Clement Town Cantt Board

Issued by Ministry of Defence · Department of Defence

Read or download the official PDF of this gazette notification issued by the Ministry of Defence on 6th August 2026. Classified under Extra Ordinary.

Executive Summary & Key Takeaways

Executive Summary The document outlines the draft Clement Town Cantonment Building Bye-Laws, 2026, issued by the Ministry of Defence to regulate building construction, land use, and development within the Clement Town Cantonment. It establishes procedures for obtaining building sanctions via the e-Chhawani portal, defines zoning regulations (Zone I and Zone II), and mandates environmental sustainability measures like solar energy and rainwater harvesting. Stakeholders are invited to submit objections or suggestions to the Cantonment Board or via email (ceoclem-stats@nic.in) within 30 days from the date the Gazette copies are made available to the public.

Key Points / Main Content

Building Sanction Procedures

  • Digital Application: All applications for erection, re-erection, or alteration must be submitted through the e-Chhawani portal by a registered architect or engineer.
  • Eligibility: Only persons with legally valid occupancy rights (leased, old grant, or private land) may apply.
  • Fees: Applicants must pay building application fees and development charges; incentives/refunds are available for implementing rooftop solar and rainwater harvesting in certain categories.
  • Mandatory Notices: Applicants must provide a Notice of Commencement (Form D) before starting work and a Notice of Completion (Form E) within 30 days of finishing.

Zoning and Development Controls

  • Zone I: Includes civil areas and privately held land, typically characterized by higher population density.
  • Zone II: Covers all other land, including Old Grant Bungalows and leases outside the civil area, generally for low-density use.
  • Floor Space Index (FSI): Specific FSI limits are prescribed based on plot size and zone. For residential plots, FSI ranges from 1.10 to 1.80.
  • Height and Storeys: Minimum floor height is 2.70 metres; the maximum building height is capped at 11.50 metres. The maximum number of storeys permitted is G+2 or Stilt+3 (if stilt is used for parking).

Environmental and Safety Requirements

  • Sustainability: Rooftop solar installations and rainwater harvesting are mandatory for plots exceeding 200 square metres.
  • Landscaping: A minimum number of trees must be planted based on plot size (e.g., three trees for plots over 100 square metres).
  • Structural Safety: Construction must comply with the National Building Code and specific Indian Standards (IS) for earthquake resistance and fire safety.
  • Sanitation: Detailed requirements for septic tanks, including minimum dimensions (0.75m width, 1m depth) and specific distances from drinking water sources (18m).

Inclusive Design for Differently-Abled Persons

  • Access: Public buildings must feature ramps with non-slip surfaces and a maximum gradient of 1:20.
  • Facilities: Specific requirements for Braille signage, wide doorways (minimum 0.90m), and specialized toilet facilities.
  • Parking: Surface parking for two Equivalent Car Spaces (ECS) must be provided near entrances for differently-abled persons.

Impact Analysis

Applicants and Property Owners Impact: They are subject to modernized building codes, mandatory environmental installations, and a strictly digital application process. Action Required: Ensure all new constructions or alterations are registered on the e-Chhawani portal and comply with FSI, height, and sustainability mandates. Submit feedback on the draft within 30 days if desired.

Registered Architects and Engineers Impact: They bear increased responsibility for supervising construction and certifying that materials and designs meet the 2026 safety and structural standards. Action Required: Register on the e-Chhawani portal and ensure all submissions, including Form A (Safety Certificate) and Form B (Supervision Certificate), are technically accurate.

Cantonment Board and Competent Authority Impact: The Board gains a structured framework for digital oversight, zoning enforcement, and the power to revoke sanctions for misrepresentation or deviations. Action Required: Scrutinize digital applications within prescribed timelines and conduct inspections to issue Completion-cum-Occupancy Certificates.

General Public Impact: Residents are impacted by the standardized zoning and improved inclusive design in public spaces. Action Required: Review the draft Bye-Laws at the Cantonment Board office or website and submit any objections or suggestions to the CEO within the 30-day window.

Key Entities Referenced

Clement Town Cantonment Building Bye-Laws, 2026: The draft regulatory framework proposed to govern construction, sanctioning, and building standards within the Clement Town Cantonment. Cantonments Act, 2006: The primary legislation under which the building bye-laws are framed, specifically citing section 251 as the source of regulatory power. Cantonment Board, Clement Town: The local regulatory and administrative body responsible for implementing, sanctioning, and enforcing these building regulations. National Building Code of India: A comprehensive reference document used throughout the policy to define technical standards for structural safety, fire protection, and utility services. Clement Town: The specific geographic location that defines the territorial scope and applicability of these building bye-laws.
Official Gazette PDF Record Download Official PDF (Clement Town Cantt Board) →

Official Gazette Notification PDF Viewer

See Full Document Text & PDF Transcript
सी.जी.-डी.एल.-अ.-18082026-275538 CG-DxLx-xEG-I1D8H0x8x2x0 26-275538 xxxGIDExxx EXTRAORDINARY II— 4 PART II—Section 4 PUBLISHED BY AUTHORITY 43] 6, 2026/ 15, 1948 No. 43] NEW DELHI, THURSDAY, AUGUST 6, 2026/SHRAVAN 15, 1948 नई (cid:7408)द(cid:7016)ली, 6 अग(cid:7021)त ,2026 – (cid:401)ेम(cid:336)ट टाउन छावनी भवन उप- िविधयां, 2026 का िन(cid:635)िल(cid:304)खत (cid:366)ा(cid:349)प, िजसे छावनी बोड(cid:330), छावनी अिधिनयम, 2006 की धारा 251 (cid:554)ारा (cid:366)द(cid:517) श(cid:304)(cid:389)यो ं का (cid:366)योग करते (cid:352)ए और 7 अ(cid:366)ैल, 1945 की अिधसूचना सं(cid:421)ा23 //1G/O&L/45 को अिध(cid:354)िमत करते (cid:352)ए ,िसवाय उन काय(cid:344) के जो ऐसे अिध(cid:354)मण से पहले िकए गए या नही ं िकए गए ,जारी करने का (cid:366)(cid:721)ाव करता है; (cid:401)ेम(cid:336)ट टाउन छावनी भवन उप-िविधयां, 2026 का यह (cid:366)ा(cid:349)प, इससे (cid:366)भािवत होने की संभावना वाली जनता की जानकारी के िलए एत(cid:542)्वारा (cid:366)कािशत िकया जाता है ;साथ ही, यह सूचना दी जाती है िक उ(cid:389) (cid:366)ा(cid:349)प उप-िविधयो ं पर उस तारीख से तीस िदनो ं की अविध समा(cid:593) होने के बाद पर या उसके प(cid:686)ात् िवचार िकया जाएगा, िजस तारीख को इन उप-िविधयो ं को अंतिव(cid:330)(cid:700) करने वाली भारत के राजप(cid:361) की (cid:366)ितयां जनता के िलए उपल(cid:617) कराई जाती ह(cid:339) ;और उ(cid:389) (cid:366)ा(cid:349)प उप-िविधयां, छावनी बोड(cid:330), (cid:401)ेम(cid:336)ट टाउन के काया(cid:330)लय म(cid:336) और वेबसाइट https://clementtown.cantt.gov.in पर भी उपल(cid:617) ह(cid:339)। कोई भी (cid:681)(cid:304)(cid:389) जो (cid:366)ा(cid:349)प उप-िविधयो ं म(cid:336) अंतिव(cid:330)(cid:700) (cid:366)(cid:721)ावो ं पर कोई आपि(cid:517) या सुझाव देना चाहता है, वह छावनी बोड(cid:330) के िवचाराथ(cid:330), िविनिद(cid:330)(cid:700) अविध के भीतर, छावनी बोड(cid:330), (cid:401)ेम(cid:336)ट टाउन को या ईमेल पते : ceoclem- stats@nic.in पर िल(cid:304)खत (cid:349)प म(cid:336) भेज सकता है। 6069 GI 20262 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] - , 2026 1 1. , :— (1) - - , 2026 (2) , (3) - , 2. :— - , : (1) “ ” ( ) ; (2) “ ” ( ) , , , , (3) " " , 2006 , - ; (4) " " (cubic) ; (5) “ ” , , , ; , , , , , , , (6) “ - ” , , , - ; (7) " " - ( ) - , ( ) , ( ) ; (8) , “ ” ( ) , , , , , , , , , , , ,[ II— 4] 3 , , , - , , - , ATM, , , , ( ), ( ), , , , , , (9) “ ” (dwelling unit) — , , (dwelling unit), , , , , , , , , — (immovable property) , ( , , , ) , , , (10) “ ” - (11) " " , / / ; (12) " " , - ; (13) " " (Approved) , ; (14) " " (Architect) , , 1972 , (Council of Architecture, India) ; (15) “ ” , , - (16) " " (Atrium) , / , (17) " " (projection) , , ;4 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] (18) " - " (Barrier free) - ; (19) " " , (20) " " (Basement) , - , - ; (21) " " , 2006 ; (22) " " , (outhouse), , , , — , , , , — ; - (boundary wall) , ; (23) " " , ; - ( ) ; (24) “ ” , , - ; , , ; , , , , , ; , ; (25) " " , , , ( ) ; ( ) ; (26) " - " , ( ) , (F.S.I) (27) " " , ' ' ( )[ II— 4] 5 (28) " " ( ) ; (29) " " (non-load bearing) (non-masonry) (30) “ ” (Canopy) , , , , : ; (31) “ ” (Ceiling Height) ( ) ; (32) - “ ” (Central Government)— , ; (33) " " (horizontal) (34) “ ” (Chimney) (shaft) , (flues) ; (35) “ ” (Civil Area) , 46 - (1) ; (36) “ ” (Civil Engineer) , , , ‘ ( )’ , ; (37) “ ” (Combustible Material) , , ( ) — - (good practice) — ; (38) “ ” (Commercial Building) , , ;6 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] (39) “ ” (Competent Authority) , 2006 10 ; (40) “ ” (Corner Plot or Site) , - ; (41) “ ” (Courtyard) , , (Ground Floor) ; (42) " " (Covered Area) , , : ( ) , , , , , ( ), , , , , ; ( ) , (culvert), (conduit), , , , , , , ; ( ) , , , , , ; (43) “ ” (Cupboard) , 0.75 (partitions) ; (44) " " (Damp Proof Course) , ; (45) " " (Demolished) ; (46) " " (Drain) , — , , , , , (yards) , (cartilage) ;[ II— 4] 7 (47) “ ” (Drainage) , , ; (48) " / " (Dwelling unit/ Tenement) , , - - ; (49) " " ; (50) " (ECS)" (Equivalent Car Space) , , " " (National Building Code) ; (51) " " (Existing Building or Use) , , , (Competent Authority) , - (Bye-Laws) ; (52) " " (Exit) , , , , , ; ( ) : , , ; ( ) : ; ( ) : ; (53) " " , , , ; (54) " " , " " , / ,8 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] 1, 2 , ; (55) " " "FAR" , : FAR = x 100 (56) " " "FSI" , : FSI = (57) " " , , ; (58) “ ” , (bearing area) ; (59) " " (Foundation) , (super structure) ; (60) " " ; (61) " / / " , / / , , , (62) " " , , ; (63) " " (Garage Private) ; (64) " " , , : = x 100[ II— 4] 9 (65) " " , ; (66) " " , , , , ; (67) " " , , , , , , , , , , ; (68) " " / ; (69) " " , , 100 ; ; (70) " " , 1.50 ; (71) " / " - - ; (72) " " , , , , , - ; (73) " " ; (74) " " , / ;10 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] (75) " " , ; (76) " " , ; (77) " " (Occupancy) ; (78) " " (Parapet) , 1.00 ; (79) " " (Parking Space) , , - ( ) , - ( ) ; (80) " " (Partition) , - (non-load bearing) , ; (81) " " (Pavilion) , , , , , , , , , , , , ; (82) " " (Pillar) , , , , , ( ) , ; (83) " " (Plinth) - ; (84) " " (Porch or Portico) , ; (85) " " (Public Building) , - , , , , , / , , , , , , , , , ; (86) " " (Public Garage) , ,[ II— 4] 11 , , , , ; (87) " " (Repairs) , - (Bye-Laws) , ; ( ) , , , (i) (partition wall), , (ii) (parapet wall), (cornice) , (setbacks) (ground coverage area) 1.00 1.50 ; ( ) ; ( ) ; ( ) (Re-flooring); ( ) - , ; ( ) - , ; ( ) ( ); ( ) , , ; ( ) ; ( ) , ; ( ) ( ) ; ( ) / / / ; (88) " " (Residential Building) , ; (89) " - - " (Residential cum Commercial Building) ,12 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] , , ; (90) “ ” , , 2006 235 , - , , 2006 234/237/238 ; (91) “ ” (center line) , ; ; (92) " " ; (93) “ ” (horizontal) (flue) , ; (94) " " ; (95) “ ” ; , ; (96) " " (Cantonment) , , , , , — , — ; , ( ) ; (97) " " (graduate) — — ' ( )' , , ; (98) " " (Sun shade) , (overhang) , (openings) , ; (99) " " ( ) -[ II— 4] 13 , , (100) " " (To Abut) , , , , ; (101) " " (To erect or Re-erect) : ( ) , ; ( ) , , , , , , , ; ; ( ) ; ( ) ; ( ) ; (102) “ ” , , ; (103) “ ” ; (104) “ ” ; (105) " " (Warehouse) , ( ) ; ; (106) " " / ; (107) " " ( ) , ; (108) " " , , (i) " " (ii) " "14 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] (109) " " ( ) , , - ; (110) " " , , ; (111) - , , ; 2 3. — , , , , (Competent Authority) 4. .—(1) , , e-Chhawani ; (Plans) , e-Chhawani (Architect) (2) (Leased) , (Old Grant) (Occupancy Rights) , , , , , / , (3) , ( , ) (4) ( , ) , - ( ) 5. .—(1) : ,[ II— 4] 15 (2) : , ( ) , (3) (Rooftop Solar Installation) (Rain Water Harvesting) , : 200 , , , / , / , ( ) (Resolution) (4) (Stacking) , ; 257 6. .— , ' - ' (e-Chhawani) : (i) / HOR ( ) / / / ; (ii) (Affidavit) (Indemnity Bond); (iii) (iv) ( - ) 7. / , .—(1) ' ' (Old Grant) , ' ' (2) (Leased) , - / (3) , , :-16 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] (i) , , , - , - (elevation), (section) - ; (ii) , - ; (iii) - ; (iv) , 260 - , 348 (19) (20) - ; (v) , ; (vi) , ; (vii) , 240 ; (viii) , , ; , , ; (ix) , , , , ; (x) / 50.00 / 15.00 ; (xi) 200 , (Rain Water Harvesting) ; (4) , ,[ II— 4] 17 (5) , , (revalidation fees) (revalidate) , : ( ) (plan) ( ) , - ( ) ( ), ( ) / / , , [ / 50.00 15.00 ; , 50.00 15.00 (authorized) ] 8. (SCRUTINY).— , ; , , 9. - .—(1) - , , , , / / ( ); , (deviation) (2) - , (Competent Authority) / (3) ,18 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] 10. .—(1) , , (2) , , / ; 11. - - .— , , , ; 12. (Composition).—(1) / (2) , , 2006 , - ; , - , (3) - , , (Compounding) , ( ) , ; ( ) , - 3 13. .—(1) , .— ( ) 1.— ( ) 2.— 1 , ( ) (leases)[ II— 4] 19 (2) -1.— , ( ) .— , , , ( ) ` .— , : : 1 ( / ) . . ( ) 1 50-150 1.80 2 151-250 1.70 3 251-350 1.60 4 351-450 1.50 5 451-550 1.40 6 551-750 1.30 7 751-1000 1.20 8 1000 1.10 : 1 ( ) . . ( ) 1 15-100 1.50 2 101-200 1.50 3 201-500 1.50 4 501-2000 2.00 5 2001-2500 2.00 6 2500 2.2020 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] ( ) (Tenement Density): 50 , 10 ( ) .— 2.70 , , ; , 11.50 ( ) , ( ) .— -1 G+2/Stilt+3 , [ +2/ +3 , +2/ +3 ] (3) -2.— , ( ) ( ) .— , , , ( ) : , FSI : : 2 ( / ) . . ( ) 1 50-150 1.80 2 151-250 1.70 3 251-350 1.60 4 351-450 1.50 5 451-550 1.40 6 551-750 1.30[ II— 4] 21 7 751-1000 1.20 8 1000 1.10 : 2 ( ) . . ( ) 1 15-100 1.50 2 101-200 1.50 3 201-500 1.50 4 501-2000 2.00 5 2001-2500 2.00 6 2500 2.20 : 2 ( ) . . ( ) 1 / 400.00 / 2000.00 1.00 2 / / 4000.00 / 15000.00 / 1.60 15000.00 3 20000.00 2.11 4 / 300.00 1.80 5 750.00 1.50 / / 6 50 2000.00 1.50 7 51 200 5000.00 2.00 ( ) (TENEMENT DENSITY).— 50 , 10 ( ) (BUILDING HEIGHT).— -2 2.70 ; (22 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] ) , , 11.50 , ( ) (MAXIMUM NUMBER OF STOREYS PERMISSIBLE).— -2 G+2 / Stilt+3 , 4 14. / - (OPEN SPACES/SET BACKS).— (building envelop) - : - (1) - (FRONT SETBACK) ( ) , (front property line) ' - ' ( ) (front elevation) ' - ' ( ) , ' - ' , ( ) , 5.00 , - (2) - (SIDE AND REAR SETBACK) ( ) , - (Bye-Laws) ' - ' , (rain water harvesting) , - (soak pit) ; 5.00 , ( )[ II— 4] 23 ( ) , : : ( ) . . ( ) ( (1) (2) ) 1 50-75 1.20 -- -- -- 2 76-150 2.00 1.50 -- -- 3 151-300 3.00 2.00 -- -- 4 301-500 4.50 3.00 1.50 -- 5 501-750 5.50 3.50 3.00 2.00 6 751-1000 6.50 4.00 3.50 3.00 7 1000 7.50 4.00 4.00 4.00 : ( ) . . ( ) ( (1) (2) ) 1 200 4.50 -- -- -- 2 201-400 6.00 2.00 3.00 -- 3 401-600 7.50 3.00 3.00 -- 4 601-1000 8.00 3.00 4.00 1.50 5 1001-1500 9.00 4.00 4.50 3.00 6 1501-3000 10.00 5.00 4.50 4.50 7 3000 12.00 6.00 6.00 6.0024 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] : ( ) . . ( ) ( ) (1) (2) 1 1000 6.00 4.50 3.60 3.60 2 1001-3000 7.50 4.50 4.50 4.50 3 3001-8000 9.00 6.00 4.50 4.50 4 8001-15000 12.00 6.00 6.00 6.00 5 15001-35000 15.00 6.00 6.00 6.00 6 35000 18.00 6.00 6.00 6.00 , : (i) 75 , , 1.20 (ii) 76.00 1000 , 2.00 1.50 (iii) (3) - .— ( ) ( ) , , , ( ) , : : . . (dimension) ( ) ( ) 1 6.00 1.20 0.90 2 6.00 2.80 1.30 15. .— , NOC ( )[ II— 4] 25 16. - .— - , - , ' ' (no-objection) 17. .—(1) - ' ' ( 10.3 3) , - , , , , (2) 18. .— - , 0.30 19. .— - 0.30 - 20. .—(1) 9.50 (2) 2.40 (3) , 9.50 7.50 , 2.10 21. .—(1) , ( ) , 2.70 (2) ( - ) , , , 3.00 (3) (pitched roof) , 3.90 , (eaves) (clear headroom) 2.4026 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] 22. - ( ).—(1) : 1.80 , 1.20 - 1.10 , 0.90 - 2.80 , 1.20 (2) : - , ( ) , 2.10 (3) : - : ( ) , 0.30 ; ( ) - , , , ( - ) ; ( ) / ; ( ) / (partitions) , 0.45 , ; ( ) , , (4) - , (lavatory) ; , , ( ) , 23. (KITCHEN).—(1) : 5.00 1.80 ( ) , 7.50 2.10 (2) : , ( ) , 2.75 (3) : :[ II— 4] 27 ( ) 2.75 ; ( ) , - 31.4 , (shaft) ; ( ) , , , (waste pipe) ; ( ) / (partitions) , 2.75 - (impervious) ; ( ) - , , :- [GAIL ( ) ] 24. (PANTRIES).— : (1) 3.00 1.50 ; (2) , ; (3) / , 2.75 - ; (4) - , , 25. .—(1) 1.50 (2) (headroom) 2.20 , (3) , 2.00 ;28 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] 26. .—(1) : , (built-up area) 33 (2) : 2.2 (headroom) 2.2 (3) : , : ( ) , ; , , ( ) 9.5 , - , ( ) - ; ( ) ( ) 27. .—(1) : 2.75 x 5.00 , 2.00 (2) / : - 17 (3) : ( ) 2.4 (4) - 0.30 (5) / , - (6) : , ( )[ II— 4] 29 , , , ( ) 28. .—(1) ; , , - (2) , , 9 1: , , - (3) , , (4) 29. .—(1) , (2) ; , 1 ( ) , : ( ) ( ); ( ) , ; ( ) - ; ( ) (3) , :- ( ) , , 2.70 ( ) - - , ; 5030 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] ( ) , - 0.90 1.20 ( ) ( ) (partitions) ( ) , ; 10.00 ( ) R.C.C. , ( ) ( ) , / (thimbles) 50.00 (fire extinguisher) ( ) - (water-tight) - , , ( ) , ( ) , ( ) , , ( ) ( ) 1.00 ( ) , , ( ) - , - , (enclosed) ,[ II— 4] 31 (building line) , , ( ) ( ) , ' ' , 30. (CHIMNEYS).—(1) , I.S. 1645-1960 ( - , , ) (2) 0.90 ; , - (parapet) , (ridge) 0.60 , 31. .—(1) , , , 1.00 , 6.00 , 6.00 , 1 0.10 , 3.00 , (2) , ' ' ( - ) VIII - , 1 - , ' ' - , ' ' (3) (glazing) , , 15% (4) , , 5%32 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] (5) , (opening) 4.00 (6) , (attached toilets) , (mechanical ventilation system) ' ' ( - ) VIII , ' ' 32. .— , 0.90 1.00 , 33. .—(1) , , 2006 261 , , ; 2.50 34. .—(1) : ( ) , ( ) , ; , ( ) ( ) (exits) , , ( ) , ( ) ( ) ; , ( ) , ( )[ II— 4] 33 ( ) (occupied unit) , (2) .—( ) (horizontal) (vertical) , , , , , , , ( ) ; ( ) , (3) : , , (occupant load), , ( ) : , , 22.50 , , , , 30 , - , , , 6.00 ( ) : ' ' ( ) - ' ' ( ) : ( ) , 0.50 , ' ' , - (4) .—( ) , , , ( ) 1.0 2.10 , , 0.7534 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] ( ) , ; , , 1.20 ( ) , ( ) ( ) ( ) (Revolving doors) (5) .—( ) , , , , , , , ; , , , , , 500 , 12 , , , ( ) ; ( ) , ; ( ) 1.0 ( ) ( ) 250 , (tread) 300 ( ) , (riser) 190 150 ( ) 12 ( ) ( ) , 0.90[ II— 4] 35 ( ) (passage) (headroom) 2.10 headroom ( ) , (stairwell) ( ) , (draught lobby) ( ) (fire escape) ( ) , AC ( ) ( ) ( ) ( ) ( ) (escape route) ' ' (exit signs) , (flushed) - , ' ' , 0.50 X 0.50 ( ) , , , , - - , (enclosures) (6) .—( ) (evacuation time) , (Fire escapes)36 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] ( ) ( ) ( ) ; - (fire resistance) ( ) (non-combustible materials) ( ) , 1.20 ; (treads) 280 (risers) 190 (risers) 16 ( ) (Handrails) 1.00 (7) .—( ) 1:10 1:12 ( ), ; - (enclosure) - (limiting dimensions) (non-slipping materials) ( ) 2.50 ( ) (Handrails) ( ) , (8) (Corridors) .—( ) 3 (row housing) , 1.0 , 2.0 ( ) , , , ' ' (smoke stop door) 35. .— : ( ) (terrace) , , , , ( 2.0 )[ II— 4] 37 ( 2.50 ) ( ) , , ( ) , , ( ) ( ) , ( ) , ( ) ( ) ( ) , 2.50 5 36. .— , (1) .— , / , ( ) - 1.0 1.20 (2) / .— 1.50 , , 1:20 ( ), - , - ( ) ,38 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] (3) .— , : ( ) 30 , ' ' (ECS) ( ) ( ) 2.80 ( ) , ( ) , , (4) .— : ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) (5) .—( ) , 1.50 (gradient) 1:20 12.0 , 0.90 (handrail) , 300 40 ( ) 1.00 (threshold) 300 ( ) , (tread) 300 (riser) 150 , , 0.90 (6) / .— / ,[ II— 4] 39 , : ( ) , ( ) 1.5 ( ) , 1:20 (slope way) ( ) / (7) .— (8) .— , , ' ' 13 ( ) 1.10 ( ) 2.0 0.90 ( ) , 1.0 , 0.60 ( ) 1.80 x 2.00 ( ) ( ) ' ' , - (9) .— (WC) - , - ( ) 1.370 x 1.75 ( ) 0.80 ( ) 40 , / ( ) 0.50 (10) ( ).— / , -40 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] , ( ) , , ( ) 900 ( ) 900 1200 ( ) 10 6 , , , 37. .—(1) , , : : ( ) 1 100 30 ; 50% , 4.00 2 100 - 20.00 ; 200 50% , 4.00 3 200 15 ; 50% , 4.00 (2) (3) : (a) 100 (b) 5.00[ II— 4] 41 38. .— , , , , - , , 2005 -VI , -1 , 2 - , 3 - , 4 - , 5 - , 6 - ; : (1) IS: 1893 ( 1)-2002 " - ( )" (2) IS: 13920 - 1993 " - " 1993. (3) IS: 13828 - 1993 " - " 1993. (4) IS: 4326-2013 " - - ( )" (5) IS: 13827 - 1993 " - " 1993. (6) IS: 13935-2009 " , - " (7) : ( ) IS 14458 ( 1): 1998 (retaining wall) : 1 . ( ) IS 14458 ( 2): 1997 ( ) : 2 / ( ) IS 14458 ( 3): 1998 : 3 ( ) IS 14496 ( 2): 1998 - : 2 - (8) (National Building Code) , 39. — (1) ( ) , ,42 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] ; V ' ' VII ' ' ( ) , , ' ' ( ) - , , , , - , (2) ( ) - , - 39.1 ; BIS ( ) , , ; , , , , , , , , - 40. .— , , , ' ' VIII ( ), - 2 ( ), - 3 ( - ), - 5 ( ) 41. .—(1) : ( ) , , , , , ( ) ( ) , , (CFL), LED ( ) , / , , LED[ II— 4] 43 (2) , (solar water heating systems) : ( ) , ; (load bearing capacity) 152.90 ( ) ( ) , ( ) 150 , 5% ( ) - BIS IS 12933 BIS (3) , - (4) , - : ( ) ; ( ) ; ( ) , , , ; ( ) , 100 ; ( ) 15 ; ( ) 500 ; ( ) ; (5) - - .— 200 , , - ; -44 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] 42. (Lightning Protection).— ' ' III 43. .— , , , , ' ' IX ( ), - 1 ( ), - 2 ( ), - 3 ( ) 44. .—(1) , , - ( ) : ( ) : (2) : , : : 1 1 2 2 500 3 1 4 2 500 : 1. , , 2. , - - - : 70 - : 135 - : 200[ II— 4] 45 45. .—(1) 100 , (2) / / / / , 200 (3) - - (4) , , , , (5) / , , (6) , , 46. .—(1) , 200 ; - - : ( ) ( ) 10 ' ' ( ) ( ) ( ) / (recycled) , / - (discharge) 10 (2) , - ' ' (National Building Code) 47. : , , NBC ' 9 - , 1 - , ( )'46 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] (1) - : , ( - ) , , 18 , ( ) , 6 (2) : ( ) - 0.75 , 1 1 (1m3) 2 4 ; ( ) , , ; ( ) ( ) ( ) ; ( ) 100 , , 45° ; ( ) , - 1:300 1:400 ; ( ) 50 , 2 , 15 , 15 2 ; ( ) , , 0.90 1.00 , , 75 ,[ II— 4] 47 , , 0.90 ; ( ) (effluent) ( ) , 0.50 1.00 0.30 1.00 150 250 - (un-glazed earthenware) 75 100 30 1.80 7 , 48. (Savings Clause).— , - (Bye-laws) 49. .— - , 50. - : NOC - 51. ' ', .— , ' - ' , ' , 2006' - , - - , (lease) , ' ' (old grant) , - ; ' - ' , , -48 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] : ( e-Chhawani ) , / , / ____________, /GLRS ______________ _____________ ________________ / , ______________ / / - , , / (additions/alterations) , , , , , , , - ____________________ ____________________ ____________________ ____________________ ____________________ ____________________ ____________________ ____________________ ____________________ ____________________ ____________[ II— 4] 49 : (Supervision) ( / / e-Chhawani ) , / , _______________ ( ____________________, _______________, / ____________, / GLRS ______________ ) / / ( ) , (general specifications) , (sanctioned plan) (execution) / / ____________________ / / ____________________ / / ____________________ / / ____________________ ____________________ ____________________ ____________________ ____________________ ____________________ ____________50 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] : (Indemnity Bond) ( e-Chhawani ) - (Non-Judicial) , / _________________ ______________ _______________ ( ) , _________________ ________ , , , , , ; , — , , - / / , , , ; , , ( ) / , , , ___________ , ( ) (1) _______________________ ( ) (2) _______________________ : (1) _______________ (2) _______________ _______________[ II— 4] 51 : , / , _____________, _______________ / / ____________ ____________ __________ , _____________ / / __________________ __________________ ( ) __________________ ______________ ____ ______________ ____ ________________52 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] : ( 242) , / , 1. ________________ ( ) / , / _________________ __________ - (byelaws) , (specifications) / / - - , , / , / 2. - : / , IS / / (water harvesting) (waste water recycling) , (drawings) 3. 4. ( ) ______________________________ ______________________________ ______________________________ ______________________________ ______________________________ ______________________________ ______________________________ ______________________________ ______________________________ ______________________________ ______________________________ ______________________________[ II— 4] 53 : - - ( 246) , __________________ __________________ __________________ __________________ / , _____________________ , ________________________ ( ) — _________________ _____________ — , , - ( ) : : 1. ____________________________________ 2. ____________________________________ 3. ____________________________________ 4. ____________________________________ 5. ____________________________________ 6. ____________________________________ 7. ____________________________________ 8. ____________________________________ 9. ____________________________________ 10. ____________________________________ 11. ____________________________________ 12. ____________________________________ _______________ _______________54 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC.4] MINISTRY OF DEFENCE NOTIFICATION New Delhi, the 6th August, 2026 S.R.O. 43 (E). – The The following draft of the Clement Town Cantonment Building Bye-Laws, 2026, which the Cantonment Board proposes to issue, in exercise of the powers conferred by section 251 of the Cantonments Act, 2006 and in supersession of notification number 23/1/G/O&L/45 dated 7th April, 1945, except as respects things done or omitted to be done before such supersession, the draft Clement Town Cantonment Building Bye-Laws, 2026 is hereby published for the information of the public likely to be affected thereby, and notice is hereby given that the said draft Bye-Laws shall be taken into consideration on or after the expiry of a period of thirty days from the date on which copies of the Gazette of India containing the Bye-Laws are made available to the Public; and the said draft Bye-Laws are also available at the office of the Cantonment Board, Clement Town and on the website https://clementtown.cantt.gov.in. Any person interested in making any objections or suggestions on the proposals contained in the draft Bye-Laws may forward the same in writing, for consideration of the Cantonment Board within the period so specified to the Cantonment Board or at e-mail address : ceoclem-stats@nic.in. The Draft of the Clement Town Cantonment Building Bye-Laws, 2026 CHAPTER I GENERAL 1. SHORT TITLE, EXTENT AND COMMENCEMENT:(1) These Bye-Laws shall be called the Clement Town Cantonment Building Bye - Laws, 2026. (2) These shall come into force on the date of final publication in the Official Gazette by the Central Government. (3) These Bye-Laws shall apply within the limits of Clement Town Cantonment. 2 DEFINITIONS: In these Bye-Laws, unless the context otherwise requires: (1) “Access” means a clear approach to a plot or a building; (2) “Accessory Building” means a building separate from the main building on a plot and containing one or more rooms for accessory use such as servant quarters, garage, storerooms etc. (3) “Act” means The Cantonments Act, 2006 as amended from time to time; (4) "Addition to a building" means addition to the cubic contents of a building; (5) “Advertising Sign” means any surface or structure with characters, letters or illustrations applied thereto and displayed outdoor in any manner whatsoever for purpose of advertising or to give information regarding or to attract the public to any place for public performance, article or merchandise whatsoever, or is attached to, or forms a part of building, or in connected with any building or is fixed to a tree or to the ground or to any pole, screen, fence or hording or displayed in space, or in or over any water body. (6) “Air-Conditioning” means the process of treating air so as to control simultaneously its temperature, humidity, cleanliness and distribution to meet the requirement of conditioned space; (7) "Alteration of a building" means-[ II— 4] 55 (a) The sub-division of any room in such building so as to convert the same into two or more separate rooms, or; (b) The change in two or more rooms in such building which increases or diminishes the cubic content of any room or rooms, or; (c) The conversion of any passage or space in such building into a room or rooms; (8) “Amenity Space” means for the purpose of these regulations, amenity space means a statutory space kept in any layout to be used for any of the amenity such as open spaces, parks recreational grounds, playground, sport complex, gardens convenience shopping, parking lots, primary and secondary schools, nursery, health club, dispensary, Nursing home, hospital, sub post-office, police station, electric substation, ATM of banks, electronic cyber library, open market, garbage bin, assisted living and hospice together, senior citizen housing and orphanage together, project affected person, housing, auditorium, conventional Centre, water supply, electricity supply and includes other utilities, services and conveniences. (9) “Apartment” means whether called block, chamber, dwelling unit, flat, office, showroom, shop, godown, premises, suit, tenement, unit or by any other name, means separate and self-contained part of any immovable property, including one or more rooms or enclosed spaces, located on one or more floors or any part thereof, in a building or on a plot of land, used or intended to be used for any residential or commercial use such as residence, office, shop, showroom or godown or for carrying on any business, occupation, profession or trade, or for any other type of use ancillary to purpose specified; (10) “Appendix” means an appendix to these Bye-Laws; (11) "Applicant" means a person who has legally valid occupancy rights on leased or old grant or private land and intends to erect/re-erect a building or to make any addition/alteration in the building; (12) “Application” means an application made in such a form as may be specified by the authority from time to time; (13) "Approved" means approval granted by the Competent Authority as prescribed under the Act; (14) "Architect" means any person who holds a valid registration with the Council of Architecture, India as per the provisions of the Architects Act, 1972; (15) “Architectural Projection” means a chhajja, cornice etc. which is a protrusion from the building façade or line of the building only for aesthetic purpose and not used for any habitable purpose. (16) "Atrium" means a sky lighted and naturally/mechanically ventilated area in a building with no intermediate floors and used as circulation space or entrance foyer; (17) "Balcony" means a horizontal projection including a hand rail, balustrade or a parapet to serve as a sitting out place; (18) "Barrier free" means a barrier free environment which enables people with disabilities to move safely and freely and to use the facilities within the built environment; (19) "Barsati" means a shed or covered space, which is not enclosed on all sides, used for shelter on the roof or a building; (20) "Basement" means the lowest storey of a building below or partly below ground level or adjoining ground level; (21) "Board" shall mean a Cantonment Board constituted under The Cantonments Act, 2006;56 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] (22) "Building" means a house, outhouse, stable, latrine, shed, hut or other roofed structure whether of masonry, brick, wood, mud, metal or other material, and any part thereof and includes a well and a wall other than a boundary wall but does not include a tent or other portable and temporary shelter; (23) "Building Envelope" means the horizontal spatial limits up to which a building may be permitted to be constructed on a plot which shall not exceed the clear setbacks as prescribed in the Bye-Laws; (24) "Building Height" means the vertical distance measured in the case of flat roof from the average level of the centre line of the adjoining street to the highest points of the building adjacent to the street wall; in the case of pitched roofs up to the point where the external surface of the outer wall intersects the finished surface of the sloping roof; and in the case of gable facing the road, the midpoint between the eaves level and the ridge. Architectural features, chimneys, water tanks and other ornamental features which are not intended for human habitation and serving no other function except that of decoration shall be excluded for the purpose of taking heights, and if the building does not abut on a street the height shall be measured above the average level of the ground around and contiguous to the building; (25) "Building Line" means the line up to which the plinth of a building adjoining on a street or on an extension of a street or on a future street may lawfully extend and includes the line prescribed, if any, in any scheme; (26) "Built up Area" means the area covered by a building on all floors including cantilevered portion, mezzanine floors, if any, but excluding the areas specifically exempted from computation of Floor Space Index (F.S.I) under these Regulation; (27) "Bungalow Area" means area outside notified civil area with old grant / leasehold Bungalows; (28) "Butchery" means a slaughterhouse where animals (sheep and goats) are slaughtered under the supervision of competent Authority; (29) "Cabin" means a non-residential enclosure constructed of non-load bearing, non-masonry partitions; (30) "Canopy" means an overhead roof or else a structure over which a fabric or metal covering is attached, able to provide shade or shelter from weather conditions such as the Sun, hail, snow and rain. A canopy can also be a tent, generally without a floor; (31) "Ceiling Height" means vertical distance between the finished floor and the ceiling; (32) "Central Government" for the purposes of these Bye-Laws means the Government of the Union through the Ministry of Defence; (33) "Chajja" means a sloping or horizontal structural overhang usually provided over openings on external walls to provide protection from sun and rain and for purpose of architectural appearance; (34) "Chimney" means an upright shaft containing and encasing one or more flues; (35) “Civil Area” means an area declared to be a civil area by the Central Government under Sub-Section (1) of Section 46 of the Act; (36) "Civil Engineer” means any person who is a graduate of civil engineering from a recognized Indian or foreign university duly approved by Govt. of India or is a member of Civil Engineering Division of the Institution of Engineers (India) and is competent to carry out supervision of building works as per approved drawings and design; (37) "Combustible Material" means any material if it burns or adds heat to a fire when tested for combustibility in accordance with good practice; (38) "Commercial Building" means a building used or constructed or adapted to be used the whole or a substantial part of building for commercial purposes;[ II— 4] 57 (39) "Competent Authority" means the authority to sanction the building plan as prescribed under Chapter X of the Cantonments Act, 2006; (40) "Corner Plot or Site" means a plot or site at the junction of and fronting on two or more intersecting streets; (41) "Courtyard" means a space open to the sky enclosed or partially enclosed, by walls or by railing and shall be at ground floor level; (42) "Covered Area" means ground area covered by the building immediately above plinth level, but does not include the space covered by the following: (a) Garden, rockery, well and well structure, plant nursery, water pool, swimming pool (if uncovered), platform around a tree, water tank, fountain, bench with open top and unenclosed sides and the like; (b) Drainage, culvert, conduit, catch pit, gully pit, chamber, gutter, septic tank, soakage pit and the like; (c) Compound wall, gate, canopy, uncovered staircase areas covered by sunshade and the like; (43) "Cupboard" means a space used for storage of household goods / dress having shelves / partitions not more than 0.75-metre apart; (44) "Damp Proof Course" means a course consisting of appropriate water proofing material provided to prevent penetration of dampness or moisture from any part of the ground to the structure or from one part of the structure to any other part of it; (45) "Demolished" means total dismantling of an existing building; (46) "Drain" means a line of pipes including all fittings and equipment such as manholes, inspection chambers, traps, gully traps and floor traps, used for the drainage of a building, or a number of buildings, or yards appurtenant to buildings, within the same cartilage. Drain shall also include open channels used for conveying surface water; (47) "Drainage" means the removal of any liquid by a system constructed for this purpose; (48) "Dwelling Unit / Tenement" means an independent housing unit with separate facilities for living, cooking and sanitation needs; (49) "Enclosed Staircase" means a staircase separated by fire resistant walls and doors from the rest of the buildings; (50) "Equivalent Car Space (ECS)" means the space occupied by the vehicle as well as the minimum space needed to move it into and out of the space and one equivalent car space is as defined in National Building Code, as amended from time to time; (51) "Existing Building or Use" means a building, structure or its use as sanctioned or deemed to have been sanctioned by the Competent Authority, existing before the commencement of the Bye-Laws; (52) "Exit" means a passage, or means of egress from any building, storey or floor area to a street or any other open space of safety: (a) Vertical exit: It is a means of exit used for ascending or descending between two or more levels including stairways, ramps and fire escapes; (b) Horizontal exit: It is a protected opening through or around a fire-resistant wall or bridge connecting two buildings; (c) Outside exit: It is an exit from the building to a public way or to an open area leading to a58 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] public way or an enclosed fire-resistant passage leading to a public way; (53) "External Wall" means an outer wall of a building not being a partition wall, even though adjoining to a wall of another building and also means, a wall abutting on an interior open space of any building; (54) "Floor" means the lower surface in a storey on which one normally walks in a building. The general term, floor, unless otherwise specifically mentioned, shall not refer to a mezzanine floor. Sequential numbering of floor shall be determined by its relation to the determining entrance level. For floors at or wholly above ground level the lowest floor in the building with direct entrance from the road/street to be termed as Ground Floor. Other floors above ground floor shall be numbered in sequence as Floor 1, Floor 2, with numbers increasing upwards; (55) "Floor Area Ratio" or "FAR" means the quotient obtained by dividing the multiple of the total of the covered area on all floors and hundred by the area of the plot i.e. FAR = Total covered area of all floors X 100 Plot Area (56) "Floor Space Index "or" FSI" means the quotient obtained by dividing the total covered area on all floors by the area of the plot i.e. FSI = Total covered area of all floors Plot Area (57) "Flue" means a confined space provided for the conveyance to the outer air of any product of combustion resulting from the operation of any heat producing appliance or equipment employing solid, liquid or gaseous fuel; (58) "Footing" means off set portions at the base of a foundation to provide a greater bearing area; (59) "Foundation" means that part of the structure which is below the lower most floor and which provides support for the super structure and which transmits loads of the super structure to the ground; (60) "Frontage" means the measurement of the side of any site abutting the road; (61) "Front Open Space / Margin / Setback" means the distance between the boundary line of plot abutting the means of access/road/street and the building line. In case of plots facing two or more means of access, roads / streets, the plot shall be deemed to front on all such means of accesses/roads/streets. (62) "Gallery" means an intermediate floor or platform projecting from a wall of an auditorium or hall providing extra floor, additional seating accommodation etc.; (63) "Garage Private" means a building designed or used for the parking of a motor car or other vehicles; (64) "Ground Coverage" means the quotient obtained in terms of percentage by dividing the plinth area of Ground Floor by plot area i.e. Ground Coverage = Plinth area of ground floor x 100 Plot Area (65) "Ground Level" means the finishing surface after formation cutting of the site from where erection of the building starts; (66) "Group Housing" means housing of more than one dwelling unit, where land is owned jointly as in the case of cooperative societies or public agencies such as Local Authorities or Housing Boards or[ II— 4] 59 property developers etc. and the construction is undertaken by one agency, but shall not include properties which are co-owned by family members; (67) "Habitable Room" means a room occupied or designed for occupancy by one or more persons for study, living, sleeping, eating, kitchen if it is part of living room but does not include bathroom, water closet compartments, laundries, serving and storage pantries, corridors, cellars, attics and other spaces that are not used frequently or for extended period; (68) "Height of a Room" means the vertical distance measured from the finished floor surface to the finished ceiling/slab surface; (69) "Internal wall" means all partition walls in the interior of a building excluding walls which abut exterior or interior open spaces; internal walls when made of bricks shall be a minimum of 100 mm brick work in suitable mortar; other non-load bearing partitions shall be of suitable thickness; (70) "Loft" means an intermediate floor in between two main floors but not more than 1.50 metre in height which may be adopted or constructed for storage purpose; (71) "Marginal Distance / Side and Rear Marginal Open Space" means a minimum distance required to be left open to sky between the boundary of the building plot and the building line on respective sides; (72) "Masonry" means the form of construction composed of brick, stone, tile, concrete blocks, gypsum or other similar building material units or combination of these material units laid up, bonded together and set in mortar; (73) "Materials Alteration" means a change of use in building materials in any existing building; (74) "Mezzanine Floor" means an intermediate floor between two floor levels above ground floor and at least one side of it should form an integral part of space/floor below; (75) "Mumty" means a structure with a covering roof over a staircase and its landing built to enclose only the stairs for the purpose of providing protection from weather and not meant for human habitation; (76) "Non-Combustible" means a material which does not burn or add heat to a fire when tested for combustibility in accordance with good practice; (77) "Occupancy" means the function or use of the building; (78) "Parapet" means a low wall built along the edge of a roof or a floor not more than 1.00 metre height; (79) "Parking Space" means an area enclosed or unenclosed sufficient in size to park vehicle together with a drive-way connecting the parking space with a street or alley and provided for ingress and egress of the vehicles; (80) "Partition" means an interior non-load bearing wall, one storey or part storey in height; (81) "Pavilion" means a flexible architectural open space that invites people to come in and spend time in it. It could be temporary or permanent and might even change its form and function. A pavilion might be used as a shelter, seating, meeting point, cafe, theatre, or for lectures, events, exhibitions, sports, play, relaxation and work etc; (82) "Pillar" means a wood, stone, brick, RCC or a metal pillar and includes all columns or upright post or support, stanchions (steel structures) and an assemblage of columns of stanchions properly riveted or welded or bolted together; (83) "Plinth" means the portion of a structure between the surface of the surrounding ground and surface of the floor, immediately above the ground; (84) "Porch or Portico" means covered surface supported on pillars or otherwise for the purpose of pedestrian or vehicular approach to a building; (85) "Public Building" means a building used or intended to be used either ordinarily or occasionally as a church, temple, mosque or any other place of public worship, dharamshala, college/school, hostel, theatre, cinema, public concert room, lecture room, library, orphanage, or rescue home or any other place of public assembly;60 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] (86) "Public Garage" means a building or portion thereof designed other than a private garage, operated for gains, designed or used for repairing, servicing, hiring, selling or storing motor driven or other vehicles; (87) "Repairs" means and includes the following activities, which do not otherwise violate any provisions regarding general building requirements, structural stability and fire safety requirements of these Bye- Laws: (a) Erection, Re-erection, Addition to, or Alteration of (i) an internal partition wall which does not involve sub-division of property, or (ii) a parapet wall or a cornice or chhajja within the boundaries of the permissible setbacks & ground coverage area of the site Provided that the total height of the parapet wall shall not be more than 1.00 metre and width of the cornice or chhajja shall not be more than 1.50 metre; (b) Repairing of a staircase; (c) White washing or painting; (d) Re-flooring of the surface of an existing floor; (e) Minor repairs and recasting of an existing damaged roof without changing the character and dimensions of such roof; (f) Erection of a false ceiling in any floor for air-conditioning, lighting or decorative purposes; (g) Plastering and Patch work; (h) Providing or closing an internal door or window or a ventilator not opening directly opposite a door or a window of another building; (i) Replacing of fallen bricks or stones; (j) Repairing or renewing existing plumbing, sanitary and other utility services; (k) Repairing of boundary wall; (l) Installation of air conditioner / water tank / solar plants / solar water heater etc; (88) "Residential Building" means a building used or constructed or adapted to be used wholly for human habitation; (89) "Residential cum Commercial Building" means a building where part of the building is used or constructed or intended to be used for human habitation with remaining part used or constructed or intended to be used for commercial purpose; (90) "Sanctioned Plan" means the set of plans and specifications submitted under section 235 of the Cantonments Act, 2006 under the Bye - Laws and regulations in connection with a building and duly sanctioned by the Authority under sections 234/237/238 of the Cantonments Act, 2006; (91) "Set Back Line" means a line usually parallel with the center line of the road or street and laid down in each case by the Board beyond which nothing can be constructed towards the road or street; (92) "Site or Plot" means a parcel/piece of land enclosed by definite boundaries; (93) "Smoke Pipe" means a flue approximately horizontal, made of metal or other material in which smoke or the products of combustion are conducted from a furnace to a chimney; (94) "Store or Shop" shall mean any store or shop in which it is not intended that any person shall reside;[ II— 4] 61 (95) "Storey" means the portion of a building included between the surface of any floor and the surface of the floor next above it, or if there be no floor above it, then the space between any floor and the ceiling next above it; (96) "Street" includes any way, road, lane, square, court, alley or passage in a Cantonment, whether a thoroughfare or not and whether built upon or not, over which the public have a right of way and also the road way or foot-way over any bridge or cause way; (97) "Structural Engineer" means a person who is a graduate of civil engineering from a recognized Indian or Foreign university duly approved by Government of India or is a member of Civil Engineering Division of the Institution of Engineers (India) with experience in structural engineering practice which includes structural design and field work; (98) "Sun shade" means a sloping or horizontal structural overhang usually provided over openings on an external wall to provide protection from Sun and rain; (99) "Swimming Pool" means a wading pool, paddling pool or simply a pool in container filled with water intended for swimming or water based recreation. The pool can be built either above or in the ground and from materials such as concrete, metal plastic or fiber glass; (100) "To Abut" means to be positioned juxtaposed to a road, lane, open space, building etc.; (101) "To Erect or Re-erect" means (a) To erect a new building on any site whether previously built upon or not; (b) To re-erect any building of which portion have been pulled down, burnt or destroyed, damaged by storm, rains, fire, earthquake or any other natural calamity to the same extent and similar specifications as existing prior to damage; (c) Conversion from one occupancy to another; (d) To carry out alterations and; (e) To add to a storey / storeys; (102) "Total Floor Area" means the area of all floors of building including habitable, basement and mezzanine floor; (103) "Travel distance" means the distance an occupant has to travel to reach the exit; (104) "Verandah" means a covered area with at least one side open to the outside; (105) "Warehouse" means a building, the whole or a substantial part of which is used or intended to be used for the storage of goods whether for keeping or for sale or for any similar purpose, but does not include a storeroom attached to and used for the proper functioning of a shop; (106) "Washing Platform" means an authorized platform for washing and also for servicing of scooters / cars etc.; (107) "Water Closet" means a privy with arrangements for flushing the pan with water but does not include bathroom; (108) "Water Course" means a natural channel meant for carrying storm water and includes an artificial one formed by training or diversion of a natural channel, (i) "Major Water Course" means a river. (ii) "Minor Water Course" means a nallah. (109) "Window" means an opening to the outside other than a door which provides all or part of the required natural light, ventilation or both to an interior space and not used as a means of ingress / egress; (110) "Workshop" means a room or a group of rooms or building in which goods are manufactured or repaired;62 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] (111) Words and expressions used and not defined in these Bye-Laws but defined in the Act shall have the same meanings as assigned to them in the Act. CHAPTER II PROCEDURE FOR SANCTION OF BUILDING PLANS AND RELATED DOCUMENTATION 3. BUILDING SANCTION REQUIRED: No person shall carry out any erection, re-erection, addition or alteration to any building or cause the same to be done without obtaining a sanction for such work from the Competent Authority. 4. PROCEDURE FOR OBTAINING BUILDING SANCTION:(1) An applicant who intends to erect or re-erect a building or to make addition or alteration in any building shall register himself/herself on the e- Chhawani portal and apply through online mode, duly enclosing all the requisite documents and plans, in e-Chhawani portal through Cantonment Board registered architect/engineer. (2) Only persons who have legally valid occupancy rights on leased or old grant or private land are eligible for applying for sanction of building plan. In cases wherein breach of lease conditions on leased land or breach of old grant terms in old grant land are involved, the Board shall have the right to refuse or reject applications for erections, re-erection or addition / alteration till the breach of lease or old grant conditions is regularized or condoned. (3) On scrutiny of the documents and plans submitted, the applicant receives the development charges communication (or the charges levied by the Board by whatsoever name these are known) for payment to Cantonment Board. (4) On deposition of development charges (or the charges levied by the Board by whatsoever name these are known) the sanction (if granted by the Board) is conveyed within the prescribed timelines. 5. BUILDING APPLICATION FEES AND APPLICABLE CHARGES: (1) Building Application Fees: The Building plan application shall be deemed valid only if the applicant has paid the requisite building application fee as determined by the Board. (2) Development Charges: The development charges, labour cess and other fees, as determined by the Board, are to be paid by the applicant through online mode before issuance of the sanction of the building application by the competent authority. (3) Incentive in development charges if Rooftop Solar Installation and Rain Water Harvesting is proposed and implemented: For construction of residential or commercial or any building less than 200.00 Sqmts if the applicant opts for Rooftop Solar Installation and/or Rain Water Harvesting, he/she shall be eligible for refund of development charges after the completion of said Rooftop solar installation and/or Rain Water Harvesting facility and submission of photographs to this effect. The quantum of incentive for different categories of buildings shall be decided by the Board through resolution. (4) Stacking of building material on street or other public land shall not take place without the permission of the Chief Executive Officer on a case-to-case basis and on payment of charges as fixed by the Chief Executive Officer in terms of Section 257 of the Act. 6. DOCUMENTS AT THE TIME OF APPLICATION: The following documents shall be submitted through online mode on e-Chhawani portal at the time of submitting application for building sanction: (i) Proof of ownership/HOR/Lessee/Successor/legal rights document; (ii) Affidavit and Indemnity Bond as specified by the competent authority; (iii) Proof of identity;[ II— 4] 63 (iv) Any other document as approved by the competent authority (Cantonment specific documents). 7. SANCTION / REFUSAL OF PLANS, VALIDITY PERIOD AND REVALIDATION PROCEDURE: (1) In case of old grant land, the proposed building plan shall be in conformity with the old grant terms and the land policies of Ministry of Defence. (2) In case of leased land, the proposed building plan shall be in conformity with the lease hold rights / terms and the land policies of Ministry of Defence. (3) The Competent Authority shall sanction the plan unless such building would contravene any of the following namely:- (i) That the building or the use of the site for the building or any of the particulars comprised in the site plan, ground plan, elevation, section or specification contravenes the provisions of the Act or the Bye-Laws made thereunder; (ii) That the notice for sanction does not contain the particulars or is not prepared in the manner required under the provisions of these Bye-Laws; (iii) That any information or documents required by the Board under these Bye-Laws has or have not been duly furnished; (iv) That the building plan is not in accordance with the Bye-Laws framed by the Board under section 260 or those framed under clauses (19) and (20) of section 348 of the Act; (v) That the building would be an encroachment on defence land or land vested in the Cantonment Board; (vi) That the site of the building does not abut on a street or projected street and that there is no access to such building from any such street by a passage or path-way appertaining to such site; or (vii) That the erection or re-erection of the building is not in conformity with any general scheme sanctioned under Section 240 of the Act; (viii) When the land on which it is proposed to erect or re-erect the building is entrusted to the management of the Board by the Government if the erection or re-erection constitutes a breach of terms of the entrustment of management or contravenes any of the instructions issued by the Government regarding the management of the land by the Board; (ix) When the land on which it is proposed to erect or re-erect the building is not held on a lease from the Government, if the right to build on such land is in dispute between the persons applying for sanction and the Govt; (x) That the minimum size of the plot for residential/commercial purpose is not less than 50.00 Sqmts / 15.00 Sqmts respectively; or (xi) That it is mandatory to provide Rooftop Solar Installation and Rain Water Harvesting if the size of the plot exceeds 200.00 Square metres; (4) The sanction once granted shall be valid for a period as provided in the Act from the date of issue of sanction. (5) The Building Sanction can be revalidated beyond the date of the expiry of the original Sanction of building plans on payment of the required revalidation fees as decided by the Board under provisions of the Act. Application for such revalidation shall be submitted on plain paper along with the following documents:64 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] (a) Original sanctioned plan. (b) Revalidation fees chargeable based on the decision and guidelines issued by Competent Authority from time to time. (c) Documents in support of construction, if any, having been done within valid period of sanction. (d) Certificate of supervision from Architect/Engineer/Supervising Engineer and the Applicant that the construction will be carried out under his supervision according to the plans sanctioned by the Competent Authority. [Minimum size of the plot for residential / commercial purpose shall not be less than 50.00 Sqmts / 15.00 Sqmts respectively, provided that for existing authorized buildings having a plot size of less than 50.00 Sqmts / 15.00 Sqmts, the said restriction shall not apply] 8. SCRUTINY OF BUILDING PLAN APPLICATIONS: Once the plans have been scrutinized and objections, if any, have been communicated through online mode, the applicant may modify the plan, comply with the objections raised and resubmit through online mode, for consideration of the competent authority. 9. REVOCATION OF SANCTIONED BUILDING PLANS AND LIABILITY OF THE APPLICANT TO CONFORM TO BYE-LAWS: (1) The Competent Authority may revoke any building sanction issued under the provisions of these Bye-Laws, whenever there has been any false statement, or any misrepresentation of material fact, or concealment of facts in the application or if any such sanction comes in contravention to new rule / law / notified issued by Central Govt. / State Govt. / any competent authority for such purpose on which the building sanction was based, and the whole work executed on the basis of such sanction shall be treated as unauthorized. Further, any or all executed works in cases of deviation from the sanctioned plan shall be treated as unauthorized construction and would lead to revocation of accorded sanction. (2) In the case of revocation of sanction during course of construction under above Bye- law, no compensation /damages shall be payable by the Competent Authority. (3) No such order of revocation shall be passed by the Competent Authority without giving a reasonable opportunity to the applicant of being heard. 10. NOTICE OF COMMENCEMENT AND COMPLETION OF WORK: (1) On issue of building sanction, the applicant shall commence the work for which the building sanction has been issued. The Applicant shall give notice to the Chief Executive Officer of his intention to start work on the building site by submitting Form D, set forth in the Appendix. Engineer will report that the site sanctioned has no construction / alteration from what has been submitted by applicant at the time of application for sanction of said building. (2) On completion of work, the Applicant shall submit a Notice of Completion of the building as per Form E, set forth in the Appendix through the Architect/Engineer who has supervised the construction within a period of thirty days from the date of completion of work.[ II— 4] 65 11. COMPLETION-CUM-OCCUPANCY CERTIFICATE: The Chief Executive Officer on receipt of the notice of completion shall inspect the work and issue a certificate of occupancy within the period stipulated in the Act, as per Form F, set forth in the Appendix, if the building has been constructed in conformity with sanction issued. 12. COMPOSITION OF UNAUTHORIZED CONSTRUCTION: (1) The Cantonment Board may by resolution decide formula to calculate quantum of penalty/fees for regularizatio no funauthorized construction. (2) Such composition of unauthorised construction shall be subject to the provisions of the Cantonments Act, 2006, the rules subsisting there under and other restrictions mentioned in these Bye-Laws including but not limited to FSI, Set-backs, and Ground Coverage. (3) In so far as constructions which are present and existing on the date of notifying of these Bye-Laws wherein such constructions are without sanction or in violation of approved plan including deviation, the applicants may apply to Cantonment Board for Compounding, which at the discretion of the Cantonment board or GoC-in-Chief, as applicable, may be allowed subject to payment of compounding fees as determined by Cantonment Board or GoC-in-Chief, as applicable. This exercise shall be undertaken subject to the Bye-Laws framed hereunder after approval of Central Government. CHAPTER III ZONING 13. ZONING: (1). The Cantonment should be divided into two broad zones namely:- (a) Zone I:- This would include civil areas and all privately held land comprising civilian habitation. This will be generally high population density areas. (b) Zone II:- All other land not included in Zone -I but inclusive of all Old Grant Bungalows and leases situated outside civil area. This will be generally low population density zone. (2) Zone-I: The Zone comprises all lands as depicted in Zonal Plan passed by the Board by resolution in this regard. (a) Requirement of Site: No piece of land shall be used as a site for the construction of a building if the Competent Authority considers that the site is insanitary or is not drained properly or is incapable of being well drained. (b) Permissible FSI: The permissible FSI, depending on the plot size, shall be as per table below: Table: FSI in Zone I (Residential Plots / Multiple Units) S.No. Area of plot in Square metres FSI 1 50-150 1.80 2 151-250 1.70 3 251–350 1.60 4 351-450 1.50 5 451-550 1.40 6 551-750 1.30 7 751-1000 1.20 8 Greater than 1000 1.1066 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] Table: FSI in Zone I (Commercial Plots) S.No. Area of plot in Square metres FSI 1 15-100 1.50 2 101-200 1.50 3 201-500 1.50 4 501-2000 2.00 5 2001-2500 2.00 6 Greater than 2500 2.20 (c) Tenement Density: No independent dwelling unit of less than 10 Sq.mt can be constructed if the plot size is more than 50 Sq.mt. (d) Building Height: Minimum height of floors in buildings falling in this zone shall be 2.70 metres measured from the surface of the floor to the lowest point of the ceiling i.e. bottom of slab and the total height of all buildings in all plot categories shall not be more than 11.50 metres from ground level including height of the stilt floor. It is stated that not more than one basement should be considered and should be used only for parking, storage and housing services. Basements in no case be used for residential or commercial purposes. (e) Maximum Number of Storeys Permissible: The maximum number of storeys permissible in all categories of plots in Zone-I shall be G+2/Stilt+3, if stilt is used for parking. [The building plans earlier sanctioned by the Board for more than G+2/Stilt+3 will remain valid but no new plan for more than G+2/Stilt+3 will be sanctioned] (3) Zone-II: The Zone comprises all lands as depicted in Zonal Plan passed by the Board by resolution in this regard. (a) Requirement of Site: No piece of land shall be used as a site for the construction of a building if the Competent Authority considers that the site is insanitary or is not drained properly or is incapable of being well drained. (b) Permissible FSI: The permissible FSI, depending on the plot size, shall be as per table below: Table: FSI in Zone II (Residential Plots/Multiple Units) S.No. Area of Plot in Square metres FSI 1 50-150 1.80 2 151-250 1.70 3 251–350 1.60 4 351-450 1.50 5 451-550 1.40 6 551-750 1.30 7 751-1000 1.20 8 Greater than 1000 1.10 Table : FSI in Zone II(Commercial Plots) S.No. Area of plot in Square metres FSI 1 15-100 1.50 2 101-200 1.50[ II— 4] 67 3 201-500 1.50 4 501-2000 2.00 5 2001-2500 2.00 6 Greater than 2500 2.20 Table: FSI in Zone II (Educational/Medical Institutes) S.No. Uses of Land Minimum Area Required FSI (Square metres) 1 Nursery School / Primary 400.00/2000.00 1.00 2 Secondary School/High 4000.00/15000.00/15000.00 1.60 School/Intermediate 3 Higher Education Institute 20000.00 2.11 4 Laboratory/Clinics 300.00 1.80 5 Maternity Homes & Child 750.00 1.50 care centre/Nursing Home/Dispensary 6 Hospital Upto 50 beds 2000.00 1.50 7 Hospital 51-200 beds 5000.00 2.00 (c) Tenement Density: No independent dwelling unit of less than 10 Sq.mt can be constructed if the plot size is more than 50 Sq.mt. (d) Building Height: Minimum height of floors in buildings falling in zone-II shall be 2.70 metres measured from the surface of the floor to the lowest point of the ceiling i.e. bottom of slab and the total height of all buildings in all plot categories shall not be more than 11.50 metres from ground level including height of the stilt floor. It is stated that not more than one basement should be considered and should be used only for parking, storage and housing services. Basements in no case be used for residential or commercial purposes (e) Maximum Number of Storeys Permissible: The maximum number of storeys permissible in all categories plots in Zone-II shall be G+2 / Stilt+3, if stilt is used for parking. CHAPTER IV SPECIFICITIES WITH RESPECT TO BUILDING CONSTRUCTION 14. OPEN SPACES / SETBACKS: The building envelope shall be governed by the following minimum clear open space and setbacks: - (1) Front Setback (a) Every building abutting a street/footpath shall have a front setback from the front property line to the front building envelope or building front main wall. (b) External staircases in the front elevation of the building shall not be considered in front set back calculation. (c) Sunshades and balconies shall be within the front property line or shall be constructed within the front setback or within the boundary wall of the plot. (d) In the case of school buildings, the front boundary wall shall be recessed by 5.00 metres to accommodate visitor parking within setback area. (2) Side and Rear Setback (a) Every building shall have a minimum clear side and rear setback as prescribed in these Bye-68 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] Laws. No use is permitted in this open space except steps, staircases, rain water harvesting pits, septic tank and soak pit or in case this space is 5.00 metres wherein parking of vehicles is allowed. (b) External staircases in the sides and rear of the building shall not be considered in setback calculation and shall be as per the following table and shall be constructed within the boundary wall of the plot. (c) Sunshades and balconies shall be within the boundary wall of the plot. The provisions for open spaces at the front, side and rear of the building shall be as per Table below: Table: Minimum Building Setback (Residential Plots / Multiple Units) S.No Plot size (in Square metres) Minimum set back (in metres) Front Rear Side(1) Side(2) 1 50–75 1.20 -- -- -- 2 76-150 2.00 1.50 -- -- 3 151-300 3.00 2.00 -- -- 4 301-500 4.50 3.00 1.50 -- 5 501-750 5.50 3.50 3.00 2.00 6 751-1000 6.50 4.00 3.50 3.00 7 Greater than 1000 7.50 4.00 4.00 4.00 Table: Minimum Building Setback (Commercial Plots) S.No Plot size (in Square metres) Minimum set back(in metres) Front Rear Side(1) Side(2) 1 Upto 200 4.50 -- -- -- 2 201-400 6.00 2.00 3.00 -- 3 401-600 7.50 3.00 3.00 -- 4 601-1000 8.00 3.00 4.00 1.50 5 1001-1500 9.00 4.00 4.50 3.00 6 1501-3000 10.00 5.00 4.50 4.50 7 Greater than 3000 12.00 6.00 6.00 6.00 Table: Minimum Building Setback (Educational / Medical Institutes) S.No Plot size (in Square metres) Minimum set back(in metres) Front Rear Side(1) Side(2) 1 Upto 1000 6.00 4.50 3.60 3.60 2 1001-3000 7.50 4.50 4.50 4.50 3 3001-8000 9.00 6.00 4.50 4.50 4 8001-15000 12.00 6.00 6.00 6.00 5 15001-35000 15.00 6.00 6.00 6.00 6 Greater than 35000 18.00 6.00 6.00 6.00[ II— 4] 69 Also, following points should be considered while deciding on the setback: (i) For small plots of size 75 Sqmts or less, the Boards may do away with requirement of setbacks except front setback of minimum 1.20 metre. (ii) For plots size between 76.00 Sqmts to 1000 Sqmts, minimum 2.00 metres front and 1.50 metre rear setback should be given. (iii) The loss due to setback in existing buildings with sanctioned plan may be compensated by allowing additional space on higher floors. (3) Interior Open Space-Ventilation Shaft: For ventilating the spaces for bathroom and water closet, if not opening on to front, side, rear or interior (courtyard) open spaces, these shall open on the ventilation shaft, the size of which shall not be below values indicated in table below: Table: Minimum Size of Ventilation Shaft S.No. Building Height in Size of Shaft in Minimum one dimension in metres Square metres metres. 1 Upto 6.00 1.20 0.90 2 More than 6.00 2.80 1.30 15. LANDS SITUATED IN ARCHAEOLOGICAL ZONE: For plots falling in Archaeological Zone, NOC from Department of Archaeological Survey of India shall be submitted. 16. RESTRICTIONS TO HEIGHT IN THE VICINITY OF AERODROMES: For building in the vicinity of aerodromes, the maximum height of such building shall be decided in consultation with the Civil Aviation Authorities and in such cases, applicant shall obtain 'no-objection' from the Civil Aviation Authorities. 17. PARKING SPACE: (1) Parking provision for different types of buildings shall be as per norms laid out by the National Building Code of India (Code 10.3 Part 3) as amended from time to time and it includes parking of all vehicles like cars, scooters, cycles and light and heavy commercial vehicles. (2) These parking norms shall be applicable for all new applications for building plan sanctions. 18. PLINTH OF MAIN BUILDING: The plinth of any part of a building shall be so located with respect to surrounding ground level that adequate drainage of the site is assured but not at a height of less than 0.30 metre. 19. PLINTH OF INTERIOR COURTYARDS: Every interior courtyard shall be raised at least 0.30 metre above the surrounding ground level and shall be satisfactorily drained. 20. SIZE OF HABITABLE ROOMS: (1) No habitable room shall have an area of less than 9.50 Square metres. (2) The minimum width of a habitable room shall be 2.40 metres. (3) In a two-room tenement, one shall be not less than 9.50 Square metres and other 7.50 Square metres with a minimum width of 2.10 metres. (21) HEIGHT OF HABITABLE ROOM: (1) The height of all rooms for human habitation shall not be less than 2.70 metres measured from the surface of the floor to the lowest point of the ceiling i.e. bottom of the slab. (2) In case of centrally air-conditioned building, height of the habitable room shall not be less than 3.00 metres measured from the surface of the floor to the lowest point of air conditioning duct or false ceiling. (3) In the case of pitched roof, the average height of rooms shall not be less than 3.90 metres. The minimum clear headroom under a beam, folded plates or eaves shall be 2.40 metres. (22) BATHROOMS AND WATER-CLOSETS (COMBINED): (1) Size: The minimum size of a bathroom shall be 1.80 Square metre and the minimum width of a side shall be 1.20 metre. The minimum size of a water closet shall be 1.10 Square metre and the minimum width of a side shall be 0.90 metre. The minimum size of a combined bathroom and water closet shall be 2.80 Square metres70 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] and the minimum width of a side shall be 1.20 metre. (2) Height: The height of a bathroom or water closet measured from the surface of the floor to the lowest point in the ceiling i.e. bottom of slab shall not be less than 2.10 metres. (3) Other Requirements: A bathroom or water closet shall: (a) Be so situated that at least one of its walls shall open to external air and shall have a minimum opening in the form of a ventilator or window of 0.30 Square metre. (b) Not be directly under or above any room other than another water closet, bathroom, washing area or terrace unless it has a water tight floor. (c) Have the platform and / or seat made of water tight non-absorbent material. (d) Be enclosed by walls/partitions whose surface is finished with a smooth impervious material to a minimum height of 0.45 metre above the floor level. (e) Be provided with an impervious floor finish, with floor surface sloping towards the drain with a suitable grade and not towards any other habitable room. (4) No room containing water closets shall be used for any purpose except as a lavatory and no such room shall open directly into a kitchen or cooking space by a door, window or other opening. Every room containing water closets shall have a door completely closing the entrance to it. (23) KITCHEN: (1) Size: The minimum area of the kitchen shall be 5.0 Square metres and the minimum width of a side shall be 1.80 metre. The minimum area of the kitchen which is also intended to be used as dining room shall be 7.50 Square metres and the minimum width of a side shall be 2.10 metres. (2) Height: The height of a kitchen measured from the surface of the floor to the lowest point in the ceiling i.e. bottom of slab shall not be less than 2.75 metres. (3) Other Requirements: Any room to be used as kitchen shall have: (a) a height of not less than 2.75 metres; (b) a window the size of which shall be subject to Bye-law No. 31.4 opening directly to an interior or exterior open space, but not into a shaft; (c) unless separately provided for in a pantry, means for the washing up of kitchen utensils which shall lead directly or through a sink to a grated and trapped connection to the waste pipe; (d) be enclosed by walls/partitions whose surface is finished with a smooth impervious material to a minimum height of 2.75 metres above the floor level; (e) be provided with an impervious floor finish; with floor surface sloping towards the drain with a suitable grade and not towards any other habitable room. Note:- It is mandatory to make strict provisions for laying out gas pipeline from kitchen to ground floor. The provision for storage of cylinders should be kept on ground floor so that in future it can be connected with the central gas supply. [Specification follows as mentioned in the guidelines of GAIL (Gas Authority of India Limited]. (24) PANTRIES: Pantries shall have:- (1) a floor area of not less than 3.00 Square metres and a minimum width of a side shall be 1.50 metre; (2) a sink for cleansing of kitchen's utensils which shall drain through a grated and trapped connection to the waste pipe; (3) been enclosed by walls/partitions whose surface is finished with a smooth impervious material to a minimum height of 2.75 metres above the floor level; (4) been provided with an impervious floor finish, with floor surface sloping towards the drain with a suitable grade and not towards any other habitable room. (25) LOFT: (1) The maximum height of a loft shall be 1.50 metre and the loft may be provided over corridors and passageways only.[ II— 4] 71 (2) The clear head room under the loft shall not be less than 2.20 metres, (3) Loft when provided in a commercial building, shall be located 2.00 metres away from the entrance; (26) MEZZANINE FLOOR: (1) Size: Mezzanines shall not be sanctioned in residential buildings. When provided in commercial buildings, the aggregate area of the mezzanine floor shall not exceed 33 percent of the built-up area of that floor. (2) Height: The minimum height of a mezzanine floor shall be 2.20 metres. The head room under mezzanine floor shall not be less than 2.20 metres. (3) Other Requirements: A mezzanine floor may be sanctioned over a room or a Compartment provided that: (a) In mezzanine floor, rooms and any structure constructed with closed roof and side walls for any purpose shall be included in FSI but in case the mezzanine floor is constructed for interior architectural decorative purpose and other passage purposes with adequate handrails shall not be counted in FSI. (b) In case the size of mezzanine floor is 9.50 Square metres or more, it should conform to the standard of living room in so far as lighting and ventilation is concerned. (c) It is so constructed as not to interfere under any circumstances with the ventilation of the space over and under it; (d) Such mezzanine floor or any part of it shall not be used as a Kitchen. (e) In no case shall a mezzanine floor be closed so as to make it liable to be converted into unventilated compartments. (27) GARAGE: (1) Individual private garage: The size of a private garage in residential building shall be not less than 2.75 metres x 5.00 metres. The garage if located in the side, open space shall not be constructed within 2.00 metres from the main building. (2) Commercial/Public Garage: The size of a public garage shall be calculated based on the number of vehicles to be parked and the minimum parking space is as specified in Bye-Law No.17. (3) Height: The maximum head room in a garage and parking area shall be 2.40 metres. (4) The plinth of a garage located at ground level shall not be less than 0.30 metre above the surrounding ground level. (5) The garage shall be set back behind the building line for the street/road on to which plot abuts and shall not be so located to affect the access ways to the building. (6) Corner site: When the site fronts on two streets, the frontage would be as on the street having the larger width. In cases where the two streets are of the same width, then the larger depth of the site will decide the frontage and open spaces. In such cases the location of a garage if provided within the open spaces shall be located diagonally opposite the point of intersections. (28) ROOF: (1) The roof of a building shall be so constructed or formed as to ensure effectual drainage of the rainwater there from by means of sufficient rain water pipes of adequate size, whenever required so arranged, joined and fixed as to ensure that the rain water is carried away from the building without causing damage in any part of the walls or foundation of the said building or those of an adjacent building. (2) Rainwater from roofs and open areas on the plot shall be collected by suitable means to recharge pits and other devices. In this context reference may be made to Part 9 Plumbing Services Section 1: Water Supply, Drainage and Sanitation of the National Building Code of India as amended from time to time. (3) Rainwater pipes shall be affixed to the outside of the walls of the building or in recesses or chases out or formed in such walls or in such other manner as may be approved by the Competent Authority. (4) Terrace of buildings shall not be subdivided and it shall have a common access. (29) BASEMENTS:(1) Basements may be erected within the prescribed setbacks and prescribed building lines and subject to maximum coverage on ground floor.72 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] (2) Basements shall not be used for residential purposes and to be constructed within the building envelope and subject to maximum coverage on floor 1 (entrance floor) and used only for: (a) storage of household or other goods except inflammable materials; (b) strong room, bank cellars etc.; (c) air-conditioning equipment and other machines used for services and utilities of the building; (d) parking spaces. (3) Basements shall have the following requirements namely:- (a) Every basement shall be in every part at least 2.70 metres in height from the floor to the underside of the slab or ceiling. (b) Adequate ventilation shall be provided for the basement. The standards of ventilation shall be the same as required by the particular occupancy according to Bye-Laws. Any deficiency may be met by providing adequate mechanical ventilation in the form of blowers or exhaust fans at the rate of one exhaust fan for 50 Sq.mt floor area. (c) The minimum height of the ceiling of any basement shall be 0.90 metre and the maximum 1.20 metre above the average surrounding ground level. (d) Adequate arrangement shall be made so that surface drainage or drainage water does not enter the basement. (e) The basement shall not be partitioned. In cases where partitions are allowed by Competent Authority and the ventilation standards as laid-down in (b) above are met, the partitioning of basement may be sanctioned, subject to the condition that no space shall be less than 10.00 Square metres. (f) Adequate protection against the fire shall be provided. The roofs separating basement and floors above shall be constructed of a material like R.C.C. or of such material which will provide resistance against fire for at least two hours. (g) Where a basement is sanctioned in apartment houses (residential flats) and hotels, the Applicant/ Occupier shall display the basement plan at the entrance. Thimbles shall be provided in the roof of the basement and their positions clearly indicated on the plan. One fire extinguisher for every 50.00 Square metres of basement area or part thereof shall be provided. (h) The walls and floors of the basement shall be water-tight and so designed that the effect of surrounding soil moisture, if any, are taken into consideration and adequate damp proofing treatment is given. (i) In the event of atmospheric water percolating into basement necessary arrangement to drain out the same shall be provided. (j) Kitchen, bath and water closet shall not be sanctioned in the basement unless the sewer levels allow the same and there is no chance of backflow and flooding of sewage. If sanctioned they shall be placed against the external walls of the basement (which shall also be the external walls of the building) and shall be adequately lighted and ventilated. The area of such kitchens and baths shall be counted in the FSI. Only 1.00 Square metre water-closet provided in the basement shall be excluded from the FSI calculations. (k) A kitchen when sanctioned in the basement shall be equipped with electric ovens, stoves, gas only. No coke or fire wood will be used. (l) The access to the basement shall be separate from the main and alternate staircase providing access and exit from higher floors. Where the staircase is continuous the same shall be enclosed type serving as a fire separation from the basement floor and higher floors. Open ramps shall be sanctioned if they are constructed within the building line subject to suitable drainage provision. (m) In case of basements of office and commercial occupancy, sufficient number of exit ways and access ways shall be provided as per norms stated in the National Building Code of India.[ II— 4] 73 (30) CHIMNEYS: (1) Chimneys, where provided shall conform to the requirements of I.S 1645-1960 Indian Standards Code of practice for fire safety of building (General) chimneys, Flues, Flue pipes and Hearths. (2) The chimneys shall be built at least 0.90 metre above the top of the roof provided the top chimney shall not be below the tops of adjacent parapet wall. In the case of sloping roof, the chimney top shall not be less than 0.60 metre above the ridge of the roof in which the chimney penetrates. (31) LIGHTING AND VENTILATION OF THE ROOMS: (1) The whole or part of one side of one or more rooms intended for human habitation and not abutting on either the front, rear or side open spaces shall abut on an interior open space whose minimum width in all directions shall be 1.00 metre in case of buildings not more than 6.00 metres in height and subject to the provision of increasing the same with increasing height of 0.1 metre per every metre height or part thereof beyond 6.00 metres. However, in case of buildings already constructed with 3.00 metres the open space for new construction on upper floor, the open space on this basis shall be ensured and would remain as mandatory open space. (2) Where the lighting and ventilation requirements are not met through daylight and natural ventilation, the same shall be ensured through artificial lighting and mechanical ventilation as per part VIII Building Services Section 1 Lighting and Ventilation of National Building Code of India as amended from time to time published by the Indian Standard Institution. The latest version of the National Building Code of India shall be considered at the time of enforcement of these Bye-Laws. (3) The minimum aggregate area of opening of habitable room excluding doors and fixed glazing but including the frame shall be not less than 15 % of floor area of the room. (4) The minimum aggregate area of opening of kitchens excluding doors and fixed glazing but including the frame shall be not less than 5% of floor area of the kitchen. (5) No portion of a room shall be assumed to be lighted if it is more than 4.00 metres from the opening assumed for lighting of that portion of the room. (6) In lodges and hotels where attached toilets whose walls are not abutting on an external wall are provided, mechanical ventilation system should be installed as per the provisions of the part VIII of National Building Code of India as amended from time to time published by the Indian Standard Institution. (32) PARAPETS: Parapet walls and hand rails provided on the edges of roof terrace, balcony, etc. shall not be less than 0.90 metre and not more than 1.00 metre in height. The specified height shall not apply when roof terrace is not accessible by a staircase. (33) BOUNDARY WALL: Except with the permission of the Chief Executive Officer, under Section 261 of the Cantonments Act, 2006 boundary wall, hedges, fences on any land in the Cantonment shall not be erected and the maximum height of the boundary wall shall not exceed 2.5 metres above the centerline of the street. (34) EXIT REQUIREMENTS: (1)General requirements: (a) Every building meant for human occupancy shall be provided with exits sufficient to provide for safe escape of occupants in case of fire or other emergency. (b) In every building, exit shall comply with the minimum requirement of this part, except those not accessible for general public use. (c) All exits shall be free of obstructions. (d) No building shall be altered so as to reduce the number, width or protection of exits to less than that required. (e) Exits shall be clearly visible and the routes to reach the exit shall be clearly marked and sign posted to guide the population of floor concerned. (f) All exit ways shall be properly illuminated. (g) Fire fighting equipment where provided along exits shall be suitably located and clearly marked but must not obstruct the exit way and yet there should be clear indication about its location from either side of the exit way.74 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] (h) Alarm devices shall be installed to ensure prompt evacuation of the population concerned though the exits, wherever required. (i) All exits shall provide continuous means of egress to the exterior of a building or to an exterior open space leading to a street. (j) Exits shall be so arranged that they may be reached without passing through another occupied unit, except in the case of residential buildings. (2) Types of Exits: (a) Exits shall be either of horizontal or vertical type. An exit may be doorway, corridor passageway, ramp, internal staircase or external staircase, to an internal or external open area, verandah and/or terrace which have access to the street or to roof of a building. (b) An exit may also include a horizontal exit leading to an adjoining building at the same level; and (c) Lifts, escalators and revolving doors shall not be considered as exits. (3) Number and Size of Exits: The requisite number and size of various exits shall be provided, based on the population in each room, area and floor based on the occupant load, capacity of exits, travel distance and height of buildings. (a) Arrangement of Exits: Exits shall be so located that the travel distance on the floor shall not exceed 22.50 metres for residential, educational, institutional and hazardous occupancies and 30.00 metres for assembly, business, mercantile, industrial and storage occupancies. Whenever more than one exit is required for a floor of a building, exits shall be placed as remote from each other as possible. All the exits shall be accessible from the entire floor area at all floor levels. The travel distance to an exit from the remote point shall not exceed half the distance as stated above except in the case of institutional occupancy wherein it shall not exceed 6.00 metres. (b) Occupant Load: The population in rooms and areas of floors shall be calculated based on the occupant load as provided in National Building Code and amended time to time. (c) Capacity of Exits: The capacity of exits (doors and stairways) indicating the number of persons of that could be safely evacuated through a unit exit width of 0.50 metre shall be as per the National Building Code amended from time to time. (4) Doorways: (a) Every exit doorway shall open into an enclosed stairway, a horizontal exit, on corridor or passageway providing continuous and protected means of egress. (b) No exit doorway shall be less than 1.00 metre in width. Doorways shall be not less than 2.10 metres in height. Doorways for bathrooms, water closet stores etc. shall not be less than 0.75 metre wide. (c) Exit doorways shall open outwards, that is, away from the room but shall not obstruct the travel along any exit. No door, when opened, shall reduce the required width of stairway or landing to less than 1.20 metre. Overhead or sliding doors shall not be installed. (d) Exit door shall not open immediately upon a flight of stairs. A landing equal to at least the width of the door shall be provided in the stair way at each doorway. Level of landing shall be the same as that of the floor which it serves. (e) Exit doorways shall be open-able from the side which they serve without the use of a key. (f) Revolving doors shall not be allowed. (5) Stairway: (a) For assembly, business, educational, hazardous, industrial, mercantile, multi- storey and public buildings there shall be a minimum of two staircases and one of them shall be an enclosed stairway and the other shall be on the external wall of the building and shall open directly to the exterior, interior open space or to any open space for safety. Single staircase may be accepted for educational, business or residential building where floor area does not exceed 500.00 Square metres and height of building does not exceed 12.00 metres and other requirements of occupant load, travel distance and width of staircase shall meet the requirement. The single staircase in such cases shall be on the outer wall of the building. (b) Internal stairs shall be constructed of non-combustible materials throughout;[ II— 4] 75 (c) Internal stairs shall be constructed as a self-contained unit with at least one side adjacent to an external wall and shall be completely enclosed; (d) The minimum width of an internal staircase shall be 1.00 metre. Columns and other building features shall not reduce the width of the staircase. (e) The minimum width of treads without nosing shall be 250 millimetres for an internal staircase for residential buildings. In the case of other buildings, the minimum tread shall be 300 millimetres. The treads shall be constructed and maintained in a manner to prevent slipping. (f) The maximum height of riser shall be 190 millimetres in the case of residential buildings and 150 millimetres in the case of other buildings. They shall be limited to 12 per flight. (g) Handrails shall be provided with a minimum height of 0.90 metre from the centre of the tread; (h) The minimum head room in a passage under the landing of a staircase and under the staircase shall be 2.10 metres. Beams and other building features shall not reduce the head room of the staircase. (i) No living space, store or other fire exits shall open directly into the stairwell of the staircase. (j) The external exit door of the staircase enclosure at ground level shall open directly to the open spaces or should be reached without passing through any door other than a door provided to from a draught lobby. (k) The main staircase and fire escape shall be continuous from ground floor to the terrace level. (l) No electrical shafts/AC ducts or gas pipe etc. shall pass through the staircase. (m) Lift shall not open in staircase landing. (n) No combustible material shall be used for any surface decoration in the staircase. (o) A staircase shall not be arranged around a lift shaft. (p) The exit signs with arrow indicating the way to escape route shall be provided at a suitable height from the floor level on the wall and shall be illuminated by electric light connected to corridor circuits. All exit way marking signs of suitable size should be flushed with the wall and so designed that no mechanical damage shall occur to them due to moving of furniture or other heavy equipment. Further all landings of floor shall have floor indication boards indicating the number of floors as per bye-law. The floor signage indicator shall be placed on the wall immediately facing the flight of stairs and nearest to the landing. It shall be of size not less than 0.50 metre X 0.50 metre. (q) In case of single staircase, it shall terminate at ground floor level and access to the basement shall be by a separate staircase. However, second staircase may lead to basement levels provided the same is separate at ground level by either a ventilated lobby with discharge points at two different ends or through enclosures. (6) Fire Escapes or External Stairs: (a) Fire escapes shall not be considered in calculating the evacuation time of a building. (b) All fire escapes shall be directly connected to the ground. (c) Entrance to fire escape shall be separate and remote from the internal staircase. (d) The route to fire escape shall be free of obstructions at all times, except a doorway leading to the fire escape which shall have the required fire resistance. (e) Fire escape shall be constructed of non-combustible materials. (f) Fire escapes stairs shall have straight flight not less than 1.20 metre wide with 280 millimetres treads and risers not more than 190 millimetres. The number of risers shall be limited to 16 per flight. (g) Handrails shall be of a height not less than 1.00 metre.76 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] (7) Ramps: (a) Ramps with a slope of not more than 1:10 to 1:12 may be substituted for and shall comply with all the applicable requirements of required stairways as to enclosure capacity and limiting dimensions Ramps shall be surfaced with approved non-slipping materials. (b) The minimum width of the ramps in hospitals shall be 2.50 metres; (c) Handrails shall be provided on both sides of the ramp; (d) Ramps shall lead directly to outside open space at ground level or courtyard or safe place. (8) Corridors: (a) The minimum width of a corridor shall not be less than 1.00 metre in the case of 3 storey row housing residential building. For all other buildings minimum width shall be 2.00 metres. (b) In case of more than one main staircase of the building interconnected by a corridor or other enclosed space there shall be at least one smoke stop door across the corridor or enclosed space between the doors in the enclosing walls of any two staircases. (35) NON-FSI SPACES: The following shall not be included in FSI calculation: (a) In the terrace above the top most storey, areas covered by stair-case rooms and lift rooms and passages thereto, architectural features, elevated tanks (provided its height below the tank from the floor does not exceed 2.0 metres) and WC (with floor area not exceeding 2.50 Sq.mt). (b) Staircase and lift rooms and passage thereto in the stilt parking floor or upper floors used for parking. (c) Staircase and lift rooms and passage thereto in the basement floor or floors used for parking. (d) Area of the basement floor or floors used for parking. (e) Area of the stilt parking floor provided it is open on sides, and used for parking. (f) Servants or drivers bath room and water closet for each block in cases of Non-High-Rise Buildings at ground floor or stilt parking floor. (g) Watchman booth. (h) Caretaker booth or room in ground floor or stilt parking floor. (i) One toilet in each floor not exceeding 2.50 Sq.mt. CHAPTER V INCLUSIVE DESIGN (36) FACILITIES IN THE PUBLIC BUILDING FOR THE DIFFERENTLY-ABLED PERSONS: These provisions are applicable to all buildings, recreation areas and facilities used by public. It does not apply to private domestic residences. (1) Site planning: Level of the roads, access paths and parking areas shall be described in the plan along with specification of materials. Every building should have at least one access to main entrance/exit to the differently-abled which shall be indicated by proper signage. This entrance shall be approached through a ramp together with stepped entry. The ramp should have a landing after every 1.0 metre run and in front of the doorway. Minimum size of landing shall be 1.20 metre. (2) Access path/Walk way: Access path from plot entry and surface parking to building entrance shall be a minimum of 1.50 metre wide having even surface without any step. Slope, if any shall not have gradient greater than 1:20. Selection of floor material shall be made suitably to attract or to guide visually impaired persons (limited to floor material) whose colour texture is conspicuously different from that of the surrounding floor material or the material that emit different sound to guide visually impaired persons. Finishes shall have a non-slip surface with texture traversable by a wheel chair. Curbs wherever provided should blend to common level. (3) Parking: For parking of vehicles of differently-abled people, the following provisions shall be made: (a) Surface parking for two Equivalent Car Spaces (ECS) shall be provided near entrance for the differently-abled persons with maximum travel distance of 30.0 metres from building entrance. (b) The width of parking bay shall be minimum 2.80 metres.[ II— 4] 77 (c) The information stating that the space is reserved for wheel chair users shall be conspicuously displayed. (d) Guiding floor materials shall be provided or a device which guides visually impaired persons with audible signals or other devices which serves the same purpose shall be provided. (4) Building Requirements: The specified facilities for the buildings for disabled persons shall be as follows: (a) Approach to plinth level. (b) Corridor connecting the entrance / exits for the differently-abled. (c) Stair-ways. (d) Lift. (e) Toilet. (f) Drinking water. (g) Braille signage shall be provided at the above specified facilities. (5) Approaches to Plinth Level: (a) Ramp shall be provided with non-slip material to enter the building minimum clear width of ramp shall be 1.50 metre with maximum gradient 1:20, between top and bottom of the ramp. Length of ramp shall not exceed 12 metres having 0.90 metre high handrail on both sides extending 300 millimetres beyond the ramp. Minimum gap from the adjacent wall to the handrail shall be 40 millimetres. (b) Minimum clear opening for the entrance door shall be 1.00 metre. Threshold shall not be raised more than 300 millimetres. (c) For stepped approach, size of tread shall not be less than 300 millimetres and maximum riser shall be 150 millimetres. Provision of 0.90 metre high handrails on both sides of the stepped approach similar to the ramped approach shall be made. (6) Corridor connecting the entrance/exit for the differently-abled: The corridor connecting the entrance/exit for differently-abled leading directly outdoors to a place where information concerning the overall use of the specified building can be provided to visually impaired person either by a person or by signs, shall be provided as follows: (a) Guiding floor materials shall be provided or devices that emit sound to guide visually impaired persons. (b) The minimum width shall be 1.50 metre. (c) Incase there is a difference of level, slope ways shall be provided with a slope of 1:20. (d) Handrails shall be provided for ramps / slope ways. (7) Stairways: Stairways with open riser and provision of nosing shall not be sanctioned. (8) Lifts: Wherever lift is necessary, provision of at least one lift shall be made for the wheel chair user with the following car dimensions of lift recommended for passenger lift for 13 persons capacity by Bureau of Indian Standards. (a) Clear internal depth minimum of 1.10 metre. (b) Clear internal width minimum of 2.0 metres. Entrance door width shall be 0.90 metre. (c) A handrail not less than 0.60 metre long at 1.0 metre above floor level shall be fixed adjacent to the control panel. (d) The lift lobby shall be of an inside measurement of 1.80 metre x 2.0 metres or more. (e) The Braille signage will be posted outside the lifts. (f) Operational details of lifts shall conform to the National Building Code of India and will be the responsibility of designer as well as manufacturer. (9) Toilets: One special water closet in a set of toilets shall be provided for the use of differently-abled with essential provision of washbasin near the entrance for the differently-abled.78 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] (a) The minimum size shall be 1.370 metre x 1.750 metre. (b) Minimum clear opening of the door shall be 0.80 metre and the door shall be swing or sliding type. (c) Suitable arrangement for vertical/horizontal handrails with 40 millimetres clearance from wall shall be made in the toilet. (d) The water closet seat shall be 0.50 metre from the floor. (10) Refuge: An alternative to immediate evacuation of a building via staircases and/or lifts is required for the movement of differently-abled persons to areas of safety within a building. If possible, they could remain there until the fire is controlled and extinguished or until rescued by fire fighters. (a) A refuge area may be provided at the fire protected stair landing on each floor that can safely hold one or two wheelchairs. (b) The area shall have doorways with clear opening width of 900 millimetres. (c) The area shall have an alarm switch installed between 900 millimetres and 1200 millimetres from the floor level. (d) Refuge area is mandatorily to be provided for the plot size of 10 Sqmts and above. CHAPTER VI PROVISIONS OF STRUCTURAL SAFETY, ELECTRICAL AND PLUMBING SERVICES, WATER SUPPLY, ETC. (37) LANDSCAPING: Institutional, Industrial, Commercial and Group Housing Complexes shall be required to plant a minimum number of trees as per Table below: Table: Number of trees to be planted. SI. Plot Area (Square No. of trees required metres) No. 1 up to100 One tree per 30.00 Square metres of open space out of which minimum 50% trees to be in the category of evergreen trees having height of 4.00 metres or more 2 More than 100 – 200 One tree per 20.00 Square metres of open space out of which minimum 50% trees to be in the category of evergreen trees having height of 4.00 metres or more 3 More than 200 One tree per 15.00 Square metres of open space out of which minimum 50% trees to be in the category of evergreen trees Having height of 4.00 metres or more (2) A detailed landscaping plan will have to be approved from the compulsorily Competent Authority with specifications as given in above table. (3) Norms for planting in all plots belonging to individual shall be as follows: (a) Minimum of three trees in every plot for plot size above 100 Square metres. (b) Selected trees should be more than 5.00 m in height and be suitable for local climate. (38) STRUCTURAL DESIGN AND SAFETY FEATURES: The structural design of foundation elements made of masonry, timber, plain concrete, reinforced concrete, pre-stressed concrete and structural steel, shall be carried out in accordance with Part-VI Structural Design, Section-1 Loads, Section 2 - Foundation, Section 3 - Wood, Section 4 - Masonry, Section 5 - Concrete, Section 6 - Steel of National Building Code of India, 2005 taking into consideration all relevant Indian Standards given below: (1) IS: 1893 (Part1) - 2002 "Criteria for Earthquake Resistant Design of Structures (Fifth Revision)". (2) IS: 13920-1993 "Ductile detailing of Reinforced Concrete Structures subject to Seismic Forces - Code of Practice" November 1993. (3) IS: 13828-1993 "Improving Earthquake Resistance of Low Strength Masonry Buildings" August 1993.[ II— 4] 79 (4) IS: 4326-2013 "Earthquake Resistant Design and Construction of Buildings – Code of Practice (Second Revision)". (5) IS: 13827-1993 "Improving Earthquake Resistance of Earthen Building Guidelines" October 1993. (6) IS: 13935-2009 "Seismic Evaluation, Repair and Seismic Strengthening of Buildings Guidelines". (7) For Protection of Landslide Hazard: (a) IS 14458 (Part 1): 1998 Guidelines for retaining wall for hill area: Part 1 Selection of type of wall. (b) IS 14458(Part 2): 1997 Guidelines for retaining wall for hill area : Part 2 Design of retaining / breast walls. (c) IS 14458 (Part 3): 1998 Guidelines for retaining wall for hill area: Part 3 Construction of dry-stone walls. (d) IS 14496 (Part 2): 1998 Guidelines for the preparation of landslide - Hazard zonation maps in mountainous terrains: Part 2 Macro-zonation. (8) Whenever an Indian Standard or the National Building Code of India is referred, the latest provision in the standard should be adhered to. (39) MATERIAL AND CONSTRUCTION METHODS: (1) Quality of Materials and Workmanship (a) All materials and workmanship shall be of good quality conforming generally to accepted standards of Public Works Department of Uttarakhand, Indian Standard Specifications and Code as included in Part V Building Materials and Part VII Constructional Practices and Safety of National Building Code of India. (b) All burrow pits dug in the course of construction and repair of buildings, roads, embankment and the like shall be deep and connected with each other in the formation of a drain directed towards the lowest level and properly sloped for discharge into a river, stream, channel or drain and no person shall create any isolated burrow pit which is likely to cause accumulation of water which shall breed mosquitoes. (2) New Materials and Design Methods (a) The provisions of these Bye-Laws are not intended to prevent the use of any material or method of design or construction not specifically prescribed by Bye- Law No. 39.1, provided any such alternative has been approved by BIS or any other statutory body. (b) Such alternatives may be approved provided that it is found that the proposed alternative is satisfactory and conforms to the provisions of relevant parts regarding material, design and construction and that material, method, or work offered is for the purpose intended, at least equivalent to that prescribed, in the Bye-Laws in quality, strength, compatibility, effectiveness, fire and water resistance, durability and safety. (40) ELECTRICAL SERVICES: The planning, design and installation of electrical installation, air conditioning installation and installation of lifts and escalators shall be carried out in accordance with Part VIII Building Services, Section-2 Electrical installations, Section-3 Air conditioning and Heating, Section-5 Installation of Lifts and Escalators of the National Building Code of India. (41) ENERGY CONSERVATION MEASURES: (1) Use of Compact Fluorescent Lamps and Electronic Chokes: (a) The use of incandescent lamps and conventional chokes in all new buildings, institutions constructed in Government sector, Government Aided sector, Boards and Corporations and Autonomous bodies is banned. (b) It will be mandatory that in these existing buildings the defective incandescent lamps and chokes when replaced would be replaced by only Compact Fluorescent Lamps (CFL), LED and electronic chokes. (c) The Competent Authority will effect necessary modification in the local demand to promote the use of Compact Fluorescent Lamps, LED and electronic chokes instead of conventional bulbs and chokes while releasing/sanctioning new connections/loads in such buildings. (2) All new cases may consider the following provisions of solar water heating systems for energy conservation: (a) An open space in the roof which receives direct sunshine; the roof shall have a load bearing capacity of at least 152.90 kg. per Square metres.80 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] (b) The building must have a provision for continuous water supply to the solar water heating system. (c) The building design should provide for an insulated pipeline from the heating system to all distribution points where hot water is required. (d) The recommended minimum capacity of installation shall not be less than 150 litres per day for each bathroom and kitchen subject to the maximum of 5% of the total roof area is utilized by the system. (e) Installation of Solar Assisted Water Heating Systems shall conform to BIS specification IS 12933. The solar collectors used in the system shall have the BIS certification mark. (3) Whenever hot water requirement is continuous, auxiliary arrangement either with electrical elements or oil- based systems of adequate capacity may be provided. (4) No new building in the following categories shall be sanctioned unless this installation has solar assisted water heating system: (a) Industries which use hot water for processing; (b) All hospitals and nursing homes; (c) All hostels, hotels, motels, guest houses and banquet halls; (d) Large canteens i.e. which serve more than 100 persons in a day; (e) Office building on a plot area of 15 Square metres or above; (f) Residential buildings on a plot area of 500 Square metres or above; (g) Residential schools and colleges; (5) Off Grid Roof Top Solar Power Plant at New Buildings: All buildings on plot size 200 Square metres or more, which are proposed to be constructed afresh, shall install Rooftop Solar Power installation, of adequate capacity, as per norms and parameters fixed by Ministry of New and Renewable Energy or its subordinate organizations, from time to time. (42) LIGHTNING PROTECTION OF BUILDING: The lightning protection for building shall be provided based on the provisions of Part III of the National Building Code of India. (43) PLUMBING SERVICE: The planning, design, construction and installation of water supply, drainage and sanitation and gas supply systems shall be in accordance with Part IX Plumbing Services, Section - 1 Water Supply, Section - 2 Drainage and Sanitation, Section - 3 Gas Supply of the National Building Code of India. (44) REQUIREMENTS OF WATER SUPPLY IN BUILDING: (1) The total requirements of water supply shall be calculated based on the Building Occupancy as follows and as per the National Building Code as amended time to time. (a) Residential Building: Five persons per tenement. (b) Other Buildings: No. of persons based on occupant block and floor area. (2) Storage of Water: Minimum provision should be made for storage of water to meet the daily requirements of the individuals using the building as follows: Table: Minimum Domestic storage capacities S.No. No. of floors Storage Capacity For premises occupied as tenements with common convenience 1 Floor 1 Nill 2 Floor 2 and above 500 litres per tenement For premises occupied as flats or blocks 3 Floor 1 Nill 4 Floor 2 and above 500 litres per tenement[ II— 4] 81 Note: 1. If the premises are situated at a place higher than the road level in front of the premises, storage at ground level shall be provided on the same lines as on upper floors 2. The above storage may be sanctioned to be installed provided that the total domestic storage calculated on the above basis is not less than the storage calculated on the number of down-take fittings according to the scale given below - Down – take taps : 70.00 litres each - Showers : 135.00 litres each - Bathtubs : 200.00 litres each (45) RAIN WATER HARVESTING AND GROUND WATER REGULATIONS: (1) Water harvesting through storage of water runoff including rain water in all buildings on plots of 100.00 Square metres and above will be mandatory. (2) Adoption of roof top rain water harvesting system is mandatory for all residential/ educational/institutional/hotel building/industrial and commercial establishments, which have plot size more than 200.00 Square metres and more. (3) The plans submitted shall indicate the system of storm water drainage along with points of collection of rainwater in surface reservoirs or in recharge wells. These provisions will be applicable as per the Public Notice(s) of Central Ground Water Authority issued from time to time. (4) Undertaking of any operations connected with drilling, cleaning, construction or rehabilitation of ground water abstraction structures and related works including installation of pumps cannot be taken up without prior permission of the Cantonment Board. (5) Drilling contractors or Agencies/Plot occupiers are required to take prior permission for works connected with drilling, cleaning, boring and installation of pumps. (6) The Authority shall ensure that no drilling activity is undertaken without prior approval and is authorized to take action against offenders by seizing of drilling rig, sealing of tube well and disconnection of electric supply to the energized tube well. (46) REQUIREMENTS OF SANITARY FITTINGS: (1) To ensure optimization of water the following measures shall be adopted in case of all new building sanction where plot size is more than 200 Square metres on a case to case basis as decided by the Competent Authority: (a) Use of low dual flush capacity cisterns in water closets instead of the normal 10 litres capacity. (b) Use of waterless urinals in all public buildings. (c) Provision of storage and use of recycled water for toilet flushing where the minimum discharge in the building/complex is 10 litres /minute or more. (2) The sanitary fittings and installations for different occupancies shall be as per National Building Code as amended from time to time. (47) SEWAGE PLAN: Where a septic tank is used for sewage disposal, the location, design, and construction of septic tank shall conform to requirements of Part 9 ‘Plumbing Services, Section 1 Water Supply, Drainage and Sanitation (Including Solid Waste Management)’ of NBC. (1) Location of the Septic Tanks and Subsurface Absorption Systems: A sub-soil dispersion system shall not be closer than 18 metre from any source of drinking water, such as well, to mitigate the possibility of bacterial pollution of subsurface water. It shall also be as far removed from the nearest habitable building as economically feasible but not closer than 6 metre, to avoid damage to the structures. (2) Requirements:82 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] a) Dimensions of septic tanks - Septic tanks shall have a minimum width of 0.75 metre, a minimum depth of 1 metre and a minimum liquid capacity of 1m3. The length of tanks shall be 2 to 4 times the width; b) Septic tanks may be constructed of brickwork, stone masonry, concrete or other suitable materials as approved by the Authority; c) Under no circumstances shall effluent from a septic tank be allowed into an open channel drain or body of water without adequate treatment; d) The minimum nominal diameter of the pipe shall be 100 millimetres. Further, at junctions of pipes in manholes, direction of flow from a branch connection shall not make an angle exceeding 45° with the direction of flow in the main pipe; e) The gradients of land drains, under-drainage as well as the bottom of dispersion trenches and soakways shall be between 1:300 and 1:400; f) Every septic tank shall be provided with ventilating pipe of at least 50 millimetres diameter. The top of the pipe shall be provided with a suitable cage of mosquito proof wire mesh. The ventilating pipe shall extend to a height which would cause no smell nuisance to any building in the area. Generally, the ventilating pipe may extend to a height of about 2 metre, when the septic tank is at least 15 metre away from the nearest building and to a height of 2 m above the top of the building when it is located closer than 15 metre; g) When the disposal of septic tank effluent is to a seepage pit, the seepage pit may be of any suitable shape with the least cross-sectional dimension of 0.90 metre and not less than 1.00 metre in depth below the invert level of the inlet pipe. The pit may be lined with stone, brick or concrete blocks with dry open joints which should be backed with at least 75 millimetres of clean coarse aggregate. The lining above the inlet level should be finished with mortar. In the case of pits of large dimensions, the top portion may be narrowed to reduce the size of the RCC cover slabs. Where no lining is used, specially near trees, the entire pit should be filled with loose stones. A masonry ring may be constructed at the top of the pit to prevent damage by flooding of the pit by surface runoff. The inlet pipe may be taken down a depth of 0.90 metre from the top as an anti-mosquito measure; and h) When the disposal of the septic tank effluent is to a dispersion trench, the dispersion trench shall be 0.50 metre to 1.00 metre deep and 0.30 metre to 1.00 metre wide excavated to a slight gradient and shall be provided with 150 millimetres to 250 millimetres of washed gravel or crushed stones. Open jointed pipes placed inside the trench shall be made of unglazed earthenware clay or concrete and shall have a minimum internal diameter of 75 millimetres to 100 millimetres. Each dispersion trench shall not be longer than 30 metre and trenches shall not be placed closer than 1.80 metre. CHAPTER VII SAVINGS, PANALTIES AND INTERPRETATION (48) SAVINGS: The existing building approved by the Board shall remain valid and the buildings erected as per the building plans approved by the Board before the date of entry into force of this Bye-laws shall also be valid. (49) PENALTIES: Any person who contravenes any of the provisions of these bye-laws shall be punishable as per the provisions of the Act. (50) MOD GUIDELINES: The Ministry of Defence guidelines issued from time to time regarding NOC for construction of buildings close to defence establishments will be followed in approval of building plans. (51) INTERPRETATION TO BE IN CONSONANCE WITH THE ACT, APPLICABLE RULES AND POLICIES: Notwithstanding anything contained herein, the provisions of these Building Bye-Laws shall at all times be in consonance and within the provisions of the Act, and other statutory rules under the Act. Wherever any discrepancy or ambiguity arises, the Act, shall apply and shall prevail. The provisions of the Act, are in-built into these Bye-Laws and shall be read as part of the Bye-Laws for understanding and applying the Bye-Laws. Similarly, the terms of lease, terms of old grant and such other terms as per the[भागII—ख(cid:7003) ड4] भारत का राजप(cid:7074) : असाधारण 83 existing policies or any policy issued in this regard from time to time shall prevail and the Building Bye- Laws now promulgated shall be within the meaning of these policies and shall not be in any way contrary to the said policy terms. To the said extent, the terms of these Building Bye-Laws are conditional. [F. No. 124/CBC/Building Bye-Laws/] HIMANSHU SAMANT, (I.D.E.S) ,Chief Executive Officer Cantonment Board, Clement Town FORM A: CERTIFICATE REGARDING SAFETY FROM NATURAL HAZARDS AND STRUCTURAL SAFETY (To be submitted by Structural Engineer and applicant through e-Chhawani portal) To The Chief Executive Officer, Office of Cantonment Baord, Sir/Madam I hereby certify that the erection/re-erection or addition/alteration in building No.……….. ……………………… on / in plot No. .………………….in block No... …………………. situated at road / street.….……………………………. survey / GLR Sy. No. …………………………. of Clement Town Cantonment has been undertaken by me. I certify that the building plans submitted for approval adhere to the safety requirements of Bye laws. It is certified that the structural design including safety from natural hazards based on soil conditions has been duly incorporated in the design of the building and these provisions shall be adhered to during the construction. 1, being a Structural Engineer, certify that the additions/alterations satisfy the requirements of structural stability and all such alterations, repairs involving walls, columns, beams, roof, footings, foundations etc., are covered under the provisions of building Bye-Laws requiring compliance. Signature of Structural Engineer………………………………… Name in block letters…………………………………………….. Address ……………………………………………. …………………………………………….. …………………………………………….. Signature of Applicant……………………………………………. Name in block letters…………………………………………….. Address …………………………………………… …………………………………………… …………………………………………… Date………………………84 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] FORM B : CERTIFICATE FOR SUPERVISION (To be submitted by Architect / Civil Engineer / Structural Engineer and applicant through e- Chhawani portal) To The Chief Executive Officer, Office of Cantonment Board, Clement Town. Sir/Madam, I hereby certify that the erection / re-erection or addition/alteration in building No. .on / in plot No ..in block No. situated at road / street survey/GLR Sy. No . shall be carried out under my supervision and I certify that all materials (type and grade) and the workmanship of the work shall be generally in accordance with the general specification submitted along with the building application and that the work shall be carried out according to the sanctioned plan. I shall be responsible for the execution of the work in all respects. Signature of Architect/Civil Engineer /Structural Engineer ... Name of Architect/Civil Engineer /Structural Engineer ... License No. of Architect/Civil Engineer /Structural Engineer ... Signature of Architect/Civil Engineer/Structural Engineer. . Signature of Applicant ... Name in block letters ..... Address . . Date ..[ II— 4] 85 FORM C: INDEMNITY BOND FOR BASEMENT (To be submitted by applicant through e-Chhawani portal) TO BE SUBMITTED ON NON-JUDICIAL STAMP PAPER OF APPROPRIATE VALUE DULY ATTESTED BY THE OATH COMMISSIONER/MAGISTRATE FIRST CLASS Indemnity bond is executed by Shri S/o Shri R/o .hereby called Applicant of plot No. in . of Clement Town Cantonment in favor of the Competent Authority. Whereas the Applicant has submitted the plan of basement and whereas the Applicant has represented to the Competent Authority that if sanction is granted for the construction of the said basement the Applicant shall indemnify the Competent Authority of any loss at time of digging of foundation of the said basement or in the course of construction of the basement or even thereafter. And whereas the said Applicant has further agreed to indemnify the Competent Authority for any claims put up against the Authority either by way of damage, compensation or in any other way in case the Authority is required to pay any such amount to any person or the Applicant or Applicants of the adjoining properties. The Applicant hereby agrees/free and undertake to indemnify the Authority to pay the full extent of the amount the Authority may require to pay to the extent hereinabove mentioned. The Applicants further undertakes/undertake and agree to indemnify the Authority for any such amount the Competent Authority may require to pay/free either by way of compensation or damage or any other amount and further undertake to indemnify the authority of all cost and expenses that the Authority may require to defend such action in any court of law. The Applicant undertakes/undertake that no excavation shall be carried out beyond permissible boundaries of plot. Any damage occurring during or due to excavation made at site to public sewer, water drains shall be made good by the Applicant. In consideration of the above matter, undertaking and indemnity given by the said Applicant the Authority hereunder in this behalf grant the sanction to construct the basement to the said Applicants. In witness hereof, the Applicant abovementioned puts/put their hands and seal to the said indemnity bond on this . day of . (Executants) (1) . (Applicant) (2) . Witness: (1) . (2) . Date86 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] FORM D: NOTICE FOR COMMENCEMENT OF WORK To The Chief Executive Officer, Office of Cantonment Board, Clement Town. Sir/Madam, I hereby state that the erection / re-erection or addition / alteration in / on building No. on / in Survey No. . Road Clement Town Cantonment will be commenced on . as per your permission granted vide office letter No. ... dated . under the supervision of . Architect/ Civil Engineer / Structural Engineer / in accordance with sanctioned plans. Signature of Applicant Name of Applicant . (IN BLOCK LETTERS) Address of Applicant . .. .. .. Date[ II— 4] 87 FORM E : NOTICE ON COMPLETION OF BUILDING (Section 242 of the Act) To The Chief Executive Officer, Office of Cantonment Board, Clement Town. Sir/Madam, 1. We hereby certify that the erection/re-erection of building or addition/alteration in building on (address) has been supervised by the undersigned and is strictly in accordance with the plan sanctioned vide letter No dated .No provisions of the building Bye-Laws have been transgressed. The work has been completed to our satisfaction and the workmanship and materials used strictly adhere to the general and detailed specifications. Drainage/sanitation/water supply works have been executed as per building byelaws and sanctioned plan. No provision of the Building Bye-Laws and conditions prescribed or orders issued there under have been transgressed in the course of the work. The building is fit for use for which it has been erected/re-erected or altered/constructed and enlarged. 2.Certificates: Certified that the building/s has/have been constructed according to the Sanctioned Plan and structural design which incorporate the provisions of structural safety as specified in relevant prevailing IS Codes/Standards/Guidelines. Certified that water harvesting as well as waste water re-cycling systems have been provided as per the sanctioned building plan. It is also certified that construction has been done under our supervision and guidance and adheres to the drawings submitted and the records of supervision maintained by us. 3. Permission to occupy or use the building may be granted. 4. Any subsequent change from completion drawings will be the responsibility of the Applicant(s). Signature of Applicant .. Name .. Address .. Signature of Supervisory Architect .. License No. .. Name .. Address .. Signature of Structural Engineer .. License No. .. Name . Address .. Date88 THEGAZETTEOFINDIA :EXTRAORDINARY [PART II—SEC.4] FORM F : CERTIFICATE FOR COMPLETION-CUM-OCCUPANCY OF BUILDING (Section 246 of the Act) To Sir/Madam, With reference to your notice of completion dated , I hereby certify that building, as per description below at .............................................................................................. (address) whose plans were sanctioned vide sanction No. dated ... has been inspected to ascertain if the same conforms to building bye-laws in respect of the structural safety, hygienic and sanitary conditions inside and in the surroundings. It is declared fit for occupation. The details of the construction work completed are as follows: Brief description of each block with area: 1. .. 2. .. 3. .. 4. .. 5. .. 6. .. 7. .. 8. .. 9. .. 10. .. 11. .. 12. .. Letter No. Office Stamp Date . Chief Executive Officer Office of Cantonment Board Clement Town Uploaded by Dte. of Printing at Government of India Press, Ring Road, Mayapuri, New Delhi-110064. and Published by the Controller of Publications, Delhi-110054.