Home India Petroleum and Natural Gas Regulatory Board In exercise of the powers conferred by section 61 of the Pet...
Date: 2016-11-24 Category: Extra Ordinary State: Union Government Country: India

In exercise of the powers conferred by section 61 of the Petroleum and Natural Gas Regulatory Board Act

Issued by Petroleum and Natural Gas Regulatory Board · Not Applicable

Research with AI Agent Chat with Document Generate Summary Translate Helpful Share Add to Project Create Task

Executive Summary & Key Takeaways

**Executive Summary:** This document contains amendments to the Petroleum and Natural Gas Regulatory Board (PNGRB) Technical Standards and Specifications, including Safety Standards for City or Local Natural Gas Distribution Networks Regulations, 2008. The amendments cover a range of technical specifications, material standards, and safety protocols within city gas distribution networks. These regulations were published in the Official Gazette on November 24, 2016, and come into force on the date of publication. **Key Points / Main Content:** * **Appendix I Amendments:** * Replaces "Steel reinforced rubber hose conforming to IS 9573 Type IV" with "Steel reinforced rubber hose conforming to IS 9573 Type II." * Modifies requirements for Emergency Response Plans, mandating a 24/7 manned Emergency Control Room with specific equipment. * **Schedule 1A Amendments:** * Restricts the use of copper pipes before the consumer meter to inside the kitchen only. * Specifies that PE fittings must conform to ISO 4437 Part 3 or EN 1555 Part 3. * Omits the heading and content regarding the reuse of Ductile Iron Pipes, thus disallowing it. * **Schedule 1C Amendments:** * Specifies that thermoplastic fittings must conform to ISO 4437 Part 3 or EN 1555 Part 3. * Removes the requirement that heating elements in fittings shall not be exposed. * **Schedule 1D Amendments:** * Removes language related to stream redundancy requirements in CGD network descriptions. * Replaces the formula for determining nominal wall thickness of plastic pipe with a statement about design pressure determination. * Mandates that PE fittings conform to ISO 4437 Part 3 or EN 1555 Part 3. * Removes the requirement for inbuilt fusion fittings beyond the external clamp system. * Replaces "Ductile iron, Cast Iron or Plastic Distribution system" with "PE Distribution System." * Removes the language regarding pressure control for domestic, small commercial, and small industrial consumers from high-pressure distribution systems. * Adds stipulations for reducing the depth of cover for gas service lines to 375 mm under specific conditions, including pressure limits, pipe diameter, and RCC slab use. * **Schedule 1E Amendments:** * Specifies that leakage survey methods described in ASME B31.8 can be adopted. * States that repair of Plastic Pipe or Tubing shall be in accordance with ASME B31.8. * **Annexure I Amendments:** * Replaces BS 5352 with BS EN ISO 15761 for steel gate, globe, and check valves. * Replaces BS 5351 with BS EN ISO 17292 for metal ball valves. * Replaces IS 1239 PART2 with IS 1239 Part2 for steel pipe fittings. * Replaces EN 10204 with EN 10204 for metallic products inspection documents. * Adds EN 12164 and EN 12165 for brass fittings. * **Annexure II Amendments:** * Replaces "OIML R6 OIML R31" with "OIML R 13712" for gas meters. * Replaces "BS 1359 BS 4161" with "BS 1359" for gas meters. * Removes reference to OIML R32 for rotary piston and turbine gas meters. * Replaces the standard for electrofusion machines with ISO 121762, EN55014, EN 6100063, EN 6100061, EN6100032, EN603351, and EN60335245. * **Annexure IV Amendments:** * Removes language specifying fittings for copper tubing. * Replaces BS EN 29453:1994 with BS EN ISO 9453 regarding filler metals. **Impact Analysis:** * **City Gas Distribution (CGD) Network Operators:** * *Impact:* CGD operators must adhere to the revised technical standards and specifications in their network design, operations, and maintenance. This includes changes to material specifications, safety protocols, and emergency response procedures. * *Action Required:* Review and update existing infrastructure, procedures, and training programs to comply with the new regulations. Implement the changes in material selection, installation practices, and emergency response protocols. * **Manufacturers and Suppliers:** * *Impact:* Manufacturers and suppliers of equipment and materials used in CGD networks must ensure their products meet the updated standards and specifications outlined in the amendments. * *Action Required:* Modify product designs and manufacturing processes to comply with the revised standards. Update product documentation and certifications to reflect compliance with the new regulations. * **Petroleum and Natural Gas Regulatory Board (PNGRB):** * *Impact:* PNGRB is responsible for enforcing the updated regulations and ensuring compliance among CGD network operators and other stakeholders. * *Action Required:* Update regulatory frameworks, conduct inspections, and provide guidance to ensure effective implementation of the amended regulations. * **Consumers:** * *Impact:* Consumers benefit from enhanced safety measures and improved reliability of gas distribution networks resulting from the updated technical standards. * *Action Required:* Be aware of potential changes in service line installation practices, particularly those related to reduced depth of cover, and cooperate with CGD operators during any necessary upgrades or maintenance activities.

Key Entities Referenced

IS 14885: Indian Standard specification for Polyethylene (PE) pipes for the conveyance of gaseous fuels – Metric series – Specifications ISO 4437: International Organization for Standardization specification for Buried polyethylene (PE) pipes for the supply of gaseous fuels — Metric series — Specifications IS 9573 Type II: Indian Standard specification for Steel reinforced rubber hose, Type II Petroleum and Natural Gas Regulatory Board: A regulatory body responsible for the petroleum and natural gas sector in India. Petroleum and Natural Gas Regulatory Board Act, 2006: The act establishing the Petroleum and Natural Gas Regulatory Board and defining its powers. Petroleum and Natural Gas Regulatory Board Technical Standards and Specifications including Safety Standards for City or Local Natural Gas Distribution Networks Regulations, 2008: Regulations set forth by the Petroleum and Natural Gas Regulatory Board regarding technical and safety standards for city or local natural gas distribution networks. New Delhi: The location where the notification was issued. IS 9573 Type IV: Indian Standard specification for Steel reinforced rubber hose, Type IV
Official Source Record View Original Source →
See Full Document Text
jftLVªh laö Mhö ,yö&33004@99 REGD. NO. D. L.-33004/99 vlk/kj.k EXTRAORDINARY Hkkx III—[k.M 4 PART III—Section 4 izkf/dkj ls izdkf'kr PUBLISHED BY AUTHORITY la- 426] ubZ fnYyh] c`gLifrokj] uoEcj 24] 2016@vxzgk;.k 3] 1938 No. 426] NEW DELHI, THURSDAY, NOVEMBER 24, 2016/AGRAHAYANA 3, 1938 प(cid:7069)े ोिलयम एव ं(cid:7079)ाकृितक गसै िविनयामक बोड (cid:6981) अिधसचू ना नई (cid:7408)द(cid:7016)ली, 24 नव(cid:7013)बर, 2016 फा.स.ं एम(आई)/टी4एस/सीजीडी/1/2010.—पे(cid:7069)ोिलयम और (cid:7079)ाकृितक गैस िविनयामक बोड(cid:6981) अिधिनयम, 2006 (2006 का 19) क(cid:7409) धारा 61 (cid:7367)ारा (cid:7079)द(cid:7275) शि(cid:7334)य(cid:7298) का (cid:7079)योग करते (cid:7263)ए पे(cid:7069)ोिलयम और (cid:7079)ाकृितक गैस िविनयामक बोड(cid:6981) एत(cid:7375)ारा पे(cid:7069)ोिलयम और (cid:7079)ाकृितक गैस िविनयामक बोड(cid:6981) (नगर या (cid:7021)थानीय (cid:7079)ाकृितक गैस िवतरण नेटवक(cid:6981) के िलए सुर(cid:6979)ा मानक(cid:7298) सिहत तकनीक(cid:7409) मानक और िविशि(cid:7397)यां), 2008 म(cid:7286) संशोधन करने के िलए िन(cid:7388)िलिखत िविनयम बनाता ह,ै नामत:- 1. लघ ुशीष(cid:6981)क और (cid:7079)ारंभ: (1) इन िविनयम(cid:7298) को पे(cid:7069)ोिलयम और (cid:7079)ाकृितक गैस िविनयामक बोड(cid:6981) (नगर या (cid:7021)थानीय (cid:7079)ाकृितक गैस िवतरण नेटवक(cid:6981) के िलए सुर(cid:6979)ा मानक(cid:7298) सिहत तकनीक(cid:7409) मानक और िविशि(cid:7397)यां) संशोधन िविनयम, 2016 कहा जाएगा। (2) ये िविनयम सरकारी राजप(cid:7074) म(cid:7286) उनके (cid:7079)काशन क(cid:7409) तारीख से (cid:7079)वृत ह(cid:7298)गे। 2. पे(cid:7069)ोिलयम और (cid:7079)ाकृितक गैस िविनयामक बोड(cid:6981) (नगर या (cid:7021)थानीय (cid:7079)ाकृितक गैस िवतरण नेटवक(cid:6981) के िलए सुर(cid:6979)ा मानक(cid:7298) सिहत तकनीक(cid:7409) मानक और िविशि(cid:7397)यां) िविनयम 2008 म(cid:7286),- (i)(cid:32) प(cid:7407)रिश(cid:7397) I, (cid:7059)मांक सं(cid:6990)या 6 म(cid:7286), शीष(cid:6981)क "मह(cid:7004)वपूण(cid:6981) अवसंरचना /काय(cid:6981)कलाप / (cid:7079)(cid:7408)(cid:7059)याएं," के अंतग(cid:6981)त "आईएस 9573 टाइप IV के अनु(cid:7271)प (cid:7021)टील (cid:7411)रफोस(cid:6981)ड रबड़ होज” के िलए, िन(cid:7388)िलिखत, (cid:7079)ित(cid:7021)थािपत (cid:7408)कया जाएगा, नामत:- "आईएस 9573 टाइप II के अनु(cid:7271)प (cid:7021)टील (cid:7411)रफोस(cid:6981)ड रबड़ होज।"; (ii)(cid:32) प(cid:7407)रिश(cid:7397) I (cid:7059)मांक सं(cid:6990)या 9 म(cid:7286), शीष(cid:6981)क "मह(cid:7004)वपूण(cid:6981) अवसंरचना / काय(cid:6981)कलाप / (cid:7079)(cid:7408)(cid:7059)याएं," के अंतग(cid:6981)त आरि(cid:7013)भक श(cid:7011)द “आपातकाल (cid:7079)ित(cid:7408)(cid:7059)या योजना, आपदा (cid:7079)बंधन योजना और िलिखत आपातकाल (cid:7079)(cid:7408)(cid:7059)याएं ...” और “…. साम(cid:7061)ी सुर(cid:6979)ा आंकड़ा शीट आ(cid:7408)द, उपल(cid:7011)ध कराए गए ह(cid:7298)।”, से समा(cid:7385) श(cid:7011)द(cid:7298) के िलए, िन(cid:7388)िलिखत से (cid:7079)ित(cid:7021)थािपत (cid:7408)कया जाएगा, नामत :— “आपातकाल (cid:7079)ित(cid:7408)(cid:7059)या योजना, आपदा (cid:7079)बंधन योजना तथा िलिखत आपातकाल (cid:7079)(cid:7408)(cid:7059)याएं। इनके अलावा, आपातकाल िनयं(cid:7074)ण क(cid:6979), िजसम(cid:7286) चौबीस घंट े तैनाती व (cid:7079)भावी संचार (cid:7079)णाली ह(cid:7298) तथा आपातकाल वाहन िजसम (cid:7286) संचार सुिवधाएं लगाई गई ह(cid:7298), 5439 GI/2016 (1)2 THE GAZETTE OF INDIA : EXTRAORDINARY [PART III—SEC. 4] (cid:7079)ाथिमक िच(cid:7408)क(cid:7004)सा उपकरण, अि(cid:7336)शामक यं(cid:7074), गैस संसूचक, मर(cid:7013)मत (cid:7408)कट एवं औजार, मानिच(cid:7074), योजना, साम(cid:7061)ी सुर(cid:6979)ा, आंकड़ा शीट आ(cid:7408)द उपल(cid:7011)ध कराए गए ह(cid:7298)।”; (iii)(cid:32) अनुसूची-1क म(cid:7286), “मीटर सेट तथा सतह से ऊपर स(cid:7414)वस लाइन(cid:7298) के िलए पाइप(cid:7286) और (cid:7351)ूब(cid:7286)” शीष(cid:6981)क के अंतग(cid:6981)त आरि(cid:7013)भक श(cid:7011)द ”ताबं े क(cid:7409) (cid:7351)ूब का (cid:7079)योग उपभो(cid:7334)ा के .....’’ और “……यह तृतीय प(cid:6979) के िलए सुलभ नही ह।ै” से समा(cid:7385) श(cid:7011)द(cid:7298) म(cid:7286) िन(cid:7388)िलिखत को जोड़ा जाएगा, नामत:- “ता(cid:7013)बे क(cid:7409) पाइप / (cid:7351)ूब उपभो(cid:7334)ा के मीटर से पूव(cid:6981) केवल रसोई के अंदर (cid:7079)योग होनी चािहए।“; (iv)(cid:32) अनुसूची1-क म(cid:7286), “(cid:7009) लाि(cid:7021)टक पाइप और घटक” शीष(cid:6981)क के अंतग(cid:6981)त आरि(cid:7013)भक श(cid:7011)द “ आईएस 14885 या आईएसओ 4437 ..... ” और “… आईएसओ 8085 भाग 3 के अनु(cid:7271)प पीई (cid:7408)फ(cid:7411)टग (cid:7021)वीकाय(cid:6981) होगा।” से समा(cid:7385) श(cid:7011)द(cid:7298) को िन(cid:7388)िलिखत से (cid:7079)ित(cid:7021)थािपत (cid:7408)कया जाएगा, नामत:- “आईएस 14885 या आईएसओ 4437 के अनु(cid:7271)प पोिलिथलेन(पीई) पाइप(cid:7298) और आईएसओ 4437 भाग 3 या ईएन 1555 भाग 3 के अनु(cid:7271)प पीई (cid:7408)फ(cid:7411)टग (cid:7021)वीकाय(cid:6981) होगा। ” ; (v)(cid:32) अनुसूची-1क म(cid:7286), “पाइप के पुन: (cid:7079)योग क(cid:7409) ि(cid:7021)थितयां” शीष(cid:6981)क के अंतग(cid:6981)त श(cid:7011)द “लचीली लोह ेक(cid:7409) पाइप के (cid:7079)योग क(cid:7409) अनुमित नही होगी।” हटा (cid:7408)दया जाएगा; (vi)(cid:32) अनुसूची1-ग म(cid:7286), “वा(cid:7016)व और (cid:7010)ल(cid:7289)िजस के अलावा (cid:7408)फ(cid:7411)टग” शीष(cid:6981)क के अंतग(cid:6981)त “आईएसओ 8085 भाग 3 के अनु(cid:7271)प थम(cid:7299)(cid:7009)लाि(cid:7021)टक (cid:7408)फ(cid:7411)ट(cid:6991)स (cid:7021)वीकाय(cid:6981) होगी और ये िन(cid:7388)िलिखत आव(cid:7019)य(cid:7334)ा(cid:7312) को पूरा कर(cid:7286)गी:” श(cid:7011)द(cid:7298) को िन(cid:7388)िलिखत से (cid:7079)ित(cid:7021)थािपत (cid:7408)कया जाएगा, नामत:- “आईएसओ 4437 भाग 3 या ईएन 1555 भाग 3 के अनु(cid:7271)प थम(cid:7299)(cid:7009)लाि(cid:7021)टक (cid:7408)फ(cid:7411)ट(cid:6991)स (cid:7021)वीकाय(cid:6981) ह(cid:7298)गी और ये िन(cid:7388)िलिखत आव(cid:7019)य(cid:7334)ा(cid:7312) को पूरा कर(cid:7286)ग(cid:7277);”: (vii)(cid:32) अनुसूची1-ग म(cid:7286), “वा(cid:7016)व और (cid:7010)ल(cid:7286)िजस के अलावा (cid:7408)फ(cid:7411)टग”, शीष(cid:6981)क के अंतग(cid:6981)त उप पैरा(ख), श(cid:7011)द “गम(cid:6981) होने वाले घटक(cid:7298) को खुला नह(cid:7277) छोड़ा जाएगा और सभी कॉयल (cid:7408)फ(cid:7411)टग के ढांचे म(cid:7286) ही लगाए जाएंग(cid:7286)।” हटा (cid:7408)दया जाएगा; (viii)(cid:32) अनुसूची 1घ म(cid:7286), “सीजीडी नेटवक(cid:6981) (cid:7390)ा(cid:6990)या”, (cid:7059)मांक iv) एवं v) म(cid:7286) “(चरण म(cid:7286) अित(cid:7407)र(cid:6989)(cid:7275)ता 2+1 से कम नह(cid:7277) होगी)।” श(cid:7011)द(cid:7298) को हटा (cid:7408)दया जाएगा; (ix)(cid:32) अनुसूची 1घ म(cid:7286), “(cid:7009)लाि(cid:7021)टक पाइप और (cid:7351)ूब िडजाइन फामू(cid:6981)ला”, शीष(cid:6981)क के अंतग(cid:6981)त आरि(cid:7013)भक श(cid:7011)द “(cid:7009)लाि(cid:7021)टक पाइप क(cid:7409) दीवार सामा(cid:7008)य मोटाई क(cid:7409) गणना” ...........” और “...... के अनुसार क(cid:7409) जाएगी”, पर समा(cid:7385) श(cid:7011)द(cid:7298) को िन(cid:7388)िलिखत से (cid:7079)ित(cid:7021)थािपत (cid:7408)कया जाएगा, नामत :— “(cid:7009)लाि(cid:7021)टक गैस पाइ(cid:7410)पग (cid:7079)णाली का िडजाइन दबाव या (cid:7408)दवार क(cid:7409) नाममा(cid:7074) मोटाई (cid:7408)कसी (cid:7408)दए गए िडजाइन दबाव हते ु िन(cid:7388)िलिखत सू(cid:7074) (cid:7367)ारा िनधा(cid:6981)(cid:7407)रत (cid:7408)कया जाएगा:”; (x)(cid:32) अनुसूची 1घ म(cid:7286), “(cid:7009)लाि(cid:7021)टक (cid:7408)फ(cid:7411)टग का िडजाइन दबाव” शीष(cid:6981)क के अंतग(cid:6981)त “सभी पीई (cid:7408)फ(cid:7411)टग आईएसओ 8085 भाग 3 के अनु(cid:7271)प होनी चािहए” श(cid:7011)द(cid:7298) को िन(cid:7388)िलिखत से (cid:7079)ित(cid:7021)थािपत (cid:7408)कया जाएगा, नामत :— ”सभी पीई (cid:7408)फ(cid:7411)टग आईएसओ 4437 भाग 3 या ईएन 1555 भाग 3 के अनु(cid:7271)प होनी चािहए।”; (xi)(cid:32) अनुसूची 1घ, “(cid:7009)लाि(cid:7021)टक पाइप और (cid:7351)ूब के जोड़ तथा कने(cid:6989)शन” शीष(cid:6981)क म(cid:7286) उप-शीष(cid:6981)क, “सामा(cid:7008)य (cid:7079)ावधान” म(cid:7286) “(cid:7010)यूजन (cid:7408)फ(cid:7411)ट(cid:6991)स म(cid:7286) 60 मी.मी. और उससे अिधक बाहरी (cid:6989)लै(cid:7013)प िस(cid:7021)टम म(cid:7286) अंत(cid:7414)निहत (cid:7079)ावधान होना चिहए।” श(cid:7011)द(cid:7298) को हटा (cid:7408)दया जाएगा; (xii)(cid:32) अनुसूची 1घ म(cid:7286), उप शीष(cid:6981)क “ उ(cid:7340) दबाव (cid:7021)टील, लचीला लोहा, ढलवां लोहा या (cid:7009)लाि(cid:7021)टक िवतरण (cid:7079)णाली म(cid:7286) गैस दबाव का िनयं(cid:7074)ण और सीमा” श(cid:7011)द(cid:7298) को िन(cid:7388)िलिखत से (cid:7079)ित(cid:7021)थािपत (cid:7408)कया जाएगा, नामत:- “उ(cid:7340) दबाव (cid:7021)टील या पीई िवतरण (cid:7079)णाली म(cid:7286) गैस दबाव का िनयं(cid:7074)ण और सीमा।”; (xiii)(cid:32) अनुसूची 1घ म(cid:7286), उप शीष(cid:6981)क “अ(cid:7016)प दबाव िवतरण (cid:7079)णाली म(cid:7286) गैस दबाव का िनयं(cid:7074)ण और सीमा” के अंतग(cid:6981)त “उ(cid:7340) दबाव िवतरण (cid:7079)णाली से घरेलू, लघु वािणि(cid:6996)यक और लघु उ(cid:7378)ोग उपभो(cid:7334)ा(cid:7312) को गैस िनयंि(cid:7074)त और सीिमत दबाव पर दी जाती ह।ै ” श(cid:7011)द(cid:7298) को हटा (cid:7408)दया जाएगा।;¹Hkkx IIIµ[k.M 4º Hkkjr dk jkti=k % vlk/kj.k 3 (xiv)(cid:32) अनुसूची 1घ म(cid:7286), शीष(cid:6981)क, “गैस सेवा लाइन(cid:7286)” के उप-शीष(cid:6981)क “सेवा लाइन(cid:7298) क(cid:7409) (cid:7021)थापना” के पैरा(cid:7061)ाफ के अंत म(cid:7286) आरि(cid:7013)भक श(cid:7011)द “सभी (cid:7009)लाि(cid:7021)टक पाइप और (cid:7408)फ(cid:7411)टग.......” और “....”बंद जगह म(cid:7286) रोशनदान उपल(cid:7011)ध कराए जाने चािहए।“ श(cid:7011)द क(cid:7409) समाि(cid:7385) पर िन(cid:7388)िलिखत को जोड़ा जाएगा, नामत: “कवर क(cid:7409) गहराई 375 मी.मी. तक कम क(cid:7409) जा सकती ह ैबशत(cid:7287) (cid:7408)क यह िन(cid:7388)िलिखत आव(cid:7019)यकता(cid:7312) क(cid:7409) पू(cid:7414)त करती ह(cid:7298): क.(cid:32) लाइन दबाव 110 िमलीबार से अिधक नह(cid:7277) होगा। ख.(cid:32) पाइप का (cid:7390)ास 63 िममी से अिधक नह(cid:7277) होगा। ग.(cid:32) ऊपर और नीचे (cid:7079)बिलत सीम(cid:7286)ट कं(cid:7059)(cid:7409)ट (आरसीसी) (cid:7021)लैब के साथ पाइप एक (cid:7069)(cid:7289)च म(cid:7286) रखा जाएगा। बेसम(cid:7286)ट क(cid:7409) आरसीसी (cid:7021)लैब क(cid:7409) छत को तली के (cid:7272)प म(cid:7286) माना जाएगा। घ.(cid:32) (cid:7079)(cid:7004)येक लाइन पाइप के तीन(cid:7298) ओर 100 मी.मी. रेत भरी जाएगी। ङ.(cid:32) टॉप पर आरसीसी क(cid:7409) मोटाई (cid:7008)यूनतम 150 िम.मी. होगी। च.(cid:32) टॉप साइड को वा(cid:7418)नग मैट से आ(cid:6994)छा(cid:7408)दत (cid:7408)कया जाएगा। छ.(cid:32) साइट क(cid:7409) मा(cid:7074)ा(cid:7004)मक जोिखम मू(cid:7016)यांकन ((cid:6989)यूआरए)(cid:7408)कया जाएगा। कवर क(cid:7409) गहराई को 375 मी..मी. तक कम करने के िलए (cid:7079)बंधन से िविश(cid:7397) अनुमोदन (cid:7079)ा(cid:7385) (cid:7408)कया जाएगा। ज.(cid:32) साइट िनजी संपि(cid:7275) होगी अथा(cid:6981)त ब(cid:7263)मंिजला इमारत(cid:7286) / अपाट(cid:6981)म(cid:7286)ट जहां भारी वाहन(cid:7298) क(cid:7409) आवाजाही न हो।”; (xv)(cid:32) अनुसूची1 ड.ं म(cid:7286), उप-शीष(cid:6981)क “(cid:7407)रसाव संबंधी सव(cid:7287)(cid:6979)ण” के अंतग(cid:6981)त “कोई भी या एएसएमई बी 31.8, प(cid:7407)रिश(cid:7397) एम म(cid:7286) व(cid:7414)णत संयु(cid:7334) प(cid:7007)दित को िविश(cid:7397) (cid:6979)े(cid:7074)(cid:7298) म(cid:7286) उनक(cid:7409) (cid:7079)भावका(cid:7407)रता के आधार पर अपनाया जा सकता ह।ै “ श(cid:7011)द(cid:7298) को िन(cid:7388)िलिखत से (cid:7079)ित(cid:7021)थािपत (cid:7408)कया जाएगा नामत:- “कोई भी या एएसएमई बी 31.8 म(cid:7286) व(cid:7414)णत संयु(cid:7334) प(cid:7007)दित को िविश(cid:7397) (cid:6979)े(cid:7074)(cid:7298) म(cid:7286) उनक(cid:7409) (cid:7079)भावका(cid:7407)रता के आधार पर अपनाया जा सकता ह।ै”; (xvi)(cid:32) अनुसूची 1डं. म(cid:7286), “(cid:7009)लाि(cid:7021)टक पाइप या (cid:7351)ूब क(cid:7409) मर(cid:7013)मत” उप शीष(cid:6981)क के अंतग(cid:6981)त “मर(cid:7013)मत प(cid:7007)दित म(cid:7286) केवल पूरे गोल टुकड े को लगाने क(cid:7409) ही अनुमित दी जाती ह ै जो एएसएमई बी 31.8 के अनुसार होनी चािहए।” श(cid:7011)द(cid:7298) को िन(cid:7388)िलिखत से (cid:7079)ित(cid:7021)थािपत (cid:7408)कया जाएगा, नामत:- “(cid:7009)लाि(cid:7021)टक पाइप या (cid:7351)ू(cid:7410)बग क(cid:7409) मर(cid:7013)मत एएसएमई बी 31.8 के अनुसार होनी चािहए।“; (xvii)(cid:32) अनुबंध 1 म(cid:7286), “सी.जी.डी. ढ़ांचे म(cid:7286) (cid:7079)यु(cid:7334) होने वाली पाइप साम(cid:7061)ी क(cid:7409) िविशि(cid:7397)य(cid:7298) क(cid:7409) सूची” शीष(cid:6981)क के अंतग(cid:6981)त उप-शीष(cid:6981)क, “वा(cid:7016)व” के िलए आरि(cid:7013)भक श(cid:7011)द “बीएस 5352.....“ और “...छोटे वा(cid:7016)ब क(cid:7409) िविशि(cid:7397)यां।“ पर समा(cid:7385) श(cid:7011)द(cid:7298) को िन(cid:7388)िलिखत से (cid:7079)ित(cid:7021)थािपत (cid:7408)कया जाएगा, नामत :— “बीएस ईएन आईएसओ 15761 : पे(cid:7069)ोिलयम और (cid:7079)ाकृितक गैस उ(cid:7378)ोग हते ु (cid:7021)टील गेट, (cid:6991)लोब एवं चेक वा(cid:7016)व, साईज डीएन 100 और छोट ेके िलए।”; (xviii)(cid:32) अनुबंध 1 म(cid:7286), “सी.जी.डी. ढ़ाच(cid:7286) म(cid:7286) (cid:7079)यु(cid:7334) होने वाली पाइप साम(cid:7061)ी क(cid:7409) िविशि(cid:7397)य(cid:7298) क(cid:7409) सूची” शीष(cid:6981)क के अंतग(cid:6981)त उप-शीष(cid:6981)क, “वा(cid:7016)व” के िलए आरि(cid:7013)भक श(cid:7011)द “बीएस 5351 ........” और “…. छोटे (cid:7010)लो(cid:7411)टग बॉल वा(cid:7016)व” पर समा(cid:7385) श(cid:7011)द(cid:7298) के िलए िन(cid:7388)िलिखत से (cid:7079)ित(cid:7021)थािपत जाएगा, नामत:- “बीएस ईएन आईएसओ 17292 : पे(cid:7069)ोिलयम, पे(cid:7069)ोकेिमकल और संब(cid:7007)द उ(cid:7378)ोग(cid:7298) के िलए मेटल बॉल वा(cid:7016)(cid:7018)स।“; (xix)(cid:32) अनुबंध 1 म(cid:7286), “सी.जी.डी. ढ़ांचे म(cid:7286) (cid:7079)यु(cid:7334) होने वाली पाइप साम(cid:7061)ी क(cid:7409) िविशि(cid:7397)य(cid:7298) क(cid:7409) सूची” शीष(cid:6981)क के अंतग(cid:6981)त उप-शीष(cid:6981)क ”(cid:7408)फ(cid:7411)ट(cid:6991)स” म(cid:7286) “आईएस 1239 (भाग 2) (cid:7021)टील (cid:7351)ूब, नलीदार और अ(cid:7008)य मजबूत (cid:7021)टील (cid:7332)(cid:7409) (cid:7408)फ(cid:7411)टग िविशि(cid:7397)यां भाग-1 माइ(cid:7016)ड (cid:7021)टील नलीपार और मजबूत (cid:7021)टील क(cid:7409) बनी अ(cid:7008)य पाइप (cid:7408)फ(cid:7411)टग।” श(cid:7011)द(cid:7298) को िन(cid:7388)िलिखत से (cid:7079)ित(cid:7021)थािपत जाएगा, नामत:- “आईएस 1239 (भाग-2):(cid:7021)टील (cid:7351)ूब, नलीदार और अ(cid:7008)य (cid:7021)टील (cid:7408)फ(cid:7411)ट(cid:6991)स- िविशि(cid:7397)यां-भाग 2: (cid:7021)टील पाइप (cid:7408)फ(cid:7411)ट(cid:6991)स।”;4 THE GAZETTE OF INDIA : EXTRAORDINARY [PART III—SEC. 4] (xx)(cid:32) अनुबंध 1 म(cid:7286), “सी.जी.डी. ढ़ांचे म(cid:7286) (cid:7079)यु(cid:7334) होने वाली पाइप साम(cid:7061)ी क(cid:7409) िविशि(cid:7397)य(cid:7298) क(cid:7409) सूची” शीष(cid:6981)क के अंतग(cid:6981)त उप-शीष(cid:6981)क, ”(cid:7009)लाि(cid:7021)टक वा(cid:7016)व” म(cid:7286) “ईएन 10204-अित(cid:7407)र(cid:7334) (cid:7079)वाह िनयं(cid:7074)ण वा(cid:7016)व” श(cid:7011)द(cid:7298) को िन(cid:7388)िलिखत से (cid:7079)ित(cid:7021)थािपत (cid:7408)कया जाएगा, नामत :— “ईएन 10204: धातु सद(cid:7019)ृ य उ(cid:7004)पाद(cid:7298) – िनरी(cid:6979)ण द(cid:7021)तावेज(cid:7298) के (cid:7079)कार”; (xxi)(cid:32) अनुबंध 1 म(cid:7286), “सी.जी.डी. ढ़ाच(cid:7286) म(cid:7286) (cid:7079)यु(cid:7334) होने वाली पाइप साम(cid:7061)ी क(cid:7409) िविशि(cid:7397)य(cid:7298) क(cid:7409) सूची” शीष(cid:6981)क के अंतग(cid:6981)त उप-शीष(cid:6981)क, “पीतल क(cid:7409) बनी (cid:7408)फ(cid:7411)टग,” म(cid:7286) “आईएस 319 ि(cid:7079)क(cid:7411)टग लैडडे पीतल क(cid:7409) छड़(cid:7286), स(cid:7407)रए और उनके टुकड़ े – िविश(cid:7397)ता:- ” श(cid:7011)द(cid:7298) के प(cid:7391)ात िन(cid:7388)िलिखत जोड़ा जाएगा, नामत :- “ईएन 12164: तांबा और तांबा िमि(cid:7088)त धातु। मु(cid:7334) मशी(cid:7410)नग (cid:7079)योजनाथ(cid:6981) (cid:6995)ड़ । ईएन 12165: तांबा और तांबा िमि(cid:7088)त धातु। गढ़ा और अनगढ़ा फो(cid:7418)जग (cid:7021)टॉक।“; (xxii)(cid:32) अनुबंध 2 म(cid:7286), “सी.जी.डी. ढ़ाच(cid:7298) म(cid:7286) इ(cid:7021)तेमाल होने वाले उपकरण(cid:7298) क(cid:7409) िविशि(cid:7397)य(cid:7298) क(cid:7409) सूची” शीष(cid:6981)क के अंतग(cid:6981)त उपशीष(cid:6981)क-,”िमट(cid:7411)रग (मापन) उपकरण” म(cid:7286) “ओआईएमएल आर6 / ओआईएमएल आर31 डाई(cid:7080)ाम गैस मीटर” श(cid:7011)द(cid:7298) को िन(cid:7388)िलिखत से (cid:7079)ित(cid:7021)थािपत (cid:7408)कया जाएगा, नामत:- “ओआईएमएल आर 137-1 एवं 2: गैस मीटस(cid:6981)।”; (xxiii)(cid:32) अनुबंध 2 म(cid:7286), “सी.जी.डी. ढ़ाच(cid:7298) म(cid:7286) इ(cid:7021)तेमाल होने वाले उपकरण(cid:7298) क(cid:7409) िविशि(cid:7397)य(cid:7298) क(cid:7409) सूची” शीष(cid:6981)क के अंतग(cid:6981)त उप-शीष(cid:6981)क,”िमट(cid:7411)रग (मापन) उपकरण” म(cid:7286) “बीएस 1359 / बीएस 4161 डाई(cid:7080)ाम गैस मीटर” श(cid:7011)द(cid:7298) को िन(cid:7388)िलिखत से (cid:7079)ित(cid:7021)थािपत (cid:7408)कया जाएगा, नामत:- “बीएस 1359: गैस मीटस(cid:6981) - डाई(cid:7080)ाम गैस मीटस(cid:6981)।“; (xxiv)(cid:32) अनुबंध 2 म,(cid:7286) “सी.जी.डी. ढ़ांचो म(cid:7286) इ(cid:7021)तेमाल होने वाले उपकरण(cid:7298) क(cid:7409) िविशि(cid:7397)य(cid:7298) क(cid:7409) सूची” शीष(cid:6981)क के अंतग(cid:6981)त उपशीष(cid:6981)क-, “िमट(cid:7411)रग (मापन) उपकरण” म(cid:7286) “ओआईएमएल आर32- रोटरी िप(cid:7021)टन गैस मीटर तथा टबा(cid:6981)ईन गैस मीटर” श(cid:7011)द(cid:7298) को हटा (cid:7408)दया जाएगा; (xxv)(cid:32) अनुबंध 2 म(cid:7286), “सी.जी.डी. ढ़ाच(cid:7298) म(cid:7286) इ(cid:7021)तेमाल होने वाले उपकरण(cid:7298) क(cid:7409) िविशि(cid:7397)य(cid:7298) क(cid:7409) सूची” शीष(cid:6981)क के अंतग(cid:6981)त उपशीष(cid:6981)क- “पी.ई.पाइप और (cid:7408)फ(cid:7411)टग को जोड़ने हेतु इले(cid:6989)(cid:7069)ो (cid:7010)यूजन मशीन” श(cid:7011)द(cid:7298) को िन(cid:7388)िलिखत से (cid:7079)ित(cid:7021)थािपत (cid:7408)कया जाएगा, नामत:- “आईएसओ-12176-2: (cid:7009)लाि(cid:7021)टक पाइप और (cid:7408)फ(cid:7411)टग – (cid:7010)यूजन (cid:6996)य(cid:7298)(cid:7411)टग पॉिलिथलेन (cid:7079)णाली के िलए उपकरण-भाग 2: इले(cid:6989)(cid:7069)ो(cid:7010)यूजन। इएमसी मानक “ईएन- 55014 : िव(cid:7378)ुत चािलत मोटर और तथा घरेलू थम(cid:6981)ल उपकरण और सद(cid:7019)ृ य (cid:7079)योजन(cid:7298) हते ु, वै(cid:7378)ुत औजार व सम(cid:7271)प वै(cid:7378)ुत उपकरण तथा रेिडयो िव(cid:6979)ोम िवशेषता(cid:7312) क(cid:7409) माप के तरीके व सीमाए।ं ईएन 61000-6-3: िव(cid:7378)ुतचु(cid:7013)बक(cid:7409)य संगतता (ईएमसी) : जेने(cid:7407)रक मानक-आवासीय, वािणि(cid:6996)यक और ह(cid:7016)के-औ(cid:7378)ोिगक वातावरण के िलए उ(cid:7004)सज(cid:6981)न मानक। ईएन 61000-6-1: िव(cid:7378)ुतचु(cid:7013)बक(cid:7409)य संगतता (ईएमसी):जेने(cid:7407)रक मानक-आवासीय, वािणि(cid:6996)यक और ह(cid:7016)के-औ(cid:7378)ोिगक वातावरण (cid:6979)मता के िलए उ(cid:7008)मुि(cid:7334) । ईएन-61000-3–2: िव(cid:7378)ुतचु(cid:7013)बक(cid:7409)य संगतता (ईएमसी): सीमाएं- हाम(cid:7299)िनक तरंग उ(cid:7004)सज(cid:6981)न (उपकरण इनपुट तरंग < 16ए (cid:7079)ित चरण) क(cid:7409) सीमाएं। ईएन-60335-1: घरेलू और सद(cid:7019)ृ य वै(cid:7378)ुत उपकरण: सुर(cid:6979)ा- सामा(cid:7008)य आव(cid:7019)यकताएं। ईएन-60335-2-45: घरेलू और सद(cid:7019)ृ य वै(cid:7378)ुत उपकरण: सुर(cid:6979)ा- पोट(cid:7287)बल ही(cid:7411)टग औजार और सद(cid:7019)ृ य वै(cid:7378)ुत उपकरण के िलए िवशेष आव(cid:7019)यकताएं ”; (xxvi)(cid:32) अनुल(cid:7336)क- IV म(cid:7286), “(cid:7061)ाहक के उपकरण(cid:7298) तक स(cid:7414)वस लाइन(cid:7298) म(cid:7286) (cid:7079)योग (cid:7408)कए गए जीआई पाइप(cid:7298) और ताबं े क(cid:7409) (cid:7351)ूब(cid:7298) के िलए (cid:7008)यूनतम आव(cid:7019)यकताएं” शीष(cid:6981)क के अंतग(cid:6981)त उप-शीष(cid:6981)क “तांबे क(cid:7409) (cid:7351)ू(cid:7410)बग” म(cid:7286) श(cid:7011)द(cid:7298) “ताबं े क(cid:7409) (cid:7351)ूब को जो(cid:7037)ने के िलए उपयोग क(cid:7409) जाने वाली (cid:7408)फ(cid:7411)टग और बीएसईएन 1254 भाग 1 और 2 के अनुसार होगी।”, को हटा (cid:7408)दया जाएगा।¹Hkkx IIIµ[k.M 4º Hkkjr dk jkti=k % vlk/kj.k 5 (xxvii)(cid:32) अनुल(cid:7336)क- IV म(cid:7286), “(cid:7061)ाहक के उपकरण(cid:7298) तक स(cid:7414)वस लाइन(cid:7298) म(cid:7286) (cid:7079)योग (cid:7408)कए गए जीआई पाइप(cid:7298) और तांबे क(cid:7409) (cid:7351)ूब(cid:7298) के िलए (cid:7008)यूनतम आव(cid:7019)यकताएं” शीष(cid:6981)क के अंतग(cid:6981)त उप-शीष(cid:6981)क “तांबे क(cid:7409) (cid:7351)ू(cid:7410)बग” म(cid:7286) “भराई धातु बीएसईएन 29453:1994 के अनुसार सॉ(cid:7010)ट सो(cid:7016)ड(cid:7411)रग धातु-रसायन संयोजन और उसके (cid:7271)प ह(cid:7298)ग़े।” श(cid:7011)द(cid:7298) को िन(cid:7388)िलिखत से (cid:7079)ित(cid:7021)थािपत (cid:7408)कया जाएगा, नामत :- “भराई धातु बीएस ईएन आईएसओ 9453: िव(cid:7378)ुत चु(cid:7013)बक(cid:7409)य संगतता (ईएमसी): जेने(cid:7407)रक मानक -आवासीय, वािणि(cid:6996)यक और ह(cid:7016)के-औ(cid:7378)ोिगक वातावरण के िलए उ(cid:7008)मुि(cid:7334) के अनुसार होगी।"। व(cid:7008)दना शमा(cid:6981), सिचव [िव(cid:6980)ापन-III/4/असा./316/2016] पाद (cid:7407)ट(cid:7009)पणी : मु(cid:6990)य िविनयम सं(cid:6990)या सा.का.िन. 612(अ), (cid:7408)दनांक 27 अग(cid:7021)त, 2008 के तहत अिधसूिचत (cid:7263)ए और सा.का.िन.750(अ), (cid:7408)दनांक 14.10.2009, फा.सं(cid:6990)या एम(आई) टी4एस/ सीजी/डी/1/2010 (cid:7408)दनांक 16.12.2014, फा.सं(cid:6990)या एल-िमस/VI/I/2007, (cid:7408)दनांक 01.01.2015 तथा फा. सं(cid:6990)या एम (आई) टी4एस / सीजीडी / 1 /2010 (cid:7408)दनांक 09.04.2016 के तहत संशोिधत (cid:7408)कए गए। PETROLEUM AND NATURAL GAS REGULATORY BOARD NOTIFICATION New Delhi, the 24th November, 2016 F. No. M(I)/T4S/CGD/1/2010.—In exercise of the powers conferred by section 61 of the Petroleum and Natural Gas Regulatory Board Act, 2006 (19 of 2006), the Petroleum and Natural Gas Regulatory Board hereby makes the following regulations to amend the Petroleum and Natural Gas Regulatory Board (Technical Standards and Specifications including Safety Standards for City or Local Natural Gas Distribution Networks) Regulations, 2008, namely:- 1.(cid:32) Short title and commencement. (1)(cid:32) These regulations may be called the Petroleum and Natural Gas Regulatory Board (Technical Standards and Specifications including Safety Standards for City or Local Natural Gas Distribution Networks) Amendment Regulations, 2016. (2)(cid:32) They shall come into force on the date of their publication in the Official Gazette. 2.(cid:32) In the Petroleum and Natural Gas Regulatory Board (Technical Standards and Specifications including Safety Standards for City or Local Natural Gas Distribution Networks) Regulations, 2008, - (i)(cid:32) in Appendix I, serial number 6, under the heading “Critical infrastructure/ activity/ processes”, for “Steel reinforced rubber hose conforming to IS 9573 Type IV.”, the following shall be substituted, namely: - “Steel reinforced rubber hose conforming to IS 9573 Type II.”; (ii)(cid:32) in Appendix I, serial number 9, under the heading “Critical infrastructure/ activity/ processes”, for the words beginning with “Emergency Response Plan, Disaster Management Plan and written emergency procedures...” and ending with “…material safety data sheets etc. at its disposal.”, the following shall be substituted, namely:- “Emergency Response Plan, Disaster Management Plan and written emergency procedures. Also, provide for an Emergency Control Room, manned round the clock and equipped with effective communication system and emergency vehicles equipped or provided with communication facilities, first aid equipment, fire extinguishers, gas detectors, repair kits and tools, maps, plans, material safety data sheets etc. at its disposal.”; (iii)(cid:32) in Schedule 1A, under the heading “Pipes and tubing for above ground service lines up to meter set assembly”, after the words beginning with “The use of copper tubing shall only be after consumer meter such that….” and ending with “….this is not accessible to third party.” , the following shall be added, namely: - “Use of copper pipe / tube before consumer meter should be inside the kitchen only.”; (iv)(cid:32) in Schedule 1A, under the heading “Plastic Pipe and Components”, for the words beginning with “Polyethylene (PE) pipes conforming to IS 14885 or ISO 4437,….” and ending with “….and PE fittings conforming to ISO 8085 Part 3 shall be acceptable.”, the following shall be substituted, namely: - “Polyethylene (PE) pipes conforming to IS 14885 or ISO 4437 and PE fittings conforming to ISO 4437 Part 3 or EN 1555 Part 3 shall be acceptable.”;6 THE GAZETTE OF INDIA : EXTRAORDINARY [PART III—SEC. 4] (v)(cid:32) in Schedule 1A, the heading “Reuse of Ductile Iron Pipes”, and the words under it beginning with “Reuse of ductile….” and ending with “….iron pipes is not permitted.” shall be omitted; (vi)(cid:32) in Schedule 1C, under the heading “Fittings other than Valves and Flanges”, for the words “Thermoplastic fittings conforming to ISO 8085 Part 3 shall be acceptable and shall meet following requirements:”, the following shall be substituted, namely:- “Thermoplastic fittings conforming to ISO 4437 Part 3 or EN 1555 Part 3 shall be acceptable and shall meet following requirements:”; (vii)(cid:32) in Schedule 1C, under the heading “Fittings other than Valves and Flanges”, in sub-paragraph b., the words “Heating element shall not be exposed and all coils are embedded into the body of the fittings.” shall be omitted; (viii)(cid:32) in Schedule 1D, under the heading “CGD network Description”, in the serial numbers iv) and v), the words beginning with “(stream redundancy shall…” and ending with, “…not be less than 2+1) ” shall be omitted; (ix)(cid:32) in Schedule 1D, under the sub-heading “Plastic Pipe and Tubing Design Formula”, for the words beginning with “Nominal wall thickness of plastic pipe…” and ending with “…shall be calculated as per following formula:”, the following shall be substituted, namely:- “The design pressure for plastic gas piping systems or the nominal wall thickness for a given design pressure shall be determined by the following formula:”; (x)(cid:32) in Schedule 1D, under the heading “Design Pressure of Plastic Fitting”, for the words beginning with “All PE fittings shall…” and ending with “…conform to ISO 8085 –Part 3.”, the following shall be substituted, namely:- “All PE fittings shall conform to ISO 4437 Part 3 or EN 1555 Part 3.”; (xi)(cid:32) in Schedule 1D, under the heading “Plastic Pipe and Tubing Joints and Connections”, under the sub-heading “General Provisions”, the words beginning with “Fusion fittings shall have inbuilt…” and ending with “…beyond external clamp system.” shall be omitted; (xii)(cid:32) in Schedule 1D, in the sub-heading beginning with “Control and Limiting of Gas Pressure in High Pressure Steel…” and ending with “….Ductile iron, Cast Iron or Plastic Distribution system.”, the following shall be substituted, namely:- “Control and Limiting of Gas Pressure in High Pressure Steel or PE Distribution System.”; (xiii)(cid:32) in Schedule 1D, under the sub-heading, “Control and Limiting of Gas Pressure in low Pressure Distribution Systems”, the words beginning with “Control and limiting of pressure of gas delivered to domestic, small commercial,…” and ending with “….and small industrial consumers from high – pressure distribution system.” shall be omitted ; (xiv)(cid:32) in Schedule 1D, under the heading “GAS SERVICE LINES”, for the sub-heading, “Installation of Service Lines”, at the end of the paragraph beginning with “All plastic pipe and fittings…” and ending with, “…shall be provided in confined space.”, the following shall be added, namely:- “The depth of cover can be further reduced upto 375 mm provided it meets the following requirements: i.(cid:32) The line pressure shall not exceed 110 mbar. ii.(cid:32) The diameter of pipe shall not exceed 63mm. iii.(cid:32) Pipe shall be laid in a trench with Reinforced Cement Concrete (RCC) slab at the top and bottom. The RCC slab of the roof of basement shall be treated as the bottom. iv.(cid:32) There shall be a sand filling across three sides of the line pipe of 100 mm each. v.(cid:32) RCC on top shall have minimum thickness of 150mm. vi.(cid:32) The top side shall be covered by warning mat. vii.(cid:32) The Quantitative Risk Assessment (QRA) of the site shall be carried out and specific approval from management shall be taken for reducing the depth of cover upto 375mm. viii.(cid:32) The site shall be private property i.e. multi-storey buildings / apartments with no movement of heavy vehicles.”;¹Hkkx IIIµ[k.M 4º Hkkjr dk jkti=k % vlk/kj.k 7 (xv)(cid:32) in Schedule 1E, for the sub-heading “Leakage Surveys”, for the words beginning with “Any one or combination of methods…” and ending with “…described in ASME B 31.8, Appendix M can be adopted based on their effectiveness for the specific areas.”, the following shall be substituted, namely:- “Any one or combination of methods described in ASME B31.8 can be adopted based on their effectiveness for the specific areas.”; (xvi)(cid:32) in Schedule 1E, for the sub-heading “Repair of Plastic Pipe or Tubing”, for the words beginning with “Only repair method allowed is use of full encirclement…” and ending with “…split sleeves which shall be in accordance with ASME B 31.8.”, the following shall be substituted, namely:- “Repair of Plastic Pipe or Tubing shall be in accordance with ASME B31.8.”; (xvii)(cid:32) in Annexure I, under the heading “List of Specifications of Piping Materials used in CGD Network”, in the sub- heading “Valves”, for the words beginning with “BS 5352….” and ending with “…petrochemical and allied industries”, the following shall be substituted, namely:- “BS EN ISO 15761: Steel gate, globe and check valves for sizes DN 100 and smaller, for the petroleum and natural gas industries.”; (xviii)(cid:32) in Annexure I, under the heading “List of Specifications of Piping Materials used in CGD Network”, in the sub- heading “Valves”, for the words beginning with “BS 5351….” and ending with “…Small Floating ball valve”, the following shall be substituted, namely:- “BS EN ISO 17292: Metal ball valves for the petroleum, petrochemical and allied industries.”; (xix)(cid:32) in Annexure I, under the heading “List of Specifications of Piping Materials used in CGD Network”, under the sub-heading “Fittings”, for the words beginning with “IS 1239 (PART-2)….” and ending with “…and other wrought steel pipe fittings”, the following shall be substituted, namely:- “IS 1239 (Part-2): Steel Tubes, Tubular and Other Steel Fittings-Specification-Part 2: Steel pipe fittings.”; (xx)(cid:32) in Annexure I, under the heading “List of Specifications of Piping Materials used in CGD Network”, under the sub-heading “Plastic Valves”, for the words beginning with “EN 10204….” and ending with “…Excess flow check valve”, the following shall be substituted, namely:- “EN 10204: Metallic products- Types of Inspection documents”; (xxi)(cid:32) in Annexure I, under the heading “List of Specifications of Piping Materials used in CGD Network”, for the sub- heading “Brass Fittings”, after the words “IS 319 Free Cutting Leaded Brass Bars, Rods and Sections – Specification”, the following shall be added, namely:- “EN 12164: Copper and copper alloys. Rod for free machining purposes. EN 12165: Copper and copper alloys. Wrought and unwrought forging stock.”; (xxii)(cid:32) in Annexure II, under the heading “List of Specifications for Equipment used in CGD Network”, under the sub- heading “Metering Equipment”, for the words beginning with “OIML R6 / OIML R31….” and ending with “…Diaphragm gas meters”, the following shall be substituted, namely:- “OIML R 137-1&2: Gas meters.”; (xxiii)(cid:32) in Annexure II, under the heading “List of Specifications for Equipment used in CGD Network”, under the sub- heading “Metering Equipment”, the words beginning with “BS 1359 / BS 4161….” and ending with “…Diaphragm gas meters”, the following shall be substituted, namely:- “BS 1359 : Gas meters - Diaphragm gas meters.”; (xxiv)(cid:32) in Annexure II, under the heading “List of Specifications for Equipment used in CGD Network”, under the sub- heading “Metering Equipment”, the words beginning with “OIML R32….” and ending with “…Rotary piston gas meters and turbine gas meters” shall be omitted;8 THE GAZETTE OF INDIA : EXTRAORDINARY [PART III—SEC. 4] (xxv)(cid:32) in Annexure II, under the heading “List of Specifications for Equipment used in CGD Network”, for the sub- heading “Electro fusion machine for jointing PE pipe and fittings”, the following shall be substituted, namely:- “ISO 12176-2: Plastic pipes and fittings- Equipment for fusion jointing polyethylene systems- Part 2: Electrofusion. EMC Standards EN-55014: Limits and methods of measurement of radio disturbance characteristics of electrical motor operated and thermal appliances for household and similar purposes, electric tools and similar electric apparatus EN 61000-6-3: Electromagnetic compatibility (EMC): Generic standards- Emission standard for residential, commercial and light-industrial environments EN 61000-6-1: Electromagnetic compatibility (EMC): Generic standards- Immunity for residential, commercial and light-industrial environments EN-61000-3-2: Electromagnetic compatibility (EMC): Limits- Limits for harmonic current emissions (equipment input current < 16 A per phase) EN-60335-1: Household and similar electrical appliances: Safety- General requirements EN-60335-2-45: Household and similar electrical appliances: Safety- Particular requirements for portable heating tools and similar appliances”; (xxvi)(cid:32) in Annexure IV, under the heading, “Minimum Requirements for GI Pipes and Copper Tubing used in service lines up to consumer appliance”, under the sub-heading “Copper Tubing”, the words beginning with “Fittings for use in joining copper tube shall be…” and ending with “…as per BS EN 1254 Parts 1 and 2.” shall be omitted. (xxvii)(cid:32) in Annexure IV, under the heading, “Minimum Requirements for GI Pipes and Copper Tubing used in service lines up to consumer appliance”, for the sub-heading “Copper Tubing”, for the words beginning with “Filler metals shall be…” and ending with “…as per BS EN 29453:1994 - Soft solders alloys - Chemical compositions and forms.”, the following shall be substituted, namely:- “Filler metals shall be as per BS EN ISO 9453: Electromagnetic compatibility (EMC). Generic Standards. Immunity for residential, commercial and light industrial environments.”. VANDANA SHARMA, Secy. [ADVT-III/4/Exty./316/2016] Foot Note : Principal regulations were notified vide No. G.S.R. 612(E), dated 27th August, 2008. Amended vide G.S.R. 750(E) dated 14-10-2009. F. No. M(I)/T4S/CGD/1/2010 dated 16-12-2014, F. No. L-MISC/VI/I/2007 dated 01.01.2015 and F. No. M(I)/T4S/CGD/1/2010 dated 09.04.2016. Uploaded by Dte. of Printing at Government of India Press, Ring Road, Mayapuri, New Delhi-110064 and Published by the Controller of Publications, Delhi-110054.

Continue your research