See Full Document Text
Annexure-I
भारतीय दू रसंचार विवियामक प्राविकरण
Telecom Regulatory Authority of India
(IS/ISO 9001-2015 Certified Organisation)
Draft Manual for Assessment of Digital
Connectivity under
Rating of Properties for Digital Connectivity
Regulations, 2024
1PREFACE
The digital technology innovations have fundamentally reshaped modern society, transforming
communication, work, and our interaction with the environment. As our reliance on seamless
connectivity intensifies, robust and reliable digital infrastructure within properties has
transitioned from a desirable amenity to an indispensable utility. This encompasses high-
bandwidth internet for remote work, ubiquitous mobile coverage for daily communication, and
intelligent building systems that optimize energy efficiency and security through real-time data
exchange.
However, many existing and newly constructed properties encounter significant obstacles in
achieving comprehensive digital connectivity. These challenges stem from factors such as legacy
infrastructure, inadequate planning, and a lack of standardized deployment practices, impeding
residents and businesses from fully leveraging the advantages of a digitally interconnected
world. Recognizing these critical gaps, the TRAI regulations on "Rating of Properties for Digital
Connectivity Regulations, 2024." is aimed at providing the rating framework for digital
connectivity within buildings or properties.
This regulation provides a framework to address these challenges by promoting uniform
standards, fostering collaboration among stakeholders, and incentivizing the adoption of future-
proof technologies. By establishing clear rating framework, these regulations ensure that
connectivity infrastructure, including provisions for adequate bandwidth, low latency, and
robust signal strength, is integrated as a fundamental component of property development.
We encourage all stakeholders viz. policymakers, developers, architects, telecom service
providers, and the consumers, to collaborate in realizing this vision, shaping a future where
ubiquitous connectivity is a tangible reality for everyone. The regulation aims to foster an
ecosystem where Digital Connectivity Infrastructure (DCI) is co-created as an integral part of
any development activity.
This rating manual will serve as a reference to the Digital Connectivity Rating Agencies (DCRAs),
property managers, architects, digital infrastructure providers and service providers to plan and
implement seamless digital connectivity infrastructure for seamless user experience.
2Table of Contents
Abbreviations .................................................................................................................................. 6
1. Introduction .............................................................................................................................. 7
1.1. Overview ............................................................................................................................ 7
1.2. Importance of Digital Connectivity ........................................................................... 7
1.3. Background and Purpose ............................................................................................. 8
1.4. Digital Connectivity Rating Framework.................................................................. 9
1.5. Objectives of the Rating Manual .............................................................................. 10
1.6. Scope of the Rating Manual ....................................................................................... 10
2. Role of Stakeholders ........................................................................................................ 12
2.1. Digital Connectivity Rating Agency (DCRA) ........................................................ 12
2.2. Property Manager (PM) .............................................................................................. 13
2.3. Telecom Service Providers (TSPs) .......................................................................... 14
2.4. Digital Connectivity Infrastructure Providers (DCIPs) ................................... 14
2.5. Consumers/ End Users ................................................................................................15
3. Registration Process and Rating Lifecycle ................................................................17
3.1. Eligibility Criteria of Digital Connectivity Rating Agency (DCRA)
Registration ................................................................................................................................. 17
3.2. Registration Process of DCRA ................................................................................... 17
3.3. General Obligations for DCRA.................................................................................. 19
3.4. Registration of Property Manager .......................................................................... 19
3.5. General Obligations for Property Manager ......................................................... 19
3.6. Classification of Properties for Rating .................................................................. 20
3.7. Rating Process................................................................................................................ 21
4. Assessment Methodology for Category ‘A’ Properties ......................................... 26
4.1. Compliance to Applicable Model Building Bye Laws (MBBL) and National
Building Code (NBC) for Digital Connectivity ................................................................ 29
4.2. Provision in Civil Infrastructure, over and above MBBL and NBC
requirements, for Ensuring Robust Digital Connectivity ........................................... 33
4.3. Provision in Power Infrastructure, over and above MBBL or NBC
requirements, for Ensuring Reliable Digital Connectivity ......................................... 38
4.4. Digital Connectivity Infrastructure Resilience ................................................... 44
4.5. Future Readiness of Digital Connectivity Infrastructure................................ 49
4.6. Provision of Wired Connectivity Infrastructure ................................................ 53
34.7. Availability of Service Providers .............................................................................. 58
4.8. Service Performance.................................................................................................... 61
4.9. User Experience ............................................................................................................ 68
4.10. Summary of Rating Score....................................................................................... 70
5. Assessment Methodology for Category ‘B’ Properties ......................................... 74
5.1. Provision in Power Infrastructure for Ensuring Reliable Digital
Connectivity ................................................................................................................................ 76
5.2. Digital Connectivity Infrastructure Resilience ................................................... 81
5.3. Future Readiness of Digital Connectivity Infrastructure................................ 86
5.4. Provision of Wired Connectivity Infrastructure ................................................ 91
5.5. Availability of Service Providers .............................................................................. 95
5.6. Service Performance.................................................................................................... 99
5.7. User Experience .......................................................................................................... 106
5.8. Summary of Rating Score ........................................................................................ 108
6. Award of Rating and Renewal ..................................................................................... 111
6.1. Classification of Ratings ............................................................................................ 111
6.2. Validity Period of Ratings ......................................................................................... 111
6.3. Reassessment Process ................................................................................................ 112
6.4. Renewal Process........................................................................................................... 113
7. Reporting and Feedback Mechanism ............................................................................ 115
7.1. Monitoring and Reporting Mechanism ................................................................ 115
7.2. Mechanism for Stakeholder Feedback ................................................................. 115
7.3. Addressing Non-Compliance ................................................................................... 116
8. Appeal Process .................................................................................................................. 117
8.1. Filing of Appeal by Property Manager .................................................................. 117
8.2. Review of Appeal by DCRA ....................................................................................... 117
8.3. Escalation of Appeal to the Authority ................................................................... 118
8.4. Examination of Appeal by Authority ..................................................................... 118
9. Review and Updates of Rating Manual ..................................................................... 119
9.1. Process for Periodic Updates ................................................................................... 119
10. Best Practices for Digital Connectivity in Properties ......................................... 120
10.1. Best Practices for Digital Connectivity ............................................................ 120
410.2. Integration of Connectivity Infrastructure in Design and Construction
123
10.3. Collaboration with stakeholders ....................................................................... 123
11. Appendix ............................................................................................................................ 125
11.1. Frequently Asked Questions (FAQ) ...................................................................... 125
11.2. List of Applicable Standards and References .................................................... 128
11.3. Documents Checklist ................................................................................................. 128
11.4. User Feedback Form .............................................................................................. 136
11.5. Template for declaration of maximum chargeable fee by DCRA (As per
regulation) .................................................................................................................................137
5Abbreviations
Acronyms Description
BIS Bureau of Indian Standards
BMS Building Management System
DAS Distributed Antenna System
DCI Digital Connectivity Infrastructure
DCIP Digital Connectivity Infrastructure Provider
DCRA Digital Connectivity Rating Agency
DTH Direct to Home
DWDM Dense Wavelength Division Multiplexing
ICT Information and Communications Technology
IoT Internet of Things
IBS In Building Solutions
IP Infrastructure Provider
M2M Machine to Machine Communication
MBBL Model Building Bye Laws
MOHUA Ministry of Housing and Urban Affairs
MOS Mean Opinion Score
NBC National Building Code
NDCP National Digital Communication Policy
PM Property Manager
PON Passive Optical Network
QoE Quality of Experience
QoS Quality of Service
SON Self-Optimizing Networks
TEC Telecom Engineering Center
TRAI Telecom Regulatory Authority of India
TSP Telecom Service Provider
UPS Uninterrupted Power Supply
WFA Work From Anywhere
WFH Work from Home
61. Introduction
1.1. Overview
Internet access serves as a critical enabler, connecting individuals and businesses to
governments, markets, and a wide range of economic and social opportunities. Digital
services, including e-payments, e-commerce, and e-identification, are revolutionizing
business models across sectors such as financial services, healthcare, and education, while
also transforming the delivery and consumption of goods throughout the broader economy.
Emerging technologies like Internet of Things (IoT) and Artificial Intelligence (AI) have the
potential to further accelerate the growth of the digital economy. In emerging markets, digital
connectivity has been a significant driver of development over the past two decades, fostering
economic growth, job creation, and poverty reduction. By expanding markets, improving
efficiency in both business and government operations, and driving innovation in traditional
sectors, digital technologies are unlocking new opportunities for inclusive development.
However, the benefits of digital connectivity cannot be fully realized without universal access
to the Internet. Significant progress has been made over the past two decades to increase the
reach of telecommunication networks, with 90 percent of the world population covered by a
mobile broadband network.
1.2. Importance of Digital Connectivity
The development of resilient, world-class infrastructure—physical, social, financial, and
digital—forms a cornerstone of India’s strategy to achieve the vision of Viksit Bharat @ 2047.
Among these, digital infrastructure has emerged as a critical necessity, often rivaling
traditional infrastructure components such as power, water, and transportation. The COVID-
19 pandemic not only reshaped the global order but also accelerated the expansion of digital
infrastructure worldwide. Comprising the physical resources and systems required to process
and utilize data effectively; digital infrastructure has become essential to societal functioning
and quality of life. As nations aim to make their digital systems more resilient, agile, and
forward-looking, India, with its vast population and technological potential, is well-
positioned to assume a leadership role in shaping the future global digital landscape.
The rapid advancement of technologies such as 4G and 5G, coupled with enabling devices
and software applications, has profoundly transformed both personal and professional lives
while reshaping governance and business models globally. Today, individuals across all age
groups increasingly rely on smart devices for activities such as studying, working, and
entertainment. The availability of online services, including banking, e-commerce, citizen-
centric solutions, and infotainment options like gaming and social networking, hinges on
robust digital connectivity. In the modern era, it is almost unimaginable to function without
access to these services, emphasizing the critical need for reliable and high-quality digital
connectivity.
7India’s digital transformation holds immense promise, with nearly ~944 Mn internet users
as of 28th February 2025 and a growing ecosystem of indigenous digital services, platforms,
and applications. This digital transformation could unlock significant opportunities for
businesses, startups, and innovators to invest in emerging technologies like AI, blockchain,
and drones tailored to India’s unique needs. However, the rapid adoption of frontier
technologies has placed tremendous pressure on existing digital infrastructure. To harness
the full potential of initiatives such as Smart Cities and Smart Health, focus on augmenting
and modernizing digital infrastructure is essential to sustain this momentum and enable the
seamless integration of advanced technologies into its digital infrastructure.
1.3. Background and Purpose
The purpose of the rating framework is to establish a standardized framework to assess the
availability of digital connectivity infrastructure in different categories of properties and to
encourage the stakeholders to improve the telecom network quality of service in properties.
The aim is to improve consumer experience, ensure seamless digital connectivity, and
promote stakeholder collaboration, making Digital Connectivity Infrastructure (DCI) an
integral part of property development. The quality of telecommunication services inside the
properties is an integral part of protection of consumer interest.
To provide legal and regulatory trigger for addressing the issue of accessibility and quality of
digital connectivity inside properties, the Telecom Regulatory Authority of India has
submitted recommendations to the Government on “Recommendations on Rating of
Buildings or Areas for Digital Connectivity” dated 20th February 2023 and regulation on
“Rating of Properties for Digital Connectivity,2024” dated 25th October 2024. The
recommendations and regulations are aimed at creating an ecosystem for co-creations of
Digital Connectivity Infrastructure (DCI) as a part of any development activity, be it a Building
or an Area
The key objectives of regulation on “Rating of Properties for Digital Connectivity,2024”,
hereunder referred as the regulation, includes:
a. To improve consumer experience by ensuring seamless connectivity inside properties
b. To standardize and promote high-quality digital connectivity in residential, commercial,
and public properties
c. To provide a standardized rating system to evaluate properties for their digital
infrastructure and service readiness
d. To provide prospective tenants, owners, and businesses with transparent measure of
quality of property’s digital connectivity
e. To encourage coordination between property managers, Service Providers, DCIPs to
implement connectivity standards.
8The regulation is applicable for:
i. Property managers who intend to get their property, of minimum specified size, rated
for digital connectivity, either voluntarily or under the provisions of applicable laws,
rules or regulations
ii. Digital connectivity rating agencies (DCRA), who may evaluate and award ratings for
property under these regulations; and
iii. Service providers, who may enter an arrangement with the property manager for
development or access of digital connectivity or digital connectivity infrastructure.
1.4. Digital Connectivity Rating Framework
The regulation provides a standardized method to evaluate digital connectivity inside
properties. The ratings, provided under the rating framework under the regulation, will enable
stakeholders to make informed choices while promoting the development of robust digital
infrastructure. The key aspects of rating framework include:
i. Standardized Process
The framework establishes a uniform methodology to assess the digital connectivity of
properties and areas across various categories, ensuring comparability and reliability.
Properties shall be evaluated based on defined parameters in the regulation such as fiber
readiness, mobile network availability, in-building solutions and Wi-Fi infrastructure.
Different property types (commercial, residential, industrial, public spaces, hospitals,
government offices, transport corridors and many more) may have tailored benchmarks
to ensure relevant and fair assessments.
ii. Consistent Quality and Coverage
Integrating Digital Connectivity Infrastructure (DCI) at an early stage in property
development ensures that digital services are of high quality, reducing connectivity gaps
and enhancing user experience. The framework promotes the inclusion of diverse
connectivity options, such as fiber optic networks, Wi-Fi, cellular connectivity and
satellite broadband, to enhance resilience Properties will be assessed based on their
capability to provide seamless indoor and outdoor network coverage, including
provisions for small cells, DAS (Distributed Antenna Systems) and Wi-Fi network.
iii. Consumer Empowerment
A structured rating system enables consumers and stakeholders to make informed
decisions based on digital connectivity performance, driving competitive improvements.
9a. Informed decision-making: Prospective tenants and buyers can compare
properties based on their connectivity rating, ensuring they choose locations with the
best digital infrastructure.
b. Market differentiation: Property managers and consumers are incentivized to
enhance their digital infrastructure to achieve higher ratings, improving property
value and marketability.
c. Future readiness: Encourages property managers to adopt emerging technologies
to future-proof their properties.
1.5. Objectives of the Rating Manual
The Rating Manual serves as a structured framework designed to ensure a fair, transparent,
and standardized approach to assessing digital connectivity under the provisions of the
regulation.
1.6. Scope of the Rating Manual
The Rating Manual outlines the detailed methodology to be followed by the stakeholders for
assessment of digital connectivity in different categories of properties as per the assessment
criteria provided in the "Rating of Properties for Digital Connectivity Regulations, 2024". This
document provides a comprehensive guide for all stakeholders involved in implementation
and assessment of digital connectivity in properties and areas, including Digital Connectivity
Rating Agency (DCRA), Property Manager (PM), and Service Providers.
Key aspects of the manual include a detailed description of the overall rating process for
digital connectivity. This process encompasses the registration procedures for DCRAs and
property managers. It also specifies the evaluation methodology tailored for distinct property
classifications provided in the regulation i.e. Category A properties and Category B properties.
The manual also elaborates on the processes for the award and renewal of ratings.
Additionally, it sets forth provisions for a reporting and feedback mechanism, empowering
stakeholders to provide input for maintaining and improving the rating framework. Processes
for dispute resolution are also detailed, offering structured processes to address and resolve
conflicts among stakeholders effectively.
Recognizing the dynamic nature of digital connectivity needs, the manual provides a protocol
for the periodic review and updates of the rating manual. This ensures that the manual
remains relevant in addressing technological advancements, changing user expectations, and
emerging challenges. The manual also includes a section dedicated to guidelines and best
practices to be adhered to by property managers and DCRAs, fostering consistency and quality
in the implementation of digital connectivity standards.
This rating manual provides processes and methodology for assessment of digital connectivity
under the "Rating of Properties for Digital Connectivity Regulations, 2024". In case of any
discrepancy or interpretation, the provision of the regulations shall prevail.
10112. Role of Stakeholders
The following subsections provide an overview of roles of key stakeholders within the
ecosystem including the digital connectivity rating agency, property manager, telecom service
provider, and digital connectivity infrastructure provider.
2.1. Digital Connectivity Rating Agency (DCRA)
DCRAs play a critical role in evaluating and certifying the quality, reliability, and readiness
of digital connectivity in the properties. The responsibilities of DCRA, as per the regulations,
include:
i. Evaluation of property for digital connectivity: Conduct thorough assessments
of the digital connectivity in properties including fiber-optic availability, mobile
network coverage, Wi-Fi accessibility, and broadband reliability and use established
criteria to evaluate the digital connectivity.
ii. Issuance of ratings: Assign objective and transparent ratings based on the
evaluation results, providing property managers and stakeholders with a clear
indication of connectivity infrastructure and service performance. Generate official
rating certificates that property managers can use to demonstrate their digital
connectivity standards to tenants, investors, and businesses. DCRA ensures that
ratings reflect real-world digital connectivity experiences, helping end-users make
informed decisions about properties based on their digital connectivity requirements
and available performance.
iii. Feedback and recommendations: Provide constructive feedback to property
managers on areas for improvement in their digital connectivity infrastructure or
services and indicate best practices and enhancements to help property managers
achieve higher ratings.
iv. Collaboration with stakeholders: Work closely with property managers, service
providers and infrastructure providers to gather necessary data for evaluations and
maintain communication with TRAI to ensure compliance with regulatory standards.
v. Continuous improvement: Stay updated on technological advancements and
regulatory changes to refine evaluation criteria and participate in training and
workshops to enhance evaluation methodologies. Participate in training programs,
workshops, and knowledge-sharing initiatives to enhance evaluation methodologies
and improve accuracy in assessments.
12vi. Reporting: Maintain comprehensive records of all evaluations conducted, ratings
issued, and feedback provided to property managers for different properties. Submit
periodic reports and trend analyses to TRAI, highlighting industry-wide connectivity
performance, key challenges, and areas needing regulatory attention.
vii. Compliance with Regulations: All the DCRA activities shall be within the
framework of the regulations and directions or orders or guidelines issued from time
to time by the Authority.
2.2. Property Manager (PM)
As defined in the regulations, the “Property Manager” means the person who is either the
owner of the property to be rated for digital connectivity or has any legal right to control or
manage the property. The Property Manager plays a key role in facilitating digital connectivity
assessments, coordinating with relevant authorities, and implementing improvements to
enhance user experience and maintain compliance with regulatory standards. Property
Managers are responsible for overseeing the management and maintenance of properties,
including ensuring adequate digital connectivity. The responsibilities of Property Manager,
under the regulations, inter-alia, include:
i. Application for ratings:
a. Submit applications for digital connectivity ratings through the rating portal and
provide accurate and comprehensive information about the property’s digital
connectivity.
b. Provide accurate and comprehensive information regarding the property’s existing
digital connectivity infrastructure, including network coverage, fiber availability,
and telecom service provider details.
c. Ensure that all submitted data is up to date and reflects the actual service available
on the property.
ii. Documentation and compliance:
a. Prepare and upload the necessary documentation required for the evaluation
process and ensure ongoing compliance with standards set by DCRAs and TRAI.
b. Keep track of changes in compliance requirements and implement necessary
updates to avoid penalties or service disruptions.
iii. Maintenance of digital connectivity infrastructure:
a. Regularly inspect and maintain the digital connectivity infrastructure to ensure
optimal performance and address any connectivity issues promptly to maintain
service quality.
b. Address connectivity issues proactively by working with telecom service providers
and technical support teams.
13c. Ensure proper maintenance and upgrades of network equipment to optimize
performance and provide a seamless digital experience for occupants and tenants.
iv. Collaboration with DCRAs:
a. Facilitate the evaluation and rating process by providing Digital Connectivity
Rating Agencies (DCRAs) with necessary access to the property.
b. Work closely with evaluators to share technical data, network reports, and other
relevant details needed for the rating assessment.
c. Implement recommendations and best practices suggested by DCRAs to enhance
the property's digital connectivity rating.
v. Customer communication and tenant engagement:
a. Act as the primary point of contact for tenants and occupants regarding digital
connectivity services within the property.
b. Address concerns or complaints related to network performance and ensure that
users are informed about available connectivity solutions and upgrades.
Educate tenants on digital connectivity features available in the property and
promote initiatives aimed at improving network access and reliability.
2.3. Telecom Service Providers (TSPs)
TSPs are entities responsible for delivering a wide range of telecommunications and digital
services, including mobile and fixed-line communication, internet access, and broadband
services. They serve as the backbone of digital connectivity, ensuring seamless and reliable
communication for end-users. Their role is critical in maintaining and improving the overall
quality of digital services, directly impacting the user experience and the effectiveness of
digital infrastructure. The TSPs are encouraged to collaborate with the property managers
and DCIPs for extending and maintenance of digital connectivity in the properties.
2.4. Digital Connectivity Infrastructure Providers (DCIPs)
Digital Connectivity Infrastructure Providers are entities that develop and maintain the
digital infrastructure as per their authorization. This includes network equipment, cabling,
and other technological frameworks.
Digital Connectivity Infrastructure Providers (DCIPs) are key enablers in the
telecommunication and digital ecosystem, responsible for developing, deploying, and
maintaining the physical and digital infrastructure that supports seamless digital
connectivity services. Their role is vital in ensuring high-speed, reliable, and future-ready
network infrastructure that caters to the growing demands of consumers, businesses, and
service providers.
14The responsibilities of DCIP are as follows:
i. Infrastructure development: Design, build, and maintain the digital
communication infrastructure necessary for reliable connectivity and ensure that the
infrastructure meets the technical specifications required for high-speed digital
services.
ii. Compliance with standards: Ensure that all infrastructure complies with
standards set by regulatory bodies and industry best practices and regularly update
infrastructure to keep up with technological advancements and regulatory changes.
iii. Maintenance and upgrades: Conduct regular maintenance of infrastructure to
ensure optimal performance, plan and execute upgrades to enhance capacity and meet
evolving demands for digital services.
iv. Customer collaboration: Work closely with Telecom Service Providers to ensure
that the infrastructure meets their service delivery needs and address any issues
related to infrastructure that may impact service quality.
v. Feedback mechanism: Participate in feedback mechanisms to improve
infrastructure quality based on ratings and assessments from DCRAs and implement
necessary changes based on feedback to enhance the overall connectivity experience.
2.5. Consumers/ End Users
The consumer or end-user is the primary stakeholder in the broader ecosystem for assessing
and rating digital connectivity in properties or specific geographical areas. Their role is
pivotal, as the quality and reliability of connectivity directly impact their daily digital
interactions, productivity, and overall satisfaction.
The fundamental objective of implementing a rating system is to enhance the quality of
service and thereby experience (QoE) for consumers by identifying gaps in connectivity and
encouraging improvements in digital infrastructure. To achieve this, user feedback and real-
world end-user experiences must be integral components of the rating framework, ensuring
that assessments reflect actual usability.
The quality of user experience can be measured objectively through various technical key
performance indicators (KPIs). These include parameters such as network latency, download
and upload speeds, signal strength, coverage consistency, etc. These metrics collectively
define the Quality of Experience (QoE) from a technical standpoint and provide quantifiable
data to assess digital connectivity standards.
On the other hand, subjective evaluation of QoE involves gathering consumer perceptions
through structured methods such as end-user surveys, real-time feedback mechanisms, and
15digital reporting platforms. This qualitative input helps capture aspects of user experience
that may not be fully reflected in technical measurements, such as service reliability, ease of
connectivity, and user satisfaction with network performance.
By combining both objective technical assessments and subjective user feedback, the rating
framework can provide a holistic evaluation of digital connectivity in properties and areas,
ultimately driving improvements that align with consumer expectations and technological
advancements.
163. Registration Process and Rating Lifecycle
The rating lifecycle begins with the registration of the Digital Connectivity Rating Agency
(DCRA) and property managers, ensuring adherence to established terms and conditions.
Following this, properties are mapped to the categories provided in the regulations for the
assessment process. The assessment phase involves a comprehensive review of the digital
connectivity infrastructure and services in the properties against set benchmarks, verifying
compliance with regulatory and operational standards. Only after completing the evaluation
steps, the final rating is awarded providing a transparent and standardized measure of digital
connectivity.
3.1. Eligibility Criteria of Digital Connectivity Rating Agency (DCRA)
Registration
An entity shall be eligible for registration as a Digital Connectivity Rating Agency (DCRA)
under regulation if it meets the criteria outlined in (Section III – "Registration of Digital
Connectivity Rating Agency" of the Regulation on Rating of Properties for Digital
Connectivity). The eligible entities may apply for registration as DCRA as per the guidelines
issued by the Authority from time to time.
3.2. Registration Process of DCRA
The registration process for Digital Connectivity Rating Agencies (DCRA) is outlined under
Section III – "Registration of Digital Connectivity Rating Agency" in the Regulation on Rating
of Properties for Digital Connectivity,2024 as amended from time to time. The process
ensures that only eligible and competent entities can participate in property rating activities.
The registration process, as provided in the regulations, is summarized below:
i. Any entity fulfilling the eligibility criteria under regulation and intending to
commence activity as DCRA under the regulations, shall make an application to the
Authority for grant of registration on the rating platform in the manner and format,
and upon payment of such fee, as may be specified by the Authority
ii. An application for registration, which is not complete in all respects or does not
conform to the eligibility criteria specified under regulation or the instructions
specified by the Authority from time to time, shall be rejected:
Provided that before rejecting any such application, the applicant shall be given an
opportunity to rectify the deficiency, if any, within thirty days from the date of receipt
of communication from the Authority;
17Provided further that the Authority may, for sufficient reasons, extend the time for
rectification of the deficiency by such time as it may be considered appropriate, but
such extended time shall not exceed thirty days.
iii. The Authority may, if it so desires, ask the applicant to appear before it, in person, in
connection with the grant of registration.
3.2.1 Grant of Registration and Listing on Rating Platform
The registration and listing process of DCRA on the rating platform is provided in regulation
(6) as summarized below:
i. Eligible applicants meeting the eligibility criteria under regulation will be granted
registration on the rating platform for a period of five years. However, the registration
granted under sub-regulation shall be subject to payment of such fees and such terms
and conditions, as may be specified by the Authority from time to time, by order or
direction.
ii. The registration granted under sub-regulations shall be valid for the specified period
unless it is suspended or cancelled by the Authority as per provisions of these
regulations, or upon approval of the request of DCRA for withdrawal of its registration
by the Authority.
iii. Such registration shall not confer any right upon the DCRA for assignment of work for
rating of property.
iv. The Authority may, upon the request of DCRA and on being satisfied with its
performance, subject to the DCRA meeting the eligibility criteria, renew the
registration of DCRA for another five years.
v. However, in case of non-renewal of its registration by the Authority, DCRA shall
continue to discharge its obligations under the regulations for the remaining validity
period of its registration.
vi. If the applicant or DCRA submits information which is found to be false or misleading
at any stage, either prior to the registration or during the validity of the registration,
the Authority shall, without prejudice to its rights under any law, Act or regulations,
reject the application for registration or cancel or suspend the registration of DCRA.
However, no order for cancellation or suspension of registration shall be made by the
Authority unless DCRA has been given a reasonable opportunity of representing
against such cancellation or suspension by the Authority.
183.2.2 Conditions of Registration for DCRA
The registration of DCRA shall be subject to the conditions prescribed under (Section III –
"Registration of Digital Connectivity Rating Agency" of the Regulation on Rating of
Properties for Digital Connectivity).
3.3. General Obligations for DCRA
DCRA is required to follow a set of terms and conditions prescribed under Section – IV
“General Obligations of DCRA” of “Regulation on Rating of Properties for Digital
Connectivity”. These terms ensure transparency, accountability, and compliance in the rating
process and cover the following aspects:
i. Code of Conduct.
ii. Disclosure of fees and other terms and conditions to the property manager.
iii. Evaluation and award of ratings.
iv. Monitoring of ratings.
v. Retention of records and audit of DCRA.
3.4. Registration of Property Manager
The registration of a Property Manager on the rating platform is an important step in ensuring
that only eligible and authorized individuals or entities can apply for property ratings related
to digital connectivity. This process is governed by the regulation under Section V – General
Obligations of Property Manager. The process for registration is summarized below:
i. Any property manager, who intends to apply for a rating of their property for digital
connectivity under these regulations, shall register himself on the rating platform, in
such manner and format and upon payment of such fees, as may be specified by the
Authority.
ii. No property manager, who is not registered on the rating platform, shall be eligible
to apply for the rating of property being used, controlled or managed by him, in
accordance with the provisions of these regulations.
iii. If the property manager submits any false or misleading information, undertaking,
declaration or documents under this regulation, it shall amount to the contravention
of the provisions of the regulations and the authority may take action as per applicable
laws, Act or regulations.
iv. The fees for rating of property shall be mutually decided by DCRA and the property
manager as provided under regulation.
3.5. General Obligations for Property Manager
The general obligations of a Property Manager are provided in Section V – General
Obligations of Property Manager. These obligations broadly cover the following aspects:
i. Facilitation and co-operation during rating process and inspection.
ii. Compliance of terms and conditions of rating certificate.
19iii. Compliance to approved DCI design.
iv. Repair and maintenance of DCI.
v. Renewal of ratings.
vi. No exclusive arrangement with the service providers.
vii. Fair use of ratings.
viii. Change of property manager or ownership and continuity of DCI.
3.6. Classification of Properties for Rating
The classification of properties for the purpose of rating is one of the key aspects of the
regulations. It provides a structured framework to assess and categorize properties based on
their digital connectivity and ensure a standardized rating system for different types of
properties.
The classification considers property type, usage, digital infrastructure availability, and the
expected connectivity demand to create a fair and transparent rating mechanism.
Below is the detailed classification of properties as provided in Section II of the regulation:
Category
S. No. Classification or Type of Property
Group
Apartments, independent houses, gated
1. Residential A
communities or societies, etc.
All properties of the Central Government, the
Government State Government, Courts, Public Sector
2. A
Properties Undertakings, Local Bodies, Heritage Sites,
etc.
Commercial office complex, shopping malls,
Commercial
3. A industrial estates, SEZs, multi-modal logistic
Establishments
parks, convention centres, etc.
Airport, Bus Station, Railway Station,
Other private
4. B Hospitals, Hotels, Educational Institutions,
or public areas
etc.
Stadiums or
Sport Arenas or Stadiums or permanent spaces of gathering
5. spaces of B with seating capacity of more than 5000
frequent persons
gathering
20Category
S. No. Classification or Type of Property
Group
Transport
6. B Expressways, Highways, Railways routes, etc.
corridors
Table 3.1: Classification of Properties for Rating of digital connectivity
Category A: includes properties that require consistent, high-quality connectivity for daily
operations and business activities.
Category B: includes high-footfall areas and event spaces that require scalable connectivity
solutions based on demand.
3.7. Rating Process
The rating process for digital connectivity in properties follows a structured, multi-stage
evaluation approach to ensure transparency, consistency, and reliability in assessing a
property’s digital capabilities. This framework is designed to evaluate service quality,
infrastructure readiness, and user experience, ultimately assigning a rating that reflects the
property’s ability to support digital connectivity efficiently. The following steps outline the
rating lifecycle and role of DCRA and Property Manager:
i. Online Registration by DCRA and Property Managers: As already outlined
in Section 3.2 and Section 3.4 of this manual, the interested DCRA and Property
Managers need to register on the online rating platform. A one-time and non-
refundable registration fee, as prescribed by the Authority, must be paid by the
property manager at the time of registration. The registration enables Property
Managers to apply for a rating assessment of their properties. The property manager
may also apply for the rating of under construction properties to enable assessment
and guidance by DCRA on implementation of DCI in line with the provision.
However, the rating certificate shall be issued after provisioning DCI as per the
requirement of the regulation for rating criteria.
ii. Submission of Documents:
a. Property Managers seeking a new rating or renewal of an existing rating for the
property shall submit an online application along with the prescribed supporting
documents.
b. A document checklist, including for fully constructed and under construction
properties, will be available in the Frequently Asked Questions (FAQ) section on
the rating portal.
21c. Once application for rating is submitted by the property manager, the system will
generate a Unique Request Identification Number (URIN) for tracking the
application status.
d. The Property Manager can select any of the registered DCRA from the list
provided on the rating platform.
e. The details of the maximum chargeable fee (MCF), to be charged by different
DCRAs, will be available on the portal.
f. Online application of the Property Manager will be automatically assigned to the
Digital Connectivity Rating Agency (DCRA) selected during the submission of
application for rating.
iii. Due-Diligence Stage I:
a. The selected DCRA shall conduct Stage I of due diligence to assess basic
requirements for assessing the digital connectivity status of the property based
on the submitted documents.
b. This stage of assessment must be completed in a time bound manner within 30
days from the date of assignment of the property to the DCRA.
c. If additional details or clarifications are required, the DCRA will notify the
Property Manager to complete the application through the rating platform.
d. The Property Manager should provide relevant inputs to the DCRA within 7 days
of the request by the DCRA failing which the delay will be attributed to the
property manager and not to the DCRA.
e. All the requests and responses for seeking the inputs or clarifications shall be
made through the rating platform.
f. The DCRA will visit the site, at suitable stage(s) of construction, in case the site
is under development or construction to assess whether the DCI is in line with
the approved design. The DCRA will provide its inputs to the property manager
for construction of DCI aligned with requirements of rating criteria as far as
possible.
22iv. Preliminary evaluation comments and action points:
The DCRA shall share their comments with action items, if any, to the Property
Manager concerned through the rating platform. The actions points shall be
classified broadly in three categories as follows:
a. Mandatory: These action points will only include the actions required by
Property Manager without which the evaluation process cannot proceed to next
stage.
b. Recommended: These action items will include those points which may affect
the rating score and consequently the rating of the property. The Property
Manager may choose to ignore these comments and may confirm proceeding for
the next stage of evaluation.
c. Optional: This category of action items will include suggestive actions to be
taken by the Property Manager which does not affect the score and rating of the
property. However, such actions may further improve quality of service and
consumer experience.
v. Corrective action by property manager:
a. In response to the action points arising out of ‘Preliminary evaluation’, the
Property Manager shall take remedial actions on mandatory points to proceed
for second stage of evaluation.
b. After all the ‘Mandatory’ action points are complied, the Property Manager can
apply for second stage of evaluation i.e., Due-Diligence Stage-II. However, the
property managers are encouraged to consider action on recommended and
optional inputs from DCRA to get the best possible score for their property.
vi. Due-Diligence Stage II:
a. The request for initiation of Due Diligence stage-II shall commence upon the
request of the property manager after the action has been completed on at least
‘Mandatory’ action points or preferable other recommended and optional points.
b. The Due Diligence stage-II will involve the process of onsite verification of digital
connectivity and associated infrastructure by the DCRA against the prescribed
rating criteria including as provided in supporting documents.
c. The detailed methodology for scoring against each criterion and sub-criteria and
respective weightage are provided in Chapter-4 of this manual.
23d. The Due Diligence Stage-II will be completed by the DCRA in a time-bound
manner preferable within 60 days of submission of request by the Property
Manager for Due Diligence-II evaluation.
e. The Due Diligence stage-II for under construction will commence on completion
of DCI construction, testing and integration.
vii. Final Evaluation by DCRA:
a. After the completion of Due Diligence stage - II, the DCRA shall consolidate all
the relevant details and prepare a comprehensive assessment report. The
assessment report shall cover the list of all documents collected; the summary
criteria and sub-criteria wise comments, documents, score awarded, and list of
test/evidence collected during the assessment.
b. The objective of each sub-criteria, methodology of assessment and scoring
criteria against each criterion and sub-criteria are provided in Chapter 4 for
properties of category ‘A and Chapter 5 for properties of category ‘B”.
c. In the end, the assessment report will provide the score card for the property
against each criteria and sub-criteria.
d. A copy of assessment report with URIN and property details shall be uploaded
against respective property. The assessment report will be digitally signed by the
authorized representative of the DCRA. This report will also be visible to the
property manager concerned.
e. The DCRA shall also update the score against each criterion and sub-criteria on
rating platform to generate the rating certificate.
viii. Award of Rating:
a. After the rating score is updated in the rating portal, the DCRA shall generate a
rating certificate and sign it digitally.
b. The Property Manager will be able to download the rating certificate through
their registered account on the rating portal against respective property till its
validity.
Once the rating certificate is issued by DCRA, it will be available for the public to
view or verify the rating certificates either through unique certificate number or
24QR code available on the certificate or other search and filter criteria as may be
provided on the rating platform.
Figure 3.1: High Level Rating Workflow
254. Assessment Methodology for Category ‘A’ Properties
The regulation 24 under Section – VII “Rating criteria and process for evaluation of digital
connectivity and award of ratings” of the Regulation provides criteria, weightage and high-level
sub-criteria against each main criterion for category ‘A’ properties as indicated in column [a],
[b] and [c] respectively in Table 4.1. To enable uniform and objective assessment against each
sub-criteria, the sub-criteria weightage shall be as provided in column [d]. The sub-criteria
weightage has been arrived factoring their relative importance for assessment of digital
connectivity and associated infrastructure.
Sub
S. No.
Criteria Criteria Weightage Sub-Criteria Criteria
(as per
No. [a] [b] [c] Weightage
regulation)
[d]
Compliance to
applicable 4.1.1 Approved
2.5
Model DCI design
Building Bye
Laws (MBBL)
4.1 1 5
and National 4.1.2 DCI
Building Code implementation
2.5
(NBC) for as per approved
digital DCI design
connectivity
4.2.1 Provision for
expansion of
Provision in telecom rooms 2
civil and cable
infrastructure, pathways
over and 4.2.2 Provision for
above MBBL expansion of
4.2 2 5
and NBC mobile and 2
requirements, wireline
for ensuring connectivity
robust digital 4.2.3 Ease of
connectivity access of DCI
1
installed for repair
or maintenance
Provision in 4.3.1 Redundancy
4.3 3 5 1
power of power source
26Sub
S. No.
Criteria Criteria Weightage Sub-Criteria Criteria
(as per
No. [a] [b] [c] Weightage
regulation)
[d]
infrastructure, 4.3.2 UPS power
2
over and backup for DCI
above MBBL 4.3.3 Power
or NBC continuity 1
requirements, monitoring
for ensuring 4.3.4 Building
reliable digital Management 1
connectivity System
4.4.1 Availability
of alternate entry
paths for digital 3
connectivity
infrastructure
Digital 4.4.2 Non-
Connectivity flooding measures
4.4 10 3
4 Infrastructure for DCI
Resilience installation
4.4.3
Implementation
of redundancy in 4
power source and
DCI paths
4.5.1 Availability
of the latest
generation of 4
Future
mobile
Readiness of
connectivity
4.5 5 Digital 10
4.5.2 Support for
Connectivity 3
future bands
Infrastructure
4.5.3
Upgradability of 3
wireline DCI
Provision of 4.6.1 Backhaul
Wired fiber connectivity
4.6 6 20 10
Connectivity (service provider
infrastructure to property)
27Sub
S. No.
Criteria Criteria Weightage Sub-Criteria Criteria
(as per
No. [a] [b] [c] Weightage
regulation)
[d]
4.6.2 Fiber
connectivity till 5
user premises
4.6.3 Fiber
connectivity in
each room or 5
office or
commercial space
4.7.1 Number of
wireline Internet
Service
providers having
7.5
integration with
Digital
Connectivity
Availability of
Infrastructure
4.7 7 Service 15
4.7.2 Number of
Providers
Mobile Service
providers having
coverage or
7.5
integration with
Digital
Connectivity
Infrastructure
4.8.1 Mobile
network coverage
and performance
5
in public areas of
property
Service
4.8 8 25
Performance 4.8.2 Secure
public Wi-Fi
network coverage
5
and performance
in public areas of
property
28Sub
S. No.
Criteria Criteria Weightage Sub-Criteria Criteria
(as per
No. [a] [b] [c] Weightage
regulation)
[d]
4.8.3 Mobile
network coverage
and performance 5
in non-public
areas
4.8.4 Secure
public Wi-Fi
network coverage
5
and performance
in non-public
areas
4.8.5 Average
download speed of
different wireline
5
network(s) in
respective highest
speed plan
4.9.1 User
feedback on
User
4.9 9 5 digital 5
Experience
connectivity
experience
Table 4.1: Weightage for different sub-criteria for category ‘A’ properties
The Digital Connectivity Rating Agency (DCRA) shall assess the digital connectivity and
associated infrastructure as per provisions of the Regulations. The detailed assessment
methodology against each sub-criterion is provided in the following sections. The DCRA shall
scrupulously follow the assessment methodology and collect the artifacts, evidence or test
results as prescribed against respective sub-criteria under each main criterion. The required
supporting documents shall be preserved by the DCRA or uploaded to the rating platform as
per the requirement of the regulations, guidelines or rating manual issued or amended from
time to time.
4.1. Compliance to Applicable Model Building Bye Laws (MBBL) and National
Building Code (NBC) for Digital Connectivity
(Weightage: 5)
29This criterion evaluates whether a property adheres to the relevant provisions of Model
Building Bye-Laws (MBBL) and the National Building Code (NBC) of India in terms of digital
connectivity infrastructure. Compliance with these provisions ensures that properties are
designed and constructed with structured telecom infrastructure, safety standards, and
future-readiness for advanced digital services.
4.1.1. Sub-Criteria: Approved Digital Connectivity Infrastructure (DCI) design
(Weightage – 2.5)
i. Objective: The primary goal of this sub-criterion is to evaluate whether the digital
connectivity infrastructure (DCI) for a property has been planned and approved in
compliance with the applicable Model Building Bye-Laws (MBBL) and National
Building Code (NBC) regulations. Ensuring adherence to these standards is crucial
for:
a. Establishing a strong foundation for seamless digital connectivity.
b. Future-proofing readiness of the property by integrating provisions for advanced
communication technologies.
c. Enhancing digital accessibility and reliability for residents, businesses, and service
providers.
ii. Assessment Methodology
The assessment of the approved DCI design will be conducted based on document
verification, compliance checks, and certification validation. The key evaluation steps
are:
a. Availability of Approved DCI or ICT Infrastructure Design Documents:
1. Confirm whether the property manager has obtained formal approval for the DCI
blueprint.
2. Evaluate that the design considers all necessary elements of DCI as per applicable
bye-laws or NBC.
b. Supporting documents:
1. The architectural drawings for digital connectivity or ICT infrastructure
2. The documents should be duly stamped and certified by the competent
authority.
c. Document Review:
1. Verify whether the submitted design aligns with the relevant sections of MBBL
and NBC.
302. Evaluate if the design accommodates evolving digital connectivity needs, such
as provisions for horizontal and vertical pathways, entry points, telecom rooms,
HVAC (Heat ventilation air conditioning) in telecom room etc. as per NBC.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Deviation
Record maintenance
from Type of
S. requirement
Item description MBBL or deviations
No. (Upload/ DCRA
NBC (if any)
level)
(Yes/ No)
Approved DCI design
1. documents by Record and Upload
competent authority
Design drawings
2. certified by competent Record
authority
Design compliance
3. with MBBL and NBC Record
standards
Table 4.2: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as follows:
S. No. Weightage Compliance Requirement
1. 2.5 On compliance to MBBL and NBC
If there is minor deviation in design from MBBL or
NBC. Minor deviations shall be those deviations
2. 2
which do not impact future readiness and
provision of digital connectivity
If there is any major deviation in design from
MBBL or NBC. Major deviation shall be those
3. 0.5 deviations in the design which are likely to impact
future readiness and provisioning of digital
connectivity
Table 4.3: Scoring criteria
31Note:
(i) In case MBBL is not notified by the concerned State/ UT, the provisions of MBBL
issued by Ministry of Housing and Urban Affairs (MoHUA) shall apply for assessment
against this criterion.
(ii) The DCRA shall record the explicit deviations, if any, in its assessment report.
4.1.2. Sub-Criteria: DCI implementation as per approved DCI design
(Weightage – 2.5)
i. Objective: The purpose of this assessment is to ensure that the Digital Connectivity
Infrastructure (DCI) at the property site has been implemented in strict accordance
with the approved DCI design. This verification is carried out in compliance with the
Model Building Bye-Laws (MBBL) and National Building Code (NBC) requirements
to ensure standardization, quality, and maintainability of digital infrastructure
deployment.
ii. Assessment Methodology
The assessment process is divided into three key components: Physical Inspection,
Supporting Documents, and Documentation Review to ensure a thorough
assessment.
a. Physical Inspection:
1. During physical verification, the DCRA shall verify the availability of DCI as
per the approved design under sub-criteria 4.1.1.
2. The compliance and deviations, if any, shall be specifically recorded with
supporting evidence.
b. Supporting Documents:
1. Photographs of installed key DCI infrastructure.
2. Site inspection reports for DCI with design vs implementation comparisons.
3. Testing and Commissioning certificates for DCI as applicable.
c. Documentation Review:
1. Verify the as-build documents and confirm it is as per the approved design.
2. Validate the veracity of as-build DCI implementation with testing and
commissioning certificates for different DCI components.
3. Record observations in the onsite visit report.
32iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Deviation Record
from Type of maintenance
S.
Item description MBBL or deviations requirement
No.
NBC (if any) (Upload/ DCRA
(Yes/ No) level)
As-build DCI is as per
1. Record and upload
approved design
2. Photographs of DCI Record and upload
Site inspection reports for
3. DCI with design Record
comparisons
Testing and
4. Commissioning certificates Record
for DCI as applicable
Table 4.4: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S.
Weightage Compliance Requirement
No.
On compliance with the implementation of DCI or ICT
1. 2.5
infrastructure
If there is minor deviation in implementation of DCI or ICT
infrastructure. Minor deviations shall be those deviations
2. 2
which do not impact future readiness and provision of
digital connectivity.
If there is any major deviation in implementation of DCI or
ICT infrastructure. Major deviation shall be those deviations
3. 0.5
in the design which are likely to impact future readiness and
provisioning of digital connectivity.
Table 4.5: Scoring criteria
4.2. Provision in Civil Infrastructure, over and above MBBL and NBC
requirements, for Ensuring Robust Digital Connectivity
(Weightage: 5)
33This criterion evaluates the extent to which a property goes beyond the mandatory
requirements set by the Model Building Bye-Laws (MBBL) and National Building Code
(NBC) to enhance its digital connectivity infrastructure.
4.2.1. Sub-Criteria: Provision for expansion of telecom rooms and cable
pathways
(Weightage - 2)
i. Objective: To assess the civil infrastructure provisions, over and above MBBL or
NBC requirements, for supporting DCI maintenance and future upgradation. Such
provisions may include the capacity for expanding telecom rooms, cable pathways,
ducts etc. to support increasing telecom and digital infrastructure needs over time.
ii. Assessment Methodology
a. Site Inspection: The Digital Connectivity Rating Agency (DCRA) will
conduct physical inspections to assess:
1. The availability and scalability of such civil infrastructure beyond the
requirement of NBC.
2. Upgradability and maintainability of DCI to support future digital
infrastructure needs. Here maintainability shall mean the ease of installation,
repair and replacement of digital connectivity infrastructure by the property
manager or the service provider, as applicable.
b. Supporting documents: The DCRA will review building layout plans to
verify:
1. The allocation of space for telecom rooms, ducts, and cable pathways.
2. Whether these provisions exceed the standard requirements of NBC or MBBL.
c. Documentation Review:
1. Validate the building layout plans and mark the specific civil infrastructure
considered as being provisioned beyond requirements of NBC or MBBL.
2. Prepare or review the assessment report (if already available with property
manager) on upgradability and maintainability of the civil infrastructure to
support future digital infrastructure needs.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
34Record maintenance
S. Compliance requirement
Item description
No. (Yes/ No) (Upload/ DCRA
level)
Building layout plans for DCI
or ICT infrastructure duly
1. Record and upload
marked and signed by DCRA
and property manager
Expansion feasibility reports
2. – DCI or ICT infrastructure Record
pathways and telecom rooms
Table 4.6: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S.
Weightage Compliance Requirement
No.
If key civil infrastructure like telecom rooms, ducts for
alternate telecom cable entry points, horizontal and
1. 2 vertical pathways etc. is upgradable and maintainable to
support future digital infrastructure needs of fixed and
wireless service providers
If there are minor bottlenecks in above referred civil
2. 1.5 infrastructure. Minor bottlenecks shall be those which do
not impact future upgradability of digital connectivity.
If there is any major bottleneck in future upgradability of
3. 0.5
telecom infrastructure.
Table 4.7: Scoring criteria
4.2.2. Sub-Criteria: Provision for expansion of mobile and wireline
connectivity
(Weightage – 2)
i. Objective: To assess the availability of civil infrastructure like DCI space,
pathways, and provisions to allow for the expansion of both mobile (e.g., 5G/6G)
and wireline connectivity (e.g., fiber-optic cables, Television, camera etc.) inside
the property as technology evolves.
35ii. Assessment Methodology
a. Physical Verification of Expansion Conduits:
1. Inspect the telecom room, ducts, risers, and pathways to assess if sufficient
space is available for future mobile and wireline deployments.
2. Inspect the space earmarked for installation of mobile base station(s),
distributed antenna system, Wi-Fi infrastructure, Direct to Home (DTH)
system etc. to extend coverage inside the property including lifts and
basements.
b. Technology Readiness: Evaluate whether the current civil infrastructure
design supports emerging technologies such as 5G, Internet of Things (IoT,
Machine to Machine Communication (M2M) and high-capacity fiber
networks.
c. Supporting Documents:
1. Layout diagrams for existing civil infrastructure for DCI.
2. Layout indicating provisions for future expansion.
d. Documentation Review: Verify the updated network diagrams and future
expansion plans during the physical verification and site inspection.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record maintenance
S. Compliance
Item description requirement (Upload/
No. (Yes/ No)
DCRA level)
1. Updated network diagrams Record
2. Future expansion plans Record
Table 4.8: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
36S.
Weightage Compliance Requirement
No.
If civil infrastructure or space provision and pathways are
available and space is earmarked to support installation of
1. 2 Mobile base station(s), Distributed Antenna System (DAS),
Wi-Fi, Wireline infrastructure and Direct to Home (DTH)
system etc.
If space provision and pathways exist for at least Mobile base
2. 1.5
station, DAS and Wireline infrastructure
If space provision and pathways exist for at least Wi-Fi or
3. 1
Wireline infrastructure
Table 4.9: Scoring criteria
4.2.3. Sub-Criteria: Ease of access of DCI installed for repair or maintenance
(Weightage – 1)
i. Objective: Properly planned access areas for DCI are essential to ensure ease of
maintenance and repair of digital connectivity infrastructure. This reduces
downtime and service interruptions. These sub-criteria intend to evaluate the ease
of maintenance of DCI which is supported by the provisioned civil infrastructure.
The equipment, cables, pathways, ducts should be easily accessible for smooth repair
and maintenance of DCI by respective service providers.
ii. Assessment Methodology:
a. Physical Accessibility: Conduct on-site assessments to check the physical
accessibility of pathways, telecom rooms, cable ducts and equipment points.
b. Labeling and Marking Verification: Verify all DCI equipment,
pathways, cable ducts etc. are clearly labeled and marked.
c. Supporting documents
1. Site photos showing maintenance pathways.
2. As-build documentation.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
37Record maintenance
Compliance
S. No. Item description requirement (Upload/
(Yes/ No)
DCRA level)
Site photos showing
1. maintenance Record
pathways
Maintenance
2. Record
checklists
Table 4.10: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
If physical accessibility of pathways, telecom
1. 0.5 rooms, cable ducts and equipment is available for
DCI.
If labelling of pathways, telecom rooms, cable ducts
2. 0.5
and equipment is available for DCI.
Table 4.11: Scoring criteria
4.3. Provision in Power Infrastructure, over and above MBBL or NBC
requirements, for Ensuring Reliable Digital Connectivity
(Weightage - 5)
This criterion evaluates additional provisions in power infrastructure that go beyond the
Model Building Bye-Laws (MBBL) and National Building Code (NBC) to ensure
uninterrupted and reliable power supply for digital connectivity.
4.3.1. Sub-Criteria: Redundancy of power source
(Weightage - 1)
i. Objective: The redundant power sources are essential for reliable operation of
digital connectivity. Under this sub-criterion, the availability of redundancy in
power sources is assessed to ensure that DCI remain operational even during power
failures. This redundancy may include backup generators or alternative power
systems.
ii. Assessment Methodology:
a. Verification of actual peak load and available capacity of redundant
power source:
381. Verify the availability of redundant power source for DCI.
2. Verify whether all key DCI and systems are on redundant power source like
alternate feeder or separate power generator.
b. Power Source Switching Tests: Check the functionality of the automatic
switchover mechanism between primary and backup power sources on a sample
basis.
c. Supporting documents:
1. Power layout diagrams.
2. DCI load switchover test report.
d. Documentation Review: Verify the power layout diagrams, load test reports
submitted by the property manager.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record maintenance
S. Compliance
Item description requirement (Upload/
No. (Yes/ No)
DCRA level)
1. Power layout diagrams Record
Load switchover testing
2. Record
reports
Table 4.12: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
If all digital connectivity services affecting load is
1. 1
supported/ fed by redundant power source
Table 4.13: Scoring criteria
4.3.2. Sub-Criteria: UPS power backup for DCI
(Weightage – 2)
i. Objective: The continuity of power supply is essential for uninterrupted digital
connectivity and Uninterrupted Power Supply (UPS) systems play an important
role in service availability for any telecom or information and communication
technology system. This sub-criterion will assess the availability and robustness of
39power backup system in case of failure of input sources i.e. commercial power and
generator supply.
ii. Assessment Methodology:
a. UPS backup verification for DCI:
1. Check from the line diagram whether all DCI systems are provided with UPS
backup.
2. Verify the DCI system rated load and correspond UPS power capacity
provided for DCI from commissioning reports or other authentic documents
to calculate the provisioned UPS backup time.
3. Check the availability of UPS system redundancy by way of load sharing
among multiple UPS if applicable.
4. Sample test the UPS system’s ability to provide uninterrupted power to the
DCI by simulating input power failure.
b. Supporting documents:
1. Electrical system line diagram for key DCI elements including redundant
input sources and UPS system(s).
2. Test reports of UPS power backup time or other supporting document(s)
with full DCI load and other load if any.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record
Complia
maintenance
nce
S. No. Item description requirement
(Yes/
(Upload/ DCRA
No)
level)
Electrical system line diagram
1. including redundant input Record
sources and UPS system(s)
Whether all key DCI systems
2. affecting service availability are Record
on UPS?
Whether UPS system has
3. Record
redundancy?
UPS switch over successfully
4. Record
tested during sample testing?
40Record
Complia
maintenance
nce
S. No. Item description requirement
(Yes/
(Upload/ DCRA
No)
level)
Whether duration of UPS
5. backup matches with available Record
test reports with full DCI load?
Table 4.14: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
UPS power backup for important DCI components > 3
1. 2
Hrs.
UPS power backup for important DCI components is
2. 1
between 1-3 Hrs.
Table 4.15: Scoring criteria
4.3.3. Sub-Criteria: Power continuity monitoring
(Weightage – 1)
i. Objective: The power supply monitoring system plays an important role in ensuring
the power supply continuity to DCI. If the health of power systems like generator or
UPS or switch gear systems is not monitored on a continuous basis, it may result in
major interruption when input commercial power supply fails. Therefore, this sub-
criterion provides special emphasis on the implementation of monitoring system in
the property for power services.
ii. Assessment Methodology:
a. Verification of Monitoring Dashboards: Verify availability of dashboards
or interfaces showing real-time power status, health status of UPS, generator(s),
alerts, and reports/ alerts in case of power failures.
b. Validation of Automated Alerts: Test alert mechanisms for their ability to
notify maintenance team of power anomalies in real time.
c. Supporting documents: Monitoring system screenshots with alerts generated
during testing.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
41summary in the following format:
Record maintenance
S. Compliance
Item description requirement (Upload/
No. (Yes/ No)
DCRA level)
Monitoring system
1. Record and Upload
high level diagram
Capture monitoring
2. system dashboard Record and Upload
screenshot
Monitoring system
3. Record and Upload
diagram
Table 4.16: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
The dashboard covers end-to-end health status
1. 1
monitoring of all power systems
The dashboard covers end-to-end health status
2. 0.5 monitoring of important power systems which may
affect DCI availability
Table 4.17: Scoring criteria
4.3.4. Sub-Criteria: Building Management System
(Weightage – 1)
i. Objective: While power monitoring system manages power related installations,
building management system (BMS) encompasses monitoring of major building
services like fire alarms, access control, Heating, Ventilation Air conditioning
(HVAC), power systems etc. These facilities may affect the performance and
availability of DCI and digital connectivity services. Thus, availability of BMS in the
property enhances the DCI service availability and continuity. Therefore, this sub-
criterion has been incorporated as a part of assessment for an enabling system for
digital connectivity services.
ii. Assessment Methodology
42a. Real-Time Data Integration Tests: Verify that the DCI power, fire alarms
and HVAC management system is integrated with the BMS to provide centralized
control and monitoring for DCI systems.
b. BMS communication and notification validation: Validate that the BMS
receives accurate input data from related sensors or actuators and disseminates
to the operations team in configured timelines.
c. Supporting documents:
1. BMS system high level diagram for DCI system areas of the property.
d. Documentation Review:
1. Verify the BMS screenshots against system diagrams.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record maintenance
S. Compliance requirement
Item description
No. (Yes/ No) (Upload/ DCRA
level)
BMS system
1. Record
architecture diagrams
Test report on DCI power
systems, fire alarms and
2. Record
HVAC integration with
BMS
Sample test report on
detection and notification
3. of main power supply Record
failure and takeover by
generator/UPS for DCI
Table 4.18: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
43S. No. Weightage Compliance Requirement
On availability of BMS integration covering
1. 1 power, fire alarm and HVAC for telecom
room(s) in the property
On availability of BMS integration covering at
2. 0.5 least two out of, power, fire alarm and HVAC
for telecom room(s) in the property
Table 4.19: Scoring criteria
4.4. Digital Connectivity Infrastructure Resilience
(Weightage - 10)
Digital connectivity infrastructure (DCI) resilience is a critical factor in ensuring
uninterrupted and high-quality digital connectivity for properties. Resilience refers to the
ability of the infrastructure to withstand disruptions, minimize downtime, and provide
redundancy in case of failures or network congestion.
4.4.1. Sub-Criteria: Availability of alternate entry paths for digital connectivity
infrastructure
(Weightage – 3)
i. Objective: To assess the availability of alternate external entry paths in the
property. The alternate entry paths enable the service providers to extend digital
connectivity with route diversity which reduces the service disruptions in case of
fault in one segment of the network ring including any damage within the property.
The availability of route diversity up to the telecom rooms is an ideal scenario.
ii. Assessment Methodology:
a. Physical verification as per design documents:
1. Examine on-site layouts for ducts from the entry points and cable pathways
to confirm the availability of alternate entry paths for DCI in the property.
2. Sufficient capacity for multiple service providers.
b. Supporting documents: Ducts and pathway layout diagrams to verify the
availability on site.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
44Record
maintenance
S. Compliance
Item description requirement
No. (Yes/ No)
(Upload/ DCRA
level)
Ducts layout diagrams from different
1. Record
external entry points for fiber/ DCI
Pathway layout diagrams from ducts
2. Record
to telecom room(s) for fiber/ DCI
Table 4.20: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
Availability of alternate duct from property entry point
1. 3
and cable pathway routes till telecom room(s)
Availability of alternate duct from property entry point
2. 2
till telecom room
Availability of alternate cable pathway routes from
3. 1
common location in property till telecom room(s)
Table 4.21: Scoring criteria
4.4.2. Sub-Criteria: Non-flooding measures for DCI installation
(Weightage – 3)
i. Objective: Flooding can cause significant damage to digital connectivity
infrastructure and disruption in digital connectivity. Measures like raised
installations, waterproof enclosures, and drainage systems may prevent flooding of
key DCI elements. This sub-criterion intends to the implementation of non-flooding
measures in the property to protect the DCI.
ii. Assessment Methodology:
a. Site Inspection:
1. Check with the site layout and actual location of telecom rooms if they are
located on higher floors, away from potential flooding zones like basements
or ground floors.
2. Verify that power equipment like generator set, UPS, switch over panels are
installed on raised platforms or locations which are less susceptible to
flooding.
453. Verify that no water drain system is connected to the DCI rooms which can
cause backflow.
b. Drainage System Review: Check the availability of drainage systems with
functional checks to prevent backflow of floodwaters.
c. Supporting documents:
1. Design and layout documentation to review infrastructure layouts to verify
that flood prevention measures align with best practices.
2. Sample photographic evidence for key DCI system as proof of
implementation.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record
maintenance
S. Compliance
Item description requirement
No. (Yes/ No)
(Upload/ DCRA
level)
Whether DCI/telecom room(s)
1. are above ground floor as per Record
design and implementation?
Whether key power systems like
UPS/ Generators for DCI are
2. installed on ground or higher Record
floor with non-flooding
consideration?
Whether drainage system is
3. implemented as per design Record
layout?
Table 4.22: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
Telecom/DCI room(s) and UPS are above ground floor
1. 3 and generators/ switching panels are installed with non-
flooding considerations
46S. No. Weightage Compliance Requirement
Only DCI is implemented above ground floor and backup
2. 2 power system (UPS) is implemented with non-flooding
measure
If DCI and generator system is implemented with non-
3. 1
flooding consideration
Table 4.23: Scoring criteria
4.4.3. Sub-Criteria: Implementation of redundancy in power source and DCI
paths
(Weightage – 4)
i. Objective: The redundant pathways for power and fiber cables inside the property
provide path diversity in extending digital connectivity within and across the floor
or building blocks. Redundancy should be applied to both the power supply and the
connectivity pathways for ensuring that the DCI through other path can take over
without impacting digital connectivity.
ii. Assessment Methodology:
a. Redundancy Verification:
1. Review the DCI for the presence of at least two independent power sources
(e.g., main power grid and backup generators or UPS).
2. Examine the availability of path diversity for fiber or other cables across the
building blocks, basements and towers from digital connectivity
infrastructure room(s).
3. Verify that digital connectivity till key aggregation points is supported by a
minimum of two physically separated paths.
b. Supporting documents:
1. Power and cable layout for DCI indicating path redundancy.
2. Sample test reports demonstrate that actual redundancy performance has
been tested during commissioning.
c. Documentation Review:
1. Verify power and cable layout diagram for DCI indicating path redundancy
with actual implementation.
2. Validate test reports to confirm that redundancy mechanisms function as
intended.
47iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record
maintenance
S. Compliance
Item description requirement
No. (Yes/No)
(Upload/ DCRA
level)
Whether DCI is supported
1. with redundant power Record
sources (Generator/ UPS)?
Whether power system
network layout for DCI is
2. Record
implemented with path
diversity?
Whether sample test reports
3. demonstrate testing of Record
redundancy?
Whether path diversity for
fiber and other cables (DTH/
ethernet as applicable) across
the building blocks,
4. Record
basements and towers from
digital connectivity
infrastructure room(s) is
implemented?
Table 4.24: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
If redundant paths are implemented for power system
1. 4
to DCI and fiber path in the property
If either the power system to DCI or the fiber path
2. 2
incorporate path redundancy
Table 4.25: Scoring criteria
484.5. Future Readiness of Digital Connectivity Infrastructure
(Weightage - 10)
Future readiness in digital connectivity infrastructure ensures that properties are equipped
to support next-generation telecom technologies, evolving connectivity needs and increasing
data demands. Future-ready property may be considered to have been designed to adapt,
scale, and integrate upcoming innovations in digital connectivity, enabling seamless
adoption of emerging technologies like 5G, advanced Wi-Fi and smart building solutions.
4.5.1. Sub-Criteria: Availability of the latest generation of mobile connectivity
(Weightage – 4)
i. Objective: The infrastructure should be equipped to support the latest generation
of mobile connectivity, such as 4G/5G and future network standards, to ensure high-
speed, low-latency, and reliable communication. The availability of advanced mobile
infrastructure significantly impacts digital connectivity performance and user
experience. This sub-criterion focuses on assessing whether a property has the
necessary infrastructure to support current and next-generation mobile networks
and is future-ready for upcoming technologies.
ii. Assessment Methodology:
a. Inspection of latest technology installed Infrastructure:
1. Physical Verification: Inspect the property’s mobile network
infrastructure, providing coverage to the property including distributed
antenna systems (DAS), and fiber backhaul connectivity.
2. Technology Support: Evaluate if the installed infrastructure is sufficient
to provide coverage in the different areas of the property.
b. Technical Validation:
1. Cross-check compatibility with current frequency bands with different
service providers for latest/current technology.
c. Supporting documents:
1. List of the latest generation mobile connectivity equipment’s installed in the
property.
2. Photographs of installed latest generation mobile connectivity equipment.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
49Record maintenance
S. Compliance
Item description requirement (Upload/
No. (Yes/ No)
DCRA level)
Whether the
equipment installed
1. supports the latest Record
generation of mobile
connectivity?
Photographs of
installed latest
2. generation mobile Record
connectivity
equipment
Table 4.26: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S.
Weightage Compliance Requirement
No.
If equipment like DAS, RRU, Base Station, etc.
1. 4 supporting 5G technology are installed in the property
for mobile connectivity
If equipment like DAS, RRU, Base Station, etc.
2. 2 supporting 4G technology are installed in the property
for mobile connectivity
Table 4.27: Scoring criteria
4.5.2. Sub-Criteria: Support for future bands
(Weightage - 3)
i. Objective: To ensure long-term relevance and adaptability, digital connectivity
infrastructure must be designed to support the integration of future wireless
communication bands and evolving wired and mobile technologies. The rapid
evolution of telecommunications standards, frequency bands, and network
technologies necessitates a future-proof approach to infrastructure planning. This
enables seamless upgrades, minimizes costly retrofitting, and ensures properties
remain technologically competitive for years to come.
ii. Assessment Methodology
a. Validate the support or upgradability of installed Digital Connectivity
Infrastructure (DCI) for future bands for latest technology.
50b. Verify RF infrastructure installed like radio units, baseband units, duplexers,
combiners and transmitters, as applicable, are capable for supporting upcoming
technologies and frequency bands.
c. Supporting documents:
1. Bill of Material (BoM) installed at the property and datasheets for relevant
equipment.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record maintenance
S. Compliance requirement
Item description
No. (Yes/ No) (Upload/ DCRA
level)
Bill of Material (BoM)
installed at building along
1. Record
with datasheets for
relevant equipment
Whether DCI supports
future bands for mobile or
2. Wi-Fi network as Record
applicable as per
datasheets?
Table 4.28: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
If installed infrastructure supports future bands for
1. 3 4G and 5G technology and/or Wi-Fi network as per
the extant frequency roadmap of DoT.
If installed infrastructure supports future bands for
2. 2 4G technology and/or Wi-Fi network as per the
extant frequency roadmap of DoT.
If installed infrastructure supports future bands for
3. 1 4G technology or Wi-Fi network as per the extant
frequency roadmap of DoT.
Table 4.29: Scoring criteria
514.5.3. Sub-Criteria: Upgradability of wireline DCI
(Weightage – 3)
i. Objective: Wireline digital connectivity infrastructure (DCI), such as fiber-optic
networks, plays a crucial role in ensuring high-speed internet access and seamless
communication. As technology evolves, infrastructure must be designed to
accommodate future upgrades, such as higher bandwidth capacities, new
transmission standards, and enhanced network architectures. This sub-criterion
evaluates whether the existing fiber-optic network can be scaled or upgraded
without requiring extensive rework.
ii. Assessment Methodology:
a. Existing bandwidth verification:
1. Assess the current fiber-optic network’s bandwidth capabilities to determine
if it supports high-speed data transfer (e.g., 1 Gbps, 10 Gbps, or higher).
2. Evaluate the type of fiber used and whether it can support technologies such
as Dense Wavelength Division Multiplexing (DWDM) or Passive Optical
Networks (PON).
b. Scalability review:
1. Inspect the physical infrastructure, including cable pathways, ducts, and
fiber termination points, to verify if additional fiber cables can be added in
the future without major structural modifications.
2. Check the fiber distribution frames to assess whether they allow easy
upgrades or expansions.
3. Determine whether there is spare capacity in existing ducts and conduits to
accommodate additional fiber strands if needed.
c. Supporting documents:
1. Documents to demonstrate upgradability of wireline DCI.
2. Photographic evidence of installed wireline DCI to document their capacity
for future expansion.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
52Record
maintenance
S. Compliance
Item description requirement
No. (Yes/ No)
(Upload/ DCRA
level)
Upgradability of existing
wireline DCI equipment’s
1. (switches/ routers/ splitters/ Record
PON etc.) and relevant
cables
Whether the bandwidth
supported through optical
2. Record
fiber with speed 1 Gbps or
higher?
Table 4.30: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S.
Weightage Compliance Requirement
No.
If existing wireline infrastructure is on fiber and support
1. 3
minimum 1 Gbps to end users
If existing wireline infrastructure is on fiber and support
2. 2
minimum 500 Mbps to end users
If existing wireline infrastructure is on fiber and support
3. 1
minimum 100 Mbps to end users
Table 4.31: Scoring criteria
4.6. Provision of Wired Connectivity Infrastructure
(Weightage - 20)
This criterion evaluates the availability, quality, and scalability of the wired connectivity
infrastructure within a property.
A robust wired network ensures high-speed, reliable, and low-latency digital connectivity,
supporting various applications such as business operations, smart building technologies
and residential broadband needs as per property use.
534.6.1. Sub-Criteria: Backhaul fiber connectivity (service provider to property)
(Weightage – 10)
i. Objective: A high-capacity fiber optic backhaul connection is essential to ensure
high-speed and uninterrupted digital connectivity for users within the property. The
presence of a dedicated fiber connection from the service provider to the property
enhances network performance, reduces latency, and supports high-bandwidth
applications such as video conferencing, cloud computing, and smart building
management systems.
ii. Assessment Methodology:
a. Fiber availability check:
1. Conduct a physical verification of the fiber optic backhaul infrastructure
connected to the service provider’s network.
2. Check redundancy measures, such as dual entry fiber paths, in place for
uninterrupted fiber connectivity in case of failure.
b. Bandwidth verification:
1. Measure and validate the actual peak and average bandwidth available in the
property from all service providers on aggregate level.
2. In the case of business, office or commercial property, check availability of
leased line support on fiber.
c. Supporting documents:
Fiber cable details form service providers to the property and supporting
documents regarding available bandwidth from each service provider on
fiber.
d. Documentation Review: Validate the Telecom/ Internet service provider
agreements and fiber/ bandwidth testing results.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record maintenance
Compliance
S. No. Item description requirement (Upload/
(Yes/ No)
DCRA level)
1. Fiber testing results Record
54Record maintenance
Compliance
S. No. Item description requirement (Upload/
(Yes/ No)
DCRA level)
Photographs of fiber
2. termination point at Record and Upload
main telecom room
Table 4.32: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Criteria
(No. of wireline service providers
Weightage
having fiber backhaul)
awarded =
10* (No. of wireline service providers
present in the property)
(If number of wireline service providers in property are
1. 10
>=3)
Note: In the case of wireline service providers there are
less than three, the above formula will apply considering
50% weightage (i.e. 5 in place of 10) against this
parameter
Table 4.33: Scoring criteria
4.6.2. Sub-Criteria: Fiber connectivity till user premises
(Weightage – 5)
i. Objective: Sub-criterion assesses whether high-capacity fiber-optic infrastructure
extends up to the end-users within a property. The aim is to ensure that residents,
businesses, and offices benefit from high-speed, reliable internet connectivity. A
fiber-optic connection reaching the user premises guarantees superior bandwidth,
lower latency, and future-proof infrastructure capable of supporting evolving digital
requirements such as 5G backhaul, cloud services, and smart building applications.
The well planned and laid fiber cables from telecom room(s) to the user premises
(flat/ home/ office/ shop etc. as applicable) enables faster provisioning and easy to
maintain.
55ii. Assessment Methodology
a. Physical Inspection: Verify that fiber-optic cabling extends up to each
residential, office, or commercial unit within the property.
b. Supporting documents:
1. Fiber network architecture showing fiber distribution from the telecom/
room or meeting point to each unit.
2. Fiber test reports confirming connectivity to each unit
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record maintenance
S. Compliance
Item description requirement (Upload/
No. (Yes/ No)
DCRA level)
Fiber layout diagrams up
1. Record and Upload
to user premises
Sample fiber test reports
2. confirming connectivity Record and Upload
to each user premise
Table 4.34: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
If fiber connectivity is extended to all user units within
1. 5
the property
If fiber connectivity is extended to a minimum of 50%
2. 3
of user units within the property
If fiber connectivity is extended to a minimum of 30%
3. 1
of user units within the property
Table 4.35: Scoring criteria
4.6.3. Sub-Criteria: Fiber connectivity in each room or office or commercial
space
(Weightage – 5)
i. Objective: The goal of this sub-criterion is to assess whether every individual space
within the property, whether a residential unit, office, or commercial
establishment—has fiber connectivity. This guarantees seamless high-speed internet
56access across the entire property, eliminating connectivity dead zones and ensuring
a uniform digital experience for all occupants.
ii. Assessment Methodology:
a. Visual Inspection: Inspect rooms, offices, or commercial spaces on a sample
basis to confirm the presence of fiber-optic connectivity infrastructure and
termination points in each room/ office.
b. Supporting documents:
1. Network layout diagram for user units showing fiber terminations and
sample test reports for fiber terminations.
2. Site survey reports and photographic evidence.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record maintenance
S. Compliance
Item description requirement (Upload/
No. (Yes/ No)
DCRA level)
Network layout diagram
1. for user units showing Record
fiber terminations
Sample test reports for
2. fiber terminations Record and Upload
testing
Table 4.36: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
If fiber connectivity is extended in each room/ office/
1. 5
commercial space of all user units within the property
If fiber connectivity is extended in each room/ office/
2. 3 commercial space of minimum 50% of user units
within the property
If fiber connectivity is extended in each room/ office/
3. 1 commercial space of minimum 30% of user units
within the property
Table 4.37: Scoring criteria
574.7. Availability of Service Providers
(Weightage - 15)
This criterion evaluates the number and diversity of wireline and mobile service providers
that have integrated their services with the Digital Connectivity Infrastructure (DCI) of a
property. A higher number of available providers ensure better service quality, redundancy
and consumer choice.
4.7.1. Sub-Criteria: Number of wireline Internet Service providers having
integration with Digital Connectivity Infrastructure
(Weightage - 7.5)
i. Objective: The presence of multiple wireline Internet Service Providers (ISPs)
within a property significantly enhances competition, service quality, redundancy,
and network resilience, ensuring reliable and high-speed digital connectivity. A
multi-ISP infrastructure benefits property managers, businesses, and residents by
providing greater flexibility, improved service continuity, and optimized cost
structures.
ii. Assessment Methodology:
a. Verification of ISP Integration: Confirm the number of wireline TSP/ ISPs
integrated with the DCI by inspecting the infrastructure and service availability.
b. Telecom/Internet Service Provider Agreement Review: Verify
agreements with TSP/ISPs and sample integration test reports.
c. Validation: Verify that all integrated TSP/ISPs are operational.
d. Supporting documents:
1. Telecom/ Internet Service Provider (TSP/ ISP) Agreements.
2. Network integration certificates/ test reports.
3. Service subscription status.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record maintenance
Item Compliance
S. No. requirement (Upload/
description (Yes/ No)
DCRA level)
Telecom/
1. Record
Internet Service
58Record maintenance
Item Compliance
S. No. requirement (Upload/
description (Yes/ No)
DCRA level)
Provider (ISP)
Agreements
Network
integration
2. Record
certificates/ test
reports
Service
3. subscription Record
status
Table 4.38: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S.
Weightage Compliance Requirement
No.
If 3 or more internet service providers have integration
1. 7.5
with DCI in the property with active service subscription
If a minimum of 2 internet service providers have
2. 5 integration with DCI in the property with active service
subscription
If at least one internet service provider has integration
3. 2
with DCI in the property with active service subscription
Table 4.39: Scoring criteria
4.7.2. Sub-Criteria: Number of Mobile Service providers having coverage or
integration with Digital Connectivity Infrastructure
(Weightage – 7.5)
i. Objective: The objective of this sub-criterion is to assess the extent to which
multiple mobile service providers (TSPs) are integrated with the property’s digital
connectivity infrastructure (DCI) or have adequate service coverage as per sub-
criteria 8.1. Having multiple mobile service providers ensures users have reliable
network coverage, high-quality service, and reduced congestion, particularly in
high-density areas like commercial properties, residential complexes, and office
spaces.
59ii. Assessment Methodology:
a. Coverage Verification:
1. Confirm the number of Telecom Service Providers (TSPs) providing indoor
coverage for the property.
2. Validate integration of the DCI with In-Building Solutions (IBS)/ Small
Cells/ Wi-Fi offload for enhanced indoor mobile coverage.
b. Supporting documents:
1. Agreements signed with Telecom Service Providers.
2. RF coverage map in the property or walk/ drive test results.
c. Documentation Review: Validate the TSP agreements and network
integration test reports.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record
maintenance
Compliance
S. No. Item description requirement
(Yes/ No)
(Upload/ DCRA
level)
RF coverage map in the
property or walk/ drive
1. Record and Upload
test results
Network performance test
2. results from multiple Record
operators
Agreements signed with
Telecom Service Providers
3. Record
(without commercial
details)
Table 4.40: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
If 3 or more mobile service providers have integration with
1. 7.5 DCI in the property or more 75% coverage in indoor area of
the property
60S. No. Weightage Compliance Requirement
If at least two mobile service providers have integration
2. 5 with DCI in the property or more 75% coverage in indoor
areas
If at least one mobile service provider has integration with
3. 2
DCI in the property or more 75% coverage in indoor areas
Table 4.41: Scoring criteria
4.8. Service Performance
(Weightage: 25)
Service performance is a critical factor in evaluating the digital connectivity of a property.
This criterion assesses service performance parameters to assess digital experience in the
property including lifts and basements. For assessment of mobile service coverage, the
reference minimum signal strength for 2G/4G/5G technology shall be same as prescribed by
TRAI for publishing of coverage map under revised QoS regulation i.e. ‘THE STANDARDS
OF QUALITY OF SERVICE OF ACCESS (WIRELINE AND WIRELESS) AND BROADBAND
(WIRELINE AND WIRELESS) SERVICE REGULATIONS, 2024 (06 of 2024)’.
4.8.1. Sub-Criteria: Mobile network coverage and performance in public areas
of property
(Weightage – 5)
i. Objective: The mobile network performance in public areas (e.g., lobbies,
corridors, lifts, basements) should meet minimum requirements for signal strength
and speed which is essential for superior user experience, safety, and efficient
operations.
ii. Assessment Methodology:
a. Conduct RF testing for mobile coverage in public spaces like lobbies, corridors,
common utilities like gym, banquet hall, garden, parking, lifts, basements and
entrances using industry standard tools.
b. Assess data speed and voice call quality over a day (preferably 10 am to 8pm
with samples uniformly distributed covering peak hours in property) using
test probes for each service provider whose coverage is available on the
property and accounted under criteria 7- Availability of Service Providers’.
Measurements to be carried out shall include peak as well as off-peak hours.
61c. Supporting documents
1. RF coverage map/ test results of public areas.
2. Speed test logs and call quality reports.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record maintenance
S. Compliance
Item description requirement (Upload/
No. (Yes/ No)
DCRA level)
RF coverage map of
1. Record and Upload
public areas
Speed test logs and call
2. Record and Upload
quality reports
Table 4.42: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
If at least 3 service providers have more than 85%
mobile coverage for their latest generation of
1. 5 technology in public areas (including lifts and
basements) with signal strength as prescribed for
network coverage map by TRAI.
If at least two service providers have more than 85%
mobile coverage for their latest generation of
2. 3 technology in public areas (including lifts and
basements) with signal strength as prescribed for
network coverage map by TRAI.
If at least one service provider has more than 85%
mobile coverage for their latest generation of
3. 2 technology in public areas (including lifts and
basements) with signal strength as prescribed for
network coverage map by TRAI.
Table 4.43: Scoring criteria
4.8.2. Sub-Criteria: Secure public Wi-Fi network coverage and performance in
public areas of property
(Weightage – 5)
62i. Objective: Public Wi-Fi in the property may complement the mobile coverage.
However, it should be secure and offer a high level of performance, with fast speeds
and low latency. With secure and seamless public Wi-Fi coverage in the property,
consumers can avail the data and voice service. The assessment shall include
evaluating its Wi-Fi network availability, security measures in place, speed, and
latency required for reliable digital connectivity.
ii. Assessment Methodology
a. Identify all public areas within the property where Wi-Fi services are provided,
such as lobbies, lounges, cafeterias, parking areas, lifts, basements and open
seating spaces.
b. Conduct sample WPA2/ WPA3 compliance checks for security.
c. Conduct coverage, speed and latency tests covering peak hours using industry
standard tools.
iii. Supporting documents
1. Wi-Fi Coverage Maps: Diagrams or heatmaps showcasing Wi-Fi coverage
across the property, highlighting areas with weak or strong signals.
2. Speed Test Results: Logs of speed and latency test results from different
locations and times, demonstrating network reliability.
3. Wi-Fi Security Audit Reports: Reports confirming compliance with
WPA2/WPA3 security standards, network authentication mechanisms, and
encryption configurations.
iv. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record maintenance
S. Compliance
Item description requirement (Upload/
No. (Yes/ No)
DCRA level)
Wi-Fi coverage
1. maps and speed test Record and Upload
results
Wi-Fi security audit
2. Record and Upload
reports
Table 4.44: Compliance checklist
63v. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S.
Weightage Compliance Requirement
No.
If secure Wi-Fi coverage is available in more than 85% of
1. 5 public or common area of the property (including lifts and
basements)
If secure Wi-Fi coverage is available in more than 75% of
2. 3 public or common area of the property (including lifts and
basements)
If secure Wi-Fi coverage is available in more than 65% of
3. 2 public or common area of the property (including lifts
and basements)
Table 4.45: Scoring criteria
4.8.3. Sub-Criteria: Mobile network coverage and performance in non-public
areas
(Weightage – 5)
i. Objective: The mobile network should maintain high performance in private or
restricted areas, such as residential flats, offices, conference rooms, lift, basement,
executive cabins etc. within a property. The objective of this criterion is to assess the
availability of mobile network coverage in private areas of the property.
ii. Assessment Methodology
a. Conduct RF testing for mobile coverage in pre-defined non-public areas using
industry standard tools.
b. Monitor and assess data speed, video quality and voice call quality over a day
using probes. Measurement to be carried out covering peak hours of traffic in the
property.
iii. Supporting documents
1. RF coverage map of areas under test or drive test results
2. Speed test logs, call setup success rate and quality (Mean Opinion Score)
reports for minimum 100 calls.
iv. Compliance check list: The DCRAs shall prepare and maintain the compliance
summary in the following format:
64Record maintenance
S. Item Compliance
requirement (Upload/
No. description (Yes/ No)
DCRA level)
RF coverage map
1. Record and Upload
of areas under test
Speed test logs
and call setup and
2. Record and Upload
call quality
reports
Table 4.46: Compliance checklist
v. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S.
Weightage Compliance Requirement
No.
If at least 3 service providers have more than 80% mobile
coverage for their latest generation of technology in non-
1. 5 public areas (including lifts and basements) with
minimum download speed of 10Mbps for 4G or 100 Mbps
for 5G technology as applicable.
If at least 2 service providers have more than 70% mobile
coverage for their latest generation of technology in non-
2. 3 public areas (including lifts and basements) with average
minimum download speed of 10Mbps for 4G or 100 Mbps
for 5G technology as applicable.
If at least 2 service providers have more than 50% mobile
coverage for their latest generation of technology in non-
3. 2 public areas (including lifts and basements) with average
minimum download speed of 10Mbps for 4G or 100 Mbps
for 5G technology as applicable.
Table 4.47: Scoring criteria
Note: Download speed to be tested through TRAI App.
4.8.4. Sub-Criteria: Secure public Wi-Fi network coverage and performance
in non-public areas
(Weightage – 5)
i. Objective: Public Wi-Fi in the property may complement the mobile coverage.
However, it should be secure and offer a high level of performance, with fast speeds
and low latency. With secure and seamless public Wi-Fi coverage in the property,
65consumers can avail the data and voice service. The goal is to assess Wi-Fi coverage
in non-public areas, such as residential flats, enterprise workspaces, executive
offices, lifts, basements, conference rooms, etc. These areas require reliable, high-
speed, and encrypted Wi-Fi connectivity to support business operations, data
security, and seamless enterprise communication.
ii. Assessment Methodology:
To evaluate compliance with this sub-criterion, the following steps will be
undertaken:
a. Identify all non-public areas within the property where Wi-Fi services are
provided.
b. Conduct sample WPA2/ WPA3 compliance checks for security.
c. Conduct coverage, speed and latency tests covering peak hours using industry
standard tools.
iii. Supporting documents:
a. Wi-Fi Coverage Maps: Diagrams or heatmaps showing Wi-Fi coverage across
the property in non-public areas, highlighting areas with weak or strong signals.
b. Speed Test Results: Logs of speed and latency test results from different
locations and times, demonstrating network reliability.
c. Wi-Fi Security Audit Reports: Reports confirming compliance with WPA2/
WPA3 security standards, network authentication mechanisms, and encryption
configurations.
iv. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record maintenance
S. Compliance
Item description requirement (Upload/
No. (Yes/ No)
DCRA level)
Wi-Fi security
1. Record
certifications
Wi-Fi coverage maps
2. and speed test Record and Upload
results
Table 4.48: Compliance checklist
66v. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S.
Weightage Compliance Requirement
No.
If secure Wi-Fi coverage is available in more than 85% of
non- public areas of the property (including lifts and
1. 5
basements) with minimum download speed of 20 Mbps in
peak hours
If secure Wi-Fi coverage is available in more than 75% of
non-public areas of the property (including lifts and
2. 3
basements) with minimum download speed of 20 Mbps in
peak hours
If secure Wi-Fi coverage is available in more than 65% of
non-public areas of the property (including lifts and
3. 2
basements) with minimum download speed of 20 Mbps in
peak hours
Table 4.49: Scoring criteria
Note: Download speed to be tested through TRAI App.
4.8.5. Sub-Criteria: Average download speed of different wireline network(s)
in respective highest speed plan
(Weightage – 5)
i. Objective: The objective of this sub-criterion is to assess the highest average
download speed supported by different wireline networks or service providers under
their offered plans in the property.
ii. Assessment Methodology:
a. Conduct speed tests using standard tools (TRAI My Speed App). Conduct tests
during peak traffic hour(s) at least at five different user locations.
b. Compare results against advertised speeds under highest plan by respective ISP
in highest tier plans. Compare actual speed test results with these promised
speeds.
c. Supporting documents: Speed test results with timestamps.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
67Record maintenance
S. Item Compliance
requirement (Upload/
No. description (Yes/ No)
DCRA level)
1. Speed test
results with Record and Upload
timestamps
Table 4.50: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S.
Weightage Compliance Requirement
No.
If download speed of any wireline network is more than
1. 5
500 Mbps
If the download speed of any wireline network is more
2. 3
than 250 Mbps
If the download speed of any wireline network is more
3. 2
than 100 Mbps
Table 4.51: Scoring criteria
4.9. User Experience
(Weightage - 5)
User experience assesses user feedback on digital connectivity, including network reliability,
speed, latency, and ease of access. It considers factors like seamless browsing, streaming
quality and minimal disruptions. A positive experience indicates robust connectivity, while
frequent issues highlight areas for improvement.
4.9.1. Sub-Criteria: User feedback on digital connectivity experience
(Weightage – 5)
i. Objective: The objective of this sub-criterion is to collect and analyze user feedback
regarding their experience with mobile, wireline, and Wi-Fi services in a property.
User insights help assess the real-world performance of the digital connectivity
infrastructure, identify gaps in service quality and drive improvements to enhance
the overall connectivity experience.
ii. Assessment Methodology:
a. Conduct structured surveys capturing user satisfaction on voice call quality, voice
call accessibility, voice call retainability, data speed (wireline and wireless),
latency, service uptime and coverage.
68b. The feedback should be collected from a minimum of 10% of the users of the
property if the total users are less than 1000. In case total users are more than
1000, then feedback may be collected from a minimum of 100 users. The users
in survey should be distributed across gender and broad adult age groups.
iii. Supporting documents:
a. User feedback form (please refer to Appendix section for the indicative feedback
form).
iv. Compliance check list: The DCRAs shall prepare and maintain the compliance
summary in the following format.
Record maintenance
S. Compliance requirement
Item description
No. (Yes/ No) (Upload/ DCRA
level)
1. User feedback form Record and Upload
Table 4.52: Compliance checklist
v. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
If 80% of users provide overall positive experience for
1. 5
digital connectivity in the property
If 70% of users provide overall positive experience for
2. 3
digital connectivity in the property
If 50% of users provide overall positive experience
3. 2
for digital connectivity in the property
If 40% of users provide overall positive experience for
4. 1
digital connectivity in the property
Table 4.53: Scoring criteria
Note: In case of new property, where actual end users are yet to use services, the weightage
against ‘user experience’ shall be merged with ‘Service Performance’.
694.10. Summary of Rating Score
After assessment and scoring against each criterion and sub-criteria as per assessment
methodology, the DCRA shall prepare the summary of rating score in following format for
final updating in the rating platform for generating the rating certificate:
Sub Score
Criteria Criteria Weightage Sub-Criteria Criteria awarded
No. [a] [b] [c] Weightage by DCRA
[d]
Compliance to
applicable 4.1.1 Approved DCI
2.5
Model design
Building Bye
Laws (MBBL)
4.1 5
and National 4.1.2 DCI
Building Code implementation as
2.5
(NBC) for per approved DCI
digital design
connectivity
4.2.1 Provision for
Provision in expansion of telecom
2
civil rooms and cable
infrastructure, pathways
over and 4.2.2 Provision for
above MBBL expansion of mobile
4.2 5 2
and NBC and wireline
requirements, connectivity
for ensuring 4.2.3 Ease of access
robust digital of DCI installed for
1
connectivity repair or
maintenance
Provision in 4.3.1 Redundancy of
1
power power source
infrastructure, 4.3.2 UPS power
2
over and backup for DCI
above MBBL 4.3.3 Power
4.3 5
or NBC continuity 1
requirements, monitoring
for ensuring
4.3.4 Building
reliable digital 1
Management System
connectivity
70Sub Score
Criteria Criteria Weightage Sub-Criteria Criteria awarded
No. [a] [b] [c] Weightage by DCRA
[d]
4.4.1 Availability of
alternate entry paths
for digital 3
connectivity
infrastructure
Digital
Connectivity 4.4.2 Non-flooding
4.4 10
Infrastructure measures for DCI 3
Resilience installation
4.4.3.Implementation
of redundancy in
4
power source and
DCI paths
4.5.1 Availability of
the latest generation
4
Future of mobile
Readiness of connectivity
4.5 Digital 10
4.5.2 Support for
3
Connectivity
future bands
Infrastructure
4.5.3 Upgradability of
3
wireline DCI
4.6.1 Backhaul fiber
connectivity (service 10
provider to property)
Provision of 4.6.2 Fiber
Wired connectivity till user 5
4.6 20
Connectivity premises
infrastructure
4.6.3 Fiber
connectivity in each
5
room or office or
commercial space
71Sub Score
Criteria Criteria Weightage Sub-Criteria Criteria awarded
No. [a] [b] [c] Weightage by DCRA
[d]
4.7.1 Number of
wireline Internet
Service
providers having 7.5
integration with
Digital Connectivity
Availability of
Infrastructure
4.7 Service 15
4.7.2 Number of
Providers
Mobile Service
providers having
coverage or 7.5
integration with
Digital Connectivity
Infrastructure
4.8.1 Mobile network
coverage and
performance in 5
public areas of
property
4.8.2 Secure public
Wi-Fi network
coverage and
5
performance in
public areas of
Service
4.8 25 property
Performance
4.8.3 Mobile network
coverage and
5
performance in non-
public areas
4.8.4 Secure public
Wi-Fi network
coverage and 5
performance in non-
public areas
72Sub Score
Criteria Criteria Weightage Sub-Criteria Criteria awarded
No. [a] [b] [c] Weightage by DCRA
[d]
4.8.5 Average
download speed of
different wireline
5
network(s) in
respective highest
speed plan
4.9.1 User feedback
User on digital
4.9 5 5
Experience connectivity
experience
Table 4.54: Summary of Rating Score
735. Assessment Methodology for Category ‘B’ Properties
The regulation 25 under Section – VII “Rating criteria and process for evaluation of digital
connectivity and award of ratings” of the Regulation provides criteria, weightage and high-level
sub-criteria against each main criterion as indicated in column [a], [b] and [c] respectively in
Table 5.1. To enable uniform and objective assessment against each sub-criteria, the sub-
criteria weightage shall be as provided in column [d]. The sub-criteria weightage has been
arrived, factoring their relative importance for assessment of digital connectivity and
associated infrastructure for properties under Category ‘B’.
Sub
Criteria Criteria Weightage Sub-Criteria Criteria
No. [a] [b] [c] Weightage
[d]
Provision in 5.1.1 Redundancy of power source 2
power
infrastructure 5.1.2 UPS power backup for DCI 4
5.1 for ensuring 10
reliable 5.1.3 Power continuity monitoring 2
digital
5.1.4 Building Management
connectivity 2
System
5.2.1 Availability of alternate entry
paths for digital connectivity 3
Digital infrastructure
Connectivity 5.2.2 Non-flooding measures for
5.2 10 3
Infrastructure DCI installation
Resilience 5.2.3 Implementation of
redundancy in power source and 4
DCI paths
Future 5.3.1 Availability of the latest
4
Readiness of generation of mobile connectivity
5.3 Digital 10
5.3.2 Support for future bands 3
Connectivity
Infrastructure 5.3.3 Upgradability of wireline DCI 3
Provision of 5.4.1 Backhaul fibre connectivity
10
Wired (service provider to property)
5.4 20
Connectivity 5.4.2 Fibre connectivity till user
5
infrastructure premises
74Sub
Criteria Criteria Weightage Sub-Criteria Criteria
No. [a] [b] [c] Weightage
[d]
5.4.3 Fibre connectivity in each
5
room or office or commercial space
5.5.1 Number of wireline Internet
Service providers having
7.5
integration with Digital
Availability of
Connectivity Infrastructure
5.5 Service 15
5.5.2 Number of Mobile Service
Providers
providers having coverage or
7.5
integration with Digital
Connectivity Infrastructure
5.6.1 Mobile network coverage and
performance in public areas of 5
property
5.6.2 Secure public Wi-Fi network
coverage and performance in 5
public areas of property
Service 5.6.3 Mobile network coverage and
5.6 25 5
Performance performance in non-public areas
5.6.4 Secure public Wi-Fi network
coverage and performance in non- 5
public areas
5.6.5 Average download speed of
different wireline network(s) in 5
respective highest speed plan
User 5.7.1 User feedback on digital
5.7 10 10
Experience connectivity experience
Table 5.1: Weightage for different sub-criteria for category ‘B’ properties
The Digital Connectivity Rating Agency (DCRA) shall assess the digital connectivity and
associated infrastructure as per provisions of the Regulations. The assessment methodology
against each sub-criterion is provided in the following sections. The DCRA shall scrupulously
follow the assessment methodology and collect the artifacts, evidence or test results as
prescribed against respective sub-criteria under each main criterion. The required supporting
documents shall be preserved by the DCRA or uploaded to the rating platform as per the
requirement of the regulations, guidelines or rating manual issued or amended from time to
time.
755.1. Provision in Power Infrastructure for Ensuring Reliable Digital
Connectivity
(Weightage: 10)
This criterion evaluates provisions in power infrastructure to ensure uninterrupted and
reliable power supply for digital connectivity.
5.1.1. Sub-Criteria: Redundancy of power source
(Weightage: 2)
i. Objective: The redundant power sources are essential for reliable operation of
digital connectivity. Under this sub-criterion, the availability of redundancy in
power sources is assessed to ensure that DCI remain operational even during power
failures. This redundancy may include backup generators or alternative power
systems.
ii. Assessment Methodology:
a. Verification of actual peak load and available capacity of redundant
power source:
1. Verify the availability of redundant power source for DCI.
2. Verify whether all key DCI and systems are on redundant power source like
alternate feeder or separate power generator.
b. Power Source Switching Tests: Check the functionality of the automatic
switchover mechanism between primary and backup power sources on a sample
basis.
c. Supporting documents:
1. Power layout diagrams.
2. DCI load switchover test report.
d. Documentation Review: Verify the power layout diagrams, load test reports
submitted by the property manager.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record maintenance
S. Compliance
Item description requirement (Upload/
No. (Yes/ No)
DCRA level)
1. Power layout diagrams Record
76Record maintenance
S. Compliance
Item description requirement (Upload/
No. (Yes/ No)
DCRA level)
Load switchover testing
2. Record
reports
Table 5.2: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
If all digital connectivity services affecting load is
1. 2
supported/ fed by redundant power source
Table 5.3: Scoring criteria
5.1.2. Sub-Criteria: UPS power backup for DCI
(Weightage – 4)
i. Objective: The continuity of power supply is essential for uninterrupted digital
connectivity and Uninterrupted Power Supply (UPS) systems play an important role
in service availability for any telecom or information and communication technology
system. This sub-criterion will assess the availability and robustness of power
backup system in case of failure of input sources i.e. commercial power and
generator supply.
ii. Assessment Methodology
a. UPS backup verification for DCI:
1. Check from the line diagram whether all DCI systems are provided with UPS
backup.
2. Verify the DCI system rated load and correspond UPS power capacity
provided for DCI from commissioning reports or other authentic documents
to calculate the provisioned UPS backup time.
3. Check the availability of UPS system redundancy by way of load sharing
among multiple UPS if applicable.
4. Sample test the UPS system’s ability to provide uninterrupted power to the
DCI by simulating input power failure.
b. Supporting documents:
1. Electrical system line diagram for key DCI elements including redundant
input sources and UPS system(s).
2. Test reports of UPS power backup time or other supporting document(s) with
full DCI load and other load if any.
77iii. Compliance check list: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record
maintenance
Compliance
S. No. Item description requirement
(Yes/ No)
(Upload/ DCRA
level)
Electrical system line diagram
1. including redundant input Record
sources and UPS system(s)
Whether all key DCI systems
2. affecting service availability are Record
on UPS?
Whether UPS system has
3. Record
redundancy?
UPS switch over successfully
4. Record
tested during sample testing?
Whether duration of UPS
5. backup matches with available Record
test reports with full DCI load?
Table 5.4: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
UPS power backup for important DCI components > 3
1. 4
Hrs.
UPS power backup for important DCI components is
2. 2
between 1-3 Hrs.
Table 5.5: Scoring criteria
5.1.3. Sub-Criteria: Power continuity monitoring
(Weightage – 2)
i. Objective: The power supply monitoring system plays an important role in
ensuring the power supply continuity to DCI. If the health of power systems like
generator or UPS or switch gear systems is not monitored on a continuous basis, it
may result in major interruption when input commercial power supply fails.
78Therefore, this sub-criterion provides special emphasis on the implementation of
monitoring system in the property for power services.
ii. Assessment Methodology
a. Verification of Monitoring Dashboards: Verify availability of dashboards
or interfaces showing real-time power status, health status of UPS, generator(s),
alerts, and reports/alerts in case of power failures.
b. Validation of Automated Alerts: Test alert mechanisms for their ability to
notify maintenance team of power anomalies in real time.
c. Supporting documents: Monitoring system screenshots with alerts generated
during testing.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record maintenance
S. Compliance
Item description requirement (Upload/
No. (Yes/ No)
DCRA level)
Monitoring system
1. Record and Upload
high level diagram
Capture monitoring
2. system dashboard Record and Upload
screenshot
Monitoring system
3. Record and Upload
diagram
Table 5.6: Compliance checklist
iv. Scoring criteria: The DCRA shall award weightage against this sub-criterion as
per the following scoring criteria:
S. No. Weightage Compliance Requirement
The dashboard covers end-to-end health status
1. 2
monitoring of all power systems
The dashboard covers end-to-end health status
2. 1 monitoring of important power systems which may
affect DCI availability
Table 5.7: Scoring criteria
795.1.4. Sub-Criteria: Building Management System
(Weightage – 2)
i. Objective: While power monitoring system manages power related installations,
building management system (BMS) encompasses monitoring of major building
services like fire alarms, access control, Heating, Ventilation Air conditioning
(HVAC), power systems etc. These facilities may affect the performance and
availability of DCI and digital connectivity services. Thus, availability of BMS in the
property enhances the DCI service availability and continuity. Therefore, this sub-
criterion has been incorporated as a part of assessment for an enabling system for
digital connectivity services.
ii. Assessment Methodology:
a. Real-Time Data Integration Tests: Verify that the DCI power, fire alarms
and HVAC management system is integrated with the BMS to provide centralized
control and monitoring for DCI systems.
b. BMS communication and notification validation: Validate that the BMS
receives accurate input data from related sensors or actuators and disseminates
to the operations team in configured timelines.
c. Supporting documents:
1. BMS system high level diagram for DCI system areas of the property.
d. Documentation Review:
1. Verify the BMS screenshots against system diagrams.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record maintenance
0S. Compliance requirement
Item description
No. (Yes/ No) (Upload/ DCRA
level)
BMS system architecture
1. Record
diagrams
80Record maintenance
0S. Compliance requirement
Item description
No. (Yes/ No) (Upload/ DCRA
level)
Test report on DCI power
systems, fire alarms and
2. Record
HVAC integration with
BMS
Sample test report on
detection and notification
3. of main power supply Record
failure and takeover by
generator/ UPS for DCI
Table 5.8: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
On availability of BMS integration covering
1. 2 power, fire alarm and HVAC for telecom
room(s) in the property
On availability of BMS integration covering at
2. 1 least two out of, power, fire alarm and HVAC
for telecom room(s) in the property
Table 5.9: Scoring criteria
5.2. Digital Connectivity Infrastructure Resilience
(Weightage: 10)
Digital connectivity infrastructure (DCI) resilience is a critical factor in ensuring
uninterrupted and high-quality digital connectivity for properties. Resilience refers to the
ability of the infrastructure to withstand disruptions, minimize downtime, and provide
redundancy in case of failures or network congestion.
5.2.1. Sub-Criteria: Availability of alternate entry paths for digital connectivity
infrastructure
(Weightage – 3)
i. Objective: To assess the availability of alternate external entry paths in the
property. The alternate entry paths enable the service providers to extend digital
connectivity with route diversity which reduces the service disruptions in case of
81fault in one segment of the network ring including any damage within the property.
The availability of route diversity up to the telecom rooms is an ideal scenario.
ii. Assessment Methodology:
a. Physical verification as per design documents:
1. Examine on-site layouts for ducts from the entry points and cable pathways
to confirm the availability of alternate entry paths for DCI in the property.
2. Sufficient capacity for multiple service providers.
b. Supporting documents: Ducts and pathway layout diagrams to verify the
availability on site.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record
maintenance
S. Compliance
Item description requirement
No. (Yes/ No)
(Upload/ DCRA
level)
Ducts layout diagrams from different
1. Record
external entry points for fiber/ DCI
Pathway layout diagrams from ducts
2. Record
to telecom room(s) for fiber/ DCI
Table 5.10: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
Availability of alternate duct from property entry point
1. 3
and cable pathway routes till telecom room(s)
Availability of alternate duct from property entry point
2. 2
till telecom room
Availability of alternate cable pathway routes from
3. 1
common location in property till telecom room(s)
Table 5.11: Scoring criteria
825.2.2. Sub-Criteria: Non-flooding measures for DCI installation
(Weightage – 3)
i. Objective: Flooding can cause significant damage to digital connectivity
infrastructure and disruption in digital connectivity. Measures like raised
installations, waterproof enclosures, and drainage systems may prevent flooding of
key DCI elements. This sub-criterion intends to access the implementation of non-
flooding measures in the property to protect the DCI.
ii. Assessment Methodology:
a. Site Inspection:
1. Check with the site layout and actual location of telecom rooms if they are
located on higher floors, away from potential flooding zones like basements
or ground floors.
2. Verify that power equipment like generator set, UPS, switch over panels are
installed on raised platforms or locations which are less susceptible to
flooding.
3. Verify that no water drain system is connected to the DCI rooms which can
cause backflow.
b. Drainage System Review: Check the availability of drainage systems with
functional checks to prevent backflow of floodwaters.
c. Supporting documents:
1. Design and layout documentation to review infrastructure layouts to verify
that flood prevention measures align with best practices.
2. Sample photographic evidence for key DCI system as proof of
implementation.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record
maintenance
S. Compliance
Item description requirement
No. (Yes/ No)
(Upload/ DCRA
level)
Whether DCI/ telecom room(s)
1. are above ground floor as per Record
design and implementation?
83Record
maintenance
S. Compliance
Item description requirement
No. (Yes/ No)
(Upload/ DCRA
level)
Whether key power systems like
UPS/ Generators for DCI are
2. installed on ground or higher Record
floor with non-flooding
consideration?
Whether drainage system is
3. implemented as per design Record
layout?
Table 5.12: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
Telecom/DCI room(s) and UPS are above ground floor
1. 3 and generators/ switching panels are installed with non-
flooding considerations
Only DCI is implemented above ground floor and backup
2. 2 power system (UPS) is implemented with non-flooding
measure
If DCI and generator system is implemented with non-
3. 1
flooding consideration
Table 5.13: Scoring criteria
5.2.3. Sub-Criteria: Implementation of redundancy in power source and DCI
paths
(Weightage – 4)
i. Objective: The redundant pathways for power and fiber cables inside the property
provide path diversity in extending digital connectivity within and across the floor
or building blocks. Redundancy should be applied to both the power supply and the
connectivity pathways for ensuring that the DCI through other path can take over
without impacting digital connectivity.
ii. Assessment Methodology:
a. Redundancy Verification:
841. Review the DCI for the presence of at least two independent power sources
(e.g., main power grid and backup generators or UPS).
2. Examine the availability of path diversity for fiber or other cables across the
building blocks, basements and towers from digital connectivity
infrastructure room(s).
3. Verify that digital connectivity till key aggregation points is supported by a
minimum of two physically separated paths.
b. Supporting documents:
1. Power and cable layout for DCI indicating path redundancy.
2. Sample test reports demonstrate that actual redundancy performance has
been tested during commissioning.
c. Documentation Review:
1. Verify power and cable layout diagram for DCI indicating path redundancy
with actual implementation.
2. Validate test reports to confirm that redundancy mechanisms function as
intended.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record
maintenance
S. Compliance
Item description requirement
No. (Yes/ No)
(Upload/ DCRA
level)
Whether DCI is supported
1. with redundant power Record
sources (Generator/UPS)?
Whether power system
network layout for DCI is
2. Record
implemented with path
diversity?
Whether sample test reports
3. demonstrate testing of Record
redundancy?
85Record
maintenance
S. Compliance
Item description requirement
No. (Yes/ No)
(Upload/ DCRA
level)
Whether path diversity for
fiber and other cables (DTH/
ethernet as applicable) across
the building blocks,
4. Record
basements and towers from
digital connectivity
infrastructure room(s) is
implemented?
Table 5.14: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
If redundant paths are implemented for power system
1. 4
to DCI and fiber path in the property
If either the power system to DCI or the fiber path
2. 2
incorporate path redundancy
Table 5.15: Scoring criteria
5.3. Future Readiness of Digital Connectivity Infrastructure
(Weightage - 10)
Future readiness in digital connectivity infrastructure ensures that properties are equipped
to support next-generation telecom technologies, evolving connectivity needs and increasing
data demands. Future-ready property may be considered to have been designed to adapt,
scale, and integrate upcoming innovations in digital connectivity, enabling seamless
adoption of emerging technologies like 5G, advanced Wi-Fi and smart building solutions.
5.3.1. Sub-Criteria: Availability of the latest generation of mobile connectivity
(Weightage – 4)
i. Objective: The infrastructure should be equipped to support the latest generation
of mobile connectivity, such as 4G/5G and future network standards, to ensure
high-speed, low-latency, and reliable communication. The availability of advanced
mobile infrastructure significantly impacts digital connectivity performance and
user experience. This sub-criterion focuses on assessing whether a property has the
86necessary infrastructure to support current and next-generation mobile networks
and is future-ready for upcoming technologies.
ii. Assessment Methodology:
a. Inspection of latest technology installed Infrastructure:
1. Physical Verification: Inspect the property’s mobile network
infrastructure, providing coverage to the property including distributed
antenna systems (DAS), and fiber backhaul connectivity.
2. Technology Support: Evaluate if the installed infrastructure is sufficient
to provide coverage in the different areas of the property.
b. Technical Validation:
1. Cross-check compatibility with current frequency bands with different
service providers for latest/ current technology.
c. Supporting documents:
1. List of the latest generation mobile connectivity equipment’s installed in the
property.
2. Photographs of installed latest generation mobile connectivity equipment.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record maintenance
S. Compliance requirement
Item description
No. (Yes/ No) (Upload/ DCRA
level)
Whether the equipment
installed supports the
1. Record
latest generation of
mobile connectivity?
Photographs of installed
2. latest generation mobile Record
connectivity equipment
Table 5.16: Compliance checklist
87iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S.
Weightage Compliance Requirement
No.
If equipment like DAS, RRU, Base Station, etc.
1. 4 supporting 5G technology are installed in the property
for mobile connectivity
If equipment like DAS, RRU, Base Station, etc.
2. 2 supporting 4G technology are installed in the property
for mobile connectivity
Table 5.17: Scoring criteria
5.3.2. Sub-Criteria: Support for future bands
(Weightage - 3)
i. Objective: To ensure long-term relevance and adaptability, digital connectivity
infrastructure must be designed to support the integration of future wireless
communication bands and evolving wired and mobile technologies. The rapid
evolution of telecommunications standards, frequency bands, and network
technologies necessitates a future-proof approach to infrastructure planning. This
enables seamless upgrades, minimizes costly retrofitting, and ensures properties
remain technologically competitive for years to come.
ii. Assessment Methodology:
a. Validate the support or upgradability of installed Digital Connectivity
Infrastructure (DCI) for future bands for latest technology.
b. Verify RF infrastructure installed like radio units, baseband units, duplexers,
combiners and transmitters, as applicable, are capable for supporting upcoming
technologies and frequency bands.
c. Supporting documents:
1. Bill of Material (BoM) installed at the property and datasheets for relevant
equipment.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format.
88Record maintenance
S. Compliance requirement
Item description
No. (Yes/ No) (Upload/ DCRA
level)
Bill of Material (BoM)
installed at building along
1. Record
with datasheets for
relevant equipment
Whether DCI supports
future bands for mobile or
2. Wi-Fi network as Record
applicable as per
datasheets?
Table 5.18: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
If installed infrastructure supports future bands for
1. 3 4G and 5G technology and/or Wi-Fi network as per
the extant frequency roadmap of DoT.
If installed infrastructure supports future bands for
2. 2 4G technology and/or Wi-Fi network as per the
extant frequency roadmap of DoT.
If installed infrastructure supports future bands for
3. 1 4G technology or Wi-Fi network as per the extant
frequency roadmap of DoT.
Table 5.19: Scoring criteria
5.3.3. Sub-Criteria: Upgradability of wireline DCI
(Weightage – 3)
i. Objective: Wireline digital connectivity infrastructure (DCI), such as fiber-optic
networks, plays a crucial role in ensuring high-speed internet access and seamless
communication. As technology evolves, infrastructure must be designed to
accommodate future upgrades, such as higher bandwidth capacities, new
transmission standards, and enhanced network architectures. This sub-criterion
evaluates whether the existing fiber-optic network can be scaled or upgraded without
requiring extensive rework.
89ii. Assessment Methodology:
a. Existing bandwidth verification:
1. Assess the current fiber-optic network’s bandwidth capabilities to determine
if it supports high-speed data transfer (e.g., 1 Gbps, 10 Gbps, or higher).
2. Evaluate the type of fiber used and whether it can support technologies such
as Dense Wavelength Division Multiplexing (DWDM) or Passive Optical
Networks (PON).
b. Scalability review:
1. Inspect the physical infrastructure, including cable pathways, ducts, and
fiber termination points, to verify if additional fiber cables can be added in
the future without major structural modifications.
2. Check the fiber distribution frames to assess whether they allow easy
upgrades or expansions.
3. Determine whether there is spare capacity in existing ducts and conduits to
accommodate additional fiber strands if needed.
c. Supporting documents:
1. Documents to demonstrate upgradability of wireline DCI.
2. Photographic evidence of installed wireline DCI to document their capacity
for future expansion.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record
maintenance
S. Compliance
Item description requirement
No. (Yes/ No)
(Upload/ DCRA
level)
Upgradability of existing
wireline DCI equipment’s
1. Record
(switches/ routers/ splitters/
PON etc.) and relevant cables
90Record
maintenance
S. Compliance
Item description requirement
No. (Yes/ No)
(Upload/ DCRA
level)
Whether the bandwidth
supported through optical
2. Record
fiber with speed 1 Gbps or
higher?
Table 5.20: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S.
Weightage Compliance Requirement
No.
If existing wireline infrastructure is on fiber and support
1. 3
minimum 1 Gbps to end users
If existing wireline infrastructure is on fiber and support
2. 2
minimum 500 Mbps to end users
If existing wireline infrastructure is on fiber and support
3. 1
minimum 100 Mbps to end users
Table 5.21: Scoring criteria
5.4. Provision of Wired Connectivity Infrastructure
(Weightage - 20)
This criterion evaluates the availability, quality, and scalability of the wired connectivity
infrastructure within a property.
A robust wired network ensures high-speed, reliable, and low-latency digital connectivity,
supporting various applications such as business operations, smart building technologies and
residential broadband needs as per property use.
5.4.1. Sub-Criteria: Backhaul fiber connectivity (service provider to property)
(Weightage – 10)
i. Objective: A high-capacity fiber optic backhaul connection is essential to ensure
high-speed and uninterrupted digital connectivity for users within the property. The
presence of a dedicated fiber connection from the service provider to the property
enhances network performance, reduces latency, and supports high-bandwidth
91applications such as video conferencing, cloud computing, and smart building
management systems.
ii. Assessment Methodology:
a. Fiber availability check:
1. Conduct a physical verification of the fiber optic backhaul infrastructure
connected to the service provider’s network.
2. Check redundancy measures, such as dual entry fiber paths, in place for
uninterrupted fiber connectivity in case of failure.
b. Bandwidth verification:
1. Measure and validate the actual peak and average bandwidth available in the
property from all service providers on aggregate level.
2. In the case of business, office or commercial property, check availability of
leased line support on fiber.
c. Supporting documents:
1. Fiber cable details form service providers to the property and supporting
documents regarding available bandwidth from each service provider on
fiber.
d. Documentation Review: Validate the Telecom/ Internet service provider
agreements and fiber/ bandwidth testing results.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record maintenance
Compliance
S. No. Item description requirement (Upload/
(Yes/ No)
DCRA level)
1. Fiber testing results Record
Photographs of fiber
2. termination point at Record and Upload
main telecom room
Table 5.22: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
92S. No. Weightage Criteria
(No. of wireline service providers
Weightage
having fiber backhaul)
awarded =
10* (No. of wireline service providers
present in the property)
(If number of wireline service providers in property are
1. 10 >=3)
Note: In the case of wireline service providers there are
less than three, the above formula will apply considering
50% weightage (i.e. 5 in place of 10) against this
parameter
Table 5.23: Scoring criteria
5.4.2. Sub-Criteria: Fiber connectivity till user premises
(Weightage – 5)
i. Objective: Sub-criterion assesses whether high-capacity fiber-optic infrastructure
is extends up to the end-users within a property. The aim is to ensure that residents,
businesses, and offices benefit from high-speed, reliable internet connectivity. A
fiber-optic connection reaching the user premises guarantees superior bandwidth,
lower latency, and future-proof infrastructure capable of supporting evolving digital
requirements such as 5G backhaul, cloud services, and smart building applications.
The well planned and laid fiber cables from telecom room(s) to the user premises
(flat/home/office/shop etc. as applicable) enables faster provisioning and easy to
maintain.
ii. Assessment Methodology:
a. Physical Inspection: Verify that fiber-optic cabling extends up to each
residential, office, or commercial unit within the property.
b. Supporting documents:
1. Fiber network architecture showing fiber distribution from the telecom/
room or meeting point to each unit.
2. Fiber test reports confirming connectivity to each unit
iii. Compliance check list: The DCRAs shall prepare and maintain the compliance
93summary in the following format:
Record maintenance
S. Compliance
Item description requirement (Upload/
No. (Yes/ No)
DCRA level)
Fiber layout diagrams up
1. Record and Upload
to user premises
Sample fiber test reports
2. confirming connectivity Record and Upload
to each user premise
Table 5.24: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
If fiber connectivity is extended to all user units within
1. 5
the property
If fiber connectivity is extended to a minimum of 50%
2. 3
of user units within the property
If fiber connectivity is extended to a minimum of 30%
3. 1
of user units within the property
Table 5.25: Scoring criteria
5.4.3. Sub-Criteria: Fiber connectivity in each room or office or commercial
space
(Weightage – 5)
i. Objective: The goal of this sub-criterion is to assess whether every individual space
within the property, whether a residential unit, office, or commercial
establishment—has fiber connectivity. This guarantees seamless high-speed
internet access across the entire property, eliminating connectivity dead zones and
ensuring a uniform digital experience for all occupants.
ii. Assessment Methodology:
a. Visual Inspection: Inspect rooms, offices, or commercial spaces on a sample
basis to confirm the presence of fiber-optic connectivity infrastructure and
termination points in each room/ office.
94b. Supporting documents:
1. Network layout diagram for user units showing fiber terminations and
sample test reports for fiber terminations.
2. Site survey reports and photographic evidence.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record maintenance
S. Item Compliance
requirement (Upload/
No. description (Yes/ No)
DCRA level)
Network layout
diagram for user
1. Record
units showing fiber
terminations
Sample test
reports for fiber
2. Record and Upload
terminations
testing
Table 5.26: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
If fiber connectivity is extended in each room/ office/
1. 5
commercial space of all user units within the property
If fiber connectivity is extended in each room/ office/
2. 3 commercial space of minimum 50% of user units
within the property
If fiber connectivity is extended in each room/ office/
3. 1 commercial space of minimum 30% of user units
within the property
Table 5.27: Scoring criteria
5.5. Availability of Service Providers
(Weightage - 15)
This criterion evaluates the number and diversity of wireline and mobile service providers
that have integrated their services with the Digital Connectivity Infrastructure (DCI) of a
property. A higher number of available providers ensure better service quality, redundancy
and consumer choice.
955.5.1. Sub-Criteria: Number of wireline Internet Service providers having
integration with Digital Connectivity Infrastructure
(Weightage - 7.5)
i. Objective: The presence of multiple wireline Internet Service Providers (ISPs)
within a property significantly enhances competition, service quality, redundancy,
and network resilience, ensuring reliable and high-speed digital connectivity. A
multi-ISP infrastructure benefits property managers, businesses, and residents by
providing greater flexibility, improved service continuity, and optimized cost
structures.
ii. Assessment Methodology:
a. Verification of ISP Integration: Confirm the number of wireline TSP/ ISPs
integrated with the DCI by inspecting the infrastructure and service availability.
b. Telecom/Internet Service Provider Agreement Review: Verify
agreements with TSP/ ISPs and sample integration test reports.
c. Validation: Verify that all integrated TSP/ ISPs are operational.
d. Supporting documents:
1. Telecom/ Internet Service Provider (TSP/ ISP) Agreements.
2. Network integration certificates/ test reports.
3. Service subscription status.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record maintenance
Item Compliance
S. No. requirement (Upload/
description (Yes/ No)
DCRA level)
Telecom/
Internet Service
1. Record
Provider (ISP)
Agreements
Network
integration
2. Record
certificates/test
reports
96Record maintenance
Item Compliance
S. No. requirement (Upload/
description (Yes/ No)
DCRA level)
Service
3. subscription Record
status
Table 5.28: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S.
Weightage Compliance Requirement
No.
If 3 or more internet service providers have integration
1. 7.5
with DCI in the property with active service subscription
If a minimum of 2 internet service providers have
2. 5 integration with DCI in the property with active service
subscription
If at least one internet service provider has integration
3. 2
with DCI in the property with active service subscription
Table 5.29: Scoring criteria
5.5.2. Sub-Criteria: Number of Mobile Service providers having coverage or
integration with Digital Connectivity Infrastructure
(Weightage – 7.5)
i. Objective: The objective of this sub-criterion is to assess the extent to which
multiple mobile service providers (TSPs) are integrated with the property’s digital
connectivity infrastructure (DCI) or have adequate service coverage as per sub-
criteria 8.1. Having multiple mobile service providers ensures users have reliable
network coverage, high-quality service, and reduced congestion, particularly in high-
density areas like commercial properties, residential complexes, and office spaces.
ii. Assessment Methodology:
a. Coverage Verification:
1. Confirm the number of Telecom Service Providers (TSPs) providing indoor
coverage for the property.
2. Validate integration of the DCI with In-Building Solutions (IBS)/ Small
Cells/ Wi-Fi offload for enhanced indoor mobile coverage.
97b. Supporting documents:
1. Agreements signed with Telecom Service Providers.
2. RF coverage map in the property or walk/ drive test results.
c. Documentation Review: Validate the TSP agreements and network
integration test reports.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record
maintenance
Compliance
S. No. Item description requirement
(Yes/ No)
(Upload/ DCRA
level)
RF coverage map in the
property or walk/ drive
1. Record and Upload
test results
Network performance test
2. results from multiple Record
operators
Agreements signed with
Telecom Service Providers
3. Record
(without commercial
details)
Table 5.30: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
If 3 or more mobile service providers have integration with
1. 7.5 DCI in the property or more 75% coverage in indoor area of
the property
If at least two mobile service providers have integration
2. 5 with DCI in the property or more 75% coverage in indoor
areas
If at least one mobile service provider has integration with
3. 2
DCI in the property or more 75% coverage in indoor areas
Table 5.31: Scoring criteria
985.6. Service Performance
(Weightage - 25)
Service performance is a critical factor in evaluating the digital connectivity of a property.
This criterion assesses service performance parameters to assess digital experience in the
property including lifts and basements. For assessment of mobile service coverage, the
reference minimum signal strength for 2G/4G/5G technology shall be same as prescribed by
TRAI for publishing of coverage map under revised QoS regulation i.e. ‘THE STANDARDS
OF QUALITY OF SERVICE OF ACCESS (WIRELINE AND WIRELESS) AND BROADBAND
(WIRELINE AND WIRELESS) SERVICE REGULATIONS, 2024 (06 of 2024)’.
5.6.1. Sub-Criteria: Mobile network coverage and performance in public areas
of property
(Weightage – 5)
i. Objective: The mobile network performance in public areas (e.g., lobbies,
corridors) should meet minimum requirements for signal strength and speed which
is essential for superior user experience, safety, and efficient operations.
ii. Assessment Methodology:
a. Conduct RF testing for mobile coverage in public spaces like lobbies, corridors,
common utilities like gym, banquet hall, garden, parking, lifts, basements and
entrances using industry standard tools.
b. Assess data speed and voice call quality over a day (preferably 10 am to 8pm with
samples uniformly distributed covering peak hours in property) using test probes
for each service provider whose coverage is available on the property and
accounted under criteria 7- Availability of Service Providers’. Measurements to
be carried out shall include peak as well as off-peak hours.
c. Supporting documents:
1. RF coverage map/ test results of public areas.
2. Speed test logs and call quality reports.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
99Record maintenance
S. Compliance
Item description requirement (Upload/
No. (Yes/ No)
DCRA level)
RF coverage map of
1. Record and Upload
public areas
Speed test logs and call
2. Record and Upload
quality reports
Table 5.32: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
If at least 3 service providers have more than 85%
mobile coverage for their latest generation of
1. 5 technology in public areas (including lifts and
basements) with signal strength as prescribed for
network coverage map by TRAI.
If at least two service providers have more than 85%
mobile coverage for their latest generation of
2. 3 technology in public areas (including lifts and
basements) with signal strength as prescribed for
network coverage map by TRAI.
If at least one service provider has more than 85%
mobile coverage for their latest generation of
3. 2 technology in public areas (including lifts and
basements) with signal strength as prescribed for
network coverage map by TRAI.
Table 5.33: Scoring criteria
5.6.2. Sub-Criteria: Secure public Wi-Fi network coverage and performance in
public areas of property
(Weightage – 5)
i. Objective: Public Wi-Fi in the property may complement the mobile coverage.
However, it should be secure and offer a high level of performance, with fast speeds
and low latency. With secure and seamless public Wi-Fi coverage in the property,
consumers can avail the data and voice service. The assessment shall include
evaluating its Wi-Fi network availability, security measures in place, speed, and
latency required for reliable digital connectivity.
10
0ii. Assessment Methodology:
a. Identify all public areas within the property where Wi-Fi services are provided,
such as lobbies, lounges, cafeterias, parking areas, lifts, basements and open
seating spaces.
b. Conduct sample WPA2/ WPA3 compliance checks for security.
c. Conduct coverage, speed and latency tests covering peak hours using industry
standard tools.
iii. Supporting documents:
1. Wi-Fi Coverage Maps: Diagrams or heatmaps showcasing Wi-Fi coverage
across the property, highlighting areas with weak or strong signals.
2. Speed Test Results: Logs of speed and latency test results from different
locations and times, demonstrating network reliability.
3. Wi-Fi Security Audit Reports: Reports confirming compliance with WPA2/
WPA3 security standards, network authentication mechanisms, and encryption
configurations.
iv. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record maintenance
S. Compliance
Item description requirement (Upload/
No. (Yes/ No)
DCRA level)
Wi-Fi coverage
1. maps and speed test Record and Upload
results
Wi-Fi security audit
2. Record and Upload
reports
Table 5.34: Compliance checklist
v. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
10
1S.
Weightage Compliance Requirement
No.
If secure Wi-Fi coverage is available in more than 85% of
1. 5 public or common area of the property (including lifts and
basements)
If secure Wi-Fi coverage is available in more than 75% of
2. 3 public or common area of the property (including lifts and
basements)
If secure Wi-Fi coverage is available in more than 65% of
3. 2 public or common area of the property (including lifts
and basements)
Table 5.35: Scoring criteria
5.6.3. Sub-Criteria: Mobile network coverage and performance in non-public
areas
(Weightage – 5)
i. Objective: The mobile network should maintain high performance in private or
restricted areas, such as residential flats, offices, conference rooms, lifts, basements,
executive cabins etc. within a property. The objective of this criterion is to assess the
availability of mobile network coverage in private areas of the property.
ii. Assessment Methodology:
a. Conduct RF testing for mobile coverage in pre-defined non-public areas using
industry standard tools.
b. Monitor and assess data speed, video quality and voice call quality over a day
using probes. Measurement to be carried out covering peak hours of traffic in the
property.
iii. Supporting documents:
1. RF coverage map of areas under test or drive test results.
2. Speed test logs, call setup success rate and quality (Mean Opinion Score)
reports for minimum 100 calls.
iv. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
10
2Record maintenance
S. Item Compliance
requirement (Upload/
No. description (Yes/ No)
DCRA level)
RF coverage map
1. Record and Upload
of areas under test
Speed test logs
and call setup and
2. Record and Upload
call quality
reports
Table 5.36: Compliance checklist
v. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S.
Weightage Compliance Requirement
No.
If at least 3 service providers have more than 80% mobile
coverage for their latest generation of technology in non-
1. 5 public areas (including lifts and basements) with
minimum download speed of 10Mbps for 4G or 100 Mbps
for 5G technology as applicable.
If at least 2 service providers have more than 70% mobile
coverage for their latest generation of technology in non-
2. 3 public areas (including lifts and basements) with average
minimum download speed of 10Mbps for 4G or 100 Mbps
for 5G technology as applicable.
If at least 2 service providers have more than 50% mobile
coverage for their latest generation of technology in non-
3. 2 public areas (including lifts and basements) with average
minimum download speed of 10Mbps for 4G or 100 Mbps
for 5G technology as applicable.
Table 5.37: Scoring criteria
Note: Download speed to be tested through TRAI App.
5.6.4. Sub-Criteria: Secure public Wi-Fi network coverage and performance in
non-public areas
(Weightage – 5)
i. Objective: Public Wi-Fi in the property may complement the mobile coverage.
However, it should be secure and offer a high level of performance, with fast
speeds and low latency. With secure and seamless public Wi-Fi coverage in the
10
3property, consumers can avail the data and voice service. The goal is to assess Wi-
Fi coverage in non-public areas, such as residential flats, enterprise workspaces,
executive offices, lifts, basements, conference rooms, etc. These areas require
reliable, high-speed, and encrypted Wi-Fi connectivity to support business
operations, data security, and seamless enterprise communication.
ii. Assessment Methodology:
To evaluate compliance with this sub-criterion, the following steps will be
undertaken:
a. Identify all non-public areas within the property where Wi-Fi services are
provided.
b. Conduct sample WPA2/WPA3 compliance checks for security.
c. Conduct coverage, speed and latency tests covering peak hours using industry
standard tools.
iii. Supporting documents:
a. Wi-Fi Coverage Maps: Diagrams or heatmaps showing Wi-Fi coverage across
the property in non-public areas, highlighting areas with weak or strong signals.
b. Speed Test Results: Logs of speed and latency test results from different
locations and times, demonstrating network reliability.
c. Wi-Fi Security Audit Reports: Reports confirming compliance with WPA2/
WPA3 security standards, network authentication mechanisms, and encryption
configurations.
iv. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record maintenance
S. Compliance
Item description requirement (Upload/
No. (Yes/ No)
DCRA level)
Wi-Fi security
1. Record
certifications
Wi-Fi coverage maps
2. and speed test Record and Upload
results
Table 5.38: Compliance checklist
10
4v. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S.
Weightage Compliance Requirement
No.
If secure Wi-Fi coverage is available in more than 85% of
non- public areas (including lifts and basements) of the
1. 5
property with minimum download speed of 20 Mbps in
peak hours
If secure Wi-Fi coverage is available in more than 75% of
non-public areas (including lifts and basements) of the
2. 3
property with minimum download speed of 20 Mbps in
peak hours
If secure Wi-Fi coverage is available in more than 65% of
non-public areas (including lifts and basements) of the
3. 2
property with minimum download speed of 20 Mbps in
peak hours
Table 5.39: Scoring criteria
Note: Download speed to be tested through TRAI App.
5.6.5. Sub-Criteria: Average download speed of different wireline network(s)
in respective highest speed plan
(Weightage – 5)
i. Objective: The objective of this sub-criterion is to assess the highest average
download speed supported by different wireline networks or service providers under
their offered plans in the property.
ii. Assessment Methodology:
a. Conduct speed tests using standard tools (TRAI My Speed App). Conduct tests
during peak traffic hour(s) at least at five different user locations.
b. Compare results against advertised speeds under highest plan by respective ISP
in highest tier plans. Compare actual speed test results with these promised
speeds.
c. Supporting documents: Speed test results with timestamps.
iii. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
10
5Record maintenance
S. Item Compliance
requirement (Upload/
No. description (Yes/ No)
DCRA level)
1. Speed test
results with Record and Upload
timestamps
Table 5.40: Compliance checklist
iv. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S.
Weightage Compliance Requirement
No.
If download speed of any wireline network is more than
1. 5
500 Mbps
If the download speed of any wireline network is more
2. 3
than 250 Mbps
If the download speed of any wireline network is more
3. 2
than 100 Mbps
Table 5.41: Scoring criteria
5.7. User Experience
(Weightage - 10)
User experience assesses user feedback on digital connectivity, including network reliability,
speed, latency, and ease of access. It considers factors like seamless browsing, streaming
quality and minimal disruptions. A positive experience indicates robust connectivity, while
frequent issues highlight areas for improvement.
5.7.1. Sub-Criteria: User feedback on digital connectivity experience
(Weightage – 10)
i. Objective: The objective of this sub-criterion is to collect and analyze user feedback
regarding their experience with mobile, wireline, and Wi-Fi services in a property.
User insights help assess the real-world performance of the digital connectivity
infrastructure, identify gaps in service quality and drive improvements to enhance
the overall connectivity experience.
10
6ii. Assessment Methodology:
a. Conduct structured surveys capturing user satisfaction on voice call quality, voice
call accessibility, voice call retainability, data speed (wireline and wireless),
latency, service uptime and coverage.
b. The feedback should be collected from a minimum of 10% of the users of the
property if the total users are less than 1000. In case total users are more than
1000, then feedback may be collected from a minimum of 100 users. The users in
survey should be distributed across gender and broad adult age groups.
iii. Supporting documents:
1. User feedback form (please refer to Appendix section for the indicative feedback
form).
iv. Compliance checklist: The DCRAs shall prepare and maintain the compliance
summary in the following format:
Record maintenance
S. Compliance requirement
Item description
No. (Yes/ No) (Upload/ DCRA
level)
1. User feedback form Record and Upload
Table 5.42: Compliance checklist
v. Scoring criteria: The DCRA shall award score against this sub-criterion as
follows:
S. No. Weightage Compliance Requirement
If 80% of users provide overall positive experience for
1. 10
digital connectivity in the property
If 70% of users provide overall positive experience for
2. 8
digital connectivity in the property
If 50% of users provide overall positive experience
3. 6
for digital connectivity in the property
If 40% of users provide overall positive experience for
4. 4
digital connectivity in the property
Table 5.43: Scoring criteria
10
75.8. Summary of Rating Score
After assessing and scoring against each criterion and sub-criteria as per assessment
methodology, the DCRA shall prepare the summary of rating score in following format for
final updating in the rating platform for generating the rating certificate:
Sub Score
Criteria Criteria Weightage Sub-Criteria Criteria awarded
No. [a] [b] [c] Weightage by
[d] DCRA
5.1.1 Redundancy of
Provision in 2
power source
power
5.1.2 UPS power backup
infrastructure 4
for DCI
5.1 for ensuring 10
5.1.3 Power continuity
reliable 2
monitoring
digital
5.1.4 Building
connectivity 2
Management System
5.2.1 Availability of
alternate entry paths for
3
digital connectivity
Digital infrastructure
Connectivity 5.2.2 Non-flooding
5.2 10
Infrastructure measures for DCI 3
Resilience installation
5.2.3 Implementation of
redundancy in power 4
source and DCI paths
5.3.1 Availability of the
Future latest generation of 4
Readiness of mobile connectivity
5.3 Digital 10 5.3.2 Support for future
3
Connectivity bands
Infrastructure 5.3.3 Upgradability of
3
wireline DCI
5.4.1 Backhaul fibre
Provision of
connectivity (service 10
Wired
5.4 20 provider to property)
Connectivity
5.4.2 Fibre connectivity
infrastructure 5
till user premises
10
8Sub Score
Criteria Criteria Weightage Sub-Criteria Criteria awarded
No. [a] [b] [c] Weightage by
[d] DCRA
5.4.3 Fibre connectivity
in each room or office or 5
commercial space
5.5.1 Number of wireline
Internet Service
providers having
7.5
integration with Digital
Connectivity
Availability of
Infrastructure
5.5 Service 15
5.5.2 Number of Mobile
Providers
Service providers having
coverage or integration
7.5
with Digital
Connectivity
Infrastructure
5.6.1 Mobile network
coverage and
5
performance in public
areas of property
5.6.2 Secure public Wi-
Fi network coverage and
5
performance in public
areas of property
5.6.3 Mobile network
coverage and
Service 5
5.6 25 performance in non-
Performance
public areas
5.6.4 Secure public Wi-
Fi network coverage and
5
performance in non-
public areas
5.6.5 Average download
speed of different
wireline network(s) in 5
respective highest speed
plan
10
9Sub Score
Criteria Criteria Weightage Sub-Criteria Criteria awarded
No. [a] [b] [c] Weightage by
[d] DCRA
5.7.1 User feedback on
User
5.7 10 digital connectivity 10
Experience
experience
Table 5.44: Summary of Rating Score
11
06. Award of Rating and Renewal
The Digital Connectivity Rating is a standardized measure used to evaluate the quality,
reliability, and readiness of a property's digital infrastructure and on ground service
performance. The rating process assesses multiple factors, including infrastructure,
regulatory compliance, service performance, and user experience.
Once the assessment is completed, a final rating is assigned, helping property owners,
tenants, and service providers make informed decisions regarding digital connectivity in that
location. The rating also plays a crucial role in attracting potential businesses and residents
who prioritize seamless digital connectivity.
Additionally, this rating is subject to renewal at periodic intervals, ensuring that properties
maintain or improve their connectivity standards over time.
6.1. Classification of Ratings
Following the detailed assessment process outlined in Section 4 of this manual, a cumulative
score is assigned to each property. Based on this score, a corresponding Digital Connectivity
Rating from 1 star to 5 star is awarded, which serves as an indicator of the property's
readiness to support high-speed and reliable digital services.
Digital Connectivity Rating to be
S. No. Score Range
awarded
1. 25-40
2. 41-55
3. 56-70
4. 71-85
5. More than 85
Table 6.1: Rating Scorecard
6.2. Validity Period of Ratings
The validity period refers to the duration for which a property’s Digital Connectivity Rating
remains effective before requiring reassessment and renewal.
The difference in validity periods between categories is likely based on factors such as:
11
1i. Infrastructure Stability – Well-equipped properties with robust digital
infrastructure may have longer validity periods.
ii. Usage and Demand – Properties with higher connectivity demands may require
more frequent reassessments.
iii. Regulatory Compliance – Changes in technology standards and regulations may
impact validity duration.
The validity period for Category ‘A’ Category and ‘B’ properties shall be as prescribed by the
Authority from the date of issue of the rating certificate.
6.3. Reassessment Process
To ensure the continued accuracy and relevance of digital connectivity ratings, DCRA
provides a structured mechanism for property managers to apply for re-rating within the
validity period of the existing digital connectivity rating certificate (Regulation 29).
This process enables properties to reflect infrastructure upgrades, technological
advancements, and regulatory compliance improvements, ensuring that the rating remains
aligned with the latest connectivity standards.
6.3.1. Eligibility Criteria for Re-rating
A property shall be eligible for re-rating under the following circumstances:
i. Full upgrade of Digital connectivity infrastructure (DCI): If a property has
undergone a comprehensive enhancement of its telecom infrastructure, the property
manager may seek re-rating to reflect the improvements. Such upgrades may
include:
a. Expansion of fiber optic networks.
b. Installation of in-building solutions to improve indoor coverage.
c. Enhancement of power backup systems for digital infrastructure to ensure.
seamless connectivity.
d. Integration of smart network management systems.
ii. Technological upgradation leading to demand for Re-rating by end
users: If there has been a significant upgrade in the technology deployed at the
property and end users or tenants demand a reassessment, a re-rating may be
considered. Examples of such technological advancements include:
a. Deployment of 5G, Wi-Fi or high-speed fiber networks to enhance connectivity.
b. Significant improvements in broadband speed, latency, and network resilience.
c. Implementation of next-generation digital services, such as IoT-enabled
automation.
11
2d. Increased demand for an upgraded rating due to expanding digital service
requirements from occupants, enterprises or businesses operating within the
property.
iii. Other changes affecting the rating as per regulatory criteria
If any modifications or improvements impact the property’s compliance with DCRA
rating parameters, a re-rating application may be submitted. Such changes may
include:
a. Increase in the number of telecom service providers offering wired or wireless
services at the property
b. Upgraded compliance with Model Building Bye-Laws (MBBL) and National
Building Code (NBC) for digital infrastructure
c. Expansion of telecom facilities to previously underserved areas within the
property, ensuring enhanced access
d. Improvement in service reliability, redundancy, and fault tolerance mechanisms
6.4. Renewal Process
To ensure the continuity of a property’s digital connectivity rating, DCRA mandates that
property managers apply for renewal of their rating before its expiry.
The renewal process ensures that properties continue to meet the regulatory, technical, and
service performance standards required for maintaining their digital connectivity
classification (Regulation 19). The property manager may apply for renewal of ratings well in
advance for continuity of rating for the property.
6.4.1. Application Timeline and Submission
A property manager who intends to renew the digital connectivity rating certificate for a
property under their ownership, control, or management must submit a renewal
application on the rating platform at least 120 days prior to the expiry of the existing rating.
This advance submission ensures sufficient time for assessment, verification, and issuance
of the renewed certificate without any lapse in rating status.
The renewal application may include:
i. Any changes or upgrades made to the digital connectivity infrastructure since the last
assessment.
ii. A self-declaration of continued compliance with the applicable Model Building Bye-
Laws (MBBL), National Building Code (NBC), and DCRA guidelines.
iii. Payment of the renewal processing fee as per the prescribed schedule.
11
3The application for renewal shall be made through the rating platform.
6.4.2. Assessment and Verification Process
Upon receiving the renewal request, DCRA will undertake a comprehensive reassessment
to verify that the property still meets the required connectivity standards. The assessment
process shall be similar to that followed for award of ratings first time and may inter-alia
include:
i. Review of documentation: Validation of submitted records, compliance reports,
and service provider agreements.
ii. Infrastructure inspection: A physical or digital audit of the property’s telecom
infrastructure, ensuring continued adherence to the original rating criteria.
iii. Performance evaluation: Assessment of service reliability, network availability,
user feedback, and any upgrades implemented since the last rating period.
iv. Regulatory compliance check: Verification of compliance with MBBL, NBC, and
other applicable digital infrastructure standards.
If the property meets or exceeds the required standards, the Digital Connectivity Rating
Certificate will be renewed for the next validity period.
6.4.3. Renewal Outcome and Rating Status
The property will receive a renewed rating certificate, valid for the next certification cycle, with
updated documentation reflecting the latest assessment.
11
47. Reporting and Feedback Mechanism
A well-defined stakeholder reporting and feedback mechanism is essential for maintaining
transparency, accountability, and continuous improvement in the digital connectivity rating
process for properties. This mechanism ensures that all stakeholders, including property
managers, telecom service providers, infrastructure providers, and end users have a structured
platform to report issues against the rated, provide feedback, and suggest improvements to the
property manager related to digital connectivity within rated properties.
7.1. Monitoring and Reporting Mechanism
DCRA is responsible for overseeing feedback and complaints related to the ratings awarded
to properties throughout the rating certificate’s validity as per following provisions regulation
11.
i. “Every DCRA shall monitor feedback or complaints received from service
providers or end users during the validity of the rating certificate of the
properties, as received through the rating platform, concerning the ratings
awarded by DCRA.
ii. Every DCRA shall examine feedback or complaints received under sub-regulation
(1) and evaluate the need for either review of rating awarded or corrective actions
required by the property manager and take follow up action with the property
manager, if required, for resolving such identified issues.”
7.2. Mechanism for Stakeholder Feedback
A standardized feedback mechanism will be provided in the rating platform to enable
feedback-based oversight on the status of digital connectivity in rated properties during
validity of ratings. Stakeholder feedback will be made available to the concerned property
manager and DCRA against each rated property. The stakeholders will be required to validate
themselves to submit feedback through the platform. The feedback from the stakeholders
shall be supported with relevant evidence(s).
The high-level approach for feedback lifecycle will include:
i. Feedback Categories:
a. Connectivity Performance: Reports on issues such as poor network
coverage, insufficient infrastructure, or slow internet speeds.
b. Infrastructure Gaps: Identification of areas requiring upgrades to meet TRAI
standards.
c. General Suggestions: Recommendations to improve the overall framework
and efficiency.
11
5ii. Feedback Processing and Resolution by property manager:
a. Acknowledgment: Feedback will be acknowledged automatically by rating
platform.
b. Review and evaluation: All feedback received during a month/ quarter
(based on volume of feedback or issues) will be reviewed by the property
manager for evaluation of any corrective action required. In case any corrective
action is proposed, it will be updated on the rating platform for information of
concerned stakeholders. In addition, property managers may also use other
channels of communication for this purpose.
iii. Yearly review of stakeholder feedback by DCRA:
DCRA shall review the issues and feedback reported by stakeholders at least on a
yearly basis from the date of issue of rating certificate. However, in the case of large
number of feedback/complaints for any rated property, DCRA shall undertake
review as per requirement or as directed by the Authority. The summary report of
such reviews covering analysis of feedback, conclusion and recommended actions by
the property manager, if any, shall be uploaded against each property.
iv. Corrective action by the property manager:
The property manager concerned shall take corrective action, if any recommended
by DCRA, in a time-bound manner within the timelines suggested by the DCRA. The
action taken report by the property manager shall be uploaded against the property
for review by the DCRA and closure of observations.
7.3. Addressing Non-Compliance
Any instance of non-compliance by the property manager or DCRA shall be dealt in
accordance with the provisions of the regulations.
11
68. Appeal Process
To uphold transparency, fairness, and accountability, the rating framework provides a
structured appeal process for property managers who wish to challenge their assigned rating.
This section details the procedures, timelines, and regulatory provisions governing appeals,
ensuring they are handled promptly and impartially.
The appeal process, under regulation 27, offers property managers a formal mechanism to
request a review of their rating if they believe the assessment does not accurately represent the
digital connectivity infrastructure of their property.
8.1. Filing of Appeal by Property Manager
Property managers who are dissatisfied with the Digital Connectivity Rating assigned to their
property by DCRA may file an appeal through the rating platform. The appeal process ensures
a fair opportunity for property managers to challenge their rating based on valid concerns
and supporting evidence. The appeal must be submitted within 30 days of the date of
issuance of the rating certificate as per the sub-clause (1) of regulation 27.
The appeal justification may include the following:
i. Justification for the appeal, citing specific criteria and sub-criteria that require
reconsideration.
ii. Supporting documentation, technical reports, or third-party assessments validating
the concerns raised.
iii. Any additional evidence demonstrating improvements in digital connectivity
infrastructure that may not have been considered during the initial rating
assessment.
8.2. Review of Appeal by DCRA
Once an appeal is submitted, the Digital Connectivity Rating Agency (DCRA) concerned will
conduct a review of the rating assessment against indicated criteria or sub-criteria under
appeal. DCRA shall evaluate the grounds of appeal, verify the submitted evidence, and, if
necessary, conduct a re-evaluation of the property’s connectivity infrastructure for respective
parameter(s) as may be required.
A final decision on the appeal will be made within 60 days of receipt of the appeal, following
the process outlined by the Authority.
If the review finds merit in the appeal, DCRA may:
i. Revise the rating based on newly presented evidence.
ii. Uphold the original rating if no discrepancies or new qualifying factors are identified.
11
7iii. Recommend corrective actions to the property manager for potential re-rating in the
future.
8.3. Escalation of Appeal to the Authority
If the property manager is still not satisfied with the decision of the DCRA, they may escalate
the appeal to the Telecom Regulatory Authority.
i. The escalation must be filed within 30 days from the date of DCRA’s appeal decision.
ii. The appeal must be submitted in the prescribed format and include all necessary
documentation.
iii. A specified fee, as determined by the Authority, must accompany the appeal
submission.
iv. No appeal shall be entertained by the Authority after expiry of the period as provided
under the regulations.
8.4. Examination of Appeal by Authority
Upon receiving an escalated appeal, the Telecom Regulatory Authority will conduct an
independent review to ensure that the final decision is fair and justified.
i. Independent Case Assessment: The Authority may directly evaluate the case
based on submitted evidence and regulatory provisions.
ii. Expert Panel Review: The Authority may appoint a specialized panel of experts
to conduct a detailed examination and provide recommendations.
The Authority shall ensure that all relevant technical, regulatory, and procedural aspects
are evaluated before making a final decision.
11
89. Review and Updates of Rating Manual
To ensure that the Digital Connectivity Rating Manual remains relevant, accurate, and aligned
with industry advancements, a structured review and update process will be undertaken at
regular intervals. This process will account for technological evolution, regulatory changes,
stakeholder feedback, and performance insights, ensuring that the rating framework remains
effective in assessing and improving digital connectivity in properties.
9.1. Process for Periodic Updates
To maintain the relevance, accuracy, and effectiveness of the rating manual for digital
connectivity inside properties, periodic updates will be conducted through a structured and
inclusive approach.
The process begins with stakeholder feedback collection, where inputs from key entities such
as property managers, DCRAs, telecom service providers, infrastructure providers, and
technical experts are gathered. This helps identify gaps, challenges, and areas for
improvement in existing rating criteria.
Based on insights from stakeholder feedback and benchmarking, a draft revision of the
manual will be developed, incorporating necessary modifications and refinements. This draft
will then undergo validation through expert reviews, where subject matter specialists will
assess the proposed changes to ensure technical accuracy, regulatory compliance, and
feasibility of implementation.
This structured process guarantees that the rating manual remains adaptive, future-ready,
and reflective of the latest industry advancements, thereby promoting high-quality, resilient,
and future-proof digital connectivity infrastructure in properties.
11
910. Best Practices for Digital Connectivity in Properties
To ensure high-quality, resilient, and future-ready digital connectivity in properties, a
structured set of guidelines and best practices help to minimize cost, improve aesthetics and
improve user experience. These best practices are indicative in nature to help property
managers, infrastructure providers, and telecom service providers in designing and
implementing digital connectivity solutions that meet current and future technological
requirements while ensuring seamless user experience.
10.1. Best Practices for Digital Connectivity
To ensure high-quality digital connectivity in properties, the following best practices should
be adopted:
i. Digital Connectivity Infrastructure Planning
Digital connectivity infrastructure should be planned right from the building design
stage like plan for water, fire system and electricity. Incorporating digital
connectivity infrastructure during the initial design phase of a property is critical for
seamless deployment of broadband and wireless technologies while reducing
considerable cost compared to retrofitting of DCI.
Key considerations include:
a. Conduit and Cable Pathways: Ensuring dedicated and well-structured
pathways for fiber optic and ethernet cables, avoiding bottlenecks and future
installation challenges.
b. Dedicated Telecom Spaces: Allocating sufficient space for telecom rooms,
network equipment and distribution points within the building.
c. Regulatory Compliance: Aligning digital connectivity infrastructure with
Model Building Byelaws (MBBL), National Building Code (NBC), and telecom
regulations to avoid future rework or legal issues.
d. Collaboration with Telecom Service Providers: Engaging with telecom
service providers and DCI design experts in early in the project to ensure optimal
network design.
The National Building Code may be referred to for further details which provides
detailed guidelines for planning digital connectivity/ ICT infrastructure in the
buildings.
12
0ii. High Speed Internet Readiness:
To meet the increasing demand for high-speed, low-latency internet, properties
should:
a. Deploy fiber optic backbone connectivity as the primary infrastructure for
internet distribution. Fiber-optic networks offer higher bandwidth capacity, faster
speeds, and lower latency compared to traditional copper-based networks.
b. Ensure multiple fiber entry points in the property to enable connectivity from
different ISPs, increasing network resilience and competition-driven pricing
benefits for end-users.
c. Provision scalable bandwidth options to accommodate future demands,
ensuring seamless support for 5G, IoT, AI applications, and cloud services.
d. Implement structured cabling systems (Category 6/6A and fiber optic cabling)
for internal network distribution, ensuring high-speed connectivity across all areas
of the property.
iii. Wireless Network Optimization
Wireless connectivity plays a pivotal role in digital infrastructure, and optimized
in-building solutions are essential for ensuring uninterrupted coverage and high-
speed connectivity. Key strategies include:
a. Distributed antenna systems (DAS): Deploying DAS solutions to enhance
cellular coverage in large properties, high-rise apartments, and commercial spaces,
eliminating dead zones.
b. Small cells deployment: Installing small cell technology in dense urban
environments to boost wireless network capacity, particularly for 4G and 5G
networks.
c. Wi-Fi offloading and optimization: Implementing high-density Wi-Fi
solutions to offload mobile data traffic, ensuring optimal indoor coverage and
performance.
d. Intelligent network management: Leveraging AI-driven self-optimizing
networks (SON) to dynamically adjust power levels, frequencies, and coverage
areas for enhanced user experience.
12
1iv. Redundancy and Resilience
To prevent service disruptions and downtime, properties must integrate robust
redundancy and resilience measures in their digital connectivity infrastructure. These
include:
a. Multiple ISP Connections: Establishing connectivity from two or more internet
service providers to ensure a failover in case of a primary network outage.
b. Backup Power Supply: Ensuring continuous operation of network equipment
through uninterrupted power supply (UPS)/ battery backups, and generators.
c. Alternate Routing Paths: Designing redundant cable pathways to prevent
single points of failure, ensuring continuous connectivity even in case of fiber cuts
or infrastructure damage.
d. Disaster Recovery Plans: Implementing automated failover mechanisms to
restore network swiftly after failures.
v. Smart Building Integration
Smart buildings integrate IoT-enabled sensors, automation, and AI-driven
management systems to enhance connectivity performance, energy efficiency, and
security. Key aspects include:
a. Smart network monitoring: Using AI-powered network analytics to detect
anomalies, optimize bandwidth allocation, and proactively resolve connectivity
issues.
b. Energy efficient networking: Utilizing power-saving features in network
devices and employing smart energy management systems to reduce operational
costs and environmental impact.
c. Integration with Smart Building Management Systems (BMS): Enabling
real-time control of network operations through a centralized BMS for efficient
fault detection and system management.
vi. Future Proofing
Properties must be designed with future-ready digital connectivity infrastructure to
support emerging technologies and next-generation network advancements. Future-
proofing measures include:
a. 5G ready infrastructure: Deploying fiber-based backhaul and small cell
solutions to accommodate 5G deployment within buildings.
12
2b. Edge computing integration: Ensuring support for edge data centers within
properties to minimize latency and improve data processing for smart applications,
AR/VR, and AI-driven analytics.
c. IPv6 adoption: Implementing IPv6-compliant networks to accommodate the
growing number of connected devices and ensure future scalability.
10.2. Integration of Connectivity Infrastructure in Design and Construction
To achieve seamless integration of digital connectivity infrastructure in building design and
construction, following may be considered:
i. Pre-wiring for connectivity: Include dedicated ducts and cable trays for fiber,
ethernet, and power cables.
ii. Structured cabling standards: Adopt structured cabling solutions in compliance
with national standards of BIS, TEC, etc.
iii. Equipment rooms and space allocation: Allocate space for telecom equipment,
server rooms, and network operation centers within the building.
iv. Network equipment: Plan sufficient network equipment in common areas, lobbies,
workspaces, and residences to ensure seamless connectivity based on expected footfall
and traffic.
10.3. Collaboration with stakeholders
Property managers should collaborate with concerned stakeholders right from planning
stage to build resilient and future ready DCI in the properties and facilitate RoW permissions
for telecom, internet service providers and digital connectivity infrastructure providers to
deploy fiber and wireless solutions efficiently. Collaboration with end users and
understanding their needs is the best way to plan and deliver digital connectivity
infrastructure which meets the expectations.
12
312
411. Appendix
11.1. Frequently Asked Questions (FAQ)
i. What is the purpose of Digital Connectivity Rating for properties?
The Digital Connectivity Rating is an initiative by the Telecom Regulatory Authority of
India (TRAI) to assess and benchmark the quality of digital connectivity within
properties. The primary objective is to encourage property managers to build digitally
connected and future ready smart properties and assess whether properties are equipped
with robust digital infrastructure, enhancing user experience for tenants, residents, and
businesses.
ii. What is the regulatory framework for the rating system?
Digital Connectivity Rating is governed by the provisions in “Rating of Properties for
Digital Connectivity Regulations, 2024” and further follow-up orders or guidelines issued
by TRAI.
iii. What parameters are assessed in the rating process?
The rating system evaluates properties based on the rating criteria provided in the
regulations. Some of the key aspects assessed under the framework include:
i. Availability of Connectivity Options: Access to mobile networks
(2G/3G/4G/5G), Wi-Fi, fiber broadband, and private networks.
ii. Indoor Coverage Quality: Signal strength and coverage within the building,
including basements, elevators and floors.
iii. Digital Infrastructure Readiness: Deployment of in-building solutions (IBS),
distributed antenna systems (DAS), small cells and optical fiber backbones.
iv. Network and power Redundancy: Availability of backup connectivity and
power sources to ensure uninterrupted services.
v. Future-Readiness: Scalability and ease of integration with advanced
technologies, including 5G and IoT solutions.
iv. Who benefits from this rating system?
i. Property Managers: Gain recognition and competitive advantage by providing
high-quality digital infrastructure.
12
5ii. Consumers: Enjoy uninterrupted connectivity for work, entertainment, and
communication.
iii. Telecom Service Providers: Identify opportunities for infrastructure upgrades
and improved service delivery.
iv. Government Authorities and Regulators: Promote digital connectivity
infrastructure and ensure consumer trust and protection. The improved digital
connectivity further drives digital economy and business opportunities in the
country.
v. Is the Digital Connectivity Rating mandatory under TRAI regulations?
Currently, the rating system is voluntary. However, TRAI strongly encourages
participation by property developers and property owners, and telecom service providers
to plan digital connectivity in the real estate sector from its inception and get it rated
under TRAI rating framework.
vi. What types of properties are covered under the rating framework?
The rating framework applies to all property types, including:
i. Residential complexes
ii. Office spaces and commercial properties
iii. Malls and retail outlets
iv. Educational institutions
v. Healthcare facilities
vi. Airports
vii. Metro rail
viii. Stadiums and open spaces
vii. What challenges might property managers face in achieving higher ratings?
Property managers may encounter the following challenges:
i. Limited infrastructure for in-building solutions such as DAS or fiber backbone.
ii. High costs are associated with upgrading outdated systems.
iii. Difficulty in integrating services from multiple telecom service providers.
TRAI encourages collaborations between property managers and telecom providers to
overcome these barriers.
12
6viii. Are there incentives for properties that achieve higher ratings?
While there are no mandatory financial incentives outlined by TRAI, properties with
higher ratings benefit from enhanced marketability, tenant satisfaction, and alignment
with smart city goals. Property managers may also see more demand for digital connected
properties.
ix. How can property manager apply for the Digital Connectivity Rating?
On applications can be submitted through the process specified in TRAI’s guidelines.
Typically, this involves:
i. One time registration on rating platform
ii. Apply for rating of property and provide relevant details
iii. Choose the DCRA of your choice
iv. Submit the application
v. The rating process starts.
x. Where can I find TRAI’s official guidelines for the rating system?
TRAI’s regulation and orders/guidelines for the Digital Connectivity Rating framework
are available on its official website i.e. www.trai.gov.in.
xi. How does this initiative align with India’s telecom policy?
The rating system aligns with the objectives of the National Digital Communications
Policy (NDCP), 2018, which emphasizes:
i. Enhancing broadband penetration
ii. Promoting ICT readiness across sectors
iii. Ensuring affordable and reliable digital connectivity
By setting a rating framework for digital connectivity inside properties where more data
is used than at street or open areas, TRAI contributes broader goals of creating a digitally
inclusive society.
xii. How does the rating process promote innovation in building design?
By encouraging the integration of future-ready digital infrastructure, TRAI’s rating
system motivates property managers to adopt innovative solutions, such as:
i. Smart building technologies
12
7ii. Energy-efficient network equipment
iii. Seamless integration of IoT devices and 5G networks
This fosters a more competitive and technology-driven property development.
11.2. List of Applicable Standards and References
i. TRAI Regulation on Rating of Properties for Digital Connectivity,2024
ii. National Building Code, 2016 as amended from time to time.
iii. Addendum to Model Building Bye Laws (MBBL)
iv. Building Bye-laws applicable in the respective State/Union Territory
11.3. Documents Checklist
Master checklist of supporting documents from property manager to be recorded and uploaded
by Digital Connectivity Rating Agency (DCRA) as applicable depending upon the category of
property i.e. Category ‘A’ or Category ‘B’ is as follows:
Record
maintenance
S.
Criteria Sub Criteria Supporting document evidence requirement
No.
(Upload/
DCRA level)
Approved DCI design documents by Record and
1
Approved competent authority Upload
Digital
Design compliance with MBBL and
2 Connectivity Record
Compliance to NBC standards
Infrastructure
Applicable
(DCI) design Design drawings certified by
3 Model Record
competent authority
Building Bye
Laws (MBBL) As-build DCI is as per approved Record and
4
and National design Upload
Building Code
Record and
5 (NBC) for
DCI
Photographs of DCI
Upload
implementation
Digital
as per approved
Connectivity Site inspection reports for DCI with
6 Record
DCI design
design comparisons
Testing and Commissioning
7 Record
certificates for DCI as applicable
Provision in Provision for Building layout plans for DCI or ICT Record and
8
Civil expansion of infrastructure duly marked and Upload
12
8Record
maintenance
S.
Criteria Sub Criteria Supporting document evidence requirement
No.
(Upload/
DCRA level)
Infrastructure, telecom rooms signed by DCRA and property
over and and cable manager
above MBBL pathways
and NBC Expansion feasibility reports – DCI
9 requirements, or ICT infrastructure pathways and Record
for Ensuring telecom rooms
Robust Digital
Provision for
10 Connectivity Updated network diagrams Record
expansion of
mobile and
wireline
11 Future expansion plans Record
connectivity
Site photos showing maintenance
12 Ease of access Record
pathways
of DCI installed
for repair or
13 maintenance Maintenance checklists Record
14 Power layout diagrams Record
Redundancy of
Provision in power source
15 Load switchover testing reports Record
Power
Infrastructure,
Electrical system line diagram
over and
16 including redundant input sources Record
above MBBL
and UPS system(s)
or NBC
Whether all key DCI systems
requirements,
17 affecting service availability are on Record
for Ensuring UPS power
UPS?
Reliable backup for DCI
Whether UPS system has
18
Digital
Record
redundancy?
Connectivity
UPS switch over successfully tested
19 Record
during sample testing?
12
9Record
maintenance
S.
Criteria Sub Criteria Supporting document evidence requirement
No.
(Upload/
DCRA level)
Whether duration of UPS backup
20 matches with available test reports Record
with full DCI load?
Monitoring system high level Record and
21
diagram Upload
Power
Capture monitoring system Record and
22 continuity
dashboard screenshot Upload
monitoring
Record and
23 Monitoring system diagram
Upload
24 BMS system architecture diagrams Record
Test report on DCI power systems,
25
Building
fire alarms and HVAC integration Record
Management
with BMS
System
Sample test report on detection and
notification of main power supply
26 Record
failure and takeover by
generator/UPS for DCI
Ducts layout diagrams from different
27 Record
Availability of external entry points for fiber/ DCI
alternate entry
paths for digital
Digital connectivity
Connectivity infrastructure Pathway layout diagrams from ducts
28 Record
Infrastructure to telecom room(s) for fiber/ DCI
Resilience
Non-flooding Whether DCI/telecom room(s) are
29 measures for above ground floor as per design and Record
DCI installation implementation?
13
0Record
maintenance
S.
Criteria Sub Criteria Supporting document evidence requirement
No.
(Upload/
DCRA level)
Whether key power systems like
UPS/ Generators for DCI are
30 Record
installed on ground or higher floor
with non-flooding consideration?
Whether drainage system is
31 Record
implemented as per design layout?
Whether DCI is supported with
32 redundant power sources Record
(Generator/UPS)?
Whether power system network
33 layout for DCI is implemented with Record
path diversity?
Implementation
of redundancy
in power source
Whether sample test reports
34
and DCI paths
Record
demonstrate testing of redundancy?
Whether path diversity for fiber and
other cables (DTH/ethernet as
applicable) across the building
35 Record
blocks, basements and towers from
digital connectivity infrastructure
room(s) is implemented?
Future Availability of
Readiness of the latest Whether the equipment installed
36 Digital generation of supports the latest generation of Record
Connectivity mobile mobile connectivity?
Infrastructure connectivity
13
1Record
maintenance
S.
Criteria Sub Criteria Supporting document evidence requirement
No.
(Upload/
DCRA level)
Photographs of installed latest
37 generation mobile connectivity Record
equipment
Bill of Material (BoM) installed at
38 building along with datasheets for Record
Support for relevant equipment
future bands Whether DCI supports future bands
39 for mobile or Wi-Fi network as Record
applicable as per datasheets?
Upgradability of existing wireline
DCI equipment’s
40 Record
(switches/routers/splitters/PON
Upgradability
etc.) and relevant cables
of wireline DCI
Whether the bandwidth supported
41 through optical fiber with speed 1 Record
Gbps or higher?
Backhaul fiber
42 Fiber testing results Record
connectivity
(service
Photographs of fiber termination Record and
43
provider to
point at main telecom room Upload
property)
Fiber layout diagrams up to user Record and
44
Provision of Fiber
premises Upload
Wired connectivity till
Sample fiber test reports confirming Record and
45
Connectivity user premises
connectivity to each user premise Upload
Infrastructure
Fiber Network layout diagram for user
46 Record
connectivity in units showing fiber terminations
each room or
office or
Sample test reports for fiber Record and
47
commercial
terminations testing Upload
space
Number of Telecom/Internet Service Provider
48 Record
wireline (ISP) Agreements
13
2Record
maintenance
S.
Criteria Sub Criteria Supporting document evidence requirement
No.
(Upload/
DCRA level)
Internet Service
Network integration certificates/test
49 Record
providers
reports
having
integration with
50
Digital
Service subscription status Record
Connectivity
Availability of Infrastructure
Service Number of
RF coverage map in the property or Record and
51
Providers Mobile Service walk/drive test results Upload
providers
Network performance test results
52 having coverage Record
from multiple operators
or integration
with Digital Agreements signed with Telecom
53 Connectivity Service Providers (without Record
Infrastructure commercial details)
Record and
54 RF coverage map of public areas
Upload
Mobile network
coverage and
performance in
public areas of
property
Service Speed test logs and call quality Record and
55
Performance reports Upload
Secure public
Wi-Fi network
coverage and Wi-Fi coverage maps and speed test Record and
56
performance in results Upload
public areas of
property
13
3Record
maintenance
S.
Criteria Sub Criteria Supporting document evidence requirement
No.
(Upload/
DCRA level)
Record and
57 Wi-Fi security audit reports
Upload
Record and
58 RF coverage map of areas under test
Upload
Mobile network
coverage and
performance in
non-public
areas
Speed test logs and call setup and Record and
59
call quality reports Upload
60 Wi-Fi security certifications Record
Secure public
Wi-Fi network
coverage and
performance in
non-public
areas
Wi-Fi coverage maps and speed test Record and
61
results Upload
13
4Record
maintenance
S.
Criteria Sub Criteria Supporting document evidence requirement
No.
(Upload/
DCRA level)
Average
download speed
of different
wireline Record and
62 Speed test results with timestamps
network(s) in Upload
respective
highest speed
plan
User feedback
User on digital User feedback logs from helpdesk Record and
63
Experience connectivity systems Upload
experience
13
511.4. User Feedback Form
This form is to evaluate the feedback of end user/ consumer on digital connectivity
experience in the property. Your feedback will help in assessing the level of digital
connectivity inside the property for award of Star rating under TRAI regulations.
(a) Name of property: __________, (b) URIN (As per rating portal):_________
(c) Type of property: ☐ Residential ☐ Commercial ☐ Government Properties
☐ Shopping malls ☐ Convention Centre ☐ Hospitality
(To be filled by DCRA)
Kindly provide your feedback on the scale of 1-5 by writing relevant number in the box
against respective questions. Score 1 (poor) being the lowest, 2 (average), 3 (good),
4 (very good) and 5 (Excellent) being the highest.
Provide rating
between 1 to 5
1. Mobile Service Performance
i. How would you rate your mobile voice call experience?
ii. Are you satisfied with mobile internet performance?
2. Broadband Service Performance
i. How would you rate the ease of provisioning of new broadband
connections?
ii. How satisfied are you with the speed of the internet connection?
iii. How will you rate the resolution mechanism?
3. Mobile Network Coverage
i. How would you rate the wireless network coverage in indoor spaces?
ii. How would you rate the wireless network coverage in outdoor areas?
4. Overall Experience
i. How would you rate the overall digital connectivity at this property?
5. Suggestions for Improvement
Signature of the end user/ consumer Signature of DCRA representative
Name :
Mobile No. :
Email-ID :
13
611.5. Template for declaration of maximum chargeable fee by DCRA (As per
regulation)
The below table covers the template for declaration of maximum chargeable fee by Digital
Connectivity Rating Agency (DCRA) as per the Section – I “Code of Conduct for DCRAs”
clause (vii) “Clear fee structure” in the “Rating of Properties for Digital Connectivity
Regulations, 2024”:
Maximum
Built up Area
Category Type of chargeable
S. in sq.ft./
Classification or Property fee by
No. length in km
Group DCRA
(in ₹)
50,000 -
100,000 sq.ft.
Apartments,
>100,000 -
independent
500,000 sq.ft.
1. Residential A houses, gated
>500,000 -
communities or
1000,000 sq.ft.
societies, etc.
>1000,000
sq.ft.
All properties of 50,000 -
the Central 100,000 sq.ft.
Government, the >100,000 -
State Government, 500,000 sq.ft.
Government
2. A Courts, Public >500,000 -
Properties
Sector 1000,000 sq.ft.
Undertakings,
>1000,000
Local Bodies,
sq.ft.
Heritage Sites, etc.
Commercial office 50,000 -
complex, shopping 100,000 sq.ft.
malls, industrial >100,000 -
Commercial estates, SEZs, 500,000 sq.ft.
3. A
Establishments multi-modal >500,000 -
logistic parks, 1000,000 sq.ft.
convention >1000,000
centres, etc. sq.ft.
Airport, Bus 50,000 -
Other private Station, Railway 100,000 sq.ft.
4. B
or public areas Station, Hospitals, >100,000 -
Hotels, 500,000 sq.ft.
13
7Maximum
Built up Area
Category Type of chargeable
S. in sq.ft./
Classification or Property fee by
No. length in km
Group DCRA
(in ₹)
Educational >500,000 -
Institutions, etc. 1000,000 sq.ft.
>1000,000
sq.ft.
50,000 -
Stadiums or 100,000 sq.ft.
Stadiums or
permanent spaces >100,000 -
Sport Arenas or
of gathering with 500,000 sq.ft.
5. spaces of B
seating capacity of >500,000 -
frequent
more than 5000 1000,000 sq.ft.
gathering
persons >1000,000
sq.ft.
Expressways,
100-500 km
Transport Highways,
6. B >500-1000 km
corridors Railways routes,
etc. >1000 km
13
8