Home India Ministry of Power In exercise of the powers conferred by clause a of section 1...
Date: 2016-09-08 Category: Extra Ordinary State: Union Government Country: India

In exercise of the powers conferred by clause a of section 14 of the Energy Conservation Act 2001 52 of 2001 the Central Government in consultation with the Bureau of Energy Efficiency

Issued by Ministry of Power · Not Applicable

Research with AI Agent Chat with Document Generate Summary Translate Helpful Share Add to Project Create Task

Executive Summary & Key Takeaways

Executive Summary: This notification specifies energy performance standards for star-labeled stationary storage-type electric water heaters in India, covering single-phase electric storage water heaters for household and similar purposes. It mandates compliance with Indian Standards and sets requirements for standing loss. The star rating plan is valid until June 30, 2017, and will be reviewed. Key Points / Main Content: Compliance Standards: Every storage-type electric water heater (up to 200 liters) manufactured, imported, or sold in India must: Meet compliance standards specified in Indian Standard IS 2082:1993 and IS 302221. Meet standing loss kWh/24 hours/45°C requirements. Definitions: Appliance/Unit: Electric storage water heaters as described in IS 2082:1993 and IS 302221. Authority: The Central Government. Participant: Manufacturers, importers, or retailers of water heaters. Rated Capacity: Zero negative tolerance on rated capacity. Rated Input: Electrical power input on the nameplate. Rated Power: Power input within 5-10% of rated capacity per IS 302221: 1992 and IS 3021: 2008. Standing Loss: Energy consumption after steady state, with no water drawn for 24 hours, calculated as per IS 2082:1993. Star Rating Band: Range of standing loss for determining star rating. Star Label: As described in Bureau of Energy Efficiency regulations. Star Rating Plan: Star rating indicates standing loss grade, from one to five stars. Star rating is calculated from the Star Rating Band. The star rating plan is valid from the date of notification to June 30, 2017. There is no tolerance for Star Rating Bands. Testing and Tolerance: Test Parameters: Rated capacity, rated power, and standing loss. Rated Capacity Tolerance: Zero negative tolerance. Rated Power Tolerance: Within 5 to 10% of the rated capacity. Verification: Samples will be picked up by the Bureau of Energy Efficiency or its designated agency for testing at accredited laboratories. Test reports must be submitted. Impact Analysis: Manufacturers, Importers, and Retailers of Electric Water Heaters: Impact: Must ensure that all manufactured, imported, or sold storage-type electric water heaters comply with the specified energy performance standards, testing parameters, and labeling requirements to achieve the designated star rating. Action Required: Review and update manufacturing processes, testing procedures, and labeling to meet the new standards and ensure compliance by the specified deadlines. Bureau of Energy Efficiency (BEE) and Designated Agencies: Impact: Responsible for overseeing the implementation and enforcement of the energy performance standards for electric water heaters. Action Required: Develop and implement verification processes, including sampling methodologies and testing protocols, to ensure compliance with the specified standards. Consumers: Impact: Will have access to star-labeled electric water heaters, providing them with information on energy efficiency and potential cost savings. Action Required: Utilize the star rating information to make informed purchasing decisions and select energy-efficient water heaters that meet their needs and budget. Central Government: Impact: Oversees and regulates the energy efficiency standards for electric water heaters. Action Required: Monitor the effectiveness of the star rating plan, review and update standards as necessary, and ensure compliance through appropriate enforcement measures.

Key Entities Referenced

Energy Conservation Act, 2001: A law enacted by the Central Government of India related to energy conservation. Bureau of Energy Efficiency: An organization consulted by the Central Government for specifying Energy Performance Standards. Energy Performance Standards: Standards specified for star labeled Stationary Storage Type Electric Water Heaters. Indian Standard IS 2082:1993: A standard that storage type electric water heaters shall meet the compliance standards. Indian Standard IS 302221: A standard that storage type electric water heaters shall meet the compliance standards. New Delhi: Location of publication of the notification. Ministry of Power: The ministry responsible for the notification regarding energy performance standards. National Accreditation Board for Testing and Calibration Laboratories: Accreditation body for laboratories where verification samples will be tested.
Official Source Record View Original Source →
See Full Document Text
jftLVªh laö Mhö ,yö&33004@99 REGD. NO. D. L.-33004/99 vlk/kj.k EXTRAORDINARY Hkkx II—[k.M 3—mi&[k.M (ii) PART II—Section 3—Sub-section (ii) izkf/dkj ls izdkf'kr PUBLISHED BY AUTHORITY la- 2203] ubZ fnYyh] c`gLifrokj] flrEcj 8] 2016@Hkkæ 17] 1938 No. 2203] NEW DELHI, THURSDAY, SEPTEMBER 8, 2016/BHADRA 17, 1938 िव(cid:7378)तु म(cid:7074)ं ालय अिधसचू ना नई (cid:7408)द(cid:7016)ल ी, 7 िसत(cid:7013)बर, 2016 का.आ. 2902(अ).—के(cid:7008) (cid:7076)ीय सरकार, ऊजा(cid:6981) सरं (cid:6979)ण अिधिनयम, 2001 (2001 का 52) क(cid:7409) धारा 14 के ख(cid:7003)ड (क) (cid:7367)ारा (cid:7079)द(cid:7275) अिधकार(cid:7298) का (cid:7079)योग करते (cid:7263)ए, ऊजा (cid:6981) द(cid:6979)ता (cid:7011)य ूरो के साथ परामश(cid:6981) से (cid:7021)ट ार लेबल यु(cid:6989)त िव(cid:7378)ुत भंडार (cid:7408)क(cid:7021)म के पानी के हीटर(cid:7298) के िलए िन(cid:7013) निलिखत ऊजा (cid:6981) खपत मानक िविन(cid:7416)द(cid:7020)ट (cid:7408)कए जात े ह(cid:7289) और इस मानक म (cid:7286) घरेलू और समान (cid:7079)कार के (cid:7079)योजन(cid:7298) के िलए एकल चरण िव(cid:7378)ुत भंडार (cid:7408)क(cid:7021)म के पानी के हीटर(cid:7298) और उबलते (cid:7263)ए तापमान के नीचे पानी गम(cid:6981) करन े को शािमल (cid:7408)कया गया, िजनका रेटेड वो(cid:7016)टेज 250 वो(cid:7016)ट स ेअिधक नह(cid:7277) ह,ै अथा(cid:6981)त ्:- 1. भारत म(cid:7286) िविन(cid:7414)मत, आयाितत अथवा बेचे जा रह े(cid:7079)(cid:7004)यके (cid:7408)क(cid:7021)म के इलिे (cid:6989)(cid:7069)क वॉटर हीटर (200 लीटर तक)- (क) भारतीय मानक आईएस 2082:1993 और आईएस 302-2-21 म(cid:7286) यथा िविन(cid:7416)द(cid:7020)ट मानक(cid:7298) का पालन करत े ह(cid:7298); (ख) िव(cid:7378)ुत पानी के हीटर क(cid:7409) (cid:7021)थायी खपत ((cid:7408)कलोवॉट/24 घंटा/45 िड(cid:7061)ी सिे (cid:7016)सयस) क(cid:7409) अपे(cid:6979)ा(cid:7312) का पालन करत े ह(cid:7298) । 2. ऊजा (cid:6981)िन(cid:7020) पादन मानक के (cid:7079)योजन(cid:7298) के िलए, संदभ (cid:6981)जब तक अ(cid:7008)याथा अपिे (cid:6979)त हो, - (क)(cid:32) सािध(cid:7074) या यिू नट स े अिभ(cid:7079)ेत ह ै जो भारतीय मानक आईएस 2082:1993 और आईएस 302-2-21 म (cid:7286) व(cid:7414)णत िव(cid:7378)ुत भंडार (cid:7408)क(cid:7021)म के पानी के हीटर (सभी (cid:7079)योजनीय सशं ोधन(cid:7298) सिहत, दोन(cid:7298)) स ेह।ै (ख)(cid:32) (cid:7079)ािधकरण से क(cid:7286)(cid:7076)ीय सरकार अिभ(cid:7079)ेत ह।ै (ग)(cid:32) भागीदारी स ेपानी के हीटर के िविनमात(cid:6981) ा, आयातक अथवा खदु रा (cid:7018)य ापारी अिभ(cid:7079)त ह।ै 4360 GI/2016 (1) (cid:32)2 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(ii)] (घ)(cid:32) रेटेड (cid:6979)मता (लीटर) से अिभ(cid:7079)ते ह ै जो हीटर(cid:7298) क(cid:7409) िनधा(cid:7407)(cid:6981) रत (cid:6979)मता पर शू(cid:7008)य नकारा(cid:7004)मक सिह(cid:7020)णुता और मािपत (cid:6979)मता िनधा(cid:7407)(cid:6981) रत (cid:6979)मता स ेकम नह(cid:7277) होगी। (ङ)(cid:32) रेटेड इनपटु से अिभ(cid:7079)ेत िव(cid:7378)ुत भंडार (cid:7408)क(cid:7021)म के पानी के हीटर के नामप(cid:7349) पर दशा(cid:6981)ई गई िबजली क(cid:7409) इनपुट स े ह।ै (च)(cid:32) रेटेड िव(cid:7378)तु ((cid:7408)कलोवॉट) स े अिभ(cid:7079)ेत ह ै जो िव(cid:7378)ुत का इनपुट आईएस 302-2-21 और आईएस 302-1:2008 (दोन(cid:7298) सभी लागू होन े स े संशोधन(cid:7298) सिहत) म (cid:7286) यथा िविहत िनधा(cid:7407)(cid:6981) रत (cid:6979)मता के +5%/ - 10% के भीतर होगा। (छ)(cid:32) (cid:7021)थायी हािन ((cid:7408)कलोवॉटघ.ं/24 घटं े/450 स.े) से अिभ(cid:7079)ेत ह ै जो (cid:7021)थायी हािन भरे (cid:7263)ए िव(cid:7378)ुत हीटर क(cid:7409) िव(cid:7378)ुत खपत ह ै जो िनरंतर ि(cid:7021)थर दशा के बाद (cid:7079)ा(cid:7009)त होती ह ै जब यह िव(cid:7378)ुत क(cid:7409) आप(cid:7414)ू त स े जड़ु ा होता ह ै और जब चौबीस घंटे तक कोई पानी नह(cid:7277) िलया जाता और (cid:7021)थायी हािन क(cid:7409) गणना आईएस 2082:1993 के अनसु ार क(cid:7409) जाएगी और इस मानक क(cid:7409) सारिणय(cid:7298) (यथा लाग)ू 1, 2 और 3 म(cid:7286) दी गई (cid:7021)ट ार रे(cid:7411)टग क(cid:7409) ज(cid:7272)रत(cid:7298) के अन(cid:7272)ु प होती ह।ै (ज)(cid:32) (cid:7021)टार रे(cid:7411)टग बड(cid:7289) से अिभ(cid:7079)ेत ह ै जो (cid:7021)थायी हािन ((cid:7408)कलोवॉटघ.ं/24 घंटे/45o से.) क(cid:7409) र(cid:7286)ज ह ै िजसका उपयोग (cid:7021) टार लेबल पर (cid:7021) टार(cid:7298) क(cid:7409) स(cid:6990)ं य ा िनधा(cid:6981)(cid:7407)रत करन ेके िलए (cid:7408)कया जाता ह।ै (झ)(cid:32) (cid:7021)टार लबे ल स े अिभ(cid:7079)ेत ह ै जो (cid:7021)टार लेबल, जसै ा िव(cid:7378)ुत हीटर के लेबल(cid:7298) के संबंध म (cid:7286) उनके वण(cid:6981)न और (cid:7079)दशन(cid:6981) क(cid:7409) िविध; िविनयमन, 2015 म (cid:7286)व(cid:7414)णत ह।ै 3. (cid:7021) टार रे(cid:7411)टग अथवा (cid:7021)ट ार (cid:7021)त र योजना: (1) "(cid:7021)टार रे(cid:7411)टग या (cid:7021)ट ार (cid:7021)तर" स े आशय िव(cid:7378)ुत भंडार (cid:7408)क(cid:7021)म के पानी के हीटर(cid:7298) के लेबल पर दशाई(cid:6981) गई (cid:7021)थायी खपत ((cid:7408)कलोवॉटघं./24 घंटे/45o से.) का (cid:7061)ेड ह।ै उपल(cid:7011)ध (cid:7021)ट ार एक (cid:7021)ट ार के अंतराल पर (cid:7008) यूनतम एक और अिधकतम पांच दशा(cid:6981)ए जात े ह।(cid:7289) (cid:7021)ट ार रे(cid:7411)टग क(cid:7409) गणना िन(cid:7013)न िलिखत सारणी म(cid:7286) यथा िविन(cid:7416)द(cid:7020)ट (cid:7021)ट ार रे(cid:7411)टग ब(cid:7289)ड से क(cid:7409) जाती ह।ै सारणी इस अिधसचू ना क(cid:7409) तारीख स े30 जनू 2017 तक (cid:7021)ट ार रे(cid:7411)टग योजना िविधमा(cid:7008)य होगी रेटेड 1 (cid:7021) टार 2 (cid:7021) टार 3 (cid:7021)ट ार 4 (cid:7021)ट ार 5 (cid:7021)ट ार (cid:6979)मता (लीटर) (cid:7021)थायी खपत ((cid:7408)कलोवॉटघं./24 घंटे/45o स.े) 6 ≤0.469 & > ≤0.426 & > ≤0.387 & > ≤0.352 & > ≤ 0.320 0.426 0.387 0.352 0.320 10 ≤0.587 & > ≤0.534 & > ≤0.485 & > ≤0.441 & > ≤ 0.401 0.534 0.485 0.441 0.401 15 ≤ 0.675 & > ≤0.614 & > ≤ 0.558 & > ≤0.507 & > ≤ 0.461 0.614 0.558 0.507 0.461¹Hkkx IIµ[k.M 3(ii)º Hkkjr dk jkti=k % vlk/kj.k 3 रेटेड 1 (cid:7021) टार 2 (cid:7021) टार 3 (cid:7021)ट ार 4 (cid:7021)ट ार 5 (cid:7021)ट ार (cid:6979)मता (लीटर) (cid:7021)थायी खपत ((cid:7408)कलोवॉटघं./24 घंटे/45o स.े) 25 ≤0.823 & > ≤0.748 & > ≤0.680 & > ≤0.618 & > ≤ 0.562 0.748 0.680 0.618 0.562 35 ≤0.940 & > ≤0.855 & > ≤0.777 & > ≤0.706 & > ≤ 0.642 0.855 0.777 0.706 0.642 50 ≤1.086 & > ≤0.988 & > ≤0.898 & > ≤0.816 & > ≤ 0.742 0.988 0.898 0.816 0.742 70 ≤1.233 & > ≤ 1.121 & > ≤ 1.019 & > ≤0.926 & > ≤ 0.842 1.121 1.019 0.926 0.842 100 ≤1.408 & > ≤ 1.280 & > ≤1.164 & > ≤1.058 & > ≤ 0.962 1.280 1.164 1.058 0.962 140 ≤1.586 & > ≤1.441 & > ≤1.310 & > ≤1.191 & > ≤ 1.083 1.441 1.310 1.191 1.083 200 ≤1.761 & > ≤1.601 & > ≤1.456 & > ≤1.323 & > ≤ 1.203 1.601 1.456 1.323 1.203 (cid:7021)टार रे(cid:7411)टग ब(cid:7289)ड के िलए कोई स(cid:7405)ता नह(cid:7277) होगी (जैसा उपरो(cid:7334) सारणी म(cid:7286) िविन(cid:7416)द(cid:7397) ह)ै और परीि(cid:6979)त उ(cid:7004)प ाद(cid:7298) का औसत टाइप िव(cid:7378)ुत पानी के हीटर के समान अथवा लेबल के िनचल े (cid:7021) तर स े बेहतर होगा और (cid:7021)टार रे(cid:7411)टग योजना क(cid:7409) समी(cid:6979)ा सारणी ‘क’ म (cid:7286) दी गई अविध समा(cid:7009) त होन े के बाद अथवा के(cid:7008)(cid:7076) ीय सरकार (cid:7367)ारा यथा: आवशयक समझी जाने वाली अविध पर क(cid:7409) जाएगी। 4. परी(cid:6979)ण और स(cid:7405)ता: (1) एक िव(cid:7378)ुत पानी के हीटर के (cid:7021)ट ार लेवल के अवधारण के िलए िन(cid:7013)न िलिखत परी(cid:6979)ण पैरामीटर(cid:7298) का परी(cid:6979)ण (cid:7408)कया जाएगा :- ‘परी(cid:6979)ण परै ामीटर' परी(cid:6979)ण मानक रेटेड (cid:6979)मता (लीटर) आई एस 2082 : 1993 और आईएस रेटेड िव(cid:7378)ुत ्((cid:7408)क. वॉ.) 302-2-21 : 2011 (दोन(cid:7298) सभी लागू (cid:7021) थायी हािन ((cid:7408)क. वॉ. घं.) (cid:7079)ित 24 घंटे : संशोधन(cid:7298) के साथ)’’ (2) हीटर(cid:7298) क(cid:7409) रेटेड (cid:6979)मता और मापन (cid:6979)मता पर शू(cid:7008)य नकारा(cid:7004)मक सहयता रेटेड (cid:6979)मता स ेकम नह(cid:7277) होगी. (3) िव(cid:7378)ुत का इनपुट, िनधा(cid:7407)(cid:6981) रत (cid:6979)मता के +5% से -10% के भीतर होगा। 5. परी(cid:6979)ण (cid:7407)रपोट(cid:6981): (cid:7079)(cid:7004)य के इकाई के परी(cid:6979)ण(cid:7298) के प(cid:7407)रणाम इस अिधसूचना के उपाबंध म (cid:7286)(cid:7408)दए गए (cid:7272)प म(cid:7286) बताए जाएंगे। 6. स(cid:7004)यापन / अनपु ालन क(cid:7409) जाचं के िलए नमनू ा लने े क(cid:7409) िविध: स(cid:7004)यापन के (cid:7079)योजन के िलए (cid:7079)(cid:7004)य ाियत (cid:7079)योगशाला अथात(cid:6981) ् रा(cid:7020) (cid:7069)ीय (cid:7079)(cid:7004) यायन बोड (cid:6981) जाचं एवं अंशशोधन (cid:7079)योगशाला म(cid:7286) जांच के िलए ऊजा (cid:6981) द(cid:6979)ता (cid:7011)य ूरो या इसक(cid:7409) नामो(cid:7408)(cid:7374)(cid:7020)ट अिभकरण (cid:7367)ारा नमून ेएक(cid:7074) (cid:7408)कए जाएंगे।4 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(ii)] उपाबधं परी(cid:6979)ण(cid:7298) के प(cid:7407)रणाम क(cid:7409) (cid:7407)रपो(cid:7419)टग के िलए (cid:7079)प(cid:7074) परी(cid:6979)ण (cid:7407)रपोट(cid:6981) स.ं : तारीख: िव(cid:7378)ुत भंडार (cid:7408)क(cid:7021)म के पानी केहीटर का (cid:7011)यौरा (i)(cid:32) (cid:7081)ांड : (ii)(cid:32) (cid:7079)कार : (iii)(cid:32) मॉडल का नाम : (iv)(cid:32) रे टेड (cid:6979)मता (लीटर) : (v)(cid:32) रेटेड इनपुट पावर (के. ड(cid:7011) (cid:7016) य)ू : (vi)(cid:32) घोिषत (cid:7021)थायी हािन : 2.(cid:32) परी(cid:6979)ण साराशं (i)(cid:32) लाग ूके (cid:7272)प म (cid:7286)(cid:7079)(cid:7004)य ेक जांच (cid:7079)कार के िलए इस पेज क(cid:7409) एक अलग (cid:7079)ित पणू (cid:6981)कर(cid:7286) (ii)(cid:32) जांच क(cid:7409) तारीख : (iii)(cid:32) जांच का(cid:7414)मक का नाम: (iv)(cid:32) जांच का (cid:7079)कृित और जांच के (cid:7011)यौरे: (v)(cid:32) साधारण जांच ि(cid:7021)थित : (vi)(cid:32) ऊजा (cid:6981)खपत जांच (cid:7407)रपोट(cid:6981) ((cid:7079)(cid:7004)य के इकाई क(cid:7409) जांच के िलए (cid:7079)(cid:7021) तुत (cid:7408)कया जाना ह)ै सं(cid:7079)े(cid:6979)ण और प(cid:7407)रणाम : जाचं (cid:7407)रपोट(cid:6981) फॉमट(cid:7287) : मॉडल : (cid:6979)मता : जांच के िववरण प(cid:7407)रवेश का तापमान -(cid:32) जांच आरंभ करना : -(cid:32) जांच समा(cid:7009) त करना : -(cid:32) जांच अविध (t ) आरं भ करना : 1 -(cid:32) ऊजा (cid:6981)खपत के िववरण -(cid:32) समय (t ) ((cid:7408)क. वॉ. घं.) म (cid:7286)ऊजा(cid:6981) खपत (t ) 1 1 24 घंटे ((cid:7408)क. वॉ. घ.ं / 24 घंटे) म (cid:7286)ऊजा(cid:6981) खपत : औसत तापमान (एम1) िड(cid:7061)ी से.) : (cid:7021) थायी हािन ((cid:7408)क. वॉ. घं. / 24 घंटे / 45 िड(cid:7061)ी से.) [फा. सं. 13/14/2014 – ईसी पी आई] राज पाल, आ(cid:7414)थक सलाहकार¹Hkkx IIµ[k.M 3(ii)º Hkkjr dk jkti=k % vlk/kj.k 5 MINISTRY OF POWER NOTIFICATION New Delhi, the 7th September, 2016 S.O. 2902(E).—In exercise of the powers conferred by clause (a) of section 14 of the Energy Conservation Act, 2001 (52 of 2001), the Central Government in consultation with the Bureau of Energy Efficiency, hereby specifies the Energy Performance Standards for star labeled Stationary Storage Type Electric Water Heaters and the standard covers the single phase electric storage water heaters for household and similar purposes and intended for heating water below boiling temperature, their rated voltage being not more than 250 V, namely:- 1. Every storage type electric water heater (up to 200 litre) being manufactured, imported, or sold in India shall- (a) meet the compliance standards as specified in Indian Standard IS 2082:1993 and IS 302-2-21; (b) meet the standing loss (kWh/24 hours/45 degree C) requirements of water heater. 2. For the purposes of Energy Performance Standard, unless the context otherwise requires,-- (a) “Appliance” or ”Unit” means an electric storage water heaters described in Indian standard IS 2082:1993 and IS 302-2-21 (both with all amendments applicable); (b) “Authority” means the Central Government; (d) “Participant” means manufacturers, importers or retailers of the water heater; (e) “Rated capacity (Litre)” means zero negative tolerance on rated capacity of heaters and the measured capacity shall not be less than the rated capacity; (f) “Rated input” means the electrical power input shown on the nameplate of the electric storage water heaters; (g) “Rated Power (kW)” means the power input, which shall be within +5% /-10% of the rated capacity as prescribed in IS 302-2-21: 1992 and IS 302-1: 2008 (both with all applicable amendments); (h) “Standing loss (kWh/24 hour/45oC)” means the energy consumption of a filled water heater, after steady state conditions have been reached when connected to electrical supply, and when no water is drawn for twenty-four hours and the standing loss shall be calculated as per IS 2082:1993 and comply with the star rating requirement as given in Tables (as applicable) 1, 2 and 3 of this standard; (i)(cid:32) “Star Rating Band” means a range of standing loss (kWh/24Hr/45oC) which is used for determining the number of stars displayed on the star label; and (j) “Star Label” means Star label as described in the Bureau of Energy Efficiency (Particulars and Manner of their Display on Labels of Water Heater) Regulations, 2015. 3.(cid:32) Star Rating or Star Level Plan.- (1) “Star rating or star level” means the grade of standing loss (kWh/24hr/45oC) displayed on the label of the electric storage water heaters. The available stars are between a minimum of one and a maximum of five shown in one star interval. The star rating is calculated from the Star Rating Band as specified in the following table, namely:- TABLE Star rating plan shall be valid from the date of this notification to the 30th June, 2017 Rated 1 star 2 star 3 star 4 star 5 star Capacity Standing Losses (kWh/24 hour/45°C) (Litres) 6 ≤0.469 & > 0.426 ≤0.426 & > 0.387 ≤0.387 & > 0.352 ≤0.352 & > 0.320 ≤ 0.320 10 ≤0.587 & > 0.534 ≤0.534 & > 0.485 ≤0.485 & > 0.441 ≤0.441 & > 0.401 ≤ 0.401 15 ≤ 0.675 & > 0.614 ≤0.614 & > 0.558 ≤ 0.558 & > 0.507 ≤0.507 & > 0.461 ≤ 0.461 25 ≤0.823 & > 0.748 ≤0.748 & > 0.680 ≤0.680 & > 0.618 ≤0.618 & > 0.562 ≤ 0.562 35 ≤0.940 & > 0.855 ≤0.855 & > 0.777 ≤0.777 & > 0.706 ≤0.706 & > 0.642 ≤ 0.642 50 ≤1.086 & > 0.988 ≤0.988 & > 0.898 ≤0.898 & > 0.816 ≤0.816 & > 0.742 ≤ 0.742 70 ≤1.233 & > 1.121 ≤ 1.121 & > 1.019 ≤ 1.019 & > 0.926 ≤0.926 & > 0.842 ≤ 0.842 100 ≤1.408 & > 1.280 ≤ 1.280 & > 1.164 ≤1.164 & > 1.058 ≤1.058 & > 0.962 ≤ 0.9626 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(ii)] Rated 1 star 2 star 3 star 4 star 5 star Capacity Standing Losses (kWh/24 hour/45°C) (Litres) 140 ≤1.586 & > 1.441 ≤1.441 & > 1.310 ≤1.310 & > 1.191 ≤1.191 & > 1.083 ≤ 1.083 200 ≤1.761 & > 1.601 ≤1.601 & > 1.456 ≤1.456 & > 1.323 ≤1.323 & > 1.203 ≤ 1.203 (2) There shall be no tolerance for Star Rating Bands (as specified in above Table) and the average of products tested must be at par type electric water heater or better than the Label threshold and the star rating plan shall be reviewed after the expiry of period given in Table above or as deemed necessary by the Central Government. 4.(cid:32) Testing and Tolerance. (1)(cid:32) For the purpose of determining the star level of a water heater, the following test parameters shall be tested, namely:- “Test Parameters Test Standards Rated capacity (Litre) IS 2082:1993 & IS 302-2-21: 2011 (both with all applicable amendments).” Rated Power (kW) Standing loss (kWh) per 24 hour: (2) There shall be zero negative tolerance on rated capacity of heaters and the measured capacity shall not be less than the rated capacity. (3) The power input shall be within +5% to -10% of the rated capacity. 5. Test Report. The result of the tests of each unit shall be reported as given in Annexure to this notification 6. Sampling methodology for verification/compliance check.- For the purpose of verification, the samples will be picked up by Bureau of Energy Efficiency or its designated agency for testing at the National Accreditation Board for Testing and Calibration Laboratories accredited laboratory. Annexure Form for reporting the results of tests Test Report No. Date: 1.(cid:32) Details of Stationary Storage Electric Water Heater (i)(cid:32) Brand: (ii)(cid:32) Type: (iii)(cid:32) Model name: (iv)(cid:32) Rated capacity (Litre): (v)(cid:32) Rated Input Power (kW): (vi)(cid:32) Declared Standing Loss (kWh): 2.(cid:32) Test summary (i)(cid:32) Complete a separate copy of this page for each test type, as applicable (ii)(cid:32) Date of test: (iii)(cid:32) Name of the Testing personnel: (iv)(cid:32) Nature of Test / Test details: (v)(cid:32) General Test condition:, (vi)(cid:32) Energy Consumption Test Report (to be submitted for each unit tested): Observations and Results:¹Hkkx IIµ[k.M 3(ii)º Hkkjr dk jkti=k % vlk/kj.k 7 Test Report Format: Model: Capacity: Test Details Ambient Temperature -(cid:32) Test Started on: -(cid:32) Test Ended on: -(cid:32) Test Duration (t ) started on: 1 Energy Consumption Details -(cid:32) Energy consumption (t ) in time (t ) (kWh) : 1 1 Energy Consumption in 24 h (kWh / 24 hr) : Mean Temperature (M1) (degree C) : Standing Loss (kWh / 24 hr / 45 degree C) : [No. 13/14/2014-EC P I] RAJ PAL, Economic Advisor (cid:32) (cid:32) (cid:32) (cid:32) (cid:32) (cid:32) (cid:32) (cid:32) (cid:32) (cid:32) (cid:32) Uploaded by Dte. of Printing at Government of India Press, Ring Road, Mayapuri, New Delhi-110064 and Published by the Controller of Publications, Delhi-110054.

Continue your research