Home India Ministry of Power Implementation under Tariff Based Competitive Bidding (TBCB)...
Date: 2025-03-19 Category: Extra Ordinary State: Union Government Country: India

Implementation under Tariff Based Competitive Bidding (TBCB)

Issued by Ministry of Power · Not Applicable

Research with AI Agent Chat with Document Generate Summary Translate Helpful Share Add to Project Create Task

Executive Summary & Key Takeaways

Gazette Notification Overview

  • The gazette notification addresses modifications and notifications related to transmission schemes for renewable energy evacuation in Madhya Pradesh and Gujarat.
  • It includes de-notification of certain previously notified schemes, notification of a new transmission scheme under Tariff Based Competitive Bidding (TBCB) mode, and modifications to the scope of an existing transmission scheme.

Key Changes - Madhya Pradesh

  • De-notification of transmission schemes for evacuation of power from RE projects in Rajgarh (1500 MW) SEZ and Neemuch (1000 MW) SEZ, previously notified via Gazette Notification S.O. 5376(E) dated 12.12.2024.
  • Notification of a new transmission scheme under TBCB mode for evacuation of power from RE projects in Rajgarh (1500 MW) and Neemuch (1000 MW) SEZs. The Bid Process Coordinator (BPC) is REC Power Development and Consultancy Limited.
  • The Rajgarh element has a tentative implementation timeframe of 31.03.2028 for Purvah Green Power Pvt. Ltd. (297 MW) interconnection, and 24 months from SPV transfer date for remaining elements.
  • The scheme includes creation of a new 220 kV Bus Section, installation of ICTs, line bays, reactors, and associated infrastructure at Pachora PS and Neemuch PS.
  • MPPTCL will implement specific works related to LILO of 220 kV lines at Handiya 400 (New ISTS S/s) in coordination with the Handiya (ISTS) S/s timeframe.

Key Changes - Gujarat

  • Modification of the scope of the transmission system for evacuation of RE power from the Raghanesda area of Gujarat (3 GW) under Phase-I, initially notified via Gazette Notification S.O. 3545(E) dated 21.08.2024.
  • PFC Consulting Limited is the BPC.
  • The implementation timeframe is 27 months for Sl. 1 to 3, 30.09.2027 (minimum 27 months) for Sl. 4 & 5, and 31.03.2028 for Sl. 6.
  • The scheme includes establishment of a 765/400 kV substation near Raghanesda (GIS), a 765 kV D/c line to Banaskantha (PG), and associated infrastructure.
  • It also includes the creation of a 220 kV switchyard at Raghanesda PS (GIS) and line bays for the interconnection of solar projects of Azure Power Sixty Three Pvt. Ltd. (300 MW) and Sunsure Solarpark RJ One Pvt. Ltd. (350 MW).

Impact Analysis

Renewable Energy Developers

  • Action Item: Coordinate with the BPC (REC Power Development and Consultancy Limited and PFC Consulting Limited) and concerned transmission service providers to align project timelines with the transmission infrastructure development.

Transmission Service Providers (TSPs)

  • Action Item: Develop detailed project plans, secure necessary approvals, and ensure timely execution of the transmission projects.

State Transmission Utilities (STUs)

  • Action Item: MPPTCL needs to align its project timelines with the Handiya (ISTS) S/s development and coordinate with the relevant stakeholders.

Consumers

  • Action Item: Monitor the progress of the transmission projects and advocate for policies that promote the integration of renewable energy into the grid.

BPC (REC Power Development and Consultancy Limited and PFC Consulting Limited)

  • Action Item: Ensure a transparent and competitive bidding process to select qualified developers for the transmission projects.

Key Entities Referenced

Ministry of Power: The central government ministry responsible for formulating policies and regulations related to the power sector. National Committee on Transmission (NCT): A committee that provides recommendations on transmission schemes to the central government. REC Power Development and Consultancy Limited: The Bid Process Coordinator (BPC) for the Madhya Pradesh transmission scheme. PFC Consulting Limited: The Bid Process Coordinator (BPC) for the Gujarat transmission scheme. MPPTCL: Madhya Pradesh Power Transmission Company Limited, the State Transmission Utility (STU) in Madhya Pradesh. RUMSL: Renewable Energy Management Centre POWERGRID: Power Grid Corporation of India Limited, a major transmission service provider. M/s GR Infra Projects: Transmission service provider for Pachora PS. Purvah Green Power Pvt. Ltd.: A renewable energy generator with a 297 MW project in Madhya Pradesh. Azure Power Sixty Three Pvt. Ltd.: A solar power project developer with a 300 MW project in Gujarat. Sunsure Solarpark RJ One Pvt. Ltd.: A solar power project developer with a 350 MW project in Gujarat. Electricity Act, 2003: The primary legislation governing the electricity sector in India.
Official Source Record View Original Source →
See Full Document Text
रजिस्ट्री स.ं डी.एल.- 33004/99 REGD. No. D. L.-33004/99 सी.जी.-डी.एल.-अ.-21032025-261810 CG-DxLx-xEG-I2D1H0x3x2x0 25-261810 xxxGIDExxx असाधारण EXTRAORDINARY भाग II—खण् ड 3—उप-खण्ड (ii) PART II—Section 3—Sub-section (ii) प्राजधकार स ेप्रकाजित PUBLISHED BY AUTHORITY स.ं 1308] नई दिल्ली, बुधिार, माच च19, 2025/फाल्ग नु 28, 1946 No. 1308] NEW DELHI, WEDNESDAY, MARCH 19, 2025/PHALGUNA 28, 1946 जिद्यतु मत्रं ालय अजधसचू ना नई दिल्ली, 18 माच,च 2025 का.आ. 1325(अ).—नीचे उजल्लजखत रािपत्र अजधसूचना के माध्यम से टैररफ आधाररत प्रजतस्ट्पधी बोली (टीबीसीबी) के अंतगतच कायाचन्ियन के जलए जनम्नजलजखत पारेषण स्ट्कीमों को अजधसूजचत दकया गया था :— क्रम स.ं स्ट्कीम का नाम रािपत्र अजधसचू ना जिसके द्वारा स्ट्कीम अजधसजू चत की गई 1. मध्य प्रिेि में रािगढ़ (1500 मेगािाट) एसईज़ेड म ें का.आ. 5376(अ) दिनांक 12.12.2024 [फा. निीकरणीय ऊिाच पररयोिनाओं से जिद्युत जनकासी के स.ं 15/3/2018-रांस-भाग(4)] जलए पारेषण प्रणाली- चरण III 2. मध्य प्रिेि में नीमच (1000 मेगािाट) एसईिेड म ें का.आ. 5376(अ) दिनांक 12.12.2024 [फा. निीकरणीय ऊिा च पररयोिनाओं से जिद्युत की जनकासी स.ं 15/3/2018-रांस-भाग(4)] के जलए पारेषण प्रणाली- चरण II 1894 GI/2025 (1)2 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(ii)] 2. दिनांक 06.01.2025 को आयोजित राष्ट्रीय पारेषण सजमजत (एनसीटी) की 26िीं बैठक में उपयुचक्त स्ट्कीमों की अजधसूचना रद्द करने की जसफाररि की गई थी। इस प्रकार, उपयुचक्त स्ट्कीम,ें उनके कायचक्षेत्र सजित, एतद्द्वारा गैर-अजधसूजचत की िाती ि।ै 3. इसके अजतररक्त, जिद्युत अजधजनयम, 2003 (2003 का 36) की धारा 63 के अंतगचत पररचाजलत दििाजनिेिों के परै ा 3 के उप-परै ा 3.2 द्वारा प्रित्त िजक्तयों का प्रयोग करत े हुए, केंद्र सरकार, राष्ट्रीय पारेषण सजमजत की 26िीं बैठक की जसफाररिों पर, संबंजधत बोली-प्रदक्रया समन्ियक (बीपीसी) के जििरण के साथ टीबीसीबी मोड के तित जनम्नजलजखत पारेषण स्ट्कीम को अजधसूजचत करती ि:ै— क्रम पारेषण स्ट्कीम का नाम और कायक्षच त्रे स.ं 1. मध्य प्रिेि म ें रािगढ़ (1500 मगे ािाट) एसईिडे म ें निीकरणीय ऊिा च पररयोिनाओं स े जिद्यतु जनकासी के जलए पारेषण प्रणाली- चरण III और मध्य प्रिेि म ें नीमच (1000 मगे ािाट) एसईिडे म ें निीकरणीय ऊिा च पररयोिनाओं स ेजिद्यतु जनकासी के जलए पारेषण प्रणाली- चरण II कायान्च ियन की सभं ाजित समय-सीमा: क्रम स.ं 2ख म ें एलीमटें के कायाचन्ियन की समय-सीमा आरई उत्पािक (पूिा च ग्रीन पािर प्राइिेट जलजमटेड: 297 मेगािाट) की समय-सीमा के अनुरूप दिनांक 31.03.2028 िोगी और िषे एलीमेंट के जलए यि एसपीिी अंतरण की तारीख से 24 मिीन े िोगी। बीपीसी: आरईसी पािर डेिलपमटें एंड कंसल्टेंसी जलजमटेड कायक्षच त्रे : क्रम स.ं पारेषण स्ट्कीम का कायक्षच त्रे क्षमता 1. 220 केिी बस सेक्िनलाइज़र के साथ नए • 500 एमिीए 400/220 केिी आईसीटी – 3 220 केिी बस सेक्िन (तृतीय) का जनमाचण, • 400 केिी आईसीटी बे – 3 (सक्े िन-II पर) और 220 केिी बस सेक्िन (तृतीय) पर • 220 केिी आईसीटी बे – 3 (सक्े िन-III पर) समाप्त पचोरा पीएस पर 400/220 केिी, • 220 केिी बस सेक्िनलाइिर बे – 1 सेट 3x500 एमिीए आईसीटी संिधचन (7िां, 8िा ं और 9िां) • 220 केिी बीसी और टीबीसी – 1 प्रत्येक 2. 2क. बस सेक्िन (ततृ ीय) पर आरई • सेक्िन-III पर 3 इंटरकनेक्िन के जलए 3 220 केिी लाइन ब े 3. 2ख. बस सेक्िन (तीसरा) पर पूिाच ग्रीन • सेक्िन-III पर 1 पािर प्राइिेट जलजमटेड के आरई इंटरकनेक्िन के जलए 1 220 केिी लाइन ब े 4. िोनों जसरों पर संबद्ध लाइन बे के साथ पचोरा • लाइन की लंबाई: 180 दकमी. पीएस – रािगढ़ (पीिी) 400 केिी डी/सी • 400 केिी लाइन बे: 4 (2 रािगढ़ (पीिी) पर लाइन (क्वाड एसीएसआर/ एएएसी/एएल 59 और 2 पचोरा पीएस पर) मूस समतुल्य) और िोनों जसरों पर प्रत्येक • 420 केिी, जस्ट्िचेबल लाइन ररएक्टर सर्कचट पर 50 एमिीएआर जस्ट्िचेबल लाइन (एसडब्लल्यूएलआर): 4 (2 रािगढ़ (पीिी) पर ररएक्टर (एसडब्लल्यूएलआर) और 2 पचोरा पीएस पर) • 400 केिी लाइन ररएक्टर के जलए जस्ट्िचचंग उपकरण - 4 (2 रािगढ़ (पीिी) पर और 2 पचोरा पीएस पर) 5. पचोरा पीएस (400 केिी बस सेक्िन- II) म ें • 125 एमिीएआर, 420 केिी बस ररएक्टर-1[भाग II—खण् ड 3(ii)] भारत का रािपत्र : असाधारण 3 1x125 एमिीएआर, 420 केिी बस ररएक्टर • 400 केिी बस ररएक्टर बे:1 की संस्ट्थापना 6. संबद्ध बे के साथ-साथ नीमच एस/एस पर • 500 एमिीए 400/220 केिी आईसीटी – 3 3x500 एमिीए, 400/220 केिी आईसीटी • 400 केिी आईसीटी बे – 3 (तीसरा, चौथा और पांचिां) द्वारा पररितचन • 220 केिी आईसीटी बे – 3 (सक्े िन- II पर) क्षमता म ें संिधचन के साथ नीमच पीएस पर • 220 केिी बस सेक्िनलाइज़र बे – 1 सेट नए 220 केिी बस सेक्िन-II का जनमाचण। • 220 केिी बीसी और टीबीसी – 1 प्रत्येक 7. आरई इंटरकनेक्िन के जलए नीमच पीएस पर • 220 केिी बे – सेक्िन-II पर 4 4 220 केिी लाइन ें 8. संबद्ध लाइन बे के साथ नीमच पीएस – • लाइन की लंबाई: 190 दकमी. पचोरा पीएस 400 केिी डी/सी लाइन (क्वाड • 400 केिी लाइन बे: 4 (नीमच पीएस पर 2 एसीएसआर/एएएसी/एएल 59 मूस समतल्ु य) और पचोरा पीएस पर 2) और िोनों जसरों पर प्रत्येक सर्कचट पर 50 • 420 केिी, जस्ट्िचेबल लाइन ररएक्टर एमिीएआर जस्ट्िचेबल लाइन ररएक्टर (एसडब्लल्यू एलआर): 4 (नीमच पीएस पर 2 (एसडब्लल्यूएलआर) और पचोरा पीएस पर 2) • 400 केिी लाइन ररएक्टर के जलए जस्ट्िचचंग उपकरण – 4 (नीमच पीएस पर 2 और पचोरा पीएस पर 2) 9. 2x125 एमिीएआर 420 केिी बस ररएक्टर • 400/220 केिी आईसीटी: 2 के साथ-साथ िजं डया म ें 2x500 एमिीए, • 400 केिी आईसीटी बे: 2 400/220 केिी एस/एस की स्ट्थापना • 220 केिी आईसीटी बे: 2 • 400 केिी लाइन बे: 6 भािी प्रािधान (के जलए स्ट्थान): • एमपीपीटीसीएल के जलए 220 केिी लाइन बे – 8 ➢ जस्ट्िचेबल लाइन ररएक्टर के साथ 400 • 125 एमिीएआर, 420 केिी बस ररएक्टर – 2 केिी लाइन ब े - 6 (सेक्िन-II) • 400 केिी बस ररएक्टर बे: 2 ➢ बे के साथ 400/220 केिी आईसीटी - 4 • 220 केिी टीबीसी बे – 1 (सेक्िन-I पर 1 और सेक्िन-II पर 3) • 220 केिी बीसी बे – 1 ➢ बे के साथ 400 केिी बस ररएक्टर : 2 (सेक्िन-II) ➢ 220 केिी लाइन बे: 8 (सेक्िन-II पर) ➢ 400 केिी सेक्िनलाइिेिन बे: 1 सेट ➢ 220 केिी सेक्िनलाइिेिन बे: 1 सेट ➢ 220 केिी टीबीसी एिं बीसी: 1 10 पचोरा पीएस छोर पर संबद्ध बे के साथ • लाइन की लंबाई: 190 दकमी. पचोरा पीएस-िजं डया 400 केिी डी/सी • 400 केिी बे: 2 (पचोरा पीएस में) लाइन (क्वाड एसीएसआर/एएएसी/एएल59 • 420 केिी, एसडबल्यूएलआर : 4 (2 िजं डया म ें मूस समतुल्य) और िोनों छोर पर प्रत्येक और 2 पचोरा पीएस में) सर्कचट पर 50 एमिीएआर जस्ट्िचेबल लाइन • 400 केिी लाइन ररएक्टर के जलए जस्ट्िचचंग ररएक्टर (एसडब्लल्यू एलआर) उपकरण – 4 (2 िजं डया म ें और 2 पचोरा पीएस पर)4 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(ii)] 11 िजं डया एस/एस पर खडं िा (पीिी)- इटारसी • लीलो मागच की लंबाई: 22 दकमी (88 सीकेएम) (पीिी) 400 केिी डी/सी (जविन मूस) लाइन • खंडिा (पीिी) - इटारसी (पीिी) 400 केिी की लीलो डी/सी लाइन जविन मूस कॉजऩ्िगरेिन की ि ै और लीलो समान कंडक्टर कॉजऩ्िगरेिन की िोगी 12 नीमच पीएस में 1x125 एमिीएआर, 420 • 125 एमिीएआर, 420 केिी बस ररएक्टर – 1 केिी बस ररएक्टर (जद्वतीय) की संस्ट्थापना • 400 केिी बस ररएक्टर बे: 1 नोट: 1. नीमच पीएस का टीएसपी (मौिूिा) नीमच पीएस में उपयक्तुच कायच क्षेत्र के जलए (जनिःिल्ु क) स्ट्थान उपलब्लध कराएगा। 2. टीएसपी, पचोरा पीएस के भीतर उपलब्लध भूजम (जनिःिुल्क) के जलए मेससच िीआर इन्रा प्रोिेक्वस (पचोरा पीएस के टीएसपी) के साथ समन्िय करेगा तथा पचोरा पीएस म ें कायचक्षेत्र को जिकजसत करन े के जलए आिश्यकतानुसार अजतररक्त भूजम के अजधग्रिण के जलए आरयूएमएसएल के साथ समन्िय करेगा। 3. जिषयगत स्ट्कीम के अंतगचत पचोरा पीएस म ें 400 केिी लाइनें (पचोरा पीएस-रािगढ़, नीमच-पचोरा पीएस और पचोरा पीएस-िजं डया), 400/220 केिी, 3x500 एमिीए आईसीटी और 1x125 एमिीएआर, 420 केिी बस ररएक्टर को मेससच िी आर इंरा प्रोिेक्वस जलजमटेड द्वारा रािगढ़ चरण-II: 1000 मेगािाट स्ट्कीम के अंतगचत कायाचजन्ित दकए िा रि े पचोरा पीएस के 400 केिी स्ट्तर के बस सेक्िन-II पर समाप्त दकया िाएगा। 4. एमपीपीटीसीएल िजं डया (आईएसटीएस) एस/एस के अनरूु प समय-सीमा में कायों के नीचे दिए गए कायचक्षेत्र को लाग ू करेगा (िैसा दक एमपीपीटीसीएल द्वारा दिनांक 23.07.2024 के ई-मले द्वारा पुजि की गई ि)ै : क्रम स.ं काय चका नाम लाइन की लबं ाई (दकमी) 1. िजं डया 400 (नए आईएसटीएस एस/एस) पर िजं डया 2x10 दकमी (एमपीपीटीसीएल) 220 स े जबसोनीकला (टीबीसीबी) 220 केिी (लगभग) लाइनों के िोनों सर्कचटों की लीलो। 2. िजं डया 400 (नया आईएसटीएस एस/एस) पर इटारसी (एमपी) स े 10 दकमी (लगभग) िजं डया (एमपीपीटीसीएल) 220 केिी लाइन की लीलो। 3. िजं डया 400 (नया आईएसटीएस एस/एस) पर इटारसी (एमपी) स े 10 दकमी (लगभग) बरिािा (एमपी) 220 केिी लाइन की लीलो । 2. बोली प्रदक्रया समन्ियक की जनयुजक्त, जिद्युत मंत्रालय द्वारा इस संबंध में िारी और समय-समय पर संिोजधत दििाजनिेिों में जनधाचररत ितों के अध्याधीन िोगी। [फा.स.ं 15/3/2018-रांस-भाग(4)] नाओरेम इंद्रकुमार चसंि, अिर सजचि (पारेषण)[भाग II—खण् ड 3(ii)] भारत का रािपत्र : असाधारण 5 MINISTRY OF POWER NOTIFICATION New Delhi, the 18th March, 2025 S.O. 1325(E).— The following transmission schemes were notified for implementation under Tariff Based Competitive Bidding (TBCB) vide Gazette Notification mentioned below:— Sl. Name of the Scheme Gazette Notification by which Scheme was No. notified 1. Transmission system for Evacuation of Power from RE S.O. 5376(E) dated 12.12.2024 [F. No. Projects in Rajgarh (1500 MW) SEZ in Madhya 15/3/2018-Trans-Part(4)] Pradesh-Phase III 2. Transmission system for Evacuation of Power from RE S.O. 5376(E) dated 12.12.2024 [F. No. Projects in Neemuch (1000 MW) SEZ in Madhya 15/3/2018-Trans-Part(4)] Pradesh-Phase II 2. Above mentioned schemes were recommended for de-notification in 26th meeting of National Committee on Transmission (NCT), held on 06.01.2025. As such, above schemes, including their scopes are hereby de-notified. 3. Further, In exercise of the powers conferred by sub-para 3.2 of Para 3 of the Guidelines circulated under Section 63 of the Electricity Act, 2003 (No. 36 of 2003), the Central Government, on the recommendations of 26th meeting of National Committee on Transmission, hereby notifies the following transmission scheme under TBCB mode, with details of respective Bid-Process Coordinator (BPC):— Sl. N ame & Scope of the Transmission Scheme No. 1. Transmission system for Evacuation of Power from RE Projects in Rajgarh (1500 MW) SEZ in Madhya Pradesh-Phase III and Evacuation of Power from RE Projects in Neemuch (1000 MW) SEZ in Madhya Pradesh-Phase II Tentative implementation timeframe: Implementation timeframe of element at Sl. No. 2b shall be 31.03.2028 in matching timeframe of RE generator (Purvah Green Power Pvt. Ltd.: 297 MW) and for remaining elements it shall be 24 months from date of SPV transfer BPC: REC Power Development and Consultancy Limited Scope: Sl. Scope of the Transmission Scheme Capacity No. 1. Creation of New 220 kV Bus Section (3rd) • 500 MVA 400/220 kV ICT – 3 Nos. with 220 kV Bus Sectionaliser and 400/220 • 400 kV ICT bay – 3 Nos. (on Section-II) kV, 3x500 MVA ICT augmentation (7th, 8th & 9th) at Pachora PS terminated on 220 • 220 kV ICT bay – 3 Nos. (on Section-III) kV Bus Section (3rd) • 220 kV Bus Sectionaliser bays – 1 set • 220 kV BC & TBC – 1 No. each 2. 2a. 3 Nos. 220 kV line bays for RE • 3 Nos. on Sec-III interconnection on Bus Section (3rd) 3. 2b. 1 No. 220 kV line bay for RE • 1 No. on Sec-III Interconnection of Purvah Green Power Pvt. Ltd. on Bus Section (3rd) 4. Pachora PS – Rajgarh (PG) 400 kV D/c line • Line length: 180 km. (Quad ACSR/ AAAC/ AL59 Moose • 400 kV line bays: 4 Nos. (2 at Rajgarh (PG) equivalent) along with associated line bays at & 2 at Pachora PS) both ends and 50 MVAr Switchable Line Reactors (Sw LR) on each ckt at both ends • 420 kV, Switchable Line Reactors (Sw LRs): 4 Nos. (2 at Rajgarh (PG) & 2 at Pachora PS)6 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(ii)] • Switching equipment for 400 kV line reactor – 4 Nos. (2 at Rajgarh (PG) & 2 at Pachora PS) 5. Installation of 1x125 MVAr, 420 kV bus • 125 MVAr, 420 kV Bus reactor – 1 No. reactor at Pachora PS (400 kV Bus Section- • 400 kV Bus reactor bay: 1 No. II) 6. Creation of New 220 kV Bus Section-II at • 500 MVA 400/220 kV ICT – 3 Nos. Neemuch PS with Augmentation of • 400 kV ICT bay – 3 Nos. transformation capacity by 3x500 MVA, 400/220 kV ICTs (3rd, 4th & 5th) at Neemuch • 220 kV ICT bay – 3 Nos. (on Sec- II) S/s along with associated bays. • 220 kV Bus Sectionaliser bays – 1 set • 220 kV BC & TBC – 1 No. each 7. 4 Nos. 220 kV Line bays at Neemuch PS for • 220 kV Bays – 4 Nos. on Sec-II RE interconnection 8. Neemuch PS – Pachora PS 400 kV D/c line • Line length: 190 km. (Quad ACSR/ AAAC/ AL59 Moose • 400 kV Line bays: 4 Nos. (2 at Neemuch PS equivalent) along associated Line bays and 50 & 2 at Pachora PS) MVAr Switchable Line Reactor (Sw LR) on each ckt at both ends • 420 kV, Switchable Line Reactors (Sw LRs): 4 Nos. (2 at Neemuch PS & 2 at Pachora PS) • Switching equipment for 400 kV line reactor – 4 Nos. (2 at Neemuch PS & 2 at Pachora PS) 9. Establishment of 2x500 MVA, 400/220 kV • 400/220 kV ICTs: 2 Nos. S/s at Handiya alongwith 2x125 MVAr 420 • 400 kV ICT Bays: 2 Nos. kV Bus Reactors • 220 kV ICT Bays: 2 Nos. • 400 kV Line bays: 6 Nos. Future provision (space for): • 220 kV Line bays for MPPTCL – 8 Nos. ➢ 400 kV line bays along with switchable line reactors– 6 Nos. (Sec-II) • 125 MVAr, 420 kV Bus reactor – 2 Nos. ➢ 400/220 kV ICT along with bays - • 400 kV Bus reactor bay: 2 Nos. 4 Nos. (1 No. on Sec-I & 3 Nos. on Sec- • 220 kV TBC bay – 1 No. II) • 220 kV BC bay – 1 No. ➢ 400 kV Bus Reactor along with bays: 2 Nos. (Sec-II) ➢ 220 kV line bays: 8 Nos. (on Sec-II) ➢ 400 kV Sectionalization bay: 1 set ➢ 220 kV Sectionalization bay: 1 set ➢ 220 kV TBC & BC: 1 No. 10 Pachora PS – Handiya 400 kV D/c line • Line length: 190 km. (Quad ACSR/ AAAC/ AL59 Moose • 400 kV bays: 2 Nos. (at Pachora PS) equivalent) along with associated bays at Pachora PS end and 50 MVAr Switchable • 420 kV, Sw LRs: 4 Nos. (2 at Handiya & 2 Line Reactor (Sw LR) on each ckt at both at Pachora PS) ends • Switching equipment for 400 kV line reactor – 4 Nos. (2 at Handiya & 2 at Pachora PS) 11 LILO of Khandwa (PG) – Itarsi (PG) 400 • LILO route length : 22 km (88 ckm) kV D/c (Twin Moose) line at Handiya S/s • The Khandwa (PG) – Itarsi (PG) 400 kV D/c line is of Twin Moose configuration and LILO shall be of similar conductor configuration[भाग II—खण् ड 3(ii)] भारत का रािपत्र : असाधारण 7 12 Installation of 1x125 MVAR, 420 kV bus • 125 MVAr, 420 kV Bus reactor – 1 No. reactor (2nd) at Neemuch PS • 400 kV Bus reactor bay: 1 No. Note: 1. TSP (Existing) of Neemuch PS shall provide space for above scope of work (free of cost) at Neemuch PS. 2. The TSP shall coordinate with M/s GR Infra Projects (TSP of Pachora PS) for available land within Pachora PS (free of cost) and shall coordinate with RUMSL for acquisition of additional land as required for developing the scope of work at Pachora PS. 3. 400 kV lines (Pachora PS -Rajgarh, Neemuch - Pachora PS & Pachora PS – Handiya), 400/220 kV, 3x500 MVA ICTs & 1x125 MVAR, 420 kV bus reactor at Pachora PS under the subject scheme shall be terminated at bus section-II of 400 kV level of Pachora PS being implemented under Rajgarh Phase-II: 1000 MW scheme by M/s G R Infra projects Ltd. 4. MPPTCL to implement below scope of works in matching time-frame of Handiya (ISTS) S/s (as confirmed by MPPTCL vide e-mail dated 23.07.2024): Sl. Name of Work Line Length No. (Km) 1. LILO of both Circuit of Handia (MPPTCL) 220 to Bisonikala 2x10 km (TBCB) 220 kV lines at Handia 400 (New ISTS S/s). (Approx) 2. LILO of Itarsi (MP) to Handia (MPPTCL) 220 kV line at 10 km (Approx) Handia 400 (New ISTS S/s). 3. LILO of Itarsi (MP) to Barwaha (MP) 220 kV line at Handia 10 km (Approx) 400 (New ISTS S/s). 2. The appointment of the Bid Process Coordinator is subject to the conditions laid down in the Guidelines issued by Ministry of Power in this regard, amended from time to time. [F.No. 15/3/2018-Trans-Part(4)] NAOREM INDRAKUMAR SINGH, Under Secy. (Transmission) अजधसचू ना नई दिल्ली, 18 माच,च 2025 का.आ. 1326(अ).— जिद्युत अजधजनयम, 2003 (2003 की सं. 36) की धारा 63 के अंतगचत पररचाजलत दििाजनिेिों के परै ा 3 के उप-पैरा 3.2 द्वारा प्रित्त िजक्तयों का प्रयोग करत े हुए, केंद्र सरकार ने नीचे उजल्लजखत रािपत्र अजधसूचना के माध्यम से टीबीसीबी मोड के अंतगचत कायाचन्ियन के जलए जनम्नजलजखत स्ट्कीम को अजधसूजचत दकया था:— क्र.स.ं स्ट्कीम का नाम रािपत्र अजधसचू ना जिसके द्वारा स्ट्कीम अजधसजू चत की गई थी 1. गुिरात के राघनेस्ट्िा क्षेत्र से निीकरणीय ऊिाच की का. आ. 3545(अ) दिनांक 21.08.2024 [फा. जनकासी के जलए पारेषण प्रणाली- चरण-I के अंतगचत 3 सं. 15/3/2018- रांस -भाग(4)] गीगािाट 2. अब, केन्द्र सरकार न े 26िीं राष्ट्रीय पारेषण सजमजत की जसफाररिों पर टीबीसीबी मोड के अंतगचत उपयक्तुच पारेषण स्ट्कीम के काय-च क्षत्रे को जनम्नानुसार संिोजधत करन े का जनणचय जलया ि:ै — क्र.स.ं पारेषण स्ट्कीम का नाम और काय-च क्षत्रे 1. गिु रात के राघनस्ट्े िा क्षत्रे स े निीकरणीय ऊिा च की जनकासी के जलए पारेषण प्रणाली- चरण-I के अतं गतच 3 गीगािाट कायान्च ियन की सभं ाजित समय-सीमा: क्रम स.ं 1 स े 3: 27 मिीन,े क्रम स.ं 4 और 5: 30.09.2027 (न्यनू तम8 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(ii)] 27 माि के अधीन) और क्रम स ं6: 31.03.2028 बीपीसी: पीएफसी कंसचल्टंग जलजमटेड काय-च क्षत्रे : क्र. पारेषण स्ट्कीम का काय-च क्षत्रे क्षमता स. 1. 2x330 एमिीएआर, 765 केिी बस ररएक्टर • 765/400 केिी, 1500 एमिीए आईसीटी और 2x125 एमिीएआर, 420 केिी बस - 4 (अजतररक्त आईसीटी यूजनट सजित ररएक्टर के साथ राघनेस्ट्िा (िीआईएस) के 13x5000 एमिीए चसंगल फेि यूजनट) जनकट 4x1500 एमिीए, 765/400 केिी • 765 केिी आईसीटी बे – 4 सबस्ट्टेिन की स्ट्थापना • 400 केिी आईसीटी बे – 4 भजिष्य के जलए स्ट्थान प्रािधान: • 765 केिी लाइन बे – 2 ➢ बे के साथ 765/400 केिी आईसीटी - 4 • 1x330 एमिीएआर, 765 केिी बस (सेक्िन-II पर) ररएक्टर- 2 (7x110 एमिीएआर चसंगल ➢ जस्ट्िचेबल लाइन ररएक्टरके साथ 765 केिी फेि ररएक्टर जिसमें बस/लाइन ररएक्टर लाइन ब े - 8 (सेक्िन-I पर 4 और सेक्िन- के जलए एक अजतररक्त यूजनट िाजमल ि)ै II पर 4) • 765 केिी बस ररएक्टर बे – 2 ➢ बे के साथ 765 केिी बस ररएक्टर : 2 • 125 एमिीएआर, 420 केिी ररएक्टर- 2 (सेक्िन-II पर) • 400 केिी ररएक्टर बे- 2 ➢ 765 केिी सेक्िनलाइिर: 1-सटे • 400 केिी लाइन बे – 4 (आरई ➢ जस्ट्िचेबल लाइन ररएक्टर के साथ 400 पररयोिनाओं के इंटरकनेक्िन के जलए) केिी लाइन बे - 12 (सेक्िन-I पर 4 और सेक्िन-II पर 8) ➢ बे के साथ 400/220 केिी आईसीटी - 6 (सेक्िन-I पर 2 और सेक्िन-II पर 4) (ितचमान काय-च क्षेत्र म ें सेक्िन-I पर 2 400/220 आईसीटी के अजतररक्त) ➢ बे के साथ 400 केिी बस ररएक्टर : 2 (सेक्िन-II) ➢ 400 केिी सेक्िनलाइिेिन बे: 1- सेट ➢ 220 केिी लाइन बे: 10 (सक्े िन-I पर 4 और सेक्िन-II पर 6 ) (ितचमान कायच-क्षेत्र में सेक्िन-I पर 2 220 केिी बे के अजतररक्त) ➢ 220 केिी सेक्िनलाइिेिन बे: 1 सेट ➢ 220 केिी बीसी: 1 (सेक्िन-II के जलए) ➢ 400 केिी एचिीएसी जस्ट्िचयाडच और सभी संबद्ध उपकरण (दफल्टर सजित)/बस जिस्ट्तार, आदि के साथ संबद्ध इंटरकनेक्िन सजित 6000 मेगािाट, ± 800 केिी राघनेस्ट्िा (एचिीडीसी) [एलसीसी] टर्मचनल स्ट्टेिन (4x1500 मेगािाट) की स्ट्थापना । 2. राघनेस्ट्िा (िीआईएस) – बनासकांठा (पीिी) • मागच की लंबाई: 95 दकमी[भाग II—खण् ड 3(ii)] भारत का रािपत्र : असाधारण 9 765 केिी डी/सी लाइन 3. बनासकांठा (पीिी) एस/एस पर िो 765 केिी • 765 केिी लाइन बे – 2 लाइन ब े 4. 2x500 एमिीए, 400/220 केिी आईसीटी की • 500 एमिीए, 400/220 केिी आईसीटी – 2 संस्ट्थापना के साथ राघनेस्ट्िा पीएस (िीआईएस) • 400 केिी आईसीटी बे – 2 पर 220 केिी जस्ट्िचयाडच (बस सेक्िन-I) का • 220 केिी आईसीटी बे – 2 जनमाचण • 220 केिी बीसी – 1 5. एज़्योर पािर जसक्सटी थ्री प्राइिेट जलजमटेड • 220 केिी लाइन बे – 1 (2200001107) (300 मेगािाट) की सौर पररयोिना के इंटरकनेक्िन के जलए एक(01) 220 केिी लाइन बे (िीआईएस) (220 केिी बस सेक्िन-I पर) 6. सनश्योर सौरपाकच आरि ेिन प्राइिेट जलजमटेड • 220 केिी लाइन बे – 1 (350 मगे ािाट)(2200001018) की सौर पररयोिना के इंटरकनेक्िन के जलए एक 220 केिी लाइन ब े(िीआईएस) (220 केिी बस सेक्िन-I पर) नोट: • बनासकांठा एस/एस (पािरजग्रड) की टीएसपी उपयुचक्त क्रमाकं 3 पर कायच-क्षेत्र िायरे के जलए स्ट्थान उपलब्लध कराएगी। • डेढ़ ब्रेकर स्ट्कीम में व्यास (िीआईएस) को पूरा करन े के जलए आिश्यक बे भी टीएसपी द्वारा जनष्पादित दकए िाएंगे। [फा.स.ं 15/3/2018-रांस-भाग(4)] नाओरेम इंद्रकुमार चसंि, अिर सजचि (पारेषण) NOTIFICATION New Delhi, the 18th March, 2025 S.O. 1326(E).—In exercise of the powers conferred by sub-para 3.2 of Para 3 of the Guidelines circulated under Section 63 of the Electricity Act, 2003 (No. 36 of 2003), the Central Government had notified following scheme, for implementation under TBCB mode, vide Gazette Notification mentioned below:– Sl. Name of the Scheme Gazette Notification by which Scheme was No. notified 1. Transmission System for evacuation of RE power from S.O. 3545(E) dated 21.08.2024 [F. No. Raghanesda area of Gujarat– 3 GW under Phase-I 15/3/2018-Trans-Part(4)] 2. Now, the Central Government, on the recommendations of 26th National Committee on Transmission has decided to modify the scope of the aforementioned transmission scheme under TBCB mode as under:—10 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(ii)] Sl. Name & Scope of the Transmission Scheme No. 1. Transmission system for evacuation of RE power from Raghanesda Area of Gujarat-3 GW under Phase-I Tentative implementation timeframe: Sl. 1 to 3: 27 months, Sl. 4 & 5: 30.09.2027 (subject to minimum 27 months) & Sl. 6: 31.03.2028. BPC: PFC Consulting Limited Scope: Sl. Scope of the Transmission Scheme Capacity No. 1. Establishment of 4x1500 MVA, 765/400 kV • 765/400 kV, 1500 MVA ICT – 4 Nos. Substation near Raghanesda (GIS) with 2x330 (13x500 MVA single phase units including MVAR, 765 kV bus reactor and 2x125 one spare ICT Unit) MVAR, 420 kV bus reactor • 765 kV ICT bays – 4 Nos. • 400 kV ICT bays – 4 Nos. Future Space Provisions: • 765 kV Line bays – 2 Nos. ➢ 765/400 kV ICT along with bays – 4 Nos. • 1x330 MVAr, 765 kV bus reactor- 2 Nos. (on Sec-II) (7x110 MVAR single phase Reactors ➢ 765 kV line bays along with switchable including one spare Unit for bus /line line reactors – 8 Nos. (4 Nos. on Sec-I & reactor) 4 Nos. on Sec-II) • 765 kV Bus reactor bay – 2 Nos. ➢ 765 kV Bus Reactor along with bay: 2 • 125 MVAr, 420 kV reactor- 2 Nos. Nos. (on Sec-II) ➢ 765 kV Sectionaliser: 1-set • 400 kV Reactor bay- 2 Nos. ➢ 400 kV line bays along with switchable • 400 kV line bays - 4 Nos. (for line reactors– 12 Nos. (4 Nos. on Sec-I & interconnection of RE Projects) 8 Nos. on Sec-II) ➢ 400/220 kV ICT along with bays - 6 Nos. (2 Nos. on Sec-I & 4 Nos. on Sec-II) (in addn. to 2 Nos. 400/220 ICTs on Sec-I in present scope) ➢ 400 kV Bus Reactor along with bays: 2 Nos. (Sec-II) ➢ 400 kV Sectionalization bay: 1- set ➢ 220 kV line bays: 10 Nos. (4 Nos. on Sec- I & 6 Nos. on Sec-II) (in addn. to 2 Nos. 220 kV bays on Sec-I in present scope) ➢ 220 kV Sectionalization bay: 1 set ➢ 220 kV BC: 1 No. (for Sec-II) ➢ Establishment of 6000 MW, ± 800 kV Raghanesda (HVDC) [LCC] terminal station (4x1500 MW) along with associated interconnections with 400 kV HVAC Switchyard & all associated equipment (incl. filters)/ bus extension, etc. 2. Raghanesda (GIS) – Banaskantha (PG) 765 • Route length: 95 km kV D/c line 3. 2 Nos. 765 kV line bays at Banaskantha (PG) • 765 kV line bays – 2 Nos. S/s 4. Creation of 220 kV switchyard (Bus Sec-I) at • 500 MVA, 400/220 kV ICT – 2 Nos. Raghanesda PS (GIS) along with installation • 400 kV ICT bay – 2 Nos. of 2x500 MVA, 400/220 kV ICTs[भाग II—खण् ड 3(ii)] भारत का रािपत्र : असाधारण 11 • 220 kV ICT bay – 2 Nos. • 220 kV BC – 1 No. 5. 1 no. 220 kV line bay (GIS) (on 220 kV Bus • 220 kV line bay–1 No. Sec-I) for interconnection of Solar project of Azure Power Sixty Three Pvt. Ltd. (2200001107) (300 MW) 6. 1 No. 220 kV line bay (GIS) (on 220 kV Bus • 220 kV line bay–1 No. Sec-I) for interconnection of Solar project of Sunsure Solarpark RJ One Pvt. Ltd. (2200001018) (350 MW) Note: • TSP of Banaskantha S/s (POWERGRID) shall provide space for scope at Sl. 3 above. • Bay(s) required for completion of diameter (GIS) in one-and-half breaker scheme shall also be executed by the TSP. [F.No. 15/3/2018-Trans-Part(4)] NAOREM INDRAKUMAR SINGH, Under Secy. (Trans) Uploaded by Dte. of Printing at Government of India Press, Ring Road, Mayapuri, New Delhi-110064 and Published by the Controller of Publications, Delhi-110054.