See Full Document Text
(cid:315)(cid:175)ೇಷ (cid:170)ಾಜ(cid:205) ಪ(cid:294)(cid:206)(cid:144)ೆ
¨Ás U À – 4ಎ , 22 , 2026 01 1948) . 387
Part – IVA BENGALURU, FRIDAY, 22, MAY, 2026 ( JYAISTHA , 01, SHAKAVARSHA, 1948) No. 387
GOVERNMENT OF KARNATAKA
No.UDD 17 TTP 2025(E) Karnataka Government Secretariat
Vikasa Soudha,
Dr. B.R.Ambedkar Veedhi,
Bangalore, Dated:22.05.2026.
NOTIFICATION
In exercise of the powers conferred under Section 13-E of the Karnataka Town
and Country Planning Act, 1961, the Government of Karnataka had notified
amendments to the Zonal Regulations of all approved Master Plans currently in force
vide notification No.UDD 17 TTP 2025, dated 11.11.2025 published in No.724 Part IVA
of the State Gazette dated 11.11.2025 inviting objections and suggestions from the
public within 30 days of its publications. This initiative is aimed at ensuring greater
clarity, inclusiveness, and ease of compliance, while promoting sustainable urban
development, enhancing local economic opportunities, supporting Micro, Small and
Medium Enterprises (MSMEs), and enabling faster implementation of urban
infrastructure. These amendments are framed in alignment with the Compliance
Reduction and Deregulation Priority Areas, as recommended by the Government of
India.
Whereas objections or suggestions received by the Government have been
examined and taken in to consideration
Now therefore in exercise of powers conferred under Section 13-E of the
Karnataka Town and Country Planning Act, 1961the Government hereby notifies the
following regulations as under.
Regulations
Title and Applicability.- (1) These regulations may be called the Amendment to Zonal
Regulations of all approved Master Plans of the Local Planning Areas (except the master
plans within Bengaluru Metropolitan Region including GBA, BDA and all planning
(1)2
authorities within Bengaluru Metropolitan Region and the Mangaluru Local Planning
Area).
(2) They shall come into force from the date of publication in the Official Gazette.
1. The Zonal Regulations of the Master Plans, which are classified into various
zones, the following shall be substituted, pertaining to Land Use Zones.
LAND USE ZONES
1.1 Classification of Land into various zones
1. Residential (R)
2. Commercial (C)
3. Industrial (I)
4. Public and Semi-public (P & SP)
5. Transportation and Communication (T )
6. Public Utilities (PU)
7. Park and Open Space/ Play Ground (P)
8. Agriculture (A)
1.2 List of land use categories permissible in various zones
Various land uses permissible within each zone are listed below. Land uses are
grouped according to the nature and intensity of use in an ascending manner. For e.g.:
C-4: indicates C-Commercial and 4- indicates the order within the category. The C-4
list includes all land uses permissible specific to C-4 and the lower order uses of C-3,
C-2, and C-1 unless otherwise specifically mentioned.
The various codes used include:
a. Residential: R
b. Commercial:C-1 to C-5
c. Industrial: I-1 to I-5
d. Transportation: T-1 to T-4
e. Public and Semi Public: P&SP-1 to P&SP -4.
Though the various uses are listed, the corresponding space standards for
buildings/uses are to be referred. The two main parameters to allow a particular use
are requisite size of Plot and the minimum width of Road.
1.3 Regulations applicable to zones
I. Residential Land Use Zone- R
Sl. No Residential Land Uses
1. Plotted residential developments
2. Villas, semi detached houses
3. Apartments, Hostels, Dharma shala
4. Multi Dwelling Housing, Service Apartments.
5. Group Housing (Development Plans), Affordable Housing
6 Bus bays, auto stand, bus shelters information kiosk
7 Metro station, parking areas3
8 Multi-level car parking as part of residential apartments to cater the needs
of residents only
Permissible Mixed Uses
Area Permissible
Sl. Plot size Road width
Uses permissible
no. (in sq.m) Minimum (in m)
1 2 3 4 5
1 Up to 240 12.0 m C-1, T-1&P&SP-1 Up to 20 % of the total
built up area or 50
241 up to C-1,C-2, I-1, sq.mt whichever is
2 12.0 to 18.00 m
1000 P&SP-1, P&SP-2& T-1 higher
C-1, C-2, I-1, I-
1001 up to
3 18.00 to 24.00 m 2,P&SP-1,P&SP-2,
2000 Up to 10 % of the total
P&SP-3& T-1
built up area or 100
sq.mt whichever is
C-1, C-2, I-1, I-
2001 up to higher
4 24.00 to 30.00 m 2,P&SP-1, P&SP-
3500
2, P&SP-3, T-1&T-2
C-1, C-2, C-3, I-1, I-2,
3501 and
5 Above 30.00 m I-3, P&SP-1, P&SP-
above
2, P&SP-3, T-1 & T-2
Note- Permissible uses as mentioned in the above table in residential zone may
be permitted on Ground floor or any other floor in a residential dwelling only if separate
means of access/ staircase and sufficient parking space as required are provided.
Uses not permitted: C-4, C-5, I-4, I-5, P&SP-4, T-3 and T-4
II. Commercial Land Use Zone- C: Permissible land uses- All uses from C1
to C5
1. Commercial Land Use – C1
Sl. No Commercial Land Uses permissible
1 Petty shops, Newspaper, stationery and milk booth, vulcanizing shops
2 Tutorial centers not exceeding 50 sq.m
3 STD/ FAX/internet center/ ATM centers
4 Hair dressing and beauty parlors
5 Offices/ clinics belonging to “Professional services" category and self-owned
not exceeding 50 sq.m
6 Tailoring, dry cleaners
7 Bakery and sweetmeat shop
8 Pathological labs.
9 Recreational Clubs as per prescribed Space Standards4
2. Commercial Land Use – C2
Sl. No Commercial Land Uses permissible
1 Eateries such as darshinis, tea stalls, and takeaways
2 Gyms, orphanages, old age homes clinics
3 Retail shops & hardware shops
4 Banks, ATMS, insurance and consulting and business offices
5 Mutton and poultry stalls, cold storages
6 Job typing/ computer training institutes, cybercafé, internet browsing.
7 Uses for small repair centers- electronic, mechanical, automobile,
etc
8 Photo Studio
9 Nursing homes and poly clinics/ dispensaries /labs subject to minimum
300sq.m plot size and NOC from pollution control board after adequate
parking facility is provided.
10 Fuel stations and pumps, LPG storage as per prescribed Space Standards
11 Kalyana mantaps as per prescribed Space Standards
12 All the uses of C1 are permitted
3. Commercial Land Use – C3
Sl. No Commercial Land Uses permissible
1 Commercial and corporate offices
2 Retail Shopping complexes
3 Restaurants and Hotels
4 Convention centers and banquet halls
6 Financial/Institutional Buildings
7 Cinema and multiplexes
8 Places of assembly, exhibitions centers
9 Entertainment and amusement centers.
10 Hospitals and specialty hospitals
11 Automobile repair and garage centers, spares and stores
12 All uses of C1 & C2 are permitted
4. Commercial Land Use – C4
Sl. No Commercial Land Uses permissible
1 Sale of second-hand junk goods, junk yards
2 Warehouses and storage areas for goods
3 Whole sale and trading
4 All uses of C1, C2 & C3 are permitted
5. Commercial Land Use – C5
Sl. No Commercial Land Uses permissible
1 Wholesale and warehouses -business
2 Agro Mandis
3 Heavy goods markets
4 All uses of C1, C2, C3 & C4 are permitted5
Other uses permitted
R, I-1, I-2, I-3, T-1, T-2, T-3, P&SP-1, P&SP-2 and P&SP-3
Note: All uses permitted are subjected to space standards and road width.
Uses not permitted
I-4, I-5, T-4, P&SP-4
III. Industrial Land Use Zone- I:Permissible land uses – All uses from I-1 to I-
5
1. Industrial Land Use – I-1(House hold industries)
Tiny and household industries
1)Food products
Preparation of bakery products &confectionaries,
Candies, sweets, ice & ice creams, Biscuit making, huller and flour mills,
Aerated water and food beverages.
Supari and masala grinding,
Coffee powder, packing, milk and dairy products,
Juice crusher sand processing, etc
2)Textile products
Embroidery works, handloom and power looms
Hosiery, netted garments, crepe, cotton and silk printing, tailoring apparels.
Bedding material, textile bags, mosquito nets, others;
3)Wood products and carpentry
Manufacture of wooden furniture, fixtures, toys, mirrors & photo frames
Bamboo and cane furniture works, Repair and sale of wood junk, etc
4)Paper products and printing
Manufacturing of cartons for packing,
Printing, publishing, book binding, engraving, etching
Making of stationery-post cards, mathematical items, block making etc
5)Other works such as
Ornamental jewelry, gold and silver thread,
Repair of kitchen related equipment’s, Porcelain wares
Medicines, wax polishing, & washing soaps, candles and wax products
Chalk, crayons and artists color, Musical instruments
Laundries, bleaching, dyeing, Photo processing laboratories
Cement moulded products, Plaster of Paris
Repacking/mixing of liquids, powder, pastes, not involving hazardous
materials etc
6)Tobacco and Agarbathis
Rolling of Beedis, Agarbathis and packing etc
7)Leather products
Manufacture and repair of finished leather goods
Upholstery, suitcases etc
8)Rubber and plastic products
Re-treading, recapping and vulcanizing, toy making
Rubber/polymer stamp, brush making, conduit pipes fabrication
Buckets and house hold plastic products
Manufacturing of rubber balloons, hand gloves, other products6
Above Uses are permitted subject to condition that the zone permits the extent of area
and the power consumption does not exceed 5 KW. The activity follows the prescribed
space standards.
Note: The power required for air conditioners, lifts & computers, shall be excluded
while calculating the above kilowatt.
2. Industrial Land Use – I-2 (Service industries)
Sl. NoIndustrial Land Uses permissible
1 R & D labs, Test centers, IT, BT, BPO activities
2 All uses included in the I-1 category
3. Industrial Land Use – I-3(Light Industries)
Sl. No Industrial Land Uses permissible
1 All uses in I-1 and I-2 included
Uses permitted subject to condition that the zone permits the extent of the area and
power consumption, the activity follows the required space standard, performance
characteristics such as Noise, Vibration, Dust, Odour, Effluent, General nuisance
4. Industrial Land Use – I-4 (Medium Industries)
Sl. No Industrial Land Uses permissible
1 All uses of I-1, I-2 & I-3 included
2 Warehousing, loading and unloading platforms to be provided
Uses permitted subject to condition that the zone permits the extent of the area and
installed power and performance characteristics such as Noise, Vibration, Dust,
Odour, Effluent, General nuisance are to be considered.
5. Industrial Land Use – I-5(Heavy Industries)
Sl. No Industrial Land Uses permissible
1 All uses of I-1, I-2, I-3 & I-4 are included
2 Hazardous industries and heavy manufacturing industries
Uses permitted subject to condition that the zone permits the extent of the area and
installed power and performance characteristics such Noise, Vibration, Dust, Odour,
Effluent, General nuisance are to be considered
Other Uses Permitted
R (as an ancillary use like housing for industrial workers not exceeding 10% of
the total land area), C-1, C-2, T-1, T-2, T-3 and T-4
Uses Not Permitted
R, C-3, C-4, C-5, P&SP-1, P&SP-2, P&SP-3, P&SP-4.
IV. Public and Semi –Public Land Use Zone– P&SP: Permissible land uses- All
uses from P&SP-1 to P&SP-47
1. Public& Semi-Public Land Use – P&SP-1
Sl. No Public & Semi-Public Land Uses permissible
1 Sub offices of utilities up to 50sq.m
2 Police stations, post offices
3 Primary schools subject to space standards
5 Parks, Play grounds and Maidans
6 Telecommunication/micro wave under special case
7 Nursery creches
8 Spastic Rehabilitation centers, Orphanages, Govt dispensaries
9 Public distribution system shops
10 Fire stations
11 Bill collection centers
12 Traffic and Transport related facilities
13 Places of worship, Dharmashala, hostels
14 Dhobi Ghat
15 Broadcasting and Transmission stations
16 Public library
2. Public& Semi-Public Land Use – P&SP-2
Sl. No Public & Semi-Public Land Uses permissible
1 All uses of P&SP-1are permissible.
2 Burial grounds, crematorium under special circumstances.
3 Nursery school subject to a plot size of min 300 sq.m
3. Public& Semi-Public Land Use – P&SP-3
Sl. No Public & Semi-Public Land Uses permissible
1 All uses of P&SP-1andP&SP-2are permissible.
2 Higher primary schools, Integrated Residential Schools.
3 Health centers and Hospital.
4 Research institutions subject to the size
5 Government buildings, auditoriums, cultural complexes,
6 Educational Institutions, Colleges
4. Public& Semi-Public Land Use – P&SP-4
Sl. No Public & Semi-Public Land Uses permissible
1 All uses of P&SP-1,P&SP-2, and P& SP-3 are permissible
2 Meteorological observatories
3 Airport and ancillary uses
Uses permitted
C-1, C-2, T-1 &T-2,
Uses not permitted
R, C-3, C-4, C-5, I-1, I-2, I-3, I-4, I-5, T-3&T-4
V. Transportation and Communication Land Use Zone- T:Permissible land
uses-All uses from T1 to T-48
1. Transportation and Communication Use T-1:
Sl. Transportation and Communication Land Uses permissible
No
1 Bus bays, Auto stand, Bus shelters, information kiosk
2 Metro stations, parking areas
3 Multi-level car parking
4 Filling stations, service stations in accordance with the conditions specified in
the notification No. UDD 93 MYAP 2020, dated 12.03.2025
2. Transportation and Communication Use T-2
Sl. No Transportation and Communication Land Uses permissible
1 Transport offices
2 Workshops and garages
3 All uses of T-1 are permitted
3. Transportation and Communication Use T-3
Sl. Transportation and Communication Land Uses permissible
No
1 Automobile spares and services, Godowns,
2 Loading and unloading platforms (with/without Cold storage facility), weigh
bridges.
3 Bus terminals, Road transport uses
4 All uses of T-1 &T-2 are permitted
4. Transportation and Communication Use T-4
Sl. Transportation and Communication Land Uses permissible
No
1 Ware houses, Storage depots
2 Truck terminals
3 Railway station, Yards, Depots, Airport
4 Special warehousing, cargo terminals.
5 All ancillary (complimentary) uses for above categories(decision of the authority
shall be final)
6 All uses of T-1, T-2 &T-3 are permitted
Uses permitted
As ancillary use only: P&SP-1 and P&SP-2, C-1, C-2 and C-3, I-1, I-2 and I-3not
exceeding 45% of the permissible FAR of the project when taken up by the
central, state Government agencies and public under takings; and not exceeding
20% of the total built up area in other cases.
Uses not permitted
R, P&SP-3, P&SP-4, C-4, C-5, I-4 and I-59
VI. Parks, Open Spaces and Play Ground Zone – P
1. Permissible land uses:
i. Uses permissible include: Sports grounds, stadium, play grounds, parks,
swimming pools, cemeteries, garden land and crematoria.
Ancillary Uses permissible under special circumstances by the authority:
ii.
Open air theatres, indoor recreational uses, dwelling for watch and ward,
sports clubs, libraries, milk booths, HOPCOMS, the area of such use shall
not exceed 5% of the total area and shall not be more than G+ 1 floor in
any case.
2. Uses not permitted
All other uses not mentioned in above uses (permitted and uses permitted by
Competent Authority), Any building or structure which is not required for open air
recreation.
VII. Public Utilities Zone – PU
1. Uses permitted
Water supply and Sanitary installations including treatment plants and disposal
work, Storage reservoirs, drying beds, Dumping yards, Power plants, Transformers,
High- and low-tension transmission lines, Sub-stations, Gas installations and Gas
works, Fire stations, Microwave towers, public toilets and such other public utilities.
radio transmitter and wireless stations, telecommunication center, telephone
exchange, Canteens, Offices, ATM, Indoor recreational use, dwellings required for
essential staff for maintenance and functioning of public utility uses in their own
premises as an ancillary to the respective institutions not exceeding 10% of the total
area.
2. Uses not permitted
All other uses not mentioned in above uses (permitted and uses permitted by
Competent Authority)
VIII. Agriculture Zone – A
1. Uses permitted
Sl. No Agriculture Land Uses permissible
1 Agro processing units using locally produced agriculture produce as raw
materials.
2 Urban amenities such as burial grounds, sports grounds, stadium,
playgrounds, parks and garden land, education and health institutions not
exceeding 20% of the sital area and a building height of G+1 floor only shall
be permitted.
3 Public utilities such as solid waste landfills, water treatment plants, power
plants, fuel stations and other highway amenities such as weigh bridges,
check posts, tollgates, having access to major roads.10
4 Agriculture, Horticulture, Dairy, Milk Chilling centres, Farm houses and
accessory not exceeding 250 sq.m of plinth area within the plot area
limitation of 1.2 Ha limited to G+1 floor.
5 Exhibition centres, storage and sale of farm products, Clubs& cultural
buildings not exceeding 5% of the sital area of the land and a building height
G+1 floor shall be permitted.
6 Service and repairs of farm machinery.
7 Piggeries and poultry farms, livestock rearing.
8 Brick Kilns.
9 Whenthelandismorethan40.0hainextent,Golfcoursealongwithancillaryuses
like administrative office, guest rooms/guest houses and dining facilities up
to 20% of the sital area subject to a building height of G+1 floor only shall be
permitted.
10 Temporary activities such as stone quarries, crushers, and borrow pits may
be permitted for a specific duration, subject to approval from the competent
authority and compliance with environmental and pollution control norms.
11 Renewable energy projects such as solar power plants and windmills shall
be permitted, provided that such installations do not permanently alter the
agricultural character of the land and necessary clearances are obtained
from the competent authorities
12 LPG Gas Godowns in accordance with the conditions specified in the
notification No. UDD 93 MYAP 2020, dated 12.03.2025 and similar low-
hazard storage facilities may be permitted, subject to clearance from the
Petroleum and Explosives Safety Organization (PESO) and approval from the
competent authority, ensuring adequate safety distances, access, and
environmental safeguards
2. Uses not permitted
All other uses not mentioned in above uses (permitted and uses permitted by
Competent Authority)
1.4 Minimum setbacks for Industrial and Commercial buildingsin industrial
areas
1. Regulations for Industrial (General) and Commercial buildings in industrial
areas (Setbacks for height below 21 m; FAR and Road width applicable to
all buildings irrespective of the Height of the building)
Setback (m)
Extent of plot Permissible Minimum Road
Sl.No.
(sq.m.) Front Rear Left Right FAR width (m)
1 Upto 255 2.0 1.0 1.0 1.0 1.50 9.0
2 Above 255 2.5 1.5 1.0 1.0 1.50 9.0
upto 510
3 Above510 3.0 2.0 1.5 1.5 1.75 12.0
upto 1020
4 Above1020 6.0 3.0 3.0 3.0 1.75 12.0
upto 2025
5 Above 2025 7.0 5.0 5.0 5.0 2.0 12.0
upto 4050
6 Above 4050 8.0 6.0 6.0 6.0 2.0 12.0
upto 810011
7 Above 8100 8.0 6.0 6.0 6.0 2.25 18.0
upto 12200
8 Above 12200 8.0 6.0 6.0 6.0 2.50 18.0
Note:-
1. Premium FAR shall be availed in accordance with the prevailing rules.
2. Wherever TDR is permitted on a building site, then the maximum additional FAR
due to TDR and the Premium FAR together shall not exceed 0.6 times the
permissible FAR
3. In case the building height exceeds 15.0 m, the minimum setback/driveway
shall be 6.0 m. The minimum 6.0 m setback/driveway specified herein, or the
setback mentioned in the table above, whichever is greater shall apply.
4. For road widths below 12.0m I-1 Category industries only shall be permitted.
5. In case of existing developments on roads below 9.0m, redevelopment shall be
considered in accordance to these regulations.
(2) Setbacks for Industrial (General) and Commercial buildings in industrial
areas 21m and above in height
Exterior setback to be left on all
Sl.
Height of building in m sides
no
(front, rear and sides in m)
1 21.0 m up to 24.0 m 7.0
2 Above 24.0 m up to 27.0 m 8.0
3 Above 27.0 m up to 30.0 m 9.0
4 Above 30.0 m up to 35.0 m 10.0
5 Above 35.0 m up to 40.0 m 11.0
6 Above 40.0 m up to 45.0 m 12.0
7 Above 45.0 m up to 50.0 m 13.0
8 Above 50.0m up to 55.0m 16.0
9 Above 55.0m up to 70.0m 17.0
10 Above 70.0m up to 120.0m 18.0
11 Above 120.0m 20.0
(3) Regulations for flatted factories for height below 21m
Set back(m) Permissible Minimum road
Sl no Extent of plot Premium FAR width(m)
front Rear left right FAR
1 Upto to 255 2.0 1.0 1.0 1.0 1.75 - 9.0m
2 Above 2.5 1.5 1.0 1.0 2.00 0.25 12.0m
255-510
3 Above 3.0 2.0 1.5 1.5 2.00 0.25 12.0m
510-1020
4 Above 4.0 3.0 3.0 3.0 2.25 0.25 12.0m
1020-2025
5 Above 5.0 4.0 5.0 5.0 1.75 1.0 18.0m
2025-405012
6 Above 6.0 5.0 6.0 6.0 2.0 1.2 24.0m
4050-8100
7 Above 7.0 6.0 6.0 6.0 2.25 1.35 30.0m
8100-12200
8 Above 12200 8.0 6.0 6.0 6.0 2.5 1.5 30.0m
Note:-
1. In case the building height exceeds 15.0 m, the minimum
setback/driveway shall be 6.0 m. The minimum 6.0 m setback/driveway
specified herein, or the setback mentioned in the table above, whichever
is greater shall apply.
2. Wherever TDR is permitted on a building site then, the maximum
additional FAR due to TDR and the Premium FAR together shall not
exceed 0.6 times the permissible FAR.
(4) Regulations for flatted factories 21m and above in height
Front, Rear Permissibl Premium Minimum
Sl. Height of Extent of Plot
& Side e FAR FAR Road
No. the building in Sq.M
Setbacks(m) width(m)
1. 21m upto 2026-4050 7 1.75 1.0 18m
24 m Above 4050- 7 2.0 1.2 18m
8100
Above 8100- 8 2.25 1.35 Above 18m
12200
Above 12200 8 2.5 1.5 24m
2. 24 m upto Above 4050- 8 2.0 1.2 18m
27 m 8100
Above8100- 8 2.25 1.35 Above 18m
12200
Above 12200 9 2.5 1.5 24m
3. 27 m upto Above 4050- 9 2.0 1.2 18m
30m 8100
Above 8100- 9 2.25 1.35 Above 18m
12200
Above 12200 10 2.5 1.5 24m
4. Above 30m Above 4050- 10 2.25 1.35 Above 18m
upto 35m 8100
Above 8100- 10 2.5 1.5 24m
12200
Above 12200 11 2.5 1.5 Above 24m
5. Above 35m Above 4050- 11 2.25 1.35 Above18m
upto 40m 8100
Above 8100- 11 2.5 1.5 24m and
12200 above
Above 12200 12 2.5 1.5 30m
6. Above 40m Above 8100- 12 2.5 1.5 24m
upto 45m 12200
Above 12200- 12 2.5 1.5 Above 24m
20250
Above 20250 13 2.75 1.5 30.0m13
7. Above 45m Above 12200- 13 2.5 1.5 Above 24m
upto 50m 20250
Above 20250- 13 2.75 1.5 30m
32400
Above 32400 14 2.75 1.65 30m and
above
8. Above 50m Above 20250- 16 2.75 1.5 30m
32400
Above 32400- 16 2.75 1.65 30m and
40500 above
Above 40500 16 3.0 1.75 45m
Note:
1. Wherever TDR is permitted on a building site, then the maximum additional
FAR due to TDR and the Premium FAR together shall not exceed 0.6 times
the permissible FAR.
2. Where a plot faces a wide road other than the one prescribed against it, the
FAR shall be restricted only to the limit prescribed for the area of the plot;
3. When the plot does not face the road of required width noted against in the
table, then the FAR applicable to the corresponding road width shall apply.
1.5 Regulation for Industry linked Affordable Housing Projects in Industrial
Area (with dwelling units up to 60 Sq m)
I. Regulations for height below 21m.
Maximum
Setbacks Number of
Sl. Building Parking Height of the
floors
No Site size allowed building in
Front Rear Right Left permissible
meters
Upto 100
1
Sq.m
Any Road
1 0 0.6 0 Stilt Below 9 (Stilt+2)
width
Above 100
2 Sq.mupto
150 Sq.m
Any Road
1 0.6 0.5 0.5 Stilt Below 12 (Stilt +3)
width
Above 150
3 Sq.mupto
400 Sq.m
Road width
(i) below
1.2 1 0.75 0.75 Below 12 (Stilt +3)
9.0m
Stilt
(ii) 9.0m
2 1.5 1 1 Below 15 (Stilt +4)
and above
Above 400
4 Sq.mupto
1000 Sq.m
Road width14
(i) Below
2 1.5 1 1 Stilt Below 12 (Stilt +3)
9.0m
(ii) 9.0m
and upto 2.5 1.75 1.5 1.5
18.0m
(Stilt +4) or
(iii)Above Basement
Below 15 (Basement+
18.0m and 2.5 1.75 1.5 1.5 or stilt
Ground+3)
upto 30.0m
(iv) Above
3 2 1.75 1.75
30.0m
Above
1000
5
Sq.mupto
4000 Sq.m
Road width
(i) Below
3 2.5 2 2 Stilt Below 12 (Stilt +3)
9.0m
(ii) 9.0m (Stilt +4) or
Basement
and upto 3.5 3 2.5 2.5 Below 15.0 (Basement+
or stilt
18.0m Ground+3)
6 6 6 6 (Stilt +5) or
Basement
Below 18.0 (Basement+
or stilt
Ground+4)
(Stilt +6) or
Basement
6 6 6 6 Below 21.0 (Basement+
or stilt
Ground+5)
(iii)Above (Stilt +4) or
Basement
18.0m and 4 3 3 3 Below 15.0 (Basement+
or stilt
upto 30.0m Ground+3)
(Stilt +5) or
Basement
6 6 6 6 Below 18.0 (Basement+
or stilt
Ground+4)
(Stilt +6) or
Basement
6 6 6 6 Below 21.0 (Basement+
or stilt
Ground+5)
(Stilt +4) or
(iv) Above
4.5 4 4 4 Below 15.0 (Basement+
30.0m
Ground+3)
(Stilt +5) or
6 6 6 6 Below 18.0 (Basement+
Ground+4)
(Stilt +6) or
6 6 6 6 Below 21.0 (Basement+
Ground+5)
Above
6
4000 Sq.m
Road width
(i) Below
5 5 5 5 Stilt Below 15 (Stilt +4)
12.0m15
(Stilt +6) or
(ii) Above Basement
6 6 6 6 Below 21.0 (Basement+
12.0m or stilt
Ground+5)
Note:-
1. In case the building height exceeds 15.0 m, the minimum
setback/driveway shall be 6.0 m. The minimum 6.0 m setback/driveway
specified herein, or the setback mentioned in the table above, whichever
is greater shall apply.
2. Maximum Height of the building mentioned in the table above includes the
height of the stilt floor.
II. Regulations for height 21m and above.
Exterior set back to be left on all sides
Sl.no Height of building in mts
(front, rear and sides in m)
1 21.0 m up to 24.0 m 7.0
2 Above 24.0 m up to 27.0 m 8.0
3 Above 27.0 m up to 30.0 m 9.0
4 Above 30.0 m up to 35.0 m 10.0
5 Above 35.0 m up to 40.0 m 11.0
6 Above 40.0 m up to 45.0 m 12.0
7 Above 45.0 m up to 50.0 m 13.0
8 Above 50.0m upto 55.0m 16.0
9 Above 55.0m upto 70.0m 17.0
10 Above 70.0m upto 120.0m 18.0
11 Above 120.0m 20.0
1.6 PARKING REGULATIONS
(1) Parking norms for industrial buildings
a. Industrial (general)
One car parking of 2.5x5.5 m each shall be provided for every 250Sq .m of floor
area plus one lorry space measuring 3.5mx7.5m for every 2000Sq.m of floor area
and part thereof.
b. Industrial (flatted factories):
One car parking of 2.5x5.5 m each shall be provided for every 100sq .m of floor
area plus one lorry space measuring 3.5mx7.5m for every 5000Sq.m of floor area
and part thereof.
Note: If Plot size is less than 500 Sq.m than parking space for Lorry shall be
exempted.16
(2) Parking norms for Commercial buildings in Industrial Area
One car parking of 2.5x5.5 m each shall be provided for every 100sq .m of floor
area.
1.7 Protection Buffers for Electrical transmission lines/ Railway lines/ Water
bodies
a. Right- of -Way along electrical transmission lines: Buffer as Right-of-way
along electrical transmission lines of various Voltages shall be incorporated in
the Single Plot Layout/Layout /Sub-division plan as specified in the Table-
Buffer or as notified by the Competent Authority from time to time.
Table-Buffer
Park as Buffer on either side from the
Sl. No. Capacity of High-Tension line
centre of Tower in meters
1. 400 KV 26.00
2. 220 KV 17.50
3. 132 KV 13.50
4. 110 KV 11.00
5. 66 KV 9.00
6. 33KV 7.50
7. 11 KV 3.50
b. A butting Railway lines: A minimum of 30m wide strip from the boundary of
the railway property on either side, in case of both existing and proposed railway
lines. However, subject to the clearance or production of the No objection
Certificate (NOC) from the competent officer of the Railway Department, the
margin specified above may be relaxed to such extent as mentioned in the NOC.
Construction of Roads in the buffer strip shall be permitted.
c. Water bodies:
i. A minimum buffer from the outer boundary of the tank in case of plot adjoining
tanks as specified in the Karnataka Tank Conservation and Development
Authority Act, 2014 (Karnataka Act 32 of 2014);
ii. A minimum Buffer, around Nala /Halla as notified by the Government from time
to time;
iii. In case of industries, Health care establishments and infrastructure projects,
the distance from the water bodies shall be incompliance with the Government
Notification No: FEE 106 EPC 2021(i) Dated: 10.12.2021; and
iv. In case the buffer has not been marked due to cartographical error for any of
the above types of drains/nala, then based on the revenue records buffer shall
be insisted in all such cases without referring the land use plan while according
approval for building/development/ layout plan.
v. Under any circumstances area earmarked for drains (nala) cannot be converted
to any other uses.
vi. If the area adjoining drain/nala becomes a part of the layout/ development plan,
then that part of the valley zone could be taken into account for reservation ofR.N.I. No. KARBIL/2001/47147 POSTAL REGN. No. RNP/KA/BGS/2202/2017-19
Licensed to post without prepayment WPP No. 297
17
parks and opens paces both in layout/ development plan under subdivision
regulations.
vii. Provided that the additional area beyond the nala buffer, adjoining the primary
nala earmarked as parks, playground and open spaces shall be the designated
land use as per the approved Master Plan.
viii. Within the demarcated buffer for the valley the following infrastructure shall be
permitted within the buffer area along the water bodies like water pumping
stations, walking Tracks, play field without any construction, cycling tracks and
Parks.
1.8 Wherever the plot falls in the prohibited or restricted area or zone in the vicinity
of the Airport or Defence establishments or notified Archaeological Survey of India
monument or State archaeology monument or Coastal regulation zones and in such
other areas notified or as intimated by the Competent Authority, No Objection
Certificate shall be obtained from the respective Airport Authority of India,
Archaeological Survey of India /Department of Archaeology, Museums and Heritage,
Coastal Regulatory Authority or such other competent authority as the case may be.
By Order and in the name of the
Governor of Karnataka
(LATHA.K),
Under Secretary to Government
Urban Development Department
[