraph 6) shall be 26 MHz (In all other cases both clause (i) and clause (ii) of sub- paragraph (1) of paragraph 6 of Annexure A shall apply). (4) For the frequency range 26 MHz – 80 MHz, the testing laboratory can either carry out the test according to clause (i) of sub-paragraph (1) of paragraph 6 of Annexure A or according to clause (ii) thereof. But in the event of a dispute, the results according to clause (ii) of sub-paragraph (1) of paragraph 6 of Annexure A shall prevail. Table 8. (ii) Conducted radio-frequency fields: influence test,- Object of the test Verification of compliance of the equipment under test while being exposed to radio frequency electromagnetic fields (1) (2) Test procedure in brief Radio frequency electro-magnetic current, simulating the influence of electro- magnetic fields shall be coupled or injected into the power ports and input/ output ports of the equipment under test using coupling/decoupling devices. The performance of the test equipment consisting of a radio frequency generator, (de-)coupling devices, attenuators, etc. shall be verified. radio frequency amplitude (50 10 V (e.m.f.) Ω ) Frequency range 0.15 – 80 MHz Modulation 80 % AM, 1 kHz, sine wave Notes (1) This test is not applicable for when the equipment under test has no mains power supply or other copper wired input/output port. (2) If the equipment under test comprises several devices, the tests shall be performed at each extremity of the cable if both devices are part of the equipment under test. (3) For the frequency range 26 MHz – 80 MHz, the testing laboratory can either carry out the test in accordance with clause (ii) of sub-paragraph (1) of paragraph 6 of Annexure A or clause (i) thereof. But in the event of a dispute, the results in accordance with clause (ii) of sub- paragraph (1) of paragraph 6 of Annexure A shall prevail. Table 9. (2) Electrostatic discharge: disturbance test,- Object of the test Verification of compliance in case of direct exposure to discharging of electrostatic charged objects or persons on the equipment under test of such discharges in the neighborhood of the equipment under test. (1) (2) Test procedure in brief An electro static discharge generator shall be used and the test setup shall comply with the dimensions, materials used and conditions as specified in this standard. Before starting the tests, the performance of the generator shall be verified. At each pre-selected discharge location on the equipment under test at least 10 discharges shall be applied. The time interval between successive discharges shall be at least 1 second. For equipment under tests not equipped with a ground terminal, the equipment under test shall be fully discharged between the discharges applied using the electro static discharge generator. Contact discharge is the preferred test method. As Air discharges are less reproducible, these shall be used only where contact discharge cannot be applied. Direct application: In the contact discharge mode to be carried out on conductive surfaces, the112 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] electrode shall be in contact with the equipment under test. In the air discharge mode on insulated surfaces, the electrode shall be brought in contact with the equipment under test and the discharge occurs by spark. Indirect application: The discharges are applied in the contact mode to coupling planes mounted in the vicinity of the equipment under test. Test voltage Contact discharge (1) 6 kV Air discharge (1) 8 kV Notes (1) Contact discharges shall be applied on conductive surfaces. Air discharges shall be applied on non-conductive surfaces. Table 10. (3) Bursts (transients) on signal, data and control lines: disturbance test,- Object of the test Verification of compliance of the equipment under test to conditions where electrical bursts are superimposed on input/output and communication ports. (1) (2) Test procedure in brief A burst generator shall be used The characteristics of the generator shall be verified before connecting the equipment under test. The test comprises the exposure to bursts of voltage spikes for which the repetition frequency of the impulses and peak values of the output voltage on 50 Ω and 1,000 Ω load. The characteristics of the generator shall be verified before connecting the equipment under test. Both positive and negative polarity of the bursts shall be applied. The duration of the test shall not be less than 1 minute for each amplitude and polarity. For the coupling of the bursts into the input/ output and communication lines, a capacitive coupling clamp as defined in the standard shall be used. The test pulses shall be continuously applied during the measuring time. Test voltage Amplitude (peak value) 1 kV Repetition rate 5 kHz Table 11. (4) Surges on signal, data and control lines: disturbance test,- Object of the test Verification of compliance during conditions where electrical surges are superimposed on input/ output and communication ports. (1) (2) Test procedure in brief A surge generator shall be used. The characteristics of the generator shall be verified before connecting the equipment under test. The test comprises exposure to surges for which the rise time, pulse width, peak values of the output voltage/current on high/low impedance load and minimum time interval between two successive pulses as specified here. At least 3 positive and 3 negative surges shall be applied. The applicable injection network depends on the kind of wiring the surge is coupled into as specified here. The test pulses shall be continuously applied during the measuring time. Test voltage Unsymmetrical lines Line to line: 0.5 kV Line to ground: 1.0 kV Symmetrical lines Line to line: NA Line to ground: 1.0 kV Shielded input/ output and Line to line: NA Line to ground: 0.5 kV communication lines 7. Performance tests (electrical, mains power),-[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 113 Table 12. (1) DC mains voltage variation: influence test,- Object of the test Verification of compliance during conditions of DC mains network changes between upper and lower limit. (1) (2) Test procedure in brief The test comprises exposure to the specified power supply condition for a period sufficient for achieving temperature stability and subsequently performing the required measurements. Test severity The upper limit is the DC level at which the equipment under test is claimed and proven to have been manufactured to automatically detect high-level conditions. The lower limit is the DC level at which the equipment under test is claimed and proven to have been manufactured to automatically detect low-level conditions. The instrument shall comply with the specified maximum permissible error at supply voltage levels between the two levels Table 13. (2) AC mains voltage variation: influence test,- Object of the test Verification of compliance during conditions of AC mains network voltage changes between upper and lower limit. (1) (2) Test procedure in brief The test comprises exposure to the specified power condition for a period sufficient for achieving temperature stability and for performing the required measurements. Mains voltage (1), (2) upper limit U + 10 % nom lower limit U – 15 % nom Notes (1) In the case of three-phase power supply, the voltage variation shall apply for each phase successively. (2) The values of U are those marked on the measuring instrument. In case a range is specified, the “-” relates to the lowest value and the “+” to the highest value of the range. Table 14. (3) AC mains voltage dips and short interruptions: disturbance test,- Object of the test Verification of compliance during conditions of short time mains voltage reductions. (1) (2) Test procedure in brief A test generator is to be used which is suitable to reduce the amplitude of the AC mains voltage for the required period of time. The performance of the test generator shall be verified before connecting the equipment under test. The mains voltage reduction tests shall be repeated 10 times with intervals of at least 10 seconds between the tests. The test pulses shall be continuously applied during the measuring time. Test (1, 2) test a test b test c test d test e unit Voltage reduction Reduction 0 0 40 70 80 % to Duration 0.5 1 10/12(1) 25/30 (2) 250/300(1) cycles Notes (1) These values are for 50 Hz / 60 Hz, respectively. (2) All 5 tests (a, b, c, d and e) shall be complied; it is possible that any of the tests fail while the other tests pass. Table 15. (4) Voltage dips, short interruptions and voltage variations on DC mains power disturbance test,- Object of the test Verification of compliance during conditions of DC mains voltage dips,114 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] variations and short time reductions. (1) (2) Test procedure in brief A test generator shall be used. Before starting the tests, the performance characteristics of the generator shall be verified. The equipment under test shall be exposed to voltage dips and short interruptions for each of the selected combinations of amplitude and duration, using a sequence of three dips/interruptions and intervals of at least 10 seconds between each test event. The most common operating modes of the equipment under test shall be tested three times at 10 second intervals for each of the specified voltage variations. If the equipment under test is an integrating instrument, the test pulses shall be continuously applied during the measuring time. Test severity level The following levels shall be Unit applied: Voltage Amplitude 40 and 70 % of the rated voltage dips Duration(1) 10; 30; 100 ms Short Test High impedance and/or low interruptions condition impedance (4) Amplitude 0 % of the rated voltage Duration(1) 1; 3; 10 ms Voltage Amplitude 85 and 120 % of the rated voltage variations Duration(1) 0.1; 0.3; 1; 3; 10 s Notes (1)All intervals are to be tested Table 16. (5) Bursts (transients) on AC and DC mains: disturbance test,- Object of the test Verification of compliance during conditions where electrical bursts are superimposed on the mains voltage. (1) (2) Test procedure in brief A burst generator shall be used. The characteristics of the generator shall be verified before connecting the equipment under test. The test comprises exposure to bursts of voltage spikes for which the repetition frequency of the impulses and peak values of the output voltage on 50 Ω and 1 000 Ω loads. Both positive and negative polarity of the bursts shall be applied. The duration of the test shall not be less than 1 minute for each amplitude and polarity. The injection network on the mains shall contain blocking filters to prevent the burst energy from being dissipated in the mains. The test pulses shall be continuously applied during the measuring time. Amplitude (peak value) 2 kV Repetition rate 5 kHz Table 17. (6) Surges on AC and DC mains: disturbance test,- Object of the test Verification of compliance during conditions where electrical surges are superimposed on the mains voltage. (1) (2) Test procedure in brief A surge generator shall be used. The characteristics of the generator shall be verified before connecting the[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 115 equipment under test. The test comprises exposure to electrical surges for which the rise time, pulse width, peak values of the output voltage/current on high/low impedance load and the minimum time interval between two successive pulses. At least 3 positive and 3 negative surges shall be applied. On AC mains supply lines, surges shall be synchronous with the AC supply frequency and shall be repeated such that injection of surges on all the 4 phase shifts with 0°, 90°, 180° and 270° with the mains frequency is covered. The injection network circuitry depends on the applicable conductors the surge is coupled. The test pulses shall be continuously applied during the measuring time. Test voltage Line to line: 1.0 kV Line to ground: 2.0 kV Table 18. (7) Ripple on DC mains power,- Object of the test Verification of compliance during conditions where electrical surges are superimposed on the mains voltage. (1) (2) Test procedure in brief A test generator shall be used. Before starting the tests, the performance of the generator shall be verified. The test comprises subjecting the equipment under test to ripple voltages such as those generated by traditional rectifier systems or auxiliary service battery chargers overlaying on DC power supply sources. The frequency of the ripple voltage is the applicable power frequency or its multiple (2, 3 or 6), dependent on the rectifier system used for the mains. The waveform of the ripple, at the output of the test generator, has a sinusoid linear character. The test shall be applied for at least 10 minute or for the time period necessary to allow a complete verification of the equipment under test’s operating performance. Percentage of the 2 nominal DC voltage (1) Notes (1) The test levels are a peak-to-peak voltage expressed as a percentage of the nominal DC voltage. (2) This test does not apply to instruments connected to battery charger systems incorporating switch mode converters. 8. Performance test (battery powered instrument),- Table 19. A.8 Low voltage of internal battery (not connected to the mains power): influence test,- Object of the test Verification of compliance during low battery voltage conditions. (1) (2) Test procedure in brief The test comprises exposure of the equipment under test to the specific low battery level condition during a period sufficient for achieving temperature stability and for performing the required measurements. The maximum internal impedance of the battery and the minimum battery supply voltage level (U ) bmin are to be specified by the manufacturer of the instrument. In case of simulating the battery by using an alternative power supply source such as in bench testing, the internal impedance of the specified type of battery shall also be simulated. The alternative power supply shall be capable of delivering sufficient current at116 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] the applicable supply voltage. The test sequence is as follows,- Let the power supply stabilise at a voltage as defined within the rated operating conditions and apply the measurement or loading condition. Record,- (a) the data defining the actual measurement conditions including date, time and environmental conditions, (b) the actual power supply voltage. Perform measurements and record the errors and other relevant performance parameters. (I) Verify compliance with the requirements (II) Repeat the above procedure with actual supply voltage at U and again at bmin 0.9 U bmin . (III) Verify compliance with the requirements. The maximum internal impedance of the battery is to be specified by the manufacturer of the instrument. Lower limit of the The lowest voltage at which the instrument functions properly according to the voltage specifications. Number of cycles At least one test cycle for each functional mode. Annexure B: Flow disturbance tests (Mandatory) 1. General,- (1) The test specified in this Annexure shall be carried out with air at atmospheric pressure, at flow rates of 0.25 Q , 0.4 Q and Q . Alternatively, the test shall be performed with a suitable gas at a pressure within the max max max pressure range of the gas meter. (2) If the design of the type of the gas meter is similar for all pipe sizes, it is sufficient to perform the full set of tests on the one size which is considered as worst case situation for the meter family. Tests are also to be performed on other sizes if considered necessary. 2. Mild flow disturbances,- (1) Flow disturbance tests shall be executed using each of the applicable piping configurations as specified in Table B.1, mounted upstream of the meter, whereby the meter is installed according to the manufacturer's mounting specifications. (2) The test conditions e, f and g in Table B.1 do not apply to gas meters that are intended to be used in residential areas. All other test conditions in Table B.1 apply regardless of the environment (both residential and non- residential). (3) During each of the tests mentioned in sub-paragraph (1) of paragraph 2 of annexure B, the shift of the error curve of the gas meter shall comply with the requirement as specified in clause (iii) of sub-paragraph (13) of paragraph 4. A flow conditioner according to the manufacturer's specifications may be used to meet the requirements. In such a case the flow conditioner shall be specified in the model approval certificate. (4) If a specific minimum length of straight upstream piping L is necessary to meet the requirement as specified min in sub-paragraph (3) of paragraph 2 of annexure B, this L shall be applied during the tests and its value shall be min specified in the model approval certificate. (5) For ultrasonic gas meters the requirements as specified in clause (iii) of sub-paragraph (13) of paragraph 4 shall be met as well when adding an extra 10 D straight pipe length to the minimum length of straight upstream piping L for each test as specified in sub-paragraph (1) of paragraph 2 of annexure B. min[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 117 3. Severe flow disturbances,- (1) For severe disturbance tests the piping configurations (c) and (d) as specified in Table B.1 shall be used with an addition of a half pipe area plate, shown as + in Table B.1 installed upstream after the first bend of the applicable test piping configuration and with the half-moon opening toward the outside radius of this first bend. (2) The provisions of sub-paragraph (2), (3), (4) and (5) of paragraph 2 of Annexure B apply accordingly. Table B.1. Piping configurations for flow disturbance Test c ssa m Piping configurations Test conditions Remarks e n ib ru T in o sa rtlU la m re h T x e tro V (1) (2) (3) (4) (5) (6) (7) (8) approx. 80 D × × × straight line Reference (a) conditions approx. 10 D straight line × (see Note) (b) A single 90° bend radius elbow: 1.5 D × × × × Double out-of- rotating right; (c) × × × × plane bend radius elbows: 1.5 D Double out-of- rotating left; (d) × × × × plane bend radius elbows:1.5 D one step difference (e) Expander of the pipe diameter × × × is applied angle of (f) Reducer expansion/reduction × × × part: ≤ 15° Diameter step on approx. +3 % (g) the upstream × × × and –3 % flange image shows first Half pipe area bend in piping and + × × plate mounting of half- moon plate.118 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] Note: Any turbine meter will need to be equipped with a flow director (straightener and nose cone) in the upstream part. For this reason the influence of extending the upstream part with a straight line beyond the 10 D value will be negligible. Annexure C: Overview of requirements and applicable tests for different metering principles (Mandatory) 1. General,- This Annexure specifies the requirements and applicable tests required for a number of different metering principles. Requirements apply to all metering principles. The necessity of performing the related tests depends on the sensitivity of such physical metering principle to the phenomenon as specified in the requirement. Omission of a test shall only be done if there is an independent, internationally accepted and published evidence of insensitivity of the metering principle to the phenomenon. For those metering principles not listed in the table, the applicability of each test shall be determined. In Table C.1 the diaphragm gas meter, the Temperature Compensated (TC) diaphragm gas meter, the rotary piston gas meter and the turbine gas meter are considered as mechanical meters. If electronics, software or ancillary devices or a combination of both are added to these mechanical meters, the tests on electronics, software or ancillary devices shall also apply. Table C.1. Overview of requirements and applicable evaluation tests for the different metering principles Evaluation Requirement Test T opic c lause c lause m g a r h p a iD n o tsip y ra to R e n ib r u T c in o s a r tlU s ilo ir o C ssam lam reh T x e tr o V (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Sub paragraph (3) of Design inspection Paragraph 5 paragraph 11 × × × × × × × Error Sub- Clause (i) of × × × × × × × paragraph (3) sub-paragraph of paragraph (6) of and sub- paragraph 11 paragraph (4) of paragraph 11 sub- Clause (ii) of paragraph (6) sub-paragraph of paragraph (6) of Reproducibility 4 paragraph 11 × × × × × × × sub- Clause (iii) of paragraph (7) sub-paragraph of paragraph (6) of Repeatability 4 paragraph 11 × × × × × × × Clause (i) of sub- Clause (iv) of paragraph sub-paragraph (13) of (6) of Orientation paragraph 4 paragraph 11 - × × - × - -[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 119 Clause (ii) of sub- Clause (v) of paragraph sub-paragraph (13) of (6) of Flow direction paragraph 4 paragraph 11 - × × × × - - sub- Clause (vi) of paragraph (8) sub-paragraph of paragraph (6) of Working pressure 4 paragraph 11 - × × × × × × sub- Clause (vii) of paragraph (9) sub-paragraph of paragraph (6) of Temperature 4 paragraph 11 × × × × × × × Clause (iii) Clause (viii) of sub- of sub- paragraph paragraph (6) (13) of of paragraph Flow disturbance paragraph 4 11 - - × × - × × sub- Clause (ix) of if paragraph sub-paragraph if applicable (10) of (6) of applicable Durability paragraph 4 paragraph 11 × × × - - Clause (iv) if if Drive shaft test of sub- Clause (x) of applicable applicable paragraph sub-paragraph (13) of (6) of paragraph 4 paragraph 11 - - - - - (torque) sub- Clause (xi) of paragraph sub-paragraph (11) of (6) of Overload flow test paragraph 4 paragraph 11 × × × - - - - Different gases Clause (v) of sub- Clause (xi) of paragraph sub-paragraph (13) of (6) of paragraph 4 paragraph 11 × × × × × × × (if applicable) Vibrations and Clause (xiii) sub- of sub- paragraph paragraph (6) (12) of of paragraph paragraph 4 11 × × × × × × × shocks Clause (vi) if if if Interchangeable of sub- Clause (xiv) of applicable applicable applicable paragraph sub-paragraph (13) of (6) of paragraph 4 paragraph 11 - - - - components Clause (vii) 0 + of sub- paragraph (13) of Electronics paragraph 4 - - - × × × × Annexure A Influences from Clause (viii) Clause (xvi) of - - - × × × ×120 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] of sub- sub-paragraph paragraph (6) of (13) of paragraph 11 paragraph 4 ancillary devices Annexure D: Model approval of a family of gas meters (Mandatory) 1. Families of gas meters,- This Annexure specifies the criteria to be applied by the Director (Legal Metrology) in deciding whether a group of gas meters can be considered to be from the same family for model approval purposes, for which only selected samples of meter sizes are to be tested. 2. Definition,- A family of meters is a group of gas meters of different sizes or different flow rates, in which all the meters shall have the following characteristics, namely :- (a) the same manufacturer; (b) geometric similarity of the parts in contact with the gas; (c) the same metering principle; (d) the same accuracy class; (e) the same temperature range; (f) the same electronic device for each meter size; (g) a similar standard of design and component assembly; (h) the same materials for those components that are critical to the performance of the meter; (i) the same installation requirements relative to the meter size, e.g. 10 D (pipe diameter) of straight pipe upstream of the meter and 5 D of straight pipe downstream of the meter. 3. Meter selection,- For testing the size of a family of gas meters, the following rules shall be followed, namely:- (a) the Director (Legal Metrology) shall specify the reasons for including and omitting particular meter sizes from testing; (b) the smallest meter in any family of meters shall always be tested; (c) the meters which have the most extreme operating parameters within a family shall be considered for testing, e.g. the largest flow rate range, the highest peripheral speed of moving parts, and the like; (d) if practical, the largest meter in any family of meters shall be tested. Incase, the largest meter is not tested, then any meter having a Qmax> 2 × Qmax of the largest meter tested shall not be considered part of the family concerned; (e) the durability tests shall be applied to meters where the highest wear is expected; (f) for meters with no moving parts in the measurement transducer, the smallest size shall be selected for durability tests; (g) all performance tests relating to influence quantities shall be carried out on one size from a family of meters;[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 121 (h) the family members underlined in Figure D.1 may be considered as an example for testing (Note: Each row represents one family, meter 1 being the smallest). 1 1 2 1 2 3 1 2 3 4 1 2 3 4 5 1 2 3 4 5 6 Figure D.1: Family of meters pyramid Annexure E: Description of selected validation methods 1. Analysis of documentation and specification and validation of the design (AD),- (1) Application,- Basic procedure, applicable during all software validation assessments. (2) Preconditions for analysis of documentation and specification and validation of the design,- The procedure is based on the manufacturer’s documentation of the measuring instrument. The documentation shall include the following, namely:- (i) specification of the externally accessible functions of the instrument in a general form (suitable for simple instruments with no interfaces except a display, all features verifiable by functional testing, low risk of fraud); (ii) specification of software functions and interfaces necessary for instruments with interfaces and for instrument functions that cannot be functionally tested and in case of increased risk of fraud. The description shall make evident and explain all software functions that may have an impact on metrological features; (iii) concerning interfaces, the documentation shall include a complete list of commands or signals that the software is able to interpret and the effect of each command in detail. The way in which the instrument reacts on undocumented commands shall be described; (iv) additional documentation of the software for complex measuring algorithms, cryptographic functions, or crucial timing constraints shall be provided, if necessary for understanding and evaluating the software functions; (v) when the procedure to validate a function of a software program is not clear the onus to develop a test method shall be placed on the manufacturer. In addition, the services of the programmer shall be made available to the examiner for the purposes of answering questions.122 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] A general precondition for examination is the completeness of the documentation and the clear identification of the equipment under test, i.e. of the software packages that contribute to the metrological functions. (3) Description,- The testing laboratory evaluates the functions and features of the measuring instrument using the description in text and graphical representations and takes a decision regarding compliance of the requirements. Metrological requirements as well as software-functional requirements (e.g. fraud protection, protection of adjustment parameters, disallowed functions, communication with other devices, update of software, fault detection, etc.) have to be considered and evaluated. (4) Result,- The procedure gives a result for all characteristics of the measuring instrument, provided that the appropriate documentation has been submitted by the manufacturer. The result shall be documented in a section related to software in a Software Evaluation Report. (5) Complementary procedures,- Additional procedures shall be applied, if on examination the documentation cannot provide substantiated validation results. In most cases “Validating the metrological functions by functional testing” (as specified in paragraph 2 of annexure E) is a complementary procedure. 2. Validation by functional testing of the metrological functions (VFTM),- (1) Application,- To validate the correctness of algorithms for calculating the measurement value from raw data, for linearisation of a characteristic, compensation of environmental influences, rounding in price calculation, etc. (2) Preconditions,- The operating manual, functioning pattern, metrological references and test equipment are essential. (3) Description,- Most of the evaluation and test methods are based on reference measurements under various conditions. Their application is not restricted to a certain technology of the instrument. Although not aimed primarily at validating the software, the test results can be interpreted as a validation of some parts of the software, in general those that are metrologically the most important ones. If the tests cover all the metrologically relevant features of the instrument, the corresponding software parts can be regarded as being validated. In general, no additional software analysis or test has to be applied to validate the metrological features of the measuring instrument. (4) Result,- The correctness of algorithms is valid or invalid. Measurement values under all conditions are within the maximum permissible error or not. (5) Complementary procedures,- The method is normally an enhancement as specified in paragraph 1 of Annexure E. In certain cases it may be easier or more effective to combine the method with examinations based on the source code (as specified in paragraph 5 of Annexure E) or by simulating input signals (as specified in paragraph 6 of Annexure E) e.g. for dynamic measurements. 3. Validation by functional testing of the software functions (VFTSw),- (1) Application,- For validation of e.g. protection of parameters, indication of a software identification, software supported fault detection, configuration of the system (especially of the software environment), etc. (2) Preconditions,- The operating manual, functioning pattern, metrological references and test equipment are essential. (3) Description,-[भाग II—खण् ड 3(i)] भारत का रािपत्र : असाधारण 123 Required features described in the operating manual, instrument documentation or software documentation is checked in practice. If software controlled and functioning correctly, they are to be regarded as validated without any further software analysis. (4) Result,- To check software controlled feature under consideration is correct or not correct. (5) Complementary procedures,- Some features or functions of a software controlled instrument as described cannot be practically validated. If the instrument has interfaces, it is in general not possible to detect unauthorised commands only by trying commands at random. A sender is also needed to generate these commands. For the normal validation level method as specified in paragraph 1 of Annexure E, including a declaration by the manufacturer, may cover this requirement. For the extended examination level, a software analysis such as specified in paragraph 4 of Annexure E or paragraph 5 thereof is necessary. 4. Metrological dataflow analysis (DFA),- (1) Application,- For analysis of the software design concerning the control of the data flow of measurement values through the data domains that are subject to control, including the examination of the software separation. (2) Preconditions,- The software documentation, source code, editor, text search program or special tools are required. Knowledge of programming languages. (3) Description,- The aim of this analysis is to find all parts of the software that are involved in the calculation of the measurement values or that may have an impact on it. (4) Result,- It can be validated whether software separation as specified in paragraph 1 of Annexure E is correct or not correct. (5) Complementary procedures,- This method shall be used if software separation is realised and if high conformity or strong protection against manipulation is necessitated. 5. Code inspection and walk through (CIWT),- (1) Application,- Any feature of the software may be validated with this method if enhanced examination intensity is considered necessary. (2) Preconditions for Code inspection and walk through,- The source code, text editor, tools and knowledge of programming languages is necessary. (3) Description,- The testing laboratory walks through the source code assignment by assignment, evaluating the respective part of the code to determine whether the requirements are fulfilled and whether the program functions and features are in compliance with the documentation. The testing laboratory may also concentrate on algorithms or functions that have been identified as complex, error- prone, insufficiently documented, etc. and inspect the respective part of the source code by analysing and checking. (4) Result,- To check if implementation is compatible with the software documentation and in compliance with the requirements.124 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (5) Complementary procedures,- This is an enhanced method, additional to paragraph 1 of Annexure E and paragraph 4 of the said Annexure. Normally it is only applied in spot checks. 6. Software module testing (SMT),- (1) Application,- Only if a high level of security and protection against fraud is required. This method is to be applied when routines of a program cannot be examined exclusively on the basis of written information and is appropriate and economically advantageous in validating dynamic measurement algorithms. (2) Preconditions,- Source code, development tools (at least a compiler), functioning environment of the software module under test, input data set and corresponding correct reference output data set or tools for automation with skills in information technology, knowledge of programming languages and co-operation with the programmer of the module under test is required. (3) Description,- The software module under test is integrated in a test environment, i.e. a specific test program module that calls the module under test and provides it with all necessary input data. The test program compares the output data from the module under test with the expected reference values. (4) Result,- To check if measuring algorithm or other tested functions are correct or not. (5) Complementary procedures,- This is an enhanced method, additional to paragraph 2 of Annexure E or paragraph 5 of the said Annexure. [F. No. WM-9(39)/2015] ANUPAM MISHRA, Jt. Secy. Note:- The principal rules were published in the Gazette of India, Extraordinary, Part II, Section 3, Sub-section (i), vide notification number G.S.R.71(E), dated the 7th February, 2011 and was last amended, vide notification number G.S.R. 34(E), dated the 14th January, 2025. Uploaded by Dte. of Printing at Government of India Press, Ring Road, Mayapuri, New Delhi-110064 and Published by the Controller of Publications, Delhi-110054.

Continue your research