Official Gazette Notification Text
Official Transcriptरजिस्ट्री स.ं डी.एल.- 33004/99 REGD. No. D. L.-33004/99 सी.जी.-डी.एल.-अ.-18092026-276323 CG-DLxx-xEG-I1D8H0x9x2x0 26-276323 xxxGIDExxx असाधारण EXTRAORDINARY भाग II—खण् ड 3—उप-खण्ड (i) PART II—Section 3—Sub-section (i) प्राजधकार स ेप्रकाजित PUBLISHED BY AUTHORITY स.ं 741] िई दिल्ली, मगं लर्ार, जसतम्ब र 15, 2026/भाद्र 24, 1948 No. 741] NEW DELHI, TUESDAY, SEPTEMBER 15, 2026/BHADRA 24, 1948 उपभोक्त ा...
रजिस्ट्री स.ं डी.एल.- 33004/99 REGD. No. D. L.-33004/99 सी.जी.-डी.एल.-अ.-18092026-276323 CG-DLxx-xEG-I1D8H0x9x2x0 26-276323 xxxGIDExxx असाधारण EXTRAORDINARY भाग II—खण् ड 3—उप-खण्ड (i) PART II—Section 3—Sub-section (i) प्राजधकार स ेप्रकाजित PUBLISHED BY AUTHORITY स.ं 741] िई दिल्ली, मगं लर्ार, जसतम्ब र 15, 2026/भाद्र 24, 1948 No. 741] NEW DELHI, TUESDAY, SEPTEMBER 15, 2026/BHADRA 24, 1948 उपभोक्त ा मामल,े खाद्य और सार्िव जिक जर्तरण मत्रं ालय (उपभोक्त ा मामल ेजर्भाग) अजधसचू िा िई दिल् ली, 15 जसतम्बर, 2026 सा.का.जि. 809(अ).—केंद्रीय सरकार, जर्जधक मापजर्ज्ञाि अजधजियम, 2009 (2010 का 1) की धारा 52 की उपधारा (2) के खडं (ग), खंड (च), खंड (ि), खडं (झ) और खंड (ध) के साथ पठित उपधारा (1) द्वारा प्रित् त िजियों का प्रयोग करते हुए जिम्नजलजखत जियम बिाती ह,ै अथावत:् -
1.सजं िप्त िाम और प्रारंभ.– (1) इि जियमों का संजिप्त िाम जर्जधक मापजर्ज्ञाि (साधारण) पााँचर्ा संिोधि जियम, 2026 ह।ै
(2) य ेरािपत्र में प्रकािि की तारीख से एक सौ अस्ट्सी दिि के पश्चात ्प्रर्ृत्त होंगे ।
2. जर्जधक मापजर्ज्ञाि (साधारण) जियम, 2011 की आिर्ीं अिुसूची में भाग XIII के पश्चात, जिम्नजलजखत भाग रखा िाएगा, अथावत:् - 7077 GI/2026 (1)2 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] “भाग- XIV सक्रिय विधतु ऊर्ा ा मीटर भाग 1: मापविज्ञान और तकनीकी आिश्यकताए ँ
1. मीटर और उनके घटकों की पररभाषाए:ँ -
(1) विद्यतु मीटर – ऐसा उपस्कर वर्सका उद्देश्य समय के साथ पॉिर को र्ोड़कर लगातार विद्युत की ऊर्ाा को मापना और पररणाम को स्टोर करना ह।ै स्पष्टीकरण: 'लगातार' शब्द में ऐसे मीटर भी शावमल हो सकते ह ैं वर्नकी सैंपललिंग दर इतनी अवधक हो क्रक िे इस भाग की आिश्यकताओं को पूरा कर सकें;
(2) इिंटरिल मीटर.– स े ऐसा विद्यतु का मीटर अवभप्रेत ह ै र्ो पहल े स े तय समय-अिंतराल में मापे गए नतीर्ों को क्रदखाता और स्टोर करता ह;ै
(3) प्रीपमे टें मीटर.– स े ऐसा विद्युत का मीटर अवभप्रेत ह ै वर्ससे पहले से तय मात्रा तक विद्युत की सप्लाई की र्ा सके। रटप्पण 1: ऐसा मीटर लगातार ऊर्ाा को मापता ह ै और मापी गई ऊर्ाा को स्टोर करता और क्रदखाता है;
(4) मल्टी-टैररफ मीटर, मल्टी-रेट मीटर.– स े ऐसा विद्युत का मीटर अवभप्रेत ह ै र्ो विद्युत की ऊर्ा ा को मापता और क्रदखाता ह,ै र्हाँ ऊर्ाा के वलए एक से ज़्यादा टैररफ दरें होती ह।ैं रटप्पण: टैररफ दर समय, लोड या क्रकसी अन्य मात्रा के आधार पर तय की र्ा सकती है;
(5) डायरेक्ट कनक्े टेड मीटर.– से ऐसा मीटर अवभप्रेत ह ै वर्से मापे र्ान े िाले सर्काट से सीधे र्ोड़कर इस्तेमाल क्रकया र्ाता ह,ै वर्समें उपस्करट्ािंसफॉमार र्ैसे बाहरी वडिाइस का इस्तेमाल नहीं होता;
(6) ट्ासिं फॉमरा पररचावलत मीटर.– से ऐसा मीटर अवभप्रेत ह ै वर्से एक या ज़्यादा बाहरी उपस्करट्ािंसफॉमार के साथ इस्तेमाल क्रकया र्ाता ह;ै
(7) इलक्े ट्ोमकै ेवनकल मीटर.– से ऐसा मीटर अवभप्रेत ह ै वर्समें क्रफक्स्ड कॉइल में बहने िाली करिंट, घूमने िाले किंडलक्टिंग एवलमेंट, आमतौर(ए) वडस्क(एस) में उत्पन्न हुई करिंट के साथ प्रवतक्रिया करती ह,ै वर्सस ेमापी र्ान ेिाली उर्ाा के अनुपात में उसमें गवत होती ह;ै[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 3
(8) स्टैरटक मीटर.– से ऐसा मीटर अवभप्रेत ह ै वर्समें विद्युत और िोल्टेर् सॉवलड-स्टेट (इलेक्ट्ॉवनक) एवलमेंट्स पर काम करते ह,ैं ताक्रक मापी र्ाने िाली उर्ाा के अनुपात में आउटपुट वमल सके;
(9) मापन ेिाला एवलमटें .– मीटर का िह वहस्सा र्ो विद्यतु और िोल्टेर् को पािर और/या उर्ाा के अनुपात में वसग्नल में बदलता ह।ै रटप्पण: मापने िाला एवलमेंट इलेक्ट्ोमैग्नेरटक, इलेवक्ट्कल या इलेक्ट्ॉवनक वसद्ातिं पर आधाररत हो सकता ह;ै
(10) करिंट सर्काट.– मीटर के अिंदर के कनेक्शन और मापने िाले वहस्से का िह भाग वर्ससे उस सर्काट का करिंट बहता ह ै वर्ससे मीटर र्ुड़ा होता है;
(11) िोल्टेर् सर्काट.– मीटर के अिंदर के कनेक्शन, मापने िाले वहस्स े का भाग और स्टैरटक मीटर के मामल ेमें, पािर सप्लाई का िह भाग, वर्से उस सर्काट का िोल्टेर् वमलता ह ै वर्ससे मीटर र्ुड़ा होता है;
(12) इिंवडकेटटिंग वडिाइस (वडस्प्ल)े – स े मीटर का िह वहस्सा अवभप्रेत ह ैर्ो माप के नतीर्ों को लगातार या ज़रूरत पड़ने पर क्रदखाता ह;ै रटप्पण: इिंवडकेटटिंग वडिाइस का इस्तेमाल दसू री ज़रूरी र्ानकारी क्रदखाने के वलए भी क्रकया र्ा सकता ह।ै
(13) रवर्स्टर – स े मीटर का िह वहस्सा अवभप्रेत ह ै र्ो मापे गए मान को स्टोर करता ह।ै रटप्पण: रवर्स्टर एक इलेक्ट्ोमैकेवनकल वडिाइस या इलेक्ट्ॉवनक वडिाइस हो सकता ह ै और यह इिंवडकेटटिंग वडिाइस का ही एक वहस्सा हो सकता ह;ै
(14) प्राइमरी रेटेड रवर्स्टर (ट्ासिं फॉमरा पररचावलत मीटर के वलए)– से िह रवर्स्टर अवभप्रेत ह ै वर्समें इस्तेमाल क्रकए गए उपस्करट्ािंसफॉमार के कारण स्केल फैक्टर को इस तरह ध्यान में रखा र्ाता ह ैक्रक उपस्करट्ािंसफॉमार के प्राइमरी साइड पर मापी गई उर्ाा क्रदखाई दे;
(15) रवर्स्टर मल्टीप्लायर– से िह कॉन्स्टेंट अवभप्रेत वर्ससे रवर्स्टर रीलडिंग को गुणा करके मीटर से मापी गई उर्ाा का मान पता क्रकया र्ाता ह;ै
(16) मीटर कॉन्स्टेंट– से िह मान अवभप्रेत ह ैर्ो मीटर द्वारा दर् ा की गई उर्ाा और टेस्ट आउटपुट के सिंबिंवधत मान के बीच सिंबिंध बताती ह;ै4 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)]
(17) टेस्ट आउटपुट– से िह वडिाइस अवभप्रेत ह ैवर्सका इस्तेमाल मीटर की टेलस्टिंग के वलए क्रकया र्ा सकता ह,ै र्ो पल्स देता ह ै या मीटर द्वारा मापी गई उर्ाा के वहसाब से पल्स देने का साधन उपलब्ध कराता ह;ै
(18) एडर्स्टमटें वडिाइस– से मीटर में शावमल िह वडिाइस या फिंक्शन अवभप्रेत ह ै र्ो त्रुरट कि ा को वशफ्ट करने की सुविधा देता ह,ै ताक्रक (इिंवडकेशन की) त्रुरटयों को अवधकतम अनुमेय त्रुरट सीमा के भीतर लाया र्ा सके;
(19) सहायक उपस्कर- स े एक विशेष काय ा करन े के वलए बनाया गया उपकरण, अवभप्रेत ह ै र्ो सीधे माप पररणामों को विस्तृत करन,े प्रसाररत करन े या प्रदर्शात करने में शावमल होता ह।ै रटप्पण: एक सहायक उपस्करमीटर के आधारभूत मापविज्ञान काया का वहस्सा नहीं है; और
(20) सब-असबें ली- से क्रकसी उपस्करका िह भाग अवभप्रते ह ै वर्सका स्ियिं का पहचानने योग्य काया हो।
2. मापविज्ञान विशषे ताए:िं -- वनम्नवलवखत विशेषताएिं इस प्रकार ह,ैं अथाता ्:--
(1) करिंट (I) .– मीटर से बहने िाली इलेवक्ट्क करिंट का मान स्पष्टीकरण: इस वहस्से में 'करिंट' शब्द का मतलब आर.एम.एस. (रूट मीन स्वायर) मान से ह,ै र्ब तक क्रक कुछ और न बताया गया हो।
(2) स्टार्टिंग करिंट (I ) .– यह करिंट की िह सबसे कम मान ह ै र्ो विवनमााता बताता है, वर्स पर मीटर को यूवनटी पािर st फैक्टर पर और पॉली-फेज़ मीटर के मामले में बैलेंस्ड लोड के साथ विद्युत उर्ाा को ररकॉडा करना चावहए।
(3) न्यनू तम करिंट (I ) .– करिंट का िह न्यूनतम मान वर्स पर विवनमााता द्वारा मीटर के सटीकता सिंबिंधी आिश्यकताओं min को पूरा करने का वनदेश क्रदया गया ह।ै
(4) ट्ाविं र्शनल करिंट (I) .– करिंट का िह मान और उससे अवधक का मान वर्स पर विवनमााता के अनसु ार मीटर की त्रुरट, tr मीटर की एक्यूरेसी क्लास के वलए तय सबसे कम अवधकतम अनुमेय त्रुरट सीमा के भीतर रहती ह।ै
(5) अवधकतम करिंट (I ) .– करिंट का िह अवधकतम मान वर्स पर विवनमााता द्वारा मीटर के सटीकता सिंबिंधी मानकों max को पूरा करने का वनदेश क्रदया गया ह।ै
(6) िोल्टेर् (U) .– मीटर को सप्लाई क्रकए र्ाने िाले विद्युत िोल्टेर् का मान रटप्पण: इस भाग में "िोल्टेर्" पद आर.एम.एस. (रूट मीन स्वायर) मान ह,ै र्ब तक क्रक अन्यथा न बताया गया हो।
(7) नॉवमनल िोल्टेर् (U ) .– मीटर के सामान्य कामकार् के वलए विवनमााता द्वारा बताया गया िोल्टेर्। nom रटप्पण: अलग-अलग िोल्टेर् रेंर् पर काम करने के वलए वडज़ाइन क्रकए गए मीटरों के वलए कई नॉवमनल िोल्टेर् मान हो सकती ह।ैं[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 5
(8) फ़्रीवेंसी (f) .– मीटर को सप्लाई क्रकए र्ान े िाले िोल्टेर् (और करिंट) की फ़्रीवेंसी।
(9) नॉवमनल फ़्रीवेंसी (f ) .– मीटर के सामान्य सिंचालन के वलए विवनमााता द्वारा बताई गई िोल्टेर् (और करिंट) की nom फ़्रीवेंसी।
(10) हामोवनक.– वसग्नल का िह वहस्सा वर्सकी फ़्रीवेंसी, वसग्नल की फिंडामेंटल फ़्रीवेंसी का पूणािंक गुणर् होती ह।ै रटप्पण: फिंडामेंटल फ़्रीवेंसी आमतौर पर नॉवमनल फ़्रीवेंसी(f ) होती ह।ै nom
(11) सब-हामोवनक.– िह फ़्रीवेंसी र्ो वसग्नल की फिंडामेंटल फ़्रीवेंसी का एक पूणािंक अिंश होती है, अथाात् फिंडामेंटल फ़्रीवेंसी का 1/n गुना, र्हाँ n, 1 से बड़ा एक पूणािंक ह।ै
(12) हामोवनक नबिं र.– हामोवनक की पहचान करने के वलए इस्तेमाल क्रकया र्ाने िाला एक पूणािंक निंबर। रटप्पण: हामोवनक निंबर, हामोवनक की फ़्रीवेंसी और वसग्नल की फिंडामेंटल फ़्रीवेंसी का अनुपात होता ह।ै
(13) वडस्टॉशना फैक्टर (d) .– हामोवनक किंटेंट के आर.एम.एस. मान और फिंडामटें ल टमा के आर.एम.एस. मान का अनुपात। रटप्पण 1: हामोवनक किंटेंट, उदाहरण के वलए, नॉन-साइनसु ोइडल अल्टरनेटटिंग वािंरटटी से उसके फिंडामेंटल टमा को घटाकर प्राप्त क्रकया र्ाता ह।ै रटप्पण 2: वडस्टॉशान फैक्टर को आमतौर पर प्रवतशत के रूप में व्यक्त क्रकया र्ाता ह।ै यह टीएचडी, टोटल हामोवनक वडस्टॉशान के बराबर होता ह।ै
(14) पािर फैक्टर (PF) .– एवक्टि पािर और अपेरेंट पािर का अनुपात । रटप्पण: साइनसोइडल और या तो लसिंगल-फेज़ या वसमेरट्कल थ्री-फेज़ वस्थवतयों म,ें पािर फैक्टर = cos Φ = िोल्टेर् U और करिंट I के बीच फेज़ अिंतर Φ का कोसाइन।
(15) एवक्टि पािर.– िह दर वर्स पर एनर्ी का ट्ािंसवमशन होता ह।ै रटप्पण: इलेवक्ट्कल वसस्टम में एवक्टि पािर को इिंस्टैंटेवनयस पािर के टाइम मीन के तौर पर मापा र्ाता है; इसे हर पल िोल्टेर् और करिंट के गुणनफल के रूप में गणना की र्ाती है:
p(t) =u(t)⋅i(t) यहाँ:6 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] u इिंस्टैंटेवनयस िोल्टेर् ह,ै i इिंस्टैंटेवनयस करिंट ह,ै p इिंस्टैंटेवनयस पािर ह।ै साइनसोइडल वस्थवतयों में, एवक्टि पािर, करिंट और िोल्टेर् के आर.एम.एस. मानों और उनके बीच के फेज़ एिंगल के कोसाइन का गुणनफल होती ह,ै वर्सकी गणना हर फेज़ के वलए की र्ाती ह।ै इसे आमतौर पर kW में बताया र्ाता ह:ै P=U ⋅I ⋅ cos Φ.
r.m.s r.m.s
(16) एवक्टि एनर्ी.– समय के साथ इिंटीग्रेटेड एवक्टि पािर रटप्पण 1: E(T) = = यहाँ:
E सक्रिय ऊर्ा ा ह।ै अन्य प्रतीक 2(2)(15) में पररभावषत ह ैं रटप्पण 2: सक्रिय ऊर्ाा आमतौर पर kWh या MWh में व्यक्त की र्ाती ह।ै माप की इकाइयों पर आिश्यकताओं के वलए 3(1) देखें।
(17) सिंकेत की सापेक्ष त्रुरट – सिंकेत में से रेफरेंस वािंरटटी मान को घटाकर, उसे रेफरेंस वािंरटटी मान से भाग देना। रटप्पण 1: सापेक्ष त्रुरट को आमतौर पर रेफरेंस वािंरटटी मान के प्रवतशत के रूप में बताया र्ाता ह।ै
(18) अवधकतम अनुमेय त्रुरट (एमपीई) – क्रकसी खास माप, मापने िाले उपस्करया मापने िाले वसस्टम के वलए विवनदेश या विवनयमों द्वारा अनुमेय, ज्ञात रेफरेंस वािंरटटी मान के सिंदभा में माप की त्रुरट का अवधकतम मान। रटप्पण 1: आमतौर पर, "अवधकतम अनुमेय त्रुरट" या "त्रुरट की सीमा" शब्द का इस्तेमाल तब क्रकया र्ाता ह ै र्ब दो अवधकतम मान होते ह।ैं रटप्पण 2: "सवहष्णुता" शब्द का उपयोग "अवधकतम अनुमेय त्रुरट" को वनर्दाष्ट करने के वलए नहीं क्रकया र्ाना चावहए रटप्पण 3: इस भाग में, अवधकतम अनुमेय त्रुरट का आधार अवधकतम अनुमेय त्रुरट और अवधकतम अनुमेय त्रुरट बदलाि का एक सिंयोर्न ह ै र्सै ा क्रक अनुलग्नक क में िर्णात ह।ै रटप्पण 4: इस भाग के अनप्रु योग के वलए, "विवनदेशों या विवनयमों" स े ह:ै इस भाग में वनवहत प्रािधान और "माप उपकरण" और "माप प्रणाली" पद से ह:ै विद्युत मीटर अवभप्रेत ह ै ।
(19) आधार अवधकतम अनमु ेय त्रुरट एमपीई.– इस अवधसूचना के तहत मीटर की रीलडिंग में त्रुरट की िह अवधकतम सीमा र्ो तब अनुमेय होती ह,ै र्ब करिंट और पािर फैक्टर को वनधााररत पररचालन वस्थवतयों के तहत क्रदए गए अिंतराल के भीतर बदला र्ाता ह,ै और र्ब मीटर को अन्य मामलों में रेफरेंस वस्थवतयों पर चलाया र्ाता ह।ै[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 7 रटप्पण: इस भाग में, अवधकतम अनुमेय त्रुरट, आधार अवधकतम अनुमेय त्रुरट और अवधकतम अनुमेय त्रुरट बदलाि का वमश्रण ह,ै र्सै ा क्रक अनुलग्नक क में बताया गया ह।ै
(20) अवधकतम अनुमेय त्रुरट बदलाि.– मीटर के सिंकेत त्रुरट में बदलाि का िह अवधकतम मान, वर्सकी अनुमवत यह अवधसूचना दते ा ह,ै र्ब क्रकसी एक प्रभाि डालन े िाले कारक को रेफरेंस वस्थवतयों में उसके मान से बदलकर वनधााररत पररचालन वस्थवतयों के दायरे में बदला र्ाता ह।ै रटप्पण 1: प्रभाि डालने िाले हर कारक के वलए एक सबिं िंवधत अवधकतम अनुमेय त्रुरट बदलाि होता ह।ै रटप्पण 2: इस अवधसूचना में, अवधकतम अनुमेय त्रुरट, आधार अवधकतम अनुमेय त्रुरट और अवधकतम अनुमेय त्रुरट बदलाि का वमश्रण ह,ै र्ैसा क्रक अनुलग्नक क में बताया गया ह।ै
(21) आतिं ररक त्रुरट.– क्रकसी मापक यिंत्र की िह त्रुरट, र्ो सिंदभा वस्थवतयों में वनधााररत की र्ाती ह।ै
(22) प्रारिंवभक आिंतररक त्रुरट.– क्रकसी मापक यिंत्र की िह आिंतररक त्रुरट, र्ो प्रदशान परीक्षणों और रटकाऊपन के मूल्यािंकन से पहले वनधााररत की र्ाती ह।ै
(23) प्रभाि मात्रा.– िह मात्रा र्ो प्रत्यक्ष माप में, िास्ति में मापी र्ाने िाली मात्रा को तो प्रभावित नहीं करती, लेक्रकन सिंकेत और माप के पररणाम के बीच के सिंबिंध को प्रभावित करती ह।ै रटप्पण 1: 'प्रभाि मात्रा' के कॉन्सेप्ट में िे मान शावमल हैं र्ो माप के मानक, रेफरेंस मटीररयल और रेफरेंस डेटा से र्ुड़ी होती ह,ैं वर्न पर माप का नतीर्ा वनभार कर सकता ह।ै साथ ही, इसमें माप िाले उपस्करमें थोड़े समय के वलए होन ेिाले उतार-चढाि र्ैसी घटनाएिं और आस-पास का तापमान, बैरोमीटर का दबाि और नमी र्ैसी मात्राएिं भी शावमल ह।ैं
(24) प्रभाि कारक.– प्रभाि डालने िाली ऐसी मात्रा वर्सका मान क्रकसी मापक यिंत्र की वनधााररत पररचालन वस्थवतयों के दायरे में आता ह।ै
(25) व्यिधान.– प्रभाि डालने िाली ऐसी मात्रा वर्सका मान इस अवधसूचना में बताई गई सीमाओं के भीतर तो ह,ै लेक्रकन मापक यिंत्र की वनधााररत पररचालन वस्थवतयों के दायरे से बाहर ह।ै रटप्पण: यक्रद क्रकसी प्रभाि डालने िाली मात्रा के वलए वनधााररत पररचालन वस्थवतयािं नहीं बताई गई हैं, तो उस मात्रा को व्यिधान माना र्ाएगा।
(26) वनधााररत पररचालन वस्थवत – िह पररचालन वस्थवत वर्से माप के दौरान पूरा क्रकया र्ाना आिश्यक ह ैताक्रक मापन उपस्करया मापन प्रणाली अपने वडज़ाइन के अनसु ार काम कर सके।8 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] रटप्पण 1: वनधााररत पररचालन वस्थवत आमतौर पर मापी र्ा रही मात्रा और क्रकसी भी प्रभाि डालने िाली मात्रा के वलए मानों का अिंतराल बताती हैं। रटप्पण 2: इस अवधसूचना के सिंदभा में, "माप उपकरण" और "माप प्रणाली" पदों से ह:ै विद्युत का मीटर अवभप्रेत ह ै ।
(27) सिंदभा वस्थवत.– क्रकसी माप उपस्करया माप प्रणाली के कायावनष्पादन का मूल्यािंकन करने या माप के पररणामों की तुलना करन े के वलए वनधााररत पररचालन वस्थवत अवभप्रेत ह।ै रटप्पण 1: सिंदभा पररचालन वस्थवतयािं मापी र्ाने िाली मात्रा और प्रभाि डालने िाली मात्राओं के मानों के अिंतराल को वनर्दाष्ट करती ह।ैं रटप्पण 2: इस अवधसूचना के अनुप्रयोग के वलए, "माप उपकरण" और "माप प्रणाली" पदों से ह:ै विद्यतु का मीटर अवभप्रेत ह।ै
(28) सटीकता श्रेणी.– माप उपकरणों या प्रणावलयों की िह श्रेणी र्ो बताई गई मापविज्ञान आिश्यकताओं को पूरा करती ह।ै इसका उद्देश्य तय पररचालन वस्थवतयों में माप की त्रुरटयों या उपकरणों से र्ुड़ी माप की अवनवितताओं को तय सीमाओं के भीतर रखना ह।ै रटप्पण: इस अवधसूचना में, सटीकता श्रेणी के वलए बताई गई मापविज्ञान आिश्यकताओं में गड़बवड़यों के प्रवत अनुमेय प्रवतक्रियाएँ भी शावमल ह।ैं
(29) रटकाऊपन.– उपयोग के दौरान माप यिंत्र की अपनी कायावनष्पादन विशेषताओं को बनाए रखने की क्षमता।
(30) खराबी.– माप यिंत्र की 'त्रुरट सिंकेत' और 'आतिं ररक त्रुरट' के बीच का अिंतर। रटप्पण 1: मुख्य रूप स,े खराबी माप यिंत्र में मौर्ूद या उससे होकर गुर्रने िाल ेडेटा में अनचाह ेबदलाि का नतीर्ा होती ह।ै रटप्पण 2: पररभाषा से यह पता चलता ह ै क्रक "खराबी" एक सिंख्यात्मक मान ह ै वर्से या तो माप की इकाई म ें या सापेक्ष मान के रूप में, र्सै े प्रवतशत के तौर पर, बताया र्ाता ह।ै रटप्पण 3: इस अवधसूचना में, ऊपर दी गई पररभाषा 'अथा फॉल्ट' शब्द पर लागू नहीं होती ह,ै वर्समें 'फॉल्ट' शब्द का अथा िही ह ै र्ो आम तौर पर शब्दकोश में होता ह।ै
(31) महत्िपूणा खराबी.– लागू खराबी सीमा मान स े अवधक खराबी रटप्पण: वनम्नवलवखत को भी महत्िपूणा खराबी माना र्ाता ह:ै • गड़बवड़यों के कारण माप रवर्स्टरों में महत्िपूणा बदलाि मान (3(3)(vi)(ख) देखें) से अवधक बदलाि हुआ ह;ै[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 9 • मीटर की कायाक्षमता खराब हो गई ह।ै
(32) चेककिंग सुविधा.– यह एक ऐसी सुविधा ह ै र्ो माप उपस्करमें शावमल होती ह ै और वर्ससे बड़ी खराबी का पता लगाकर उस पर कारािाई की र्ा सकती ह।ै रटप्पण 1: “कारािाई” से माप उपस्करद्वारा कोई उवचत प्रवतक्रिया (र्सै े रोशनी िाला वसग्नल, आिाज़ िाला वसग्नल, मापने की प्रक्रिया को रोकना, आक्रद अवभप्रेत ह।ै ) रटप्पण 2: इस अवधसूचना के वलए, “माप उपकरण” स े विद्युत का मीटर अवभप्रेत ह।ै बड़ी खराबी का पता चलने पर की र्ाने िाली कारािाई या तो मापना बिंद करना और बिंद होने का समय और अिवध ररकॉडा करना होनी चावहए, या क्रफर खराबी का समय और अिवध तथा खराबी के दौरान मापी गई ऊर्ाा की मात्रा ररकॉडा करनी चावहए। रटप्पण 3: चेककिंग सुविधा के ज़ररए वर्न खरावबयों का पता चलता ह ै और वर्न पर कारािाई की र्ाती है, उन्ह ें बड़ी खराबी नहीं माना र्ाएगा।
(33) प्राइमरी रवर्स्टर.– िह रवर्स्टर वर्स पर इस अवधसूचना की आिश्यकताएिं लागू होती ह।ैं
(34) दो-तरफा (उर्ाा) प्रिाह.– मीटर की िह क्षमता वर्ससे िह दोनों क्रदशाओं (धनात्मक और ऋणात्मक) में उर्ाा प्रिाह को माप सके।
(35) वसफा धनात्मक-क्रदशा में (उर्ाा) प्रिाह – मीटर की िह क्षमता वर्ससे िह वसफा एक क्रदशा (धनात्मक क्रदशा) में उर्ा ा प्रिाह को माप सके।
(36) एक-तरफा (उर्ाा) प्रिाह– मीटर की िह क्षमता वर्ससे िह उर्ाा प्रिाह की क्रदशा की परिाह क्रकए वबना उर्ा ाप्रिाह को माप सके।
(37) धनात्मक (उर्ाा) प्रिाह– उपभोक्ता की ओर उर्ाा प्रिाह की क्रदशा।
(38) ऋणात्मक (उर्ाा) प्रिाह (दो-तरफा और एक-तरफा मीटर के वलए).– धनात्मक क्रदशा के विपरीत उर्ाा प्रिाह की क्रदशा। रटप्पण: वसफा धनात्मक-क्रदशा िाले मामले में, विपरीत क्रदशा को उर्ाा का उल्टा प्रिाह कहा र्ाता ह ै [2(39) देखें]।
(39) उल्टा (उर्ाा) प्रिाह (वसफा धनात्मक-क्रदशा िाले मीटर के वलए) – धनात्मक क्रदशा के विपरीत क्रदशा में प्रिाह।
(40) विवधक रूप से प्रासिंवगक – मापने िाले उपकरण, वडिाइस या सॉफ़्टिेयर के उस वहस्से की विशेषता वर्स पर विवधक वनयिंत्रण लागू होता ह।ै
3. मापविज्ञान आिश्यकताए िं –– (1) माप की इकाइयािं –– सक्रिय विद्यतु उर्ाा के वलए माप की इकाइयािं वनम्नवलवखत में10 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] से कोई एक होंगी: Wh, kWh, MWh, GWh। 3(2) वनधााररत पररचालन वस्थवतयािं –– वनधााररत पररचालन वस्थवतया िं सारणी 1 में बताई गई ह।ैं सारणी 1 वनधााररत पररचालन वस्थवतया िं गुणित्ता को प्रभावित करना या मान, रेंर् उसकी वस्थवत तय करना फ्रीवेंसी f ± 2 % र्हा ँ f की र्ानकारी विवनमााता द्वारा दी र्ानी चावहए। nom nom अगर विवनमााता एक से ज़्यादा नॉवमनल फ़्रीवेंसी बताता है, तो वनधााररत पररचालन वस्थवतयाँ सभी ± 2 % अिंतरालों के सिंयोर्न के रूप में होंगी। िोल्टेर् U ± 10 % र्हा ँ U की र्ानकारी विवनमााता द्वारा दी र्ाएगी। nom nom विवभन्न िोल्टेर् सीमाओं पर सचिं ावलत होन े के वलए वडज़ाइन क्रकए गए मीटरों म ें विवनमााता द्वारा वनर्दाष्ट लाग ू U मान होने चावहए। यक्रद विवनमााता एक स े अवधक nom नॉवमनल िोल्टेर् वनर्दाष्ट करता ह,ै तो वनधााररत पररचालन वस्थवतयाँ सभी U ± nom 10 % अिंतरालों के सिंयोर्न के रूप में होंगी। करिंट I से I st अवधकतम I , I , I और I के बारे में विवनमााता द्वारा वनम्नवलवखत के अनसु ार अवधकतम tr न्यनू तम st र्ानकारी दी र्ानी ह:ै क्रदशा से सटीकता श्रेणी र्ुड़ा क ख ग घ I ≥ 50 ≥ 50 ≥ 50 ≥ 50 अवधकतम /I tr I ≥ 100 ≥ 125 ≥ 250 ≥ 250 अवधकतम /I न्यनू तम I ≥ 1000 ≥ 1250 ≥ 150 ≥ 1250 अवधकतम /I st ट्ािंसफामार सटीकता श्रेणी पररचावलत क ख ग घ I /I ≥ 24 ≥ 24 ≥ 24 ≥4 अवधकतम tr I /I ≥ 60 ≥ 120(1) ≥ 120 ≥ 120 अवधकतम न्यनू तम I /I ≥ 480 ≥ 600 ≥ 1200 ≥ 1200 अवधकतम st रटप्पण (1): ≥60 के वलए श्रेणी ख ट्ािंसफॉमार से चलने िाले इलेक्ट्ोमैकेवनकल मीटर।[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 11 पॉिर फैक्टर 0.5 इिंडवक्टि से 1 से 0.8 कैपेवसरटि तक; वसिाय श्रेणी ग और घ के, र्हाँ पररचालन रेंर् 0.5 इिंडवक्टि से 1 से 0.5 कैपेवसरटि तक होती ह।ै दो-तरफा मीटर के वलए, पािर फैक्टर रेंर् की सीमाएँ दोनों क्रदशाओं में लागू होती ह।ैं तापमान विवनमााता द्वारा बताई गई कम से कम और अवधक से अवधक तापमान की सीमा तक। विवनमााता को इन मानों में से कम से कम तापमान की सीमा बतानी होगी: –55 ºC, –40 ºC, –25 ºC, –10 ºC, +5 ºC। विवनमााता को इन मानों म ेंस ेअवधक से अवधक तापमान की सीमा बतानी होगी: +30 ºC, +40 ºC, +55 ºC, +70 ºC। नमी और पानी नमी के मामले में, विवनमााता को उस पयाािरण श्रेणी के बारे में बताना होगा वर्सके वलए उपस्करबनाया गया ह:ै H1: बिंद र्गह ें र्हाँ उपस्करपर भाप से बना पानी, बाररश या बफा नहीं र्मती, H2: बिंद र्गह ें र्हाँ उपस्करपर भाप से बना पानी, बाररश के अलािा अन्य स्रोतों स े पानी और बफा र्म सकती ह,ै H3: सामान्य मौसम िाली खुली र्गह।ें कनेक्शन के विवनमााता को यह बताना होगा क्रक मीटर का उपयोग सीधे कनेक्शन के वलए क्रकया प्रकार र्ाएगा, या करिंट ट्ािंसफॉमार के ज़ररए, या क्रफर करिंट और िोल्टेर् ट्ािंसफॉमार के ज़ररए। विवनमााता को कनेक्शन का तरीका (या तरीके), मीटर में माप करने िाले एवलमेंट की सिंख्या और उस इलेवक्ट्क वसस्टम के फेज़ की सिंख्या बतानी होगी वर्सके वलए मीटर बनाया गया ह।ै इस अवधसूचना के अनुसार मीटर, नीचे दी गई चीज़ों में से एक या ज़्यादा हो सकता ह ै (लेक्रकन यह इन्हीं तक सीवमत नहीं ह)ै :
वििरण लसिंगल-फेज़ टू-िायर, 1 एवलमेंट लसिंगल-फेर् थ्री-िायर, 1 एवलमेंट (केिल बैलेंस्ड और वसमेरट्कल िोल्टेर् के वलए लागू) लसिंगल-फेज़ थ्री-िायर, 2-एवलमेंट थ्री-फेज़ फोर-िायर, 3-एवलमेंट थ्री-फेज़ थ्री-िायर, 2-एवलमेंट (वसफा उन मामलों में लागू र्हाँ लीकेर् करिंट की सिंभािना न हो) टू-फेज़ थ्री-िायर, 2-एवलमेंट (थ्री-फेज़ सर्िास के दो फेज़ पर काम करने के वलए। यह एक थ्री-फेज़ मीटर भी हो सकता ह ै वर्स े टू-फेज़ थ्री-िायर की तरह चलाया र्ाए) विवनमााता पॉली-फेज़ मीटर के वलए कनेक्शन के िैकवल्पक तरीके बता सकता ह।ै कनेक्शन के ये िकै वल्पक तरीके भी पररचालन शतों का वहस्सा होंगे। रटल्ट माउिंटटिंग की वस्थवत विवनमाता ा द्वारा बताई गई वस्थवत के अनुसार ± 3 वडग्री होनी चावहए। यक्रद माउिंटटिंग की कोई वस्थवत नहीं बताई गई ह,ै तो क्रकसी भी वस्थवत में12 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] माउिंट क्रकया र्ा सकता ह।ै हामोवनक्स िोल्टेर् और करिंट को साइनसोइडल रूप से अलग होन े की अनुमवत होगी, र्ैसा क्रक 3(3)(v), टेबल 4 “िोल्टेर् और करिंट सर्काट में हामोवनक्स” की आिश्यकताओं में बताया गया ह।ै लोड बैलेंस पॉली-फेज़ मीटर और लसिंगल-फेज़ 3-िायर मीटर के वलए, लोड बैलेंस को पूरी तरह से सिंतुवलत वस्थवत स े लेकर केिल एक करिंट सर्काट में करिंट होने की वस्थवत तक बदलने की अनुमवत होगी। रटप्पण: अलग-अलग वनधााररत पररचालन वस्थवतयों के वलए कुछ खास मान बताएिं गए ह ैं (अनुलग्नक ख देखें)।
(3) सटीकता की आिश्यकताएिं.–
(i) सामान्य.– विवनमााता को मीटर की सटीकता श्रेणी को क, ख, ग या घ में से एक के रूप में बताना होगा। रटप्पण: बड़े उपभोक्ताओं, अथाात् र्हाँ खपत 5000 kWh/िषा से ज़्यादा ह,ै उनके वलए श्रेणी ख सबसे कम सटीकता िाली श्रेणी ह ै वर्सकी अनुमवत ह।ै मीटर को इस तरह से वडज़ाइन और बनाया र्ाना चावहए क्रक तय पररचालन वस्थवतयों में, उसकी त्रुरट उस खास श्रेणी के वलए तय अवधकतम अनुमेय सीमा से ज़्यादा न हो। मीटर को इस तरह स े वडज़ाइन और बनाया र्ाना चावहए क्रक बाहरी रुकािटों या गड़बवड़यों के सिंपका म ें आन े पर उसम ें कोई बड़ी खराबी न आए। क्रकसी खराबी को 'बड़ी खराबी' तब नहीं माना र्ाएगा, र्ब उसका क्रकसी चेककिंग सवु िधा के माध्यम से पता लगाया र्ाए और उस पर कारािाई की र्ाए। यक्रद ऐसी कोई घटना होती है, तो मीटर को इसे स्पष्टता दर्शात करना चावहए [2(31) और 2(32)]। रटप्पण : कोई खराबी होने पर सिंकेत के तौर पर लाइट फ्लैलशिंग हो सकती ह।ै
(ii) ऊर्ाा प्रिाह की क्रदशा.– र्हाँ क्रकसी विवनमााता ने विवनर्दाष्ट क्रकया ह ै क्रक मीटर दो-तरफा ऊर्ाा प्रिाह करन े में सक्षम होगा, िहाँ मीटर को धनात्मक और ऋणात्मक दोनों तरह के औसत ऊर्ाा प्रिाह को सही ढिंग से सिंभालना होगा और उस े दोनों क्रदशाओं में ऊर्ाा प्रिाह के वलए इस अवधसूचना की अपेक्षाओं को पूरा करना होगा। ऊर्ाा प्रिाह की ध्रुिता मीटर के वलए विवनमााता के कनेक्शन वनदेशों के अनुसार तय की र्ाएगी। औसत ऊर्ाा प्रिाह का मतलब ह ै सामान्य आिती के कम से कम एक चि में एकीकृत सक्रिय शवक्त को वनर्दाष्ट करती ह।ै मीटर वनव्न्लवखत श्रेवणयों में से कम से कम एक श्रेणी में आएगा:
• एकल -रवर्स्टर, दो-तरफा, र्हाँ मीटर को धनात्मक और ऋणात्मक दोनों तरह के औसत ऊर्ा ा प्रिाह को मापन े में सक्षम बताया गया है, और र्हा ँ कुल पररणाम को एक ही रवर्स्टर में दर्ा क्रकया र्ाएगा; • दो -रवर्स्टर, दो-तरफा, र्हाँ मीटर को धनात्मक और ऋणात्मक दोनों तरह के औसत ऊर्ा ा प्रिाह को मापने में सक्षम बताया गया ह ै (र्ैसा क्रक[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 13 मीटर के कनेक्शन स े तय होता ह)ै , और र्हा ँ धनात्मक और ऋणात्मक पररणाम को अलग-अलग रवर्स्टरों में दर् ा क्रकया र्ाता ह;ै • एकल -रवर्स्टर, केिल धनात्मक क्रदशा, र्हाँ मीटर को केिल धनात्मक औसत ऊर्ाा प्रिाह को मापने और दर्ा करने में सक्षम बताया गया ह।ै हो सकता ह ै क्रक अपनी बनािट के कारण यह स्िाभाविक रूप से केिल धनात्मक औसत ऊर्ाा प्रिाह को दर्ा करे, या क्रफर इसमें ररिस ा रलनिंग वडटेंट लगा हो;
• एकल -रवर्स्टर, एक-तरफा, र्हाँ मीटर को औसत ऊर्ाा प्रिाह के एब्सोल्यूट मान को मापने और दर्ा करने में सक्षम बताया गया है, िहाँ आम तौर पर ऐसा मीटर ऊर्ाा प्रिाह की िास्तविक क्रदशा या मीटर के कनेक्शन के तरीके की परिाह क्रकए वबना, सारी ऊर्ाा को 'खपत हुई ऊर्ाा' के तौर पर दर्ा करेगा। दो-तरफा मीटर के मामले में, र्ब प्रिाह की क्रदशा बदलेगी, तो ऊर्ाा सही रवर्स्टर में दर्ा होगी। रटप्पण 1: ऊपर दी गई सूची में " एकल -रवर्स्टर" और " दो -रवर्स्टर" शब्द वसफा बेवसक एनर्ी रवर्स्टर (या रवर्स्टरों) के वलए उपयोग क्रकए गए ह।ैं मीटर में दसू रे रवर्स्टर भी हो सकते हैं, र्सै े टैररफ और/या फेज़ की र्ानकारी भिंडारण करने के वलए। रटप्पण 2: अगर आिश्यक हो, तो वनदेशक (विवधक मापविज्ञान), केन्रीय विद्यतु प्रावधकरण या सरकार द्वारा अवधकृत क्रकसी अन्य सिंस्था स े परामशा करके यह तय कर सकते ह ैं क्रक कौन से मीटर के प्रकार और गणना के तरीके सही ह।ैं
(iii) आधार अवधकतम अनुमये त्रुरटयाँ.– र्ब करिंट और पािर फैक्टर को सारणी 2 में दी गई सीमाओं (पररचालन रेंर्) के भीतर बदला र्ाता ह,ै और र्ब मीटर को सन्दभा वस्थवतयों में चलाया र्ाता ह,ै तो िास्तविक त्रुरट (प्रवतशत में बताई गई) सारणी 2 में बताई गई आधार अवधकतम अनुमेय त्रुरट के भीतर होगी। सारणी 2 आधार अवधकतम अनुमेय त्रुरट और शून्य लोड अपेक्षाएिं मात्रा मीटर श्रेणी के वलए आधार अवधकतम अनुमेय त्रुरट (%) करिंट I पॉिर फैक्टर क ख ग घ I ≤I ≤I यूवनटी ± 2.0 ± 1.0 ± 0.5 ± 0.2 tr max
0.5 इिंडवक्टि से 1 से 0.8 ± 2.5 ± 1.5 ± 0.6 ± 0.3 कैपेवसरटि(1) I ≤I < I Unity ± 2.5 ± 1.5 ± 1.0 ± 0.4 min tr
0.5 इिंडवक्टि से 1 से 0.8 ± 2.5 ± 1.8 ± 1.0 ± 0.5 कैपेवसरटि I ≤I < I यूवनटी ± 2.5·I /I ± 1.5·I /I ± 1.0·I /I ± 0.4·I /I st min min min min min
(1) पािर फैक्टर की आिश्यक्ता 0.5 इिंडवक्टि से 1 और क्रफर 0.5 कैपेवसरटि तक होती ह।ै14 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] रटप्पण: प्रकार मूल्यािंकन से वमलने िाली सिंयुक्त अवधकतम अनुमेय त्रुरट (सीएमपीई) और सिंयुक्त अवधकतम त्रुरट (सीएमई) की गणना अनुलग्नक क (1) और अनुलग्नक क (2) में बताए गए तरीके से की र्ा सकेगी ।
(iv) शून्य लोड.– शून्य लोड की वस्थवत में कोई भी महत्िपणू ा ऊर्ाा दर्ा नहीं होगी। (परीक्षण प्रक्रिया के वलए खिंड 6(2)(iv) देखें)। रटप्पण: I से कम करिंट के वलए मीटर को हमेशा रुकने क्रदया र्ाता ह।ै st
(v) प्रभाि मात्रा के स्िीकाया प्रभाि – र्ब मीटर को सिंदभ ा वस्थवतयों में चलाया र्ाए, तो मीटर का तापमान गुणािंक सारणी 3 की अपेक्षाओं को परू ा करना होगा। सारणी 3 त्रुरट के तापमान गणु ािंक की सीमाए ँ प्रभाि मात्रा पॉिर फैक्टर श्रेणी के मीटरों के तापमान गुणािंक /%)K) की सीमाए ँ क ख ग घ (1) तापमान रेंर् के भीतर क्रकसी भी 1 ± 0.1 ± 0.05 ± 0.03 ± 0.01 अिंतराल पर, करिंट I ≤I ≤I के वलए, tr max 0.5 ± 0.15 ± 0.07 ± 0.05 ± 0.02 तापमान गुणािंक (%/K), र्ो 15K स े इिंडवक्टि कम और 23K स े अवधक न हो।
(1) ये मान –10 °सेंटीग्रेड से नीचे दोगुने हो र्ाते ह।ैं र्ब मीटर को सिंदभा वस्थवतयों में चलाया र्ा रहा हो और लोड करिंट और पािर फैक्टर को वनधााररत पररचालन रेंर् के भीतर क्रकसी एक लबिंद ुपर वस्थर रखा र्ाए, और र्ब क्रकसी एक प्रभाि मात्रा को सिंदभा वस्थवतयों िाले मान से बदलकर सारणी 4 में बताई गई अवधकतम मान तक ले र्ाया र्ाए, तो त्रुरट में बदलाि ऐसा होगा। क्रक अवतररक्त प्रवतशत त्रुरट, सारणी 4 में बताए गए त्रुरट बदलाि की सिंबिंवधत सीमा के भीतर हो। इन सभी परीक्षण के पूरा होने के पिात भी मीटर काम करता होगा। सारणी 4 प्रभाि मात्रा के कारण त्रुरट-सीमा में बदलाि प्रभाि मात्रा मान पररक्षण खिंड करिंट का पॉिर श्रेणी के मीटरों के वलए त्रुरट बदलाि की (%) सीमा मान फैक्टर क ख ग घ सेल्फ-हीटटिंग I अवधकतम पर 6(2)(ii) I अवधकतम 1; 0.5 ± 1 ± 0.5 ± 0.25 ± 0.1 लगातार करिंट इिंडवक्टि लोड बैलेंस(1) वसफा एक ही करिंट 6(3)(iii) Itr ≤I ≤ I 1 ± 1.5(2) ± 1.0 ± 0.7 ± 0.3 सर्काट में करिंट अवधकतम 0.5 ± 2.5(2) ± 1.5 ± 1 ± 0.5 इिंडवक्टि[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 15 िोल्टेर् में Unom ±10 % 6(3)(iv) Itr ≤I ≤ I 1 ± 1.0(9) ± 0.7 ± 0.2 ± 0.1 उतार-चढाि अवधकतम 0.5 ± 1.5 ± 1.0 ± 0.4 ± 0.2
(3) इिंडवक्टि फ्रीवेंसी में fnom ±2 % 6(3)(v) Itr ≤I ≤ I 1 ± 0.8 ± 0.5 ± 0.2 ± 0.1 उतार-चढाि अवधकतम 0.5 ± 1.0 ± 0.7 ± 0.2 ± 0.1 इिंडवक्टि िोल्टेर् और d is 0 – 40 % 6(3)(vi) Itr ≤I ≤ I 1 ± 1.0(5) ± 0.6 ± 0.3 ± 0.2 करिंट सर्काट में I, 0 – 5 % U (4) अवधकतम हामोवनक्स रटल्ट ≤ 3 वडग्री 6(3)(vii) Itr ≤I ≤ I 1 ± 1.5 ± 0.5 ± 0.4 n/a अवधकतम सिार िोल्टेर् 0.8 Unom ≤U < 6(3)(viii) 10 Itr 1 ± 1.0(15) ± 1 ± 0.6 ± 0.3 उतार-चढाि
0.9 Unom; 1.1 Unom < U ≤1.15 Unom U < 0.8 Unom +10 to –100 एक या दो फेज़ एक या दो फेज़ 6(3)(ix) 10 Itr 1 ± 4 ± 2 ± 1 ± 0.5 में रुकािट हटा क्रदया गया आई। (6) एसी करिंट समान पािर 6(3)(x) 10 Itr 1 ± 3 ± 1.5 ± 0.75 ± 0.5 सर्काट में सब- िाला करिंट वसग्नल हामोवनक्स वर्समें सब- हामोवनक्स मौर्ूद हैं। एसी करिंट 90 वडग्री पर फेज़- 6(3)(xi) 10 Itr 1 ± 1 ± 0.8 ± 0.5 ± 0.4 सर्काट में फायडा हामोवनक्स ररिस्डा फेज़ क्रकन्हीं दो फेज़ को 6(3)(xii) 10 Itr 1 ± 1.5 ± 1.5 ± 0.1 ± वसवेंस आपस में बदला
0.05 गया बाहरी स्रोत से कोर की सतह से 6(3)(xiii) 10 Itr 1 ± 3 ± 1.5 ± 0.75 ± 0.5 लगातार 30 एमएम की (डीसी) दरू ी पर 200 mT चुिंबकीय प्रेरण
(10)
(10) बाहरी स्रोत 400 A/m 6(3)(xiv) 10 Itr, 1 ± 2.5 ± 1.3 ± 0.5 ± का चुिंबकीय Iअवधकतम 0.25 क्षेत्र (एसी, पािर फ़्रीवेंसी)। रेवडएटेड, f = 80 to 6000 6(3)(xv)(a) 10 Itr 1 ± 3 ± 2 ± 1 ± 1 आरएफ, MHz, फील्ड स्ट्ेंथ इलेक्ट्ोमैग्नेरटक ≤10 V/m फील््स रेवडयो फ़्रीवेंसी f = 0.15 to 80 6(3)(xv)(b) 10 Itr 1 ± 3 ± 2 ± 1 ± 1 फील्ड से उत्पन्न MHz, किंडक्टेड ए्प्लीट्युड ≤10 वडस्टबेंस (7) V एसी करिंट साइनसोइडल 6(3)(xvi) Iअवधकतम/√ 1 ± 6 ± 3 ± 1.5 ± 1 सर्काट में डीसी करिंट, दोगुना 2
(8) आयाम, हाफ-िेि रेवक्टफाइड; I ≤Imax/√216 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] हाई-ऑडार सुवप्रमपोस्ड: 6(3)(xvii) Itr 1 ± 1 ± 1 ± 0.5 ± 0.5 हामोवनक्स 0.02 Unom; 0.1 Itr; 15 fnom to 40 fnom
(1) वसफा पॉली-फेज़ और लसिंगल-फेज़ 3-िायर मीटर के वलए।
(2) अगर त्रुरट ±2.5% के अिंदर ह,ै तो त्रुरट बदलाि दी गई सारणी में बताएिं गई मान से ज़्यादा हो सकती ह।ै
(3) पॉली-फेज़ मीटर के वलए वसमेरट्कल िोल्टेर् उतार-चढाि की आिश्यक्ता होती ह।ै
(4) र्ब तक आर.एम.एस. करिंट Iअवधकतम से ज़्यादा न हो और करिंट का वशखर मान 1.41·I max से ज़्यादा न हो। इसके अवतररक्त, अलग- अलग हामोवनक किंपोनेंट्स का ए्प्लीट्यूड करिंट के वलए (I1 / h) और िोल्टेर् के वलए (0.12 · U / h) से ज़्यादा नहीं होगा र्हाँ h 1 हामोवनक ऑडार है।
(5) इलेक्ट्ोमैकेवनकल मीटर के मामले में, अगर त्रुरट ± 3.0% के अिंदर ह,ै तो त्रुरट बदलाि तावलका में बताएिं गए मान से ज़्यादा हो सकेगा ।
(6) यह मात्र पॉली-फेज़ मीटर के वलए है। दो फेज़ का कट र्ाना वसफा उन कनेक्शन मोड के वलए ह ैर्हाँ एक फेज़ के न होने पर भी उर्ाा पहुचिं ाई र्ा सकेगी । यह अपेक्षा मात्र नेटिका की खराबी की वस्थवतयों पर लागू होती है, न क्रक क्रकसी दसू रे कनेक्शन मोड पर। यक्रद कोई पॉली-फेज़ मीटर अपने क्रकसी एक फेज़ से चल रहा है, तो इस परीक्षण के वलए उस फेज़ का िोल्टेर् नहीं काटा र्ाएगा।
(7) रेवडयो-फ़्रीवेंसी फील्ड से उत्पन्न होने िाली प्रत्यक्ष या अप्रत्यक्ष किंडक्टेड वडस्टबेंस।
(8) वसफा प्रत्यक्ष र्ुड़े मीटरों के वलए।
(9) श्रेणी क के इलेक्ट्ोमैकेवनकल मीटर के वलए, 10 I tr से कम मात्रा पर यह अपेक्षा लागू नहीं होती ह।ै
(10) इसके अवतररक्त, विवनमााता 200 mT से ज़्यादा के लगातार (डीसी) मैग्नेरटक इिंडक्शन का पता चलने पर अलामा की सुविधा भी दे सकते ह।ैं
(11) इलेक्ट्ोमैकेवनकल मीटर के वलए, यह मान दोगुना हो र्ाता ह।ै
(vi) गड़बवड़यों के स्िीकाया प्रभाि,– (क) साधारण.– मीटर को सामान्य उपयोग के दौरान होने िाली गड़बवड़यों को सहन करने में सक्षम होगा; र्ैसा क्रक
3.3.1 में बताया गया ह,ै सारणी 5 में दी गई क्रकसी भी गड़बड़ी के कारण कोई बड़ी खराबी नहीं होगी। (ख) गड़बवड़याँ.– सारणी 5 में बताए गए स्तर से ज़्यादा का त्रुरट बदलाि एक बड़ी खराबी माना र्ाता ह।ै यक्रद क्रकसी मीटर को सारणी 5 में बताई गई वस्थवतयों में चलाया र्ाता ह ैऔर उसमें कोई करिंट नहीं क्रदया र्ाता है, तो परीक्षण आउटपुट के रवर्स्टर या पल्स में होने िाले बदलाि को बड़ी खराबी नहीं माना र्ाएगा, परन्त ु रवर्स्टर में बदलाि या टेस्ट आउटपुट की बराबर ऊर्ाा kWh में m ⋅U ⋅I ⋅10 −6 (क्रिरटकल चेंर् िैल्यू) से कम हो; यहा ँm मापन े nom max िाले एवलमेंट की सिंख्या ह,ै U िोल्ट में ह ै और I ए्पीयर में ह।ै nom max सारणी 5 गड़बवड़याँ गड़बड़ी की मात्रा परीक्षण खिंड गड़बड़ी का स्तर स्िीकृत प्रभाि श्रेणी के मीटरों के वलए त्रुरट बदलाि की (%) सीमा क ख ग घ बाहरी स्रोत का 6(4)(ii) 1000 A/m, कोई खास - - - - चुिंबकीय क्षेत्र (एसी, खराबी नहीं 3 s पािर फ़्रीवेंसी)।[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 17 इलेक्ट्ोस्टैरटक 6(4)(iii) 8 kV कॉन्टैक्ट कोई खास - - - - वडस्चार्ा खराबी नहीं वडस्चार्ा; 15 kV एयर वडस्चार्ा। फास्ट ट्ािंवर्एिंट्स 6(4)(iv) िोल्टेर् और 6.0 4.0 2.0 1.0 करिंट सर्काट: 4 kV; सहायक सर्काट: 2 kV.
िोल्टेर् वडप्स 6(4)(v) परीक्षण क: 30 कोई खास - - - - खराबी नहीं %, 0.5 चि परीक्षण ख: 60 %, 1 चि परीक्षण ग: 60 %, 25/30 चि
(3) िोल्टेर् में रुकािटें 6(4)(v) 0 %, - - - - 250/300 चि
(3) रेवडएटेड, आरएफ, 6(4)(vi) f = 80 to कोई खास - - - - खराबी नहीं इलेक्ट्ोमैग्नेरटक 6000 MHz, फील्ड 30 V/m, ए्प्लीट्यूड मॉड्यूलेटेड, वबना करिंट के। एसी मुख्य विद्युत 6(4)(vii) िोल्टेर् सर्काट: कोई खास - - - - लाइनों पर सर् ा खराबी नहीं 2 kV लाइन से लाइन, 4 kV लाइन से अथा;
सहयक सर्काट:
1 kV लाइन से लाइन, 2 kV लाइन से अथा। डै्प्ड ऑवसलेटरी 6(4)(viii) िोल्टेर् सर्काट: कोई खास 3.0 2.0 2.0 1.0 िेव्स इ्युवनटी टेस्ट खराबी नहीं। कॉमन मोड 2.5
(1) मीटर के kV, कामकार् में वडफरेंवशयल कोई बाधा नहीं आनी18 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] मोड 1.0 kV. चावहए। अल्पकावलक 6(4)(ix) प्रत्यक्ष रुप से कोई खास ट्ािंसफमार –पररचावलत ओिरकरिंट र्ुड़े मीटर: खराबी नहीं।
1.0 0.5 0.05 0.05 कोई नुकसान 30· Iअवधकतम; प्रत्यक्ष रुप से र्ुड़े मीटर नहीं होगा। ट्ािंसफमार – 1.5 1.5 0.05 0.05 पररचावलत मीटर:
20·I . अवधकतम आिेग िोल्टेर् 6(4)(x) 3 kV (≤100 कोई खास - - - - खराबी नहीं। V); कोई नुकसान 6 kV (≤150 नहीं होगा। V) ;
10 kV (≤300 V) ;
12 kV (≤600 V). अथा फॉल्ट(2) 6(4)(xi) एक फेज़ में अथा कोई खास 1.0 0.7 0.3 0.1 फॉल्ट खराबी नहीं। कोई नुकसान नहीं होगा और ठीक से काम करेगा। सहायक उपकरणों 6(4)(xii) सहायक कोई खास 1/3 बेस एमपीई ½ बेस का सिंचालन उपस्करI = खराबी नहीं। एमपीई I and न्यूनतम I से अवधकतम सिंचावलत होत े ह ैं किंपन 6(4)(xiii)(a) एक-दसू रे के कोई खास 1/3 बेस एमपीई ½ बेस लिंबित तीन खराबी नहीं। एमपीई अक्षों में किंपन मीटर के कामकार् में कोई बाधा नहीं आनी चावहए। शॉक 6(4)(xiii)(b) पल्स का आकार: कोई खास 1/3 बेस एमपीई ½ बेस हाफ-साइन, पीक खराबी नहीं। एमपीई एक्सेलरेशन:
300 ms-2, पल्स की अिवध: 18 एमएस[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 19 सौर विक्रकरण से 6(4)(xiv) साइक्रकललिंग ररग क्रदखािट में - - - - सुरक्षा के साथ 66 कोई बदलाि नहीं और न क्रदनों तक 340 ही nm पर 0.76 कायाक्षमता, W·m2·nm-1, मापविज्ञान गुणों और सीललिंग में कोई कमी। धूल के प्रिेश से 6(4)(xv) IP 5x, कैटेगरी सही कामकार् - - - - सुरक्षा में कोई 2 एनक्लोज़र रुकािट या सुरक्षा से कोई समझौता नहीं, वर्समें िीपेर् दरू ी के साथ ट्ैककिंग भी सव्मवलत ह।ै सूखी गमी 6(4)(xvi)(a) अवधकतम कोई खास 1/3 बेस एमपीई ½ बेस वनर्दाष्ट तापमान खराबी नहीं एमपीई सीमा से एक मानक तापमान ऊपर,2 एच ठिंड 6(4)(xvi)(b) न्यूनतम वनर्दाष्ट कोई खास 1/3 बेस एमपीई ½ बेस तापमान सीमा खराबी नहीं एमपीई से एक मानक तापमान नीच,े 2 एच उमस 6(4)(xvi)(c), H1: 30 °C, कोई खास ±0.2 ±0.1 ±0.05 ±0.05 खराबी नहीं। 6(4)(xvi)(d) 85 %; H2:
क्रकसी भी तरह चिीय 25 °C, के मैकेवनकल 95 % से 40 नुकसान या र्िंग का कोई °C, 93 %; साक्ष्य नहीं ह।ै H3: चिीय 25 °C, 95 % से 55 °C, 93 %. पानी 6(4)(xvi)(e) केिल H3, 0.07 कोई खास - - - - खराबी नहीं। L/min (प्रवत क्रकसी भी तरह नोज़ल), 0 ° और के मैकेवनकल 180 °, 10 min नुकसान या20 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] र्िंग का कोई साक्ष्य नहीं ह।ै रटकाऊपन 6(4)(xvii) लिंबे समय तक कोई खास 1/3 बेस एमपीई ½ बेस ज़्यादा करिंट खराबी नहीं। एमपीई और/या तापमान
(1) केिल ट्ािंसफॉमार स े चलने िाले मीटरों के वलए।
(2) केिल उन थ्री-फेज़ फोर-िायर ट्ािंसफॉमार-ऑपरेटेड मीटरों के वलए वर्नका इस्तेमाल अथा फॉल्ट न्यूट्लाइज़र िाले नेटिका में क्रकया र्ाना ह।ै
(3) ये मान िमशः 50 Hz / 60 Hz के वलए ह।ैं यक्रद इस अवधसूचना के भाग 2 में बताए गए आिश्यक परीक्षण के दौरान कोई बड़ी खराबी नहीं आती है, तो यह माना र्ाएगा क्रक मीटर इस उप-खिंड की अपेक्षाओं को पूरा करता ह।ै
(4) इिंटरिल और मल्टी-टैररफ मीटर के वलए अपेक्षाओं.– इिंटरिल मीटर वबललिंग के वलए आिश्यक डेटा को मापने और स्टोर करने में सक्षम होंगे। इस डेटा के वलए कम स े कम स्टोरेर् की अिवध केंरीय विद्युत प्रावधकरण या सरकार द्वारा अवधकृत क्रकसी अन्य सिंस्था द्वारा तय की र्ाएगी। इिंटरिल मीटर के वलए, इिंटरिल डेटा का कुल योग उसी अिवध के दौरान एकत्र हुए रवर्स्टर िैल्यू के बराबर होगा। मल्टी-टैररफ मीटर के वलए, क्रकसी भी समय केिल एक ही रवर्स्टर (कुल योग िाले रवर्स्टर के अवतररक्त) चालू रहना चावहए। हर मल्टी-टैररफ रवर्स्टर में दर्ा मान का कुल योग, कुल योग िाले रवर्स्टर में दर्ा मान के बराबर होगा।
(5) मीटर मार्किंग.– हर मीटर पर वनम्न र्ानकारी वलखी होगी: • विवनमााता • U nom • I max • I tr I • min • मिंज़ूरी का वनशान (माक्सा) • िम सिंख्या • फेज़ की सिंख्या • तारों की सिंख्या • रवर्स्टर मल्टीप्लायर (यक्रद यह 1 के अवतररक्त कुछ और हो) • मीटर कॉन्स्टेंट • विवनमााण का िष ा • एक्यूरेसी क्लास • ऊर्ाा बहाि की क्रदशा (यक्रद मीटर दो-तरफा या एक-तरफा हो)। यक्रद मीटर वसफा धनात्मक क्रदशा में उर्ाा प्रिाह के वलए बना ह,ै तो कोई वनशान लगाने की आिश्यक्ता नहीं ह।ै[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 21 • मीटर का प्रकार • तापमान की रेंर् • नमी और पानी से सरु क्षा की र्ानकारी • इ्पल्स िोल्टेर् से सरु क्षा की र्ानकारी • fnom • िह कनेक्शन मोड वर्सके वलए मीटर बना ह ै • कनेक्शन टर्मानलों के बीच अतिं र करने के वलए उनकी खास पहचान। मार्किंग ऐसी होगी र्ो वमटे नहीं, साफ क्रदखे और मीटर के बाहर स े आसानी से पढी र्ा सके। बाहर लगाई र्ान े िाली र्गहों के वलए बने मीटरों की मार्किंग पर सौर विक्रकरण का असर नहीं पड़ना चावहए। यक्रद बनाने िाली किंपनी ने बताया हो, तो U और f की कई मान को भी माका की र्ा सकती ह।ैं nom nom यक्रद िम सिंख्या अलग क्रकए र्ा सकने िाले वहस्सों पर लगा ह,ै तो िम सिंख्या ऐसी र्गह पर भी होना चावहए र्हाँ से उस े उन वहस्सों से आसानी से अलग न क्रकया र्ा सके र्ो मीटर की मापविज्ञान विशेषताओं को तय करते ह।ैं र्हाँ आिश्यक हो, िहाँ लसिंबल या उनके र्ैसे दसू रे वनशानों का उपयोग क्रकया र्ा सकेगा।
(6) मापविज्ञान गुणों की सुरक्षा.–
(i) साधारण (क) विद्यतु के मीटरों में उनकी मापविज्ञान गुणों की सुरक्षा के वलए साधन होंगे। केिल अवधकृत व्यवक्तयों को ही सॉफ़्टिेयर सुरक्षा (iii), पैरामीटर सुरक्षा (iv) और इिेंट ररकॉडा (ix) की र्ाँच करने की सुविधा तक पहुचँ ने की अनुमवत होगी। (ख) बाहरी र्गहों पर प्रयोग होन े िाले विद्यतु के मीटर की मापविज्ञान गुणों की सुरक्षा के वलए उपयोग क्रकए र्ाने िाल े सभी साधन सौर विक्रकरण को सहन करने में सक्षम होंगे।
(ii) सॉफ़्टिेयर की पहचान.–विद्युत के मीटर के विवधक रूप से महत्िपूणा सॉफ़्टिेयर की पहचान स्पष्ट रूप से सॉफ़्टिेयर िर्ान या क्रकसी अन्य टोकन से की र्ानी चावहए। पहचान में एक से अवधक वहस्से हो सकेंगे, क्रकन्तु कम से कम एक भाग विवधक उद्देश्य के वलए होगा । यह पहचान सॉफ़्टिेयर से अटूट रूप से र्ुड़ी होगी और कमािंड देने पर या ऑपरेशन के दौरान क्रदखाई र्ाएगी। अपिाद के तौर पर, यक्रद नीचे दी गई तीन शतें पूरी होती ह,ैं तो विद्यतु मीटर पर सॉफ्टिेयर की पहचान का वनशान होना एक स्िीकाया समाधान होगा:
(क) यूज़र इिंटरफेस में वडस्प्ले पर सॉफ्टिेयर की पहचान क्रदखाने के वलए कोई वनयिंत्रण क्षमता नहीं है, या वडस्प्ले तकनीकी रूप से सॉफ्टिेयर की पहचान क्रदखाने की सुविधा नहीं दते ा ह ै (र्ैसे एनालॉग इिंवडकेटटिंग वडिाइस या इलेक्ट्ोमैकेवनकल22 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] काउिंटर)। (ख) विद्युत मीटर में सॉफ्टिये र की पहचान बताने के वलए कोई इिंटरफेस नहीं ह।ै (ग) विद्युत मीटर बनने के बाद सॉफ्टिेयर में बदलाि करना सिंभि नहीं है, या यह तभी सिंभि ह ैर्ब हाडािेयर या हाडािेयर का कोई वहस्सा भी बदला र्ाए। हाडािेयर या सिंबिंवधत हाडािये र घटक बनाने िाली किंपनी यह सुवनवित करने के वलए वज़्मेदार ह ै क्रक सिंबिंवधत मीटर पर सॉफ्टिेयर की पहचान सही ढिंग से अिंक्रकत हो। सॉफ्टिेयर की पहचान और पहचान के तरीके का उल्लेख टाइप अनुमोदन प्रमाण-पत्र में क्रकया र्ाएगा।
(iii) सॉफ्टिेयर सुरक्षा,– (क) गलत इस्तेमाल से बचाि.– विद्युत मीटर को इस तरह से बनाया र्ाएगा क्रक अनर्ाने में, गलती से या र्ानबूझकर गलत इस्तेमाल की सिंभािना कम से कम हो। (ख) धोखाधड़ी से सुरक्षा (खक) विवधक रूप से आिश्यक सॉफ़्टिेयर को वबना अप्रावधकृत उपािंतरण , लोलडिंग या मेमोरी वडिाइस बदलकर क्रकए र्ाने िाल े बदलािों स े सरु वक्षत रखा र्ाएगा वर्न विद्यतु मीटर में सॉफ़्टिेयर/पैरामीटर लोड करन े का विकल्प होता है, उन्ह ें सुरवक्षत रखने के वलए मैकेवनकल या इलेक्ट्ॉवनक सीललिंग र्ैसे सरु वक्षत तरीकों की आिश्यक्ता होती ह।ै (खख) यूज़र इिंटरफेस के माध्यम से केिल साफ तौर पर बताए गए कृत्य (4.1 देखें) ही चालू क्रकए र्ा सकते हैं; इसे इस तरह से बनाया र्ाना चावहए क्रक इससे धोखाधड़ी िाला उपयोग आसान न हो। (खग) सॉफ़्टिेयर सुरक्षा में मैकेवनकल, इलेक्ट्ॉवनक और/या क्रिप्टोग्राक्रफक रीती से सही सीललिंग शावमल है, वर्ससे वबना अप्रावधकृत छेड़छाड़ करना असिंभि हो या साफ तौर पर पता चल र्ाए। उदाहरण:
1) मापने िाले उपस्करका सॉफ़्टिेयर इस तरह बनाया गया ह ै क्रक पैरामीटर और विवधक रूप स े सुसिंगत कॉवन्फगरेशन में बदलाि केिल एक वस्िच-प्रोटेक्टेड मेनू के ज़ररए ही क्रकया र्ा सकता ह।ै यह वस्िच इनएवक्टि पोवज़शन में मैकेवनकली सील होता ह,ै वर्ससे पैरामीटर और विवधक रूप से ज़रूरी कॉवन्फगरेशन में बदलाि करना नामुमक्रकन हो र्ाता ह।ै पैरामीटर और कॉवन्फगरेशन में बदलाि करने के वलए, वस्िच को बदलना पड़ता ह,ै वर्ससे सील टूट र्ाती ह।ै
2) मापने िाले उपस्करका सॉफ़्टिेयर इस तरह बनाया गया ह ै क्रक पैरामीटर और विवधक रूप से सुसिंगत कॉवन्फगरेशन तक केिल अवधकृत व्यवक्त ही पहुचँ सकत े ह।ैं अगर कोई व्यवक्त पैरामीटर मेनू आइटम में र्ाना चाहता ह,ै तो उसे अपना स्माटा काडा लगाना होगा वर्समें क्रिप्टोग्राक्रफक प्रमाणपत्र के वहस्से के तौर पर पी आई एन हो। उपस्कर का सॉफ़्टिेयर प्रमाणपत्र के माध्यम से पी आई एन की प्रमावणकता की र्ाँच कर सकता ह ै और पैरामीटर मेनू आइटम में प्रिेश की[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 23 अनुमवत देता ह।ै इस पहुचिं को ऑवडट ट्ेल में ररकॉडा क्रकया र्ाता है, वर्समें उस व्यवक्त (या कम से कम प्रयोग क्रकए गए स्माटा काडा) की पहचान शावमल होती ह।ै
(iv) पैरामीटर सुरक्षा,– (क) विद्युत मीटर की विवधक रूप स े आिश्यक विशेषताओं को तय करने िाल े पैरामीटर को वबना अनुमवत के बदलाि स े सुरवक्षत रखा र्ाना चावहए। यक्रद र्ािंच के वलए आिश्यक हो, तो विद्यमान पैरामीटर सेटटिंग्स को देखा र्ा सकना चावहए। वडिाइस-विवशष्ट पैरामीटर को केिल विद्यतु मीटर के विवशष्ट प्रचलन मोड में ही बदला या चुना र्ा सकता ह।ै इन्ह ें दो तरह से बािंटा र्ा सकता ह:ै वर्न्ह ें सुरवक्षत (बदलाि न हो सकन े िाला) रखा र्ाना चावहए और वर्न्ह ें क्रकसी अवधकृत व्यवक्त र्ैसे उपकरण का मावलक या मर्मत करने िाले के पहुचिं (सेट पैरामीटर) बनाया र्ा सकता ह।ै एक ही तरह के सभी वडिाइस के वलए 'टाइप-विवशष्ट' परै ामीटर के मान एक र्सै े होते ह।ै ये उपस्करके टाइप अनमु ोदन के समय तय क्रकए र्ाते ह।ैं रटप्पण 1: पैरामीटर को सुरवक्षत रखने के वलए केिल एक साधारण पासिडा तकनीकी रूप से सही समाधान नहीं ह।ै रटप्पण 2: अवधकृत व्यवक्तयों को वडिाइस-विवशष्ट पैरामीटर के सीवमत सेट को एक्ससे करने की अनुमवत दी र्ा सकती ह।ै ऐस े वडिाइस-विवशष्ट पैरामीटर के सेट और उनके एक्सेस की सीमाओं/वनयमों को स्पष्ट रूप से प्रलेवखत क्रकया र्ाना चावहए। (ख) कुल मापी गई ऊर्ाा को स्टोर करने िाले रवर्स्टर को शून्य करना, वडिाइस-विवशष्ट पैरामीटर में बदलाि माना र्ाएगा। इसवलए, वडिाइस-विवशष्ट पैरामीटर पर लागू होने िाली सभी आिश्यक शतें शून्य करने की प्रक्रिया पर भी लागू होंगी। (ग) वडिाइस-विवशष्ट पैरामीटर में बदलाि करते समय, मीटर ऊर्ाा को ररकॉडा करना बिंद कर देगा। (घ) कुछ वडिाइस-विवशष्ट पैरामीटर उपयोगकता ा के वलए उपलब्ध होंगे। तथावप, मापने िाले उपस्करम ें वडिाइस-विवशष्ट पैरामीटर में क्रकए गए क्रकसी भी बदलाि को अपने-आप और वबना वमटाए ररकॉडा करने की सुविधा होनी चावहए, र्ैसे क्रक ऑवडट ट्ेल। उपस्करररकॉडा क्रकए गए डेटा को क्रदखाने में सक्षम होना चावहए। पता लगाने की क्षमता के साधन और ररकॉडा विवधक रूप से ज़रूरी सॉफ़्टिेयर का वहस्सा ह ैं और उन्ह ें उसी तरह सरु वक्षत रखा र्ाना चावहए। ऑवडट ट्ेल क्रदखाने के वलए प्रयोग क्रकया र्ान ेिाला सॉफ़्टिेयर, विवधक रूप स ेतय ज़रूरी सॉफ़्टिेयर का वहस्सा होता ह।ै रटप्पण: इिेंट काउिंटर तकनीकी रूप से स्िीकाय ा समाधान नहीं ह।ै
(v) इलेक्ट्ॉवनक वडिाइस और सब-असेंबली को अलग रखना – विवधक मापविज्ञान रूप से विद्युत मीटर के महत्िपूणा वहस्सों – चाह े िे सॉफ्टिेयर हों या हाडािेयर – पर मीटर के दसू रे वहस्सों का अनुवचत प्रभाि नहीं पड़ना चावहए।24 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (क) विद्युत मीटर के उन सब-असेंबली या इलेक्ट्ॉवनक वडिाइस की पहचान की र्ानी चावहए, उन्ह ें साफ तौर पर पररभावषत क्रकया र्ाना चावहए और उनका प्रलेवखत क्रकया र्ाना चावहए, र्ो विवधक रूप से ज़रूरी काम करत े ह।ैं ि े मापने िाले वसस्टम का विवधक रूप से ज़रूरी वहस्सा होते हैं। अगर विवधक रूप स े ज़रूरी काम करन े िाले सब-असेंबली की पहचान नहीं की र्ाती ह,ै तो सभी सब-असेंबली को विवधक रूप से ज़रूरी काम करने िाला माना र्ाएगा। उदाहरण:
1) विद्युत मीटर में माप का मान पढने के वलए इलेक्ट्ॉवनक वडिाइस को र्ोड़न े के वलए एक ऑवप्टकल इिंटरफेस होता ह।ै मीटर सभी ज़रूरी मात्राओं को स्टोर करता ह ैऔर मान को काफी समय तक पढने के वलए उपलब्ध रखता ह।ै इस वसस्टम में वसफा विद्युत मीटर ही विवधक रूप से ज़रूरी वडिाइस ह।ै दसू रे वडिाइस र्ो विवधक रूप से ज़रूरी नहीं हैं, िे भी हो सकत े ह ैं और उपस्करके इिंटरफेस स े र्ुड़ े हो सकत े ह,ैं परन्तु आिश्यक 3(6)(फ)(ख) पूरी हो। डेटा ट्ासिं वमशन को सरु वक्षत करने की अपेक्षा नहीं ह ै [3(6)(vii) देखें]। (ख) टाइप परीक्षण के दौरान, यह क्रदखाया र्ाना चावहए क्रक सब-असेंबली और इलेक्ट्ॉवनक वडिाइस के आिश्यक कामों और डेटा पर इिंटरफेस के ज़ररए वमले कमािंड का कोई गलत असर न पड़े। इसका मतलब ह ै क्रक सब-असेंबली या इलेक्ट्ॉवनक वडिाइस में आरिंभ क्रकए गए प्रत्येक काम या डेटा में बदलाि के वलए प्रत्येक कमािंड का एक साफ और वनवित सिंबिंध होता ह।ै रटप्पण: अगर "विवधक रूप से सुसिंगत " सब-असेंबली या इलेक्ट्ॉवनक वडिाइस दसू रे "विवधक रूप से ससु िंगत " सब- असेंबली या इलेक्ट्ॉवनक वडिाइस के साथ इिंटरैक्ट करते हैं, तो 3(6)(vii) देखें। उदाहरण:
1) विद्यतु मीटर का सॉफ्टिेयर [ऊपर 3(6)(फ)(क) का उदाहरण देखें] आिश्यक मात्राओं का चयन करन े के वलए कमािंड प्राप्त करने म ें सक्षम ह।ै यह माप मान को अवतररक्त र्ानकारी के साथ र्ोड़ता ह ै – र्ैस े समय स्टा्प, इकाई – और इस डेटा सेट को अनुरोध करने िाले वडिाइस को िापस भेर्ता ह।ै सॉफ्टिेयर केिल मान्य अनुमत मात्राओं के चयन के वलए कमािंड स्िीकार करता ह ै और क्रकसी भी अन्य कमािंड को हटा दते ा ह,ै केिल एक त्रुरट सिंदेश िापस भेर्ता ह।ै डेटा सेट की सामग्री के वलए सुरक्षा के साधन हो सकते ह,ैं लेक्रकन िे आिश्यक नहीं ह,ैं क्योंक्रक प्रेवषत डटे ा सेट विवधक वनयिंत्रण के अधीन नहीं ह।ै
2) सील क्रकए र्ा सकने िाल े आिरण के अिंदर एक वस्िच होता ह ै र्ो विद्युत मीटर के सिंचालन मोड को पररभावषत करता ह:ै एक वस्िच सेटटिंग सत्यावपत मोड को इिंवगत करती ह ै और दसू री गैर-सत्यावपत मोड को (यािंवत्रक सील के अवतररक्त अन्य सुरक्षा साधन भी सिंभि हैं; 3(6)(iii)(ख)(खग) में उदाहरण देखें)। प्राप्त कमािंड की व्याख्या करते समय सॉफ़्टिेयर वस्िच की वस्थवत की र्ाँच करता ह:ै गैर-प्रमावणत मोड में सॉफ़्टिेयर द्वारा स्िीकार क्रकया र्ाने िाला कमािंड सेट ऊपर िर्णात मोड की तुलना में विस्ताररत होता है; उदाहरण के वलए, यह सिंभि हो सकता ह ै क्रक एक कमािंड द्वारा अिंशािंकन कारक को समायोवर्त क्रकया र्ाए वर्से प्रमावणत मोड में खाररर् कर क्रदया र्ाता ह।ै[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 25
(vi) सॉफ्टिेयर पाटा को अलग करना,– (क) सभी सॉफ़्टिेयर मॉड्यूल (प्रोग्राम, सबरूटीन, ऑब्र्ेक्ट आक्रद) र्ो विवधक रूप से ससु िंगत काया करत ेह ैंया वर्नमें विवधक रूप से सुसिंगत डेटा डोमेन होत ेहैं, िे एक विद्युत मीटर के विवधक रूप स ेसुसिंगत सॉफ़्टिेयर भाग का वनमााण करते ह,ैं वर्से 3(6) (ii) में िर्णात अनुसार पहचानने योग्य बनाया र्ाना चावहए। यक्रद विवधक रूप से सुसिंगत काया करन े िाले सॉफ़्टिेयर मॉड्यूल की पहचान नहीं की र्ाती है, तो पूरे सॉफ़्टिेयर को विवधक रूप से सुसिंगत माना र्ाएगा। (ख) यक्रद विवधक रूप से सुसिंगत सॉफ़्टिेयर भाग अन्य सॉफ़्टिेयर भागों के साथ सिंचार करता है, तो एक सॉफ़्टिेयर इिंटरफेस पररभावषत क्रकया र्ाना चावहए। सभी सिंचार विशेष रूप से इस इिंटरफेस के माध्यम स े ही क्रकया र्ाना चावहए। विवधक रूप से ससु िंगत सॉफ़्टिेयर भाग और इिंटरफेस को स्पष्ट रूप से प्रलेवखत क्रकया र्ाना चावहए। सॉफ़्टिेयर के सभी विवधक रूप से सुसिंगत फिंक्शन और डेटा डोमेन का िणान क्रकया र्ाना चावहए ताक्रक एक प्रकार अनुमोदन प्रावधकरण सही सॉफ़्टिेयर पृथक्करण पर वनणाय ले सके। (ग) सॉफ्टिेयर इिंटरफेस बनाने िाले डेटा डोमेन, वर्सम ें विवधक रूप से सुसिंगत भाग से इिंटरफेस डेटा डोमेन में वनयाात करने िाला कोड और इिंटरफेस से विवधक रूप स े सुसिंगत भाग में आयात करने िाला कोड शावमल ह,ै को स्पष्ट रूप से पररभावषत और प्रलेवखत क्रकया र्ाना चावहए। घोवषत सॉफ्टिेयर इिंटरफेस को पररििंचना नहीं क्रकया र्ाना चावहए। (घ) सॉफ़्टिेयर के विवधक रूप से महत्िपूणा भाग में, शुरू क्रकए गए सभी कृत्प या डेटा में होने िाले बदलािों के वलए हर कमािंड का स्पष्ट असाइनमेंट होना चावहए। सॉफ़्टिेयर इिंटरफेस के ज़ररए क्युवनकेट करन े िाले कमािं्स को घोवषत और दस्तािेर्ीकृत क्रकया र्ाना चावहए। सॉफ़्टिये र इिंटरफेस के ज़ररए केिल दस्तािेर्ीकृत क्रकए गए कमािं्स को ही सिंक्रिवयत करने की अनुमवत ह।ै विवनमााता को कमािं्स के प्रलेखन की पूणाता के बारे में बताना होगा।
(vii) डेटा का स्टोरेर्, सिंचार प्रणाली के माध्यम से सिंचरण,– (क) सामान्य.– अगर माप के मान का उपयोग माप िाली र्गह के अवतररक्त क्रकसी दसू री र्गह पर या माप के समय के बाद क्रकया र्ाता ह,ै तो विवधक कामों के वलए प्रयोग होने स े पहले उन्ह ें मीटर (इलेक्ट्ॉवनक वडिाइस, सब-असेंबली) स े बाहर वनकालकर क्रकसी असरु वक्षत माहौल में स्टोर या सचिं ाररत करना पड़ सकता ह।ै ऐसे में वनम्नवलवखत शतें लाग ू होती ह:ैं (कक) स्टोर या सिंचाररत क्रकए गए माप के मान के साथ भविष्य में विवधक तौर पर आिश्यक प्रयोग के वलए सभी ज़रूरी र्ानकारी होनी चावहए। (कख) डेटा को सॉफ्टिेयर के माध्यम स े सरु वक्षत क्रकया र्ाना चावहए ताक्रक र्ानकारी की प्रमावणकता, अखिंडता और ज़रूरत पड़ने पर माप के समय की सटीकता की गारिंटी दी र्ा सके। र्ो सॉफ्टिेयर माप के मान और उससे र्ुड़े डेटा को क्रदखाता ह ै या आगे प्रसिंस्कृत करता है, उस े असुरवक्षत स्टोरेर् से पढने या असरु वक्षत पररषण चैनल से वमलने के बाद माप के समय, प्रमावणकता और डेटा की अखिंडता की र्ािंच करनी चावहए। अगर कोई गड़बड़ी वमलती है, तो डेटा को हटा क्रदया र्ाना चावहए या उपयोग के योग्य नहीं माना र्ाना चावहए। डेटा को सरु वक्षत रखने के वलए प्रयोग की र्ाने िाली गोपनीय कुिंवर्यों को गुप्त रखा र्ाना चावहए और विद्युत मीटर म ें26 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] सुरवक्षत रखना चावहए। ऐसी व्यिस्था होनी चावहए क्रक इन कुिंवर्यों को तभी इनपुट या पढा र्ा सके र्ब सील तोड़ी र्ाए। (कग) र्ो सॉफ्टिेयर मॉड्यूल डेटा को स्टोर या भेर्न े के वलए तैयार करते हैं, या पढने या वमलन े के बाद डेटा की र्ािंच करते ह,ैं िे विवधक तौर पर सुसिंगत सॉफ्टिेयर का वहस्सा होते ह।ैं (ख) ऑटोमैरटक स्टोटरिंग (खक) र्ब डेटा स्टोरेर् की अपेवक्षत हो, तो माप पूरा होन ेपर, अथाात ्अिंवतम मान सृर्न होन ेपर माप डेटा ऑटोमैरटकली स्टोर होना चावहए। र्ब अिंवतम मान क्रकसी गणना से हो, तो गणना के वलए ज़रूरी सभी डेटा अिंवतम मान के साथ ऑटोमैरटकली स्टोर होना चावहए। (खख) स्टोरेर् वडिाइस में इतना स्कावयत्ि होना चावहए क्रक सामान्य स्टोरेर् किंडीशन में डेटा खराब न हो। क्रकसी खास एवप्लकेशन के वलए काफी ममे ोरी स्टोरेर् होनी चावहए। (खग) स्टोर क्रकया गया डेटा तब हटाया र्ा सकता ह ै र्ब:
• ट्ािंज़ैक्शन पूरा हो र्ाए, या • यह डेटा क्रकसी ऐसे लप्रिंटटिंग वडिाइस से लप्रिंट क्रकया र्ाए र्ो विवधक वनयिंत्रण के अधीन में हो। • रटप्पण: यह वनयम सिंचयी रवर्स्टर और ऑवडट ट्ेल पर लागू नहीं होगा। (खघ) र्ब 3(6)(vii)(ख)(खग) में बताई गई अपेक्षाए िं परू ी हो र्ाएिं और स्टोरेर् भर र्ाए, तो स्टोर क्रकए गए डटे ा को हटाने की अनुमवत ह,ै र्न नीचे दी गई दोनों शतें पूरी हों:
• डेटा को उसी िम में हटाया र्ाए वर्स िम में उसे ररकॉड ा क्रकया गया था और उस खास एप्लीकेशन के वलए तय वनयमों का पालन क्रकया र्ाए; • डेटा हटाने का काम या तो स्ितः हो या क्रकसी खास मनै ुअल ऑपरेशन के माध्यम से क्रकया र्ाए, वर्सके वलए विशेष पहुचिं अवधकारों की ज़रूरत हो सकती ह।ै (ग) डाटा पररषण,– (गक) पररषण में देरी की िर्ह से माप पर कोई गलत असर नहीं पड़ना चावहए। (गख) अगर नेटिका सर्िास उपलब्ध न हों, तो भी विवधक रूप से ज़रूरी कोई भी माप डेटा खोना नहीं चावहए। (घ) टाइम स्टै्प.– टाइम स्टै्प को वडिाइस की घड़ी स े पढा र्ाएगा। घड़ी की सेटटिंग को विवधक रूप स े महत्िपूणा माना र्ाता ह।ै 3(6)(iv) के अनुसार सुरक्षा के उवचत उपाय क्रकए र्ाएिंगे।[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 27 र्ब क्रकसी खास क्षेत्र (र्ैस े मल्टी-टैररफ मीटर, इिंटरिल मीटर) के वलए माप का समय ज़रूरी हो, तो आिंतररक घवड़यों की अवनवितता को कम करने के वलए उन्ह ें विशेष तरीकों (र्सै े सॉफ्टिेयर के माध्यम से) से बेहतर बनाया र्ा सकता ह।ै
(viii) रखरखाि और री-कॉवन्फगरेशन.– फील्ड में विद्युत मीटर के विवधक रूप स े आिश्यक सॉफ़्टिेयर को अपडेट करन े को इस तरह माना र्ाना चावहए: • विद्युत मीटर में बदलाि, र्ब सॉफ़्टिेयर को क्रकसी दसू रे स्िीकृत िर्ान से बदला र्ाए, या • विद्युत मीटर की मर्मत, र्ब उसी िर्ान को दोबारा इिंस्टॉल क्रकया र्ाए। वर्स विद्यतु मीटर में सेिा के दौरान बदलाि या मर्मत की गई हो, उसका दोबारा सत्यापन ज़रूरी होगा। सॉफ़्टिेयर अपडेट करने की सुविधा को ऐसी सेटटिंग (र्ैसे क्रफवज़कल वस्िच या सुरवक्षत पैरामीटर) से बिंद क्रकया र्ाना चावहए वर्से सील क्रकया र्ा सके, ताक्रक सील तोड़े वबना विवधक रूप से ज़रूरी सॉफ़्टिये र को अपडेट करना सिंभि न हो। र्ो सॉफ़्टिेयर विद्यतु मीटर के सही ढिंग स े काम करने के वलए आिश्यक नहीं ह,ै उसे अपडेट करने के बाद सत्यापन की ज़रूरत नहीं होती। (क) केिल विवधक रूप से आिश्यक सॉफ्टिेयर के उन िर्ान का उपयोग क्रकया र्ा सकता ह ै र्ो स्िीकृत क्रकए गए प्रकार के अनुरूप हों। यह मामला फील्ड में सत्यापन से र्ुड़ा ह।ै (ख) सत्यावपत अपडेट.– वर्स सॉफ्टिेयर को अपडेट करना ह,ै उसे लोकल तौर पर अथाात् सीध े मापने िाले वडिाइस पर या नेटिका के माध्यम से दरू से लोड क्रकया र्ा सकता ह।ै टेक्रिकल सॉल्यूशन की आिश्यकताओं के आधार पर, लोलडिंग और इिंस्टॉलेशन दो अलग-अलग चरण हो सकते ह ैं या एक ही चरण में वमलाए र्ा सकत े ह।ैं अपडेट क्रकतना असरदार ह,ै यह र्ािंचन े के वलए विद्युत मीटर की इिंस्टॉलेशन साइट पर क्रकसी व्यवक्त का विद्यमान होना आिश्यक ह।ै विद्युत मीटर के विवधक रूप स े आिश्यक सॉफ्टिेयर को अपडेट करन े (क्रकसी दसू रे स्िीकृत िर्ान स े बदलने या दोबारा इिंस्टॉल करने) के बाद, उपस्करका सत्यापन क्रकए वबना और वसक्योररटी के तरीकों को निीकृत क्रकए वबना विद्युत मीटर का प्रयोग विवधक कामों के वलए नहीं क्रकया र्ा सकता। (ग) ट्ेस्ड अपडेट.– सॉफ्टिेयर को ट्ेस्ड अपडेट (गक से गछ) की आिश्यकताओं के अनुसार उपस्कर में लागू क्रकया र्ाता ह।ै ट्ेस्ड अपडेट एक सत्यावपत उपस्करया वडिाइस में सॉफ्टिेयर बदलने की प्रक्रिया है, वर्सके बाद साइट पर क्रकसी वज़्मेदार व्यवक्त द्वारा बाद में सत्यापन करन े की ज़रूरत नहीं होती। वर्स सॉफ्टिेयर को अपडेट करना है, उस े स्थानीय तौर पर अथाात ् सीध े मापने िाले वडिाइस पर या नेटिका के माध्यम स े दरू स े लोड क्रकया र्ा सकता ह।ै सॉफ्टिेयर अपडेट को ऑवडट ट्ेल में ररकॉड ा क्रकया र्ाता ह।ै ट्ेस्ड अपडेट की प्रक्रिया में कई चरण शावमल होते ह:ैं लोलडिंग, इिंटीवग्रटी चके किंग, ओररवर्न की र्ाचिं (ऑथेंरटकेशन), इिंस्टॉलेशन, लॉलगिंग और एवक्टिेशन।28 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] (गक) सॉफ़्टिेयर का ट्ेस्ड अपडेट स्ितः होना चावहए। अपडेट की प्रक्रिया पूरी होने पर, सॉफ़्टिेयर सुरक्षा का स्तर िही होना चावहए र्ो टाइप अनुमोदन के वलए आिश्यक ह।ै (गख) टारगेट इलेवक्ट्वसटी मीटर (इलेक्ट्ॉवनक वडिाइस, सब-असेंबली) में विवधक रूप से आिश्यक सॉफ़्टिेयर वनयत होना चावहए वर्स े अपडेट न क्रकया र्ा सके और वर्समें ट्ेस्ड अपडेट की आिश्यकताओं को पूरा करने के वलए आिश्यक सभी चेककिंग फिंक्शन हों। (गग) लोड क्रकए गए सॉफ़्टिये र की प्रमावणकता की गारिंटी के वलए तकनीकी तरीकों को वनयोवर्त क्रकया र्ाना चावहए, अथाात् यह सुवनवित करना क्रक यह टाइप अनुमोदन प्रमाण-पत्र के मावलक की तरफ से आया ह।ै अगर लोड क्रकया गया सॉफ़्टिेयर प्रमावणकता की र्ाँच में असफल हो र्ाता है, तो उपस्करउसे हटा देगा और सॉफ़्टिेयर के वपछले िर्ान का उपयोग करेगा या ऐसे मोड में चला र्ाएगा वर्समें िह काम न कर सके। (गघ) लोड क्रकए गए सॉफ़्टिेयर की अखिंडता सुवनवित करने के वलए तकनीकी तरीकों का उपयोग क्रकया र्ाना चावहए, अथाात् यह सुवनवित करना क्रक लोड करन े स े पहल े उसमें कोई गलत बदलाि न क्रकया गया हो। यह लोड क्रकए गए सॉफ़्टिेयर का चेकसम या हशै कोड र्ोड़कर और लोलडिंग प्रक्रिया के दौरान उसे सत्यावपत करके क्रकया र्ा सकता ह।ै अगर लोड क्रकया गया सॉफ़्टिेयर इस परीक्षण में असफल हो र्ाता ह,ै तो उपस्करउस ेहटा दगे ा और सॉफ़्टिेयर के वपछले िर्ान का उपयोग करेगा या ऐस े मोड में चला र्ाएगा वर्समें िह काम न कर सके। इस मोड में, मापने िाले फिंक्शन रोक क्रदए र्ाएँगे। ट्ेस्ड अपडेट की प्रक्रिया में क्रकसी भी स्टेप को छोड़े वबना, डाउनलोड प्रक्रिया को क्रफर से शुरू करना ही सिंभि होगा। (गङ) विवधक रूप से महत्िपूणा सॉफ़्टिेयर के ट्ैक क्रकए गए अपडेट को बाद में सत्यापन और वनगरानी या वनरीक्षण के वलए उपस्करके भीतर ठीक से ट्ैक क्रकया र्ा सके, यह सवु नवित करन े के वलए उवचत तकनीकी साधनों र्सै े ऑवडट ट्ेल का उपयोग क्रकया र्ाएगा। ऑवडट ट्ेल में कम स े कम ये र्ानकारी होनी चावहए: अपडेट प्रक्रिया की सफलता/असफलता, इिंस्टॉल क्रकए गए िर्ना की सॉफ़्टिेयर पहचान, पहले इिंस्टॉल क्रकए गए िर्ान की सॉफ़्टिेयर पहचान, घटना का टाइम स्टै्प, डाउनलोड करने िाल े की पहचान। सफलता या असफलता की परिाह क्रकए वबना, हर अपडेट कोवशश के वलए एक एिंट्ी बनाई र्ाएगी। ट्ैक क्रकए गए अपडेट को सपोटा करने िाल े स्टोरेर् वडिाइस में इतनी क्षमता होनी चावहए क्रक िह फील्ड/वनरीक्षण म ें लगातार दो सत्यापन के बीच विवधक रूप से महत्िपूणा सॉफ़्टिेयर के ट्ैक क्रकए गए अपडेट की ट्ेसेवबवलटी सुवनवित कर सके। ऑवडट ट्ेल के वलए स्टोरेर् की सीमा तक पहुचँ ने के बाद, तकनीकी साधनों से यह सुवनवित क्रकया र्ाएगा क्रक सील तोड़े वबना आगे कोई डाउनलोड न हो सके। रटप्पण: यह अपेक्षा वनरीक्षण अवधकाररयों को र्ो विवधक रूप स े वनयिंवत्रत उपस्करकी विवधक माप-विज्ञानी वनगरानी के वलए वज़्मेदार ह ैं - एक उवचत समय अिवध में विवधक रूप से महत्िपूणा सॉफ़्टिेयर के ट्ैक क्रकए गए अपडेट को बैक-ट्ेस करने में सक्षम बनाती ह।ै[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 29 (गच) यह माना र्ाता ह ैक्रक विद्युत मीटर बनाने िाली किंपनी अपने ग्राहक को सॉफ़्टिये र अपडेट, विशेषकर विवधक रूप से ज़रूरी भागो के बारे में पूरी र्ानकारी देती ह,ै और ग्राहक अपडेट लेने से मना नहीं करेगा। साथ ही, यह भी माना र्ाता ह ै क्रक बनाने िाली किंपनी और ग्राहक, उपयोग करन े िाले या मीटर के मावलक, मीटर के उपयोग और र्गह के आधार पर डाउनलोड करन े के सही तरीके पर सहमत होंगे। (गछ) यक्रद 3(6)(viii)(ग)(गक) से 3(6)(viii)(ग)(गर्) तक की आिश्यकताओं को पूरा नहीं क्रकया र्ा सकता है, तो भी विवधक रूप से अससु िंगत सॉफ़्टिेयर भाग को अपडेट करना सिंभि ह।ै इस मामले में, वनम्नवलवखत आिश्यकताओं को पूरा क्रकया र्ाना चावहए:
• विवधक रूप से सुसिंगत और असुसिंगत सॉफ़्टिेयर के बीच स्पष्ट अिंतर है; • सील तोड़े वबना विवधक0 रूप से सुसिंगत सॉफ़्टिेयर के पूरे वहस्से को अपडेट नहीं क्रकया र्ा सकता; • प्रकार अनुमोदन प्रमाणपत्र में यह उल्लेख क्रकया गया ह ै क्रक विवधक रूप स े असुसिंगत वहस्से को अपडेट करना स्िीकाय ा ह।ै
(ix) सुविधा कायािम ररकॉडा की समीक्षा– यक्रद मीटर में र्ाँच की सुविधा उपलब्ध है, तो उस सुविधा के इिेंट ररकॉडा म ें कम से कम 100 इिेंट्स की क्षमता होनी चावहए और यह 'फस्टा-इन-फस्टा-आउट' प्रकार का होना चावहए। सील तोड़े वबना और/या अवधकृत एक्सेस उदाहरण के वलए, कोड (पासिडा) या क्रकसी विशेष वडिाइस (हाडा) की आक्रद के माध्यम से, के वबना इिेंट ररकॉडा को बदला या शून्य नहीं क्रकया र्ा सकता ह।ै
(7) उपयोग के वलए उपयुक्तता,-
(i) पररणाम की सुपाठ्यता– मीटर में एक (अथिा एक से अवधक) सिंकेतक उपस्करहोने चावहए, र्ो उस प्रत्येक विवधक मापन इकाई का सिंख्यात्मक मान प्रदर्शात करने में सक्षम हों, वर्सके वलए मीटर को अनुमोक्रदत क्रकया गया ह।ै सकिं ेतक उपस्करको पढना सरल होना चावहए तथा मापन पररणामों को प्रदर्शात करने िाले अक्षरों की ऊँचाई न्यूनतम 4 वममी होनी चावहए। क्रकसी भी दशमलि अिंश को स्पष्ट रूप से प्रदर्शात क्रकया र्ाना चावहए; यािंवत्रक रवर्स्टरों के मामले में दशमलि अिंश दशााने िाले ड्रम को अन्य ड्रमों से वभन्न प्रकार से वचवननत क्रकया र्ाना चावहए। मीटर के अवधकतम र्ीिनकाल के दौरान सामान्य पररचालन वस्थवतयों के सिंपका में आने से सकिं ेतक उपस्करमहत्िपूणा रूप से प्रभावित नहीं होना चावहए। सिंकेतक उपस्कर वबललिंग के उद्देश्य से आिश्यक सभी आिंकड़ो को प्रदर्शात करने में सक्षम होना चावहए। यक्रद एक ही सकिं ेतक उपस्करद्वारा एकावधक मान प्रदर्शात क्रकए र्ाते हैं, तो उससे सिंबिंवधत सभी सुसिंगत स्मृवतयों की सामग्री को प्रदर्शात करना सिंभि होना चावहए। स्िचावलत अनुिमण प्रदशान की वस्थवत में, वबललिंग प्रयोर्नों हते ु प्रत्येक रवर्स्टर के प्रदशान को न्यूनतम 5 सके िंड तक प्रदर्शात रखा र्ाना चावहए। बहु-दर मीटरों के वलए, सक्रिय दर को दशाान ेिाले रवर्स्टर को इिंवगत क्रकया र्ाना चावहए। प्रत्येक दर रवर्स्टर को स्थानीय रूप से पढना सिंभि होना चावहए और प्रत्येक रवर्स्टर की स्पष्ट पहचान होनी चावहए।30 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] इलेक्ट्ॉवनक रवर्स्टर नॉन-िोलाटाइल होने चावहए ताक्रक विद्युत र्ाने पर भी उनम ेंस्टोर की गई िैल्यू बनी रह।े स्टोर की गई िैल्यू ओिरराइट नहीं होनी चावहए और विद्युत िापस आने पर उन्ह ें क्रफर स े प्राप्त क्रकया र्ा सके। रवर्स्टर में इतनी ऊर्ाा स्टोर करने और क्रदखाने की क्षमता होनी चावहए र्ो P = Unom·I max·n पर कम से कम 4000 घिंटे तक चलन े िाले मीटर के बराबर हो, र्हाँ n फेज़ की सिंख्या ह।ै भिंडारण और प्रदशान की यह क्षमता वबललिंग के वलए सुसिंगत सभी रवर्स्टरों पर लागू होती है, वर्समें वद्व-क्रदशात्मक मीटरों के वलए सकारात्मक और नकारात्मक प्रिाह रवर्स्टर और बहु- टैररफ मीटरों के वलए टैररफ रवर्स्टर शावमल ह।ैं इलेक्ट्ॉवनक रवर्स्टरों के मामले में, वडस्कनेक्ट क्रकए गए मीटर के पररणामों के वलए न्यूनतम प्रवतधारण समय एक िषा ह।ै इलेक्ट्ॉवनक सिंकेत दने े िाले उपकरणों में एक वडस्प्ले टेस्ट प्रदान क्रकया र्ाना चावहए र्ो यह वनधारा रत करने के उद्देश्य से सभी वडस्प्ले सेगमेंट को चाल ू और क्रफर बिंद कर दे क्रक क्या सभी वडस्प्ले सेगमेंट काम कर रह े ह।ैं
(ii) परीक्षण-योग्यता– मीटर में प्रभािी परीक्षण हते ु एक परीक्षण आउटपुट उपलब्ध होना चावहए, र्सै े क्रक वचनन युक्त रोटर अथिा परीक्षण पल्स आउटपुट । यक्रद परीक्षण आउटपुट की अवभकल्पना ऐसी हो क्रक प्रत्येक ससु िंगत समय अिंतराल में पल्स दर मापी गई शवक्त के अनुरूप न हो, तो विवनमााता को आिश्यक पल्सों की सिंख्या घोवषत करनी होगी, वर्ससे I , Itr तथा I पर मापन का मानक विचलन अवधकतम अनुमेय त्रुरट के 0.1 स े कम अवधकतम न्यूनतम सुवनवित क्रकया र्ा सके। परीक्षण आउटपुट द्वारा दी गई मापी गई ऊर्ाा और सिंकेतक उपस्करद्वारा दी गई मापी गई ऊर्ाा के बीच का सिंबिंध नेम- प्लेट पर अिंक्रकत मार्किंग के अनुरूप होना चावहए। वसग्नल भर्े ने िाल े वसस्टम से वनकलने िाल े वसग्नल की िेिलेंथ 550 और 1,000 के बीच होनी चावहए। नैनोमीटर नैनोमीटर मीटर में लगा आउटपुट वडिाइस, मीटर की सतह स े 10 ±1 की दरू ी पर एक तय रेफरेंस सतह (ऑवप्टकली वममी वममी एवक्टि एररया) पर E रेवडएशन स्ट्ेंथ िाला वसग्नल बनाएगा, वर्सकी वलवमटटिंग िैल्यू इस प्रकार होंगी:
T ऑन-वस्थवत: 50μW/cm2 ≤ ET ≤ 7500μW/cm2 ऑफ-वस्थवत: ET ≤ 2μW/cm2
(8) रटकाऊपन– मीटर को विवनमााता द्वारा वनर्दाष्ट अिवध के वलए अपनी मापविज्ञान विशेषताओं की पयााप्त वस्थरता बनाए रखन े के वलए वडज़ाइन क्रकया र्ाना चावहए, परन्तु क्रक इसे विवनमााता के वनदेशों के अनुसार ठीक स े स्थावपत, रखरखाि और उपयोग क्रकया र्ाए, र्ब यह उन पयाािरणीय वस्थवतयों में हो वर्सके वलए इसे अवभप्रेत क्रकया गया ह।ै वनमााता को स्थावयत्ि के दाि े का समथना करने के वलए साक्ष्य प्रदान करना होगा। मीटर को इस तरह वडज़ाइन क्रकया र्ाना चावहए क्रक गलत माप पररणाम देने िाली खराबी के प्रभाि को यथासभिं ि कम क्रकया र्ा सके। मीटर को इस तरह वडज़ाइन और वनर्मात क्रकया र्ाना चावहए क्रक क) रटकाऊपन सिंबिंधी कोई बड़ी खराबी न आए, या[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 31 ख) रटकाऊपन सिंबिंधी बड़ी खराबी का पता लगाकर रटकाऊपन सुरक्षा द्वारा उस पर कारािाई की र्ाए।
(9) अनुपालन की मान्यता – यक्रद मीटर इस अवधसूचना के भाग 2 में वनर्दाष्ट परीक्षा और परीक्षणों को उत्तीणा करता ह,ै तो यह माना र्ाता ह ै क्रक िह खिंड 3 के उपबिंधों का अनुपालन करता ह।ै भाग 2 माप-विज्ञान वनयिंत्रण और प्रदशान परीक्षण
4. प्रकार अनुमोदन –
(1) प्रलेखीकरण – प्रकार अनुमोदन के आिेदन के साथ प्रस्ततु क्रकए र्ाने िाले दस्तािेज़ों में वनम्नवलवखत शावमल होंगे: • प्रकार की पहचान, वर्समें शावमल ह ैं ▪ नाम या ट्ेडमाका और प्रकार का वििरण, ▪ हाडािेयर और सॉफ़्टिेयर का सिंस्करण, ▪ नेम प्लेट का वचत्र;
• मीटर की माप-सिंबिंधी विशेषताएिं, वर्नमें शावमल ह:ैं ▪ माप के वसद्ािंत (वसद्ातिं ों) का वििरण, ▪ माप-सिंबिंधी विवनदेश र्ैसे सटीकता िगा और रेटेड ऑपरेटटिंग वस्थवतयािं (खिंड 3(1)), ▪ मीटर का परीक्षण करने से पहले क्रकए र्ाने िाले कोई भी कदम;
• मीटर के वलए तकनीकी विवनदेश, वर्समें शावमल ह:ैं ▪ घटकों और उपकरणों के कायाात्मक वििरण के साथ एक ब्लॉक आरेख, ▪ वनमााण और सचिं ालन की व्याख्या करन े िाले वचत्र, आरेख और सामान्य सॉफ़्टिेयर र्ानकारी, वर्समें इिंटरलॉक शावमल ह,ैं ▪ सील या सरु क्षा के अन्य साधनों का वििरण और वस्थवत, ▪ स्थावयत्ि विशेषताओं से सिंबिंवधत दस्तािेज़, ▪ कोई भी दस्तािेज़ या अन्य सबूत क्रक मीटर का वडज़ाइन और वनमााण इस अवधसूचना की आिश्यकताओं को पूरा करता है, ▪ वनधााररत क्लॉक फ़्रीवेंसी, ▪ मीटर की ऊर्ाा खपत;
• यूज़र मैनुअल; • इिंस्टॉलेशन मैनुअल;32 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] • यक्रद लागू हो, तो महत्िपूणा दोषों के वलए र्ाचँ सुविधा का वििरण; इसके अवतररक्त, सॉफ़्टिेयर दस्तािेज़ीकरण में शावमल होना चावहए • विवधक रूप से ससु िंगत सॉफ़्टिेयर का वििरण और आिश्यकताओं को कैसे पूरा क्रकया र्ाता ह:ै ▪ विवधक रूप से ससु िंगत भागों से सिंबिंवधत सॉफ्टिेयर मॉड्यूल की सूची, साथ ही एक घोषणा क्रक सभी विवधक रूप से ससु िंगत काया वििरण में शावमल हैं;
▪ विवधक रूप से ससु िंगत सॉफ्टिेयर भाग के सॉफ्टिेयर इिंटरफेस और इस इिंटरफेस के माध्यम से कमािंड और डेटा प्रिाह का वििरण, वर्समें पूणाता का वििरण भी शावमल ह;ै ▪ सॉफ़्टिेयर पहचान के वनमाणा का वििरण; ▪ सुरवक्षत क्रकए र्ाने िाले पैरामीटर की सूची और सुरक्षा के तरीकों का वििरण;
• ऑपरेटटिंग वसस्टम की सुरक्षा व्यिस्था का वििरण (र्ैस े पासिडा आक्रद, अगर लागू हो); (सॉफ्टिेयर) सीललिंग के तरीकों का वििरण; • वसस्टम हाडािेयर का अिलोकन, र्सै े टोपोलॉर्ी ब्लॉक डायग्राम, किंप्यूटर का प्रकार, नेटिका का प्रकार आक्रद । • र्हाँ कोई हाडािेयर किंपोनेंट विवधक रूप से महत्िपूणा माना र्ाता ह ै या र्हा ँ िह विवधक रूप से महत्िपूणा काम करता ह,ै िहाँ उसकी भी पहचान की र्ानी चावहए;
• एल्गोररदम की सटीकता का वििरण (र्ैसे ए/डी रूपािंतरण पररणामों की क्रफल्टटरिंग, मूल्य गणना, राउिंलडिंग एल्गोररदम, आक्रद); • उपयोगकताा इिंटरफेस, मेनू और सिंिादों का वििरण; • सॉफ़्टिेयर की पहचान और उपयोग में मौर्ूद उपस्करसे इसे प्राप्त करन े के वलए वनदशे ;
• मापने िाले उपस्कर/ इलेक्ट्ॉवनक के हर हाडािेयर इिंटरफेस के कमािं्स की वलस्ट • उपस्कर/ उप-सिंयोर्न वर्समें पूणाता का वििरण शावमल हो; • सॉफ्टिेयर द्वारा पता लगाई गई स्थावयत्ि त्रुरटयों की सूची और, यक्रद समझने के वलए आिश्यक हो, तो पता लगाने िाले एल्गोररदम का वििरण;
▪ सिंग्रहीत या प्रसाररत आँकड़ा समुच्चयका वििरण; ▪ यक्रद सॉफ़्टिेयर में त्रुरटया ससिं ूचन की सुविधा ह,ै तो पता लगाए गए त्रुरटयों की सूची और त्रुरट का ससिं ूचन एल्गोररदम का वििरण; ▪ प्रचालन पुवस्तका ।[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 33 इसके अवतररक्त, यक्रद प्रकार अनुमोदन मौर्ूदा प्रकार परीक्षण दस्तािेज़ों पर आधाररत है, तो टाइप अनुमोदन के आिेदन के साथ िे दस्तािेज़ या अन्य साक्ष्य सिंलग्न होने चावहए र्ो इस बात का समथान करते हों क्रक मापन युक्रि का अवभकल्प और विशेषताएिं इस अवधसचू ना की आिश्यकताओं का अनुपालन करते ह।ैं
(2) प्रकार की पररभाषा– एक ही विवनमााता द्वारा वनर्मता मीटर एक प्रकार बना सकते हैं, यक्रद उनके माप-सिंबिंधी गुण धमा हों, र्ो उन भागों/मॉड्यूल के समान वनमााण के उपयोग से उत्पन्न होत े ह ैंर्ो माप-सिंबिंधी गुणधमो को वनधााररत करत े ह।ैं क्रकसी प्रकार म ें करिंट की कई रेंर् और नाममात्र िोल्टेर् ि आिृवत्त के कई मान हो सकत े हैं, और इसमें कई कनेक्शन मोड ि कई सहायक युक्रिया शावमल हो सकते ह।ैं रटप्पण: समान बनािट का सामान्यतः अथा ह:ै मापन अियिों की समान बनािट, मीटटरिंग सॉफ़्टिेयर की समान बनािट, रवर्स्टर और सिंकेतक युवक्त की समान बनािट, तापमान क्षवतपूर्त ा तिंत्र की समान बनािट, और केस, टर्मानल ब्लॉक ि यािंवत्रक अिंतरफलक की समान बनािट।
(i) प्रकार परीक्षण नमूनाकरण– विवनमााता को मीटर के कम से कम उतने नमनू े उपलब्ध कराने होंगे वर्तने परीक्षण के वलए आिश्यक हों। प्रकार परीक्षण मीटर के एक या अवधक नमूनों पर क्रकया र्ाएगा, वर्नका चयन प्रकार परीक्षण करन े िाली सिंस्था द्वारा क्रकया र्ाएगा, ताक्रक इसकी विवशष्ट विशेषताओं को स्थावपत क्रकया र्ा सके और इस अवधसूचना की आिश्यकताओं के अनरूु प होने को प्रमावणत क्रकया र्ा सके।
(3) विवधमान्यकरण.– विवधमान्यकरण में विश्लेषण विवधयों और परीक्षणों का सिंयोर्न शावमल है, र्ैसा क्रक सारणी 6 म ें क्रदखाया गया ह।ै उपयोग क्रकए गए सिंवक्षप्त रूप सारणी 7 में िर्णात ह।ैं सारणी 6 विवनर्दाष्ट आिश्यकताओं के वलए विवधमान्यकरण आिश्यकता विवधमान्यकरण सॉफ़्टिेयर की पहचान 3(6)(ii) एडी + िीएफटीएसडब्ल्यू गलत इस्तेमाल से बचाि 3(6)(iii)(क) एडी + िीएफटीएसडब्ल्यू कपट सिंरक्षण 3(6)(iii)(ख) एडी + िीएफटीएसडब्ल्यू पैरामीटर सिंरक्षण 3(6)(iv) एडी + िीएफटीएसडब्ल्यू34 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] 3(6)(v) इलेक्ट्ॉवनक युवक्तयो और उप-सिंयोर्नों का पृथक्करण एडी 3(6)(vi) सॉफ्टिेयर के विवभन्न घटक को अलग करना एडी डेटा का स्टोरेर्, क्युवनकेशन वसस्टम के ज़ररए ट्ािंसवमशन 3(6)(vii) एडी + िीएफटीएसडब्ल्यू 3(6)(vii)(क)(कख माप के समय के अनुसार आकँ ड़ा सिंरक्षण ) एडी + िीएफटीएसडब्ल्यू स्िचावलत सिंग्रहण 3(6)(vii)(ख) एडी + िीएफटीएसडब्ल्यू सिंचरण में विलिंब 3(6)(vii)(ग)(गक) एडी + िीएफटीएसडब्ल्यू प्रसारण में बाधा 3(6)(vii)(ग)(गक) एडी + िीएफटीएसडब्ल्यू समय की मुहर 3(6)(vii)(घ) एडी + िीएफटीएसडब्ल्य ू अनुरक्षण और पुनः विन्यास 3(6)(viii) एडी सारणी 7: सारणी 6 में प्रयुक्त विवधमान्यकरण प्रक्रिया के सिंवक्षप्त रूप सिंक्षेपाक्षर वििरण सिंबिंवधत अनुलग्नक ग एडी प्रलेखन का विश्लेषण और वडज़ाइन का पैरा 1 विवधमान्यकरण िीएफटीएसडब्ल्यू सॉफ्टिेयर कायों के प्रकायाात्मक परीक्षण द्वारा पैरा 2 विवधमान्यकरण
5. परीक्षण कायिा म– प्रारिंवभक अिंतर्नावहत त्रुरट का वनधारा ण मीटर पर पहले परीक्षण के रूप में क्रकया र्ाएगा, र्ैसा क्रक 6(2)(i) में िर्णात ह।ै परीक्षणों की क्रकसी भी श्रृिंखला की शुरुआत में, मीटर को विवनमााता द्वारा वनर्दाष्ट समय के वलए िोल्टेर् सर्काट सक्रिय[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 35 करके वस्थर होने क्रदया र्ाना चावहए। प्रारिंवभक अिंतर्नावहत त्रुरट के वलए परीक्षण लबिंदओंु का िम न्यूनतम धारा से अवधकतम धारा और क्रफर अवधकतम धारा स े न्यूनतम धारा तक होगा। प्रत्येक परीक्षण लबिंद ुके वलए, पररणामी त्रुरट इन मापों का औसत होगी। Imax के वलए, अवधकतम माप समय वस्थरीकरण समय सवहत 10 वमनट होगा। अिंतर्नावहत त्रुरट (सिंदभा पररवस्थवतयों में) का वनधाारण सदिै प्रभािकारी मात्राओं के परीक्षणों तथा उन विक्षोभ परीक्षणों से पूिा क्रकया र्ाएगा, र्ो त्रुरट में स्िीकाया विस्थापन (limit of error shift) की आिश्यकता अथिा त्रुरट से सिंबिंवधत क्रकसी महत्िपूणा त्रुरटयों की वस्थवत से सिंबद् हों। अन्यथा, परीक्षणों का िम वनधााररत नहीं ह।ै यथाथाता आिश्यकताओं के परीक्षण के वलए क्षवणक( विद्युत स्पिंदन) वनगाम का उपयोग क्रकया र्ा सकता ह।ै क्रफर यह सुवनवित करने के वलए एक परीक्षण क्रकया र्ाना चावहए क्रक आधारभूत ऊर्ा ा रवर्स्टर और उपयोग क्रकए गए टेस्ट वनगाम के बीच का सिंबिंध विवनमााता के विवनदेशों के अनरूु प ह।ै यक्रद क्रकसी मीटर को िैकवल्पक कनेक्शन मोड के साथ विवनर्दाष्ट क्रकया गया ह,ै र्ैसे क्रक पॉली-फेज़ मीटर के वलए एक- चरण कनेक्शन, तो सभी विवनर्दाष्ट कनेक्शन मोड के वलए 3(3)(iii) के अनुसार आधार अवधकतम स्िीकाया त्रुरट के परीक्षण क्रकए र्ाएिंगे। यक्रद आिश्यक हो, तो वनदेशक (विवधक मापविज्ञान) इस खिंड में िर्णात परीक्षण व्यिस्थाओं की तुलना में अवधक कड़े परीक्षण वनयम वनधााररत कर सकत े ह।ैं
6. प्रकार अनुमोदन के वलए परीक्षण प्रक्रियाएिं-
(1) परीक्षण की शतें– र्ब तक व्यवक्तगत परीक्षण अनुदेशों में अन्यथा न कहा गया हो, प्रकार अनुमोदन परीक्षणों के दौरान, परीक्षण की र्ा रही प्रभाि मात्रा को छोड़कर अन्य सभी प्रभाि मात्राओं को सारणी 8 में क्रदए गए सिंदभा शतों पर रखा र्ाएगा। सारणी 8 सिंदभा वस्थवतया ँ और उनकी सहनशीलता पररमाण सिंदभा वस्थवतयािं सहनशीलता िोल्टेर् (2) Unom ± 1 % पररिेशी तापमान 23 ºC(1) ± 2 ºC आिृवत्त fnom ± 0.3 % सिंकेत का समयनसु ार दश्ृ य रूप साइन तरिंगीय d ≤ 2 % सिंदभा आिृवत्त पर बाहरी उदगम का 0 T B ≤ 0.05 mT चुिंबकीय प्रेरण 30 kHz – 6 GHz विद्यतु चबुिं कीय 0 V/m ≤ 1 V/m रेवडयो-आिृवत्त क्षेत्र36 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] वस्थवत के प्रवत सिंिेदनशील यवु क्तयो विवनमााता के वनदेशानुसार माउिंटटिंग ± 0.5º के वलए प्रचालन वस्थवत बहु-फेज़ मीटरों के वलए फेज़ अनुिम L1, L2, L3 - भार सतिं ुलन सभी करिंट सर्काट में समान करिंट ± 2 % (करिंट) और ± 2º (कोणीय अिंतर )
(1) यक्रद प्रकार परीक्षणों में स्थावपत तापमान गुणािंक लाग ू करके पररणामों को सिंदभा तापमान में सही क्रकया र्ाता ह,ै और यक्रद उवचत अवनवितता विश्लेषण क्रकया र्ाता है, तो अन्य तापमानों पर परीक्षण क्रकए र्ा सकते ह।ैं
(2) यह आिश्यकता पॉली-फेज़ मीटरों के वलए फेज़-टू-फेज़ और फेज़-न्यूट्ल दोनों पर लागू होती है। रटप्पण: सिंदभा वस्थवतयािं और उनकी सहनशीलता परीक्षण प्रयोगशालाओं के बीच पुनरुत्पादकता सुवनवित करने के वलए दी गई ह,ैं न क्रक परीक्षणों की यथाथता ा वनधााररत करने के वलए। प्रभाि कारकों के वलए परीक्षण के दौरान कम समय की वस्थरता की मािंगें इस सारणी में क्रदखाए गए स्तर से बहुत अवधक हो सकती ह।ैं सारणी 9 परीक्षणों में भार की वस्थवतयाँ और उनकी सहनशीलता पररमाण वस्थवतया ँ सहनशीलता परीक्षण क्रकए र्ा रह े युवक्त की ितामान करिंट सीमा श्रेणी A, B: ± 2 % श्रेणी C, D: ± 1 % र्ािंचे र्ा रह े युवक्त की शवक्त गुणािंक शवक्त गुणक सीमा करिंट और िोल्टेर् के बीच फेज़ का अिंतर ± 2º रटप्पण: परीक्षण प्रयोगशालाओं के बीच पुनरुत्पादकता सुवनवित करने के वलए भार वस्थवतयों और उनकी सहनशीलता दी गई ह,ै न क्रक परीक्षणों की यथाथाता वनधााररत करने के वलए। प्रभाि कारकों के वलए परीक्षण के दौरान कम समय की वस्थरता की मािंगें सारणी 9 में क्रदखाए गए आिंकड़ों से बहुत अवधक हो सकती ह।ैं अवधकािंश परीक्षणों के वलए, यक्रद अन्य प्रभािकारी मात्राओं को सिंदभा वस्थवतयों पर वस्थर रखा र्ाता ह,ै तो मापी गई शवक्त वस्थर रहगे ी। हालाँक्रक, िोल्टेर् वभन्नता और भार असिंतुलन र्ैस े कुछ परीक्षणों के वलए यह सिंभि नहीं ह।ै इसवलए, त्रुरट बदलाि को हमेशा सापेक्ष त्रुरट के बदलाि के रूप में मापा र्ाना चावहए न क्रक पूणा शवक्त के रूप में।
(2) अवधकतम स्िीकाया त्रुरटयों के अनुपालन के वलए परीक्षण[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 37
(i) प्रारिंवभक अिंतर्नावहत त्रुरट का वनधारा ण- टेबल टेस्ट का उद्देश्य: यह सत्यावपत करन े के वलए क्रक सिंदभ ा वस्थवतयों में मीटर की त्रुरट, सारणी 2 में क्रदए गए प्रासिंवगक आधार एमपीई से कम ह।ै परीक्षण विवध: 3(3)(ii) में िर्णात, वद्वक्रदश या एकक्रदश ऊर्ाा मापन म ें सक्षम मीटरों को, ऊर्ाा प्रिाह की धनात्मक और ऋणात्मक दोनों क्रदशाओं के वलए सारणी 2 की प्रासिंवगक आधार एमपीई आिश्यकताओं को पूरा करना होगा। 3(3)(ii) में िर्णात, केिल धनात्मक ऊर्ाा प्रिाह को मापने में सक्षम मीटरों को धनात्मक ऊर्ाा प्रिाह के वलए सारणी 2 की प्रासिंवगक आधार एमपीई आिश्यकताओं को पूरा करना होगा। इन मीटरों को विपरीत ऊर्ा ाप्रिाह के अधीन भी क्रकया र्ाएगा, वर्सके र्िाब में मीटर को प्राथवमक रवर्स्टर में ऊर्ाा दर्ा नहीं करनी चावहए या परीक्षण वनगाम से एक से क्षवणक विद्युत स्पिंदन(पल्स) उत्सर्र्ात नहीं करनी चावहए। परीक्षण की अिवध न्यूनतम 1 वमनट होनी चावहए, अथिा िह समय र्ब परीक्षण वनगाम धनात्मक ऊर्ाा प्रिाह की क्रदशा में 10 पल्स दर्ा करे, अथिा िह समय र्ब प्राथवमक रवर्स्टर धनात्मक ऊर्ाा प्रिाह की क्रदशा में सबसे कम महत्िपूणा अिंक की 2 इकाइयाँ दर्ा करे, इनमें से र्ो भी अवधक हो। ऊष्मीकरण से प्रभावित होने की सिंभािना िाले ररिसा रलनिंग वडटेंट वडज़ाइनों के वलए, परीक्षण का समय Imax पर 10 वमनट तक बढाया र्ाना चावहए। आज्ञापक परीक्षण लबिंद:ु धनात्मक, ऋणात्मक और विपरीत प्रिाह परीक्षणों के वलए सारणी 10 म ें आज्ञापक परीक्षण लबिंद ुविवनर्दाष्ट ह।ैं सारणी 10 में वनर्दाष्ट अनुसार दो आज्ञापक परीक्षण लबिंद ुचुने र्ाएिंगे। धनात्मक, ऋणात्मक और विपरीत प्रिाह परीक्षणों के वलए सारणी 10 में आज्ञापक परीक्षण लबिंद ु वनर्दाष्ट ह।ैं सारणी 10 में विवनर्दाष्ट अनुसार दो आज्ञापक परीक्षण लबिंद ुचुने र्ाएगिं े। सारणी 10 अिंतर्नवा हत आिंतररक त्रुरट के वनधाारण हते ु आज्ञापक परीक्षण लबिंद ु करिंट शवक्त गुणक इनके वलए परीक्षण लबिंद ुआज्ञापक ह:ै धनात्मक प्रिाह ऋणात्मक प्रिाह विपरीत प्रिाह I यूवनटी हािं नहीं हािं min I यूवनटी हािं हािं नहीं tr सिाावधक इिंडवक्टि हािं हािं नहीं सिाावधक धाररतीय हािं हािं नहीं38 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] Itr से Imax की यूवनटी हािं नहीं नहीं सीमा के भीतर सिाावधक इिंडवक्टि हािं नहीं नहीं कोई परीक्षण लबिंद ु चुना र्ा सकता ह।ै सिाावधक धाररतीय हािं नहीं नहीं I यूवनटी हािं हािं हािं max सिाावधक इिंडवक्टि हािं हािं नहीं सिाावधक धाररतीय हािं हािं नहीं
(1) सारणी 1 के अनुसार सिावा धक इिंडवक्टि अथिा धाररतीय।
(ii) स्ितः उष्मन - परीक्षण का उद्देश्य: यह सत्यावपत करने के वलए क्रक मीटर, सारणी 4 में विवनर्दाष्ट अनुसार, Imax धारा को वनरिंतर िहन करन े में सक्षम ह।ै परीक्षण विवध: परीक्षण वनम्नानुसार क्रकया र्ाएगा: िोल्टेर् पररपथों को पहले सिंदभा िोल्टेर् पर िगा क के मीटरों के वलए कम-से-कम 1 घिंटे तथा अन्य सभी िगों के मीटरों के वलए कम-से-कम 2 घिंटे तक ऊर्ीकृत क्रकया र्ाएगा। इसके पिात, मीटर को अन्यथा सिंदभा पररवस्थवतयों में रखते हुए, धारा पररपथों पर अवधकतम धारा लागू की र्ाएगी। मीटर को ऊर्ीकृत करन े के वलए प्रयुक्त केबल तािंबे की होगी, वर्सकी लिंबाई 1 मीटर होगी तथा उसका अनुप्रस्थ काट ऐसा होगा क्रक धारा घनत्ि 3.2 A/mm² से 4 A/mm² के बीच रह।े मीटर की त्रुरट की वनगरानी एकात्मक शवक्त गुणािंक पर तथा इतने कम अिंतरालों पर की र्ाएगी क्रक समय के फलन के रूप में त्रुरट पररितान का िि अवभवलवखत क्रकया र्ा सके। परीक्षण कम-से-कम 1 घिंटे तक क्रकया र्ाएगा तथा क्रकसी भी वस्थवत में तब तक र्ारी रखा र्ाएगा र्ब तक क्रक क्रकसी भी 20 वमनट की अिवध के दौरान त्रुरट में पररितान, आधार अवधकतम स्िीकाया त्रुरट के 10% से अवधक न हो। अिंतर्नावहत त्रुरट की तुलना में त्रुरट में होने िाला पररितान, प्रत्येक समय पर सारणी 4 में वनर्दाष्ट आिश्यकताओं के अनुरूप होना चावहए। यक्रद परीक्षण की समावप्त तक त्रुरट पररितान वस्थर नहीं हुआ है (अथाात क्रकसी भी 20 वमनट की अिवध के दौरान त्रुरट में विचरण, आधार अवधकतम स्िीकाया त्रुरट के 10% से अवधक नहीं रह गया हो), तो या तो मीटर को उसके प्रारव्भक तापमान पर िापस आन े क्रदया र्ाएगा और सपिं ूणा परीक्षण को शवक्त गुणािंक = 0.5 इिंडवक्टि पर पुनः दोहराया र्ाएगा, अथिा यक्रद भार को 30 सेकिंड से कम समय में पररिर्तात क्रकया र्ा सकता हो, तो मीटर की त्रुरट का मापन Imax तथा शवक्त गुणािंक = 0.5 इिंडवक्टि पर क्रकया र्ाएगा और यह सत्यावपत क्रकया र्ाएगा क्रक अिंतर्नवा हत त्रुरट की तुलना म ें त्रुरट पररितान, सारणी 4 में क्रदए गए आिश्यकताओं के अनुरूप ह।ै[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 39
(iii) प्रारिंवभक धारा- परीक्षण का उद्देश्य: यह सत्यावपत करना क्रक मीटर सारणी 1 में वनर्दाष्ट Ist पर प्रार्भ होता ह ै तथा वनरिंतर काय ा करता रहता ह।ै परीक्षण विवध: मीटर पर प्रारिंवभक धारा के बराबर धारा लागू की र्ाएगी। यक्रद मीटर को वद्वक्रदशीय में ऊर्ाा के मापन के वलए अवभकवल्पत क्रकया गया ह,ै तो यह परीक्षण ऊर्ाा प्रिाह की प्रत्येक क्रदशा में क्रकया र्ाएगा। परीक्षण करते समय, ऊर्ाा प्रिाह की क्रदशा उलटने के बाद मापन में र्ानबूझकर क्रकए गए विलिंब के प्रभाि को ध्यान में रखा र्ाना चावहए। यक्रद मीटर का वनगाम सारणी 2 में वनर्दाष्ट आधार अवधकतम स्िीकाया त्रुरट की आिश्यकताओं के अनुरूप दर से क्षवणक विद्युत स्पिंदन अथिा पररिमण उत्पन्न करता ह,ै तो मीटर को प्रार्भ हो गया माना र्ाएगा। दो क्षवणक विद्युत स्पिंदनो के बीच अपेवक्षत समय, τ (आिताकाल), वनम्नवलवखत सूत्र द्वारा क्रदया र्ाता ह:ै
3.6X106 सेकिंड m.k.U .I nom st र्हाँ: k = मीटर के वनगाम उपस्करद्वारा प्रवत क्रकलोिाट-घिंटा (kWh) उत्सर्र्ात क्षवणक विद्युत स्पिंदनो की सिंख्या (imp/kWh) अथिा प्रवत क्रकलोिाट-घिंटा (kWh) घूणानों की सिंख्या (rev/kWh)। m = मीटर में प्रयुक्त तत्त्िों की सिंख्या। नाममात्र िोल्टेर् Unom को िोल्ट में तथा प्रारिंवभक धारा Ist को एव्पयर में व्यक्त क्रकया र्ाता ह।ै परीक्षण प्रक्रिया के चरण:
1. मीटर को प्रार्भ करें।
2. प्रथम क्षवणक विद्युत स्पिंदन के उत्पन्न होने के वलए 1.5 τ सेकिंड तक प्रतीक्षा करें।
3. वद्वतीय क्षवणक विद्यतु स्पिंदन के उत्पन्न होन े के वलए पुनः 1.5 τ सके िंड तक प्रतीक्षा करें।40 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)]
4. प्रथम और वद्वतीय क्षवणक विद्युत स्पिंदन के बीच के िास्तविक समय का वनधाारण करें।
5. वद्वतीय पल्स के बाद, ततृ ीय क्षवणक विद्युत स्पिंदन के उत्पन्न होने के वलए चरण 4 में वनधााररत िास्तविक समय के बराबर अिवध तक प्रतीक्षा करें। आज्ञापक परीक्षण लबिंद ु Ist पर एकात्मक शवक्त गुणािंक
(iv) वनभाार अिस्था का परीक्षण परीक्षण का उद्देश्य: 3(3)(iv) में वनर्दाष्ट मीटर के वनभारा अिस्था प्रदशान का विवधमान्यकरण करना। परीक्षण विवध: इस परीक्षण के वलए, ितामान सर्काट में कोई धारा नहीं होनी चावहए। परीक्षण Unom पर क्रकया र्ाएगा। परीक्षण वनगाम िाले मीटरों के वलए, मीटर का वनगाम एक से अवधक क्षवणक विद्यतु स्पदिं न उत्पन्न नहीं करेगा। विद्यतु -यािंवत्रक मीटर के वलए, मीटर का रोटर एक पूणा चक्कर नहीं लगाएगा। न्यूनतम परीक्षण अिवध ∆ होगी ∆t≥ 100X103 h, b.k.m.U .I nom min र्हाँ:
• b Imin पर आधार अवधकतम स्िीकाया त्रुरट वर्स े प्रवतशत (%) में व्यक्त क्रकया र्ाता ह ै तथा इसे धनात्मक मान के रूप में वलया र्ाता ह;ै • k मीटर के वनगाम उपस्करद्वारा प्रवत क्रकलोिाट-घिंटा उत्सर्र्ात क्षवणक विद्यतु स्पिंदनो की सिंख्या (imp/kWh) अथिा प्रवत क्रकलोिाट-घिंटा घूणानों की सिंख्या (rev/kWh);
• m मीटर में प्रयुक्त तत्त्िों की सिंख्या। नाममात्र िोल्टेर् Unom को िोल्ट V में व्यक्त क्रकया र्ाता ह;ै तथा न्यूनतम धारा (Imin) को एव्पयर A में व्यक्त क्रकया र्ाता ह।ै[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 41 प्राथवमक-रेटेड रवर्स्टर िाले ट्ािंसफॉमार-सिंचावलत मीटरों के वलए, र्हा ँ k (और सभिं ितः Unom) का मान प्राथवमक पक्ष के मानों के रूप में क्रदया गया हो, िहाँ k (और Unom) वस्थरािंक का पुनगाणना इस प्रकार की र्ाएगी क्रक िह वद्वतीयक पक्ष के िोल्टेर् और धारा मानों के अनरूु प हो। रटप्पण: उदाहरणाथा, िगा B के एक मीटर के वलए, वर्सका b = 1.5% ह ै तथा वर्सकी वनम्नवलवखत विवशष्टताएँ ह ैं k = 1000 imp/kWh, m = 1, Unom = 240 V तथा Imin = 0.6 A, न्यूनतम परीक्षण अिवध 0.46 घिंटे (27.8 वमनट) होगी।
(v) मीटर वस्थरािंक - परीक्षण का उद्देश्य यह सत्यावपत करन े के वलए क्रक आधरभतू ऊर्ाा रवर्स्टर (basic energy register) और प्रयुक्त परीक्षण वनगाम के बीच का सिंबिंध, उपबिंध 3(7)(ii) के अनुसार वनमााता द्वारा वनर्दाष्ट विवनदेशों के अनरूु प ह।ै सापेक्ष अिंतर, आधार अवधकतम स्िीकाया त्रुरट के दसिें भाग (1/10) स े अवधक नहीं होना चावहए। यह परीक्षण केिल उन वस्थवतयों में लागू होता ह,ै र्हा ँशुद्ता सिंबिंधी आिश्यकताओं के परीक्षण हते ु परीक्षण (क्षवणक विद्युत स्पिंदन) आउटपुट का उपयोग क्रकया र्ाता ह।ै परीक्षण विवध: विवधक वनयिंत्रण के अधीन आने िाले सभी रवर्स्टरों तथा क्षवणक विद्यतु स्पिंदन आउटपुटों का परीक्षण क्रकया र्ाना चावहए, र्ब तक क्रक ऐसी व्यिस्था विद्यमान न हो र्ो सभी मीटर वस्थरािंको के समान व्यिहार की गारिंटी प्रदान करती हो। यह परीक्षण मीटर के माध्यम से ऊर्ाा की एक मात्रा E प्रिावहत करके क्रकया र्ाएगा, र्हाँ E का मान कम-स-े कम वनम्नवलवखत होगा:
E = 1000.R Wh, min b र्हाँ:
R = आधरभूत ऊर्ाा रवर्स्टर का आभासी विभेदन, वर्स े िाट-घिंटा में व्यक्त क्रकया र्ाता ह;ै तथा b = आधार अवधकतम स्िीकाया त्रुरट वर्स े प्रवतशत (%) में व्यक्त क्रकया र्ाता ह।ै परीक्षण वनगाम से प्राप्त क्षवणक विद्युत स्पिंदनो की सख्िं या द्वारा वनधारा रत मीटर से प्रिावहत ऊर्ाा तथा रवर्स्टर में अवभवलवखत ऊर्ाा के बीच सापेक्ष अिंतर की गणना की र्ाएगी। अनुज्ञात प्रभाि: सापेक्ष अिंतर आधार अवधकतम स्िीकाया त्रुरट के दसिें भाग (1/10) स े अवधक नहीं होना चावहए।42 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] आज्ञापक परीक्षण लबिंद:ु यह परीक्षण क्रकसी एक स्िेवछछक धारा मान (arbitrary current) पर क्रकया र्ाएगा, I ≥Itr हो। रटप्पण (1): आधरभूत रवर्स्टर आभासी विभेदन R को बढाने के वलए क्रकसी भी साधन का उपयोग क्रकया र्ा सकता है, यक्रद यह सुवनवित करन ेके वलए उवचत सािधानी बरती र्ाए क्रक प्राप्त पररणाम आधरभूत रवर्स्टर के िास्तविक विभेदन को सही रूप में प्रवतलबिंवबत करते हों। रटप्पण (2): b का मान चयवनत परीक्षण लबिंद ु (test point) के अनसु ार सारणी 2 से वलया र्ाएगा। b का मान, वनभारा परीक्षण के वलए लागू मान स े वभन्न हो सकता ह।ै
(3) प्रभािकारी मात्राओं के वलए परीक्षण
(i) सामान्य– इन परीक्षणों का उद्देश्य 3(3)(iii) की आिश्यकताओं को सत्यावपत करना है, र्ो क्रकसी एकल प्रभािकारी मात्रा के पररितना के कारण उत्पन्न होती ह।ैं सारणी 4 में सूचीबद् प्रभािकारी मात्राओं के वलए यह सत्यावपत क्रकया र्ाएगा क्रक क्रकसी भी एकल प्रभािकारी मात्रा के पररितान के कारण होने िाला त्रुरट पररितान, सारणी 4 में क्रदए गए सिंबिंवधत त्रुरट पररितान की सीमा के भीतर ह ै देख)ें 2(2)(xx) में पररभावषत अवधकतम स्िीकाया त्रुरट पररितान।
(ii) तापमान पर वनभारता – परीक्षण का उद्देश्य: यह पुवष्ट करने के वलए क्रक सारणी 3 की तापमान गुणािंक सिंबिंधी आिश्यकताएँ पूरी होती ह।ैं परीक्षण विवध: प्रत्येक परीक्षण लबिंद ु के वलए, मीटर की त्रुरट का वनधाारण सिंदभा तापमान पर, मीटर के वलए विवनर्दाष्ट ऊपरी और वनचली पररिेश तापमान सीमाओं में से प्रत्येक पर, तथा पयााप्त सिंख्या में अन्य तापमानों पर क्रकया र्ाएगा, र्ो 15 K से 23 K के बीच के तापमान अिंतराल बनाते हुए विवनर्दाष्ट तापमान सीमा को आछछाक्रदत करते ह।ैं इसके अवतररक्त, प्रत्येक परीक्षण लबिंद ु तथा प्रत्येक तापमान अिंतराल के वलए, र्ो सिंदभ ा तापमान सवहत वनकटिती ऊपरी या वनचली तापमान सीमाओं द्वारा क्रदया गया है, (औसत) तापमान गुणािंक, c, वनम्नवलवखत प्रकार से वनधााररत क्रकया र्ाएगा:
c = e-e u l t-t u l र्हाँ eu और el िमशः रुवच के तापमान अिंतराल में उच्चतम और वनम्नतम तापमान पर त्रुरटयािं ह;ैं और[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 43 रुवच के तापमान अतिं राल में tu और tl िमशः अवधकतम और न्यूनतम तापमान ह।ैं प्रत्येक तापमान गुणािंक सारणी 3 की अपेक्षाओं के अनुरूप होना चावहए। अवनिाया परीक्षण लबिंद:ु परीक्षण को कम स े कम PF = 1 और PF = 0.5 इिंडवक्टि पर, और Itr, 10 Itr और Imax करिंट के वलए वनष्पाक्रदत क्रकया र्ाएगा। रटप्पणी: सिंयुक्त अवधकतम त्रुरट की गणना के वलए, र्ैसा क्रक उपा A [A(2)(i) या A(2)(ii)] में पररभावषत ह,ै यह अपेवक्षत हो सकता ह ै क्रक कुछ अवतररक्त परीक्षण लबिंद ु (additional test points) शावमल क्रकए र्ाएँ, ताक्रक कम-स-े कम Imin स े Imax की धारा सीमा पर तथा कम-स-े कम 0.5 प्रेरणात्मक से 0.8 धाररतात्मक तक के शवक्त गुणािंक की सीमा को किर क्रकया र्ा सके।
(iii) भार सिंतुलन – परीक्षण का उद्देश्य: यह सत्यावपत करने के वलए क्रक भार सतिं ुलन के कारण होने िाला त्रुरट पररितान, सारणी 4 की अपेक्षाओं के अनुरूप ह।ै यह परीक्षण केिल बहु-फेज़ मीटरों तथा एकल-फेज़ तीन-तार मीटरों के वलए लागू ह।ै परीक्षण विवध: केिल एक करिंट सर्काट में करिंट होने पर मीटर की त्रुरट मापी र्ाएगी और सिंतुवलत लोड पर उसकी आिंतररक त्रुरट से तुलना की र्ाएगी। परीक्षण के दौरान, सभी िोल्टेर् सर्काट पर सिंदभा िोल्टेर् लागू क्रकए र्ाएिंगे। अवनिाया परीक्षण लबिंद:ु परीक्षण सभी धारा पररपथों के वलए शवक्त गुणािंक (PF) = 1 तथा PF = 0.5 प्रेरणात्मक पर क्रकया र्ाएगा, तथा न्यूनतम रूप से प्रत्यक्ष-सिंचावलत मीटरों (direct meters) के वलए 10 Itr और Imax पर, और ट्ािंसफॉमार-सिंचावलत मीटरों के वलए न्यूनतम Imax पर क्रकया र्ाएगा। रटप्पण: उपाबिंद क [A(2)(ii)] में पररभावषत सिंयुक्त अवधकतम त्रुरट की गणना के वलए, Imin स े Imax तक की करिंट रेंर् में, 0.5 इिंडवक्टि से 0.8 कैपेवसरटि तक के पािर फैक्टर रेंर् को किर करने के वलए कुछ अवतररक्त परीक्षण लबदिं ु लागू करने की अपेक्षा हो सकती ह।ै
(iv) िोल्टेर् उतार-चढाि,– परीक्षण का उद्देश्य: यह सत्यावपत करने के वलए क्रक िोल्टेर् वभन्नता के कारण त्रुरट बदलाि सारणी 4 की अपेक्षाओं का अनुपालन करता ह।ै परीक्षण विवध: िोल्टेर् को सिंबिंवधत रेटेड ऑपरेटटिंग रेंर् में बदलने पर, Unom पर मौर्ूद त्रुरट की तुलना में त्रुरट वशफ्ट को मापा र्ाना चावहए। पॉली-फेर् मीटर के वलए, टेस्ट िोल्टेर् सिंतुवलत होना44 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] चावहए। यक्रद कई Unom मान वनर्दाष्ट ह,ैं तो परीक्षण को प्रत्येक Unom मान के वलए दोहराया र्ाएगा। अवनिाया परीक्षण लबिंद:ु 10 I करिंट और 0.9 Unom तथा 1.1 Unom िोल्टेर् पर इिंडवक्टि। tr रटप्पण: उपाबिंद क [क(2)(i) या क(2)(ii)] में पररभावषत सिंयुक्त अवधकतम त्रुरट की गणना के वलए, Imin से Imax तक की करिंट रेंर् में, 0.5 इिंडवक्टि से 0.8 कैपेवसरटि तक के पािर फैक्टर रेंर् को किर करने हते ु कुछ अवतररक्त टेस्ट पॉइिंट लागू करने की अपेक्षा हो सकती ह।ै
(v) आिृवत्त में पररितान,– परीक्षण का उद्देश्य: यह सत्यावपत करने के वलए क्रक आिृवत्त वभन्नता के कारण त्रुरट बदलाि तावलका 4 की अपेक्षाओं का अनुपालन करता ह।ै परीक्षण विवध: आिृवत्त को सिंबिंवधत रेटेड ऑपरेटटिंग रेंर् के भीतर बदलन े पर, fnom पर अतिं र्नावहत त्रुरट की तुलना में त्रुरट बदलाि को मापा र्ाएगा। यक्रद कई fnom मान वनर्दाष्ट ह,ैं तो परीक्षण प्रत्येक fnom मान के वलए दोहराया र्ाएगा। अवनिाया परीक्षण लबिंद:ु परीक्षण न्यूनतम PF = 1 और PF = 0.5 इिंडवक्टि पर, 10 Itr करिंट के वलए, और 0.98 fnom तथा 1.02 fnom की फ्रीवेंसी पर क्रकया र्ाना चावहए। रटप्पण: उपाबिंद [क(क(2)(i) या क(2)(ii)] में बताई गई सिंयुक्त अवधकतम त्रुरट की गणना के वलए, कम से कम Imin से Imax की करिंट रेंर् में 0.5 इिंडवक्टि से 0.8 कैपेवसरटि तक की पािर फैक्टर रेंर् को किर करने के वलए कुछ अवतररक्त टेस्ट पॉइिंट लागू करने की अपेक्षा हो सकती है।
(vi) िोल्टेर् और धारा में हामोवनक्स,– परीक्षण का उद्देश्य: यह सुवनवित करने के वलए क्रक हामोवनक्स के कारण होन े िाला एरर वशफ्ट अपेक्षाओं को पूरा करता ह।ै परीक्षण विवध: र्ब िोल्टेर् और करिंट दोनों में हामोवनक्स र्ोड़े र्ाएिं, तो साइनसोइडल वस्थवतयों की अिंतर्नावहत त्रुरट के मुकाबले त्रुरट बदलाि को मापा र्ाएगा। यह परीक्षण सारणी 11 और सारणी 12 म ें क्रदए गए वाड्रीफॉमा और पीक्ड िेिफॉमा का उपयोग करके क्रकया र्ाना चावहए। क्रकसी एकल हामोवनक का आयाम िोल्टेर् के वलए 0.12 U1/h और धारा के वलए I1/h से अवधक नहीं होना चावहए, र्हाँ h हामोवनक सिंख्या ह ै और U1 तथा I1 िमशः मूल मान ह।ैं सारणी 11 और सारणी 12 में िेिफॉमा के वलए धारा आयाम के प्लॉट िमशः वचत्र 1 और वचत्र 2 म ेंक्रदखाए गए ह।ैं[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 45 आर.एम.एस.धारा Imax स े अवधक नहीं होनी चावहए, अथाात सारणी 11 के वलए, मूलभूत धारा घटक I1, 0.93 I स े अवधक नहीं होना चावहए। धारा का वशखर मान 1.4 अवधकतम I से अवधक नहीं होना चावहए, अथाात सारणी 12 के वलए, मूलभूत धारा घटक I1 अवधकतम (आर.एम.एस.), 0.568 I से अवधक नहीं होना चावहए। अवधकतम हामोवनक आयामों की गणना िमशः िोल्टेर् या करिंट के मूल आिृवत्त घटक के आयाम के सापेक्ष की र्ाती ह।ै चरण कोण की गणना िमशः मूल आिृवत्त िोल्टेर् या करिंट घटक के शून्य- िॉलसिंग के सापेक्ष की र्ाती ह।ै अवनिाया परीक्षण लबिंद:ु परीक्षण न्यूनतम 10 लीटर, PF = 1 पर क्रकया र्ाना चावहए, र्हाँ पािर फैक्टर मलू भूत घटक के वलए क्रदया गया ह।ै रटप्पण: उपाबिंद क [क(2)(ii)] में पररभावषत सिंयुक्त अवधकतम त्रुरट की गणना के वलए, Imin स े Imax तक की करिंट रेंर् में, 0.5 इिंडवक्टि से 0.8 कैपेवसरटि तक की पािर फैक्टर रेंर् को किर करने हते ु कुछ अवतररक्त परीक्षण लबिंद ुलागू करने की अपेक्षा हो सकती ह।ै रटप्पण 11 वाड्रीफॉमा िेिफॉमा हामोवनक सिंख्या विद्युत धारा का करिंट चरण कोण िोल्टेर् आयाम िोल्टेर् फेज़ कोण आयाम 1 100 % 0° 100 % 0° 3 30 % 0° 3.8 % 180° 5 18 % 0° 2.4 % 180° 7 14 % 0° 1.7 % 180° 11 9 % 0° 1.0 % 180°46 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] 13 5 % 0° 0.8 % 180° सारणी 12 पीक्ड िेिफॉमा हामोवनक सिंख्या विद्युत धारा का करिंट चरण िोल्टेर् आयाम िोल्टेर् फेज़ कोण आयाम कोण 1 100 % 0° 100 % 0° 3 30 % 180° 3.8 % 0° 5 18 % 0° 2.4 % 180° 7 14 % 180° 1.7 % 0° 11 9 % 180° 1.0 % 0° 13 5 % 0° 0.8 % 180°[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 47
(vii) झुकाि,– परीक्षण का उद्देश्य: यह सत्यावपत करने के वलए क्रक झुकाि के कारण त्रुरट बदलाि सारणी 4 की अपेक्षाओं का अनुपालन करता ह।ै यह परीक्षण केिल इलेक्ट्ोमैकेवनकल मीटर या अन्य वनमााणों के मीटरों के वलए ह ै र्ो कायाशील वस्थवत से प्रभावित हो सकते ह।ैं परीक्षण विवध:: विवनमााता द्वारा वनर्दाष्ट ऑपरेटटिंग वस्थवत पर मौर्ूद स्िाभाविक त्रुरट की तुलना में, मीटर को उसकी आदशा वस्थवत से 3° के कोण पर झुकाने पर होने िाले त्रुरट बदलाि को मापा र्ाएगा। अवनिाया परीक्षण: परीक्षण न्यूनतम रूप से Itr, PF = 1 पर और दो लिंबित झुकाि कोणों पर क्रकया र्ाएगा।
(viii) िोल्टेर् में भारी अवस्थरता,– परीक्षण का उद्देश्य: यह सत्यावपत करने के वलए क्रक िोल्टेर् में भारी उतार-चढाि के कारण त्रुरट बदलाि सारणी 4 की अपेक्षाओं का अनुपालन करता ह।ै परीक्षण विवध: 1: आिंतररक त्रुरट को सबसे पहले Unom पर मापा र्ाना चावहए। इसके बाद यह सत्यावपत क्रकया र्ाएगा क्रक र्ब िोल्टेर् को 0.8 Unom से 0.9 Unom और 1.1 Unom से 1.15 Unom तक बदला र्ाता ह,ै तो Unom पर आिंतररक त्रुरट के सापेक्ष त्रुरट का बदलाि सारणी 4 की अपेक्षाओं48 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] का अनुपालन करता ह।ै बहु-चरण मीटरों के वलए, परीक्षण िोल्टेर् सिंतुवलत होना चावहए। यक्रद कई Unom मान क्रदए गए ह,ैं तो प्रत्येक Unom मान के वलए परीक्षण दोहराया र्ाएगा। अवनिाया परीक्षण: यह परीक्षण कम से कम 10 लीटर, PF = 1 और 0.8 Unom, 0.85 Unom और 1.15 Unom िोल्टेर् लबिंदओंु के वलए क्रकया र्ाना चावहए। परीक्षण विवध: 2: इसके अवतररक्त, र्ब िोल्टेर् को 0.8 Unom से घटाकर 0 क्रकया र्ाता ह,ै तो Unom पर वनवहत त्रुरट की तुलना में त्रुरट बदलाि को मापा र्ाना चावहए। अवनिाया परीक्षण लबिंद:ु यह परीक्षण कम स े कम 10 ltr, PF = 1 पर और 0.7 Unom, 0.6 Unom, 0.5 Unom,
0.4 Unom, 0.3 Unom, 0.2 Unom, 0.1 Unom, तथा 0 V के िोल्टेर् के वलए क्रकया र्ाना चावहए। यक्रद मीटर में एक विवशष्ट शट-डाउन िोल्टेर् ह,ै तो अवनिाया परीक्षण लबिंदओंु में शट-डाउन िोल्टेर् से एक लबिंद ुऊपर और एक लबिंद ु नीचे का लबिंद ु शावमल होना चावहए। वनचला परीक्षण लबिंद ु शट-डाउन िोल्टेर् से 2 V की सीमा के भीतर होना चावहए। ऊपरी परीक्षण लबिंद ुटना-ऑन िोल्टेर् से 2 V की सीमा के भीतर होना चावहए।
(ix) एक या दो चरण बावधत हो गए,– परीक्षण का उद्देश्य: यह सत्यावपत करने के वलए क्रक एक या दो चरणों के बावधत होने के कारण त्रुरट बदलाि सारणी 4 की अपेक्षाओं का अनुपालन करता ह।ै यह परीक्षण केिल तीन मापन े िाले तत्िों िाले बहु- चरण मीटरों के वलए ह।ै परीक्षण विवध:: सिंतुवलत िोल्टेर् और लोड करिंट की वस्थवतयों में होने िाली स्िाभाविक त्रुरट की तुलना में, त्रुरट में बदलाि तब मापा र्ाएगा र्ब लोड करिंट को वस्थर रखते हुए एक या दो फेज़ हटा क्रदए र्ाएिं। दो फेज़ को हटाने की वस्थवत केिल उन कनेक्शन मोड के वलए ह ै र्हाँ एक फेज़ के न होने पर भी ऊर्ाा की आपूर्ता हो सकती ह।ै यक्रद कोई पॉली-फेज़ मीटर केिल अपने क्रकसी एक फेज़ स े चल रहा ह,ै तो इस टेस्ट के वलए उस फेज़ के िोल्टेर् में कोई रुकािट नहीं डाली र्ाएगी। अवनिाया परीक्षण लबिंद:ु परीक्षण न्यूनतम 10 लीटर पर क्रकया र्ाना चावहए, वर्समें एक या दो चरणों को इस तरह के सिंयोर्नों में हटाया र्ाए क्रक प्रत्येक चरण कम से कम एक बार हटाया गया हो।[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 49
(x) एसी धारा पररपथ में उप-हामोवनक्स,– परीक्षण का उद्देश्य: यह सत्यावपत करने के वलए क्रक सब-हामोवनक्स के कारण त्रुरट बदलाि सारणी 4 की अपेक्षाओं का अनुपालन करता ह।ै परीक्षण विवध:: साइनसॉइडल वस्थवतयों में वनवहत त्रुरट की तुलना में त्रुरट वशफ्ट को तब मापा र्ाना चावहए र्ब साइनसॉइडल सिंदभा करिंट को दोगुनी पीक िैल्यू िाल ेदसू रे साइनसॉइडल वसग्नल से बदला र्ाता ह,ै और वर्से वचत्र 3 a) और b) के अनुसार हर दसू रे पीररयड में चालू और बिंद क्रकया र्ाता ह।ै (मापी गई शवक्त तब मूल साइनसॉइडल वसग्नल के समान होनी चावहए र्बक्रक आर.एम.एस.
करिंट 1.41 गुना अवधक हो)। यह सुवनवित करें क्रक कोई महत्िपूणा DC करिंट न आए। परीक्षण के दौरान, करिंट का पीक मान 1.4 Imax से अवधक नहीं होना चावहए। अवनिाया परीक्षण लबिंद:ु परीक्षण न्यूनतम 10 Itr के सदिं भा करिंट और PF = 1 पर क्रकया र्ाना चावहए।
(xi) प्रत्यािती धारा पररपथ में हामोवनक्स,– परीक्षण का उद्देश्य: यह सत्यावपत करन े के वलए क्रक एसी करिंट सर्काट में हामोवनक्स के कारण त्रुरट बदलाि सारणी 4 की अपेक्षाओं का अनुपालन करता ह।ै50 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] परीक्षण विवध:: साइनसोइडल वस्थवतयों में अतिं र्नावहत त्रुरट की तुलना में, त्रुरट बदलाि को तब मापा र्ाएगा र्ब वचत्र 3 क) में क्रदखाए गए साइनसोइडल सिंदभा करिंट को मलू वशखर मान से दोगुन े करिंट से बदल क्रदया र्ाता ह,ै र्हाँ साइनसोइडल तरिंगरूप को अिवध के पहले और तीसरे वाटार के दौरान शून्य पर सेट क्रकया र्ाता ह,ै र्ैसा क्रक वचत्र 3 ग) में क्रदखाया गया ह।ै मापी गई शवक्त मूल साइनुसोइडल वसग्नल के समान होनी चावहए, र्बक्रक आर.एम.एस. करिंट 1.41 गुना अवधक होगी। परीक्षण के दौरान, धारा का वशखर मान 1.4 Imax से अवधक नहीं होना चावहए। अवनिाया परीक्षण लबिंद:ु परीक्षण न्यूनतम 10 Itr के सिंदभा करिंट और PF = 1 पर क्रकया र्ाएगा। वनदेशक (विवधक मापविज्ञान) द्वारा अवतररक्त परीक्षण लबिंद ुवनर्दाष्ट क्रकए र्ा सकत े ह।ैं
(xii) विपरीत चरण अनुिम (क्रकन्हीं दो चरणों को आपस में बदलना)– परीक्षण का उद्देश्य: यह सत्यावपत करने के वलए क्रक क्रकन्हीं दो फेज़ों को आपस में बदलने के कारण होन े िाला त्रुरट विस्थापन सारणी 4 की अपेक्षाओं का अनुपालन करता ह।ै यह परीक्षण केिल तीन-फेज़ मीटरों पर लागू होता ह।ै परीक्षण विवध: र्ब तीन चरणों म ेंस ेक्रकन्हीं दो चरणों को बदला र्ाता ह,ै तब सिंदभा वस्थवतयों की आिंतररक त्रुरट की तुलना में त्रुरट बदलाि को मापा र्ाना चावहए। अवनिाया परीक्षण लबिंद:ु परीक्षण न्यूनतम 10 Itr के सिंदभा करिंट और PF = 1 पर क्रकया र्ाएगा, वर्समें तीन में से क्रकन्हीं दो फेज़ को आपस में बदला र्ाएगा। र्ाएगा। वनदेशक (विवधक मापविज्ञान) द्वारा अवतररक्त परीक्षण लबिंद ुवनर्दाष्ट क्रकए र्ा सकत े ह।ैं
(xiii) बाहरी स्रोत का वनरिंतर (डीसी) चुिंबकीय प्रेरण – परीक्षण का उद्देश्य: यह सत्यावपत करने के वलए क्रक बाहरी मूल के वनरिंतर (डीसी) चुिंबकीय प्रेरण के कारण त्रुरट बदलाि सारणी 4 की अपेक्षाओं का अनुपालन करता ह।ै परीक्षण विवध:: सिंदभा वस्थवतयों में अिंतर्नावहत त्रुरट की तुलना में त्रुरट बदलाि को तब मापा र्ाना चावहए र्ब मीटर पर 2000 mm² से अवधक सतह क्षेत्र िाले स्थायी चबुिं क प्रोब द्वारा वनरिंतर चुिंबकीय प्रेरण लागू क्रकया र्ाए। चुिंबक के कोर की धरु ी के साथ चुिंबकीय क्षेत्र तावलका 13 (1) के वििरण के अनुरूप होना चावहए। रटप्पणी (1): आिश्यकतानुसार कम चुिंबकीय प्रेरण चुना र्ा सकता ह।ै[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 51 सारणी 13 चुिंबक के कोर की धुरी के साथ क्षेत्र के विवनदेश चुिंबक की सतह से दरू ी चुिंबकीय प्रेरण सहनशीलता 30 mm 200 Mt ± 30 mT अवनिाया परीक्षण लबिंद:ु 6 पॉइिंट्स प्रवत मीटर सतह। परीक्षण को न्यूनतम 10 लीटर, PF = 1 पर वनष्पाक्रदत क्रकया र्ाना चावहए। अवधकतम त्रुरट विचलन को परीक्षण पररणाम के रूप में दर्ा क्रकया र्ाना चावहए। रटप्पण : इस परीक्षण के वलए वनयोवडवमयम या वनयोवबयम परमानेंट मैग्नेट का उपयोग क्रकया र्ा सकता ह।ै
(xiv) बाहरी मूल का चुिंबकीय क्षेत्र (एसी, पािर फ़्रीवेंसी) – परीक्षण का उद्देश्य: यह सत्यावपत करन े के वलए क्रक पािर फ़्रीवेंसी पर एसी चबुिं कीय क्षेत्र के कारण त्रुरट बदलाि सारणी 4 की अपेक्षाओं का अनुपालन करता ह।ै परीक्षण विवध:: पािर फ़्रीवेंसी (f = fnom) पर, फेज़ और क्रदशा की सबस े प्रवतकूल वस्थवत में चुिंबकीय क्षेत्र के प्रभाि में, सिंदभा वस्थवतयों की आिंतररक त्रुरट की तुलना में मीटर के त्रुरट बदलाि को मापा र्ाना चावहए। परीक्षण की गिंभीरता: सतत क्षेत्र, 400 A/m.
अवनिाया परीक्षण लबिंद:ु परीक्षण न्यूनतम 10 Itr और Imax पर, PF = 1 के साथ क्रकया र्ाना चावहए।
(xv) विद्युत चु्बकीय क्षेत्र,- (क) रेवडएशन, रेवडयो फ़्रीवेंसी (आरएफ), इलेक्ट्ोमैग्नेरटक फील््स,– परीक्षण का उद्देश्य: यह सत्यावपत करन े के वलए क्रक रेवडएटेड रेवडयो फ़्रीवेंसी इलेक्ट्ोमैग्नेरटक फील्ड के कारण होने िाला एरर वशफ्ट सारणी 4 की अपेक्षाओं का अनुपालन करता ह।ै इलेक्ट्ोमैकेवनकल मीटर र्ैसे मीटर, र्ो केिल पैवसि तत्िों का उपयोग करके बनाए गए हैं, उन्ह ें रेवडएटेड रेवडयो फ़्रीवेंसी फील्ड के प्रवत प्रवतरवक्षत माना र्ाएगा। रटप्पण, नीचे दी गई परीक्षण वस्थवत 2, 6.4.6 के वडस्टबेंस टेस्ट के अनुरूप ह।ै52 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] परीक्षण विवध: साइनसोइडल वस्थवतयों म ें आिंतररक त्रुरट की तुलना में, त्रुरट वशफ्ट के वलए विद्यतु चु्बकीय क्षेत्र की तीव्रता गिंभीरता स्तर द्वारा वनर्दाष्ट की र्ाएगी और क्षेत्र की एकरूपता सिंदर्भात मानक द्वारा पररभावषत की र्ाएगी। विचार की र्ाने िाली आिवृ त्त श्रेवणयों को मॉड्यूलेटेड वसग्नल के साथ स्िीप क्रकया र्ाता ह,ै और आरएफ वसग्नल स्तर को समायोवर्त करने या आिश्यकतानसु ार ऑवसलेटर और एिंटेना को वस्िच करने के वलए ठहराि वलया र्ाता ह।ै र्हाँ आिृवत्त सीमा (फ़्रीवेंसी रेंर्) को िवमक रूप से बदला र्ाता ह,ै िहा ँचरण आकार (स्टेप साइज़) वपछली आिृवत्त मान के 1% से अवधक नहीं होना चावहए। 1% आिृवत्त पररितान के वलए परीक्षण का समय, माप लेने में लगने िाले समय से कम नहीं होना चावहए और क्रकसी भी मामले में 0.5 सेकिंड स े कम नहीं होना चावहए। इलेक्ट्ोमैग्नेरटक फील्ड के सिंपका में आने िाली केबल की लबिं ाई 1 मीटर होगी। परीक्षण र्नरेटटिंग एिंटीना को मीटर के प्रत्येक पक्ष की ओर करके क्रकया र्ाएगा। र्ब मीटर का उपयोग विवभन्न ओररएिंटेशन (अथाात् िर्टाकल या हॉररर्ॉन्टल) में क्रकया र्ा सकता ह,ै तो परीक्षण के दौरान सभी पक्षों को फील्ड के सिंपका में लाया र्ाएगा। िाहक को 1 kHz साइन िेि पर 80% AM के साथ मॉड्यूलेट क्रकया र्ाएगा। मीटर का परीक्षण वनमाता ा द्वारा वनर्दाष्ट क्लॉक आिृवत्तयों पर अलग से क्रकया र्ाएगा। क्रकसी भी अन्य सिंिेदनशील आिृवत्तयों का भी अलग से विश्लेषण क्रकया र्ाएगा। रटप्पण : आमतौर पर इन सििं ेदी तीव्रता के मीटर स े वनकलने िाली आिृवत्त होने की आशा की र्ा सकती ह।ै मीटर को दो परीक्षण शत ामें टेबल-टॉप इिंस्ूमेंट के तौर पर परीक्षण क्रकया र्ाएगा, र्हाँ परीक्षण शता 2, 6(4)(vi) के वडस्टबेंस परीक्षण से मेल खाती ह।ै परीक्षण शता 1: परीक्षण के दौरान, मीटर को सिंदभा िोल्टेर् और 10 Itr के बराबर करिंट से सक्रिय क्रकया र्ाएगा। मीटर की माप त्रुरट की वनगरानी एक ऐसे सिंदभा मीटर से तुलना करके की र्ाएगी र्ो विद्यतु चु्बकीय क्षेत्र के सिंपका में न हो या क्षेत्र के प्रवत प्रवतरवक्षत हो, या क्रकसी समान उपयक्तु विवध द्वारा की र्ाएगी। िाहक आिृवत्त के प्रत्येक 1% िृवद्शील अिंतराल पर त्रुरट की वनगरानी की र्ाएगी और सारणी 4 की अपेक्षाओं से तुलना की र्ाएगी। लगातार तीव्रता स्िीप का उपयोग करते समय, इसे स्िीप के समय और हर माप के समय के अनुपात को एडर्स्ट करके क्रकया र्ा सकता ह।ै 1% के इिंिीमेंटल तीव्रता स्टेप्स का उपयोग करते समय, इसे हर तीव्रता पर '्िेल टाइम' को माप के समय के वहसाब से समायोवर्त करके क्रकया र्ा सकता ह।ै[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 53 परीक्षण शता 2: परीक्षण के दौरान, मीटर के िोल्टेर् और सहायक सर्काट को सिंदभा िोल्टेर् स े सक्रिय क्रकया र्ाना चावहए। करिंट सर्काट में कोई करिंट नहीं होना चावहए और करिंट टर्मानल खुले होने चावहए। रटप्पण : परीक्षण वस्थवत 2, 6(4)(vi) के व्यिधान परीक्षण के अनुरूप ह,ै अतः 6(4)(i) के सामान्य वनदेश भी लाग ू होते ह।ैं परीक्षण की गिंभीरता: सारणी 14 के अनसु ार। सारणी 14 परीक्षण की गिंभीरता परीक्षण की वस्थवत के वलए आिृवत सीमा क्षेत्र सामर्थय ा परीक्षण वस्थवत 1 (करिंट के 80 – 6000 MHz 10 V/m साथ) परीक्षण वस्थवत 2 (करिंट के 80 – 6000 MHz 30 V/m वबना) (ख) रेवडयो आिृवत्त क्षेत्रों के कारण होने िाले किंडक्टेड वडस्टबेंस के प्रवत प्रवतरोधक क्षमता,- परीक्षण का उद्देश्य: यह सत्यावपत करने के वलए क्रक RF क्षेत्रों द्वारा प्रेररत सिंचावलत गड़बड़ी के कारण त्रुरट बदलाि सारणी 4 की अपेक्षाओं का अनुपालन करता ह।ै इलेक्ट्ोमैकेवनकल मीटर र्सै े मीटर र्ो केिल वनवष्िय तत्िों का उपयोग करके बनाए गए हैं, उन्ह ेंआर एफ क्षेत्रों द्वारा प्रेररत सिंचावलत गड़बड़ी से प्रवतरवक्षत माना र्ाएगा। परीक्षण विवध: मानक में पररभावषत कपललिंग/डीकपललिंग उपकरणों का उपयोग करके, इलेक्ट्ोमैग्नेरटक फील्ड के प्रभाि का अनुकरण करने के वलए मीटर के पािर पोटा और आई/ओ पोटा में एक रेवडयो आिृवत्त इलेक्ट्ोमैग्नेरटक करिंट को र्ोड़ा या इिंर्ेक्ट क्रकया र्ाएगा। आरएफ र्नरेटर, (डी)कपललिंग उपकरणों, एटेन्यूएटर आक्रद से युक्त परीक्षण उपस्करके प्रदशान को सत्यावपत क्रकया र्ाएगा। मीटर का परीक्षण एक टेबल-टॉप उपस्करके रूप में क्रकया र्ाएगा। परीक्षण के दौरान, मीटर को सिंदभा िोल्टेर् और 10 Itr के बराबर करिंट स े सक्रिय क्रकया र्ाएगा। कैररयर आिृवत्त के प्रत्येक 1% िृवद्शील अिंतराल पर त्रुरट की वनगरानी की र्ाएगी और सारणी 4 की अपेक्षाओं से तुलना की र्ाएगी। वनरिंतर फ़्रीवेंसी स्िीप का उपयोग करत े समय, इस े स्िीप समय और प्रत्यके माप के समय के अनुपात को समायोवर्त करके प्राप्त क्रकया र्ा सकता ह।ै 1% के िृवद्शील आिृवत्त54 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] चरणों का उपयोग करत े समय, इसे माप समय के अनरूु प प्रत्येक फ़्रीवेंसी पर ठहरन े के समय को समायोवर्त करके प्राप्त क्रकया र्ा सकता ह।ै यक्रद मीटर पॉली-फेज़ ह,ै तो परीक्षण केबल के सभी वसरों पर क्रकया र्ाना चावहए। परीक्षण की गिंभीरता: आरएफ ए्प्लीट्यूड (50 Ohm): 10 V (e.m.f.) आिृवत सीमा: 0.15 – 80 MHz मॉड्यूलेशन: 80 % AM, 1 kHz sine wave
(xvi) एसी पररपथ में डीसी- परीक्षण का उद्देश्य: यह सत्यावपत करन े के वलए क्रक एसी करिंट सर्काट में डीसी के कारण होन े िाला एरर वशफ्ट सारणी 4 की अपेक्षाओं का अनुपालन करता ह।ै इलेक्ट्ोमैकेवनकल और ट्ािंसफॉमार सिंचावलत मीटरों को एसी करिंट सर्काट में डीसी से अप्रभावित माना र्ाएगा। परीक्षण विवध: र्ब करिंट ए्प्लीट्यूड को दोगुना (I = Imax) क्रकया र्ाता ह ै और उसे हाफ-िेि रेवक्टफाइड क्रकया र्ाता ह,ै तब I = Imax/2 पर साइनसोइडल वस्थवतयों की स्िाभाविक त्रुरट तुलना म ें त्रुरट वशफ्ट को मापा र्ाएगा। अवनिाया परीक्षण: परीक्षण PF = 1 पर क्रकया र्ाना चावहए। रटप्पण 1: हाफ-िेि रेवक्टक्रफकेशन और मापन वचत्र 4 के अनुसार क्रकया र्ा सकता ह ै (केिल करिंट पथ क्रदखाया गया है, िोल्टेर् सामान्य रूप से र्ोड़ा र्ाएगा)। इस विवध में मापन की अवनवितता, करिंट सोसा के (सब-पीररयड) आउटपुट इ्पीडेंस और मानक मीटर के करिंट सर्काट इ्पीडेंस के साथ-साथ दोनों करिंट शाखाओं के सिंभावित इ्पीडेंस अतिं र पर बहुत अवधक वनभार करती ह।ै रटप्पण 2: चूँक्रक अवनवितता पूणा शाखा प्रवतबाधा अिंतर पर वनभार करती है, न क्रक सापेक्ष अिंतर पर (यक्रद आरबैलैंलसिंग >>आरसोसा हो), अतः आमतौर पर प्रत्येक शाखा में अवतररक्त सुमेवलत प्रवतरोधक लगाकर इस समस्या का समाधान नहीं क्रकया र्ा सकता ह।ै तथावप, स्रोत स े डीसी करिंट का अध्ययन करके इसकी वनगरानी की र्ा सकती ह।ै डीसी घटकों को एसी मान के 0.5 से 1% स ेअवधक नहीं होना चावहए। (एसी घटक के 1% के िम में डीसी घटक को मापते समय, उपस्कर को पहले टेस्ट सर्काट डायोड को वडस्कनेक्ट और शॉटा-सर्काट करके परीक्षण करिंट के माप द्वारा अिंशािंकन क्रकया र्ाना चावहए।)[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 55
(xvii) उच्च-स्तरीय हामोवनक्स- परीक्षण का उद्देश्य: यह सत्यावपत करने के वलए क्रक उच्च-िम हामोवनक्स के कारण त्रुरट बदलाि सारणी 4 की अपेक्षाओं का अनुपालन करता ह।ै इसके अवतररक्त , मीटर के काया में बाधा नहीं आनी चावहए। परीक्षण विवध: साइनसोइडल वस्थवतयों में होने िाली स्िाभाविक त्रुरट की तुलना में त्रुरट में बदलाि को तब मापा र्ाएगा, र्ब f = 15 fnom से 40 fnom तक बदले र्ाने िाले एलसिंिोनस टेस्ट वसग्नल को पहले िोल्टेर् सर्काट के वसग्नल पर और क्रफर करिंट सर्काट के वसग्नल पर सुपरइ्पोज़ क्रकया र्ाएगा। पॉली-फेज़ मीटर के मामले में, सभी िोल्टेर् या करिंट सर्काट का परीक्षण एक ही समय में क्रकया र्ा सकता ह।ै मीटटरिंग त्रुरट को मापते समय वसग्नल की फ़्रीवेंसी को कम आिृवत्त से उच्च आिृवत्त तक और क्रफर िापस नीचे की ओर बदला र्ाएगा। परीक्षण की गिंभीरता: अतुल्यकावलक वसग्नल का मान 0.02 Unom और 0.1 Itr होगा, वर्समें ± 5% की सहनशीलता होगी। अवनिाया परीक्षण लबिंद:ु परीक्षण Itr पर क्रकया र्ाएगा। प्रत्येक हामोवनक आिृवत्त के वलए एक रीलडिंग ली र्ाएगी।
(4) गड़बवड़यों की र्ाँच,-
(i) गड़बवड़यों की र्ाँच के वलए साधारण वनदेश- ये परीक्षण यह सत्यावपत करने के वलए ह ैं क्रक मीटर गड़बड़ी के प्रभाि के वलए सारणी 5 में दी गई अपेक्षाओं को पूरा करता ह।ै परीक्षण एक समय में एक गड़बड़ी का उपयोग करके क्रकया र्ाना ह;ै अन्य सभी प्रभाि मात्राएँ सिंदभा शतों पर सेट की र्ाएिंगी र्ब तक क्रक सुसिंगत परीक्षण वििरण में अन्यथा न कहा गया हो। कोई महत्िपूणा गलती नहीं होगी. र्ब तक अन्यथा न कहा र्ाए, प्रत्येक परीक्षण में शावमल होगा क) यह र्ािंचना क्रक रवर्स्टर में कोई भी बदलाि या टेस्ट आउटपुट की बराबर ऊर्ाा, 3(3)(vi)(ख) में दी गई क्रिरटकल बदलाि िैल्यू से कम ह,ै56 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] ख) यह र्ािंचने के वलए ऑपरेशनल चेक क्रक करिंट वमलने पर मीटर ऊर्ाा ररकॉडा करता ह,ै ग) पल्स आउटपुट और टैररफ बदलने िाले इनपुट (अगर हों) के सही काम करने की र्ाचिं , और घ) माप द्वारा यह पुवष्ट करना क्रक वडस्टबेंस टेस्ट के बाद भी मीटर अवधकतम स्िीकाया त्रुरट की बुवनयादी ज़रूरतों को पूरा करता ह।ै काम करन े की क्षमता में कुछ समय के वलए रुकािट की अनुमवत ह,ै परन्तु रुकािट हटने पर मीटर अपने-आप सामान्य रूप से काम करने लगे। आधार की र्ािंच के वलए अवनिाया परीक्षण लबिंद अवधकतम अनुमेय त्रुरट हैं
1)I , PF = 1, tr
2) 10 I, PF = 0.5 इिंडक्टीि tr
(ii) बाहरी स्रोत का चुिंबकीय क्षेत्र (एसी, पािर आिृवत्त),- परीक्षण का उद्देश्य: बाहरी स्रोत की पािर फ़्रीवेंसी पर एसी चुिंबकीय क्षेत्र की वस्थवतयों के अधीन 3(3)(vi)(ख) और सारणी 5 की अपेक्षाओं के अनुपालन को सत्यावपत करने के वलए। परीक्षण विवध:: मीटर को सिंदभा िोल्टेर् से र्ोड़ा र्ाएगा, लेक्रकन करिंट सर्काट में कोई करिंट नहीं होगा। चुिंबकीय क्षेत्र को तीन लिंबित क्रदशाओं में लगाया र्ाएगा। अनुमत प्रभाि: कोई गिंभीर त्रुरट नहीं होगी। परीक्षण की गिंभीरता: चुिंबकीय क्षेत्र की तीव्रता, अल्प अिवध (3 सेकिंड): 1000 A/m.
(iii) वस्थरविद्युत वनिााह,- परीक्षण का उद्देश्य: प्रत्यक्ष और अप्रत्यक्ष इलेक्ट्ोस्टैरटक वडस्चार्ा की वस्थवतयों के अिंतगात 3(3)(vi)(ख) और सारणी 5 की अपेक्षाओं के अनुपालन को सत्यावपत करन े के वलए। इलेक्ट्ोमैकेवनकल मीटर र्सै े मीटर, र्ो केिल वनवष्िय तत्िों का उपयोग करके बनाए गए हैं, उन्ह ें इलेक्ट्ोस्टैरटक वडस्चार्ा के प्रवत प्रवतरवक्षत माना र्ाएगा। परीक्षण विवध: ईएसडी र्नरेटर का उपयोग सिंदर्भात मानक में वनर्दाष्ट प्रदशान विशेषताओं के साथ क्रकया र्ाना चावहए। परीक्षण शुरू करने से पहले, र्नरेटर के प्रदशान को सत्यावपत क्रकया र्ाना चावहए। सबसे सिंिेदनशील ध्रुिीयता में कम स ेकम 10 वडस्चार् ा लागू क्रकए र्ान ेचावहए। ग्राउिंड टर्मानल[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 57 से लैस नहीं होने िाले मीटर के वलए, मीटर को वडस्चार् ा के बीच पूरी तरह से वडस्चार्ा क्रकया र्ाना चावहए। सिंपका वडस्चार्ा पसिंदीदा परीक्षण विवध ह।ै र्हािं सिंपका वडस्चार् ा लागू नहीं क्रकया र्ा सकता िहािं एयर वडस्चार्ा का उपयोग क्रकया र्ाना चावहए। प्रत्यक्ष अनुप्रयोग: किंडवक्टि सतहों पर होने िाले कॉन्टैक्ट वडस्चार्ा मोड में, मीटर के साथ सिंपका होना अवनिाया ह।ै इिंसुलेटेड सतहों पर एयर वडस्चार्ा मोड में, इलेक्ट्ोड को मीटर के पास लाया र्ाता ह ै और स्पाका के माध्यम से वडस्चार् ा होता ह।ै अप्रत्यक्ष अनुप्रयोग: वडस्चार्ा को मीटर के वनकट वस्थत कपललिंग प्लेन पर सिंपका मोड में लागू क्रकया र्ाता ह।ै परीक्षण की शतें: परीक्षण मीटर के चाल ू वस्थवत में क्रकया र्ाएगा। िोल्टेर् सर्काट को Unom से सक्रिय क्रकया र्ाएगा और करिंट तथा सहायक सर्काट खुले रहगें े, वर्नमें कोई करिंट नहीं होगा। मीटर का परीक्षण टेबल-टॉप उपस्करके रूप में क्रकया र्ाएगा। अनुमत प्रभाि: कोई गिंभीर त्रुरट नहीं होगी। परीक्षण की गिंभीरता: कॉन्टैक्ट वडस्चार्ा िोल्टेर् (1): 8 kV एयर वडस्चार्ा िोल्टेर् (2): 15 kV रटप्पण (1): कॉन्टैक्ट वडस्चार्ा किंडवक्टि सतहों पर क्रकए र्ाने चावहए। रटप्पण (2): एयर वडस्चार्ा नॉन-किंडवक्टि सतहों पर क्रकए र्ाने चावहए।
(iv) तेज़ ट्ािंवर्एिंट्स,- परीक्षण का उद्देश्य: यह सत्यावपत करने के वलए क्रक 3(3)(vi)(ख) और सारणी 5 की अपेक्षाओं का अनुपालन उन वस्थवतयों में क्रकया र्ा रहा ह ै र्हाँ िोल्टेर् और करिंट सर्काट, और आई/ओ और सचिं ार पोटा पर इलेवक्ट्कल बस्टा सुपरइ्पोज़ क्रकए र्ाते हैं: इलेक्ट्ोमैकेवनकल मीटर र्ैसे मीटर, र्ो केिल वनवष्िय तत्िों का उपयोग करके बनाए गए हैं, उन्ह ें तज़े ट्ािंवर्एिंट्स के प्रवत प्रवतरवक्षत माना र्ाएगा। परीक्षण विवध: सिंदर्भात मानक में विवनर्दाष्ट प्रदशान विशेषताओं िाल े बस्टा र्नरेटर का उपयोग क्रकया र्ाएगा। मीटर को िोल्टेर् स्पाइक्स के बस्टा के अधीन क्रकया र्ाएगा, वर्सके वलए इ्पल्स की पुनरािृवत्त आिृवत्त और 50 ओम तथा 1000 ओम लोड पर आउटपुट िोल्टेर् के पीक मान सिंदर्भता मानक में पररभावषत ह।ैं मीटर र्ोड़ने से पहल े र्नरेटर की विशेषताओं को सत्यावपत क्रकया र्ाना चावहए। धनात्मक और ऋणात्मक दोनों ध्रुिीयता के बस्टा लाग ूक्रकए र्ाने चावहए। प्रत्येक आयाम और ध्रुिीयता के वलए परीक्षण की अिवध 1 वमनट स े कम नहीं होनी चावहए। मानक म ें पररभावषत अनुसार, 40 V से अवधक रेफरेंस िोल्टेर् िाली आई/ओ और सिंचार लाइनों को र्ोड़ने के वलए एक कैपेवसरटि कपललिंग क्लैंप का उपयोग क्रकया र्ाएगा। परीक्षण पल्स, माप58 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] समय के दौरान लगातार लाग ू क्रकए र्ाएिंगे। परीक्षण की वस्थवतया:िं मीटर का परीक्षण टेबल-टॉप उपस्करके रूप में क्रकया र्ाएगा। मीटर िोल्टेर् और सहायक सर्काट को रेफरेंस िोल्टेर् से एनर्ााइज़ क्रकया र्ाएगा। कपललिंग वडिाइस और मीटर के बीच के केबल की लिंबाई 1 मीटर होनी चावहए। टेस्ट िोल्टेर् को कॉमन मोड (लाइन-टू-अथा) में इन पर लागू क्रकया र्ाएगा क) िोल्टेर् सर्काट, ख) करिंट सर्काट, यक्रद सामान्य ऑपरेशन में िे िोल्टेर् सर्काट से अलग हों, ग) सहायक सर्काट, अगर सामान्य ऑपरेशन में िे िोल्टेर् सर्काट से अलग हों और उनका रेफरेंस िोल्टेर् 40 V से ज़्यादा हो। परीक्षण की गिंभीरता: करिंट और िोल्टेर् सर्काट पर परीक्षण िोल्टेर्: 4 kV 40 V से ज़्यादा रेफरेंस िोल्टेर् िाले ऑवक्सलरी सर्काट पर परीक्षण िोल्टेर्: 2 kV.
अनुमत प्रभाि: सिंदभा वस्थवतयों में वनवहत त्रुरट की तुलना में, त्रुरट में बदलाि सारणी 5 में सिंबिंवधत मीटर िगा के वलए वनधााररत मान से कम होना चावहए। अवनिाया परीक्षण लबिंद:ु 10 I, PF = 1. tr
(v) िोल्टेर् में वगरािट और रुकािटें - परीक्षण का उद्देश्य: कम समय के वलए मेन िोल्टेर् में कमी (वडप और रुकािट) की वस्थवतयों के अधीन 3(3)(vi)(ख) और सारणी 5 की अपेक्षाओं के अनुपालन को सत्यावपत करना। इलेक्ट्ोमैकेवनकल मीटर र्ैस े मीटर, र्ो केिल वनवष्िय तत्िों का उपयोग करके बनाए गए ह,ैं उन्ह ें िोल्टेर् में वगरािट और रुकािटों से अप्रभावित माना र्ाएगा। परीक्षण विवध: इस परीक्षण म ें एक ऐसे परीक्षण र्नरेटर का उपयोग क्रकया र्ाना चावहए र्ो ऑपरेटर द्वारा वनधााररत समय अिवध म ें एसी मेन िोल्टेर् के आयाम को कम करन े में सक्षम हो। मीटर र्ोड़न े स े पहले टेस्ट र्नरेटर के प्रदशान को सत्यावपत क्रकया र्ाना चावहए।[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 59 मेन िोल्टेर् म ें कटौती को कम से कम 10 सके िंड के अिंतराल के साथ 10 बार दोहराया र्ाना चावहए। परीक्षण की वस्थवतया:िं U स े एनर्ााइज़ क्रकए गए िोल्टेर् सर्काट nom करिंट सर्काट में वबना क्रकसी करिंट के। परीक्षण की गिंभीरता: िोल्टेर् म ें वगरािट:
परीक्षण परीक्षण क परीक्षण ख परीक्षण ग वगरािट: 30 % 60 % 60 % अिवध: 0.5 चि 1 चि 25 चि (50 Hz) 30 चि (60 Hz) िोल्टेर् रुकािट परीक्षण: वगरािट: 0 % अिवध: 250 चि (50 Hz) 300 चि (60 Hz) अनुमत प्रभाि: कोई गिंभीर त्रुरट नहीं होनी चावहए।
(vi) विक्रकरवणत, रेवडयो आिृवत्त (आरएफ), विद्युत चुिंबकीय क्षेत्र - परीक्षण का उद्देश्य: विक्रकरवणत, रेवडयो आिृवत्त, विद्युत चुिंबकीय क्षेत्र की वस्थवतयों के अधीन 3(3)(vi)(ख) और सारणी 5 की अपेक्षाओं के अनुपालन को सत्यावपत करना। इलेक्ट्ोमैकेवनकल मीटर र्सै े मीटर, र्ो केिल वनवष्िय तत्िों का उपयोग करके बनाए गए ह,ैं उन्ह ें विक्रकरवणत रेवडयो आिवृ त्त क्षेत्र स े अप्रभावित माना र्ाएगा। परीक्षण विवध: परीक्षण विवध के वलए 6.3.15.1 देखें। अनुमत प्रभाि: कोई गिंभीर त्रुरट नहीं होनी चावहए
(vii) एसी मेन पािर लाइनों में सर्ा,- परीक्षण का उद्देश्य: यह सत्यावपत करने के वलए क्रक 3(3)(vi)(ख) और सारणी 5 की अपेक्षाओं का अनपु ालन उन वस्थवतयों में क्रकया र्ा रहा ह ै र्हाँ मेन िोल्टेर् और, यक्रद लागू हो, तो आई/ओ और सिंचार पोटा पर इलेवक्ट्कल सर् ा आत े ह।ैं यह परीक्षण इलेक्ट्ोमैकेवनकल मीटर र्सै े मीटरों के वलए लागू नहीं ह,ै वर्न्ह ें सर्ा स े अप्रभावित माना र्ाएगा।60 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] परीक्षण विवध: सिंदर्भात मानक में विवनर्दाष्ट प्रदशान विशेषताओं िाले सर्ा र्नरेटर का उपयोग क्रकया र्ाएगा। परीक्षण में सर् ा के प्रवत एक्सपोज़र शावमल है, वर्सके वलए राइज़ टाइम, पल्स वि्थ, हाई/लो इ्पीडेंस लोड पर आउटपुट िोल्टेर्/करिंट के पीक मान, और दो लगातार पल्स के बीच न्यूनतम समय अिंतराल को सिंदर्भात मानक में पररभावषत क्रकया गया ह।ै मीटर र्ोड़ने से पहल े र्नरेटर की विशेषताओं को सत्यावपत क्रकया र्ाना चावहए। परीक्षण की वस्थवतया:िं मीटर काम कर रहा हो;
सामान्य िोल्टेर् से सक्रिय िोल्टेर् सर्काट; करिंट सर्काट में कोई करिंट नहीं होना चावहए और करिंट टर्मानल खुले होन े चावहए; सज़ा र्नरेटर और मीटर के बीच के केबल की लिंबाई: 1 मीटर; वडफरेंवशयल मोड (लाइन से लाइन) में परीक्षण क्रकया र्ाना चावहए;
चरण कोण: एसी सप्लाई के ज़ीरो िॉलसिंग के सिंदभा में 60° और 240° पर पल्स लागू क्रकए र्ाने चावहए। परीक्षण की गिंभीरता: िोल्टेर् सर्काट: • लाइन से लाइन: परीक्षण िोल्टेर्: • 2.0 kV, र्नरेटर स्रोत; प्रवतबाधा: 2 Ω;
• लाइन से अथा(1): परीक्षण िोल्टेर्: 4.0 kV; र्नरेटर स्रोत; प्रवतबाधा: 2 Ω; • परीक्षणों की सिंख्या: 5 धनात्मक और 5 ऋणात्मक; • पुनरािृवत्त दर: अवधकतम 1/वमनट। 40 V से अवधक रेफरेंस िोल्टेर् िाले सहायक सर्काट:
• लाइन से लाइन: परीक्षण िोल्टेर्: • 1.0 kV, र्नरेटर स्रोत; प्रवतबाधा: 42 Ω; • लाइन से अथा(1): परीक्षण िोल्टेर्: 2.0 kV; र्नरेटर स्रोत; प्रवतबाधा: 42 Ω; • परीक्षणों की सिंख्या: 5 धनात्मक और 5 ऋणात्मक; • पुनरािृवत्त दर: अवधकतम 1/वमनट। रटप्पण(1): उन मामलों के वलए र्हाँ मीटर की अर्थिंग न्यूट्ल से अलग होती ह।ै[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 61
(viii) डै्प्ड दोलन तरिंग प्रवतरक्षा परीक्षण- परीक्षण का उद्देश्य: डै्प्ड दोलन तरिंग की वस्थवत के अधीन 3(3)(vi)(ख) और सारणी 5 की अपेक्षाओं के अनुपालन को सत्यावपत करना। यह परीक्षण केिल उन मीटरों के वलए ह ै वर्न्ह ें िोल्टेर् ट्ािंसफॉमरा के साथ उपयोग क्रकया र्ाना ह।ै परीक्षण विवध: मीटर को नीचे दी गई परीक्षण गिंभीरता के अनुसार, पीक िोल्टेर् िाले डै्प्ड दोलन िोल्टेर् िेिफॉमा के अधीन क्रकया र्ाएगा। परीक्षण की वस्थवतया:िं मीटरों का परीक्षण टेबल-टॉप उपस्करके रूप में क्रकया र्ाएगा।;
मीटर काम कर रह े हों; सामान्य िोल्टेर् से सक्रिय िोल्टेर् सर्काट;
I = 20 I और पािर फैक्टर एक तथा 0.5 इिंडवक्टि के साथ। tr परीक्षण की गिंभीरता: 40 V से अवधक ऑपरेटटिंग िोल्टेर् िाले िोल्टेर् सर्काट और सहायक सर्काट पर िोल्टेर् परीक्षण: • कॉमन मोड: 2.5 kV; • वडफरेंवशयल मोड: 1.0 kV;
परीक्षण आिृवत्तयाँ: • 100 kHz, पुनरािृवत्त दर: 40 Hz; • 1 MHz, पुनरािृवत्त दर: 400 Hz; परीक्षण अिवध: 60 सेकिंड (प्रत्येक आिृवत्त के वलए 2 सेकिंड चालू, 2 सेकिंड बिंद के 15 चि)। अनुमत प्रभाि: परीक्षण के दौरान मीटर के काया में कोई बाधा नहीं आनी चावहए और त्रुरट में बदलाि सारणी 5 में दी गई सीमाओं से कम होना चावहए। अवनिाया परीक्षण लबिंद:ु 20 I, PF = 1 और 0.5 इिंडवक्टि। tr
(ix) अल्पकावलक ओिरकरिंट,- परीक्षण का उद्देश्य: अल्पकावलक ओिरकरिंट की वस्थवत के अधीन 3(3)(vi)(ख) और सारणी 5 की अपेक्षाओं के अनुपालन को सत्यावपत करना। परीक्षण विवध: र्ब मापे र्ा रह े लोड को सही फ़्यूज़ या ब्रेकर स े सुरवक्षत क्रकया गया हो, तो मीटर को उस लोड के अिंदर शॉटा-सर्काट से होने िाले करिंट को सिंभालन े में सक्षम होना चावहए। परीक्षण करिंट: सीधे र्ुड़े मीटरों के वलए: रेटेड आिृवत्त या समकक्ष पर आधे चि के वलए 30·I +0 % – अवधकतम 10 %. करिंट ट्ािंसफॉमरा के माध्यम से र्ुड़े मीटरों के वलए:
0.5 सेकिंड के वलए 20·I +0 % –10 % के बराबर करिंट। अवधकतम62 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] परीक्षण करिंट को एक समय में एक ही चरण पर लागू क्रकया र्ाएगा। परीक्षण करिंट का क्रदया गया मान r.m.s. मान ह,ै न क्रक वशखर मान। अनुमत प्रभाि: कोई क्षवत नहीं होनी चावहए। िोल्टेर् पुनः र्ोड़ने पर, मीटर को सामान्य तापमान पर लौटन े क्रदया र्ाएगा (लगभग 1 घिंटा)। परीक्षण से पहले की प्रारिंवभक त्रुरट की तुलना में, त्रुरट में बदलाि सारणी 5 में दी गई त्रुरट बदलाि की सीमा स े कम होना चावहए। अवनिाया परीक्षण लबिंद:ु 10 I, PF = 1.
tr
(x) आिेग िोल्टेर्,- (क) साधारण,- परीक्षण का उद्देश्य: आिेग िोल्टेर् की वस्थवत के अधीन 3(3)(vi)(ख) और सारणी 5 की अपेक्षाओं के अनुपालन को सत्यावपत करना। साधारण परीक्षण विवध: मीटर और उसस े र्ुड़े अवतररक्त उपस्कर(यक्रद कोई हों) ऐसे होन े चावहए क्रक िे उपयोग की सामान्य वस्थवतयों में िायुमिंडलीय प्रभािों और अलग-अलग िोल्टेर् के बािर्ूद अपने पयााप्त डाइइलेवक्ट्क गुण बनाए रखें। मीटर को नीच े वनर्दाष्ट आिेग िोल्टेर् परीक्षण को पास करना होगा। परीक्षण केिल पूणा मीटरों पर ही क्रकया र्ाएगा।.
इस परीक्षण के उद्देश्य के वलए, "अथा" शब्द का अथा वनम्नवलवखत ह:ै क) र्ब मीटर का आिरण धातु का बना हो, तो 'अथा' िह आिरण होता ह,ै वर्से एक समतल, सिंिाहक सतह पर रखा र्ाता है; ख) यक्रद मीटर का आिरण या उसका केिल कुछ भाग कुचालक पदाथा से बना है, तो "अथा" एक सिंिाहक पन्नी ह ैर्ो मीटर के चारों ओर वलपटी होती है, र्ो सभी सुलभ सिंिाहक भागों को स्पशा करती ह ैऔर उस समतल, सििं ाहक सतह स े र्ुड़ी होती ह ैवर्स पर मीटर रखा गया ह।ै सिंिाहक पन्नी और टर्मानलों के बीच, और सिंिाहक पन्नी और चालकों के वछरों के बीच की दरू ी 2 सेमी से अवधक नहीं होनी चावहए। आिेग िोल्टेर् परीक्षण के दौरान, वर्न सर्काटों का परीक्षण नहीं क्रकया र्ा रहा है, उन्ह ें अथा स े र्ोड़ा र्ाना चावहए। साधारण पररिेश का तापमान: 15 °C से 25 °C;
परीक्षण की वस्थवतया:िं सापेक्ष आराता: 25 % से 75 %; िायु - दाब: 86 kPa से 106 kPa.[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 63 अनुमत प्रभाि: आिेग िोल्टेर् परीक्षण पूरा होने के बाद, मीटर में कोई क्षवत नहीं होनी चावहए और न ही कोई महत्िपूणा खराबी आनी चावहए। (ख) आिेग िोल्टेर् परीक्षण प्रक्रिया,- परीक्षण की वस्थवतया:िं आिेग िेिफॉम:ा 1.2/50 µs आिेग िोल्टेर् िृवद् समय: ± 30 %;
िोल्टेर् पतन समय: ± 20 %; स्रोत ऊर्ा:ा 10.0 J ± 1.0 J; परीक्षण िोल्टेर्: सारणी 15 के अनसु ार; परीक्षण िोल्टेर् सहनशीलता: +0 –10 %. रटप्पण: सोसा इ्पीडेंस का चयन परीक्षण प्रयोगशाला के वििेक पर वनभार करता ह।ै प्रत्येक परीक्षण (6(4)(x)(ग) और 6(4)(x)(ड) देख)ें के वलए, आिेग िोल्टेर् को एक ध्रुिीयता के साथ दस बार और क्रफर दसू री ध्रुिीयता के साथ दस बार लगाया र्ाता ह।ै आिेगों के बीच न्यूनतम समय 30 सेकिंड होना चावहए। सारणी 15 आिेग िोल्टेर् परीक्षण स्तर रेटेड वसस्टम िोल्टेर् से व्युत्पन्न फेज़-टू-अथा वनधााररत आिेग िोल्टेर् (V) िोल्टेर् (V) V ≤100 3 000 100 < V ≤150 6 000 150 < V ≤300 10 000 300 < V ≤600 12 000 (ग) सर्काटों के वलए और सर्काटों के बीच आिेग िोल्टेर् परीक्षण,- परीक्षण प्रक्रिया: यह परीक्षण हर उस सर्काट (या सर्काट असेंबली) पर अलग से क्रकया र्ाएगा र्ो सामान्य उपयोग में मीटर के अन्य सर्काटों से इिंसुलेटेड रहता ह।ै वर्न सर्काटों पर आिेग िोल्टेर् का परीक्षण नहीं होना ह,ै उनके टर्मानलों को अथा से र्ोड़ा र्ाएगा। इसवलए, र्ब सामान्य इस्तेमाल के दौरान क्रकसी मापने िाले एवलमेंट के िोल्टेर् और करिंट सर्काट को एक साथ र्ोड़ा र्ाता ह,ै तो पूरी प्रणाली का परीक्षण क्रकया र्ाना चावहए। िोल्टेर् सर्काट के दसू रे वसरे को अथा स े र्ोड़ा र्ाना चावहए और करिंट सर्काट के टर्मानल और अथ ा के बीच आिेग िोल्टेर् लगाया र्ाना चावहए। र्ब मीटर के कई िोल्टेर् सर्काट में एक सामान्य लबिंद ुहो, तो उस लबिंद ुको अथा से र्ोड़ा र्ाना चावहए और कनेक्शन के प्रत्येक मुक्त वसरे (या उससे र्ुड़े करिंट सर्काट)64 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] और अथ ाके बीच िवमक रूप से इ्पल्स िोल्टेर् लगाया र्ाना चावहए। इस करिंट सर्काट का दसू रा वसरा खुला होना चावहए। र्ब सामान्य उपयोग में एक ही मापन तत्ि के िोल्टेर् और करिंट सर्काट अलग-अलग हों और उन्ह ें उवचत रूप स े इिंसुलेट क्रकया गया हो (उदाहरण के वलए, प्रत्येक सर्काट मापन ट्ासिं फामार स े र्ुड़ा हो), तो परीक्षण प्रत्येक सर्काट पर अलग-अलग क्रकया र्ाएगा। करिंट सर्काट के परीक्षण के दौरान, अन्य सर्काटों के टर्मानलों को अथा से र्ोड़ा र्ाएगा और करिंट सर्काट के क्रकसी एक टर्मानल और अथा के बीच आिेग िोल्टेर् लगाया र्ाएगा। िोल्टेर् सर्काट के परीक्षण के दौरान, अन्य सर्काटों के टर्मानलों और परीक्षण के अधीन िोल्टेर् सर्काट के एक टर्मानल को अथा स े र्ोड़ा र्ाएगा और िोल्टेर् सर्काट के दसू रे टर्मानल और अथा के बीच आिेग िोल्टेर् लगाया र्ाएगा। वर्न सहायक सर्काटों को सीधे मुख्य आपूर्ता या मीटर सर्काट के समान िोल्टेर् ट्ािंसफामार स े र्ोड़ा र्ाना ह ै और वर्नका वनदेश िोल्टेर् 40 V से अवधक ह,ै उन्ह ें परीक्षण के दौरान िोल्टेर् सर्काट के साथ र्ोड़कर आिगे िोल्टेर् परीक्षण के अधीन क्रकया र्ाएगा। अन्य सहायक सर्काटों का परीक्षण नहीं क्रकया र्ाएगा। (घ) अथा के सापेक्ष इलेवक्ट्क सर्काट का आिेग िोल्टेर् परीक्षण,- परीक्षण प्रक्रिया: मीटर के इलेवक्ट्क सर्काट के सभी टर्मानल, वर्नमें 40 V से ज़्यादा वनदेश िोल्टेर् िाले सहायक सर्काट के टर्मानल भी शावमल ह,ैं को आपस में र्ोड़ा र्ाना चावहए। 40 V या उससे कम वनदेश िोल्टेर् िाले सहायक सर्काट को अथ ा स े र्ोड़ा र्ाना चावहए। सभी इलेवक्ट्क सर्काट और अथा के बीच आिेग िोल्टेर् लगाया र्ाना चावहए। अनुज्ञात प्रभाि: इस परीक्षण के दौरान कोई फ़्लैशओिर, वडसरवप्टि वडस्चार्ा या पिंचर नहीं होना चावहए।
(xi) अथा दोष ,- परीक्षण का उद्देश्य: अथा दोष की वस्थवत के अधीन 3(3)(vi)(ख) और सारणी 5 के उपबिंघो के अनुपालन को सत्यावपत करना। यह परीक्षण केिल उन थ्री-फेर् फोर-िायर ट्ािंसफामार-सिंचावलत मीटरों पर लाग ू होता ह ै र्ो ऐसे वितरण नेटिका से र्ुड़ े ह ैं वर्नमें अथा दोष न्यूट्लाइज़र लगे ह ैं या वर्नमें स्टार पॉइिंट आइसोलेटेड अथा दोष और 10% ओिरिोल्टेर् की वस्थवत में, दोष से अप्रभावित दो लाइनों का लाइन-टू-अथा िोल्टेर्, नॉवमनल िोल्टेर् के 1.9 गनु ा तक बढ र्ाएगा।[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 65 परीक्षण प्रक्रिया: वनम्नवलवखत परीक्षण अपेक्षाएिं लाग ू होंगी:
तीन लाइनों में स े एक में वस्युलेटेड अथा दोष की वस्थवत के परीक्षण के वलए, सभी िोल्टेर् को 4 घिंटे तक नॉवमनल िोल्टेर् के 1.1 गुना तक बढाया र्ाएगा। परीक्षण के अधीन मीटर के न्यूट्ल टर्मानल को मीटर परीक्षण उपस्कर(एमटीई) के ग्राउिंड टर्मानल से अलग क्रकया र्ाता ह ै और एमटीई के उस लाइन टर्मानल से र्ोड़ा र्ाता ह ै र्हाँ अथा दोष को वसमुलेट करना ह ै (वचत्र 5 देख)ें । इस प्रकार, परीक्षण के अधीन मीटर के िे दो िोल्टेर् टर्मानल, र्ो अथा दोष से प्रभावित नहीं होते ह,ैं उन्ह ें नॉवमनल फेज़ िोल्टेर् के 1.9 गुना से र्ोड़ा र्ाता ह।ै अनुज्ञात प्रभाि: परीक्षण के पिात , मीटर में कोई क्षवत नहीं होनी चावहए और उस े सही ढिंग से काम करना चावहए। र्ब मीटर िापस सामान्य कायाशील तापमान पर आ र्ाए, तो मापी गई त्रुरट म ेंबदलाि सारणी 5 में विवनर्दाष्ट गई सीमाओं स े अवधक नहीं होना चावहए। अवनिाया परीक्षण लबिंद:ु 10 I , ऊर्ाा घटक = 1, सतिं वु लत भार। tr
(xii) सहायक युवक्तयों का प्रचालन ,- परीक्षण का उद्देश्य: सहायक युवक्तयों के प्रचालन की वस्थवतयों के अधीन 3(3)(vi)(ख) और सारणी 5 के उपबिंधो के अनुपालन को सत्यावपत करना। सहायक युवक्तयों के प्रचालन का परीक्षण यह सुवनवित करन े के वलए क्रकया र्ाएगा क्रक िे मीटर के मापविज्ञान प्रदशान को प्रभावित न करें।66 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] परीक्षण प्रक्रिया: इस परीक्षण में, मीटर को वनदेश वस्थवतयों पर सिंचावलत क्रकया र्ाएगा और इसके त्रुरट की वनरिंतर मॉवनटरी की र्ाएगी, र्बक्रक सिंचार युवक्तयों, ररले और अन्य आई/ओ सर्काट र्ैस े सहायक युवक्तयों को भी सचिं ावलत क्रकया र्ाएगा। अनुज्ञात प्रभाि: मीटर की कायाक्षमता प्रभावित नहीं होनी चावहए और सहायक युवक्तयों के प्रचालन के कारण त्रुरट में बदलाि हमेशा सारणी 5 म ें सूचीबिंध त्रुरट बदलाि सीमा से कम होना चावहए। अवनिाया परीक्षण लबिंद:ु PF = 1 पर I और I at.
tr अवधकतम
(xiii) यािंवत्रक परीक्षण,- (क) किंपन,- परीक्षण का उद्देश्य: किंपन की वस्थवत के अधीन 3(3)(vi)(ख) और सारणी 5 के उपबिंधो के अनुपालन को सत्यावपत करना। परीक्षण विवध: इसके पिात्, मीटर को उसके सामान्य माउिंटटिंग तरीके से एक मज़बूत क्रफक्स्चर पर लगाकर तीन परस्पर लिंबित अक्षों में परीक्षण क्रकया र्ाएगा। मीटर को आम तौर पर इस तरह लगाया र्ाना चावहए क्रक गुरुत्िाकषाण बल उसी क्रदशा में काम करे र्ैसा सामान्य इस्तेमाल के दौरान होता ह।ै र्हा ँ गुरुत्िाकषाण बल का असर महत्िपूणा नहीं ह,ै िहाँ मीटर को क्रकसी भी वस्थवत में लगाया र्ा सकता ह।ै परीक्षण की गिंभीरता:
कुल आिृवत्त सीमा 10 – 150 Hz कुल r.m.s. स्तर 7 m·s–2 एक्सेलरेशन स्पेक्ट्ल डेंवसटी (एएसडी) स्तर 10 1 m2·s–3 – 20 Hz एक्सेलरेशन स्पेक्ट्ल डेंवसटी (एएसडी) स्तर 20 –3 dB/ऑक्टेि – 150 Hz प्रवत अक्ष अिवध: कम से कम 2 वमनट। अनुज्ञात प्रभाि: परीक्षण के पिात, मीटर की कायाक्षमता प्रभावित नहीं होनी चावहए और 10 I पर त्रुरट म ें tr बदलाि सारणी 5 में सूचीबधिं त्रुरट बदलाि सीमा से अवधक नहीं होना चावहए। अवनिाया परीक्षण लबिंद:ु 10 I, PF = 1.
tr[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 67 (ख) झटका,- परीक्षण का उद्देश्य: झटके की वस्थवत के अधीन 3(3)(vi)(ख) और सारणी 5 के उपबिंधो के अनुपालन को सत्यावपत करना। परीक्षण विवध: मीटर को विवनर्दाष्ट उच्च त्िरण और अिवध के मानक पल्स आकारों के गैर-पुनरािती झटकों के अधीन क्रकया र्ाता ह।ै परीक्षण के दौरान, मीटर चालू नहीं होना चावहए और इसे एक क्रफक्स्चर या शॉक-परीक्षण मशीन से बािंधा र्ाना चावहए। परीक्षण की गिंभीरता: पल्स का आकार: हाफ-साइन;
अवधकतम त्िरण: 30 g (300 ms-2); n पल्स की अिवध: 18 ms. अनुज्ञात प्रभाि: परीक्षण के पिात्, मीटर की कायाक्षमता प्रभावित नहीं होनी चावहए और 10 Itr पर त्रुरट में बदलाि सारणी 5 में सचू ीबिंध त्रुरट बदलाि सीमा से अवधक नहीं होना चावहए। अवनिाया परीक्षण लबिंद:ु 10 I, PF = 1.
tr
(xiv) सौर विक्रकरण स े सुरक्षा,- परीक्षण का उद्देश्य: सौर विक्रकरण से सुरक्षा के सिंबिंध में 3(5), 3(6)(i), 3(7)(i) और 3(3)(vi)(ख) की अपेक्षाओं के अनुपालन को सत्यावपत करना। वसफा बाहर लगे मीटरों के वलए। परीक्षण की वस्थवतया:िं गैर-पररचालन वस्थवत में मीटर। परीक्षण उपस्कर: लैंप का प्रकार/िेिलेंथ: यूिीए 340;
ब्लैक पैनल थमाामीटर; लाइट मीटर; परीक्षण वस्थवतयों के मापदिंडों का पालन करने के वलए किंडेनसेशन चि िाला साइकललिंग ररग। परीक्षण की वस्थवतया:िं गैर-पररचालन वस्थवत में मीटर परीक्षण चि (12 लैंप का प्रकार स्पेक्ट्ल विक्रकरण ब्लैक पैनल का तापमान घिंटे की चि) 8 घिंटे सूखा यूिीए 340 340 nm पर 0.76 60 ± 3 °C68 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] W·m–2· nm–1 4 घिंटे सिंघनन लाइट बिंद 50 ± 3 °C परीक्षण विवध सिंक्षेप में: बाद में तुलना करन े के वलए मीटर के एक भाग को आिंवशक रूप स े ढक दें। मीटर को 66 क्रदनों (132 चिों) की अिवध के वलए और ऊपर दी गई परीक्षण वस्थवतयों के अनुसार कृवत्रम विक्रकरण और मौसम के प्रभाि के सिंपका में रखें। परीक्षण के बाद मीटर का दश्ृ य वनरीक्षण क्रकया र्ाएगा और एक कायाात्मक परीक्षण क्रकया र्ाएगा। मीटर की क्रदखािट और विशेष रूप से, मार्किंग और वडस्प्ले की स्पष्टता में कोई पररितान नहीं होना चावहए। मापविज्ञान सिंबिंधी गुणों की सुरक्षा के क्रकसी भी साधन, र्ैसे क्रक केस और सीललिंग, पर कोई प्रभाि नहीं पड़ेगा। मीटर की कायाक्षमता प्रभावित नहीं पड़ेगा।
(xv) धूल के प्रिेश से सुरक्षा,- परीक्षण का उद्देश्य: धूल के प्रिेश से सुरक्षा के सिंबिंध में 3(3)(vi)(ख) और सारणी 5 के उपबिंधो के अनुपालन को सत्यावपत करना। परीक्षण की वस्थवतया:िं वनदेश वस्थवतयािं; आईपी 5X रेटटिंग;
श्रेणी 2 एनक्लोज़र। परीक्षण विवध: परीक्षण के बाद मीटर का दश्ृ य वनरीक्षण क्रकया र्ाएगा और एक कायात्ा मक परीक्षण क्रकया र्ाएगा। अनुज्ञात प्रभाि: परीक्षण में प्रयुक्त टैल्कम पाउडर या अन्य धूल इतनी मात्रा में या ऐसे स्थान पर र्मा नहीं होनी चावहए क्रक िह उपस्करके सही प्रचालन में बाधा डाले या सुरक्षा को खतरे में डाले। धूल को िहािं र्मा नहीं होना चावहए र्हािं िह िीपेर् दरू ी के साथ ट्ैककिंग का कारण बन सके। मीटर की कायाक्षमता प्रभावित नहीं होनी चावहए।
(xvi)र्लिायु सिंबिंधी परीक्षण,- (क) चरम तापमान - सूखी गमी,- परीक्षण का उद्देश्य: सूखी गमी की वस्थवत में 3(3)(vi)(ख) और सारणी 5 के उपबिंधो के अनुपालन को सत्यावपत करना। परीक्षण विवध: परीक्षण में मीटर को गैर-पररचालन वस्थवत में रखते हुए, 'मुक्त िायु' वस्थवतयों में विवनर्दाष्ट उच्च तापमान के सिंपका में 2 घिंटे तक रखना शावमल ह ै (यह समय मीटर का तापमान वस्थर होने पर शुरू होता ह)ै ।[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 69 गम ा और ठिंडा करते समय तापमान में बदलाि 1 °C/वमनट स े ज़्यादा नहीं होना चावहए। परीक्षण िातािरण की वनरपक्षे आराता 20 g/m3 स े अवधक नहीं होनी चावहए। परीक्षण की गिंभीरता: परीक्षण मीटर के वलए विवनर्दाष्ट ऊपरी तापमान सीमा से एक चरण अवधक मानक तापमान पर क्रकया र्ाएगा। सिंभावित तापमान: 40 °C 55 °C 70 °C 85 °C.
अनुज्ञात प्रभाि: परीक्षण के बाद, मीटर की कायाक्षमता प्रभावित नहीं होनी चावहए और त्रुरट में बदलाि सारणी 5 में सूचीबद् त्रुरट बदलाि सीमा से अवधक नहीं होना चावहए। अवनिाया परीक्षण लबिंद:ु 10 I, PF = 1. tr (ख) चरम तापमान – ठिंडक,- परीक्षण का उद्देश्य: कम तापमान की वस्थवत में 3(3)(vi)(ख) और सारणी 5 के उपबिंधो के अनुपालन को सत्यावपत करना। परीक्षण विवध: परीक्षण में मीटर को गैर-पररचालन वस्थवत में रखत े हुए, 'मुक्त िायु' वस्थवतयों में विवनर्दाष्ट कम तापमान के सिंपका में 2 घिंटे तक रखना शावमल ह ै (यह समय मीटर का तापमान वस्थर होने पर शुरू होता ह)ै । गम ा और ठिंडा करते समय तापमान में बदलाि 1 °C/वमनट स े ज़्यादा नहीं होना चावहए। परीक्षण की गिंभीरता: परीक्षण मीटर के वलए विवनर्दाष्ट वनचली तापमान सीमा से एक चरण कम मानक तापमान पर क्रकया र्ाएगा। सिंभावित तापमान: –10 °C –25 °C –40 °C –55 °C(1).
अनुज्ञात प्रभाि: परीक्षण के बाद, मीटर की कायाक्षमता प्रभावित नहीं होनी चावहए और त्रुरट में बदलाि सारणी 5 में सूचीबद् त्रुरट बदलाि सीमा से अवधक नहीं होना चावहए। अवनिाया परीक्षण लबिंद:ु 10 I, PF = 1. tr70 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] रटप्पण (1): यक्रद विवनर्दाष्ट न्यूनतम तापमान –55 ºC ह,ै तो यह परीक्षण –55 ºC पर क्रकया र्ाएगा। (ग) नमी क्लास एच1 के वलए नम गमी, वस्थर-अिस्था (वबना सिंघनन िाली),- परीक्षण का उद्देश्य: उच्च आराता और वस्थर तापमान की वस्थवतयों में सारणी 4, 3(3)(vi)(ख) और सारणी 5 के उपबिंधो के अनुपालन को सत्यावपत करना। उन मीटरों के वलए र्ो बिंद स्थानों के वलए वनर्दाष्ट ह,ैं र्हाँ मीटरों पर सघिं वनत पानी, िषाा या बफा नहीं र्मती ह ै (एच1)। परीक्षण विवध: परीक्षण में विवनर्दाष्ट उच्च तापमान और गिंभीरता स्तर द्वारा पररभावषत एक वनवित समय के वलए विवनर्दाष्ट वस्थर सापेक्ष आराता के सिंपका में रखना शावमल ह।ै मीटर को इस तरह से सिंभाला र्ाना चावहए क्रक उस पर पानी का सिंघनन न हो। परीक्षण की वस्थवतया:िं वनदेश िोल्टेर् से सक्रिय क्रकए गए िोल्टेर् और सहायक सर्काट;
करिंट सर्काट में वबना क्रकसी करिंट के परीक्षण की गिंभीरता: तापमान: 30 °C; आराता: 85 %; अिवध: 2 क्रदन अनुज्ञात प्रभाि: परीक्षण के दौरान कोई महत्िपूणा खराबी नहीं होनी चावहए। परीक्षण के तुरिंत बाद मीटर को सही ढिंग स े काम करना चावहए और सारणी 4 की सटीकता अपेक्षाओं का अनुपालन करना चावहए। परीक्षण के 24 घिंटे बाद मीटर का कायाात्मक परीक्षण क्रकया र्ाएगा, वर्सके दौरान यह प्रदर्शात क्रकया र्ाएगा क्रक यह सही ढिंग से काम कर रहा ह।ै यािंवत्रक क्षवत या र्िंग का कोई वनशान नहीं होना चावहए, र्ो मीटर के कायाात्मक गुणों को प्रभावित कर सकता ह।ै (घ) नमी क्लास एच2 और एच3 के वलए नम गमी, चिीय (सिंघनन),- परीक्षण का उद्देश्य: उच्च आराता और वस्थर तापमान की वस्थवतयों में सारणी 4, 3(3)(vi)(ख) और सारणी 5 के उपबिंधो के अनुपालन को सत्यावपत करना। यह परीक्षण उन मीटरों पर लागू होता ह ै वर्नकी आराता िगा विवशष्टता या तो बिंद स्थानों के वलए ह ै र्हाँ मीटर सिंघवनत पानी के सिंपका में आ सकते ह,ैं या खुले स्थानों के वलए ह ै (आराता िगा एच2 और एच3)। परीक्षण विवध: परीक्षण में 25°C और नीचे दी गई परीक्षण गिंभीरता के अनुसार विवनर्दाष्ट ऊपरी तापमान के बीच चिीय तापमान वभन्नता के सिंपका में आना शावमल है, र्बक्रक तापमान पररितान और कम तापमान िाले चरणों के दौरान सापेक्ष आराता को 95% से ऊपर, और ऊपरी तापमान िाल े चरणों के दौरान 93% पर बनाए रखा र्ाता ह।ै तापमान बढने के दौरान मीटर पर सिंघनन होना चावहए। 24 घिंटे के चि में शावमल ह ैं
1) 3 घिंटे तक तापमान में िृवद्,
2) चि शुरू होने से 12 घिंटे तक तापमान को ऊपरी स्तर पर बनाए रखना,[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 71
3) 3 से 6 घिंटे के भीतर तापमान को वनचले स्तर तक कम करना, वर्समें पहल े डढे घिंटे में वगरािट की दर ऐसी होनी चावहए क्रक 3 घिंटे में वनचला स्तर प्राप्त हो र्ाए,
4) 24 घिंटे का चि पूरा होन े तक तापमान को वनचले स्तर पर बनाए रखना। साइवक्लक एक्सपोज़र स े पहले की वस्थरता अिवध और बाद की ररकिरी अिवध ऐसी होनी चावहए क्रक मीटर के सभी भाग अपने अिंवतम तापमान के 3 °C के भीतर हों। परीक्षण की वस्थवतया:िं वनदेश िोल्टेर् से सक्रिय क्रकए गए िोल्टेर् और सहायक सर्काट;
करिंट सर्काट में वबना क्रकसी करिंट के; विवनमााता के विवनदेशों के अनुसार माउिंटटिंग वस्थवत। परीक्षण की गिंभीरता: वर्न मीटरों में बिंद स्थानों के वलए आराता िगा विवनदेश ह,ै र्हा ँ मीटरों पर सिंघवनत र्ल र्मा हो सकता ह,ै उनका परीक्षण गिंभीरता स्तर 1 पर क्रकया र्ाएगा। खुल ेस्थानों के वलए आराता िगा विवनदेश िाल े मीटरों का परीक्षण गिंभीरता स्तर 2 पर क्रकया र्ाएगा। विवनर्दाष्ट आराता श्रेणी : एच2 एच3 अनुज्ञात प्रभाि: गिंभीरता स्तर: 1 2 ऊपरी तापमान (°C): 40 55 अिवध (चि): 2 2 परीक्षण के दौरान कोई महत्िपूणा खराबी नहीं होनी चावहए। परीक्षण के तुरिंत बाद मीटर को सही ढिंग स े काम करना चावहए और सारणी 4 की सटीकता अपेक्षाओं का अनुपालन करना चावहए। परीक्षण के 24 घिंटे बाद मीटर का कायाात्मक परीक्षण क्रकया र्ाएगा, वर्सके दौरान यह प्रदर्शात क्रकया र्ाएगा क्रक यह सही ढिंग से काम कर रहा ह।ै यािंवत्रक क्षवत या र्िंग का कोई वनशान नहीं होना चावहए, र्ो मीटर के कायाात्मक गुणों को प्रभावित कर सकता ह।ै (ङ) र्ल परीक्षण,- परीक्षण का उद्देश्य: बाररश और पानी के छींटें पड़ने की वस्थवतयों में 3(3)(vi)(ख) और सारणी 5 के उपबिंधो के अनुपालन को सत्यावपत करना। यह परीक्षण उन मीटरों के वलए लागू ह ै र्ो खुल े स्थानों (एच3) के वलए वनर्दाष्ट ह।ैं परीक्षण विवध: मीटर को एक उपयुक्त क्रफक्स्चर पर लगाया र्ाता ह ैऔर उस पर पानी की बौछार या छींटों की नकल करने के वलए ऑवसलेटटिंग ट्यूब या स्प्रे नोज़ल से वनकलने िाल े पानी की बौछार डाली र्ाती ह।ै72 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] परीक्षण की वस्थवतया:िं परीक्षण के दौरान मीटर चालू होना चावहए;
फ़्लो रेट (प्रवत नोज़ल): 0.07 ली/वमनट; अिवध: 10 वमनट; झुकाि का कोण: 0° और 180° अनुज्ञात प्रभाि: परीक्षण के दौरान कोई महत्िपूणा खराबी नहीं होनी चावहए। परीक्षण के तुरिंत बाद मीटर को सही ढिंग से काम करना चावहए और सारणी 2 की सटीकता अपेक्षाओं का अनुपालन करना चावहए। परीक्षण के 24 घिंटे बाद मीटर का कायाात्मक परीक्षण क्रकया र्ाएगा, वर्सके दौरान यह प्रदर्शात क्रकया र्ाएगा क्रक यह सही ढिंग से काम कर रहा ह ै और सारणी 2 की सटीकता अपेक्षाओं का अनुपालन कर रहा ह।ै याविं त्रक क्षवत या र्िंग का कोई वनशान नहीं होना चावहए, र्ो मीटर के कायाात्मक गुणों को प्रभावित कर सकता ह।ै
(xvii) रटकाऊपन का परीक्षण,- परीक्षण का उद्देश्य: रटकाऊपन के वलए 3(8) और सारणी 5 के उपबिंधों के अनुपालन को सत्यावपत करना परीक्षण विवध: विद्युत मीटरों की रटकाऊपन की र्ािंच करने के वलए परीक्षण क्रकया र्ाएगा। अवनिाया परीक्षण लबिंद:ु प्रारिंवभक और अिंवतम माप के वलए, िोल्टेर् U होना चावहए, और परीक्षण लबिंद ुइस nom प्रकार होंगे: I, 10 I, और PF = 1पर I .
tr tr max
7. प्रकार मूल्यािंकन और अनमु ोदन- प्रकार मूल्यािंकन के वलए र्ािंच यह तय करेगी क्रक क्या मीटर खिंड 3 की सभी अपेक्षाओं का अनुपालन करता ह ै और क्या विवनमााता द्वारा प्रदान क्रकए गए दस्तािेज़ खिंड 4(1) की आिश्यकताओं का अनपु ालन करते ह।ैं क्रकसी मीटर को प्रकार अनमु ोदन में तभी पास माना र्ाएगा र्ब सभी प्रकार परीक्षणों के पररणाम खिंड 3 में दी गई अपेक्षाओं का अनुपालन करते हों। माप की अवनवितता इतनी कम होनी चावहए क्रक उत्तीणा और अनुत्तीणा पररणामों के बीच स्पष्ट अिंतर क्रकया र्ा सके। विशेष रूप से, सिंबिंवधत परीक्षण लबिंद ु के वलए दी गई अवधकतम अनुमेय त्रुरट के पािंचिें वहस्से स े कम की अवनवितता खिंड 6(2) में िर्णात परीक्षणों के वलए प्राप्त की र्ानी चावहए, र्ब तक क्रक सुसिंगत परीक्षण वििरण में अन्यथा विवनर्दाष्ट न क्रकया गया हो। क्रकए गए परीक्षणों का दायरा और उपयोग की गई परीक्षण गिंभीरता विवनमााता के विवनदेशों और खिंड 3 की अपेक्षाओं के अनुरूप होनी चावहए।[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 73
8. सत्यापन,-
(1) साधारण - सत्यापन अलग-अलग क्रकया र्ा सकता ह।ै सभी मामलों में मीटरों को इस अवधसचू ना की अपक्षे ाओं का पालन करना होगा। बाद के सत्यापन और सेिा के दौरान वनरीक्षण के वलए स्िीकाया अवधकतम त्रुरटयों की आधारभूत सीमा िही होगी र्ो 3(3)(iii) में दी गई ह।ै सभी मीटरों का प्रारिंवभक सत्यापन और मर्मत क्रकए गए या अन्यथा बदले गए मीटरों का पुन: सत्यापन क्रकया र्ाएगा। उपयोग में आने िाले मीटरों की पुन: सत्यापन अिवध नीचे सारणी क और ख में दी गई ह:ै सारणी क इलेक्ट्ो-मैकेवनकल इिंडक्शन-प्रकार स्तिंभ 1 स्तिंभ 2 प्रकार पुन: सत्यापन अिवध
1. विद्युत ऊर्ाा मीटर – िाट-आिर, ररएवक्टि-िोल्ट-ए्पीयर-आिर, िोल्ट-ए्पीयर-आिर या क्यू- आिर; इनम ें इिंटीग्रेटेड पल्स इवनवशएटर, मल्टी-टैररफ रवर्स्टर, ररमोट-मीटर-रीलडिंग या ऑटोमैरटक- मीटर-रीलडिंग (एएमआर) फीचर िाले मीटर भी शावमल ह।ैं वडस्क-सस्पेंशन प्रकार चुिंबकीय अन्य क) 1- या 1½- एवलमेंट, स्टैंडडा ए या एस बेस 5 िष ा 2 िष ा ख) 2-, 2½- या 3- एवलमेंट 3 िष ा 2 िष ा ग) टोटलाइलज़िंग प्रकार 2 िष ा 2 िष ा
2. लॉस मीटर क) A²-आिर 2 िष ा ख) V²-आिर 2 िष ा
3. विद्यतु मािंग (शवक्त) मीटर – िाट, ररएवक्टि-िोल्ट-ए्पीयर या िोल्ट-ए्पीयर वर्समें एकीकृत ऊर्ाा मीटर और सिंबिंवधत फिंक्शन िाले उपस्करभी शावमल ह ैं क) यािंवत्रक ब्लॉक-अिंतराल 2 िष ा ख) ऊष्मीय या रेक्टी-ऊष्मीय 2 िष ा
4. अन्य मीटर क) मैग्नेरटक-टेप पल्स-ररकॉडार 3 िष ा ख) पिंच-पेपर पल्स-ररकॉडार 3 िष ा ग) इलेक्ट्ॉवनक पल्स-ररकॉडार 2 िष ा74 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] घ) थमाल कन्िटार 3 िष ा ङ) ट्ािंसड्यूसर 3 िष ा च) इलेक्ट्ॉवनक इिंस्ूमेंट ट्ािंसफॉमार 3 िष ा सारणी ख इलेक्ट्ॉवनक-प्रकार स्तिंभ I स्तिंभ II प्रकार पुन: सत्यापन अिवध
5. विद्यतु ऊर्ाा काय ा – िाट-आिर, ररएवक्टि-िोल्ट-ए्पीयर-आिर, िोल्ट-ए्पीयर-आिर, क्यू- आिर, A²आिर, V²आिर; वर्सके अिंतगात इिंटीग्रेटेड पल्स इवनवशएटर और/या ररसीिर, मल्टी-टैररफ रवर्स्टर, ररमोट-मीटर-रीलडिंग या ऑटोमैरटक-मीटर-रीलडिंग (एएमआर) फीचर िाले मीटर भी ह।ैं क) लसिंगल-फेज़ प्रकार 3 िष ा ख) पॉलीफेज़ प्रकार 3 िष ा
6. विद्यतु मािंग (शवक्त) काया – िाट, ररएवक्टि-िोल्ट-ए्पीयर या िोल्ट-ए्पीयर, एकीकृत ऊर्ाा मीटर और सहयुक्त फिंक्शन िाले उपकरण भी ह ैं क) लसिंगल-फेज़ प्रकार 3 िष ा ख) पॉलीफेज़ प्रकार 3 िष ा
(2) परीक्षण
(i) अिंशािंकन वस्थवत - सुवनवित करें क्रक उपयोग की र्ा रही परीक्षण प्रणाली में मीटरों को सत्यावपत करने के वलए पयााप्त सटीकता ह,ै और अिंशािंकन विवधमान्य ह।ै
(ii) अनुरूपता र्ाँच - सुवनवित करें क्रक उपस्करप्रकार अनुमोदन दस्तािेज़ों के अनुरूप विवनर्मात ह।ै
(iii) िामा-अप - पूणा प्रचालन से पहले मीटर को िामा-अप करना आिश्यक हो सकता ह।ै िामा-अप की अिवध उपस्करके िास्तविक प्रकार पर वनभार करती ह ैऔर इसे पहल ेसे अिचाररत क्रकया र्ाएगा। प्रारिंवभक आिंतररक त्रुरट परीक्षण के समय, विवनमााता द्वारा तय की गई 5 वमनट से कम की अिवध तक, हर करिंट स्तर पर माप लने े स े पहले मीटर को वस्थर होने का समय क्रदया र्ाएगा। परीक्षण लबिंदओंु का िम न्यूनतम करिंट से अवधकतम करिंट और क्रफर अवधकतम करिंट से न्यूनतम करिंट तक होगा। प्रत्येक परीक्षण लबिंद ु के वलए, पररणामी त्रुरट इन मापों का औसत होगी। I , के वलए, अवधकतम माप समय max 10 वमनट होगा, वर्समें वस्थरीकरण का समय भी शावमल ह।ै[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 75
(iv) न्यूनतम परीक्षण कायािम - न्यूनतम कायािम में सव्मवलत ह:ैं • वबना-भार के र्ािंच; • प्रारिंवभक करिंट की र्ािंच; • करिंट वनभरा ता; • रवर्स्टर की र्ाँच। (क) वबना- भार के र्ािंच - इस परीक्षण के वलए, करिंट सर्काट में कोई करिंट नहीं होगा। परीक्षण U पर क्रकया र्ाएगा। nom वर्न मीटरों में टेस्ट आउटपुट होता है, उनका आउटपुट एक से अवधक पल्स उत्पन्न नहीं करेगा। इलेक्ट्ोमैकेवनकल मीटर के वलए, मीटर का रोटर एक पूरा चक्कर नहीं लगाएगा। न्यूनतम परीक्षण अिवध ∆t, 6(2)(iv) में यथा विवनर्दाष्ट अिवध होगी। एक से अवधक कनेक्शन मोड िाले मीटर का परीक्षण सभी मोड में क्रकया र्ाना चावहए। तथावप , यक्रद परीक्षण स्थावपत मीटर पर इन-वसटू क्रकया र्ाता है, तो केिल िास्तविक कनेक्शन मोड का परीक्षण करना आिश्यक ह।ै प्राथवमक रेटेड रवर्स्टर िाले ट्ािंसफॉमार- प्रचावलत मीटरों के वलए, र्हाँ k (और सिंभितःU ) का मान प्राथवमक साइड nom के मान के तौर पर क्रदया गया होता है, िहाँ k (और U ) के मान को वद्वतीयक साइड के मान (िोल्टेर् और करिंट) के nom अनुसार पुनगावणत क्रकया र्ाना चावहए। (ख) प्रारिंवभक करिंट की र्ािंच – परीक्षण I और यूवनटी ऊर्ाा घटक पर क्रकया र्ाता ह।ै st लगातार प्रक्रिया से उत्पाक्रदत बड़ी सिंख्या में समान मीटरों के प्रारिंवभक सत्यापन के वलए, हर 3 मास में क्रकसी विशेष मीटर प्रकार के नमनू ा बैच पर I से I तक के त्रुरट िि को ररकॉडा करना पयााप्त ह।ै st min अन्य साधनो द्वारा वनर्मात मीटरों के प्रारिंवभक सत्यापन के वलए, यह देखना पयााप्त होगा क्रक शुरुआती करिंट लागू करन े पर मीटर लगातार चलता रह े (6(2)(iii) में परीक्षण प्रक्रिया देखें)। एक स े अवधक कनेक्शन मोड िाले मीटर का परीक्षण सभी मोड में क्रकया र्ाना चावहए। तथावप, यक्रद परीक्षण स्थावपत मीटर पर इन-वसटू क्रकया र्ाता है, तो केिल िास्तविक कनेक्शन मोड का परीक्षण करना आिश्यक ह।ै (ग) करिंट वनभारता - मीटरों को सारणी 2 की सटीकता अपेक्षाओं का अनुपालन करना होगा। न्यूनतम रूप से, इनकी र्ाँच वनम्नवलवखत करिंट पर की र्ानी चावहए:
• I , PF = 1; min • I , PF = 1; tr • I , PF = 0.5 इिंडवक्टि; tr • 10 I , PF = 1; tr • 10 I , PF = 0.5 इिंडवक्टि; tr • I , PF = 1; max • I , PF = 0.5 इिंडवक्टि max76 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] िैकवल्पक लसिंगल-फेज़ कनेक्शन मोड िाले या टू-फेज़ मीटर के रूप में उपयोग क्रकए र्ा रह े थ्री-फेज़ मीटरों के मामल े में, प्रत्येक फेज़ के वलए लसिंगल-फेज़ लोड पररक्षण वनम्नवलवखत पर अलग-अलग क्रकया र्ाएगा:
• 10 I , PF = 1; और tr • 10 I , PF = 0.5 इिंडवक्टि. tr वर्न मीटरों में कनेक्शन के िकै वल्पक तरीके होते ह,ैं र्ैस े क्रक पॉली-फेज़ मीटर के वलए िन-फेज़ कनेक्शन या टू-फेज़ मीटर के रूप में उपयोग क्रकए र्ाने िाले मीटर, उनके वलए यह परीक्षण प्रत्येक कनेक्शन मोड के वलए अलग-अलग क्रकया र्ाएगा। (घ) रवर्स्टर की र्ाचँ - यक्रद सटीकता अपेक्षाओं के परीक्षण के वलए टेस्ट (पल्स) आउटपुट का उपयोग क्रकया र्ाता ह,ै तो यह सुवनवित करन े के वलए एक परीक्षण क्रकया र्ाना चावहए क्रक बेवसक एनर्ी रवर्स्टर और सुसिंगत टेस्ट आउटपुट के बीच का सिंबिंध विवनमााता द्वारा विवनर्दाष्ट सिंबिंध के अनुरूप ह।ै परीक्षण को मीटर के माध्यम से E ऊर्ाा की मात्रा गुर्ार कर क्रकया र्ाएगा, र्हाँ E ≥E हो, र्ैसा क्रक 6(2)(v) में min विवनर्दाष्ट ह:ै मीटर से गुज़री ऊर्ाा की गणना परीक्षण आउटपुट से प्राप्त पल्स की सिंख्या का उपयोग करके की र्ाएगी; इस ऊर्ा ा और रवर्स्ट्ीकृत की गई ऊर्ाा के बीच के सापेक्ष अतिं र को अिधाररत क्रकया र्ाएगा। यह सापेक्ष अिंतर, आधार अवधकतम स अनुज्ञेय त्रुरट के दसिें भाग स े अवधक नहीं होना चावहए। परीक्षण एक एकल आर्बाट्ेरी करिंट I ≥I पर क्रकया र्ाएगा। tr
(v) सीललिंग - अगर मीटर पर सील नहीं लगी ह ै(र्ैसे क्रक अभी तक सील नहीं लगाई गई ह ैया सत्यापन परीक्षण के दौरान हटा दी गई ह)ै , तो मीटर को सील क्रकया र्ाएगा।
(3) प्रयोगशाला में शुरुआती और पिातिती के सत्यापन के वलए सिंदभा वस्थवतयािं - प्रयोगशाला में शुरुआती और पिातिती के सत्यापन के वलए सिंदभा वस्थवतयाँ और भार वस्थवतया ँ सारणी 16 और 17 में दी गई ह।ैं सारणी 16 शुरुआती और पिातिती के सत्यापन के वलए सिंदभा वस्थवतयािं और उनकी सहनशीलताए िं मात्रा सिंदभा वस्थवतया िं सहनशीलता िोल्टेर् Unom ± 2 % पररिेश का तापमान 23 ºC ± 5 ºC आिृवत्त Fnom ± 0.5 % िेि-फॉमा Sinusoidal d ≤ 2% रेफरेंस आिृवत्त पर बाहरी मूल 0 T B ≤ 0.1 mT का चुिंबकीय प्रेरण[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 77 इलेक्ट्ोमैग्नेरटक आरएफ फील्ड 0 V/m < 2 V/m 30 kHz – 6 GHz वस्थवत के प्रवत सिंिेदनशील विवनमााता के बताए अनुसार ± 3.0º उपकरणों के वलए सिंचालन की माउिंटटिंग वस्थवत पॉली-फेज़ मीटर के वलए फेज़ एल1, एल2, एल3 अनुिम सभी करिंट सर्काट में समान ± 5 % and ± 5º भार सतिं ुलन करिंट सारणी 17 शुरुआती और पिातिती के सत्यापन के वलए परीक्षणों म ें भार की वस्थवतया ँ और उनकी सहनशीलताए िं श्रेणी क, ख: ± 10 % करिंट परीक्षणाधीन उपस्करकी करिंट सीमा श्रेणी ग, घ: ± 10 % करिंट और िोल्टेर् के बीच फेज़ का परीक्षणाधीन उपस्करकी ऊर्ाा घटक विधुत घटक सीमा अिंतर ± 5º ‘उपाबिंध - क’ सिंयुक्त त्रुरटयों का प्रोक्कलन (र्ानकारीपूणा)
(1) इस अवधसूचना की अपेक्षाओं के आधार पर सिंयुक्त अवधकतम अनुज्ञेय त्रुरट का अनमु ान इस अवधसूचना में आधार अवधकतम अनुज्ञेय त्रुरट के साथ-साथ प्रभाि मात्राओं के कारण होने िाली त्रुरट में बदलाि की अनुज्ञा दी गई ह।ै इसवलए, उपयोग में आने पर अनुपालन करन े िाले मीटर की िास्तविक त्रुरट आधार अवधकतम अनुज्ञये त्रुरट से अवधक हो सकती ह।ै एक समग्र अवधकतम अनुज्ञेय त्रुरट का अनुमान लगान े की आिश्यकता ह,ै र्ो इस अवधसूचना का अनुपालन करने िाल े मीटर प्रकार के वलए उवचत रूप से सबस े बड़ी त्रुरट को इिंवगत करती ह।ै इसम ें रेटेड पररचालन वस्थवतयों के भीतर एक आर्बट्ा ेरी मीटर के माप की त्रुरटयों का अनुमान लगाना शावमल ह।ै78 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] तथावप, आधार अवधकतम अनुज्ञेय त्रुरट और सभी त्रुरट बदलािों को बीर्गवणतीय रूप से र्ोड़न े स े मीटटरिंग अवनवितता का बहुत अवधक वनराशािादी अनुमान वमलेगा, इसके दो कारण ह।ैं प्रभाि कारकों मान के क्रकसी भी यादवृ छछक सेट के वलए, कुछ त्रुरट बदलाि कम होंगे और कुछ के सिंकेत शायद विपरीत होंगे, र्ो एक-दसू रे को रद्द कर देंगे। इसके अलािा, विद्युत मीटर एक एकीकृत उपस्करहै, अतः प्रभाि मात्राओं के कारण होने िाली त्रुरटयािं समय के साथ प्रभाि कारकों के मान बदलने पर कुछ हद तक औसत हो र्ाएिंगी। यक्रद हम वनम्नवलवखत उपधाराए करें:
क) एकीकरण प्रभाि को नज़रअदिं ाज़ क्रकया र्ा सकता है, ख) असर डालने िाले कारकों का कोई भी प्रभाि आपस में र्ड़ु ा हुआ नहीं है; ग) प्रभाि डालने िाली मात्राओं का मान, रेटेड पररचालन वस्थवतयों की सीमाओं की तुलना में सिंदभा मानों के करीब होन े की अवधक सिंभािना ह।ै , घ) प्रभावित करने िाली मात्राओं और कारकों के प्रभािों को गॉवसयन वडवस्ट्ब्यूशन माना र्ा सकता है, और अतः मानक अवनवितता के वलए अवधकतम स्िीकाया त्रुरट बदलाि के आधे मान का उपयोग क्रकया र्ा सकता है, तो कुल अवधकतम अनुज्ञेय त्ररु ट (किरेर् घटक दो मानकर, र्ो लगभग 95% किरेर् सिंभािना के बराबर ह)ै का अनुमान सूत्र(1) का उपयोग करके लगाया र्ा सकता ह:ै v =2* र्हािं Vbase आधार अवधकतम अनुज्ञेय त्रुरट ह;ै Vvoltage िोल्टेर् में वभन्नता के वलए अनुज्ञात अवधकतम त्रुरट बदलाि ह;ै Vfrequency आिृवत्त में वभन्नता के वलए अनुज्ञात अवधकतम त्रुरट बदलाि ह;ै Vunbalance असिंतुलन वभन्नता में बदलाि के वलए अनज्ञु ात अवधकतम त्रुरट बदलाि ह;ै Vharmonics हामोवनक किंटेंट में वभन्नता के वलए अनुज्ञात अवधकतम त्रुरट बदलाि ह;ै Vtemperature तापमान में वभन्नता के वलए अनुज्ञात अवधकतम त्रुरट बदलाि ह।ै
(2) प्रकार परीक्षण के पररणामों और विवशष्ट वस्थवतयों के आधार पर सिंयुक्त त्रुरट का अनमु ान
(i) पद्वत 1 प्रकार परीक्षण के पररणामों का उपयोग करके क्रकसी विशेष मीटर प्रकार के वलए सयिं ुक्त अवधकतम त्रुरट प्राक्कवलत भी लगाया की सकती ह।ै प्रकार परीक्षण के पररणाम अक्सर इस अवधसूचना द्वारा अपेवक्षत वभन्नता से कम वभन्नता दशााते हैं, वर्ससे समग्र अवधकतम त्रुरट के वलए कम मान सुवनवित होता ह।ै[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 79 गॉवसयन वडवस्ट्ब्यूशन की धारणा को सही मानते हुए, परीक्षण पररणामों के सिंयोर्न से कुल अवधकतम त्रुरट सूत्र (3) का उपयोग करके प्राक्कवलत की र्ा सकती ह:ै र्हािं:
हर करिंट I और हर ऊर्ाा घटक PF के वलए i p • e(PF , I ) मीटर की िह आिंतररक त्रुरट ह ै वर्से परीक्षणों के दौरान, करिंट I और ऊर्ाा घटक PF पर मापा P i i p र्ाता ह;ै • δe (T ) , δe (U ) , δe ( f ) परीक्षण के दौरान मापी गई अवधकतम अवतररक्त त्रुरटयाँ ह,ैं p,i p,i p,i र्ब करिंट I और ऊर्ाा घटक PF पर रेटेड पररचालन वस्थवतयों में विवनर्दाष्ट पूरी सीमा में तापमान, िोल्टेर् और i p आिृवत्त को िमशः बदला र्ाता ह ै
(ii) पद्वत 2 र्ब यह माना र्ाए क्रक गॉवसयन वडवस्ट्ब्यूशन अब विवध नहीं है, तो प्रभाि डालने िाले कारकों के असर के वलए रेक्टेंगुलर वडवस्ट्ब्यूशन को आधार मानना चावहए। अतः, सूत्र (3) का उपयोग करके परीक्षण पररणामों के सिंयोर्न से सिंयुक्त अवधकतम त्रुरट प्राक्कवलत की र्ा सकती ह:ै e =2* c र्हािं:
e आधार अवधकतम त्रुरट परीक्षण में प्राप्त अवधकतम त्रुरट ह,ै वर्समें प्रकार परीक्षण(2) की माप अवनवितता को ध्यान base में रखा गया ह;ै e िोल्टेर् वभन्नता परीक्षण में प्राप्त अवधकतम त्रुरट वशफ्ट है, वर्समें प्रकार परीक्षण की माप अवनवितता को ध्यान voltage में रखा गया ह;ै e आिृवत्त वभन्नता परीक्षण में प्राप्त अवधकतम त्रुरट वशफ्ट ह,ै वर्समें प्रकार परीक्षण की माप अवनवितता को ध्यान frequncy में रखा गया ह;ै e असतिं ुलन वभन्नता परीक्षण में प्राप्त अवधकतम त्रुरट वशफ्ट है, वर्समें प्रकार परीक्षण की माप अवनवितता को unbalance ध्यान में रखा गया ह;ै80 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] e हामोवनक वभन्नता परीक्षण म ें प्राप्त अवधकतम त्रुरट वशफ्ट है, वर्सम ें प्रकार परीक्षण की माप अवनवितता को harmonics ध्यान में रखा गया ह;ै e तापमान वभन्नता परीक्षण में प्राप्त अवधकतम त्रुरट वशफ्ट है, वर्समें प्रकार परीक्षण की माप अवनवितता को temperature ध्यान में रखा गया ह।ै रटप्पण (2): कुल त्रुरट के हर घटक e में माप की अवनवितता को शावमल क्रकया र्ाना चावहए। चूिंक्रक एक पद का मान i ज्ञात ह ै और दसू रा अवनवित है, इसवलए उन्ह ें दो असिंबिंवधत सािंवख्यकीय वितरणों के रूप में नहीं माना र्ा सकता; अतः उन्ह ें बीर्गवणतीय रूप से र्ोड़ा र्ाना चावहए। रटप्पण (3): सिंयुक्त त्रुरट में योगदान देने िाले घटकों को चुना र्ा सकता ह ै और उनमें कम से कम ये सव्मवलत होने चावहए: e , e , e और e .
base frequency temperature voltage उपरोक्त गणनाओं में भार पार्श्ावचत्र और पररिेशी तापमान वभन्नता के बीच सहसिंबिंधों के मीटर सटीकता पर पड़ने िाल े प्रभािों को सव्मवलत नहीं क्रकया गया है, क्रकन्तु उपयुक्त वस्थवतयों में इन्ह ें मॉडल क्रकया र्ा सकता ह।ै[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 81 ‘उपाबिंध - ख’ विधायी मामले (सूचना हते ु)
(1) यह अवधसूचना कई शतों के वलए विकल्प प्रदान करके लचीलेपन और एकरूपता के बीच उवचत सिंतुलन बनाती है, र्ैसे क्रक: क) नाममात्र िोल्टेर्; ख) नाममात्र आिृवत्त; ग) वनधााररत तापमान; घ) र्ल और नमी से सरु क्षा का स्तर;
ङ) आिेग िोल्टेर् से सुरक्षा का स्तर; च) ऊर्ाा प्रिाह की क्रदशा को सभिं ालना। ध्यान दें क्रक इसमें ऐसे विषयो से सिंबवन्धत विवनर्दाष्ट अपेक्षाएिं भी सव्मवलत हो सकेंगी र्ैसे: छ) विद्युत इिंटरफेस; र्) यािंवत्रक इिंटरफेस और आिरण। यह भी ध्यान देने योग्य ह ै क्रक, यद्यवप अवधकतम करिंट अक्सर इिंस्टॉलेशन की विशेषताओं द्वारा विवनर्दाष्ट क्रकया र्ाता है, ट्ािंवज़शनल करिंट का मान और/या अवधकतम करिंट और ट्ािंवज़शनल करिंट के बीच का अनुपात कम विधुत उपयोग िाले अिंवतम ग्राहकों के वलए महत्िपूणा है, क्योंक्रक यक्रद लोड करिंट अवधकािंश समय ट्ािंवज़शनल करिंट से कम रहता है, तो इन ग्राहकों को बड़ी सापेक्ष मीटटरिंग त्रुरटयों का सामना करना पड़ सकता ह।ै I and I के मान तावलका 18 स े चुने र्ा tr max सकते ह।ैं सारणी 18 िािंवछत करिंट सीमाएिं I और I के िािंवछत मान I और I के अन्य मान tr max tr max (ए्पीयर) (ए्पीयर) मीटर कनेक्शन का प्रकार मानक I मान: 0.125, 0.25, 0.5, अन्य I मान: 0.75, 1.5, 2.5, tr tr सीधा कनेक्शन 1, 2, 3. 4, 5 मानक I मान: 10, 20, 40, 60, 80, अन्य I मान:30, 50, 160 max max 100, 120, 200, 32082 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] करिंट ट्ािंसफॉमार के माध्यम से कनेक्शन मानक I मान: 0.05, 0.1, 0.25 अन्य I मान: 0.125 tr tr मानक I मान: 1.2, 1.5, 2, 2.4, 3, 4, max 6, 7.5, 10, 20 अन्य I मान 3.75, 5 max रटप्पण 1: ट्ािंसफॉमार से प्रचावलत मीटरों की मौर्ूदा रेंर्, करिंट ट्ािंसफॉमार की मौर्ूदा रेंर् के अनुकूल होनी चावहए। रटप्पण 2: अवधसूचना अवधकतम अनुज्ञेय I न्यूनतम करिंट रेंर् या I और I बीच न्यूनतम अनुपात विवहत करती ह।ै tr max tr इन्ह ें पूणा मानों या कुछ प्रकार के ग्राहकों आक्रद की विवशष्ट विद्युत मािंग पर आधाररत मानों के रूप में विवहत व त क्रकया र्ा सकता ह।ै
(i) सटीकता िगा का चयन विधुत के बड़े प्रिाह को मापते समय अवधक सटीक मीटरों का उपयोग क्रकया र्ाना चावहए, ताक्रक माप की अपररहाय ा त्रुरटयों के आर्थाक प्रभाि को कम क्रकया र्ा सके। र्हाँ ऊर्ाा का उपभोग कम हो, िहा ँ िगा क मीटर स्िीकाया हो सकते हैं, क्रकन्तु उच्च ऊर्ाा उपभोग िाले मामलों में उच्च िगा इिंडेक्स िाले मीटरों का उपयोग क्रकया र्ाना चावहए। अवधकािंश मीटर कनेक्शन मोड के वलए मीटर की सटीकता पािर वग्रड की विशेषताओं से स्ितिंत्र होगी; तथावप, वग्रड की विशेषताओं के प्रभाि का मूल्यािंकन करने की आिश्यकता हो सकती है, विशेष रूप स ेउच्च िगा इिंडेक्स िाल ेमीटरों के वलए, उन मामलों में र्हाँ वग्रड की समरूपता और/या लीकेर् करिंट की कमी की अिंतर्नावहत धारणाएँ हों। यह सिंभि ह ै क्रक ऐसी वस्थवतयों में वग्रड की विशेषताओं के कारण कुल मीटर त्रुरट, स्ियिं मीटर की त्रुरट से अवधक हो, विशेष रूप से उच्च सटीकता पर; इसवलए, इस प्रकार के कनेक्शन मोड के उपयोग को सीवमत करना उवचत हो सकता है।
(ii) इस अवधसूचना के अधीन सव्मवलत न क्रकए गए विषय यह अवधसूचना केिल विधुत मीटर की सुसिंगत मापविज्ञान अपेक्षाओं का िणान करने तक सीवमत ह ै और इसवलए इसमें कुछ मामले सव्मवलत नहीं ह,ैं र्ैस े क्रक: क) ईएमसी उत्सर्ान;
ख) विधुत से सरु क्षा और व्यवक्तगत सुरक्षा; ग) सिंचार प्रोटोकॉल की सरु क्षा और माप पररणामों का आगे का प्रबिंधन।[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 83 ‘उपाबिंध – ग’: चयवनत सत्यापन पद्वतयो का वििरण 1 दस्तािेज़ीकरण और विवनदेश का विश्लेषण और वडज़ाइन का सत्यापन (एडी) अनुप्रयोग:
मूल प्रक्रिया, र्ो सभी सॉफ़्टिेयर सत्यापन वनधाारण के दौरान लागू होगी। पूिा-शतें: यह प्रक्रिया मापन यिंत्र के विवनमााता के दस्तािेज़ों पर आधाररत ह।ै आिश्यकताओं के अनसु ार, इस दस्तािेज़ का दायरा पयााप्त होना चावहए:
(1) उपस्करके बाहरी रूप से सलु भ कायों का सामान्य प्ररूप (उन सरल उपकरणों के वलए उपयुक्त वर्नमें वडस्प्ले के अलािा कोई इिंटरफेस नहीं होता, सभी सुविधाओं को कायाात्मक परीक्षण द्वारा सत्यावपत क्रकया र्ा सकता ह ै और वर्नमें कपट का र्ोवखम कम होता है);
(2) सॉफ़्टिेयर कायों और इिंटरफेस का विवनदेश (उन उपकरणों के वलए आिश्यक वर्नमें इिंटरफेस हों, उन उपस्करकायों के वलए वर्नका कायाात्मक रूप से परीक्षण नहीं क्रकया र्ा सकता ह ैऔर कपट के बढे हुए र्ोवखम के मामले में)। वििरण में उन सभी सॉफ़्टिेयर कायों को स्पष्ट और व्याख्यावयत क्रकया र्ाएगा वर्नका मापविज्ञान विशेषताओं पर प्रभाि पड़ सकता ह;ै
(3) इिंटरफेस के सिंबिंध में, दस्तािज़े ीकरण म ें उन कमािंड या वसग्नल की पूरी सूची सव्मवलत होगा वर्न्ह ें सॉफ़्टिेयर समझ सकता ह।ै प्रत्येक कमािंड के प्रभाि का विस्तार से दस्तािेज़ीकरण क्रकया र्ाएगा । वबना दस्तािेज़ िाले कमािंड पर उपस्करक्रकस प्रकार प्रवतक्रिया करता है, इसका िणान क्रकया र्ाना चावहए;
(4) यक्रद सॉफ़्टिेयर के कायों को समझने और उनका मूल्यािंकन करने के वलए आिश्यक हो, तो र्रटल मापन एल्गोररदम, क्रिप्टोग्राक्रफक कायों या महत्िपूणा समय बाधाओं के वलए अवतररक्त दस्तािेज़ प्रदान क्रकए र्ाने चावहए;
(5) र्ब यह स्पष्ट न हो क्रक क्रकसी सॉफ़्टिेयर प्रोग्राम के काया को कैसे सत्यावपत क्रकया र्ाए, तो परीक्षण पद्वत विकवसत करने का दावयत्ि विवनमााता पर होना चावहए। इसके अवतररक्त, प्रश्नों के उत्तर देन े के प्रयोर्न स े प्रोग्रामर की सिे ाएँ परीक्षक को उपलब्ध कराई र्ानी चावहए। परीक्षण के वलए एक सामान्य पूिा-शता यह ह ै क्रक दस्तािज़े ीकरण पूणा हो और ईयूटी की स्पष्ट पहचान हो, अथाात उन सॉफ़्टिेयर पैकेर्ों की र्ो मापविज्ञान कायों में योगदान करते ह।ैं वििरण:
परीक्षक, पाठ्य वििरण और ग्राक्रफकल प्रस्तुवतयों का उपयोग करके मापने िाले उपस्करके कायों और विशेषताओं का मूल्यािंकन करता ह ै और विवनिय करता ह ै क्रक क्या िे अपेक्षाओं का अनुपालन84 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] करते ह।ैं मापविज्ञान अपेक्षाओं के साथ-साथ सॉफ्टिेयर-कायाात्मक अपेक्षाओं (र्ैसे कपट से सुरक्षा, समायोर्न मापदिंडों की सरु क्षा, अननुतात काया, अन्य उपकरणों के साथ सिंचार, सॉफ्टिेयर का अपडेट, दोष का पता लगाना, आक्रद) पर विचार और मूल्यािंकन क्रकया र्ाना चावहए। पररणाम:
यह प्रक्रिया मापने िाले उपस्करकी सभी विशेषताओं के वलए पररणाम देती है, परन्तु विवनमााता द्वारा उवचत दस्तािेज़ प्रस्तुत क्रकए गए हों। इस पररणाम को सॉफ़्टिेयर मूल्यािंकन ररपोटा के सॉफ़्टिेयर स े सिंबिंवधत वहस्स े में प्रेवलवखत क्रकया र्ाना चावहए। पूरक प्रक्रियाएँ:
यक्रद दस्तािेज़ों की र्ािंच से साखान सत्यापन पररणाम नहीं वमलत े ह,ैं तो अवतररक्त प्रक्रियाओं को लाग ू क्रकया र्ाना चावहए। अवधकािंश मामलों में, "कायाात्मक परीक्षण द्वारा मापविज्ञान कायों को सत्यावपत करना" एक पूरक प्रक्रिया ह।ै 2 सॉफ्टिेयर कायों का कायात्ा मक परीक्षण द्वारा सत्यापन (िीएफटीएसडब्ल्यू) अनुप्रयोग:
उदाहरण के वलए, मापदिंडों की सुरक्षा, सॉफ़्टिेयर पहचान का सिंकेत, सॉफ़्टिेयर-आधाररत फॉल्ट वडटेक्शन, वसस्टम (खासकर सॉफ़्टिेयर एनिायरनमेंट) का कॉवन्फगरेशन आक्रद के सत्यापन के वलए। पूिा-शतें: ऑपरेटटिंग मैनुअल, सॉफ़्टिेयर दस्तािेज़ीकरण, काम करने का तरीका, परीक्षण उपस्कर वििरण:
ऑपरेटटिंग मैनुअल, उपस्करदस्तािेज़ या सॉफ़्टिेयर दस्तािेज़ में िर्णात अपेवक्षत विशेषताओं की व्यिहाररक र्ाचँ की र्ाती ह।ै यक्रद सॉफ़्टिेयर वनयिंवत्रत ह ै और सही ढिंग स े काय ा कर रहा है, तो उसे वबना क्रकसी और सॉफ़्टिये र विश्लेषण के मान्य माना र्ाएगा। पररणाम:
सॉफ्टिेयर-वनयिंवत्रत फीचर वर्स पर विचार क्रकया र्ा रहा है, िह ठीक ह ै या नहीं। पूरक प्रक्रियाएँ: सॉफ्टिेयर-वनयिंवत्रत उपस्करकी कुछ विशेषताओं या कायों को यथािर्णात व्यािहाररक रूप स े मान्य नहीं क्रकया र्ा सकता ह।ै यक्रद उपस्करमें इिंटरफेस हैं, तो सामान्यतः केिल यादवृ छछक रूप स े कमािंड की कोवशश द्वारा अप्रावधकृत कमाडिं का पता लगाना सिंभि नहीं ह।ै इसके अवतररक्त, इन कमािं्स को बनान े के वलए एक सेंडर की[भाग II—खण् ड 3(i)] भारत का रार्पत्र : असाधारण 85 आिश्यकता होती ह।ै सामान्य सत्यापन स्तर के वलए, पद्वत.1, वर्समें विवनमााता की घोषणा सव्मवलत ह,ै इस अपेक्षा को पूरा कर सकती ह।ै विस्तृत परीक्षण स्तर के वलए, सी.3 या सी.4 र्ैसे सॉफ़्टिेयर विश्लेषण की आिश्यकता होती ह।ै 3 मापविज्ञान डाटा प्रिाह विश्लषे ण (डीएफए) अनुप्रयोग:
विवधक वनयिंत्रण के अधीन डाटा डोमेन के माध्यम से मापन मानों के डाटा प्रिाह के वनयिंत्रण स े सिंबिंवधत सॉफ़्टिेयर वडज़ाइन का विश्लेषण करने के वलए, वर्समें सॉफ़्टिेयर पृथक्करण की र्ाँच भी सव्मवलत ह।ै वििरण:
इस विश्लेषण का उद्देश्य सॉफ़्टिेयर के उन सभी भागो का पता लगाना ह ै र्ो माप के मानों की गणना में सव्मवलत ह ैंया वर्न पर इसका प्रभाि पड़ सकता ह।ै 4 कोड का वनरीक्षण और समीक्षा (सीआईडब्ल्यूटी) अनुप्रयोग: अगर सॉफ़्टिेयर की क्रकसी विशेषता आिश्यक मानी र्ाती है, तो इस पद्वत से मान्य क्रकया र्ा सकता ह।ै वििरण:
परीक्षक स्रोत कोड के एक-एक असाइनमेंट के माध्यम स े र्ािंच करता ह,ै और कोड के सिंबिंवधत भाग का मूल्यािंकन करता ह ैताक्रक यह अिधाररत क्रकया र्ा सके क्रक अपक्षे ाएिं परू ी हुई ह ैंया नहीं और प्रोग्राम के काया और विशेषताएिं दस्तािेज़ीकरण के अनुरूप ह ैंया नहीं। परीक्षक उन एल्गोररदम या फिंक्शिंस पर भी ध्यान केंक्ररत कर सकता ह ै वर्न्ह ें उसने र्रटल, त्रुरट-प्रिण, अपयााप्त रूप से प्रलेवखत आक्रद के रूप म ें पहचाना है, और विश्लेषण और र्ाँच करके स्रोत कोड के सिंबिंवधत भाग का वनरीक्षण कर सकता ह।ै “ [फा. स.िं I-9/22/2014-डब्ल्यूएम] अनुपम वमश्रा, अपर सवचि रटप्पण:- मलू वनयम भारत के रार्पत्र , असाधारण , भाग II , खिंड 3 उपखण्ड (i) म ेंअवधसूचना सिंख्यािंक सा. का. वन. 71(अ), तारीख 7 फरिरी, 2011 द्वारा प्रकावशत क्रकये गए थे और अवधसूचना सिंख्यािंक सा. का. वन. 568 (अ), तारीख 03 र्ुलाई, 2026 द्वारा अिंवतम बार सिंशोवधत क्रकये गए थ े।86 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] MINISTRY OF CONSUMER AFFAIRS, FOOD AND PUBLIC DISTRIBUTION (Department of Consumer Affairs)
NOTIFICATION New Delhi, the 15th September, 2026 GSR. 809(E).––In exercise of the powers conferred by sub-section (1) read with clauses (c), (f), (h), (i) and (s) of sub-section (2) of section 52 of the Legal Metrology Act 2009, (1 of 2010), the Central Government hereby makes the following rules, namely:-
1. Short title and commencement.– (1) These rules may be called the Legal Metrology
(General) Fifth Amendment Rules, 2026.
(2) They shall come into force after one hundred and eighty days from the date of publication in the Official Gazette.
2. In the Legal Metrology (General) Rules, 2011, in the Eighth Schedule, after Part XIII, the following Part shall be inserted, namely:– “PART XIV ACTIVE ELECTRICAL ENERGY METERS Part 1: Metrological and technical requirements
1. Definitions of meters and their constituents:- (1) Electricity meter.– Instrument intended to measure electrical energy continuously by integrating power with respect to time and to store the result
Explanation: continuously may also cover meters with a sampling rate sufficiently high to fulfill the requirements of this Part;
(2) Interval meter.– means an electricity meter which displays and stores the result as measured in predetermined time intervals;
(3) Prepayment meter.– means an electricity meter intended to allow electrical energy to be delivered up to a predetermined amount Note 1: Such a meter measures energy continuously and stores and displays the measured energy;
(4) Multi-tariff meter, multi-rate meter.– means an electricity meter intended to measure and display electrical energy where energy will have more than one tariff rate
Note: The tariff rate may be determined by time, load or some other quantity;
(5) Direct connected meter.– means meter intended for use by direct connection to the circuit(s) being measured, without the use of external device(s) such as instrument transformer(s);[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 87
(6) Transformer operated meter.– means meter intended for use with one or more external instrument transformers;
(7) Electromechanical meter.– means meter in which currents in fixed coils react with the currents induced in the conducting moving element, generally (a) disk(s), which causes their movement proportional to the energy to be measured;
(8) Static meter.– means a meter in which current and voltage act on solid state (electronic) elements to produce an output proportional to the energy to be measured;
(9) Measuring element.– Part of the meter that transforms a current and a voltage into a signal proportional to the power and/or energy
Note : A measuring element can be based on an electromagnetic, electrical or an electronic principle;
(10) Current circuit.– Internal connections of the meter and part of the measuring element through which flows the current of the circuit to which the meter is connected;
(11) Voltage circuit.– Internal connections of the meter, part of the measuring element and, in the case of static meters, part of the power supply, supplied with the voltage of the circuit to which the meter is connected;
(12) Indicating device (display).– means part of the meter that displays the measurement results either continuously or on demand;
Note: An indicating device may also be used to display other relevant information.
(13) Register.– means part of the meter that stores the measured values.
Note: The register may be an electromechanical device or an electronic device and may be integral to the indicating device;
(14) Primary rated register(For transformer operated meters).– means Register where the scale factor(s) due to the used instrument transformer(s) is considered such that the measured energy on the primary side of the instrument transformer(s) is indicated;
(15) Register multiplier.– means constant with which the register reading shall be multiplied to obtain the value of the metered energy;
(16) Meter constant.– means value expressing the relation between the energy registered by the meter and the corresponding value of the test output;
(17) Test output.– means device which can be used for testing the meter, providing pulses or the means to provide pulses corresponding to the energy measured by the meter;
(18) Adjustment device.– means device or function incorporated in the meter that allows the error curve to be shifted with a view to bringing errors (of indication) within the maximum permissible errors;
(19) Ancillary device.– means device intended to perform a particular function, directly involved in elaborating, transmitting or displaying measurement results88 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)]
Note: An ancillary device is not part of the basic metrology function of a meter; and
(20) Sub-assembly.– means part of a device having a recognizable function of its own.
2. Metrological characteristics:–– The following characteristics are as follows, namely:––
(1) Current (I) .– Value of the electrical current flowing through the meter
Explanation: The term current in this Part indicates r.m.s. (root mean square) values unless otherwise specified.
(2) Starting current (I ) .– Lowest value of current specified by the manufacturer at which st the meter should register electrical energy at unity power factor and, for poly-phase meters, with balanced load.
(3) Minimum current (I ) .– Lowest value of current at which the meter is specified by the min manufacturer to meet the accuracy requirements.
(4) Transitional current (I ) .– Value of current at and above which the meter is specified tr by the manufacturer to lie within the smallest maximum permissible error corresponding to the accuracy class of the meter.
(5) Maximum current (I ) .– Highest value of current at which the meter is specified by max the manufacturer to meet the accuracy requirements.
(6) Voltage (U) .– Value of the electrical voltage supplied to the meter
Note: The term “voltage” in this Part indicates r.m.s. (root mean square) values unless otherwise specified.
(7) Nominal voltage (U ) .– Voltage specified by the manufacturer for normal operation of nom the meter
Note: Meters designed for operation across a range of voltages may have several nominal voltage values.
(8) Frequency (f) .– Frequency of the voltage (and current) supplied to the meter.
(9) Nominal frequency (f ) .– Frequency of the voltage (and current) specified by the nom manufacturer for normal operation of the meter.
(10) Harmonic.– Part of a signal that has a frequency that is an integer multiple of the fundamental frequency of the signal
Note: The fundamental frequency is generally the nominal frequency (f ). nom
(11) Sub-harmonic.– Frequency that is an integer fraction of the fundamental frequency of the signal, that is, 1/n times the fundamental frequency, where n is an integer greater than 1.
(12) Harmonic number.– An integer number used to identify a harmonic
Note : The harmonic number is the ratio of the frequency of a harmonic to the fundamental frequency of the signal.[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 89
(13) Distortion factor (d) .– Ratio of the r.m.s. value of the harmonic content to the r.m.s. value of the fundamental term Note 1: The harmonic content is obtained e.g. by subtracting from a non-sinusoidal alternating quantity its fundamental term.
Note 2: The distortion factor is usually expressed as a percentage. It is equivalent to THD, total harmonic distortion.
(14) Power factor (PF) .– Ratio of the active power to the apparent power
Note: At sinusoidal and either one-phase or symmetrical three-phase conditions, the power factor = cos Φ = the cosine of the phase difference Φ between voltage U and current I.
(15) Active power.– Rate at which energy is transported
Note: In an electrical system active power is measured as the time mean of the instantaneous power, which is calculated at each instant as the product of voltage and current: p(t) =u(t)⋅i(t)
w here: u is the instantaneous voltage, i is the instantaneous current, p is the instantaneous power.
At sinusoidal conditions active power is the product of the r.m.s. values of current and voltage and the cosine of the phase angle between them, calculated for each phase. It is usually
expressed in kW:
P=U ⋅I ⋅ cos Φ. r.m.s r.m.s
(16) Active energy.– Active power integrated over time Note 1: E(T) = =
w here:
E is the active energy. Other symbols are as defined in 2(2)(15) Note 2: Active energy is usually expressed in kWh or MWh. Refer to 3(1) for requirements on units of measurement.
(17) Relative error of indication.– Indication minus reference quantity value, divided by the reference quantity value Note 1: The relative error is usually expressed as a percentage of the reference quantity value.
(18) Maximum permissible error mpe.– Extreme value of measurement error, with respect to a known reference quantity value, permitted by specifications or regulations for a given measurement, measuring instrument or measuring system Note 1: Usually, the term “maximum permissible errors” or “limits of errors” is used where there are two extreme values.
Note 2: The term “tolerance” should not be used to designate “maximum permissible error”90 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] Note 3: In this Part, the maximum permissible error is a combination of the base maximum permissible error and the maximum permissible error shift as described in Annex A.
Note 4 : For the application of this Part, “specifications or regulations” means: the provisions contained in this Part and the terms “measuring instrument” and “measuring system” mean: electricity meter.
(19) Base maximum permissible error mpe.– Extreme value of the error of indication of a meter, permitted by this Notification , when the current and power factor are varied within the intervals given by the rated operating conditions, and when the meter is otherwise operated at reference conditions
Note: In this Part the maximum permissible error is a combination of the base maximum permissible error and the maximum permissible error shift as described in Annex A.
(20) Maximum permissible error shift.– Extreme value of the change in error of indication of a meter, permitted by this Notification, when a single influence factor is taken from its value at reference conditions and varied within the rated operating conditions Note 1: For each influence factor there is one corresponding maximum permissible error shift.
Note 2: In this Notification, the maximum permissible error is a combination of the base maximum permissible error and the maximum permissible error shift as described in Annex A.
(21) Intrinsic error.– Error of a measuring instrument, determined under reference conditions.
(22) Initial intrinsic error.– the intrinsic error of a measuring instrument as determined prior to performance tests and durability evaluations.
(23) Influence quantity.– Quantity that, in a direct measurement, does not affect the quantity that is actually measured, but affects the relation between the indication and the measurement result Note 1: The concept of influence quantity is understood to include values associated with measurement standards, reference materials and reference data upon which the result of a measurement may depend, as well as phenomena such as short-term measuring instrument fluctuations and quantities such as ambient temperature, barometric pressure and humidity.
(24) Influence factor.– Influence quantity having a value which ranges within the rated operating conditions of a measuring instrument
(25) Disturbance.– Influence quantity having a value within the limits specified in this
Notification, but outside the specified rated operating conditions of a measuring instrument
Note: An influence quantity is a disturbance if the rated operating conditions for that influence quantity are not specified.
(26) Rated operating condition.– Operating condition that must be fulfilled during measurement in order that a measuring instrument or measuring system perform as designed[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 91 Note 1: Rated operating conditions generally specify intervals of values for a quantity being measured and for any influence quantity.
Note 2: For the application of this Notification, the terms “measuring instrument” and “measuring system” mean: electricity meter.
(27) Reference condition.– Operating condition prescribed for evaluating the performance of a measuring instrument or measuring system or for comparison of measurement results Note 1: Reference operating conditions specify intervals of values of the measured and of the influence quantities.
Note 2: For the application of this Notification, the terms “measuring instrument” and “measuring system” mean: electricity meter.
(28) Accuracy class.– Class of measuring instruments or measuring systems that meet stated metrological requirements that are intended to keep measurement errors or instrumental measurement uncertainties within specified limits under specified operating conditions
Note: In this Notification, the stated metrological requirements for accuracy class include permissible responses to disturbances.
(29) Durability.– Ability of the measuring instrument to maintain its performance characteristics over a period of use.
(30) Fault.– Difference between the error of indication and the intrinsic error of a measuring instrument Note 1: Principally, a fault is the result of an undesired change of data contained in or flowing through a measuring instrument.
Note 2: From the definition it follows that a "fault" is a numerical value which is expressed either in a unit of measurement or as a relative value, for instance as a percentage.
Note 3: In this Notification, the above definition does not apply to the term ‘earth fault’, in which the word ‘fault’ has its usual dictionary meaning.
(31) Significant fault.– Fault exceeding the applicable fault limit value
Note: The following are also considered to be significant faults: • a change larger than the critical change value (see 3(3)(vi)(b)) has occurred in the measurement registers due to disturbances; • the functionality of the meter has become impaired.
(32) Checking facility.– Facility that is incorporated in a measuring instrument and which enables significant faults to be detected and acted upon92 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] Note 1: “Acted upon” refers to any adequate response by the measuring instrument (luminous signal, acoustic signal, prevention of the measurement process, etc.).
Note 2: For the application of this Notification, the term “measuring instrument” means: electricity meter and the action following the detection of a significant fault should be either to stop measuring and record the time and duration of the stop, or record the time and duration of the fault and the amount of energy measured during the fault.
Note 3: Faults that are detected and acted upon by means of a checking facility shall not be considered as significant faults.
(33) Primary register.– Register that is subject to the requirements of this Notification
(34) Bi-directional (energy) flow.– Capability of the meter to measure energy flow in both directions (positive and negative).
(35) Positive-direction only (energy) flow.– Capability of the meter to measure energy flow in only one direction (positive direction).
(36) Uni-directional (energy) flow.– Capability of the meter to measure energy flow regardless of the direction of energy flow.
(37) Positive (energy) flow.– Direction of energy flow towards the consumer.
(38) Negative (energy) flow (for bi-directional and uni-directional meters) .– Direction of energy flow opposite to positive
Note: For positive-direction only, the opposite direction is termed reverse energy flow [see 2(39)].
(39) Reverse (energy) flow (for positive-direction only meters) .– Direction of flow in the opposite direction to positive.
(40) Legally relevant.– Attribute of a part of a measuring instrument, device or software subject to legal control.
3. Metrological requirements.–– (1) Units of measurement,– The units of measurement for
active electrical energy shall be one of the following units: Wh, kWh, MWh, GWh.
(2) Rated operating conditions.– Rated operating conditions are specified in Table 1.
Table 1 Rated operating conditions Condition or Values, ranges influence quality Frequency f ± 2 % where f is to be specified by the manufacturer. nom nom If the manufacturer specifies more than one nominal frequency, the rated operating conditions shall be the combination of all fnom ± 2 % intervals.
Voltage U ± 10 % where U is to be specified by the manufacturer. nom nom Meters designed to operate across a range of voltages shall have[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 93 applicable U values specified by the manufacturer. If the nom manufacturer specifies more than one nominal voltage the rated operating conditions shall be the combination of all U ± 10 % nom intervals.
Current I to I st max I , I , I and I are to be specified by the manufacturer in max tr min st
accordance with the following:
Direction Accuracy class connected A B C D I /I ≥ 50 ≥ 50 ≥ 50 ≥ 50 max tr I /I ≥ 100 ≥ 125 ≥ 250 ≥ 250 max min I /I ≥ 1000 ≥ 1250 ≥ 150 ≥ 1250 max st Transformer- Accuracy class operated A B C D I /I ≥ 24 ≥ 24 ≥ 24 ≥4 max tr I /I ≥ 60 ≥ 120(1) ≥ 120 ≥ 120 max min I /I ≥ 480 ≥ 600 ≥ 1200 ≥ 1200 max st Note (1): ≥60 for class B transformer operated electromechanical meters.
Power factor From 0.5 inductive to 1 to 0.8 capacitive, except for classes C and D where the operating range is from 0.5 inductive to 1 to 0.5 capacitive.
For bi-directional meters the power factor range limits are valid in both directions.
Temperature From lower temperature limit to upper temperature limit as specified by manufacturer.
The manufacturer shall specify the lower temperature limit from
the values: –55 ºC, –40 ºC, –25 ºC, –10 ºC, +5 ºC.
The manufacturer shall specify the upper temperature limit from
the values: +30 ºC, +40 ºC, +55 ºC, +70 ºC.
Humidity and With respect to humidity, the manufacturer shall specify the
water environment class for which the instrument is intended:
H1: enclosed locations where the instruments are not subjected to condensed water, precipitation, or ice formations, H2: enclosed locations where the instruments may be subjected to condensed water, to water from sources other than rain and to ice formations, H3: open locations with average climatic conditions.
Connection The manufacturer shall specify whether the meter is intended for modes direct connection, connection through current transformers or through current and voltage transformers.
The manufacturer shall specify the connection mode(s), the number of measurement elements of the meter and the number of phases of the electric system for which the meter is intended.
A meter in accordance with this Notification may be (but is not94 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] limited to) one or more of the following:
Description single-phase two-wire, 1 element single-phase three-wire, 1 element (applicable only for balanced and symmetrical voltages single-phase three-wire, 2-element three-phase four-wire 3-element three-phase three-wire 2-element (applicable only in cases where leakage currents can be ruled out) two-phase three-wire 2-element (intended for operation on two phases of a three-phase service. Can also be a three- phase meter operated as two-phase three-wire) The manufacturer may specify alternative connection modes for poly-phase meters. These alternative connection mode(s) shall also be part(s) of the operating conditions.
Tilt Mounting position as specified by the manufacturer ± 3 degrees.
If no mounting position is given, any mounting position is allowed.
Harmonics The voltage and current shall be allowed to deviate from the sinusoidal form, as given by the requirements in 3(3)(v), Table 4 “Harmonics in voltage and current circuits”.
Load balance The load balance shall be allowed to vary from fully balanced conditions to current in only one current circuit for poly-phase meters and for single-phase 3-wire meters.
Note: Certain values for various rated operating conditions are specified (See Annex B).
(3) Accuracy requirements.–
(i) General.– The manufacturer shall specify the accuracy class of the meter to be one of A, B, C or D.
Note: Class B is the lowest accuracy class allowed for large consumers, i.e. where consumption exceeds 5000 kWh/year.
The meter shall be designed and manufactured such that its error does not exceed the maximum permissible error for the specified class under rated operating conditions.
The meter shall be designed and manufactured such that, when exposed to disturbances, significant faults do not occur.
A fault is not considered a significant fault if it is detected and acted upon by means of a checking facility. The meter shall clearly indicate if such an event has occurred [2(31) and 2(32)].
Note: The indication could take the form of a light flashing in the event of a fault.
(ii) Direction of energy flow.– Where a manufacturer has specified that a meter shall be capable of bidirectional energy flow, the meter shall correctly handle both positive and negative mean energy flow and the meter shall fulfil the requirement of this Notification for energy flow in both directions. The polarity of energy flow shall be defined by the manufacturer’s connection instructions for the meter. Mean energy flow refers to the active power integrated over at least[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 95 one cycle of the nominal frequency.
A meter shall fall into at least one of the following categories: • single-register, bi-directional, where the meter is specified as capable of measuring both positive and negative mean energy flow, and where the net result will be placed in a single register;
• two-register, bi-directional, where the meter is specified as capable of measuring both positive and negative mean energy flow, as defined by the connection of the meter, and where the positive result and negative result are placed in different registers;
• single-register, positive direction only, where the meter is specified as capable of measuring and registering only positive mean energy flow. It may inherently, by its design, register only positive mean energy flow or it may be equipped with a reverse running detent;
• single-register, uni-directional, where the meter is specified as capable of measuring and registering the absolute value of the mean energy flow. Normally such a meter will register all energy as consumed energy independent of the true direction of the energy flow or of how the meter is connected.
For bi-directional meters, energy registration shall occur in the correct register when the direction of flow changes.
Note 1: The terms “single-register” and “two-register” in the list above refer to the basic energy register(s) only. A meter may have other registers, e.g. for storage of tariff and/or phase information.
Note 2: If necessary, Director (Legal Metrology) in consultation with Central Electricity Authority or any other organization authorised by Government may determine what meter types and calculation methods are appropriate.
(iii) Base maximum permissible errors.– The intrinsic error (expressed in percent) shall be within the base maximum permissible error stated in Table 2 when the current and power factor are varied within the limits given by Table 2 (operating range), and when the meter is otherwise operated at reference conditions.
Table 2 Base maximum permissible errors and no load requirements Quantity Base maximum permissible errors (%) for meters class Current I Power Factor A B C D I ≤I ≤I Unity ± 2.0 ± 1.0 ± 0.5 ± 0.2 tr max
0.5 inductive to 1 to ± 2.5 ± 1.5 ± 0.6 ± 0.3
0.8 capacitive (1) I ≤I < I Unity ± 2.5 ± 1.5 ± 1.0 ± 0.4 min tr
0.5 inductive to 1 to ± 2.5 ± 1.8 ± 1.0 ± 0.5
0.8 capacitive I ≤I < I Unity ± 2.5·I /I ± 1.5·I /I ± 1.0·I /I ± 0.4·I /I st min min min min min
(1) The power factor requirement is from 0.5 inductive to 1 to 0.5 capacitive96 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)]
Note: The combined maximum permissible error (CMPE) and the combined maximum error
(CME) resulting from the type evaluation can be calculated as presented in Annex A (1) and Annex A (2).
(iv) No load.– No significant energy shall be registered under conditions of no load (refer to clause 6(2)(iv) for the test procedure).
Note: The meter is always allowed to stop for currents below I . st
(v) Allowed effects of influence quantities.– The temperature coefficient of the meter shall fulfill the requirements of Table 3 when the meter is otherwise operated at reference conditions.
Table 3 Limits for temperature coefficient of error Influence quantity Power factorL imits for temperature coefficient (%/K) for meters of class A B C D (1) Temperature coefficient 1 ± 0.1 ± 0.05 ± 0.03 ± 0.01 (%/K), over any interval, 0.5 ± 0.15 ± 0.07 ± 0.05 ± 0.02 within the temperature range, inductive which is not less than 15K and not greater than 23K, for current I ≤I ≤I tr max
(1) These values are doubled below –10 °C.
When the load current and power factor are held constant at a point within the rated operating range with the meter otherwise operated at reference conditions, and when any single influence quantity is varied from its value at reference conditions to its extreme values defined in Table 4, the variation of error shall be such that the additional percentage error is within the corresponding limit of error shift stated in Table 4. The meter shall continue to function after the completion of each of these tests.
Table 4 Limit of error shift due to influence quantities Influence quantity Value Test clause Value of Power factor Limit of error shift (%) for meters of current class A B C D Self-heating Continuous current at 6(2)(ii) I 1; 0.5 ± 1 ± 0.5 ± 0.25 ± 0.1 max Imax inductive Load balance(1) Current in only one 6(3)(iii) I ≤I ≤ Imax 1 ± 1.5(2) ± 1.0 ± 0.7 ± 0.3 tr current circuit 0.5 inductive ± 2.5(2) ± 1.5 ± 1 ± 0.5 Voltage variation(3) U ±10 % 6(3)(iv) I ≤I ≤ Imax 1 ± 1.0(9) ± 0.7 ± 0.2 ± 0.1 nom tr
0.5 inductive ± 1.5 ± 1.0 ± 0.4 ± 0.2 Frequency variation f ±2 % 6(3)(v) I ≤I ≤ Imax 1 ± 0.8 ± 0.5 ± 0.2 ± 0.1 nom tr
0.5 inductive ± 1.0 ± 0.7 ± 0.2 ± 0.1 Harmonics in voltage and d is 0 – 40 % I, 0 – 5 % 6(3)(vi) I ≤I ≤ Imax 1 ± 1.0(5) ± 0.6 ± 0.3 ± 0.2 tr current circuits U (4) Tilt ≤ 3 degrees 6(3)(vii) I ≤I ≤ Imax 1 ± 1.5 ± 0.5 ± 0.4 n/a tr Severe voltage variations 0.8 U ≤U < 0.9 U ; 6(3)(viii) 10 I 1 ± 1.0(15) ± 1 ± 0.6 ± 0.3 nom nom tr
1.1 U < U ≤1.15 U nom nom U < 0.8 U +10 to –100 nom One or two phases One or two phases 6(3)(ix) 10 I 1 ± 4 ± 2 ± 1 ± 0.5 tr interrupted (6) Removed Sub-harmonics in the AC Current signal of equal 6(3)(x) 10 I 1 ± 3 ± 1.5 ± 0.75 ± 0.5 tr current circuit power with sub- harmonics present Harmonics in the AC Phase-fired at 6(3)(xi) 10 I 1 ± 1 ± 0.8 ± 0.5 ± 0.4 tr current circuit 90 degrees[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 97 Reversed phase sequence Any two phases 6(3)(xii) 10 I 1 ± 1.5 ± 1.5 ± 0.1 ± 0.05 tr interchanged Continuous (DC) 200 mT at 30 mm from 6(3)(xiii) 10 I 1 ± 3 ± 1.5 ± 0.75 ± 0.5 tr magnetic induction of core surface (10) external origin (10) Magnetic field (AC, 400 A/m 6(3)(xiv) 10 I, I 1 ± 2.5 ± 1.3 ± 0.5 ± 0.25 tr max power frequency) of external origin.
Radiated, RF, f = 80 to 6000 MHz, 6(3)(xv)(a) 10 I 1 ± 3 ± 2 ± 1 ± 1 tr electromagnetic Fields Field strength ≤10 V/m Conducted disturbances, f = 0.15 to 80 MHz, 6(3)(xv)(b) 10 I 1 ± 3 ± 2 ± 1 ± 1 tr induced by radio Amplitude ≤10 V frequency fields (7) DC in the AC current Sinusoidal current, 6(3)(xvi) I /√2 1 ± 6 ± 3 ± 1.5 ± 1 max circuit (8) twice amplitude, half- wave rectified; I ≤I /√2 max High-order harmonics Superimposed: 0.02 6(3)(xvii) Itr 1 ± 1 ± 1 ± 0.5 ± 0.5 U ; 0.1 I ; 15 f to nom tr nom 40 f nom
(1) Only for poly-phase and single phase 3-wire meters.
(2) The error shift may exceed the value specified in the table provided the error is within ±2.5 %.
(3) For poly-phase meters the requirement is for symmetrical voltage variations.
(4) As long as the r.m.s. current is not higher than I and the peak value of the current is not higher than 1.41·I . max max Furthermore, the amplitude of individual harmonic components shall not exceed (I / h) for current and (0.12 · U / h) for 1 1 voltage, where h is the harmonic order.
(5) In the case of electromechanical meters, the error shift may exceed the value specified in the table provided the error is within ± 3.0 %.
(6) Only for poly-phase meters. Two phases interrupted is only for those connection modes where a missing phase means that energy can be delivered. This requirement applies only to fault conditions of the network, not for an alternative connection mode. A poly-phase meter which is powered from only one of its phases shall not have the voltage of that phase interrupted for the purposes of this test.
(7) Direct or indirect, conducted disturbances induced by radio-frequency fields.
(8) Only for direct connected meters.
(9) For class A, electromechanical meters, the requirement is not applicable below 10 I . tr
(10) Manufacturers may additionally include an alarm upon detection of a continuous (DC) magnetic induction of greater than 200 mT.
(11) For electromechanical meters, this value is doubled.
(vi) Allowed effects of disturbances,–
(a) General.– The meter shall withstand disturbances which may be encountered under conditions of normal use; as stated in 3.3.1, no significant fault shall occur for any of the disturbances listed in Table 5.
(b) Disturbances.– An error shift larger than that prescribed in Table 5 constitutes a significant fault. If a meter is operated under the conditions outlined in Table 5 and no current is applied, a change in the registers or pulses of the test output shall not be considered as a significant fault if the change in the registers or equivalent energy of the test output, expressed in kWh, is less than m ⋅U ⋅I ⋅10 −6 (critical change value), where m is the number of measuring nom max elements, U is expressed in volts and I is expressed in amperes.
nom max98 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] Table 5 Disturbances Disturbance Test Clause Level of Allowed Limit of error shift (%) for quantity disturbance effects meters of class A B C D Magnetic field 6(4)(ii) 1000 A/m, 3 s No - - - - (AC, power significant frequency) of fault external origin.
Electrostatic 6(4)(iii) 8 kV contact No - - - - Discharges discharge; 15 significant kV air fault discharge.
Fast transients 6(4)(iv) Voltage and 6.0 4.0 2.0 1.0 current
circuits: 4 kV;
Auxiliary
circuits: 2 kV.
Voltage dips 6(4)(v) Test a: 30 %, No - - - -
0.5 cycles significant
Test b: 60 %, fault 1 cycle Test c:
60 %, 25/30 cycles (3) Voltage 6(4)(v) 0 %, 250/300 - - - - interruptions cycles (3) Radiated, RF, 6(4)(vi) f = 80 to No - - - - electromagnetic 6000 MHz, 30 significant fields V/m, fault amplitude modulated, without current.
Surges on AC 6(4)(vii) Voltage No - - - -
mains power lines circuits: 2 kV significant line to line, 4 fault. kV line to earth;
Auxiliary
circuits: 1 kV line to line, 2 kV line to earth.
Damped 6(4)(viii) Voltage No 3.0 2.0 2.0 1.0
oscillatory waves circuits: significant immunity test(1) Common fault. The mode 2.5 kV, function of differential the meter mode 1.0 kV. shall not be perturbed.[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 99 Short-time over 6(4)(ix) Direct No Transformation operated current connected significant 1.0 0.5 0.05 0.05
meters: fault. Direct connected 30·I max; No damage 1.5 1.5 0.05 0.05 Transformer- shall occur. operated
meters:
20·I . max Impulse voltage 6(4)(x) 3 kV (≤100 No - - - - V); significant 6 kV (≤150 V) fault. ; No damage 10 kV (≤300 shall meter V) ;
12 kV (≤600 V).
Earth fault(2) 6(4)(xi) Earth fault in No 1.0 0.7 0.3 0.1 one phase significant fault.
No damage shall and operate correctly.
Operation of 6(4)(xii) Ancillary No 1/3 base mpe ½ ancillary devices devices significant base operated with fault. mpe I = I and min I max Vibration 6(4)(xiii)(a) Vibration in No 1/3 base mpe ½ three mutually significant base perpendicular fault. mpe axes Function of the meter shall not be impaired.
Shock 6(4)(xiii)(b) Pulse shape: No 1/3 base mpe ½ Half-sine, significant base Peak fault. mpe
acceleration:
300 ms-2, Pulse
duration: 18 ms Protection against 6(4)(xiv) 0.76 No - - - - solar radiation W·m2·nm-1 at alteration in 340 nm, with appearance cycling rig for or 66 days impairment in functionality, metrological100 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] properties and sealing.
Protection against 6(4)(xv) IP 5x, No - - - - ingress of dust category 2 interference enclosure with correct operation or impairment of safety, including tracking along creepage distances.
Dry heat 6(4)(xvi)(a) One standard No 1/3 base mpe ½ temperature significant base higher than fault. mpe upper specified temperature limit, 2 h Cold 6(4)(xvi)(b) One standard No 1/3 base mpe ½ temperature significant base lower than fault mpe lower specified temperature limit, 2 h Damp Heat 6(4)(xvi)(c), H1: 30 °C, 85 No ±0.2 ±0.1 ±0.05 ±0.05 6(4)(xvi)(d) %; H2: Cyclic significant 25 °C, 95 % fault.
to 40 °C, 93 No evidence %; H3: Cyclic of any 25 °C, 95 % mechanical to 55 °C, 93 damage or %. corrosion.
Water 6(4)(xvi)(e) H3 only, 0.07 No - - - - L/min (per significant nozzle), 0 ° fault. and 180 °, 10 No evidence min of any mechanical damage or corrosion.
Durability 6(4)(xvii) High current No 1/3 base mpe ½ and/or significant base temperature fault. mpe for a Sustained period of time[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 101
(1) Only for transformer operated meters.
(2) Only for three-phase four-wire transformer-operated meters intended for use in networks equipped with earth fault neutralizers
(3) These values are for 50 Hz / 60 Hz respectively If no significant fault occurs during the appropriate tests described in Part 2 of this Notification, the meter is presumed to comply with the requirements of this sub-clause.
(4) Requirements for interval and multi-tariff meters.– Interval meters shall be able to measure and store data relevant for billing. The minimum storage period for this data shall be determined by Central Electricity Authority or any other organisation authorised by the Government. For interval meters, the summation of interval data shall equate to the cumulative register value over the same period.
For multi-tariff meters, only a single register (in addition to the cumulative register) shall be active at any time. The summation of values recorded in each multi-tariff register shall equate to the value recorded in the cumulative register.
(5) Meter markings.– The following information must be marked on every meter: • Manufacturer • U nom • I max • I tr I • min • Approval mark(s) • Serial number • Number of phases • Number of wires • Register multiplier (if other than unity) • Meter constant(s) • Year of manufacture • Accuracy class • Directionality of energy flow if the meter is bidirectional or unidirectional. No marking is required if the meter is capable only of positive direction energy flow.
• Meter type • Temperature range • Humidity and water protection information • Impulse voltage protection information • fnom • The connection mode(s) for which the meter is specified • Connection terminals uniquely identified to distinguish between terminals.
The markings shall be indelible, distinct and legible from outside the meter. The markings of meters intended for outdoor locations shall withstand solar radiation. Multiple values of U and nom f may be marked if so specified by the manufacturer.
nom If the serial number is affixed to dismountable parts, the serial number shall also be provided in a position where it is not readily disassociated from parts determining the metrological characteristics.102 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] Symbols or their equivalent may be used where appropriate.
(6) Protection of metrological properties.–
(i) General
(a) Electricity meters shall be provided with the means to protect their metrological properties.
Only the authorized persons shall be allowed to access for software protection (iii), parameter protection (iv) and checking facility event record (ix).
(b) All means to protect the metrological properties of an electricity meter intended for outdoor locations shall withstand solar radiation.
(ii) Software identification.– Legally relevant software of an electricity meter shall be clearly identified with the software version or another token. The identification may consist of more than one part but at least one part shall be dedicated to the legal purpose.
The identification shall be inextricably linked to the software itself and shall be presented on command or displayed during operation.
As an exception, an imprint of the software identification on the electricity meter shall be an
acceptable solution if it satisfies the three following conditions:
(a) The user interface does not have any control capability to activate the indication of the software identification on the display, or the display does not technically allow the identification of the software to be shown (analog indicating device or electromechanical counter).
(b) The electricity meter does not have an interface to communicate the software identification.
(c) After production of the electricity meter a change of the software is not possible, or only possible if the hardware or a hardware component is also changed.
The manufacturer of the hardware or the concerned hardware component is responsible for ensuring that the software identification is correctly marked on the concerned meter.
The software identification and the means of identification shall be stated in the type approval certificate.
(iii) Software protection,–
(a) Prevention of misuse.– An electricity meter shall be constructed in such a way that possibilities for unintentional, accidental, or intentional misuse are minimal.
(b) Fraud protection
(ba) The legally relevant software shall be secured against unauthorized modification, loading, or changes by swapping the memory device. A secure means, such as mechanical or electronic sealing, is required to secure electricity meters having an option to load software/parameters.
(bb) Only clearly documented functions (see 4.1) are allowed to be activated by the user interface, which shall be realized in such a way that it does not facilitate fraudulent use.[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 103
(bc) Software protection comprises appropriate sealing by mechanical, electronic and/or cryptographic means, making an unauthorized intervention impossible or evident.
Examples:
1) The software of a measuring instrument is constructed such that there is no way to modify the parameters and legally relevant configuration but via a switch protected menu. This switch is mechanically sealed in the inactive position, making modification of the parameters and of the legally relevant configuration impossible. To modify the parameters and configuration, the switch has to be switched, inevitably breaking the seal by doing so.
2) The software of a measuring instrument is constructed such that there is no way to access the parameters and legally relevant configuration but by authorized persons. If a person wants to enter the parameter menu item he has to insert his smart card containing a PIN as part of a cryptographic certificate. The software of the instrument is able to verify the authenticity of the PIN by the certificate and allows the parameter menu item to be entered. The access is recorded in an audit trail including the identity of the person (or at least of the smart card used).
(iv) Parameter protection,–
(a) Parameters that fix the legally relevant characteristics of the electricity meter shall be secured against unauthorized modification. If necessary for the purpose of verification, the current parameter settings shall be able to be displayed.
Device-specific parameters may be adjustable or selectable only in a special operational mode of the electricity meter. They may be classified as those that should be secured (unalterable) and those that may be accessed (settable parameters) by an authorized person, e.g. the instrument owner, repairer.
Type-specific parameters have identical values for all specimens of a type. They are fixed at type approval of the instrument.
Note 1: A simple password is not a technically acceptable solution for protecting parameters.
Note 2: Authorized persons may be allowed to access a limited set of device-specific parameters.
Such a set of device specific parameters and its access limitations/rules should be clearly documented.
(b) Zeroing the register that stores the total energy metered shall be considered as a modification of a device specific parameter. Therefore all relevant requirements applicable to device specific parameters are applicable to the zeroing operation.
(c) When modifying a device-specific parameter, the meter shall stop registering energy.
(d) Certain device-specific parameters shall be available to the user. However, the measuring instrument shall be fitted with a facility to automatically and non-erasably record any adjustment of the device-specific parameter, e.g. an audit trail. The instrument shall be capable of presenting the recorded data.
The traceability means and records are part of the legally relevant software and should be protected as such. The software employed for displaying the audit trail belongs to the fixed104 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] legally relevant software.
Note: An event counter is not a technically acceptable solution.
(v) Separation of electronic devices and sub-assemblies.– Metrologically critical parts of an electricity meter – whether software or hardware parts – shall not be inadmissibly influenced by other parts of the meter.
(a) Sub-assemblies or electronic devices of an electricity meter that perform legally relevant functions shall be identified, clearly defined, and documented. They form the legally relevant part of the measuring system. If the sub-assemblies that perform legally relevant functions are not identified, all sub-assemblies shall be considered to perform legally relevant functions.
Example:
1) An electricity meter is equipped with an optical interface for connecting an electronic device to read out measurement values. The meter stores all the relevant quantities and keeps the values available for being read out for a sufficient time span. In this system only the electricity meter is the legally relevant device. Other legally non-relevant devices may exist and may be connected to the interface of the instrument provided requirement 3(6)(v)(b) is fulfilled.
Securing of the data transmission itself [see 3(6)(vii)] is not required.
(b) During type testing, it shall be demonstrated that the relevant functions and data of sub- assemblies and electronic devices cannot be inadmissibly influenced by commands received via the interface.
This implies that there is an unambiguous assignment of each command to all initiated functions or data changes in the sub-assembly or electronic device.
Note: If “legally relevant” sub-assemblies or electronic devices interact with other “legally relevant” sub-assemblies or electronic devices, refer to 3(6)(vii).
Examples:
1) The software of the electricity meter [see example of 3(6)(v)(a) above] is able to receive commands for selecting the quantities required. It combines the measurement value with additional information – e.g. time stamp, unit – and sends this data set back to the requesting device. The software only accepts commands for the selection of valid allowed quantities and discards any other command, sending back only an error message. There may be securing means for the contents of the data set but they are not required, as the transmitted data set is not subject to legal control.
2) Inside the housing that can be sealed there is a switch that defines the operating mode of
the electricity meter: one switch setting indicates the verified mode and the other the non- verified mode (securing means other than a mechanical seal are possible; see examples in 3(6)(iii)(b)(bc). When interpreting received commands the software checks the position of the
switch: in the non-verified mode the command set that the software accepts is extended compared to the mode described above; e.g. it may be possible to adjust the calibration factor by a command that is discarded in the verified mode.
(vi) Separation of software parts,–
(a) All software modules (programs, subroutines, objects, etc.) that perform legally relevant[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 105 functions or that contain legally relevant data domains form the legally relevant software part of an electricity meter, which shall be made identifiable as described in 3(6)(ii). If the software modules that perform legally relevant functions are not identified, the whole software shall be considered as legally relevant.
(b) If the legally relevant software part communicates with other software parts, a software interface shall be defined. All communication shall be performed exclusively via this interface.
The legally relevant software part and the interface shall be clearly documented. All legally relevant functions and data domains of the software shall be described to enable a type approval authority to decide on correct software separation.
(c) The data domain forming the software interface including the code that exports from the legally relevant part to the interface data domain and the code that imports from the interface to the legally relevant part shall be clearly defined and documented. The declared software interface shall not be circumvented.
(d) There shall be an unambiguous assignment of each command to all initiated functions or data changes in the legally relevant part of the software. Commands that communicate through the software interface shall be declared and documented. Only documented commands are allowed to be activated through the software interface. The manufacturer shall state the completeness of the documentation of commands.
(vii) Storage of data, transmission via communication systems,–
(a) General.– If measurement values are used at another place than the place of measurement or at a later time than the time of measurement they possibly have to leave the meter (electronic device, sub-assembly) and be stored or transmitted in an insecure environment before they are used for legal purposes. In this case the following requirements apply:
(aa) The measurement value stored or transmitted shall be accompanied by all relevant information necessary for future legally relevant use.
(ab) The data shall be protected by software means to guarantee the authenticity, integrity and, if necessary correctness of the information concerning the time of measurement. The software that displays or further processes the measurement values and accompanying data shall check the time of measurement, authenticity, and integrity of the data after having read them from the insecure storage or after having received them from an insecure transmission channel. If an irregularity is detected, the data shall be discarded or marked unusable.
Confidential keys employed for protecting data shall be kept secret and secured in the electricity meter. Means shall be provided whereby these keys can only be input or read if a seal is broken.
(ac) Software modules that prepare data for storing or sending, or that check data after reading or receiving belong to the legally relevant software part.
(b) Automatic storing
(ba) When data storage is required, measurement data must be stored automatically when the measurement is concluded, i.e. when the final value has been generated. When the final value106 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] is from a calculation, all data that are necessary for the calculation must be automatically stored with the final value.
(bb) The storage device must have sufficient permanency to ensure that the data are not corrupted under normal storage conditions. There shall be sufficient memory storage for any particular application.
(bc) Stored data may be deleted if either • the transaction is settled, or • these data are printed by a printing device subject to legal control.
Note: This shall not apply to the cumulative register and audit trail.
(bd) After the requirements in 3(6)(vii)(b)(bc) are fulfilled and when the storage is full, it is
permitted to delete memorized data when both of the following conditions are met: • data are deleted in the same order as the recording order and the rules established for the particular application are respected;
• deletion is carried out either automatically or after a special manual operation that may require specific access rights.
(c) Data transmission,–
(ca) The measurement shall not be inadmissibly influenced by a transmission delay.
(cb) If network services become unavailable, no legally relevant measurement data shall be lost.
(d) Time stamp.– The time stamp shall be read from the clock of the device. Setting the clock is considered as being legally relevant. Appropriate protection means shall be taken according to 3(6)(iv).
Internal clocks may be enhanced by specific means (e.g. software means) to reduce their uncertainty when the time of measurement is necessary for a specific field (e.g. multi-tariff meter, interval meter).
(viii) Maintenance and re-configuration.– Updating the legally relevant software of an electricity meter in the field should be considered as • a modification of the electricity meter, when exchanging the software with another approved version, or • a repair of the electricity meter, when re-installing the same version.
An electricity meter which has been modified or repaired while in service shall require re- verification.
The software update mechanism shall be disabled by means of a sealable setting (physical switch, secured parameter) so that it must not be possible to update legally relevant software without breaking the seal.[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 107 Software which is not necessary for the correct functioning of the electricity meter does not require verification after being updated.
(a) Only versions of legally relevant software that conform to the approved type are allowed for use. This issue concerns verification in the field.
(b) Verified update.– The software to be updated can be loaded locally, i.e. directly on the measuring device or remotely via a network. Loading and installation may be two different steps or combined into one, depending on the needs of the technical solution. A person should be on the installation site of the electricity meter to check the effectiveness of the update. After the update of the legally relevant software of an electricity meter (exchange with another approved version or re-installation) the electricity meter is not allowed to be employed for legal purposes before a verification of the instrument has been performed and the securing means have been renewed.
(c)Traced update.– The software is implemented in the instrument according to the requirements for traced update (ca to cg). Traced update is the procedure of changing software in a verified instrument or device after which the subsequent verification by a responsible person on site is not necessary. The software to be updated can be loaded locally, i.e. directly on the measuring device or remotely via a network. The software update is recorded in an audit trail.
The procedure of a traced update comprises several steps: loading, integrity checking, checking of the origin (authentication), installation, logging and activation.
(ca) Traced update of software shall be automatic. On completion of the update procedure the software protection environment shall be at the same level as required by the type approval.
(cb) The target electricity meter (electronic device, sub-assembly) shall have fixed legally relevant software that cannot be updated and that contains all of the checking functions necessary for fulfilling traced update requirements.
(cc) Technical means shall be employed to guarantee the authenticity of the loaded software, i.e. that it originates from the owner of the type approval certificate. If the loaded software fails the authenticity check, the instrument shall discard it and use the previous version of the software or switch to an inoperable mode.
(cd) Technical means shall be employed to ensure the integrity of the loaded software, i.e. that it has not been inadmissibly changed before loading. This can be accomplished by adding a checksum or hash code of the loaded software and verifying it during the loading procedure. If the loaded software fails this test, the instrument shall discard it and use the previous version of the software or switch to an inoperable mode. In this mode, the measuring functions shall be inhibited. It shall only be possible to resume the download procedure, without omitting any steps in the process for traced update.
(ce) Appropriate technical means, e.g. an audit trail, shall be employed to ensure that traced updates of legally relevant software are adequately traceable within the instrument for subsequent verification and surveillance or inspection.
The audit trail shall contain at minimum the following information: success / failure of the update procedure, software identification of the installed version, software identification of the previous108 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] installed version, time stamp of the event, identification of the downloading party. An entry shall be generated for each update attempt regardless of the success.
The storage device that supports the traced update shall have sufficient capacity to ensure the traceability of traced updates of legally relevant software between at least two successive verifications in the field/inspection. After having reached the limit of the storage for the audit trail, it shall be ensured by technical means that further downloads are impossible without breaking a seal.
Note: This requirement enables inspection authorities, which are responsible for the metrological surveillance of legally controlled instruments, to back-trace traced updates of legally relevant software over an adequate period of time .
(cf) It is assumed that the manufacturer of the electricity meter keeps his customer well informed about updates of the software, especially the legally relevant part, and that the customer will not refuse updates. Furthermore it is assumed that manufacturer and customer, user, or owner of the instrument will agree on an appropriate procedure of performing a download depending on the use and location of the instrument.
(cg) If the requirements in 3(6)(viii)(c)(ca) through 3(6)(viii)(c)(cf) cannot be fulfilled, it is still possible to update the legally non-relevant software part. In this case the following requirements
shall be met: • there is a distinct separation between the legally relevant and non-relevant software; • the whole legally relevant software part cannot be updated without breaking a seal; • it is stated in the type approval certificate that updating the legally non-relevant part is acceptable.
(ix) Checking facility event record.– If the meter is equipped with a checking facility, the event record of the facility shall have room for at least 100 events and shall be of a first-in-first-out type. The event record may not be changed or zeroed without breaking a seal and/or without authorized access, for example by means of a code (password) or of a special device (hard key, etc.).
(7) Suitability for use,-
(i) Readability of result.– The meter shall have one (or more) indicating device(s) which is (are) capable of presenting or displaying the numerical value of each legal unit of measure for which the meter is approved. The indicating device shall be easy to read and the characters of measurement results shall as minimum be 4 mm high. Any decimal fractions shall be clearly indicated; for mechanical registers, any decimal fraction drum shall be marked differently.
The indicating device shall not be significantly affected by exposure to normal operating conditions over the maximum duration of the meter lifetime.
The indicating device shall be able to display all data relevant for billing purposes. In the case of multiple values presented by a single indicating device it shall be possible to display the[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 109 content of all relevant memories. For automatic sequencing displays, each display of register for billing purposes shall be retained for a minimum of 5 s.
For multi -tariff meters, the register which reflects the active tariff shall be indicated. It shall be possible to read each tariff register locally and each register shall be clearly identified.
Electronic registers shall be non-volatile so that they retain stored values upon loss of power.
Stored values shall not be overwritten and shall be capable of being retrieved upon restoration of power. The register shall be capable of storing and displaying an amount of energy that corresponds to the meter running at P = U ·I ·n for at least 4000 h, where n is the number nom max of phases. This capability for storage and display applies to all registers relevant for billing including positive and negative flow registers for bi-directional meters and tariff registers for multi-tariff meters.
In the case of electronic registers, the minimum retention time for results is one year for a disconnected meter. Electronic indicating devices shall be provided with a display test that switches all the display segments on then off for the purpose of determining whether all display segments are working.
(ii) Testability.– The meter shall be equipped with a test output for efficient testing, such as a rotor with a mark or a test pulse output. If the design of the test output is such that the pulse rate does not correspond to the measured power in every given relevant time interval, the manufacturer shall declare the necessary number of pulses to ensure a standard deviation of measurement less than 0.1 base mpe, at I , I and I .
max tr min The relation between the measured energy given by the test output and the measured energy given by the indicating device shall comply with the marking on the name-plate.
The wavelength of the radiated signals for emitting systems shall be between 550 nm and 1 000 nm. The output device in the meter shall generate a signal with a radiation strength E over a T defined reference surface (optically active area) at a distance of 10 mm ±1 mm from the surface of the meter, with the following limiting values:
ON-condition: 50μW/cm2 ≤E ≤ 7500μW/cm2 T OFF-condition: E ≤ 2μW/cm2 T
(8) Durability.– The meter shall be designed to maintain an adequate stability of its metrological characteristics over a period of time specified by the manufacturer, provided that it is properly installed, maintained and used according to the manufacturer’s instructions when in the environmental conditions for which it is intended. The manufacturer shall provide evidence to support the durability claim.
The meter shall be designed to reduce as far as possible the effect of a defect that would lead to an inaccurate measurement result.
The meter shall be designed and manufactured such that either a) significant durability errors do not occur, or b) significant durability errors are detected and acted upon by means of a durability protection.110 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)]
(9) Presumption of compliance.– The type of a meter is presumed to comply with the provisions in clause 3 if it passes the examination and tests specified in Part 2 of this Notification.
Part 2 Metrological controls and performance tests
4. Type approval,–
(1) Documentation.– The documentation submitted with the application for type approval shall
include: • identification of the type, including ▪ name or trademark and type designation, ▪ version(s) of hardware and software, ▪ drawing of name plate; • metrological characteristics of the meter, including ▪ a description of the principle(s) of measurement, ▪ metrological specifications such as accuracy class and rated operating conditions (clause 3(1)), ▪ any steps which should be performed prior to testing the meter;
• the technical specification for the meter, including ▪ a block diagram with a functional description of the components and devices, ▪ drawings, diagrams and general software information, explaining the construction and operation, including interlocks, ▪ description and position of seals or other means of protection, ▪ documentation related to durability characteristics, ▪ any document or other evidence that the design and construction of the meter complies with the requirements of this Notification, ▪ specified clock frequencies, ▪ energy consumption of the meter;
• user manual; • installation manual; • a description of the checking facility for significant faults, if applicable;
In addition, software documentation shall include • a description of the legally relevant software and how the requirements are met: ▪ list of software modules that belong to the legally relevant part including a declaration that all legally relevant functions are included in the description;
▪ description of the software interfaces of the legally relevant software part and of the commands and data flows via this interface including a statement of completeness; ▪ description of the generation of the software identification;
▪ list of parameters to be protected and description of protection means;[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 111 • a description of security means of the operating system (password, etc. if applicable); a description of the (software) sealing method(s);
• an overview of the system hardware, e.g. topology block diagram, type of computer(s), type of network, etc. • where a hardware component is deemed legally relevant or where it performs legally relevant functions, this should also be identified;
• a description of the accuracy of the algorithms (e.g. filtering of A/D conversion results, price calculation, rounding algorithms, etc.); • a description of the user interface, menus and dialogues; • the software identification and instructions for obtaining it from an instrument in use;
• list of commands of each hardware interface of the measuring instrument / electronic • device / sub-assembly including a statement of completeness; • list of durability errors that are detected by the software and if necessary for understanding, a description of the detecting algorithms;
▪ a description of data sets stored or transmitted; ▪ if fault detection is realized in the software, a list of faults that are detected and a description of the detecting algorithm; ▪ the operating manual.
Furthermore, if the type approval is to be based on existing type test documentation, the application for type approval shall be accompanied by type test documents or other evidence that supports the assertion that the design and characteristics of the measuring instrument comply with the requirements of this Notification.
(2) Type definition.– Meters produced by the same manufacturer may form a type, provided they have similar metrological properties resulting from the use of the same uniform construction of parts/modules that determine the metrological properties.
A type may have several current ranges and several values of the nominal voltage and frequency, and include several connection modes and several ancillary devices.
Note: The same uniform construction normally means the same construction of the measuring elements, the same construction of metering software, the same construction of the register and indicating device, the same temperature compensation mechanism, the same construction of case, terminal block, and mechanical interface.
(i) Type test sampling.– The manufacturer shall provide at least as many specimens of the meter as are required for testing. The type test shall be made on one or more specimens of the meter, selected by the type test body, to establish its specific characteristics and to prove its conformity with the requirements of this Notification. In the case of modifications to the meter made after or during the type test and affecting only part of the meter, the issuing body may deem it sufficient to perform limited tests on the characteristics that may be affected by the modifications.
(3) Validation procedure.– The validation procedure consists of a combination of analysis methods and tests as shown in Table 6. The abbreviations used are described in Table 7.112 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] Table 6 Validation procedures for specified requirements Requirement Validation procedure 3(6)(ii) Software identification AD + VFTSw 3(6)(iii)(a) Prevention misuse AD + VFTSw 3(6)(iii)(b) Fraud protection AD + VFTSw 3(6)(iv) Parameter protection AD + VFTSw Separation of electronic devices and sub- 3(6)(v) assemblies AD 3(6)(vi) Separation of software parts AD Storage of data, transmission via 3(6)(vii) communication systems AD + VFTSw Data protection with respect to time of 3(6)(vii)(a)(ab) measurement AD + VFTSw 3(6)(vii)(b) Automatic storing AD + VFTSw 3(6)(vii)(c)(ca) Transmission delay AD + VFTSw 3(6)(vii)(c)(ca) Transmission interruption AD + VFTSw 3(6)(vii)(d) Time stamp AD + VFTSw 3(6)(viii) Maintenance and re-configuration AD Table 7 Validation procedure abbreviations used in Table 6 Abbreviation Description Related Annex C AD Analysis of the documentation and Para 1 validation of the design VFTSw Validation by functional testing of Para 2 software functions
5. Test program.– The initial intrinsic error shall be determined as the first test on the meter, as described in 6(2)(i).
At the beginning of any series of tests, the meter shall be allowed to stabilize with voltage circuits[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 113 energized for a period of time specified by the manufacturer.
The order of the test points for initial intrinsic error shall be from lowest current to highest current and then from highest current to lowest current. For each test point, the resulting error shall be the mean of these measurements. For I , the maximum measurement time shall be max 10 min including stabilizing time.
The determination of the intrinsic error (at reference conditions) shall always be carried out before tests of influence quantities and before disturbance tests that relate to a limit of error shift requirement or to a significant fault condition for error.
Otherwise the order of tests is not prescribed.
Test (pulse) outputs may be used for tests of accuracy requirements. A test must then be made to ensure that the relation between the basic energy register and the used test output complies with the manufacturer’s specification.
If a meter is specified with alternate connection modes, such as one-phase connections for poly- phase meters, the tests for base maximum permissible error in accordance with 3(3)(iii) shall be made for all specified connection modes.
More stringent test regimes may be prescribed by Director (Legal Metrology) than those described in this clause, if required.
6. Test procedures for type approval,–
(1) Test conditions.– Unless otherwise stated in the individual test instructions, all influence quantities except for the influence quantity being tested shall be held at reference conditions as given by Table 8 during type approval tests.
Table 8 Reference conditions and their tolerances Quantity Reference conditions Tolerance Voltage(s) (2) Unom ± 1 % Ambient temperature 23 ºC(1) ± 2 ºC Frequency fnom ± 0.3 % Wave-form Sinusoidal d ≤ 2 % Magnetic induction of 0 T B ≤ 0.05 mT external origin at reference frequency Electromagnetic RF fields 30 0 V/m ≤ 1 V/m kHz – 6 GHz Operating position for Mounting as stated by ± 0.5º instruments sensitive to manufacturer position Phase sequence for poly- L1, L2, L3 - phase meters Load balance Equal current in all current ± 2 % (current) and ± 2º circuits (phase angle)
(1) Tests may be performed at other temperatures if the results are corrected to the reference temperature by applying the temperature coefficient established in the type tests, and provided an appropriate uncertainty analysis is carried out.114 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)]
(2) The requirement applies to both phase-to-phase and phase-neutral for poly-phase meters
Note: The reference conditions and their tolerance are given to ensure reproducibility between testing laboratories, not to determine the accuracy of the tests. The demands on short time stability during test for influence factors may be much higher than shown in this table.
Table 9 Load conditions and their tolerances in tests Quantity Conditions Tolerance Current range of device under Current(s) test Class A, B: ± 2 % Class C, D: ± 1 % Power factor range of device current to voltage phase difference ± Power factor under test 2º
Note: The load conditions and their tolerance are given to ensure reproducibility between testing laboratories, not to determine the accuracy of the tests. The demands on short time stability during test for influence factors may be much higher than shown in Table 9.
For most tests, the measured power will be constant if the other influence quantities are kept constant at reference conditions. However, this is not possible for some tests such as influence of voltage variation and load unbalance. Therefore, the error shift shall always be measured as the shift of the relative error and not of the absolute power.
(2) Tests for compliance with maximum permissible errors
(i) Determination of initial intrinsic error,-
Object of the table Test: To verify that the error of the meter at reference conditions is less than the relevant base mpe given in Table 2.
Test procedure: Meters that are specified as being capable of bidirectional or unidirectional energy measurement as described in 3(3)(ii) shall meet the relevant base mpe requirements of Table 2 for energy flow in both positive and negative directions.
Meters that are specified as capable of measuring only positive energy flow as described in 3(3)(ii) shall meet the relevant base mpe requirements of Table 2 for positive energy flow.
These meters shall also be subjected to reversed energy flow, in response to which the meter shall not register energy in the primary register or emit more than one pulse from the test output. The test time shall be at least 1 min, or the time that the test output would register 10 pulses in the positive energy flow direction, or the time that the primary register would register 2 units of the least significant digit in the positive energy flow direction, whichever is longest.
For reverse running detent designs that are prone to be affected by heating, the test time shall be extended to 10 min at I . max[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 115
Mandatory test Points: Mandatory test points are specified in Table 10 for positive, negative and reverse flow tests. Two mandatory test points shall be selected as specified in Table 10.
Note: For the calculation of the combined maximum error as defined in Annex A (A((2)(i) or A(2)(ii)) it may be required by to implement some additional test points to cover the power factor range of at least of 0.5 inductive to 0.8 capacitive over the current range of at least I min to I .
max Table 10 Mandatory test points for the determination of initial intrinsic error test
Current Power factor Test point mandatory for:
Positive flow Negative flow Reverse flow I Unity Yes No Yes min I Unity Yes Yes No tr Most inductive (1) Yes Yes No Most capacitive (1) Yes Yes No A test point Unity Yes No No within range I Most inductive (1) Yes No No tr to I may be Most capacitive (1) Yes No No max selected I Unity Yes Yes Yes max Most inductive (1) Yes Yes No Most capacitive (1) Yes Yes No
(1) Most inductive or capacitive according to Table 1.
(ii) Self-heating,–
Object of the test: To verify that the meter is able to carry I continuously as max specified in Table 4.
Test procedure: The test shall be carried out as follows: the voltage circuits shall first be energized at reference voltage for at least 1 h for class A meters and at least 2 h for meters of all other classes. Then, with the meter otherwise at reference conditions, the maximum current shall be applied to the current circuits. The cable to be used for energizing the meter shall be made of copper, have a length of 1 m and a cross-
section which ensures that the current density is between 3.2 A/mm2 and 4 A/mm2.
The error of the meter shall be monitored at unity power factor and at intervals short enough to record the curve of error variation as a function of time. The test shall be carried out for at least 1 h, and in any event until the variation of error over any 20-minute period does not exceed 10 % of the base maximum permissible error. The error shift compared to the intrinsic error shall comply with the requirements given in Table 4 at all times.
If the error shift has not leveled out (so that the variation of error over any 20-minute period does not exceed 10 % of the base maximum permissible error) by the end of the test, the meter shall either be allowed to return to its initial temperature and the entire test repeated116 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] at power factor = 0.5 inductive or, if the load can be changed in less than 30 seconds, the error of the meter shall be measured at I and power factor = 0.5 inductive and it shall be checked max that the error shift compared to the intrinsic error complies with the requirements given in Table 4.
(iii) Starting current,-
Object of the test: To verify that the meter starts and continues to operate at I as given st by Table 1.
Test procedure: The meter shall be subjected to a current equal to the starting current I . If the meter is designed for the measurement of energy st in both directions, then this test shall be applied with energy flowing in each direction. The effect of an intentional delay in measurement after reversal of the energy direction should be taken into account when performing the test.
The meter shall be considered to have started if the output produces pulses (or revolutions) at a rate consistent with the base maximum permissible error requirements given by Table
2.
The expected time, τ, between two pulses (period) is given by:
3.6X106 seconds, m.k.U .I nom st
where: k is the number of pulses emitted by the output device of the meter per kilowatt-hour (imp/kWh) or the number of revolutions per kilowatt-hour (rev/kWh); m is the number of elements; the nominal voltage U is expressed in volts; and the starting nom current I is expressed in amperes.
st
Steps for the test procedure:
1. Start the meter.
2. Allow 1.5·τ seconds for the first pulse to occur.
3. Allow another 1.5·τ seconds for the second pulse to occur.
4. Determine the effective time between the two pulses.
5. Allow the effective time (after the second pulse) for the third pulse to occur.
Mandatory test points: I at unity power factor. st
(iv) Test of no-load condition,-[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 117 Object of the To verify the no-load performance of the meter given in 3(3)(iv). For
test:
Test procedure: For this test, there shall be no current in the current circuit. The test shall be performed at U . nom For meters with a test output, the output of the meter shall not produce more than one pulse. For an electromechanical meter, the rotor of the meter shall not make a complete revolution.
The minimum t shall test be period ∆ ∆t≥ 100X103 h, b.k.m.U .I nom min
where: b is the base maximum permissible error at I expressed as a percentage min (%) and is taken as a positive value; k is the number of pulses emitted by the output device of the meter per kilowatt-hour (imp/kWh) or the number of revolutions per kilowatt-hour (rev/kWh);
m is the number of elements; the nominal voltage U is expressed in volts; and nom the minimum current I is expressed in amperes. min For transformer-operated meters with primary rated registers where the value of k (and possibly U ) are given as primary side values, the constant nom k (and U ) shall be recalculated to correspond to secondary side values nom (of voltage and current).
Note: As an example, the minimum test period would be 0.46 h (27.8 min) for a class B meter (b = 1.5 %) with the following specifications: k = 1000 imp/kWh, m = 1, U = 240 V and nom I = 0.6 A. min
(v) Meter constants,– Object of the To verify that the relationship between the basic energy register and
test: the used test output(s) complies with the manufacturer’s specification as required in 3(7)(ii). The relative difference must not be greater than one tenth of the base maximum permissible error. This test is only applicable if test (pulse) outputs are used to test accuracy requirements.
Test procedure: All registers and pulse outputs that are under legal control must be tested unless a system is in place that guarantees the identical behavior of all meter constants.118 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] The test shall be performed by passing a quantity of energy E through the meter, where E is at
least:
E = 1000.R Wh, min b
where:
R is the apparent resolution of the basic energy register (1) expressed in Wh; and b is the base maximum permissible error (2) expressed as a percentage (%).
The relative difference between the registered energy and the energy passed through the meter as given by the number of pulses from the test output shall be computed.
Allowed effect: The relative difference shall not be greater than one tenth of the base maximum permissible error.
Mandatory test The test shall be performed at a single arbitrary current I ≥I. tr
points:
Note (1): Any means may be used to enhance the apparent resolution R of the basic register, as long as care is taken to ensure that the results reflect the true resolution of the basic register.
Note (2): The value of b shall be selected from Table 2 according to the chosen test point. The value of b may differ to that applicable for the no-load test.
(3) Tests for influence quantities
(i) General.– The purpose of these tests is to verify the requirements of 3(3)(iii) due to the variation of a single influence quantity. For influence quantities listed in Table 4, it shall be verified that the error shift due to the variation of any single influence quantity is within the corresponding limit of error shift stated in Table 4 (see also the definition of maximum permissible error shift in 2(2)(xx)).
(ii) Temperature dependence,– Object of the To verify that the temperature coefficient requirements of Table 3 are test: fulfilled.
Test procedure: For each test point, the error of the meter shall be determined at the reference temperature, at each of the upper and lower ambient temperature limits specified for the meter, and at a sufficient number of other temperatures forming temperature intervals of between 15 K and 23 K that span the specified temperature range.
Furthermore, for each test point and for each temperature interval given by adjacent upper or lower temperature limits including the reference temperature, the (mean) temperature coefficient, c, shall be determined as follows:
c = e-e u l t-t u l[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 119 where e and e are the errors at the uppermost and the lowest temperatures respectively in u l the temperature interval of interest; and t and t are the uppermost and the lowest temperatures respectively in the temperature interval u l of interest.
Each temperature coefficient shall be in accordance with the requirements of Table 3.
Mandatory test The test shall, at minimum, be performed at PF = 1 and PF = 0.5
points: inductive and for currents of I, 10 I and I . tr tr max
Note: For the calculation of the combined maximum error as defined in Annex A [A(2)(i) or A(2)(ii)] it may be required to implement some additional test points to cover the power factor range of at least 0.5 inductive to 0.8 capacitive over the current range of at least I to I .
min max
(iii) Load balance,– Object of the To verify that the error shift due to load balance complies with the
test: requirements of Table 4. This test is only for poly-phase meters and for single-phase three-wire meters.
Test procedure: The error of the meter with current in one current circuit only shall be measured and compared to the intrinsic error at balanced load. During the test, reference voltages shall be applied to all voltage circuits.
Mandatory test The test shall be performed for all current circuits at PF = 1and PF =
points: 0.5 inductive, and, at minimum, for currents of 10 I and I for direct tr max eters, and, at minimum, at I for transformer operated meters. max
Note: For the calculation of the combined maximum error as defined in Annex A [A(2)(ii)] it may be required to implement some additional test points to cover the power factor range of at least of 0.5 inductive to 0.8 capacitive over the current range of at least I to I .
min max
(iv) Voltage variation,– Object of the To verify that the error shift due to voltage variations complies with
test: the requirements of Table 4.
Test procedure: The error shift, compared to the intrinsic error at U , shall be measured nom when the voltage is varied within the corresponding rated operating range.
For poly-phase meters, the test voltage shall be balanced. If several U nom values are stated, the test shall be repeated for each U value. nom Mandatory test The test shall, at minimum, be performed at PF = 1 and PF = 0.5
points: inductive, for a current of 10 I, and at voltages 0.9 U and 1.1 U tr nom nom.
Note: For the calculation of the combined maximum error as defined in Annex A [A(2)(i) or A(2)(ii)] it may be required to implement some additional test points to cover the power factor range of at least of 0.5 inductive to 0.8 capacitive over the current range of at least I to I .
min max120 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)]
(v) Frequency variation,–
Object of the test: To verify that the error shift due to frequency variations complies with the requirements of Table 4.
Test procedure: The error shift, compared to the intrinsic error at f , shall be measured nom when the frequency is varied within the corresponding rated operating range. If several f values are stated, the test shall be repeated with each nom f value.
nom Mandatory test The test shall, at minimum, be performed at PF = 1 and PF = 0.5
points: inductive, for a current of 10 I, and at frequencies of 0.98 f and 1.02 tr nom f . nom
Note: For the calculation of the combined maximum error as defined in Annex [A(A(2)(i) or A(2)(ii)] it may be required to implement some additional test points to cover the power factor range of at least of 0.5 inductive to 0.8 capacitive over the current range of at least I to I .
min max
(vi) Harmonics in voltage and current,–
Object of the test: To verify that the error shift due to harmonics complies with the requirements.
Test procedure: The error shift, compared to the intrinsic error at sinusoidal conditions, shall be measured when harmonics are added in both the voltage and the current. The test shall be performed using the quadriform and peaked waveforms specified in Table11 and Table 12 respectively. The amplitude of a single harmonic shall not be more than 0.12 U/h for voltage and I/h 1 1 for the current, where h is the harmonic number and U and I are the 1 1 respective fundamentals. Plots of the current amplitude for the waveforms in Table 11 and Table 12 are shown in Figure 1 and Figure 2 respectively.
The r.m.s. current may not exceed I , i.e. for Table 11, the max fundamental current component I may not exceed 0.93 I . The peak 1 max value of the current may not exceed 1.4 I , i.e. for Table 12, the max fundamental current component I (r.m.s.) may not exceed 0.568 I 1 max.
Harmonic amplitudes are calculated relative to the amplitude of the fundamental frequency component of the voltage or current respectively.
Phase angle is calculated relative to the zero-crossing of the fundamental frequency voltage or current component respectively.
Mandatory test The test shall, at minimum, be performed at 10 I, PF = 1, where the tr
points: power factor is given for the fundamental component.
Note: For the calculation of the combined maximum error as defined in Annex A [A(2)(ii)] it may be required to implement some additional test points to cover the power factor range of at least of 0.5 inductive to 0.8 capacitive over the current range of at least I to I .
min max[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 121 Table 11 Quadriform waveform Harmonic Current Current Voltage Voltage phase number amplitude phase angle amplitude Angle 1 100 % 0° 100 % 0° 3 30 % 0° 3.8 % 180° 5 18 % 0° 2.4 % 180° 7 14 % 0° 1.7 % 180° 11 9 % 0° 1.0 % 180° 13 5 % 0° 0.8 % 180° Table 12 Peaked waveform Harmonic Current Current Voltage Voltage phase number amplitude phase angle amplitude Angle 1 100 % 0° 100 % 0° 3 30 % 180° 3.8 % 0° 5 18 % 0° 2.4 % 180° 7 14 % 180° 1.7 % 0° 11 9 % 180° 1.0 % 0° 13 5 % 0° 0.8 % 180°122 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)]
(vii) Tilt,–
Object of the test: To verify that the error shift due to tilt complies with the requirements of Table 4.This test is only for electromechanical meters or meters of other constructions that may be influenced by the working position.
Test procedure: The error shift, compared to the intrinsic error at the operating position given by the manufacturer, shall be measured when the meter is tilted from its ideal position to an angle 3° from that position.
Mandatory test The test shall, at minimum, be performed at I , PF = 1 and at two tr
points: perpendicular tilting angles.[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 123
(viii)Severe voltage variations,–
Object of the test: To verify that the error shift due to severe voltage variations complies with the requirements of Table 4.
Test procedure 1: The intrinsic error shall first be measured at U . It shall then be nom verified that the error shift, relative to the intrinsic error at U nom complies with the requirements of Table 4 when the voltage is varied from 0.8 U to 0.9 U and from 1.1 U to 1.15 U . For poly- nom nom nom nom phase meters, the test voltage shall be balanced. If several U nom values are stated, the test shall be repeated for each U value.
nom Mandatory test The test shall, at minimum, be performed at 10 I , PF =1 and for tr points 1: voltages of 0.8 U , 0.85 U and 1.15 U . nom nom nom Test procedure 2: Further, the error shift, compared to the intrinsic error at U , shall nom be measured when the voltage is varied from 0.8 U down to 0.
nom Mandatory test The test shall, at minimum, be performed at 10 I , PF = 1 and for tr points 2: voltages of 0.7 U , 0.6 U , 0.5 U , 0.4 U , 0.3 U , 0.2 U , nom nom nom nom nom nom
0.1 U , and 0 V. nom If the meter has a distinct shut-down voltage, then mandatory test points shall include one point above and one point below the shut-down voltage. The lower test point shall be within a 2 V range below the shut-down voltage. The upper test point shall be within a 2 V range above the turn-on voltage.
(ix) One or two phases interrupted,–
Object of the test: To verify that the error shift due to one or two phases interrupted complies with the requirements of Table 4. The test is only for poly- phase meters with three measuring elements.
Test procedure: The error shift, compared to the intrinsic error at balanced voltage and load current conditions, shall be measured when one or two of the phases are removed while keeping the load current constant. Two phases interrupted is only for those connection modes where a missing phase means that energy can be delivered. A poly-phase meter which is powered from only one of its phases shall not have the voltage of that phase interrupted for the purposes of this test.124 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] Mandatory test test shall, at minimum, be performed at 10 I , The with one or two tr
points: of the phases removed in combinations such that each phase has been removed at least once.
(x) Sub-harmonics in the AC current circuit,–
Object of the test: To verify that the error shift due to sub-harmonics complies with the requirements of Table 4.
Test procedure: The error shift, compared to the intrinsic error at sinusoidal conditions, shall be measured when the sinusoidal reference current is replaced by another sinusoidal signal with twice the peak value, and which is switched on and off every second period as shown by Figure 3 a) and b). (The measured power should then be the same as for the original sinusoidal signal while the r.m.s. current is 1.41 times higher). Care should be taken that no significant DC current is introduced. During the test, the peak value of the current shall not exceed 1.4 I .
max Mandatory test The test shall, at minimum, be performed at a reference current of
points: 10 I , PF = 1. tr[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 125
(xi) Harmonics in the AC current circuit,–
Object of the test: To verify that the error shift due to harmonics in the AC current circuit complies with the requirements of Table 4.
Test procedure: The error shift, compared to the intrinsic error at sinusoidal conditions, shall be measured when the sinusoidal reference current as shown in Figure 3 a) is replaced by a current with twice the original peak value where the sinusoidal waveform is set to zero during the first and third quarters of the period as shown by Figure 3 c). The measured power should then be the same as for the original sinusoidal signal while the r.m.s. current is 1.41 times higher. During the test, the peak value of the current shall not exceed
1.4 I . max Mandatory test The test shall, at minimum, be performed at a reference current of 10
points: I, PF = 1. Additional test points may be specified by Director (Legal tr Metrology).
(xii) Reversed phase sequence (any two phases interchanged),–
Object of the test: To verify that the error shift due to interchanging any two of the three phases complies with the requirements of Table 4. This test only applies to three-phase meters.
Test procedure: The error shift, compared to the intrinsic error at reference conditions, shall be measured when any two of the three phases are interchanged.
Mandatory test The test shall, at minimum, be performed at a reference current of 10
points: I, PF = 1 with any two of the three phases interchanged. Additional test tr points may be specified by Director (Legal Metrology).
(xiii) Continuous (DC) magnetic induction of external origin,–
Object of the test: To verify that the error shift due to continuous (DC) magnetic induction of external origin complies with the requirements of Table 4.
Test procedure: The error shift, compared to the intrinsic error at reference conditions, shall be measured when the meter is subjected to continuous magnetic induction with a probe in the form of a permanent magnet with a surface area of at least 2000 mm2. The magnetic field along the axis of the magnet’s core shall comply with details specified in Table 13 (1).
Note (1): A lower magnetic induction may be selected, if required.126 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] Table 13 Specifications of the field along axis of the magnet’s core Distance from Magnetic induction Tolerance magnet surface 30 mm 200 mt ± 30 mT Mandatory test 6 points per meter surface. The test shall, at minimum, be performed
points: at 10 I, PF = 1. The greatest error shift is to be noted as the test result. tr
Note: Neodymium or niobium permanent magnets may be used for this test.
(xiv) Magnetic field (AC, power frequency) of external origin,–
Object of the test: To verify that the error shift due to an AC magnetic field at power frequency complies with the requirements of Table 4.
Test procedure: The error shift, compared to the intrinsic error at reference conditions, shall be measured when the meter is exposed to a magnetic field at the power frequency (f = f ) under the most unfavorable condition of phase and nom direction.
Test severity: Continuous field, 400 A/m.
Mandatory test The test shall, at minimum, be performed at 10 I and at I , PF = 1. tr max
points:
(xv) Electromagnetic fields,–
(a) Radiated, radio frequency (RF), electromagnetic fields,–
Object of the test: To verify that the error shift due to radiated, radio frequency, electromagnetic fields complies with the requirements of Table 4. Meters such as electromechanical meters which have been constructed using only passive elements shall be assumed to be immune to radiated radiofrequency fields. Note, test condition 2 below corresponds to the disturbance test of 6.4.6.
Test procedure: The error shift, compared to the intrinsic error at sinusoidal conditions, shall be electromagnetic field strength shall be as specified by the severity level and the field uniformity shall be as defined by the standard referenced. The frequency ranges to be considered are swept with the modulated signal, pausing to adjust the RF signal level or to switch oscillators and antennas as necessary. Where the frequency range is swept incrementally, the step size shall not exceed 1 % of the preceding frequency value. The test time for a 1 % frequency change shall not be less than the time to make a measurement and in any case not less than 0.5 s.[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 127 The cable length exposed to the electromagnetic field shall be 1 m.
The test shall be performed with the generating antenna facing each side of the meter. When the meter can be used in different orientations (i.e. vertical or horizontal) all sides shall be exposed to the fields during the test.
The carrier shall be modulated with 80 % AM at 1 kHz sine wave.
The meter shall be separately tested at the manufacturer’s specified clock frequencies.
Any other sensitive frequencies shall also be analyzed separately.
Note: Usually these sensitive frequencies can be expected to be the frequencies emitted by the meter.
The meter shall be tested as a table-top instrument under two test conditions, where test condition 2 corresponds to the disturbance test of 6(4)(vi):
Test condition 1: During the test, the meter shall be energized with reference voltage and a current equal to 10 I. The measurement error of the meter shall be tr monitored by comparison with a reference meter not exposed to the electromagnetic field or immune to the field, or by an equally suitable method. The error at each 1 % incremental interval of the carrier frequency shall be monitored and compared to the requirements of Table 4. When using a continuous frequency sweep, this can be accomplished by adjusting the ratio of the sweep time and the time of each measurement. When using incremental 1 % frequency steps, this can be accomplished by adjusting the dwell time on each frequency to fit the measurement time.
Test condition 2: During the test, the voltage and auxiliary circuits of the meter shall be energized with reference voltage. There should be no current in the current circuits and the current terminals shall be open-circuited.
Note: Test condition 2 corresponds to the disturbance test of 6(4)(vi), therefore the general instructions of 6(4)(i) also apply.
Test severities: As defined in Table 14.
Table 14 Severity of test For test condition Frequency range Field strength Test condition 1 (with 80 – 6000 MHz 10 V/m current) Test condition 2 80 – 6000 MHz 30 V/m (without current)128 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)]
(b) Immunity to conducted disturbances, induced by radiofrequency fields,-
Object of the test: To verify that the error shift due to conducted disturbances, induced by RF fields complies with the requirements of Table 4. Meters such as electromechanical meters which have been constructed using only passive elements shall be assumed to be immune to conducted disturbances induced by RF fields.
Test procedure: A radiofrequency electromagnetic current to simulate the influence of electromagnetic fields shall be coupled or injected into the power ports and I/O ports of the meter using coupling/decoupling devices as defined in the standard referenced. The performance of the test equipment consisting of an RF generator, (de)coupling devices, attenuators, etc. shall be verified.
The meter shall be tested as a table-top instrument. During the test, the meter shall be energized with reference voltage and a current equal to 10 I. The error at each 1 % incremental interval of the carrier frequency shall tr be monitored and compared to the requirements of Table 4. When using a continuous frequency sweep, this can be accomplished by adjusting the ratio of the sweep time and the time of each measurement. When using incremental 1 % frequency steps, this can be accomplished by adjusting the dwell time on each frequency to fit the measurement time.
If the meter is a poly-phase meter, the tests shall be performed at all extremities of the cable.
Test severity: RF amplitude (50 Ohm): 10 V (e.m.f.)
Frequency range: 0.15 – 80 MHz
Modulation: 80 % AM, 1 kHz sine wave
(xvi) DC in the AC current circuit,-
Object of the test: To verify that the error shift due to DC in the AC current circuit complies with the requirements of Table 4. Electromechanical and transformer operated meters shall be assumed to be immune to DC in the AC current circuit.
Test procedure: The error shift, compared to the intrinsic error at sinusoidal conditions at I =I /2 , shall be measured when the current amplitude is increased to max twice its value ( I =I 2 ) and is half-wave rectified. Mandatory test max
points: The test shall be performed at PF = 1.
Note 1: The half-wave rectification and measurement can be performed as shown in Figure 4 (only the current path is shown, the voltage shall be connected as normal). The uncertainty of[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 129 measurement in this method is very dependent on the (sub-period) output impedance of the current source and the current circuit impedance of the standard meter in combination with the possible impedance differences of the two current branches.
Note 2: Since the uncertainty is dependent on the absolute branch impedance difference and not the relative (if not R >> R ), the problem can generally not be remedied by balancing source introducing additional matched resistors in each branch. It can, however, be monitored by studying the DC current from the source. The DC components should not be higher than 0.5 to 1 % of the AC value. (When measuring a DC component in the order of 1 % of the AC component, the instrument should preferably be calibrated beforehand by a measurement of the test current with the test circuit diodes disconnected and short-circuited.)
(xvii) High-order harmonics,-
Object of the test: To verify that the error shift due to high-order harmonics complies with the requirements of Table 4. Furthermore, the function of the meter shall not be impaired.
Test procedure: The error shift, compared to the intrinsic error at sinusoidal conditions, shall be measured when asynchronous test signals, swept from f = 15 f to 40 nom f , are superimposed first on the signal to the voltage circuits and then on nom the signal to the current circuits. In the case of a poly-phase meter all voltage or current circuits may be tested at the same time. The signal frequency shall be swept from low frequency to high frequency and back down while the metering error is measured.
Test severity: The asynchronous signal shall have a value of 0.02 U and 0.1 I, with a nom tr tolerance of ± 5 %.
Mandatory test The test shall be performed at I. One reading shall be taken per tr
points: harmonic frequency.
(4) Tests for disturbances,-
(i) General instructions for disturbance tests.- These tests are to verify that the meter fulfils the requirements for the influence of disturbances as given by Table 5. Tests are to be performed using one disturbance at a time; all other influence quantities shall be set to reference conditions unless otherwise stated in the relevant test description. No significant fault shall occur. Unless otherwise stated, each test shall include130 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] a) a check that any change in the registers or equivalent energy of the test output is less than the critical change value given in 3(3)(vi)(b), b) an operational check to verify that the meter registers energy when subjected to current, c) a check for correct operation of pulse outputs and tariff change inputs, if present, and d) confirmation by measurement that the meter still fulfils the base maximum permissible error requirements after the disturbance test.
Temporary loss of functionality is allowed as long as the meter returns to normal functionality automatically when the disturbance is removed.
The mandatory test points for checking the base maximum permissible error are
1) I, PF = 1, tr
2) 10 I, PF = 0.5 inductive. tr
(ii) Magnetic field (AC, power frequency) of external origin,-
Object of the test: To verify compliance with the requirements of 3(3)(vi)(b) and Table 5 under conditions of an AC magnetic field at power frequency of external origin.
Test procedure: The meter shall be connected to the reference voltage but with no current in the current circuits. The magnetic field shall be applied along three orthogonal directions.
Allowed effects: No significant fault shall occur.
Test severity: Magnetic field strength short duration (3 s): 1000 A/m.
(iii) Electrostatic discharge,-
Object of the test: To verify compliance with the requirements of 3(3)(vi)(b) and Table 5 under conditions of direct and indirect electrostatic discharge. Meters such as electromechanical meters which have been constructed using only passive elements shall be assumed to be immune to electrostatic discharges.
Test procedure: An ESD generator shall be used with performance characteristics specified in the referenced standard. Before starting the tests, the performance of the generator shall be verified. At least 10 discharges, in the most sensitive polarity, shall be applied. For a meter not equipped with a ground terminal, the meter shall be fully discharged between discharges. Contact discharge is the preferred test method. Air discharges shall be used where contact discharge cannot be applied.
Direct application: In the contact discharge mode to be carried out on conductive surfaces, shall be in contact with the meter. In the air discharge mode on insulated surfaces, the electrode is approached to the meter and the discharge occurs by spark.[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 131
Indirect application: The discharges are applied in the contact mode to coupling planes mounted in the vicinity of the meter.
Test conditions: The test shall be done with the meter in operating condition. The voltage circuits shall be energized with U and the current and auxiliary circuits nom shall be open, without any current. The meter shall be tested as table-top equipment.
Allowed effects: No significant fault shall occur.
Test severity: Contact discharge voltage (1): 8 kV Air discharge voltage (2): 15 kV Note (1): Contact discharges shall be applied on conductive surfaces.
Note (2): Air discharges shall be applied on non-conductive surfaces.
(iv) Fast transients,-
Object of the test: To verify compliance with the requirements of 3(3)(vi)(b) and Table 5 under conditions where electrical bursts are superimposed on voltage and current circuits, and I/O and communication ports. Meters such as electromechanical meters which have been constructed using only passive elements shall be assumed to be immune to fast transients.
Test procedure: A burst generator shall be used with the performance characteristics specified in the referenced standard. The meter shall be subjected to bursts of voltage spikes for which the repetition frequency of the impulses and peak values of the output voltage on 50 Ohm and 1000 Ohm loads are defined in the referenced standard. The characteristics of the generator shall be verified before connecting the meter. Both positive and negative polarity bursts shall be applied. The duration of the test shall not be less than 1 min for each amplitude and polarity. A capacitive coupling clamp, as defined in the standard, shall be used to couple to I/O and communication lines with a reference voltage over 40 V. The test pulses shall be applied continuously during the measurement time.
Test conditions: The meter shall be tested as table-top equipment.
The meter voltage and auxiliary circuits shall be energized with reference voltage.
The cable length between the coupling device and the meter shall be 1 m.
The test voltage shall be applied in common mode (line-to-earth) to a) the voltage circuits, b) the current circuits, if separated from the voltage circuits in normal operation,132 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] c) the auxiliary circuits, if separated from the voltage circuits in normal operation and with a reference voltage over 40 V.
Test severity: Test voltage on the current and voltage circuits: 4 kV.
Test voltage on auxiliary circuits with a reference voltage over 40 V: 2 kV.
Allowed effects: The error shift, compared to the intrinsic error at reference conditions, shall be less than that given for the relevant meter class in Table 5.
Mandatory test points: 10 I, PF = 1. tr
(v) Voltage dips and interruptions,-
Object of the test: To verify compliance with the requirements of 3(3)(vi)(b) and Table 5 under conditions of short time mains voltage reductions (dips and interruptions).
Meters such as electromechanical meters which have been constructed using only passive elements shall be assumed to be immune to voltage dips and interruptions.
Test procedure: A test generator, which is able to reduce the amplitude of the AC mains voltage over an operator-defined period of time, should be used in this test.
The performance of the test generator shall be verified before connecting the meter.
The mains voltage reductions shall be repeated 10 times with an interval of at least 10 seconds.
Test conditions: Voltage circuits energized with U . nom Without any current in the current circuits.
Test severities: Voltage dips:
Test Test a Test b Test c
Reduction: 30 % 60 % 60 %
Duration: 0.5 cycles 1 cycle 25 cycles (50 Hz) 30 cycles (60 Hz)
Voltage interruption test:
Reduction: 0 %
Duration: 250 cycles (50 Hz) 300 cycles (60 Hz)
Allowed effect: No significant fault shall occur.
(vi) Radiated, radio frequency (RF), electromagnetic fields,-
Object of the test: To verify compliance with the requirements of 3(3)(vi)(b) and Table 5 under conditions of radiated, radio frequency, electromagnetic fields. Meters such as electromechanical meters which have been constructed using only[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 133 passive elements shall be assumed to be immune to radiated radiofrequency fields.
Test procedure: Refer to 6(3)(xv)(a) for test procedure.
Allowed effects: No significant fault shall occur.
(vii) Surges on AC mains power lines,-
Object of the test: To verify compliance with the requirements of 3(3)(vi)(b) and Table 5 under conditions where electrical surges are superimposed on the mains voltage and, if applicable, on I/O and communication ports. This test is not applicable for meters such as electromechanical meters which shall be assumed to be immune to surges.
Test procedure: A surge generator shall be used with the performance characteristics specified in the referenced standard. The test consists of exposure to surges for which the rise time, pulse width, peak values of the output voltage/current on high/low impedance load, and minimum time interval between two successive pulses are defined in the referenced standard.
The characteristics of the generator shall be verified before connecting the meter.
Test conditions: Meter in operating condition;
Voltage circuits energized with nominal voltage;
Without any current in the current circuits and the current terminals shall be open;
Cable length between surge generator and meter: 1 m;
Tested in differential mode (line to line);
Phase angle: pulses to be applied at 60° and 240° relative to zero crossing of AC supply.
Test severities: Voltage circuits: • Line to line: Test voltage: • 2.0 kV, generator source; impedance: 2 Ω; • Line to earth(1): Test voltage: 4.0 kV; generator source; impedance: 2 Ω; • Number of tests: 5 positive and 5 negative;
• Repetition rate: maximum 1/min.
Auxiliary circuits with a reference voltage over 40 V: • Line to line: Test voltage: • 1.0 kV, generator source; impedance: 42 Ω; • Line to earth(1): Test voltage: 2.0 kV; generator source; impedance: 42 Ω;
• Number of tests: 5 positive and 5 negative; • Repetition rate: maximum 1/min.
Note (1): For cases where the earth of the meter is separate to neutral.134 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)]
(viii) Damped oscillatory waves immunity test,-
Object of the test: To verify compliance with the requirements of 3(3)(vi)(b) and Table 5 under conditions of damped oscillatory waves. This test is only for meters intended to be operated with voltage transformers.
Test procedure: The meter is subjected to damped oscillatory voltage waveforms with a peak voltage according to the test severity stated below.
Test conditions: Meters shall be tested as table-top equipment;
Meters shall be in operating condition;
Voltage circuits energized with nominal voltage;
With I = 20 I and power factor one and 0.5 inductive. tr
Test severities: Test voltage on voltage circuits and auxiliary circuits with an operating voltage > 40 V: • common mode: 2.5 kV; • differential mode: 1.0 kV;
Test frequencies: • 100 kHz, repetition rate: 40 Hz; • 1 MHz, repetition rate: 400 Hz;
Test duration: 60 s (15 cycles with 2 s on, 2 s off, for each frequency).
Allowed effects: During the test the function of the meter shall not be perturbed and the error shift shall be less than the limits given in Table 5.
Mandatory test points: 20 I, PF = 1 and 0.5 inductive. tr
(ix) Short-time overcurrent,-
Object of the test: To verify compliance with the requirements of 3(3)(vi)(b) and Table 5 under conditions of a short time over current.
Test procedure: The meter shall be able to handle the current caused by a short-circuit within the load being metered, when that load is protected with the proper fuses or breakers.
Test current: For direct connected meters: 30·I +0 % –10 %, for one half cycle at max rated frequency or equivalent. For meters connected through current
transformers:
A current equivalent to 20·I +0 % –10 %, for 0.5 s. max The test current shall be applied to one phase at the time. The test current value given is the r.m.s. value, not the peak value.
Allowed effects: No damage shall occur. With the voltage reconnected the meter shall be allowed to return to normal temperatures (about 1 h). The error shift, compared to the initial error before the test, shall then be less than the limit of error shift given by Table 5.
Mandatory test points: 10 I, PF = 1. tr[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 135
(x) Impulse voltage,-
(a) General,-
Object of the test: To verify compliance with the requirements of 3(3)(vi)(b) and Table 5 under conditions of impulse voltage.
General test The meter and its incorporated ancillary devices, if any, shall be such
procedure: that they retain adequate dielectric qualities, taking account of the atmospheric influences and different voltages to which they are subjected under normal conditions of use.
The meter shall withstand the impulse voltage test as specified below. The test shall be carried out only on complete meters.
For the purpose of this test, the term “earth” has the following meaning: a) when the meter case is made of metal, the “earth” is the case itself, placed on a flat, conducting surface; b) when the meter case or only part of it is made of insulating material, the “earth” is a conductive foil wrapped around the meter touching all accessible conductive parts and connected to the flat, conducting surface on which the meter is placed. The distances between the conductive foil and the terminals, and between the conductive foil and the holes for the conductors, shall be no more than 2 cm.
During the impulse voltage test, the circuits that are not under test shall be connected to the earth.
General test Ambient temperature: 15 °C to 25 °C;
conditions: Relative humidity: 25 % to 75 %;
Atmospheric pressure: 86 kPa to 106 kPa.
Allowed effects: After completion of the impulse voltage test, there shall be no damage to the meter and no significant fault shall occur.
(b) Impulse voltage test procedure,-
Test conditions: Impulse waveform: 1.2/50 µs impulse
Voltage rise time: ± 30 %;
Voltage fall time: ± 20 %;
Source energy: 10.0 J ± 1.0 J;
Test voltage: in accordance with Table 15;
Test voltage tolerance: +0 –10 %.
Note: The selection of the source impedance is at the discretion of the testing laboratory.
For each test (see 6(4)(x)(c) and 6(4)(x)(d)) the impulse voltage is applied ten times with one polarity and then repeated ten times with the other polarity. The minimum time between impulses shall be 30 s.136 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] Table 15 Impulse voltage test levels Voltage phase to earth derived Rated impulse voltage (V) from rated system voltage (V) V ≤100 3000 100 < V ≤150 6000 150 < V ≤300 10000 300 < V ≤600 12000
(c) Impulse voltage tests for circuits and between circuits,-
Test procedure: The test shall be made independently on each circuit (or assembly of circuits) which is insulated from other circuits of the meter in normal use.
The terminals of the circuits which are not subjected to impulse voltage shall be connected to earth.
Thus, when the voltage and current circuits of a measuring element are connected together in normal use, the test shall be made on the whole. The other end of the voltage circuit shall be connected to earth and the impulse voltage shall be applied between the terminal of the current circuit and earth. When several voltage circuits of a meter have a common point, this point shall be connected to earth and the impulse voltage successively applied between each of the free ends of the connections (or the current circuit connected to it) and earth. The other end of this current circuit shall be open.
When the voltage and current circuits of the same measuring element are separated and appropriately insulated in normal use (e.g. each circuit connected to measuring transformer), the test shall be made separately on each circuit.
During the test of a current circuit, the terminals of the other circuits shall be connected to earth and the impulse voltage shall be applied between one of the terminals of the current circuit and earth. During the test of a voltage circuit, the terminals of the other circuits and one of the terminals of the voltage circuit under test shall be connected to earth and the impulse voltage shall be applied between the other terminal of the voltage circuit and earth.
The auxiliary circuits intended to be connected either directly to the mains or to the same voltage transformers as the meter circuits, and with a reference voltage over 40 V, shall be subjected to the impulse voltage test by being tied together with a voltage circuit during tests. The other auxiliary circuits shall not be tested.
(d) Impulse voltage test of electric circuits relative to earth,-[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 137
Test procedure: All the terminals of the electric circuits of the meter, including those of the auxiliary circuits with a reference voltage over 40 V, shall be connected together.
The auxiliary circuits with a reference voltage below or equal to 40 V shall be connected to earth. The impulse voltage shall be applied between all the electric circuits and earth.
Allowed effects: During this test no flashover, disruptive discharge or puncture shall occur.
(xi) Earth fault,-
Object of the test: To verify compliance with the provisions of 3(3)(vi)(b) and Table 5 under conditions of earth fault.
This test only applies to three-phase four-wire transformer-operated meters connected to distribution networks which are equipped with earth fault neutralizers or in which the star point is isolated. In the case of an earth fault and with 10 % overvoltage, the line-to-earth voltages of the two lines which are not affected by the earth fault will rise to 1.9 times the nominal voltage.
Test procedure: The following test requirements apply:
For a test under a simulated earth fault condition in one of the three lines, all voltages are increased to 1.1 times the nominal voltages during 4 h. The neutral terminal of the meter under test is disconnected from the ground terminal of the meter test equipment (MTE) and is connected to the MTE's line terminal at which the earth fault has to be simulated (see Figure 5).
In this way, the two voltage terminals of the meter under test which are not affected by the earth fault are connected to 1.9 times the nominal phase voltages.
Allowed effects: After the test, the meter shall show no damage and shall operate correctly.
The change of error measured when the meter is back at nominal working temperature shall not exceed the limits given in Table 5.
Mandatory test points: 10 I , power factor = 1, balanced load. tr138 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)]
(xii) Operation of ancillary devices,-
Object of the test: To verify compliance with the provisions of 3(3)(vi)(b) and Table 5 under conditions of operation of ancillary devices. The operation of ancillary devices shall be tested to ensure that they do not affect the metrological performance of the meter.
Test procedure: In this test, the meter shall be operated at reference conditions and its error continuously monitored, while ancillary devices such as communication devices, relays and other I/O circuits are operated.
Allowed effects: The functionality of the meter shall not be impaired and the error shift due to the operation of the ancillary devices shall always be less than the error shift limit specified in Table 5.
Mandatory test I and I at PF = 1. tr max
points:
(xiii) Mechanical tests,-
(a) Vibrations,-
Object of the test: To verify compliance with the provisions of 3(3)(vi)(b) and Table 5 under conditions of vibrations.
Test procedure: The meter shall, in turn, be tested in three, mutually perpendicular axes whilst mounted on a rigid fixture by its normal mounting means.
The meter shall normally be mounted so that the gravitational force acts in the same direction as it would in normal use. Where the effect of gravitational force is not important the meter may be mounted in any position.[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 139
Test severity:
Total frequency range 10 – 150 Hz Total r.m.s. level 7 m·s–2 Acceleration Spectral Density (ASD) 1 m2·s–3 level 10 – 20 Hz Acceleration Spectral Density (ASD) –3 dB/octave level 20 – 150 Hz
Duration per axis: at least 2 min.
Allowed effects: After the test, the function of the meter shall not be impaired and the error shift, at10 I, shall not exceed the limit of error shift listed in Table 5. tr Mandatory test 10 I, PF = 1.
tr
Points:
(b) Shock,-
Object of the test: To verify compliance with the provisions of 3(3)(vi)(b) and Table 5 under conditions of shock.
Test procedure: The meter is subjected to non-repetitive shocks of standard pulse shapes with specified peak acceleration and duration. During the test, the meter shall not be operational and it shall be fastened to a fixture or to the shock- testing machine.
Test severity: Pulse shape: half-sine;
Peak acceleration: 30 g (300 ms-2); n
Pulse duration: 18 ms.
Allowed effects: After the test, the function of the meter shall not be impaired and the error shift, at10 I, shall not exceed the limit of error shift listed in Table 5. tr
Mandatory test points: 10 I, PF = 1. tr
(xiv) Protection against solar radiation,-
Object of the test: To verify compliance with the requirements of 3(5), 3(6)(i), 3(7)(i) and 3(3)(vi)(b) regarding protection against solar radiation. For outdoor meters only.
Test conditions: Meter in non-operating condition.
Test apparatus: Lamp type/wavelength: UVA 340;
Black panel thermometer;
Light meter;
Cycling rig with a condensation cycle to comply with the parameters in the test conditions.
Test conditions: Meter in non-operating condition140 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] Test cycle (12 h Lamp type Spectral Black panel cycle) irradiance temperature 8 h dry UVA 340 0.76 W·m–2· nm–1 60 ± 3 °C at 340 nm 4 h condensation Light off 50 ± 3 °C
Test procedure in brief: Partially mask a section of the meter for later comparison. Expose the meter to artificial radiation and weathering for a period of 66 days (132 cycles) and in accordance with the test conditions above.
After the test the meter shall be visually inspected and a functional test shall be performed. The appearance and, in particular, the legibility of markings and displays shall not be altered. Any means of protection of the metrological properties, such as the case and sealing, shall not be affected. The function of the meter shall not be impaired.
(xv) Protection against ingress of dust,-
Object of the test: To verify compliance with the provisions of 3(3)(vi)(b) and Table 5 regarding protection against the ingress of dust.
Test conditions: Reference conditions;
IP 5X rating;
Category 2 enclosure.
Test procedure: After the test the interior of the meter shall be visually inspected and a functional test shall be performed.
Allowed effects: The talcum powder or other dust used in the test shall not have accumulated in a quantity or location such that it could interfere with the correct operation of the equipment or impair safety. No dust shall deposit where it could lead to tracking along the creepage distances. The function of the meter shall not be impaired.
(xvi) Climatic tests,-
(a) Extreme temperatures - dry heat,-
Object of the test: To verify compliance with the provisions of 3(3)(vi)(b) and Table 5 under conditions of dry heat.
Test procedure: The test consists of exposure to the specified high temperature under “free air” conditions for 2 h (beginning from when the temperature of the meter is stable), with the meter in a non-operating state.
The change of temperature shall not exceed 1 °C/min during heating up and cooling down.
The absolute humidity of the test atmosphere shall not exceed 20 g/m3.[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 141
Test severity: The test shall be performed at a standard temperature one step higher than the upper temperature limit specified for the meter.
Possible temperatures: 40 °C 55 °C 70 °C 85 °C.
Allowed effects: After the test, the function of the meter shall not be impaired and the error shift shall not exceed the limit of error shift listed in Table 5.
Mandatory test points: 10 I, PF = 1. tr
(b) Extreme temperatures – cold,-
Object of the test: To verify compliance with the provisions of 3(3)(vi)(b) and Table 5 under conditions of low temperatures.
Test procedure: The test consists of exposure to the specified low temperature under “free air” conditions for 2 h (beginning from the time when the temperature of the meter is stable) with the meter in a non-operating state.
The change of temperature shall not exceed 1 °C/min during heating up and cooling down.
Test severity: The test shall be performed at a standard temperature one step lower than the lower temperature limit specified for the meter.
Possible temperatures: –10 °C –25 °C –40 °C –55 °C(1).
Allowed effects: After the test, the function of the meter shall not be impaired and the error shift shall not exceed the limit of error shift listed in Table 5.
Mandatory test points: 10 I, PF = 1. tr Note (1): If specified lower temperature limit is –55 ºC, then this test shall be performed at –55 ºC.
(c) Damp heat, steady-state (non-condensing), for humidity class H1,-
Object of the test: To verify compliance with the provisions in Table 4, 3(3)(vi)(b) and Table 5 under conditions of high humidity and constant temperature. For meters that are specified for enclosed locations where the meters are not subjected to condensed water, precipitation, or ice formations (H1).
Test procedure: The test consists of exposure to the specified high level temperature and the specified constant relative humidity for a certain fixed time defined by the severity level. The meter shall be handled such that no condensation of water occurs on it.
Test conditions: Voltage and auxiliary circuits energized with reference voltage;
Without any current in the current circuits.142 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)]
Test severity: Temperature: 30 °C;
Humidity: 85 %;
Duration: 2 days.
Allowed effects: During the test no significant fault shall occur. Immediately after the test the meter shall operate correctly and comply with the accuracy requirements of Table 4.
24 h after the test the meter shall be submitted to a functional test during which it shall be demonstrated to operate correctly. There shall be no evidence of any mechanical damage or corrosion which may affect the functional properties of the meter.
(d) Damp heat, cyclic (condensing) for humidity class H2 and H3,-
Object of the test: To verify compliance with the provisions in Table 4, 3(3)(vi)(b) and Table 5 under conditions of high humidity and temperature variations. This test applies to meters with a humidity class specification either for enclosed locations where meters can be subjected to condensed water or for open locations (humidity classes H2 and H3).
Test procedure: The test consists of exposure to cyclic temperature variation between 25 °C and the temperature specified as the upper temperature according to the test severities below, whilst maintaining the relative humidity above 95 % during the temperature change and low temperature phases, and at 93 % during the upper temperature phases.
Condensation should occur on the meter during the temperature rise.
The 24 h cycle consists of
1) temperature rise during 3 h,
2) temperature maintained at upper value until 12 h from the start of the cycle,
3) temperature reduced to lower value within 3 h to 6 h, the rate of fall during the first hour and a half being such that the lower value would be reached in 3 h,
4) temperature maintained at lower value until the 24 h cycle is completed.
The stabilizing period before and recovery after the cyclic exposure shall be such that all parts of the meter are within 3 °C of their final temperature.
Test conditions: Voltage and auxiliary circuits energized with reference voltage;
Without any current in the current circuits;
Mounting position according to manufacturer’s specification.
Test severities: Meters with a humidity class specification for enclosed locations where meters can be subjected to condensed water shall be tested at severity level
1. Meters with a humidity class specification for open locations shall be tested at severity level 2.[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 143
Specified humidity class: H2 H3
Severity levels: 1 2 Upper temperature (°C): 40 55 Duration (cycles): 2 2
Allowed effects: During the test no significant fault shall occur.
Immediately after the test the meter shall operate correctly and comply with the accuracy requirements of Table 4.
24 h after the test the meter shall be submitted to a functional test during which it shall be demonstrated to operate correctly. There shall be no evidence of any mechanical damage or corrosion which may affect the functional properties of the meter.
(e) Water test,-
Object of the test: To verify compliance with the provisions in 3(3)(vi)(b) and Table 5 under conditions of rain and water splashes. The test is applicable to meters that are specified for open locations (H3).
Test procedure: The meter is mounted on an appropriate fixture and is subjected to impacting water generated from either an oscillating tube or a spray nozzle used to simulate spraying or splashing water.
Test conditions: The meter shall be in functional mode during the test;
Flow rate (per nozzle): 0.07 L/min;
Duration: 10 min;
Angle of inclination: 0° and 180°.
Allowed effects: During the test no significant fault shall occur.
Immediately after the test the meter shall operate correctly and comply with the accuracy requirements of Table 2.
24 h after the test the meter shall be submitted to a functional test during which it shall be demonstrated to operate correctly and comply with the accuracy requirements of Table 2. There shall be no evidence of any mechanical damage or corrosion which may affect the functional properties of the meter.
(xvii) Durability test,-
Object of the test: To verify compliance with the provisions in 3(8) and Table 5 for durability.
Test procedure: Test shall be performed to check durability of electricity meters.144 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)]
Mandatory test points: For initial and final measurement, the voltage shall be U , with the nom
following test points: I, 10 I, and I at PF = 1. tr tr max
7. Type evaluation and approval.- An examination for type evaluation shall determine whether a meter complies with all requirements in Clause 3 and whether documentation supplied by the manufacturer complies with the requirements in clause 4(1).
A meter may only be deemed to have passed examination for type approval if the results of all type tests comply with the requirements given in clause 3. The measurement uncertainty shall be small enough to allow clear discrimination between a pass result and a fail result. In particular, an uncertainty less than one fifth the maximum permissible error given for the corresponding test point must be obtained for tests described in clause 6(2), unless otherwise specified in the relevant test description.
The scope of the tests performed and test severities used shall be consistent with the manufacturer’s specifications and with the requirements of clause 3.
8. Verification,-
(1) General.- Verification may be carried out individually. In all cases meters shall conform to the requirements of this Notification. The base maximum permissible errors for subsequent verification and in-service inspections shall be the same as given in 3(3)(iii). The initial verification of all meters and re-verification of those meters which have been repaired or otherwise changed shall be done. The re-verification period of in-service meters shall be given
in Table A and B as follows:
Table A Electro-mechanical induction-type Colum Column II n I Type Re-verification Period
1. Electrical Energy Meters – watt-hour, reactive-volt-ampere-hour, volt-ampere-hour, or Q- hour, including those with integrated pulse initiators, multi-tariff registers, remote-meter- reading or automatic-meter-reading (AMR) features.
Disk-suspension type Magnetic Other a) 1- or 1½-element, standard A 5 years 2 years or S base b) 2-, 2½-, or 3-element 3 years 2 years c) Totalizing types 2 years 2 years
2. Loss meter a) A²-hour 2 years b) V²-hour 2 years[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 145
3. Electrical Demand (Power) Meters – watt, reactive-volt-ampere or volt-ampere including those with integrated energy meters and associated functions a) Mechanical block-interval 2 years b) Thermal or recti-thermal 2 years
4. Other meters a) Magnetic-tape Pulse-recorder 3 years b) Punched-paper Pulse-recorder 3 years c) Electronic Pulse-recorder 2 years d) Thermal converters 3 years e) Transducers 3 years f) Electronic Instrument 3 years Transformers Table B Electronic-type Column I Column II Type Re-verification Period
5. Electrical Energy Functions– watt-hour, reactive-volt-ampere-hour, volt-ampere-hour, Q- hour, A²hour, V²hour including those with integrated pulse initiators and/or receivers, multi- tariff registers, remote-meter-reading or automatic-meter-reading (AMR) features.
a) single-phase types 3 years b) polyphase types 3 years
6. Electrical Demand (Power) Functions– watt, reactive-volt-ampere or volt-ampere including those with integrated energy meters and associated functions a) single-phase types 3 years b) polyphase types 3 years
(2) Testing.-
(i) Calibration status.- Check that the test system used has sufficient accuracy to verify the meters under test, and that the calibration is valid.
(ii) Conformity check.- Check that the instrument is manufactured in conformity with the type approval documentation.
(iii) Warming-up.- It may be necessary to warm the meter up before full operation. The length of the warming-up period depends on the actual type of instrument and shall be determined in advance. During the test for initial intrinsic error the meter shall be allowed to stabilize at each current level before measurements for a period, no longer than 5 min, to be nominated by the146 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] manufacturer. The order of the test points shall be from lowest current to highest current and then from highest current to lowest current. For each test point, the resulting error shall be the mean of these measurements. For I , the maximum measurement time shall be 10 min max including stabilizing time.
(iv) Minimum test program.- The minimum program consists of: • No-load check; • Starting current check; • Current dependence; • Check of the register.
(a) No-load check.- For this test, there shall be no current in the current circuit. The test shall be performed at U . nom For meters with a test output, the output of the meter shall not produce more than one pulse.
For an electromechanical meter, the rotor of the meter shall not make a complete revolution.
The minimum test period ∆t shall be as specified period in 6(2)(iv).
A meter with more than one connection mode shall be tested in all modes. However, if the test is made in-situ on an installed meter, only the actual mode of connection need be tested.
For transformer-operated meters with primary rated registers where the value of k (and possibly U ) are given as primary side values, the constant k (and U ) shall be recalculated to nom nom correspond to secondary side values (of voltage and current).
(b) Starting current check.- The test is performed at I and unity power factor. st For initial verification of meters produced from a continuously operating process resulting in a large number of identical units, it is sufficient for the error curve from I to I to be recorded st min on a sample batch every 3 months for the particular meter type.
For initial verification of meters produced by other means, it will be sufficient if the meter is observed to run continuously when the starting current is applied (refer to the test procedure in 6(2)(iii)).
A meter with more than one connection mode shall be tested in all modes. However, if the test is made in-situ on an installed meter, only the actual mode of connection need be tested.
(c) Current dependence.- Meters shall comply with the accuracy requirements of Table 2. As a
minimum these shall be checked at the following currents: • I , PF = 1; min • I , PF = 1; tr • I , PF = 0.5 inductive; tr • 10 I , PF = 1; tr • 10 I , PF = 0.5 inductive; tr • I , PF = 1; max[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 147 • I , PF = 0.5 inductive.
max In the case of three-phase meters with an alternative single-phase connection mode or which are being used as two-phase meters, the single-phase load test shall be performed separately
for each phase at: • 10 I , PF = 1; and tr • 10 I , PF = 0.5 inductive. tr For meters with alternate connection modes, such as one-phase connections for poly-phase meters or meters being used as two-phase meters, this test shall be performed separately for each connection mode.
(d) Check of the register.- If test (pulse) outputs are used for tests of accuracy requirements, a test must be performed to ensure that the relation between the basic energy register and the r elevant test output(s) complies with that specified by the manufacturer.
The test shall be performed by passing a quantity of energy E through the meter, where E ≥E min specified in 6(2)(v):
The energy put through the meter shall be calculated using the number of pulses from the test output; the relative difference between this energy and the energy registered shall be determined. This relative difference must not be greater than one tenth of the base maximum permissible error.
The test shall be performed at a single arbitrary current I ≥I. tr
(v) Sealing.- If there are no seals on the meter (e.g. because they have not yet been applied or because they have been removed during verification testing), the meter shall be sealed.
(3) Reference conditions for initial and subsequent verifications in a laboratory.- Reference conditions and load conditions for initial and subsequent verifications in a laboratory are given in Tables 16 and 17.
Table 16 Reference conditions and their tolerances for initial and subsequent verification Quantity Reference conditions Tolerance Voltage(s) U ± 2 % nom Ambient temperature 23 ºC ± 5 ºC Frequency F ± 0.5 % nom Wave-form Sinusoidal d ≤ 2% Magnetic induction of 0 T B ≤ 0.1 mT external origin at reference frequency Electromagnetic RF fields 0 V/m < 2 V/m 30 kHz – 6 GHz Operating position for Mounting as stated by ± 3.0º instruments sensitive to manufacturer position Phase sequence for poly- L1, L2, L3 - phase meters148 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] Equal current in all ± 5 % and ± 5º Load balance current circuits Table 17 Load conditions and their tolerances in tests for initial and subsequent verification Current range of device under Class A, B: ± 10 % Current(s) test Class C, D: ± 10 % Power factor range of device current to voltage phase Power factor under test difference ± 5º 'ANNEXURE- A’ Estimation of combined errors
(Informative)
(1) Estimate of combined maximum permissible error based on the requirements of this
Notification This Notification permits a base maximum permissible error plus an error shift caused by influence quantities. The actual error of a complying meter when in use could therefore exceed the base maximum permissible error. There is a need to estimate an overall maximum permissible error that indicates the largest error that can reasonably be attributed to a meter type that complies with this Notification. This entails estimating the errors of a measurement of an arbitrary meter within the rated operating conditions.
However, adding the base maximum permissible error and all error shifts algebraically would give a much too pessimistic estimate of the metering uncertainty, for two reasons. For an arbitrary set of influence factor values, some of the error shifts will be low and some will probably have opposite signs, tending to cancel each other out. Furthermore, the electricity meter is an integrating device, thus the errors caused by influence quantities will average out to some extent as the values of the influence factors vary over time.
If we make the following assumptions: a) the integrating effect may be ignored, b) none of the effects of the influence factors are correlated;, c) the values of the influence quantities are more likely to be close to the reference values than to limits of the rated operated conditions,[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 149 d) the influence quantities, and the effects of the influence factors, can be treated as Gaussian distributions, and thus a value of half the maximum permissible error shift can be used for the standard uncertainty, then the combined maximum permissible error (assuming a coverage factor of two corresponding to a coverage probability of approximately 95 %) can be estimated
using the formula: v =2* where V is the base maximum permissible error; base V is the maximum error shift permitted for voltage variation; voltage V is the maximum error shift permitted for frequency variation;
frequency V is the maximum error shift permitted for unbalance variation; unbalance V is the maximum error shift permitted for the variation of harmonic content; harmonics V is the maximum error permitted for temperature variation.
temperature
(2) Estimation of combined error based on type test results and specific conditions
(i) Method 1 The combined maximum error can also be estimated for a particular meter type using type test results. Type test results can often show a smaller variation than that required by this
Notification, leading to an assured smaller value for the overall maximum error.
Keeping the assumption of a Gaussian distribution being valid the combined maximum error can then be estimated from a combination of test results using the formula (3):
where:
For each current I and each power factor PF i p • e(PF , I ) is the intrinsic error of the meter measured in the course of the tests, at current P i I and power factor PF; i p • δe (T ) , δe (U ) , δe ( f ) are the maximum additional errors measured in the course p,i p,i p,i the test, when the temperature, the voltage and the frequency are respectively varied over the whole range specified in the rated operated conditions, at current I and power factor PF i p
(ii) Method 2 When assuming that a Gaussian distribution may no longer be valid, instead a rectangular distribution should be assumed for the effects of influence factors.150 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] Thus, the combined maximum error can then be estimated from a combination of test results using the formula (3):
=2*
where: e is the maximum error obtained in the test for base maximum error, taking into account the base measurement uncertainty of the type test(2); e is the maximum error shift obtained in the test for voltage variation, taking into account voltage the measurement uncertainty of the type test;
e is the maximum error shift obtained in the test for frequency variation, taking into frequency account the measurement uncertainty of the type test; e is the maximum error shift obtained in the test for unbalance variation, taking into unbalance account the measurement uncertainty of the type test;
e is the maximum error shift obtained in the test for variation of harmonic content, taking harmonics into account the measurement uncertainty of the type test; e is the maximum error shift obtained in the test for temperature variation, taking into temperature account the measurement uncertainty of the type test.
Note (2): The measurement uncertainty must be included in each component e of the overall i error. Since one term is a known value and the other an uncertainty they cannot be treated as two uncorrelated statistical distributions, and must hence be added algebraically.
Note (3): Components contributing to the combined error may be selected and should at least
comprise: e , e , e and e . base frequency temperature voltage The effects of correlations between factors such as load profiles and ambient temperature variation on meter accuracy have not been included in the above calculations, but could be modeled in situations where appropriate.[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 151 ‘ANNEXURE- B’ Legislative matters
(Informative)
(1) This Notification provide an appropriate balance between flexibility and uniformity by the provision of options for a number of conditions, such as: a) Nominal voltage; b) Nominal frequency; c) Rated temperature;
d) Level of protection from water and humidity; e) Level of protection from impulse voltages; f) Handling of energy flow direction.
It should be noted that it may also include specific requirements relating to matters such as: g) Electrical interface; h) Mechanical interface and housing.
It should also be noted that, while the maximum current is most often specified by the characteristics of the installation, the value of the transitional current and/or the ratio between the maximum current and the transitional current are important for end customers with low power consumption, since these customers could experience large relative metering errors if the load current is lower than the transitional current for a large part of the time. The values of I tr and I may be chosen from Table 18.
max Table 18 Preferred current ranges Other values of I and tr Preferred values of I and I I tr max max Type of meter connection (Amperes) (Amperes)
Standard I values: 0.125, 0.25, Other I values: 0.75, tr tr Direct connection 0.5, 1, 2, 3. 1.5, 2.5, 4, 5
Standard I values: 10, 20, 40, Other I values:30, 50, max max 60, 80, 160 100, 120, 200, 320
Connection through Standard I values: 0.05, 0.1, tr current 0.25 Other I values: 0.125 tr
Standard I values: 1.2, 1.5, 2, max transformer(s) 2.4, 3, 4, 6, 7.5, 10, 20 Other I values 3.75, 5 max Note 1: The current range of transformer operated meters should be compatible with the current range of current transformers.152 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] Note 2: The Notification prescribe the maximum permissible I value, prescribe a minimum tr current range, or a minimum ratio between I and I. These can be prescribed as absolute max tr values or values based on the typical power demand for certain types of customers etc.
(i) Choice of accuracy class More accurate meters should be used when metering large flows of electricity in order to minimize the economic impact of unavoidable measurement errors. While class A meters may be acceptable for situations involving low energy consumption, higher class indices should be used when higher rates of energy consumption are involved.
The accuracy of the meter will be independent of the power grid characteristics for most meter connection modes; however, there may be a need to evaluate the influence of grid characteristics, especially for meters with higher class indices, in cases where there are underlying assumptions of grid symmetry and/or lack of leakage currents. It is possible that contributions to the overall meter error due to grid characteristics in such situations may be larger than contributions from the meter itself, especially at higher accuracy; it may therefore be appropriate to limit the use of connection modes of this type.
(ii) Matters not covered under this Notification This Notification is limited to describing the relevant metrological requirements of an electricity meter and therefore does not cover certain matters, such as:
a) EMC emissions; b) Electrical safety and personal safety; c) Security of communication protocols and further handling of measurement results. ‘ANNEXURE- C’: Description of selected validation methods 1 Analysis of documentation and specification and validation of the design (AD)
Application: Basic procedure, applicable during all software validation assessments.
Preconditions: The procedure is based on the manufacturer’s documentation of the measuring instrument.
Depending on the demands this documentation shall have adequate scope:
(1) Specification of the externally accessible functions of the instrument in a general form (Suitable for simple instruments with no interfaces except a display, all features verifiable by functional testing, low risk of fraud);
(2) Specification of software functions and interfaces (necessary for instruments with interfaces and for instrument functions that cannot be functionally tested and in case of increased risk of fraud). The description shall make evident and explain all software functions that may have an impact on metrological features;
(3) Concerning interfaces, the documentation shall include a complete list of[भाग II—खण्ड 3(i)] भारतकाराजपत्र:असाधारण 153 commands or signals that the software is able to interpret. The effect of each command shall be documented in detail. The way in which the instrument reacts on undocumented commands shall be described;
(4) Additional documentation of the software for complex measuring algorithms, cryptographic functions, or crucial timing constraints shall be provided, if necessary for understanding and evaluating the software functions;
(5) When it is not clear how to validate a function of a software program the onus to develop a test method should be placed on the manufacturer. In addition, the services of the programmer should be made available to the examiner for the purposes of answering questions.
A general precondition for examination is the completeness of the documentation and the clear identification of the EUT, i.e. of the software packages that contribute to the metrological functions.
Description: The examiner evaluates the functions and features of the measuring instrument using the description in text and graphical representations and decides whether these comply with the requirements. Metrological requirements as well as software- functional requirements (e.g. fraud protection, protection of adjustment parameters, disallowed functions, communication with other devices, update of software, fault detection, etc.) have to be considered and evaluated.
Result: The procedure gives a result for all characteristics of the measuring instrument,
provided that the appropriate documentation has been submitted by the manufacturer.
The result should be documented in a section related to software in a Software Evaluation Report.
Complementary procedures: Additional procedures should be applied, if examining the documentation cannot provide substantiated validation results. In most cases “Validating the metrological functions by functional testing” is a complementary procedure.
2 Validation by functional testing of the software functions (VFTSw)
Application: For validation of e.g. protection of parameters, indication of a software identification, software supported fault detection, configuration of the system (especially of the software environment), etc.
Preconditions: Operating manual, software documentation, functioning pattern, test equipment.
Description: Required features described in the operating manual, instrument documentation or software documentation is checked in practice. If software controlled and functioning correctly, they are to be regarded as validated without any further software analysis.
Result: Software controlled feature under consideration is OK or not OK.154 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)]
Complementary procedures: Some features or functions of a software controlled instrument cannot be practically validated as described. If the instrument has interfaces, it is in general not possible to detect unauthorized commands only by trying commands at random. Besides that, a sender is needed to generate these commands. For the normal validation level method E.1, including a declaration by the manufacturer, may cover this requirement. For the extended examination level, a software analysis such as C.3 or C.4 is necessary.
3 Metrological dataflow analysis (DFA)
Application: For analysis of the software design concerning the control of the data flow of measurement values through the data domains that are subject to legal control, including the examination of the software separation.
Description: It is the aim of this analysis to find all parts of the software that are involved in the calculation of the measurement values or that may have an impact on it.
4 Code inspection and walk through (CIWT)
Application: Any feature of the software may be validated with this method if enhanced examination intensity is considered necessary.
Description: The examiner walks through the source code assignment by assignment, evaluating the respective part of the code to determine whether the requirements are fulfilled and whether the program functions and features are in compliance with the documentation.
The examiner may also concentrate on algorithms or functions that he has identified as complex, error-prone, insufficiently documented, etc. and inspect the respective part of the source code by analyzing and checking.” [F. No. I-9/22/2014- W&M] ANUPAM MISHRA, Addl. Secy.
Note:- The principal rules were published in the Gazette of India, Extraordinary, Part II,
Section 3, Sub-section (i), vide notification number G.S.R.71(E), dated the 7th February, 2011 and was last amended, vide notification number G.S.R. 568 (E), dated the 03rd July, 2026.
Uploaded by Dte. of Printing at Government of India Press, Ring Road, Mayapuri, New Delhi-110064 and Published by the Controller of Publications, Delhi-110054.